T02 Ft Lauderdale FB BIS 2020 04 15.xls
XLS spreadsheet 73 KB Posted
- Attached to
- COMBINED SERVICES (OPERATIONS / MAINTENANCE & JANITORIAL RELATED SERVICES) Federal contract opportunity
- Solicitation number
- 47PE0721R0031
View the file
Other files for this federal contract opportunity
Show all 50
COMBINED SERVICES (OPERATIONS / MAINTENANCE & JANITORIAL RELATED SERVICES) has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| Location: | FORT LAUDERDALE FB/CH | Property Manager: | Mark Mueller | ||||||||
| Bldg. # | FL0089ZZ | 299 E. Broward Blvd | |||||||||
| Ft. Lauderdale, FL 33301 | |||||||||||
| Contract Specialist | Carolina McFaul | O & M Contractor | IEI | ||||||||
| General Information: | |||||||||||
| Quantity of Floors | 5 | Age of Building | 42 | Operating Hours | 7:00 am to 5:00 pm | ||||||
| Elevators | Building Operating Plan | Yes | Quantity of Agencies | 16 | |||||||
| Judges | 1 | ||||||||||
| Passengers | 4 | List Agencies *(Of special note are law enforcement and agencies with 24 hour operations)* | |||||||||
| Freight | 0 | Federal Protective Service (FPS) | |||||||||
| Prisoner | 1 | ||||||||||
| Total | |||||||||||
| Comments: | |||||||||||
| Child Care Centers | |||||||||||
| Interior: | |||||||||||
| Special Equipment | No | If yes, identify below: | |||||||||
| Playground | No | ||||||||||
| Environmental | |||||||||||
| GSA Owned Fuel Tanks | Qty. | Asbestos | Yes | ||||||||
| Above Ground | 1 | ||||||||||
| Under Ground | 0 | Lead Paint | No | ||||||||
| GSA Owned Generators | 1 | PCB's | No | ||||||||
| Firing Range | No | If yes, last date of lead clean up? | |||||||||
| Note to Contractor: | Asbestos, Lead, or any other hazardous material may be in the building (particularly older ones) and has not been discovered yet so all suspicious material found should be treated as such. | ||||||||||
| Major Alteration Project: | No | ||||||||||
| Comments: | |||||||||||
| Building Equipment | |||||||||||
| Building Automation System | |||||||||||
| Make | ANDOVER | Model | CONTINUUM | Software Version | VERSION 2.03 | ||||||
| Is BAS on GSA network? | No | Types of controller? | Pneumatics | ||||||||
| HVAC | |||||||||||
| Item | Qty | Item | Qty | Item | Qty | Item | Qty | ||||
| AHU | 13 | PIU | FCU | O | RTU | 2 | |||||
| VAV | 160 | OAF | VAV w Fan | RAF | |||||||
| Duct Heaters | |||||||||||
| Chillers | |||||||||||
| Qty. | 2 | ||||||||||
| Make | YORK | Model | YSBBCBS0-CFD | Serial # | SHHM-627350 | ||||||
| Evaporator Eddy Current Date | NA | Tonnage | 175 | Condenser Eddy Current Date | NA | ||||||
| Make | YORK | Model | YSBBCBSO-CFD | Serial # | SHHM-627480 | ||||||
| Evaporator Eddy Current Date | NA | Tonnage | 175 | Condenser Eddy Current Date | NA | ||||||
| Make | Model | Serial # | |||||||||
| Evaporator Eddy Current Date | Tonnage | Condenser Eddy Current Date | |||||||||
| Make | Model | Serial # | |||||||||
| Evaporator Eddy Current Date | Tonnage | Condenser Eddy Current Date | |||||||||
| UPS Systems | |||||||||||
| Qty. | 1 | Ownership | GSA | ||||||||
| Make | SQAURE D | Model | QOC16 | Serial # | NA | ||||||
| Make | Model | Serial # | |||||||||
| Make | Model | Serial # | |||||||||
| Domestic Water Heater | |||||||||||
| Qty. | 8 | Last Inspection Date | 3.13.2020 | ||||||||
| Make | S-46IL | Model | INSTA FLOW | Serial # | 173202 | Type | Electric | ||||
| Make | GE30T06AAG | Model | GE | Serial # | GE-0112B011129 | Type | Electric | ||||
| Make | RP40-2 | Model | RUUD | Serial # | RU-1278M136 | Type | Electric | ||||
| Make | 81V-300 | Model | RHEEM | Serial # | R-0792B06097 | Type | Electric | ||||
| Boilers | |||||||||||
| Qty. | 0 | Last Inspection Date | |||||||||
| Type | Make | Model | Serial# | ||||||||
| Type | Make | Model | Serial# | ||||||||
| Type | Make | Model | Serial# | ||||||||
| Type | Make | Model | Serial# | ||||||||
| Cooling Towers | |||||||||||
| Qty. | 2 | ||||||||||
| Make | MARLEY | Model | NA | Serial # | NC4001SP O51520-001-93A | ||||||
| Make | MARLEY | Model | NA | Serial # | NC4001SP 051520-002-93B | ||||||
| Make | Model | Serial # | |||||||||
| Generators | |||||||||||
| Building Load | 2019 | Last Load Bank Test | NA | Last Fuel Analysis | 2019 | ||||||
| Make | CUMMINS | Model | 680FDR5060FFW | Serial # | FH-90058-7711-3 | Gas | Diesel | ||||
| Fuel Capacity | 1000 | ||||||||||
| Make | Model | Serial # | Gas | Natural Gas | |||||||
| Fuel Capacity | |||||||||||
| Make | Model | Serial # | Gas | Natural Gas | |||||||
| Fuel Capacity | |||||||||||
| Fire Alarm System | |||||||||||
| Make | FCI | Model | E3 | Serial # | 1100-0458INCC BLACK | ||||||
| Device Count | |||||||||||
| Smoke Detector | 29 | Phoneline for Central Station Montoring | O&M Contractor | ||||||||
| Heat Detector | 1 | ||||||||||
| Duct Detector | 25 | Date of last annual test? | 9.7.2019 | ||||||||
| Pull Station | 54 | ||||||||||
| Water Flows | 10 | ||||||||||
| Tampers | 16 | ||||||||||
| Strobes | 58 | ||||||||||
| Speakers | 3 | ||||||||||
| Combo. Speaker / Strobes | 275 | ||||||||||
| Beam Detectors | NA | ||||||||||
| Batteries | 34 | ||||||||||
| Fire Sprinkler System | |||||||||||
| Wet | Yes | Date of last annual test? | 9.7.2019 | Date of last semi-annual test? | 3.28.2020 | ||||||
| Dry | Date of last annual test? | Date of last semi-annual test? | |||||||||
| Stand Pipe | Date of last annual test? | Date of last semi-annual test? | |||||||||
| Does building have a fire pump? | Yes | ||||||||||
| Specialize Fire Suppression Systems | |||||||||||
| FM-200 | No | Date of last annual test? | |||||||||
| CO2 | No | Date of last annual test? | |||||||||
| Inergen | No | Date of last annual test? | |||||||||
| Novec1230 | No | Date of last annual test? | |||||||||
| IG55 | No | Date of last annual test? | |||||||||
| Does building have a kitchen hood system? | No | ||||||||||
| Emergency Lights | |||||||||||
| How many battery operated emergency lights at facility? | 25 | ||||||||||
| Fire Extinguishers Types | |||||||||||
| Type | QTY. | ||||||||||
| Water | NA | How many require 12 year hydrostatic testing? | NONE | ||||||||
| A-B-C | 61 | ||||||||||
| B-C | 1 | ||||||||||
| CO2 | NA | ||||||||||
| K | NA | ||||||||||
| Security System | |||||||||||
| Card Readers | |||||||||||
| Make | IDENT | Model | IV | Qty. | 101 | ||||||
| Key Pads | |||||||||||
| Make | NA | Model | NA | Qty. | 35 | ||||||
| Parking Security Devices | |||||||||||
| Items | Qty. | Items | Qty. | Items | Qty. | ||||||
| Pop Up Bollard | NA | Wedge Plates | 2 | Judges Garage Doors | 0 | ||||||
| Building Garage Doors | 2 | Sally Ports | 1 | Building Gates | |||||||
| Plumbing | |||||||||||
| Back Flow Prevention Devices | Last Testing Date | 3.19.19 | |||||||||
| Qty. | 3 | ||||||||||
| Item | Qty. | Item | Qty. | ||||||||
| Automatic Soap Dispensers | NO | Outside Water Hoses Bibbs | 5 | ||||||||
| Automatic Towel Dispensers | NO | FDC Connections | 2 | ||||||||
| Automatic Flush Valves | 0 | Emergency Eye Wash Stations/ Showers | 2 | ||||||||
| Automatic Faucets | 35 | Hot Water Circulation Pump | NA | ||||||||
| Water Fountains with Filters | NO | Roof Drains | 33 | ||||||||
| Water Filters | NO | Outside Drains | 4 | ||||||||
| Building Ice Makers | NO | ||||||||||
| Grease Traps | NO | ||||||||||
| Decorative Water Fountains | Yes | ||||||||||
| Waterless Urinal | No | ||||||||||
| Make | Model | Qty. | |||||||||
| Make | Model | Qty. | |||||||||
| Roof System | |||||||||||
| What is the age of roof? | 5 Yrs | ||||||||||
| Warranty | 20YR | Warranty Holder | Soprema #101-011993 | ||||||||
| Does roof have anchorage point system installed? | No | ||||||||||
| If Yes, how many and what type? | |||||||||||
| Item | Qty. | ||||||||||
| Anchor Point | |||||||||||
| Davit Arms | |||||||||||
| Electrical System | |||||||||||
| Last thermal scan completion date? | 9.19.2019 | ||||||||||
| Has Arch Flash Study been completed? | No | If yes, what is the completion date? | |||||||||
| Last date of switchgear testing? | 11.26.2019 | ||||||||||
| Specialize Chemical Free Water Treatment System | No | ||||||||||
| If yes, what type of system is installed? | |||||||||||
| Warranty | Yes | Warranty Expiration Date | |||||||||
| Warranty Holder Information |