DEPARTMENT OF THE ARMY

US ARMY INSTALLATION MANAGEMENT COMMAND

HEADQUARTERS, UNITED STATES ARMY GARRISON, AREA NORTH

UNIT #15543

APO AP 96224-5543

AMIM-YNC-PWF 9 February 2021

SPECIFICATIONS

FOR

PROJECT NO.: 243526

Repair barracks, building No. 827

Camp Casey, Korea

TABLE OF CONTENTS

1. Technical Provisions - I: Statement of Work

2. Technical Provisions - II: Technical Detail Specifications

3. Technical Provisions - III: Special Conditions

4. Appendix "A": List of Applicable Contract Drawings

5. Appendix “B”: List of materials for Material Approval Submittal

TECHNICAL PROVISIONS - I

STATEMENT OF WORK

PROJECT NO TITLE LOCATION

243526 Repair barracks, building No. 827 Camp Casey

1. DESCRIPTION: The work to be performed to repair barracks, building No. 827 is described below and executed by one or more of the groups.

1.1. Work by Contractor: The contractor shall provide all labor, tools, equipment, supplies and any other resources necessary to accomplish the scope of work contained herein as indicated in the drawings and in accordance with the specifications.

1.2. Work by In-House Labor: Not applicable to this project.

1.3. Work by Troop Labor: Not applicable to this project.

2. PRINCIPAL FEATURES: This project includes the following principal features:

2.1. Schedule #I, Repair (K): All work shall be in accordance with the attached drawings and specifications.

2.1.1. Civil Work

2.1.1.1. Replace sidewalk with new.

2.1.1.2. Replace concrete steps including handrail with new.

2.1.1.3. Replace ac surface course.

2.1.1.4. Paint 150mm thickness reflective white parking line.

2.1.1.5. Replace concrete curb with granite curb.

2.1.1.6. Replace barbeque kitchenette including shed with new.

2.1.1.7. Replace 20ea cherry blossom trees with new. Submit the certificate issued by a tree appraiser.

2.1.1.8. Remove fuel tank dike.

2.1.1.9. Restore solid sodding including top soil.

TP I-1

2.1.2. Architectural Work

2.1.2.1. Floor work

2.1.2.1.1. Replace existing floor tile and rubber tile with new Polyvinyl Chloride Tile (PVCT) including Vacuum Circuit Breaker (VCB) and Rubber Base (RB) as shown on new floor plan and interior finish schedule. The existing concrete flooring shall be smooth, true, level plane with all defects such as rough or scaling concrete, low spots, high spots, painting, and uneven surface shall have been corrected for new flooring. Provide leveling concrete for existing concrete slab with government approval.

2.1.2.1.2. Replace existing quarry tile including quarry tile base with new as shown on floor plans and interior finish schedule.

2.1.2.1.3. Replace existing Ceramic Mosaic Tile (CMT) with new including cement bond coat, waterproof membrane, mortar bed as shown on floor plans, section and details drawings.

2.1.2.1.4. Replace existing concrete slab at corridor, each bath rooms, toilet, laundry, and mud room on 1st floor for mechanical sewer line works as shown on floor plan and mechanical drawings.

2.1.2.1.5. Apply epoxy coating with non-slip grits on existing floors as shown on floor plan and interior finish schedule.

2.1.2.2. Interior and exterior wall work

2.1.2.2.1. Replace existing all Gypsum Wall Board (GWB) walls with new GWB walls

(Normal, Water resistant or 'X' type) including metal studs as shown on floor plans, sections and detail drawings.

2.1.2.2.2. Paint all existing interior walls including Concrete Masonry Unit (CMU), metal, concrete surfaces, stairway, hand rails, guard rails as shown on floor plan, detail drawings interior finish schedule.

2.1.2.2.3. Paint all existing exterior walls including Exterior Insulation and Finish System

(EIFS), CMU, metal, woods, concrete surfaces, stairwells, hand rails, guard rails, and other components (bicycle rack, trash bin) of exterior surface of the building as shown on floor plan, detail drawings and pictures.

2.1.2.2.4. Apply texture coating with plastering at multi-purpose room, dressing room and closet as shown on floor plans, elevations and interior finish schedule.

2.1.2.2.5. Replace existing Glazed Ceramic Wall Tile (GCWT, full height) with new including cement bond coats, water proof membrane, plastering w/metal lath and waterproof GWB as shown on floor plans and sections.

2.1.2.2.6. Replace existing pipe chases and pipe cover with new CMU, waterproof type

GWB pipe chases and metal cover including access door in each rooms for new mechanical piping system as per floor plans, sections and detail drawing.

TP I-2

2.1.2.2.7. Remove existing Acoustical Wall Panels (AWP) and apply texture coat on new

GWB in multi-purpose room, kitchen, lounge, and game room as shown on floor plan and interior finish schedule.

2.1.2.3. Interior and exterior ceiling and roof work

2.1.2.3.1. Replace existing ceiling with new acoustical ceiling tiles including metal suspension systems as shown on floor plans and interior finish schedule.

2.1.2.3.2. Replace existing ceiling with new GWB (Normal, Water resistant or 'X' type) ceiling including ceiling suspension system as shown on floor plans and finish schedule.

2.1.2.3.3. Paint all interior ceiling surfaces as shown on interior finish schedule and section.

2.1.2.3.4. Paint all existing exterior exposed metal, woods, fascia and soffit as shown on floor plan and elevations.

2.1.2.3.5. Apply acrylic fluid-applied waterproofing coating on existing roof as shown on floor plan and sections.

2.1.2.4. Miscellaneous work

2.1.2.4.1. Replace existing doors and door frames with new including hardware sets as shown on new floor plan and door schedule.

2.1.2.4.2. Replace existing windows including insect screen with new aluminum thermal breaker type windows including glass as shown on floor plans, elevations and window schedule.

2.1.2.4.3. Replace existing window horizontal mini blinds with new, fireproof type.

2.1.2.4.4. Replace existing wooden head, jam and sill for all windows with new as shown on door/window schedule. (Natural color, Oak)

2.1.2.4.5. Replace existing aluminum louver with new as shown on floor plans and louver schedule.

2.1.2.4.6. Replace existing Fire Extinguishers Cabinets (FEC) with new as shown on floor plans and detail drawing.

2.1.2.4.7. Replace existing all toilet accessories with new as shown on floor plans and detail drawings.

2.1.2.4.8. Replace existing all access doors on wall and ceiling with new as shown on floor plan and enlarged floor plan.

2.1.2.4.9. Replace existing kitchenette with new including base cabinet and upper cabinet as shown on floor plan, elevation and detail drawings.

2.1.2.4.10. Replace interior and exterior signages with new for all rooms as shown on floor plan, elevations and signage schedule.

2.1.2.4.11. Replace existing metal shelf with mop rack with new in janitor room.

2.1.2.4.12. Replace existing gravel bed and concrete curb with new 100mm deep gravel bed including granite curb around building as shown on floor plan and detail drawing.

TP I-3

2.1.2.4.13. Replace existing trench covers, hooks, and hose bib with new, and paint steel cover at mud room as shown on floor plan and detail drawing.

2.1.2.4.14. Replace existing al grating covers with new for each vest as shown on floor plan and detail drawing.

2.1.2.4.15. Replace existing counter top and Stainless Steel (SST) shelves with new at laundry as shown on floor plan and detail drawing.

2.1.2.4.16. Replace existing iron board cabinet with new as shown on floor plan and detail drawing.

2.1.2.4.17. Replace existing exterior and interior bulletin boards, card holder, and flexi info with new as shown on floor plan, detail drawing and signage schedule.

2.1.2.4.18. Replace existing aluminum louvers with new as shown on floor plans and detail drawings.

2.1.2.4.19. Replace wooden shelf, SST rod and drawer cabinet with new in each closet as shown on floor plan and details.

2.1.2.4.20. Replace existing fire rated access doors (1-1/2hrs) with new at laundry room and stairwell as shown on floor plans.

2.1.2.4.21. Replace existing wooden chair rails and wooden hanger rails at each bed room, kitchen, lounge and game room with new as shown on floor plans and detail drawings.

2.1.2.4.22. Replace existing vanity cabinets including wall hung cabinet with new in all dressing room as shown on new floor plans and detail drawing.

2.1.2.4.23. Replace existing concrete stoops with new as shown on floor plan.

2.1.2.4.24. Replace existing 18thk plywood shelves including plastic laminate at each storage bin as shown on floor plans and elevations.

2.1.2.4.25. Repair and block up damaged existing EIFS with new as necessaries.

2.1.2.4.26. Replace existing SST splash guards with new as shown on floor plans and exterior elevations.

2.1.3. Mechanical Work

2.1.3.1. Heating, Ventilating, and Air Conditioning (HVAC) system

2.1.3.1.1. Replace existing fan coil units, air conditioning units, room thermostat, control, accessories, and associated piping with new.

2.1.3.1.2. Replace existing supply air ducts, duct insulation, diffusers, registers, louvers dampers, grilles, and associated accessories with new.

2.1.3.1.3. Replace existing chilled and hot water circulation pump, air separator, expansion tank, chemical feeder, control system, and associated piping with new.

2.1.3.1.4. Replace existing all chilled and hot water main and branch-piping risers, insulation, ductwork, and accessories with new.

2.1.3.1.5. Replace all existing wall mounted exhaust fans, roof mounted exhaust fans, in-line exhaust fan, ceiling exhaust fans, control, and all associated ductwork with new.

TP I-4

2.1.3.1.6. Replace existing range hood, unit heaters, control, and all associated piping and ductwork with new.

2.1.3.1.7. Replace existing exhaust air ductwork, dryer vent, square diffusers, register, grilles, outside air intake louver, and outside air opening including motorized damper with new.

2.1.3.1.8. Perform Duct Air Leakage Test (DALT) and Testing, Adjusting, and Balancing

(T.A.B) after construction to verify if the HVAC system works properly.

2.1.3.1.9. Pre-air leaking test is required prior to repair infiltration and sealing at mechanical room. Repair infiltration and seal air leaking portions including clearance between wall ceiling and penetrators (duct, water piping, conduct pipe, flue vent pipe) at mechanical room. Provide final-air leakage test report.

2.1.3.2. Plumbing system

2.1.3.2.1. Replace existing hot water storage tank, domestic hot water circulation pump, domestic hot water recirculation pump, control system, and associated piping with new.

2.1.3.2.2. Replace existing domestic cold and hot water main and branch piping riser, insulation, backflow preventer assembly, floor drains, floor cleanouts, sewer piping, vent piping, and temperature mixing valve including accessories with new.

2.1.3.2.3. Replace all existing plumbing fixtures, electric water cooler, water hammer arrests, washer valve boxes, and associated piping with new.

2.1.3.3. Fire protection

2.1.3.3.1. Replace existing automatic fire protection sprinkler system and all associated accessories for fire protection system with new.

2.1.4. Electrical Work

2.1.4.1. Replace existing lighting fixtures, exit lights, exterior lights, toggle switches, photocell controls, hand-off-auto selector switches, lighting contactor, 3-way switches, dimmer switches, wires and conduits with new.

2.1.4.2. Replace existing receptacles including cover plates, watthour meter, circuit breakers, and associated wiring and conduits with new.

2.1.4.3. Replace existing safety switch, combination type motor starter, magnetic motor starters, manual motor starter, junction boxes, control system, wires and conduits for HVAC system with new.

2.1.4.4. Replace fire alarm control system with new addressable fire alarm control and mass notification system panel, manual pull station, smoke detector and relay module, building transmitter, antenna, visual signal strobes (75 candela), microphone, speaker device and local operating consoles, and associated wiring and conduit.

TP I-5

2.1.4.5. Replace existing telephone outlets with new.

2.1.4.6. Replace existing CATV cabinets, pull boxes, CATV outlets, and associated wire and conduit with new.

2.1.4.7. Remove and reinstall existing CCTV system, dome cameras. Replace CCTV wiring and conduit with new.

2.2. Schedule #II, New Construction (L): All work shall be in accordance with the attached drawings and specifications.

None

TP I-6

TECHNICAL PROVISIONS - II

TECHNICAL DETAIL SPECIFICATIONS

GENERAL: The specification sections listed below are applicable to this project. The specifications are from the “Standard Technical Specifications for O&MA Projects, Korea, Revision 1” (2014 OMA SPECS, REVISION 1), dated 20151030, located on the http://www.usfk.mil/Portals/105/Documents/Contracting/NewContract/2014-OMA-

SPECS_REVISION-1.pdf. The electronic version of the specifications is Acrobat® PDF format and can be read with the Acrobat Reader® software.

The Standard Technical Detail Specifications:

The work shall conform to the most current version of the listed standards/specifications below.

DIVISION 01 – GENERAL REQUIREMENTS

01 30 00 ADMINISTRATIVE REQUIREMENTS

01 32 01.00 10 PROJECT SCHEDULE

01 33 00 SUBMITTAL PROCEDURES

01 35 26 GOVERNMENTAL SAFETY REQUIREMENTS

01 45 00.00 10 QUALITY CONTROL

01 50 00 TEMPORARY CONSTRUCTION FACILITIES AND CONTROLS

01 58 00 PROJECT IDENTIFICATION

01 78 00 CLOSEOUT SUBMITTALS

01 78 23 OPERATION AND MAINTENANCE DATA

DIVISION 02 - EXISTING CONDITIONS

02 41 00 DEMOLITION AND DECONSTRUCTION

02 61 13 EXCAVATION AND HANDLING OF CONTAMINATED

MATERIAL

02 65 00 UNDERGROUND STORAGE TANK REMOVAL

02 81 00 TRANSPORTATION AND DISPOSAL OF HAZARDOUS

MATERIALS

02 82 14.00 10 ASBESTOS HAZARD CONTROL ACTIVITIES

TP II-1

http://www.usfk.mil/Portals/105/Documents/Contracting/NewContract/2014-OMA-SPECS_REVISION-1.pdf http://www.usfk.mil/Portals/105/Documents/Contracting/NewContract/2014-OMA-SPECS_REVISION-1.pdf

02 83 19.00 10 LEAD BASED PAINT HAZARD ABATEMENT, TARGET

HOUSING & CHILD OCCUPIED FACILITIES

DIVISION 03 – CONCRETE

03 11 13.00 10 STRUCTURAL CAST-IN-PLACE CONCRETE FORMING

03 15 00.00 10 CONCRETE ACCESSORIES

03 20 00.00 10 CONCRETE REINFORCING

03 30 00 CAST-IN-PLACE CONCRETE

DIVISION 04 – MASONRY

04 20 00 MASONRY

DIVISION 05 – METALS

05 50 13 MISCELLANEOUS METAL FABRICATIONS

DIVISION 06 - WOOD, PLASTICS, AND COMPOSITES

06 10 00 ROUGH CARPENTRY

06 20 00 FINISH CARPENTRY

DIVISION 07 - THERMAL AND MOISTURE PROTECTION

07 14 00 FLUID-APPLIED WATERPROOFING

07 24 00 EXTERIOR INSULATION AND FINISH SYSTEMS

07 60 00 FLASHING AND SHEET METAL

07 92 00 JOINT SEALANTS

DIVISION 08 – OPENINGS

08 11 13 STEEL DOORS AND FRAMES

08 14 00 WOOD DOORS

08 51 13 ALUMINUM WINDOWS

08 71 00 DOOR HARDWARE

08 81 00 GLAZING

08 91 00 METAL WALL AND DOOR LOUVERS

DIVISION 09 – FINISHES

09 22 00 SUPPORTS FOR PLASTER AND GYPSUM BOARD

TP II-2

09 22 36 LATH

09 29 00 GYPSUM BOARD

09 30 00 CERAMIC TILE, QUARRY TILE, AND PAVER TILE

09 51 00 ACOUSTICAL CEILINGS

09 65 00 RESILIENT FLOORING

09 90 00 PAINTS AND COATINGS

DIVISION 10 – SPECIALTIES

10 14 01 EXTERIOR SIGNAGE

10 14 02 INTERIOR SIGNAGE

10 21 13 TOILET COMPARTMENTS

10 28 13 TOILET ACCESSORIES

DIVISION 12 – FURNISHINGS

12 21 00 WINDOW BLINDS

12 32 00 MANUFACTURED WOOD CASEWORK

12 36 00 COUNTERTOPS

DIVISION 21 - FIRE SUPPRESSION

21 13 13.00 10 WET PIPE SPRINKLER SYSTEM, FIRE PROTECTION

DIVISION 22 – PLUMBING

22 00 00 PLUMBING, GENERAL PURPOSE

DIVISION 23 - HEATING, VENTILATING, AND AIR CONDITIONING

23 00 00 AIR SUPPLY, DISTRIBUTION, VENTILATION, AND EXHAUST

SYSTEMS

23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC

23 07 00 THERMAL INSULATION FOR MECHANICAL SYSTEMS

23 09 53.00 20 SPACE TEMPERATURE CONTROL SYSTEMS

23 52 00 HEATING BOILERS

23 64 26 CHILLED, CHILLED-HOT, AND CONDENSER WATER PIPING

SYSTEMS

23 82 02.00 10 UNITARY HEATING AND COOLING EQUIPMENT

TP II-3

DIVISION 26 – ELECTRICAL

26 00 00.00 20 BASIC ELECTRICAL MATERIALS AND METHODS

26 05 48.00 10 SEISMIC PROTECTION FOR ELECTRICAL EQUIPMENT

26 08 00 APPARATUS INSPECTION AND TESTING

26 20 00 INTERIOR DISTRIBUTION SYSTEM

26 51 00 INTERIOR LIGHTING

26 56 00 EXTERIOR LIGHTING

DIVISION 27 – COMMUNICATIONS

27 10 00 BUILDING TELECOMMUNICATIONS CABLING SYSTEM

27 54 00.00 20 COMMUNITY ANTENNA TELEVISION (CATV) SYSTEMS

DIVISION 28 - ELECTRONIC SAFETY AND SECURITY

28 31 33.00 10 FIRE ALARM REPORTING SYSTEM, RADIO TYPE

28 31 49 CARBON MONOXIDE DETECTORS

28 31 64.00 10 FIRE DETECTION AND ALARM SYSTEM, ADDRESSABLE

28 31 76 INTERIOR FIRE ALARM AND MASS NOTIFICATION SYSTEM

DIVISION 31 – EARTHWORK

31 00 00 EARTHWORK

DIVISION 32 - EXTERIOR IMPROVEMENTS

32 01 16.17 COLD MILLING OF BITUMINOUS PAVEMENTS

32 12 10 BITUMINOUS TACK AND PRIME COATS

32 12 11 BITUMINOUS SURFACE TREATMENT

32 12 16 HOT-MIX ASPHALT (HMA) FOR ROADS

32 92 23 SODDING

TP II-4

TECHNICAL PROVISIONS - III

SPECIAL CONDITIONS

1. Material Approval Submittal:

(1) The contractor shall submit a shop drawing submittal schedule and the material approval request with all supporting documents to the COR within 14 days after receipt of NTP.

(2) Attached list of materials in Appendix “B” shall be included in the shop drawing submittal schedule and material approval request.

2. The contractor shall have personnel on site for the sprinkler work and the fire alarm work upon Government's direction, who are certified by the National Institute for Certification in Engineering Technologies (NICET) Level III or equivalent. Equivalent Certificates in Korea are the followings which are issued by the Human Resource Development Service of Korea. If the contractor doesn’t have personnel who are certified by NICET, the contractor shall have two personnel that one is certified for (1) and the other for (2) below.

(1) Engineer Fire Fighting Facilities - Electrical (소방설비기사 -전기)

(2) Engineer Fire Fighting Facilities - Mechanical (소방설비기사 -기계)

3. Environmental Requirements in Contract

The Contractor shall perform work consistent with the relevant policy and objectives identified in Installation’s Environmental Management System (EMS). The Contractor shall perform work in a manner that conforms to all appropriate Environmental Management Programs and Operational Controls identified by Installation’s EMS, including pollution prevention, waste reduction, energy use, and natural resource protection. The Contractor shall provide monitoring and measurement information as necessary for the organization to address environmental performance relative to the environmental, energy, and transportation management goals. In addition, the Contractor shall advise their employees of their roles and responsibilities identified by the EMS and how these requirements affect their work performed under this contract. The Contractor is responsible for ensuring that the Contractor and any persons involved in the supervision or performance of the contract complete all required Environmental training.

TP III-1

In the event of any environmental nonconformance or noncompliance associated with the contracted services, the contractor shall take corrective and/or preventative actions. In the event of any noncompliance with any federal, state, or local environmental law, regulation or requirement, the Contractor shall immediately respond by taking all appropriate corrective actions and notifying the Contracting Officer’s Representative (COR) and the Environmental Office. For any nonconformance with the EMS, the Contractor shall take corrective action and initiate further preventative action, as required by the Environmental Office.

All on-site contractor personnel shall complete necessary safety and environmental training specified for the type of work conducted on-site. Upon contract award, the COR will notify the EMS Manager to arrange Environmental training for appropriate staff.

Additionally, when ordering supplies for use on Installation, all contractor personnel must favor energy-efficient, recycled or reclaimed material whenever practicable.

The responsibilities of all contractor personnel include:

(1) Comply with all applicable environmental laws, regulations and installation environmental policies.

(2) Control and prevent spills or hazardous substances releases IAW installation Spill

Prevention Plan.

(3) Ensure dust, debris, materials, trash, etc., do not become air borne and travel off the project site.

(4) Do not remove, cut, deface, injure, or destroy land resources including trees, shrubs, vines, topsoil and land forms without approval, except in areas indicated on the drawings or specified to be cleared.

(5) Monitor all water areas affected by construction activities to prevent pollution of surface and ground waters. Do not apply toxic or hazardous chemicals to soil or vegetation unless otherwise indicated.

(6) Open burning is prohibited on the Government premises IAW installation environmental policy.

(7) Participate in installation’s recycling program.

(8) Reducing the amount of hazardous material and/or solvent used by purchasing fewer hazardous materials and by increasing the use of products with recycled content. Spills of hazardous or toxic materials must be immediately reported to the Contracting Officer and the Environmental Office. Storage, describing, packaging, labeling, marking and placarding of hazardous waste and hazardous material IAW applicable environmental laws, regulations and local environmental policies. Transport hazardous waste off Government property and dispose of it in compliance with National, Provincial, and/or Local requirements for solid waste disposal.

TP III-2

(9) Reducing the amount of solid waste from construction and demolition debris, and scrap metal sent to municipal and rubble landfills by reducing, reusing, and recycling. Handling, storage, and disposal of solid waste must be conducted to prevent contamination.

Transport solid waste off Government property and dispose of it in compliance with National, Provincial, and/or Local requirements for solid waste disposal.

(10) Conserving energy and water usage by turning off lights and equipment when not in use and using only the necessary amount of water needed to complete the required tasks. Continuous conservation of our natural resources is a must.

(11) When potential cultural or historic items are inadvertently found during construction activities, immediately cease activities in the vicinity of the discovery and report the findings to the Environmental Office.

(12) Participate in installation’s Integrated Pest Management (IPM) program whenever practicable.

(13) Minimize interference with disturbance to, and damage to fish, wildlife, and plants including their habitat.

4. CONTRACT REQUIREMENTS PACKAGE ANTITERRORISM/OPERATIONS SECURITY

REVIEW COVER SHEET

After Notice to process is issued, COR shall take following action, Section IV. Standard Contract

Language/Contract Clause Applicability and/or Additional SOW Language.

A. AT Level I training. This standard language is for contractor employees with an area of performance within as Army controlled installation, facility or area. All contractor employees, including subcontractor employees, requiring access to Army installations, facilities, and controlled-access areas shall complete AT Level I awareness training within 30 calendar days after the contract start date or effective date of incorporation of this requirement into the contract, whichever is applicable. The contractor shall submit certificates of completion for each affected contractor employee and subcontractor employee, to the COR or to the contracting officer, if a

COR is not assigned, within 05 calendar days after completion of training by all employees and subcontractor personnel. AT Level I awareness training is available at the following website:

http://jko.jten.mil

B. Access and general protection/security policy and procedures. This standard language is for contractor employees with an area of performance within Army controlled installation, facility, or area. Contractor and all associated sub-contractors employees shall provide all information required for background checks to meet installation access requirements to be accomplished by installation Provost Marshal Office, Director of Emergency Services or Security Office. Contractor workforce must comply with all personal identity verification requirements (FAR clause 52.204-9, Personal Identity Verification of Contractor Personnel) as

TP III-3

http://jko.jten.mil/ directed by DOD, HQDA and/or local policy. In addition to the changes otherwise authorized by the changes clause of this contract, should the Force Protection Condition (FPCON) at any individual facility or installation change, the Government may require changes in contractor security matters or processes.

B-a. For contractors that do not require CAC, but require access to a DoD facility or installation. Contractor and all associated sub-contractors employees shall comply with adjudication standards and procedures using the National Crime Information Center Interstate Identification Index (NCIC-III) and Terrorist Screening Database (TSDB) (Army Directive 2014- 05/AR 190-13), applicable installation, facility and area commander installation/facility access and local security policies and procedures (provided by government representative), or, at OCONUS locations, in accordance with status of forces agreements and other theater regulations.

C. iWATCH Training. The contractor and all associated sub-contractors shall brief all employees on the local iWATCH program (training standards provided by the requiring activity ATO). This local developed training will be used to inform employees of the types of behavior to watch for and instruct employees to report suspicious activity to the COR. This training shall be completed within 30 calendar days of contract award and within 05 calendar days of new employees commencing performance with the results reported to the COR NLT 30 calendar days after contract award.

D. For contracts that require OPSEC Training. Per AR 530-1 Operations Security, the contractor employees must complete Level I OPSEC Awareness training. New employees must be trained within 30 calendar days of their reporting for duty and annually thereafter.

TP III-4

APPENDIX "A"

LIST OF APPLICABLE CONTRACT DRAWINGS

GENERAL: The work shall conform to the following contract drawings and OMA standard detail drawings, 2014 (dated 30 November 2015), issued by the Department of the Army, Installation

Management Agency, Korea Region Office and located on http://www.usfk.mil/Portals/105/Documents/Contracting/NewContract/STANDARD-DETAIL-

DRAWINGS-FOR-OMA-PROJECTS-KOREA_20151130.pdf, all of which form a part of the specifications.

Ring No. Sheet No. Description Date

1 T-1 TITLE SHEET-1 8 FEB 21

2 T-2 TITLE SHEET-2 8 FEB 21

CIVIL

3 C-1 LOCATION PLAN AND GENERAL NOTES 8 FEB 21

4 C-2 SITE LAYOUT PLAN AND SCOPE OF WORK 8 FEB 21

5 C-3 BARBEQUE KITCHENETTE SHED PLAN, SECTION

AND DETAILS

8 FEB 21

6 C-4 MISC. DETAILS - 1 8 FEB 21

7 C-5 MICS. DETAILS - 2 8 FEB 21

ARCHITECTURAL

8 A-1 1ST FLOOR PLAN AND GENERAL NOTES 8 FEB 21

9 A-2 2ND - 4TH FLOOR PLANS AND SCOPE OF WORKS 8 FEB 21

10 A-3 ELEVATIONS AND PICTURES 8 FEB 21

11 A-4 ELEVATIONS AND PICTURES 8 FEB 21

12 A-5 GENERAL SECTIONS 8 FEB 21

13 A-6 INTERIOR WALL SECTIONS-1 8 FEB 21

14 A-7 INTERIOR WALL SECTIONS-2 8 FEB 21

15 A-8 INTERIOR WALL SECTIONS-3 8 FEB 21

16 A-9 ENLARGED FLOOR PLANS AND FIRE RATED ACCESS

DOOR NOTES

8 FEB 21

17 A-10 INTERIOR ELEVATIONS-1 8 FEB 21

18 A-11 INTERIOR ELEVATIONS-2 8 FEB 21

A-1

19 A-12 CLOSET DETAILS 8 FEB 21

20 A-13 KITCHEN CABINET DETAILS & KITCHEN CABINET

NOTE

8 FEB 21

21 A-14 VANITY CABINET DETAILS, CHAIR RAIL DETAIL &

LAUNDRY COUNTER SECTION

8 FEB 21

22 A-15 DETAILS-1 8 FEB 21

23 A-16 DETAILS-2 8 FEB 21

24 A-17 DETAILS-3 8 FEB 21

25 A-18 DETAILS-4 8 FEB 21

26 A-19 DETAILS-5 8 FEB 21

27 A-20 INTERIOR, EXTERIOR FINISH SCHEDULE & FINISH

SCHEDULE NOTES

8 FEB 21

28 A-21 DOOR / WINDOW SCHEDULE, ELEVATIONS 8 FEB 21

29 A-22 HARDWARE SCHEDULE AND NOTES 8 FEB 21

30 A-23 SIGNAGES SCHEDULE 8 FEB 21

MECHANICAL

31 M-1 MECHANICAL MATERIAL INDICATIONS & SYMBOLS

AND ABBREVIATIONS

8 FEB 21

32 M-2 FIRE PROTECTION AND MECHANICAL GENERAL

NOTES, NOTES AND SCOPE OF WORK

8 FEB 21

33 M-3 EQUIPMENT SCHEDULE - 1 8 FEB 21

34 M-4 EQUIPMENT SCHEDULE - 2 8 FEB 21

35 M-5 HVAC PIPING PLAN (1ST FLOOR) AND NOTES 8 FEB 21

36 M-6 HVAC PIPING PLAN (2ND - 3RD FLOOR) AND NOTES 8 FEB 21

37 M-7 HVAC PIPING PLAN (4TH FLOOR) AND NOTES 8 FEB 21

38 M-8 HVAC PIPING SCHEMATIC DIAGRAM AND NOTES 8 FEB 21

39 M-9 MECH. ROOM PARTIAL PLAN AND NOTES 8 FEB 21

40 M-10 HVAC DUCT PLAN (1ST FLOOR) AND NOTES 8 FEB 21

41 M-11 HVAC DUCT PLAN (2ND-3RD FLOOR) AND NOTES 8 FEB 21

42 M-12 HVAC DUCT PLAN (4TH FLOOR) AND NOTES 8 FEB 21

43 M-13 MECH. ROOM DUCT PARTIAL PLAN, LAUNDRY ROOM

DUCT PARTIAL PLAN(1ST FL.) LINT FILTER DETAIL

AND NOTES

8 FEB 21

44 M-14 HOT/CHILLED WATER FLOW SYSTEM DIAGRAMN

AND AIR HANDLING UNIT SYSTEM CONTROL

DIAGRAM

8 FEB 21

45 M-15 HEAT/VENT SYSTEM CONTROL DIAGRAM 8 FEB 21

46 M-16 DOMESTIC HOT WATER SYSTEM CONTROL

DIAGRAM

8 FEB 21

47 M-17 PLUMBING PIPING PLAN (1ST FLOOR) AND NOTE 8 FEB 21

48 M-18 PLUMBING PIPING PLAN (2ND FLOOR) AND NOTE 8 FEB 21

49 M-19 PLUMBING PIPING PLAN (3RD FLOOR) AND NOTE 8 FEB 21

50 M-20 PLUMBING PIPING PLAN (4TH FLOOR) AND NOTE 8 FEB 21

A-2

51 M-21 BATH. RM. PLUMBING PIPING PARTIAL PLAN AND

NOTE

8 FEB 21

52 M-22 LAUNDRY & MUD RM PLUMBING PIPING PARTIAL

PLAN AND NOTE

8 FEB 21

53 M-23 LAUNDRY & MUD RM PLUMBING PIPING ISOMETRIC

DIAGRAM AND NOTES

8 FEB 21

54 M-24 MECH ROOM AIR LEAKAGE TEST FLOW CHART, AIR

BARRIERS AND QUALIFICATION OF AIR LEAKAGE

TESTING

8 FEB 21

55 M-25 FIRE PROTECTION LEGEND & ABBREVIATION,

AUTOMATIC FIRE SUPPRESSION GENERAL NOTES,

SPRINKLER Q'TY LIST AND NOTE

8 FEB 21

56 M-26 MECH ROOM FIRE PROTECTION PIPING PARTIAL

PLAN AND FIRE PROTECTION REQUIREMENTS

8 FEB 21

57 M-27 1ST FL. FIRE PROTECTION PIPING PLAN, AND

GENERAL NOTES

8 FEB 21

58 M-28 2ND & 3RD FL. FIRE PROTECTION PIPING PLAN 8 FEB 21

59 M-29 4TH FL. FIRE PROTECTION PIPING PLAN, 8 FEB 21

60 M-30 DETAILS-1 8 FEB 21

61 M-31 DETAILS-2 8 FEB 21

62 M-32 DETAILS-3 8 FEB 21

63 M-33 DETAILS-4 8 FEB 21

64 M-34 DETAILS-5 8 FEB 21

65 M-35 DETAILS-6 8 FEB 21

ELECTRICAL

66 E-1 LEGEND, GENERAL NOTES AND SCOPE OF WORK 8 FEB 21

67 E-2 1ST FLOOR LIGHTING PLAN AND 2ND-4TH FLOOR

LIGHTING PLAN

8 FEB 21

68 E-3 LIGHTING FIXTURE DETAILS 8 FEB 21

69 E-4 LIGHTING FIXTURE SCHEDULE & PHOTOCELL

CONTROL DIAGRAM

8 FEB 21

70 E-5 1ST FLOOR POWER PLAN AND 2ND-4TH FLOOR

POWER PLAN

8 FEB 21

71 E-6 EXISTING PANELBOARD "A", "B", "C", "D", "E" & "F"

CONN. DIAGRAM

8 FEB 21

72 E-7 EXISTING PANELBOARD "G", "H", "I", "J" & "M" CONN.

DIAGRAM

8 FEB 21

73 E-8 POWER ONE LINE DIAGRAM 8 FEB 21

74 E-9 1ST FLOOR F/A & MNS PLAN AND 2ND-4TH FLOOR

F/A & MNS PLAN

8 FEB 21

75 E-10 NEW FIRE ALARM/MASS NOTIFICATION SYSTEM

DIAGRAM

8 FEB 21

A-3

76 E-11 1ST FLOOR TEL/TV PLAN AND 2ND-4TH FLOOR

TEL/TV PLAN

8 FEB 21

77 E-12 CATV SYSTEM RISER DIAGRAM 8 FEB 21

78 E-13 1ST FLOOR CCTV PLAN AND 2ND-4TH FLOOR CCTV

PLAN

8 FEB 21

79 E-14 CCTV SYSTEM DIAGRAM 8 FEB 21

80 E-15 TYPICAL MODULE ELEC. PLAN-A & B MECH. RM

PARTIAL POWER PLAN

8 FEB 21

A-4

APPENDIX "B"

List of materials for Material Approval Submittal

Submittal Identification

Description of Submittal

LC-1 Ready Mixed Conc. 240kg/cm2

LC-2 Steel Bar Reinforcing

LC-3 Base Course

LC-4 Hot mixed Asphalt Concrete #67

LC-5 #8-150x150 WWF

LC-6 Granite Curb

LC-7 CHERRY BLOSSOM TREE CERTIFICATE

LA-1 Concrete masonry block 8"

LA-2 Cement portland, 40KG

LA-3 Granite curb stone, 200Wx300Dx1,000L

LA-4 Ready mixed concrete, 210kg/CM, slump 12

LA-5 Joint sealant for expansion joint

LA-6 Wire welding fabric, 150x150, #8 x #8

LA-7 Vapor barrier, 0.1mm

LA-8 Metal lath

LA-9 Waterproofing wall & floor membrane

LA-10 Anodized AL blast door w/ AL frame & insulated glasses, HDW, 1714 x 2150

LA-11 Anodized AL door w/ AL frame & insulated glasses, HDW, 1714 x 2150

LA-12

Steel thermal insulated blast double door w/steel frame door size: 1,714 W X 2150 H X 44.5 Thk., 600 x 750 insulated glass

LA-13 Steel insulated thermal blast door with steel frame door size; 915W. X 2133H. X 44.5 Thk.

LA-14 Steel thermal insulated double door w/steel frame door size: 1,714 W X 2133 H X 44.5 Thk.

LA-15

Steel hollow core door, 1 hrs fire rate w/frame door size; 1066W. X 2133H. X 44.5 Thk. 100 X 600 insulated fire glass

LA-16 Steel hollow core door, 1 hrs fire rate w/frame door size; 1066W. X 2133H. X 44.5 Thk.

LA-17

Steel hollow core single door, 1/3 hrs fire door w/frame door size; 914W X 2133H. X 44.5 Thk.

LA-18

Wood solid core door w/frame door size; 914W X 2133H X 44.5 Thk. 1/3hrs fire rated & fixed steel window 600 x 750, fire rated glass

B-1

Description of Submittal

LA-19

Wood solid core double door w/frame door size; 1814W X 2133H X 44.5 Thk. 1/3hrs fire rated door W/600 X 750 fire rated glass

LA-20 Wood solid door, 20 Min fire rate door, w/frame door size; 714W. X 2133H. X 44.5 Thk.

LA-21 Wood solid door, 20 Min fire rate door, w/frame door size; 914W. X 2133H. X 44.5 Thk.

LA-22

Wood solid door, 20 Min fire rate door, w/frame door size; 915W. X 2133H. X 44.5 Thk.,STC door

LA-23

Wood solid core single door w/frame, 19mm under cut door size; 750W. X 2133H. X 44.5 Thk.

LA-24 Wood solid door w/frame door size; 664W. X 2133H. X 44.5 Thk.

LA-25 Wood solid double door, door size; 864W. X 2133H. X 34.9 Thk., 100x600 tempered glass

LA-26

Electronic card key lockset,HT-24 ONITY Co.,4ea card key, 3ea mechanical key, master key system including 4ea of battery

LA-27 Exit device, type 1, F-08, lever type

LA-28 Exit device, type 2, F-01, lever type

LA-29 Exit device, type 2, F-08, lever type

LA-30 Lockset, 1000-1, F-01, lever type

LA-31 Lockset, 1000-1, F-07, lever type

LA-32 Lockset, 1000-1, F-08, lever type

LA-33 Lockset, 4000-1, F-76

LA-34 Lockset, 4000-1, F-82

LA-35 Lockset, 4000-1, F-86

LA-36 Auxiliary dead lock, E0161

LA-37 Door coordinator, Type-21

LA-38 Floor Closer, C06041 with offset pivot

LA-39 Door closer, C02021

LA-40 Door closer, C02011

LA-41 Hinge, butt, A2111, 127 x 114 (NRP)

LA-42 Hinge, butt, A8111, 127 x 114 (NRP)

LA-43 Hinge, butt, A2133, 114 x 114 (NRP)

LA-44 Hinge, butt, A8111, 127 x 114

LA-45 Hinge, butt, A8111, 114 x 114

LA-46 Hinge, butt, A8112, 114 x 114

LA-47 Hinge, butt, A2112, 114 x 114

LA-48 Hinge, butt, A2133, 114 x 114

LA-49 Hinge, butt, A2133, 101 x 101

LA-50 Door stop and holder, Exterior type w/Conc, H9", 3"x3"

LA-51 Door stop , L02161

LA-52 Door stop , L02141

B-2

Description of Submittal

LA-53 Door stop , L02021

LA-54 Push plate, J302

LA-55 Pull plate, J405

LA-56 Automatic door bottom Roy 335

LA-57 Kick plate, J102

LA-58 Door viewer, L03221

LA-59 Auto flush bolt, Type 25

LA-60 Flush bolt, L04081

LA-61 Astragal

LA-62 Adjustable astragal

LA-63 Dustproof strike, L04011

LA-64 Threshold, aluminum, 150W, SGL

LA-65 Marble SSM threshold 150mm W

LA-66 Key box, E8351

LA-67

Aluminum blast window thermal break type, fixed & tilting window, 3000x1000, 26.75thk Low-e insulated glass, insect screen

LA-68

Aluminum blast window thermal break type, sliding window, 1200x1300, 26.75thk Low-e insulated glass, insect screen

LA-69

Aluminum blast window thermal break type, fixed & tilting window, 1200x1100, 26.75thk Low-e insulated glass, insect screen

LA-70 3/4hrs Fire rated steel fixed window, 1200 x 1100

LA-71

Aluminum thermal breaker pane glass, fixed window, 1000x1100, 10.75thkm laminated A/L sliding & fixed window

LA-72 Aluminum slidingWindow, 2000x1100, 18THK, tempered/laminated Glass

LA-73 Aluminum slidingWindow, 1200x1100, 18THK, tempered/laminated Glass

LA-74 AL louver with Insect Screen & Bird Screen

LA-75 Horizontal blinds, 1" aluminum slats

LA-76 Metal stud, 0.8 mm x 45 mm x various size W/expansion bolt

LA-77 Metal runner, 0.8 mm x 45 mm x various size W/expansion bolt

LA-78 Metal ceiling suspension system for GWB

LA-79 Acoustical ceiling suspension system, aluminum

LA-80 Gypsum board, 15mm thk x1,200 x2,400, normal

LA-81 Gypsum board, 15mm thk x1,200 x2,400, fire resistant or X

LA-82 Gypsum board, 12mm thk x1,200 x2,400, normal

LA-83 Gypsum board, 12mm thk x1,200 x2,400, water resistant or X

LA-84 Gypsum board, 12mm thk x1,200 x2,400, fire rated

LA-85 Acoustical tile, 600x600x16mm thk.

LA-86 PVC tile, KCC Neo Sense, 450 x 450 x 3Thk

B-3

Description of Submittal

LA-87 Vinyl cove base w/adhesive

LA-88 Rubber stair treads, 480 x 1200 x 3THK

LA-89

Rubber tile, size 500mm x 500mm x 3 THK, I-BADKA rubber flooring

LA-90 Rubber Base, 2THK

LA-91 Rubber stringer & risers, 178mm H X 2 THK

LA-92 Adhesive for flooring

LA-93 Paint, MPI 57, varnish

LA-94 Paint, MPI 11, acrylic emulsion, exterior

LA-95 Paint, Anti-mold and mildew, latex, interior, KCC Supro home & wellbeing, EX8816

LA-96 Paint, MPI 47, enamel, interior

LA-97 Paint, MPI 94, enamel, exterior

LA-98 Paint, MPI 79, primer for metal

LA-99 Texture coat, terracotta 25kg w/finish coat

LA-100

Noroo Paint, MPI 77, Epoxy Epoxy Paint Include Surface Preparation Base, Cleanpoxy3100, MPI77, 0.175L/M2

Mid, Cleanpoxy3100, MPI77,0.15L/M2 Top, Cleanpoxy3100, MPI77,0.15L/M2

LA-101 Toilet partition 1600 x 900

LA-102 Toilet tissue dispenser, Double Roll, Horizontal Type

LA-103 Paper towel dispenser

LA-104 Towel bar

LA-105 Soap holder, recessed type

LA-106 Mirror, 1050 x 850 with plywood back board

LA-107 Shower curtain with rod, 1,800W Curtain

LA-108 Medicine cabinet with mirror, 410MMx510MM

LA-109 Soap dispenser, liquid, wall type, SST

LA-110 Mop rack with STS shelf

LA-111 SST metal shelf for laundry room

LA-112 Laundry counter, 600 x 1000

LA-113 S.M.L.D (Shelf Metal Light Duty)

LA-114 Brass hook, STS & Wood, 3450mm LG, 8 Hooks

LA-115 Signage, interior

LA-116 Signage, exterior

LA-117 Card holder, AL, 125 x 125

LA-118 Plexi-info holder, acrylic case, 224 x 287 x 6THK w/double emulsion form tape

LA-119 Bulletin board, 1200 x 900, oak trim, tan nucork

LA-120

Bulletin board, 1800 x 1100, Fixed type w/AL trim, light fixture and sliding glass

B-4

Description of Submittal

LA-121 Kitchen Cabinet base & top, SSM Counter Top W/Plastic Laminate Finish

LA-122 Vanity cabinet, 700x650MM size, laminated counter top

LA-123 Wall hung cabinet, laminated

LA-124 Wooden shelf w/STS hanging rod, 450W x1,160 for closet

LA-125 Window trim, oak, 110W x 90W x 18Thk

LA-126 Wooden hanging rail, oak, 100W x 40Thk

LA-127 Wooden chair rail, oak, 90W x 20Thk

LA-128 Fire extinguish cabinet

LA-129 Access door

LA-130 Plywood 18T with plastic laminate

LA-131 Aluminum grating cover

OA-1

Wood solid door, 45 Min Fire Rate Door, door size; 915W. X 2133H. X 44.5 Thk., 100x600 fire glass

OA-2 Electro Magnetic door holer, C00011 (wall mount type)

OA-3 Electro Magnetic door holer, C00021 (floor mount type w/water resisant hosuing)

OA-4 Weather proof seal R0Y165 for head and jamb.

OA-5 Weather proof seal R0Y435 for bottom

OA-6 Soundproof seal R0E154 for head and jamb.

OA-7 Soundproofseal R3B435 for bottom

OA-8 Fire rated access door, 1-1/2hrs, 610 x 610

OA-9

Shaft wall(1HR,15.9T "X" type GWB&15.9T "X" GWB w/STL stud

OA-10 Cement board with nail and adhesive, 12THK

OA-11 Cement board with nail and adhesive, 6 THK

OA-12 Iron board with cabinet, 406W x 138D x 1,574H, surface mounted

OA-13 Acoustic wall panel, fabric, 25T, Armstrong sound saok

OA-14 Quarry tile with mortar bed

OA-15 Quarry tile base

LM-1 Heating boiler(1set), including rack, flue vent, control panel and associated gas piping

LM-2 Fan coil unit, Cooling cap. : 2,400 kcal/hr Heating cap.: 4,070 kcal/hr

LM-3 Fan coil unit, Cooling cap. : 4,520 kcal/hr Heating cap.: 8,890 kcal/hr

LM-4 Fan coil unit, Cooling cap. : 6,830 kcal/hr Heating cap.: 13,360 kcal/hr

LM-5 Fan coil unit, Cooling cap. : 8,140 kcal/hr Heating cap.: 14,890 kcal/hr

LM-6 Thermostat for FCU

LM-7 Balacing valve cock

LM-8 Ball valve cock

LM-9 Air conditioning unit (CU-1 & 2)

B-5

Description of Submittal

LM-10 Black steel pipe line including fittings & pipe hangers, various size

LM-11 Pipe flexible cellular insulation, various size

LM-12 Clevis hanger, various size

LM-13 Gate valve, 10Kg/cm2, various size

LM-14 Glove valve, 100 mm dia

LM-15 Ball valve, various size

LM-16 Y-type strainer, 100 mm dia

LM-17 Auto air vent eliminator,15 mm

LM-18 Diffuser (S-1) , various size

LM-19 Registers (R-1), various size

LM-20 Duct Work w/ associated accessories

LM-21 Duct insulation, Flex mineral fiber, 50mm THK

LM-22 Water hammer arrestor PDI "A"

LM-23 Water hammer arrestor PDI "B"

LM-24 Volume damper

LM-25 Pipe flexible connector, 4" dia

LM-26 Pre-air leakage test

LM-27 Post-air leakage test

LM-28 Seal pipe & duct work penetration in mech room

LM-29

Domestic hot water heater(1set), including rack, flue vent, control panel and associated gas piping

LM-30 Water closet, Tank type

LM-31 Shower unit

LM-32 Lavatory w/ faucet

LM-33 Kitchen sink w/ faucet

LM-34 Domestic hot water storage tank (DT-1), Capa.:3,407 LITS

LM-35 Copper tube water line, including fittings & pipe hangers, various size("L" type)

LM-36 Pipe flexible cellular insulation, various size

LM-37 Adhesive, armaflex 850FR

LM-38 Galvanized steel pipe with fittings & hangers, various size

LM-39 Vent thru roof

LM-40 Cast iron soil pipe with coupling, No-hub type, various size

LM-41 Bend 1/4, cast iron soil pipe, various size

LM-42 Copling, various size

LM-43 90 Y-branch, cast iron soil pipe, 100

LM-44 Y-branch double, cast iron soil pipe, various size

LM-45 P-trap, cast iron soil pipe, 50 mm dia

B-6

Description of Submittal

LM-46 V.T.R 4" DIA

LM-47 Floor cleanout, 100 mm dia

LM-48 Floor cleanout, 150 mm dia

LM-49 Floor cleanout, 200 mm dia

LM-50 Floor drain, 50 mm dia

LM-51 Fire Protection Work

LM-52 Black steel pipe line including fittings & pipe hangers, various size

LM-53 Grooved 90, elbow various size

LM-54 Grooved tee, various size

LM-55 Grooved cap, various size

LM-56 Grooved coupling, various size

LM-57 Grooved flexible coupling, various size

LM-58 Valve flange adapter, various size

LM-59 Clevis pipe hanger

LM-60 Sway Brace

LM-61 Sprinkler system shop drawing, calculatio, test & report

LM-62 Misc. Items. 3%

OM-1 Chilled/hot water circ. pump(P-1), Capa.: 755.5 LPM, 5 HP

OM-2 Hot water circ. pump(P-2), Capa.: 316 LPM, 3/4 HP

OM-3 Domestic hot water re-circ. Pump (P-3), 417.3 LPM, 1-1/2 HP

OM-4 Domestic hot water circ. Pump (P-4), 127.1 LPM, 1/4 HP

OM-5 Ceiling exhaust fan (EF-1), Cap.: 23.6LPS

OM-6 Ceiling exhaust fan (F-1), Cap.: 255 CMH

OM-7 Duct mounted, in-line fan (F-2), Cap.: 6,800 CMH

OM-8 Ceiling exhaust fan (F-3), Cap.: 1,020 CMH

OM-9 Roof exhaust fan (F-4), Cap.: 1,780 CMH

OM-10 Roof exhaust fan (F-5), Cap.: 1,330 CMH

OM-11 Wall exhaust fan (F-6), Cap.: 3,570 CMH

OM-12 Range hood, Cap.: 270 CFM, Hood size: 30"x17-1/2"

OM-13 Unit heater,Capa. 19,170 kcal/hr

OM-14 Electric water cooler,Capa. 30.3LPH

OM-15 Heating thermostat for unit heater

OM-16 Change over switch

OM-17 O.A. thermostat

OM-18 Ventilation thermostat

OM-19 Night set-back thermostat

OM-20 7-day timer

B-7

Description of Submittal

OM-21 Aquastat for pipe mounted type

OM-22 Aquastat for tank mounted type

OM-23 Suction diffuser, 100 mm

OM-24 Triple duty valve, 100 mm

OM-25 Chemical feeder

OM-26 Fire damper, variuos size

OM-27 Expansion joint, 80 mm

OM-28 Expansion joint, 65 mm

OM-29 Expansion joint, 50 mm

OM-30 Thermometer

OM-31 Pressure gauge

OM-32 Expansion tank (ET-1), Cap.: 299LITS

OM-33 Air separator, Pie size : 100 dia.

OM-34 Backflow preventer, 32 dia

OM-35 Pressure reducing valve, 32 dia

OM-36 3-way thermostatic mixing valve, 100 mm

OM-37 Hose bibb, 15 mm

OM-38 Non-freeze wall htdrant

OM-39 Gate valve, lead free(plumbing), 80mm

OM-40 Gate valve, lead free(plumbing), 100mm

OM-41 Gate valve, MSS-SP-70(HVAC), 80mm

OM-42 Gate valve, MSS-SP-70(HVAC), 100mm

OM-43 Gate valve, MSS-SP-70(HVAC), 150mm

OM-44 Trap primer, 15 mm

OM-45 Hot & Cold combination water faucet

OM-46 Service sink(P-5)

OM-47 Laundry sink(P-6)

OM-48 Washer connector box

OM-49 Downspou nozzle, 32 mm

OM-50 Fire Protection Work

OM-51 Alarm check valve, 150 mm

OM-52 Backflow preventer, 150 mm

OM-53 OS & Y valve, 150 mm

OM-54 OS & Y valve, 100 mm

OM-55 Tamper switch

OM-56 Ball valve switch, 25 mm

OM-57 Pressure switch

B-8

Description of Submittal

OM-58 Water motor alarm bell

OM-59 Check valve, 100 mm

OM-60 Check valve, 150 mm

OM-61 Fire department connection, 100mm x 65mm x 65mm

OM-62 Ball drip valve, 20 mm

OM-63 Teat header 100 x 65 x 2EA

OM-64 Hose valve w/cap & chain, 65 mm

OM-65 Test valve, 25 mm

OM-66 Water flow switch, 150 mm

OM-67 Sight glass, 25 mm

OM-68 Smooth bore corrosion resistant, 25 mm

OM-69 Pressure gauge

OM-70 Drain valve, 50mm

OM-71 Residential pendent sprinkler head, 15 mm

OM-72 Quick response pendent sprinkler head, 15 mm

OM-73 Quick response pendent sprinkler head, 20 mm

OM-74 Quick response up-right sprinkler head, 20 mm

OM-75 Quick response dry wall type sprinkler head, 15 mm

OM-76 Spare sprinkler head cabinet

OM-77 Misc. Items. 3%

OM-78 Teat header 100 x 65 x 2EA

OM-79 Hose valve w/cap & chain, 65 mm

OM-80 Test valve, 25 mm

OM-81 Water flow switch, 150 mm

OM-82 Sight glass, 25 mm

OM-83 Smooth bore corrosion resistant, 25 mm

OM-84 Residential pendent sprinkler head, 15 mm

OM-85 Quick response pendent sprinkler head, 15 mm

OM-86 Quick response pendent sprinkler head, 20 mm

OM-87 Quick response up-right sprinkler head, 20 mm

OM-88 Quick response dry wall type sprinkler head, 15 mm

OM-89 Spare sprinkler head cabinet

OM-90 Misc. Items. 3%

LE-1 Lighting fixture, exit sign stencil face LED, red lamp, LED lamp, type "NS-3"

LE-2 LED lighting fixture, 45 Watt, recessed mounted, type "NS-4a & 4b", power unit

LE-3 LED lighting fixture, 50 Watt, recessed mounted, type "NS-5a & 5b", power unit

LE-4 LED lighting fixture, 45 Watt, surface mounted, type "NS-6a & 6b", power unit

B-9

Description of Submittal

LE-5

LED lighting fixture, 18 Watt ,Surface mounted, type "NS-7", power unit (AC to DC), wet location

LE-6 LED lighting fixture, 18 Watt ,wall mounted, type "NS-8",power unit (AC to DC), mirror top

LE-7 LED lighting fixture, 22 Watt , surface mounted, exterior type, type "NS-10", power unit

LE-8 LED lighting fixture, 25 Watt, recessed mounted, type "NS-11a & 11b", power unit

LE-9 LED lighting fixture, 12 Watt, recessed mounted, type "NS-12", power unit, down light

LE-10

LED lighting fixture, 12 Watt, recessed mounted, type "NS-13", power unit, down light w/ dimming control

LE-11 Parking lot light w/pole

LE-12 SingleJack Outlet for "Telephone" system

LE-13 Coaxial Cable, RG11/U

LE-14 Coaxial Cable, RG6/U

LE-15 Pullbox w/ 8-way tap off and locking device

LE-16 Cable TV Outlets w/screw-tight cover

LE-17 Electric wires various

LE-18 Rigid steel conduit various

LE-19 Shop drawing for fire alarm control system

OE-1 Toggle switch, w/plate, 1P-20A-120VAC

OE-2 3-way toggle switch, w/plate, 1P-20A-120VAC

OE-3 Dimmer switch

OE-4 3-position sellector switch, "HAND-OFF-AUTO", "WP" housing

OE-5 Photoelectric control

OE-6 Lighting contactor

OE-7 Duplex receptacle, w/plate, 2P-20A-125VAC, gnd. Type

OE-8 Single receptacle, w/plate, 2P-20A-125VAC, gnd. Type

OE-9 Duplex receptacle, w/plate, 2P-20A-125VAC, GFCI Type

OE-10 Single receptacle, w/plate, 3P-30A-4W-125/250VAC, gnd. Type

OE-11 Single receptacle, w/plate, 4P-30A-4W-125/250VAC, gnd. Type

OE-12 Single receptacle, w/plate, 3P-50A-4W-125/250VAC, gnd. Type

OE-13 Safety switch, 3PST 600A-240V, 450A fuses, NEMA 3R. Encl

OE-14 Combination type magnetic motor starters

OE-15 Magnetic motor starters

OE-16 Manual motor starter

OE-17 Advanced Watt Hour meter

OE-18 Addressable fire alarm/mass notification control panel

OE-19 Fire Alarm Building Transmitter

OE-20 Addressable smoke detector w/sound base

OE-21 Combination fire alarm & MNS Speaker/Strobe

B-10

Description of Submittal

OE-22 Combination fire alarm & MNS Speaker "WP"

OE-23 Addressable module

OE-24 Addressable manual pull station

OE-25 Addressable carbon monoxide detector

OE-26 VHF-FM Antenna, BSA-1 type

OE-27 Lighting arrestor, LA-1 w/Encl

OE-28 Coaxial cable, w/connector, type 1 and 2

B-11

File details come from the government source that posted it. Updated .