TECH LIBRARY 1 SVPP Supplier Manuals Axiomatic corr datasheet current-converter IC DR 11.pdf

PDF 53 KB Posted

Attached to
Launch Operations Support Contract (LOSC) Request for Proposal (RFP) – FINAL
Solicitation number
FA4610-22-R-0001
Issued by

About this file

This Request for Proposal (RFP) solicits offers for the Launch Operations Support Contract (LOSC) to provide services at Vandenberg Air Force Base, California. The 30th Space Wing is seeking a contractor to support launch operations through tasks such as processing payloads and space vehicles; operating and maintaining facilities, systems, and ground support equipment; and providing engineering analysis, planning, and reporting. Responses are due no later than January 27, 2022. The North American Industry Classification System code for this effort is 561210 for Facilities Support Services. The estimated period of performance is a one-year base period with four one-year options. The RFP includes attachments outlining technical requirements, security specifications, labor standards, and contract data requirements.

View the file

Other files

File Type Posted
L-5_Section M dtd 19Nov21_Revised_30Aug22.pdf PDF
L-4_Section L dtd 19Nov21_Revised_30Aug22.pdf PDF
Solicitation Amendment FA461022R00010005 SF 30.pdf PDF
L-1_Contractor Staffing Plan and Matrix_30Aug22.xlsx XLSX spreadsheet
Conformed Solicitation Amendment - FA461022R00010005.pdf PDF
TECH LIBRARY Workload Data Information for CLINs X003_X004.docx DOCX document
L-4_Section L dtd 19Nov21_Revised_04Feb2022.pdf PDF
L-5_Section M dtd 19Nov21_Revised_04Feb2022.pdf PDF
L-5_Section M dtd 19Nov21_Revised_02Feb2022.pdf PDF
RFP Amendment 0004 Conf SF33 - FA461022R00010004.pdf PDF
RFP Amendment 0004 FA461022R00010004 SF30 signed 20220204.pdf PDF
L-4_Section L dtd 19Nov21_Revised_02Feb2022.pdf PDF
RFP Amendment 0003 Conf SF33 - FA461022R00010003.pdf PDF
RFP Amendment 0003 FA461022R00010003 SF30 signed 20220125.pdf PDF
L-4_Section L dtd 19Nov21_Revised_18Jan2022.pdf PDF
RFP Amendment - FA461022R00010002 Conf SF33 20220118.pdf PDF
RFP Amendment - FA461022R00010002 SF30 signed 20220118.pdf PDF
Amend 0001 Conformed SF33 - FA461022R00010001_20220112.pdf PDF
Atch 11 Appendix B - Wage Rate Tables (2019-2024)_Redacted_12Jan2022.pdf PDF
Atch 9 SCA WD 2015-5647_Rev 13_20211020_12Jan2022.pdf PDF
Atch 1_LOSC PWS_dtd 07Jan2022_Final_rev1.pdf PDF
Atch 7 DB WD CA20210018_Mod 28_20211203_12Jan2022.pdf PDF
Solicitation Amendment FA461022R00010001_20220112(S).pdf PDF
Atch 11 CBA-2019-12949_12Jan2022.pdf PDF
Atch 11 2019-2024 CBA_Redacted_w_Appendix A_12Jan2022.pdf PDF
L-4_Section L dtd 19Nov21_Revised_10Jan2022.pdf PDF
Atch 2_Appendix A_Property and Equipment Responibility List_Final_6Jan2022.xlsx XLSX spreadsheet
Atch 8 SCA WD 2015-5637_Rev 19_20211020_12Jan2022.pdf PDF
L-5_Section M dtd 19Nov21_Revised_11Jan2022.pdf PDF
L-2_SubcontractTeamingPartnerConsent_Revised_11Jan2022.pdf PDF
Atch 10 SCA WD 1986-0431 Rev 54_20210219_12Jan2022.pdf PDF
Atch 11 Appendix D - Job Descriptions_redacted_11Jan2022.pdf PDF
Atch 6_LOSC_DD254_7Jan2022.pdf PDF
Atch 2_Appendix J_Contract Data Requiremetns List (CDRL) Deliverables dtd 07Jan22_Final.pdf PDF
Atch 12 DB WD CA20210014_Mod 14_20211029_12Jan2022.pdf PDF
TECH LIBRARY 0 List of documents_Tech Ref Library_07Jan2022.pdf PDF
22R0001 LOSC RFP QandA Consolidated.pdf PDF
TECH LIBRARY 14-CES operations support_Template.pdf PDF
TECH LIBRARY 2-8310-PV-181-VTE-20210225.pdf PDF
Exhibit A_CDRL_A019_Cost Peformance Report_Final_9Dec2021.pdf PDF
Atch 11 2019-2024 CBA_Redacted_w_Appendix A.pdf PDF
Exhibit A_CDRL_A006_Technical Report Waster Water Discharge_Final_9Dec2021.pdf PDF
Exhibit A_CDRL_A012_Requisition Summary_Final_9Dec2021.pdf PDF
Exhibit A_CDRL_A011_Quality Management Plan_Final_9Dec2021.pdf PDF
Exhibit A_CDRL_A005_Fugitive Hydrocarbons Report_Final_9Dec2021.pdf PDF
TECH LIBRARY 7-PPAFS Business Plan.pdf PDF
Exhibit A_CDRL_A022_Accident Incident Report_Final_9Dec2021.pdf PDF
TECH LIBRARY 9-TA rollup WLF.pdf PDF
TECH LIBRARY 1 SVPP Supplier Manuals EthosEnergy Speed Input Module II User Manual.pdf PDF
Exhibit B_LOSC_DID_Combined_9Dec2021.pdf PDF
Show 40 more

Latest 50 of 137 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Axiomatic Technologies Corporation 5915 Wallace Street, Mississauga, Ontario Canada L4Z 1Z8

TEL: (905) 602-9270 x225 FAX: (905) 602-9279 E-mail: sales@axiomatic.com www.axiomatic.com

TECHNICAL DATASHEET #TD2300AX

4-20 mA to Current Converter P/N: IC-DR-XX and AX130300

Where xx = 11 (0-200 mA output) 12 (20 – 160 mA output)

14 (0-50 mA output) 18 (40-160 mA output) 20 (0-100 mA output) 24 (0-160 mA output)

25 (20-200 mA output) AX130300 (5-195 mA output)

Description: The Current Converter accepts a 24VDC power supply (nominal) and a 4-20mA input signal converting it to a current output. Various outputs are available, including 0-200 mA, 20-200 mA, 5-195 mA, 0-100 mA, 20-160 mA, 40- 160 mA, 0-160 mA or 0-50 mA. Span and zero is user adjustable. A diagnostic LED indicates operational status, glowing green when the load, input signal and power supply are connected. The load should be floating, isolated from ground. The circuit board is conformal coated and the unit is available in a 35 mm DIN rail mount housing.

Application:

Industrial automation Power generation controls

Technical Specifications:

Typical at nominal input voltage and 25 degrees C unless otherwise specified

Ordering Part Number: IC-DR-xx 4-20 mA to Current Converter Where xx = Output current default setting xx = 11 (0-200mA output) xx = 12 (20-160mA output) xx = 14 (0-50 mA output) xx = 18 (40-160 mA output) xx = 20 (0-100 mA output) xx = 24 (0-160 mA output) xx = 25 (20-200 mA output) AX130300: 4-20 mA input, 5-195 mA output

Input Specifications:

Current Input 4-20mA

TD2300AX 2

Output Specifications:

Current Output Factory settings +/- 2mA :

IC-DR-11 = 0-200mA IC-DR-12 = 20-160 mA IC-DR-14 = 0-50 mA IC-DR-18 = 40-160 mA IC-DR-20 = 0-100 mA IC-DR-24 = 0-160 mA IC-DR-25 = 20-200 mA AX130300 = 5-195 mA (Other current output ranges are available on request.)

Connect output to Output positive terminal and not to GND.

Response Time <5 mSec.

Non-linearity <0.1% without adjustments performed General Specifications:

Power Supply 24VDC nominal (9-45VDC operating range)

Transient protection is provided.

Power Consumption 550 milliwatts

All measurements taken at 24VDC, full output current (max.).

Reverse Polarity Protection Provided Operating Conditions -40 to 85 degrees C (-40 to 185 degrees F) Electrical Connection Screw terminals accept 14-24 AWG wire Enable (enables output through closing a mechanical relay contact)

To enable operation, externally short terminals 1 and 3.

Packaging and Dimensions (W x H x D)

DR12, Polycarbonate DIN rail mount (75 x 98.5 x 22.5 mm or 2.95 x 3.88 x 0.89 inches) for high profile DIN rail (35 mm)

Protection PCB conformal coated IP40 rated housing, Terminals rated at IP20

Weight 0.25 lbs. (0.11 kg)

Adjustments: Multi-turn trim pots (10 turns) Zero CW = increasing

Apply 4mA input current and adjust the Zero trimpot to desired minimum output current. Refer to the chart below.

Factory settings are listed below.

Span CW = increasing Apply 20mA input current and adjust the Span trimpot to desired maximum current output . Refer to the chart below.

Factory settings are listed below.

CW = clockwise, CCW = counter clockwise

Default Current Outputs and Adjustment Ranges:

MODELS IOUT MIN RANGE IOUT MAX RANGE DEFAULT DEFAULT

P/N MIN [mA] MAX [mA] MIN [mA] MAX [mA] MIN [+/-2 mA] MAX [+/-2 mA]

IC-DR-11 0 25 155 220 0 200

IC-DR-12 6 29 116 171 20 160

IC-DR-14 0 5 38 63 0 50

IC-DR-18 0.14 43.46 143 172 40 160

IC-DR-20 0 12 69 105 0 100

IC-DR-24 0.14 43.46 143 172 0 160

IC-DR-25 0 25 155 220 20 200

AX130300 0 25 155 220 15 195

TD2300AX 3

Specifications are indicative and subject to change. Actual performance will vary depending on the application and operating conditions. Users should satisfy themselves that the product is suitable for use in the intended application. All our products carry a limited warranty against defects in material and workmanship. Please refer to our Warranty, Application Approvals/Limitations and Return Materials Process as described on www.axiomatic.com/service.html.

Form: TD2300AX-04/14/10