ST CLOUD VA BLDG. 51_103896_SET_B.pdf

PDF 493 KB Posted

Attached to
Y1DA--656-19-307 Remodel of Building 51-1, Eastside at the Saint Cloud VA, Saint Cloud, MN
Solicitation number
36C26325B0007_0003
Issued by

About this file

These technical drawings detail a ceiling lift system installation project for Room 111, Room 117, Room 124/125, and Room 127 at the St. Cloud VA Healthcare facility in Building 51. The documents specify precise installation requirements for Guldmann Inc. ceiling lift systems, including rail configurations, transformer specifications, and load capacities. Key technical specifications include system load testing at 1.5 times capacity (ranging from 825 lbs to 1650 lbs), electrical power requirements, and detailed mounting instructions for ceiling brackets and stabilizers.

The project documents outline critical installation notes, such as facility structure capacity requirements, electrical power source verification, and Guldmann's right to modify track layouts. The drawings provide comprehensive technical details for each room, including room dimensions, rail positioning, and specific installation guidelines. The project is identified with Project ID 103896, with recent revisions made in June 2024, including updates to backgrounds, top rail changes, and extended lift installations in specific rooms. The installation is part of a broader renovation of Building 51 at the St. Cloud VA Healthcare facility.

View the file

Other files

Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Guldmann Inc.

14401 McCormick Drive Tampa FL, 33626 Unit A

Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558

Email: Info@Guldmann.net

NOTES

APPROVED BY:

PROJECT NAME:

SHEET DESCRIPTION:

SHEET NO:

SIGNOFF / APPROVAL NOTES

1. The facility structure capacity must be able to support the load specified on the installation drawing.

2. Electrical power source provided by the facility, position to be verified in the field.

3. Guldmann Inc. reserves the right to slightly modify the track layout if necessary without Facility approval.

This includes lowering the system to avoid ceiling objects.

4. Guldmann Inc. will not be held responsible for any damages, inconvenience, resulting from hitting any non visible conduits during our installation process of which we have not been advised.

5. Modifications of door headers by the facility.

6. Signed drawings are required prior to ordering and installation of ceiling lifts.

This signature of each drawing confirms agreement of all the conditions listed above.

7. Systems are tested at 1.5 times capacity.

550 lbs. tested at 825 lbs.; 770 lbs. tested at 1155 lbs.; 825 lbs. tested at 1238 lbs.; 1100 lbs. tested at 1650 lbs.

MY SIGNATURE BELOW VERIFIES THAT I HAVE:

Reviewed all _____ pages, with a total quantity of _____ room(s), _____ system(s) for the approbation of layout for each room and the approbation of structure for each room.

CUSTOMER

APPROVAL: _____________________________________ DATE: _______________

DATE: DRAWN BY:

ACCURATE TO 4" BASED

ON PDF CONVERSION

St. Cloud VA Healthcare St. Cloud VA Bldg. 51 L1 East

4801 Veteran Dr.

St. Cloud, MN 56303

PROJECT ID:103896

St. Cloud VA Bldg. 51 L1 East

FACILITY SIGNOFF

GUL101

MGE01/24/2024

8 5 5

HOIST = 770 LBS1.

FLUSHED RECESSED / TYPE - P2.

CEILING HEIGHT = 8' - 0"3.

AFF TO DECK = 11' - 11"

ATTACHMENT TYPE =4.

CONCRETE BEAM

SPAN = 2' - 0"

Revision Schedule

Date Issued by Letter Description

06/02/2024 TRC A UPDATED BACKGROUNDS, MINOR ADJUSTMENTS TOP RAILS FOR WALL,DOOR

CHANGES

06/17/2024 MGE B EXTENDED LIFTS RM 111, RM 117, RM 127. UPDATED CHART. MATERIAL

EACH FIXED RAIL TO

HAVE x1 PARALLEL & x2 PERPENDICULAR

STABILIZERS

ALL JOINTS MUST HAVE x1 PARALLEL & x1

PERPENDICULAR STABILIZER

SEE SPAN CHART

S E

E S

P A

N C

H A

R T

SEE SPAN CHART

± 22°

STABILIZERS CAN BE ROTATED 180°

Fixed rail systems Fixed rail systems must be connected by Guldmann Service Team or by a qualified installer.

A Guldmann class I transformer must be used.

Installation to follow existing rules for authorized electricians and according to IEC/UL 60601-1.

Terminals on transformers Class I Double-insulated UL approved cable must be used (Cable specification: UL category: AVLV2, min.300V, min.

80° C, min. 18AWG (1 mm2 )) Transformer DK-13991 In:

Terminal 1 = N Terminal 2 = 100-115V AC Terminal 3 = 230V AC Terminal 4 = Protective ground Out:

Terminal 5 = 33V AC Terminal 6 = 33V AC

POWER TO BE WITHIN 15 FT OF END OF FIXED RAIL

Guldmann permanent mounted ceiling aluminium rail

Hoist with trolleys movable in rail

Protective Plast Enclosure

UL approved 400V cable, green, min. 14 AWG

Protective Ground

M1

UL approved 400V double isolated cable, min. 18 AWG

ON/OFF

UL approved 400V double isolated cable, min. 18 AWG

T ra n s fo rm e r

D K

-1

Main power Permanent installation Specification of breaker:

≥ 2.5 Amp capacity Line must always be broken

L1

AC/DC charger

Main Motor Control

Emergency Stop

Safety Circuit Emergency down

Motor Function Selector Switch0 1

V

A C

U

S

V

A C

P ro te c tiv e G ro u nd

V

A C

V

A C1 A

T

.5

A T

Green Light ON (or ON / OFF - sign)

Licensed Electrician to perform hardwire to transformer

B-RAIL

WEIGHT: 5.0 KG/M

(3.36 LBS/FT)

(2 1/2")

62 mm.

(5 m m

A

B

C

D

E

F

G

H

I

J

K

Ceiling bracket standard

A / B / C

Basic High M

Basic High M

Dimensions

205 mm

580 mm

345 mm

24 mm

58.5 / 125 / 170 mm

156 mm

184 mm

425 mm

2500 mm

970 mm

340 mm

8"

22.8"

13.5"

1.0"

2.2 / 4.9 / 6.6"

6.29"

7.2"

16.75"

98"

38"

13.3"

H

A

E D

F

C

G I

B

K J

SPRING PLATE

AVAILABLE FOR A & B RAIL

FLUSH CEILING PROFILE LIP IS 7/16" X 3/8"

CUT 12 - 15 MM OF THE 2 LONGITUDE

SCREW FOR

PROFILE END

LOAD LIMIT

KG LBS

CANTILEVER (SNGL)

MM INCHES

175 565 22 ¼

205 525 20 ½

255 485 19

275 485

300 455

350 445

375 425

400 425

SPAN (BETWEEN SUPPORTS)

MM INCHES

5500 215

5250 205

4750 186

4500 176

4000 157

3750 147

CANTILEVER (PAR)

MM INCHES

715 28

675 26 ½

635 25

630 24 ¾

605 23 ¾

595 23 ¼

SPAN CHART B-RAIL

16 ½

17 ¾

575 22 ½

22 ½16 ½

17 ¾

Guldmann Inc.

14401 McCormick Drive Tampa FL, 33626 Unit A

Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558

Email: Info@Guldmann.net

NOTES

APPROVED BY:

PROJECT NAME:

SHEET DESCRIPTION:

SHEET NO:

DATE: DRAWN BY:

St. Cloud VA Bldg. 51 L1 East

GEN. INFO

GUL102

MGE01/24/2024

PROJECT ID:103896

NTS

BRACING + SUPPORT

NTS

GH3 TRANSFORMER

HOIST = 770 LBS1.

FLUSHED RECESSED / TYPE - P2.

CEILING HEIGHT = 8' - 0"3.

AFF TO DECK = 11' - 11"

ATTACHMENT TYPE =4.

NTS

B-RAIL SPAN CHART / WEIGHT / DIMS

Revision Schedule

Date Issued by Number

06/02/2024 TRC A

06/17/2024 MGE B

CONCRETE BEAM

NTS

GH3 PATIENT SLING DIMS

SPAN = 2' - 0"

NTS

FLUSH CEILING PROFILE

40° T O 90°

0°

90°

1A B

8,9

DRAWINGS APPROVED FOR THE GULDMANN

GH-3 LIFTER SYSTEM STANDARD INSTALLATION

OF SUPPORT AND CONNECTION TO WAFFLE

DECK.

SYSTEMS INSTALLED FOR 770 POUNDS WILL BE

TESTED AT 1155 POUNDS.

V A

R

IE

S

M A

X

9,11

HVAC / MECH

BASEPLATE x4

STABILIZERS x3

STABILIZERS

± 22°

BRIDGE / RAIL TOP

BRIDGE SECTION

GULDMANN RAIL

SPAN

OPTIONAL B

DETAIL B

DETAIL A

OPTIONAL A

8,9

WAFFLE DECK / CONCRETE BEAM

DESCRIPTIONITEM NUMBERTAG

2-7/16" X 10' B2B STRUT SLOTTEDP5501-T1

3/8" B7 THREADED ROD1234602

STABILIZER BRACKET KIT - GULDMANN5504393

1" Ø-6013-T6 AL TUBE - GULDMANN550481-US4

CEILING BRACKET KIT - GULDMANN5504355

2 HOLE 90 DEG. BRACKETP10266

MQM-F WINGNUT 3/8"3778827

3/8" X 1-1/4" HEX BOLT4117648

3/8" X 1-1/4" X 1/8" WASHER (THICK)111012739

3/8" X 3-3/4" KB-TZ2 ANCHOR223145610

3/8" NYLOCK NUT113702411

3/8" BEVELLED WASHER3387312

3/8" HEX NUT41175213

MQZ-L BASEPLATE 3/8"37063214

MQA-F SADDLE NUT 3/8"37788515

( USED AS NEEDED )

( OPTIONAL )

MIN EMBEDMENT OF 2"

Guldmann Inc.

14401 McCormick Drive Tampa FL, 33626 Unit A

Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558

Email: Info@Guldmann.net

NOTES

APPROVED BY:

PROJECT NAME:

SHEET DESCRIPTION:

SHEET NO:

DATE: DRAWN BY:

SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS

St. Cloud VA Bldg. 51 L1 East

ATTACHMENT

GUL103

MGE01/24/2024

PROJECT ID:103896

HOIST = 770 LBS1.

FLUSHED RECESSED / TYPE - P2.

CEILING HEIGHT = 8' - 0"3.

AFF TO DECK = 11' - 11"

ATTACHMENT TYPE =4.

Revision Schedule

Date Issued by Number

06/02/2024 TRC A

CONCRETE BEAM

SPAN = 2' - 0"

GUL104

GUL104

/8

B .O

H

O

IS

T

/2

B .O

T

R A

V E

R S

E /L

IN

E

A R

R A

IL

C E

IL

IN

G

/8

B .O

C

O M

B I G

A T

E

/2

/8

17" MAX

/8

8" MIN

COMBI-BRACE

/2

/8

/4

/2

Guldmann Inc.

14401 McCormick Drive Tampa FL, 33626 Unit A

Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558

Email: Info@Guldmann.net

NOTES

APPROVED BY:

PROJECT NAME:

SHEET DESCRIPTION:

SHEET NO:

DATE: DRAWN BY:

SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS

St. Cloud VA Bldg. 51 L1 East

PROJECT DETAILS

GUL104

MGE01/24/2024

PROJECT ID:103896

HOIST = 770 LBS1.

FLUSHED RECESSED / TYPE - P2.

CEILING HEIGHT = 8' - 0"3.

AFF TO DECK = 11' - 11"

ATTACHMENT TYPE =4.

Revision Schedule

Date Issued by Number

06/02/2024 TRC A

CONCRETE BEAM

SPAN = 2' - 0"

3/4" = 1'-0"

TYP ELEVATION

1 1/2" = 1'-0"

CEILING / HOIST DETAIL

1 1/2" = 1'-0"

CEILING / COMBI-LOCK DETAIL

COMBI-LOCK

90 SF

142 SF

RESIDENT

ROOM

48 SF

111A

TOILET

ROOM

LINEN

A

90°L

/2

EQ EQ

/4

8' - 11 1/8" 1"

/8

7 1/4"

Guldmann Inc.

14401 McCormick Drive Tampa FL, 33626 Unit A

Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558

Email: Info@Guldmann.net

NOTES

APPROVED BY:

PROJECT NAME:

SHEET DESCRIPTION:

SHEET NO:

DATE: DRAWN BY:

SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS

ACCURATE TO 4" BASED

ON PDF CONVERSION

St. Cloud VA Bldg. 51 L1 East

RM 111

GUL105

MGE01/24/2024

PROJECT ID:103896

B rail

Ceiling bracket, Extended

Hoist

Stabilizers

KEY

Hoist Transformer

HOIST = 770 LBS1.

FLUSHED RECESSED / TYPE - P2.

CEILING HEIGHT = 8' - 0"3.

AFF TO DECK = 11' - 11"

ATTACHMENT TYPE =4.

CONCRETE BEAM

VERIFY SIZE AND LOCATION IN FIELD.

SPAN = 2' - 0"

1/2" = 1'-0"

RM 111

Revision Schedule

Date Issued by Number

06/02/2024 TRC A

06/17/2024 MGE B

54 SF

117A

TOILET

ROOM

142 SF

RESIDENT

ROOM

A

90°L

/8

1" 9' - 0 7/8"

EQ EQ

/8

/8

/4

3 3/4"

Guldmann Inc.

14401 McCormick Drive Tampa FL, 33626 Unit A

Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558

Email: Info@Guldmann.net

NOTES

APPROVED BY:

PROJECT NAME:

SHEET DESCRIPTION:

SHEET NO:

DATE: DRAWN BY:

SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS

ACCURATE TO 4" BASED

ON PDF CONVERSION

St. Cloud VA Bldg. 51 L1 East

RM 117

GUL106

MGE01/24/2024

PROJECT ID:103896

B rail

Ceiling bracket, Extended

Hoist

Stabilizers

KEY

Hoist Transformer

HOIST = 770 LBS1.

FLUSHED RECESSED / TYPE - P2.

CEILING HEIGHT = 8' - 0"3.

AFF TO DECK = 11' - 11"

ATTACHMENT TYPE =4.

CONCRETE BEAM

VERIFY SIZE AND LOCATION IN FIELD.

SPAN = 2' - 0"

1/2" = 1'-0"

RM 117

Revision Schedule

Date Issued by Number

155 SF

RESIDENT

ROOM

155 SF

RESIDENT

ROOM

64 SF

125A

TOILET

ROOM

64 SF

124A

TOILET

ROOM

A

A

GUL104

45°

45°

45°

45°

EQ EQ

5' - 3 1/4"

/8

/8

12' - 0" 10 1/4"

/4

/8

/8

EQ EQ

/8

10 1/4" 12' - 0"

5' - 3 1/4"

Guldmann Inc.

14401 McCormick Drive Tampa FL, 33626 Unit A

Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558

Email: Info@Guldmann.net

NOTES

APPROVED BY:

PROJECT NAME:

SHEET DESCRIPTION:

SHEET NO:

DATE: DRAWN BY:

SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS

ACCURATE TO 4" BASED

ON PDF CONVERSION

St. Cloud VA Bldg. 51 L1 East

RM 124 & 125

GUL107

MGE01/24/2024

PROJECT ID:103896

B rail

Ceiling bracket, Extended

Hoist

Stabilizers

KEY

Hoist Transformer

HOIST = 770 LBS1.

FLUSHED RECESSED / TYPE - P2.

CEILING HEIGHT = 8' - 0"3.

AFF TO DECK = 11' - 11"

ATTACHMENT TYPE =4.

CONCRETE BEAM

VERIFY SIZE AND LOCATION IN FIELD.

SPAN = 2' - 0"

1/2" = 1'-0"

RM 124 & 125

Revision Schedule

Date Issued by Number

FD

219 SF

127C

BATH

67 SF

127C

10' - 4 5/8" 1"

/8

2' - 10 3/8"

/8

/4

Guldmann Inc.

14401 McCormick Drive Tampa FL, 33626 Unit A

Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558

Email: Info@Guldmann.net

NOTES

APPROVED BY:

PROJECT NAME:

SHEET DESCRIPTION:

SHEET NO:

DATE: DRAWN BY:

SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS

ACCURATE TO 4" BASED

ON PDF CONVERSION

St. Cloud VA Bldg. 51 L1 East

RM 127

GUL108

MGE01/24/2024

PROJECT ID:103896

B rail

Ceiling bracket, Extended

Hoist

Stabilizers

KEY

Hoist Transformer

HOIST = 770 LBS1.

FLUSHED RECESSED / TYPE - P2.

CEILING HEIGHT =3.

AFF TO DECK = UNKNOWN

ATTACHMENT TYPE = UNKNOWN4.

CONCRETE BEAM

VERIFY SIZE AND LOCATION IN FIELD.

SPAN = 2' - 0"

1/2" = 1'-0"

RM 127

CURTAIN TO BE SPLIT OR5.

WALLMOUNTED SWING AWAY

Revision Schedule

Date Issued by Number

Sheets
GUL101 - FACILITY SIGNOFF
GUL102 - GEN. INFO
GUL103 - ATTACHMENT
GUL104 - PROJECT DETAILS
GUL105 - RM 111
GUL106 - RM 117
GUL107 - RM 124 & 125
GUL108 - RM 127

File details come from the government source that posted it. Updated .