L E G E N D
M-1
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
MECHANICAL
BELL AND SPIGOT
TRAP, ELECTRIC (INDICATE TYPE)
SOLVENT CEMENT
REDUCER, ECCENTRIC (STRAIGHT, INVERT)
REDUCER, ECCENTRIC (STRAIGHT, DOWN)
FIRE DEPARTMENT CONNECTION
M E C H A N I C A L M A T E R I A L I N D I C A T I O N S & S Y M B O L S
TEE, OUTLET DOWN
ANCHOR, MAIN
BUTTERFLY
AIR LINE
valves : (for selective actuators)
GATE, ANGLE
PLUG VALVE
GATE, GLOBE
THREE WAY
CONTROL
DPT DEWPOINT TEMPERATUREAMERICAN WIRE GAUGEAWG
CENTIGRADE
CAPACITY
BRAKE HORSEPOWER
BAROMETER(-TRIC)
BOILING POINT
PRESSURE, BAROMETRIC
COOLING LOAD
COEFFICIENT
CUBIC METER PER HOUR
COUNTER CLOCKWISE
CLASSIFICATION
CAST IRON PIPE
CHILLED WATER
CIRCUIT
CUBIC METER
COMPRESSOR
CONTINUE
CONNECTIONCONN
CONT
CU M
CPRSR
CLASS
CLG LOAD
COEF
CMH
CKT
CIP
CHW
CCW
C
CAP
BP
BARO PR
BARO
BHP
FA FACE AREA OR FRESH AIR
FHC
FLA
FHY FIRE HYDRANT
FULL LOAD AMPERES
FIRE HOSE CABINET
EFF
EWT
EXPJT
EVAP
EP
EQPT
ESP
ENT
ECON
EDR
EAT
ECC
DX
DPDT
DPV
EFFICIENCY
EXPANSION JOINT
EXTERNAL STATIC PRESSURE
EVAPORAT (-E,-ING,-ED,-OR)
ENTERING WATER TEMP
EXPLOSION PROOF
ENTERING
EQUIPMENT
DRY PIPE VALVE
DOUBLE POLE DOUBLE THROW
ENTERING AIR TEMPERATURE
EQUIVALENT DIRECT RADIATION
DIRECT EXPANSION
ECONOMIZER
ECCENTRIC
air conditioning and refrigeration
AIR COOLED
ALARM CHECK VALVE
AIR CONDITION UNIT (S)
AVERAGE
APPROXIMATE
AMPERE(AMP, AMPS)
AIR HANDLING UNIT
ALTITUDE
AMBIENT
ALUMINUM
APPARATUS DEW POINT
AIR CONDITION (-ING,-ED)
AIR COOLED CONDENSING UNIT
APPROX
AVG
AMP
AMB
AIR COND
ALT
AL
AHU
ACCU
ACLD
ACU
ACV
ADP
C/HWS
C/HWR
CHS
CHR
D
RS
RL
RD
(NAME)
M
CU MM
DIAG
DO
DIV
DIFF
DB
DIA or
DBT
CW
Cv
CWP
DECIBEL OR DRY BULB
DRY BULB TEMPERATURE
DIAGRAM
DIVISION
DIESEL OIL
DIFFERENCE
DIAMETER
DEGREE
o
CUBIC MILLIMETER
COEFFICIENT, VALVE FLOW
CLOCKWISE OR COLD WATER
CIRCULATING WATER PUMP
HOT/CHILLED WATER SUPPLY
HOT CHILLED WATER RETURN
CHILLED WATER RETURN
CHILLED WATER SUPPLY
DRAIN
REFRIGERANT SUCTION
REFRIGERANT LIQUID
CONTROL AIR MAIN
PIPE TO BE REMOVED
REFRIGERANT DISCHARGE
GLOBE
GATE
A
BALL
SQ
PLUMBING
LIQUID LINELL
PLMB
LINEAR METER
LITERS PER DAY
LITERS PER HOUR
LAUNDRY TRAY
LITERS PER SECOND
LEAVING WATER TEMPERATURE
NOT APPLICABLE
NOISE CRITERIA
NORMALLY CLOSED
METERS PER SECOND
METERS PER HOUR
MINIMUM OR MINUTE
NORMALLY OPEN
NATIONAL TAPER PIPE (THREAD)
NOT IN CONTRACTNICKG KILOGRAM
KILOGRAM PER SQ. CENTIMETER (ABSOLUTE)
KILOGRAM PER SQ. CENTIMETER
KILOGRAM PER SQ. CENTIMETER (GAUGE)KG/SQ CM G
KG/SQ CM A
KG/SQ CM
NO
N.O.
NPT
NUMBER
KILOCALORIE PER HOUR
THERMAL CONDUCTIVITY
JOULE
IRON PIPE SIZE
ISOMETRIC
DIAMETER, INSIDE
KCAL/HR
K
J
ISO
ID
IPS
HEAD
HERTZ
HORIZONTAL
HORSEPOWER
HOT WATER
HOT WATER HEATER
HOUR(S)
MERCURY
HORIZ
HZ
HW
HWH
HP
HR
HD
HG
MAX MAXIMUM
NC
N/A
N.C.
MM
MPH
MPS
MIN
MILLIMETER
M
LT
LWT
LM
LPH
LPS
LPD
METERS
SUPPLY AIRSA
SANITARY
SUBMERSIBLE
SCHEDULE
SAN
SCH
SBM
UH
UR
U
QUART
QUANTITY
PERCENT
PETROLEUM, OIL AND LUBRICANTS
POINT OF CONNECTION
PARTS PER MILLION
PRESSURE REDUCING VALVE
RADIATOR
REFRIGERANT (12, 22, ETC)
REVOLUTIONS PER MINUTE
REFRIGERATION TON
THERMAL RESISTANCE
RETURN AIR
RELATIVE HUMIDITY
RT
RH
RPM
R12, R22
R
RA
RDTR
QT
QTY
PPM
PRV
POC
POL
THERM
TONS
TYP
THK
TSTAT
TD
TEMP
SYM
STOR
SUCT
STD
STL
SSU
SSF
SST
ST
FLEXIBLE CONNECTOR
EXPANSION JOINT
EXPANSION LOOP
FLOWMETER, ORIFICE
KILOGRAM PER SQ. METER (GAUGE)
KILOGRAM PER SQ. METER (ABSOLUTE)
KILOGRAM PER SQ. METER
STRAINER, BLOW OFF
PUMP (INDICATE USE)
PRESSURE GAUGE AND COCK
PRESSURE SWITCH
KILOWATT HOUR
LATENT HEAT
LEAVING AIR TEMPERATURE
FLOWMETER, VENTURI
A B B R E V I A T I O N S
FIBERGLASS REINFORCED PLASTIC
FEMALE PIPE THREAD
GRAMS
HOSE BIBB
FACE VELOCITY
FEED WATER PUMP
GAGE OR GAUGE
GALVANIZED STEEL
FIXTURE
GA
GALVS
HB
GR
FXTR
FVEL
FWP
FLUSH VALVE
FREQUENCY
FUEL OILFO
FREQ
FRP
FPT
FV
LAT
LH
LG
LBS
L
LAV
KWH
LENGTH
POUNDS
LITERS
LAVATORY
KG/SM G
KG/SM A
KG/SM
KJ
KW
KILOJOULE
KILOWATT
P
PS
FS
STRAINER
FLOW SWITCH
OFM
VFM
EJ
BALL JOINT
(2-WAY SHOWN)
OUTSIDE AIR
NOT TO SCALE
OUTSIDE AIR INTAKE LOUVER
POLE
OXYGEN
PASCAL
PRESSURE DROP OR DIFFERENCE
PHASE (ELECTRIC)
PRESSURE GAGE
OUTSIDE SCREW & YOKE
DIAMETER, OUTSIDE
PH
PG
Pa
PD
P
OXY
OS&Y
NTS
OA
OD
OAIL
SPR
SP
SPEC
SPDT
SM
SLPD
SLPS
SLPH
SEC
SF
SG
SH
SL
sprinkler
DRY-PIPE VALVE
PRE-ACTION VALVE
SIDEWALL SPRINKLER
ALARM CHECK VALVE
PENDENT SPRINKLER
UNION, SCREWED
UNION, FLANGED
TEE, SINGLE SWEEP
UPRIGHT SPRINKLER
COLD WATER
HOT WATER SUPPLY
HOT WATER RETURN
CONDENSATE DRAIN ABOVE
SANITARY DRAIN
ACID WASTE
CHEMICAL SUPPLY PIPES
FLOOR DRAIN
CONDENSATE DRAIN BELOW
FLOOR OR GRADE
FUNNEL DRAIN, OPEN
SURFACE CLEANOUT
VENT THRU ROOF
FLOOR CLEANOUT
PIPE SLEEVE
HOSE BIBB
BACKFLOW PREVENTER
PIPE SLEEVE WITH FIRE STOPPING
FLOOR SINK (200mm x 200mm)
PITCH OR PIPE, UP(U), DOWN(D)
FLOOR OR GRADE
(NAME)E
VAC
A
HWS
MTWR
HWR
MTWS
CR
CS
FOG
FOR
FOS
FOV
FOD
MU
VPD
PC
BBD
MPC
LPC
LPS
MPS
JWS
JWR
FCO
LOW TEMPERATURE HOT WATER RETURN
LOW TEMPERATURE HOT WATER SUPPLY
MEDIUM TEMPERATURE HOT WATER RETURN
MEDIUM TEMPERATURE HOT WATER SUPPLY
VACUUM (AIR)
COMPRESSED AIR
EXISTING PIPE
FUEL OIL RETURN
FUEL OIL SUPPLY
CONDENSATE WATER RETURN
CONDENSATE WATER SUPPLY
FUEL OIL GAUGE
PLAN ELEV.
BFP
200mm x 200mm
SCO
FUEL OIL TANK VENT
PUMPED CONDENSATE
BOILER BLOW DOWN
VACUUM PUMP DISCHARGE
FUEL OIL DRAIN
MAKE UP WATER
LOW PRESSURE STEAM
JACKET WATER SUPPLY
JACKET WATER RETURN
LOW PRESSURE CONDENSATE
MEDIUM PRESSURE CONDENSATE
MEDIUM PRESSURE STEAM
ACID
(NAME)
FD
CD
G GAS
CD
VENT
PIPING
heating plumbing
MOTOR ELECTRIC
CHECK, NON-SLAM
QUICK CLOSING, FUSIBLE LINK
SQUARE HEAD BALANCING COCK
PRESSURE REDUCING
SQUARE HEAD BALANCING COCK
HOSE END DRAIN
CONTROL, PNEUMATIC-ELECTRIC
CONTROL, ELECTRIC-PNEUMATIC
ALIGNMENT GUIDE
ANCHOR, INTERMEDIATE
AIR VENT, AUTOMATIC
AIR VENT, MANUAL
W/ MEASURING TAP
MV
AVV
S AIR SEPARATOR
S
R
SAFETY
QUICK OPENING
RELIEF
PE
LOCK SHIELD
NEEDLE
valves, special duty :
EP
M
S
CHECK, SWING
SOLENOID
DIAPHRAGM
LATERAL
TEE, OUTLET UP
REDUCER, CONCENTRIC
TEE
CONNECTION, TOP
ELBOW, TURNED UP
CONNECTION, BOTTOM
ELBOW, TURNED DOWN
fitting :
FLANGED
WELDED
R
SOLDERED
CAP
BUSHING
THERMOMETER
SCREWED
THERMOSTAT, ELECTRIC
valve actuators dampers
SQUARE
WATTHOUR OR WATER HEATER
HEAT TRANSFER COEFFICIENT
UNIT HEATER
URINAL
TEMPERATURE DIFFERENCE
TONS OF REFRIGERATION
THERMOMETER
THERMOSTAT
TYPICAL
THICKNESS
TEMPERATURE
SYMBOL
STAINLESS STEEL
SAYBOLT SECONDS FUROL
SAYBOLT SECONDS UNIVERSAL
STORAGE
SUCTION
STANDARD
STEEL
STEAM
WIDTH
WEIGHT
WASHER
WATERPROOF
WATER CLOSET
WATER-COOLED
W/
WT
WTRPRF
WSHR
WITH
WD
WH
WC
WCLD
FIRE DAMPER (PROVIDE ACCESS DOOR)
ELECTRIC MOTOR OPERATED DAMPER
SMOKE DAMPER (PROVIDE ACCESS DOOR)
PRESSURE, DYNAMIC(VELOCITY)
WET BULB TEMPERATURE
STATIC PRESSURE
LPD, STANDARD CONDITIONS
LPS, STANDARD CONDITIONS
LPH, STANDARD CONDITIONS
SINGLE POLE DOUBLE THROW
SPECIFICATION
SPRINKLER
SQUARE METER
SPECIFIC GRAVITY
SECOND
SAFETY FACTOR
SENSIBLE HEAT
SENSIBLE LOAD
VOLUME
VERTICAL
VISCOSITY
WET BULB
VENTILATION
WB
WBT
W
VP
WATT
VOL
VISC
VENT
VERT
VACUUM
VALVE
VARIABLE AIR VOLUME
VELOCITY
VOLTV
VAC
VLV
VAV
VEL
SD
AD
M
VD
AD FD
S
BDD
PNEUMATIC OPERATED DAMPER
SPLITTER DAMPER
BACKDRAFT DAMPER
MANUAL VOLUME DAMPER
DUCT SECTION, POSITIVE PRESS., FIRST
EXHAUST AIR GRILLE OR REGISTER, CEILING
DUCT SECTION, NEGATIVE PRESS., FIRST
ACCESS DOOR, VERTICAL OR HORIZONTAL
CHANGE OF ELEVATION, RISE(R), DOWN(D)
COWL, (GOOSENECK) AND FLASHING
F S
FC
TRANSITION
DETECTORS, FIRE AND/OR SMOKE
TURNING VANES
FLEXIBLE CONNECTION
SOUND ATTENUATOR
FLEXIBLE DUCT
AD
R
810mm x 400mm
810mm x 400mm
810mm x 400mm
FIGURE IS ON TOP
ACOUSTICAL LINING
DIRECTION OF FLOW
FIGURE IS ON TOP
(600mm x 300mmH, 472 LPS)
TG 600/300
NECK DIAMETER)
DIFFUSER, LINEAR
CEILING DIFFUSER, ROUND TYPE (200mm
CEILING DIFFUSER, SQUARE TYPE
EXISTING WORK TO BE REMOVED
200mm NCD
SUPPLY AIR GRILLE OR REGISTER, CEILING
EXHAUST AIR GRILLE OR REGISTER, CEILING
SUPPLY AIR GRILLE OR REGISTER, SIDEWALL
RETURN AIR GRILLE OR REGISTER, CEILING
TRANSFER GRILLE ASSEMBLY
LOUVER, DOOR OR WALL
UNDERCUT DOOR (13mm, 47.2 LPS)
DOOR GRILLE (300mmx150mmH)
(500mmWx300mmH, 94.4 LPS)
500/300L
47.2
UC 13mm
300x150
DG
94.4
SR
RR
RG
SG
EG
ER
SR
SG
DUCT WORK
grilles, registers and diffusers :
RLA
LRA
RATED LOAD AMPS
LOCKED ROTOR AMPS
REMOVE EXIST WORK(R)
(E) EXISTING WORK TO REMAIN.
OR END OF DEMOLITION WORK
POINT OF CONNECTION NEW TO EXISTING
SYMBOLS
MECHANICAL MATERIAL INDICATIONS &
REPAIR BARRACKS S-827
CAMP CASEYCHONG, ST
243526
M-2
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
MECHANICAL
SCOPE OF WORK
HVAC
PLUMBING
1.
2.
4.
6.
7.
8.
9.
1.
2.
3.
WORK CLASS "K" (REPAIR / MAINTENANCE WORK)
3.
SEWER PIPING, VENT PIPING AND TEMPERATURE MIXING VALVE INCLUDING ACCESSORIES WITH NEW.
5.
ARRESTS, WASHER VALVE BOXES AND ASSOCIATED PIPING WITH NEW.
REPLACE ALL DETERIORATED EXISTING PLUMBING FIXTURES, ELECTRIC WATER COOLER, WATER HAMMER
FIRE PROTECTION
1.
REPLACE DETERIORATED EXISTING DOMESTIC COLD AND HOT WATER MAIN AND BRANCH PIPING
RISER, INSULATION, BACKFLOW PREVENTER ASSEMBLY, FLOOR DRAINS, FLOOR CLEANOUTS,
FIRE PROTECTION AND MECHANICAL GENERAL NOTES
LIKE SHALL BE DONE BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE U.S. GOVERNMENT.
24. DISPOSAL OF CONSTRUCTION DEBRIS, WASTE MATERIALS, MATERIALS RESULTING FROM DEMOLITION ACTIVITIES, AND THE
WITHIN 1M OF THE UNIT.
23. ALL CONDENSATE DRAINS FROM COOLING UNIT (AS NOTED ON THE DRAWINGS) SHALL BE PROVIDED WITH SHUT-OFF VALVE
FLUSHED IS CLEAR AS TAP WATER.
22. PIPING SYSTEM SHALL BE FLUSHED, PURGED & CLEANED PER SPECS REQUIREMENTS AND FLUSHED UNTIL ALL WATER BEING
ALL ROUND DUCT TAKE-OFFS FROM SQUARE OR RECTANGULAR MAINS.
PROVIDE AIR SPLITTER DAMPERS AT ALL BRANCH TAKE-OFFS FROM THE MAIN DUCT. PROVIDE SPIN-IN TYPE FITTINGS AT
21. PROVIDE TURNING VANES IN ALL ELBOWS THAT CHANGE AIR DIRECTION MORE THAN 30 DEGREES OR USE RADIUS ELBOWS.
BODIES EXPOSED TO AIR BELOW THE FLOOR.
AIR CONDITIONING CONDENSATE DRAINS, OR ANY OTHER COLD LIQUID WHICH MAY CREATE CONDENSATION, FROM SINK
20. INSTALL CONDENSATE DRAINS AT A MINIMUM SLOPE OF 1/4 INCH PER 1 FOOT. INSULATE ALL SEWER PIPING RECEIVING
PROVIDE REMOTELY ACTUATED DAMPERS IN AREA WITH GYPBOARD OR CONCEALED CEILINGS.
COORDINATE THE LOCATION OF ACCESS PANELS TO INSURE THAT THE EQUIPMENT CAN BE MAINTAINED ADEQUATELY.
AND FOR ANY ITEM INDISE DUCTS REQUIRING SERVICING OR INSPECTION 12"x12" ACCESS PANELS FOR TWO VALVES.
ALL AUTOMATIC CONTROL DAMPERS, FIRE DAMPERS, FIRE/SMOKE DAMPERS, DUCT SMOKE DETECTOR, BACKDRAFT DAMPERS
19. PROVIDE ACCESS PANELS TO ALL CONCEALED VALVES, DAMPERS, AND EQUIPMENT. PROVIDE ACCESS DOORS IN DUCTS AT
CALSS 500PA AND DUCTWORK SHALL MEET THE REQUIREMENTS OF SEAL CLASS C.
18. ALL SUPPLY, RETURN AND EXHAUST AIR DUCTWORK SHALL BE CONSTRUCTED ACCORDING TO SMACNA STATIC PRESSURE
TO THE PROJECT COR FOR GOVERNMENT REVIEW AND APPROVAL.
MISCELLANEOUS PROJECTS, KOREA. THE HVAC TESTING, ADJUSTING AND BALANCING (TAB) REPORT SHALL BE SUBMITTED
APPLICABLE SECTIONS OF DIVISION 22 & 23 - MECHANICAL. O & MA STANDARD TECHNICAL SPECIFICATIONS FOR
17. ALL MECHANICAL SYSTEMS SHALL BE TESTED, ADJUSTED AND BALANCED BY THE CONTRACTOR IN STRICT ACCORDANCE WITH
CONTRACTING OFFICER FOR APPROAL.
PREPARED IN THE FIELD BY THE CONTRACTOR ACCORDING TO ACTUAL FIELD CONDITIONS AND SUBMITTED TO THE
16. SOME DETAILS SHOWN ON THIS CONTRACT DRAWINGS MAY NOT MATCH EXACT FIELD CONDITIONS. SUCH DETAILS SHALL BE
GOVERNMENT.
DETAILS WILL BE UTILIZED WHILE PERFORMING THE MECHANICAL SCOPE OF WORK AT NO ADDITIONAL COST TO THE U.S.
15. FOR O & MA PROJECTS, KOREA, OCTOBER 1, 2003 DEPARTMENT OF THE ARMY FORM AS A PART OF THIS PROJECT. THE
14. CONTRACTOR SHALL SUBMIT MANUFACTURERS INSTALLATION SHOP DRAWINGS FOR APPROVAL BY GOVERNMENT.
OR REPLACED BY THIS CONTRACTOR.
EQUIPMENT, DUCT WORK, PIPING ETC. DAMAGED DUE TO THE WORK PERFORMED UNDER THIS CONTRACT SHALL BE REPAIRED
13. CONNECT TO EXISTING SYSTEM SHALL BE DONE IN SUCH A MANNER AS NOT DAMAGE THE EXISTING EQUIPMENT ANY
EQUIPMENT AND ELECTRICAL ITEMS.
THE GOVERNMENT, INCLUDING, BUT NOT NECESSARILY LIMITED TO ITEMS SUCH AS WALLS, CEILING, ROOF, PIPE, DUCT, ALLOW FOR INSTALLATION AND REPLACEMENT OF MECHANICAL AND FIRE PROTECTION SYSTEM AT NO ADDITIONAL COST TO
12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL AND REINSTALLATION OF ALL OBSTRUCTIONS AS NECESSARY TO
PROJECT AND TO MATCH CONDITION TO ADJACENT AREAS AS DIRECTED BY THE CONTRACTING OFFICER.
11. THE CONTRACTOR SHALL BE RESPONSIBLE TO CONSTRUCT OR REPAIR ALL DAMAGES TO EXISTING AREAS CAUSED BY THIS
EQUIPMENT PAD SIZE, INSTALLATION LOCATIONS, AND ADDITIONAL ITEMS.
10. THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS FOR NEW WORK SUCH AS EQUIPMENT & SERVICE CLEARANCE, COMMENCING ANY CONSTRUCTION OR RENOVATION.
9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITION AND DIMENSIONS PRIOR TO
8. ALL VALVES ON WET PIPE SYSTEM SHALL MEET NFPA 13 REQUIREMENT.
7. INSTALL SYSTEM TEST CONNECTION ON WET PIPE SYSTEM AND SHALL BE LOCATED AT THE MOST REMOTE BRANCH LINE.
6. SPRINKLERS WITH O-RINGS ARE NOT PERMITTED. PLUG TYPE TAMPER SWITCH SHALL NOT BE USED.
TO ALL RISER AND TRIM, SECTIONAL VALVES, INSPECTORS TEST VALVES AND DRAINS.
5. PROVIDE LABEL TAG INDICATING "NORMALLY OPEN" OR "NORMALLY CLOSED" ON ALL VALVES INCLUDING AND NOT LIMITED
FLEXIBLE COUPLINGS, CLEARANCES, AND SEPARATION ASSEMBLIES.
PIPING AGAINST DAMAGE WHERE SUBJECT TO EARTHQUAKES". INCLUDING, BUT NOT LIMITED TO, SWAY BRACINGS,
4. PROVIDE ALL SEISMIC PROTECTION MEASURES FOR THE FIRE PROTECTION SYSTEM IAW NFPA 13 FOR "PROTECTION OF
PIPES LESS THAN 50 MM (2 INCHES) IN NOMINAL.
OF FLUID CARRIED AND DIRECTION OF FLOW. LABELS ARE NOT REQUIRED ON SPRINKLER SYSTEM BRANCH LINES AND
CONFORMING TO ASME/ANSI A13. 1-1996, "SCHEME FOR IDENTIFICATION OF PIPING SYSTEMS", INDICATING THE TYPE
3. MARK ALL EXPOSED INTERIOR PIPING AT 8 METER (26 FT) INTERVALS, WITH PLASTIC WRAPAROUND TYPE PIPE LABELS
APPROVED FIRE STOPPING MATERIAL IAW SPECIFICATION 07 84 00.
2. THE CLEARANCES AROUND PIPE PENETRATION AT FIRE RATED WALLS AND/OR FLOOR SHALL BE PROPERLY SEALED WITH
APPROVED IN ACCORDANCE WITH NFPA 13, NFPA 20 AND THE PROJECT SPECIFICATION.
HEADS LOCATIONS WITH, LIGHTING FIXTURES, AND HVAC DEVICES. ALL EQUIPMENT SHALL BE UL LISTED AND/OR FM
CODES, MANUFACTURER'S RECOMMENDATIONS, AND EQUIPMENT LISTINGS. CONTRACTOR SHALL COORDINATE SPRINKLER
1. THE EQUIPMENT SHOWN ARE SUGGESTED LOCATIONS HOWEVER FINAL LAYOUT SHALL BE IN ACCORDANCE WITH APPLICABLE
NECESSARY DUCT CONNECTION TO FUNCTION AS ORIGINALLY INTENDED.
NEW PIPING INSTALLATION, REMOVE THE EXIST DUCTWORK AND INSTALL NEW DUCTWORK AND MAKE ALL
DUCTWORK AND PIPING ELEVATION/LOCATION. IF THE EXIST DUCT ELEVATION IS CONFLICTED WITH
9. PRIOR TO INSTALL NEW HVAC AND PLUMBING PIPING CONTRACTOR MUST COORDINATE WITH THE EXIST
NOT BE THE EXACT DUPLICATION OF THE CONTRACT DRAWING.
8. NO MECHANICAL WORK CAN BE STARTED WITHOUT AN APPROVED SHOP DRAWINGS. SHOP DRAWING SHALL
BE VERIFIED AT THE JOB SITE.
7. LOCATION AND SIZES OF EXISTING EQUIPMENT, DUCTWORK, PIPING, ETC. APPROXIMATE AND SHALL
6. ANY PIPES THAT PENETRATE FIRE RATED WALL (EXISTING/ NEW) SHALL BE SEALED PER SPEC.
CONDUITS AND ALL NECESSARY ACCESSORIES FOR H.V.A.C CONTROLS.
5. THE MECHANICAL/CONTROLS CONTRACTOR SHALL PROVIDE ALL THE WIRINGS, RELAYS, CONTROLLERS, PROVIDE REMOTELY ACTUATED DAMPERS IN AREAS WITH GYPBOARD OR CONCEALED CEILINGS.
4. PROVIDE VOLUME DAMPERS ON DUCTWORK BRANCH LINES WHETHER SHOWN ON THE DRAWINGS OR NOT.
UL LISTED.
DAMPER RATINGS SHALL BE COMPATIBLE WITH THE FIRE WALL OR FLOOR. FIRE DAMPERS SHALL BE
3. PROVIDE FIRE DAMPERS AT ALL DUCT PENETRATIONS THROUGH FIRE RATED WALLS AND FLOORS. FIRE
TO ARCHITECTURAL DRAWINGS FOR CEILING TYPES.
2. PROVIDE DIFFUSERS AND GRILLE FRAMES COMPATIBLE WITH ARCHITECTURAL CEILING TYPES. REFER
FLEXIBLE DUCTWORK FOR VIBRATION ISOLATION.
1. ALL EQUIPMENT CONNECTIONS TO DUCTWORK SHALL HAVE A MIN. OF 100MM OF REINFORCED CANVAS
NOTES
REPLACE THE DETERIORATED EXISTING SUPPLY AIR DUCTS, DUCT INSULATION, DIFFUSERS, REGISTERS, LOUVERS
DAMPERS, GRILLES AND ASSOCIATED ACCESSORIES WITH NEW.
REPLACE THE DETERIORATED EXISTING CHILLED/HOT WATER CIRCULATION PUMP, AIR SEPERATOR, EXPANSION
TANK, CHEMICAL FEEDER, CONTROL SYSTEM AND ASSOCIATED PIPING WITH NEW.
REPLACE THE DETERIORATED EXISTING ALL CHILLED/HOT WATER MAIN AND BRANCH-PIPING RISERS, INSULATION, DUCTWORK AND INCLUDING ACCESSORIES WITH NEW.
REPLACE ALL DETERIORATED EXISTING WALL MOUNTED EXHAUST FANS, ROOF MOUNTED EXHAUST FANS, IN-LINE EXHAUST FAN, CEILING EXHAUST FANS, CONTROL AND ALL ASSOCIATED DUCTWORK WITH NEW.
& DUCTWORK WITH NEW.
REPLACE THE DETERIORATED EXISTING RANGE HOOD, UNIT HEATERS, CONTROL AND ALL ASSOCIATED PIPING
REPLACE THE DETERIORATED EXISTING EXHAUST AIR DUCTWORK, DRYER VENT, SQUARE DIFFUSERS, REGISTER, GRILLES, OUTSIDE AIR INTAKE LOUVER, OUTSIDE AIR OPENING W/MOTORIZED DAMPER WITH NEW.
PERFORM DALT(DUCT AIR LEAKAGE TEST) AND T.A.B(TESTING, ADJUSTING. AND BALANCING) AFTER
CONSTRUCTION TO VERIFY IF THE HVAC SYSTEM WORKS PROPERLY.
PROVIDE FINAL-AIR LEAKAGE TEST REPORT.
PRE-AIR LEAKING TEST IS REQUIRED PRIOR TO REPAIR INFILTRATION AND SEALING AT MECHANICAL ROOM.
REPAIR INFILTRATION AND SEAL AIR LEAKING PORTIONS INCLUDING CLEARANCE BETWEEN WALL CEILING
AND PENETRATORS(DUCT, WATER PIPING, CONDUCT PIPE, FLUE VENT PIPE AND ETC) AT MECHANICAL ROOM.
REPLACE THE DETERIORATED EXISTING, HOT WATER STORAGE TANK, DOMESTIC HOT WATER CIRC. PUMP, DOMESTIC HOT WATER RECIRC. PUMP, CONTROL SYSTEM AND ASSOCIATED PIPING WITH NEW.
REPLACE THE DETERIORATED EXISTING AUTOMATIC FIRE PROTECTION SPRINKLER SYSTEM, AND ALL
ASSOCIATED ACCESSORIES, FOR FIRE PROTECTION SYSTEM WITH NEW.
GENERAL NOTES, NOTES & SCOPE OF WORK
FIRE PROTECTION AND MECHANICAL
REPLACE THE DETERIORATED EXISTING FAN COIL UNITS, AIR CONDITIONING UNITS, ROOM THERMOSTAT, CONTROL, ACCESSORIES AND ASSOCIATED PIPING WITH NEW.
REPAIR BARRACKS S-827
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
MECHANICAL
M-3
M E C H A N I C A L E Q U I P M E N T S C H E D U L E-1
EQUIPMENT SCHEDULE - 1
316.0
BASE MOUNTED
PIPE MOUNTED 3/45.8
P
P
CHILLED/HOT WATER CIRC. PUMP 16.8 200/ 3/ 60755.5
REMARKS
VOLT/PH/HZHP
MOTOR
HEAD (M)
LPM
CAPACITY
T Y P ESERVICEITEM NO
HOT WATER CIRC. PUMP FOR
WINTER SEASON HEATING ZONE
200/ 3/ 60
RPM
1,750
1,750
P
3 RECIRC. PUMP
DOMESTIC HOT WATER
P
PIPE MOUNTED 417.3 200/ 3/ 607.9 1,750
DOMESTIC HOT WATER
CIRC. PUMP PIPE MOUNTED 115/ 1/ 603.9 1/4 1,750
END SUCTION TYPE
W/VIBRATION ISOLATOR
W/VIBRATION ISOLATOR
ALL BRONZE CONSTRUCTION
Q'TY
ALL BRONZE CONSTRUCTION
PUMPS
1-1/2
127.1
3002 21
21260 115/1/60
WB
REMARKS
SUPPLY FAN
EWTEAT
HEATING
HEAT CAPEWT
CHILLED/HOT WATER COIL
VOLT/ PH/ HZ
EAT
COOLING
SENSIBLE(CMH) TOTAL
TYPE
WBDB
Q'TYITEM NO
FCU
FCU
FAN COIL UNIT
LPM
115/1/60 6
AIR CAPACITY
6,830
8,140 7,326
6,147
14,890
13,360
W
NOTES: 1
CENTURT ACE MODEL #CAF-300 OR APPROVED EQUAL.
2209 21
VERTICAL CABINET
115/1/60
FLOOR MTD. TYPE
FCU
FCU
115/1/60 4
7510 2,400
4,520 4,068
2,160
8,890
4,070 9
HORIZONTAL CEIILING MOUNTED
CONCEALED TYPE
HORIZONTAL CEIILING MOUNTED
CONCEALED TYPE
HORIZONTAL CEIILING MOUNTED
CONCEALED TYPE
1,260
1,650
1,830
(KCAL/HR) (KCAL/HR) WB
LAT
WBDB
19.5
19.5
19.5
19.5
(KCAL/HR)
EACH UNIT SHALL INCLUDE MANUFACTURE VALVE PACKAGE AS INDICATED ON DETAIL DWG.
COIL CAPACITY SHALL BE BASED ON THE COOLING REQUIREMENTS.
CENTURT ACE MODEL #FC-H61 OR APPROVED EQUAL.
FAN MOTOR UL LISTED:FILE NO. E235242.
CENTURT ACE MODEL #FC-H81 OR APPROVED EQUAL.
CENTURT ACE MODEL #FC-H101 OR APPROVED EQUAL.
9 WARRENTY PERIOD : 3YEARS
W/VIBRATION ISOLATOR.
CMH
GAS FIRED HOT WATER BOILER
ITEM NO
BLDG. HEATING SYSTEM1
SERVICEQ'TY TYPE
VOLT/PH/HZ
120/1/60
ELEC. POWER
8.57
GAS
INPUT
kW
OUTPUT
GROSS
FLA �
SUPPLY
80.0
WATER TEMP
kPa
WORKING
PRESS REMARKS
92.0
EFFICIENCY
CASCADE
SYSTEM
NAVIEN CONDENSING BOILER MODEL NCB-210 X 2EA,
206.85 CSA CERTIFY PRODUCT, ASME CERTIFY PRODUCT OR
APPROVED EQUAL.
TYPE
GAS FIRED DOMESTIC HOT WATER HEATER
ITEM NO SERVICE
Q'TY
4,324.2
HEAT
RECOVERY
168 2
ELEC. POWER
13.71 120/1/60 60.0 16.7
SUPPLY
TEMP RISE
TEMP
REMARKS
EFFICIENCY
97.0
CASCADE
SYSTEM
BLDG. DOMESTIC
HOT WATER SYSTEM
CMHkW
OUTPUT
GROSS
CMH
GAS
INPUT
VOLT/PH/HZFLA � �
NAVIEN CONDENSING WATER HEATER MODEL
NPE-241S X 3EA, CSA CERTIFY PRODUCT OR
APPROVED EQUAL.
B
DWH
F
1 (0.25")
115 / 1 / 601.0AMPS
REMARKS
VOLT/PH/HZHP
FAN MOTOR
RPM
("WG)
ESP
(CMH)
AIR CAP.
ITEM NO SERVICE T Y P E
1,550
F 6,800 1,045
(0.9")
EXHAUST AIR FAN
FOR 1ST FL. TOILET
DUCT MOUNTED, BELT DRIVEN
IN-LINE CENTRIFUGAL FAN
F
1,020
CEILING EXHAUST AIR FAN
FOR MUD ROOM
DIRECT DRIVEN
FORWARD CURVED CENTRIFUGAL FAN
CEILING MOUNTED,
1,080 (0.25")
4.4AMPS
WHEEL
DIAMETER
F 3,570
WALL EXHAUST AIR FAN
FOR MECH. RM
BELT DRIVEN
CENTRIFUGAL FAN
WALL MOUNTED,
F
F
1,780FOR LOUNGE, GAME RM,
FOR BATH ROOMS
ROOF EXHAUST AIR FAN
ROOF EXHAUST AIR FAN
& JAN.
BELT DRIVEN
CENTRIFUGAL FAN
ROOF MOUNTED,
(0.5") 1,400 400 1/2
(0.375")
(0.375")
1,135
955 350
350 1/4
1/4
EXHAUST AIR FAN
FOR LAUNDRY AREA
BELT DRIVENROOF MOUNTED,
CENTRIFUGAL FAN
FORWARD CURVED CENTRIFUGAL FAN
CEILING MOUNTED, DIRECT DRIVEN
W/VIBRATION ISOLATOR200 / 3 / 60
115 / 1 / 60
115 / 1 / 60
115 / 1 / 60
115 / 1 / 60 mmAq
12.7
9.53
9.53
6.35
22.9
6.35
1,330
(mm)
BACKDRAFT DAMPER
CURB MOUNTED.
BACKDRAFT DAMPER
CURB MOUNTED.
BACKDRAFT DAMPER
CEILING FAN, INTEGRAL
Q'TY
F A N S
EF
115 / 1 / 6045WATTS
EXHAUST AIR FAN
CEILING MOUNTED, DIRECT DRIVEN
92 FOR BATHROOM CENTRIFUGAL FAN 23.6LPS 62.3Pa 675
1. W/BACKDRAFT DAMPER
2. W/DISCONNECT SWITCH
REPAIR BARRACKS S-827
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
MECHANICAL
M-4
M E C H A N I C A L E Q U I P M E N T S C H E D U L E-2
EQUIPMENT SCHEDULE - 2
ET
8.75600 x 1,530299 LITSDIAPHRAGM TYPE
SYSTEM
REMARKSPRESSURE
WORKING
(mmDIA x mmHEIGHT)
TANK SIZE
(LITS)
TANK CAP.
T Y P ESERVICEITEM NO
CHILLED / HOT WATER
CHARGE PRESSURE=0.84KG/SM
(KG/SM)
Q'TY
EXPANSION TANK
ENTIRE BUILDING
1,524DIA x 1,800H
REMARKS
(mmDIA x mmLONG )
TANK SIZE
(LITS)
CAPACITY
TANK
ITEM NO SERVICE T Y P E
STL, ROUND
VERTICAL TYPE
DT
Q'TY
3,407
DOMESTIC HOT WATER STORAGE TANK
AS
ITEM NO SERVICE
HOT WATER
SYSTEM
TYPE REMARKS
EWC
MOTOR : 1/5 HP, 115 V, 1 PH, 60 HZ.
CAPACITY : 30.3 LPH, 26.6 DEG. C TO 10 DEG. C.
STANDARD 1010.
& COMPRESSOR SHALL CONFORM TO ARI
AIR COOLED WITH AIR COOLED CONDENSER
FLOOR MOUNTED TYPE, MECHANICALLY
D E S C R I P T I O NITEM NO
ITEM NO
RH
CAPACITYSERVICE T Y P E FAN MOTOR
(CMH)
FAN
270CMH
VENTED TYPE
STAINLESS STL HOOD 2.5 AMPS
HOOD SIZE
KITCHEN
(mm)
(115V/1PH/60HZ)
Q'TY
Q'TY
Q'TY
PIPE
MOUNTED
PIPE SIZE
INLET OUTLET
EXPANSION
PIPE SIZE
100DIA 32DIA100DIA
AIR SEPARATOR
30"x17-1/2"
3 BUILT-IN CONTROL SWITCH21 WASHABLE FILTER LIGHTING(75W)
RANGE HOOD
ELECTRIC WATER COOLER
71.0
(DEG. C)
EWT
Q'TY
UH
ITEM NO
MECH. RM(134)
SERVICE
19,170
(KCAL/HR)
CAPACITY
HEATING
DISCHARGE TYPE
HORIZONTAL
T Y P E
57.6
LPM
VOLT/PH/HZ
115/ 1/ 601,050
RPM
10.0 2,290
EAT
(DEG. C) CFM
1/10
FAN CAPACITY
HP
REMARKS
UNIT HEATER
SUPPORT SADDLE
PROVIDE W/CEMENT LINING AND
REPAIR BARRACKS S-827
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
MECHANICAL
M-5
CORRIDOR CORRIDOR
STORAGE STORAGE
MECH. ROOM
SLEEPING
LIVING/
111 112 113 114 115 116
LIVING/
SLEEPING
119 118 117
110109108107106105
LIVING/
SLEEPING
SLEEPING
LIVING/
SLEEPING
LIVING/
103 102 101
STAIR-2
STAIR-3
VEST
VEST
COMM.
EWC
124 122
STAIR-1
LAUNDRY
MUD
ROOM
CLOSET
TOILET
JAN.
LOBBY
ROOM
EXERCISE
TEL.
VEST.ISSUE
ROOM
C /H
W R
STAIR-2
C /H
W S
FCU
C /H
W S
D
FCU
1 1
FCU
C /H
W S
C /H
W R
C /H
W S
D
202532
C /H
W S
C /H
W R
C/HWR
D
C /H
W S
FCU
FCU
VEST
FAN COIL UNIT
C /H
W S
C /H
W R
C /H
W
SD
FCU
C /H
W S
C /H
W R
D
FCU
EXPANTION JOINT
BELLOWS TYPE
C /H
W S
C/HWS
50 65
(TYPICAL)
C /H
W R
C /H
W S
FCU
D
FCU
C /H
W S
FCU
C /H
W R
C /H
W S
FCU
D
FCU
FCU
C /H
W S
C /H
W S
C /H
W R
D
FCU
C /H
W S
C /H
W S
C /H
W R
FCU
D
FCU FCU
C /H
W S
C /H
W S
C /H
W R
D
FCU
C/HWS
FCU
FCU
C /H
W S
C /H
W R
C /H
W S
D
FCU
C /H
W S
C /H
W R
FCU
C /H
W S
D
C /H
W S
D
C /H
W S
FCU
C /H
W R
D
C /H
W R
C /H
W S
D
C /H
W S
VENT
FAN COIL UNIT
(TYPICAL)
SEE DETAIL
(TYPICAL)
PIPE ALIGNMENT GUIDES
(TYPICAL)
SEE PIPE ANCHOR
DETAIL(TYPICAL)
C /H
W S
SEE PLUMBING
PIPING PLAN
C/HWS
FCU
C /H
W R
D
SEE DETAIL "A"
25 DRAIN
BETWEEN WALL
DRAIN LINE DOWN
AND DRIVE-IT
INSULATION
INSULATION
AND DRIVE-IT
BETWEEN WALL
DRAIN LINE DOWN
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
CONDENSATE DRAIN RISERS
C/
HW
R
D
(TYPICAL)
CONN. TO FCU
C/
HW
S
CHILLED/HOT WATER
SUPPLY/RETURN &
DETAIL "A"
SCALE: 1 / 20
DOW
NSP
OUT
NOZZ
LE
20VAL
VE
(T
YP
SEE MECH. RM. PARTIAL PLAN
SCALE : 1 / 100
HVAC PIPING PLAN (1ST FLOOR)
M5
M9
DRAIN PIPING W/NEW.(TYP)
T T T T T T T T T T T T
TTTT
T
TTTT
TO BE REPLACED (TYP)
EXISTING ROOM THERMOSTAT
M33
M30
M31
REPLACE ALL EXISTING C/HWS
PIPING W/NEW.(TYP)
REPLACE ALL EXISTING C/HWS, C/HWR,
M22
HVAC PIPING PLAN(1ST FLOOR)
AND NOTES
C /H
W R
UP
FECFEC
UP
D.S
UP
BIB
HOSE
F.D
COUNTER
W W W W W W W
D
DD
D
F.D
DDD
D D D
COUNTER
COUNTER
WWWWWWW
COUNTER
V V
B/B
B/B
C
H W
S
DC
H W
R
D
C
H W
R
C
H W
S D
T
1. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE AND
DIRECTION OF HOT/CHILLED WATER AND DRAIN PIPING IN FIELD (TYP.).
2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR HVAC PIPING
PRIOR TO HVAC PIPING INSTALLATION.
3. PROVIDE CEILING/WALL ACCESS PANEL FOR VALVES.
INSPECTION WHEN THE INSTALLATION OF THE PIPE INSULATION IS COMPLETED.
4. THE CONTRACTOR SHALL INVITE THE MECHANICAL ENGINEER FOR QUALITY
IN ACCORDANCE WITH ASTM E84.
A MAXIMUM SMOKE DEVELOPED INDEX OF 50 WHEN TESTED
SHALL HAVE A MAXIMUM FLAME SPREAD INDEX OF 25 AND
3. LAGGING ADHESIVES SHALL BE NONFLAMMABLE AND FIRERESISTANT AND
2. INSULATION MATERIALS RECOGNIZED UNDER UL94 AND LISTED IN FM APP GUIDE.
07 00, AND SHALL COMPLY WITH ASTM C534/C534M, GRADE 1, TYPE I OR II.
1. INSULATION MATERIALS SHALL CONFORM TO TABLE1 OF OMA SPEC 23
NOTE ON INSTALLATION OF PIPE INSULATION
NOTES:
REPAIR BARRACKS S-827
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
MECHANICAL
M-6
CORRIDOR
2ND FL : KITCHEN
3RD FL : LOUNGE 325
224 223
STAIR-2
STAIR-3
VEST.
VEST.
327 227
JAN.
235 335
C /H
W R
C /H
W
SD
C /H
W R
FCU
C /H
W S
C /H
W S
C /H
W
SD
C /H
W R
D
FCU
1 C /H
W R
D
C /H
W S
C /H
W S
C /H
W R
D
FCU
1 C /H
W R
D
FCU
FAN COIL UNIT
FCU
C /H
W R
C /H
W
SD
D C /H
W R
C /H
W S
FCU
C /H
W S
FCU
C /H
W
RD
C /H
S
1 1
FCU D
C /H
W R
C /H
W S
FCU FCU
1 C /H
W
RD
C /H
W S
D C /H
W R D
C /H
W S
C /H
R
FCU
C /H
W
RD
C /H
W S
FAN COIL UNIT
COUNTER & CABINET @2ND FL. ONLY
FAN COIL UNIT
FCU
C /H
W
RD
C /H
W S
C /H
W S
C /H
W S
C /H
W R
D
FCU
D
C /H
W R
C /H
W S
C /H
W R
C /H
W
SD
FCU
D
C /H
W R
C /H
W S
C /H
W
SD
C /H
W R
FCU
D
C /H
W
R FCU
FAN COIL UNIT
C /H
W R
D
C /H
W S
FCU
C /H
W S
C /H
W R
D
D
C /H
W S
C /H
W R
C /H
W R
FCU
FCU
C /H
W
RD
C /H
W S
FCU
1 1
FCU
FCU
C /H
W S
D C /H
W R
C /H
W S
D C /H
W R D
C /H
W S
C /H
W R
D
C /H
W S
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
SLEEPING
LIVING/ LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING SLEEPING
LIVING/
SLEEPING
LIVING/
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING SLEEPING
LIVING/ LIVING/
SLEEPING
LIVING/
SLEEPING
SCALE : 1 / 100
HVAC PIPING PLAN (2ND - 3RD FLOOR)
M6
DRAIN PIPING W/NEW.(TYP)
T T T T T T T T T T T T
T
T
TO BE REPLACED (TYP)
EXISTING ROOM THERMOSTAT
TTTTTTTTTTT
T
T
FCU
REPLACE ALL EXISTING C/HWS, C/HWR,
AND NOTES
HVAC PIPING PLAN(2ND-3RD FLOOR)
C /H
W R
C /H
W R
DN UP
D.S
STORAGE
STAIR-1
UP
DN
STORAGE
FEC
FECFEC
UP DN
REFREF
1. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE AND
DIRECTION OF HOT/CHILLED WATER AND DRAIN PIPING IN FIELD (TYP.).
2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR HVAC PIPING
IN ACCORDANCE WITH ASTM E84.
A MAXIMUM SMOKE DEVELOPED INDEX OF 50 WHEN TESTED
SHALL HAVE A MAXIMUM FLAME SPREAD INDEX OF 25 AND
NOTE ON INSTALLATION OF PIPE INSULATION
NOTES:
REPAIR BARRACKS S-827
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
MECHANICAL
M-7
VEST.
STAIR-2
403405 404 402 401
410408 409 411 412
4TH FL : GAME ROOM
REF
STORAGE
CORRIDOR
JAN.
COMM.
STAIR-1
STORAGE
422423 421 420 419
415414 416 417 418
VEST.
STAIR-3
FCU
2032 25
C /H
W R
C /H
W
SD
FAN COIL UNIT
FCU
C /H
W R
C /H
W R
C /H
W
SD
FCU
C /H
W R
C /H
W
RD
C /H
S
C /H
W R
FCU
FCU
C/HWR
C/HWR
FCU
D
C /H
W S
C /H
W R
C /H
W R
FCU
D
C /H
W S
BELLOWS TYPE
EXPANSION JOINT
FCU
C /H
W R
C /H
W R
D C /H
W S
(TYPICAL)
FCU
FCU
C /H
W R
C /H
W R
D C /H
W S
1 1
FCU
FCU
C /H
W R
FCU
D
C/HWR
C/HWS
FCU
D
C /H
W R
C /H
W S
C /H
W R
C /H
W R
C /H
W S
D C /H
W R
FCU
C /H
W R
FCU
FCU
D
C /H
W S
C /H
W R
FCU
C /H
W R
FCU
D
C /H
W S
C/HWR
C/HWR
FCU
C /H
W R
C /H
W
SD
C /H
W R
FCU
C /H
W R
C /H
W R
C /H
W
SD
FCU
FCU
FCU
C /H
W R
C /H
W S
C /H
W R
D
C /H
W R
C /H
W R
C /H
W
SD
FCU FCU
FCU
(TYPICAL)
FAN COIL UNIT
SEE
DETAIL "A"
50 65 80
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
BALANCING VALVE
GATE VALVE
HWR PIPING
HWR PIPING
DETAIL "A"
SCALE : 1 / 100
HVAC PIPING PLAN (4TH FLOOR)
M7
DRAIN PIPING W/NEW.(TYP)
T
EXISTING ROOM THERMOSTAT
TO BE REPLACED (TYP)
T T T T T T T T T T T
T
TTTTTTTTTTTT
T
T
20 AUTO AIR VENT
(TYPICAL)
REPLACE ALL EXISTING C/HWS, C/HWR,
REPLACE ALL EXISTING C/HWS, C/HWR
PIPING(TYP) W/NEW.
SEE PIPE ANCHOR
DETAIL(TYPICAL)
M30
15 AUTO AIR VENT
PIPE ALIGNMENT GUIDES
(TYPICAL)
M36
HVAC PIPING PLAN(4TH FLOOR)
AND NOTES
C /H
W R
DN UP
FEC
REF
DN
FEC
UP
FEC
UP DN
FEC
1. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE AND
DIRECTION OF HOT/CHILLED WATER AND DRAIN PIPING IN FIELD (TYP.).
2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR HVAC PIPING
IN ACCORDANCE WITH ASTM E84.
A MAXIMUM SMOKE DEVELOPED INDEX OF 50 WHEN TESTED
SHALL HAVE A MAXIMUM FLAME SPREAD INDEX OF 25 AND
NOTE ON INSTALLATION OF PIPE INSULATION
NOTES:
REPAIR BARRACKS S-827
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
MECHANICAL
M-8
105 106
207 208
307 308
407 408
108107
210209
310309
410409
101102
203204
303304
403404
110109
212211
312311
412411
201202
301302
401402
223224
323324
423424
114113
216215
316315
416415
119120
221222
321322
421422
116115
218217
318317
418417
117118
219220
319320
419420
130 123
134 134
C /H
W R
C /H
W S
C /H
W S
C /H
W R
C /H
W S
C /H
W R
C /H
W S
C /H
W R
C /H
W S
C /H
W R
C /H
W S
C /H
W R
C /H
W S
C /H
W R
C /H
W S
C /H
W R
C /H
W S
C /H
W R
C /H
W S
C /H
W R
C /H
W S
C /H
W R
C /H
W S
C /H
W R
C /H
W R
C /H
W R
C /H
W S
40 50
20 25
25 25
25 20
20 32
32 32 32 32 32
100 32 20
3220 3220
20 32 20 32 20 32
2525 2525 25 25 25 25 25 25
25 50
2020 2020 2020 20 20 20 20 20 20
50 65 65 80
80 80 80 80 65 65 50 50 25
20 20 20 20 20 20 20 20 20 20
100 20 32 25 25 2525 25 25 25 25 25 25
25 25
20 25
100 25 32 3220 2520 3220 20 32 20 32 20 32
32 32 32 32 32 32
1ST. FLOOR
2ND. FLOOR
3RD. FLOOR
4TH. FLOOR
FCU FCU
FAN COIL UNIT.
(TYPICAL.)
FCU
FCU FCU FCU FCU FCU FCU FCU FCU FCUFCU FCU FCU
FCU FCU FCU
FCU FCU
FCU
FAN COIL UNIT.
(TYPICAL.)
FCU
FCUFCUFCU
FCUFCU
FCU
FCU FCUFCU FCU
FCU
FCU
FCU
FCUFCU
FCU FCUFCU FCU
FCU FCUFCU FCUFCU
FCU
FCU FCUFCUFCU FCU
FCU FCU
FCU
FCU FCU
FCU
FCU
FCU
FCU FCU FCU
FCU FCU
FCU FCU
FCU FCUFCU
1 1
FCU
FCU
FCU
1 1
FCU
FCU FCU
1 1
FCU FCU
1 1
FCU FCU
FCU
1 1
FCU FCU
1 1
FCU
FCU
FCU
FCUFCU
1 1
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
(TYPICAL.)
FAN COIL UNIT.
FAN COIL UNIT.
(TYPICAL.)
(TYP. OF 6)(TYP. OF 6)
C /H
W S
C /H
W R
EXPANTION JOINT,
BELLOWS TYPE
(TYP.)
C /H
W R
C /H
W S
20 2025 20
(TYPICAL.)
25323232 3232 3232323232 32
DRAIN VALVE
(TYPICAL)
FCU
FCU
FCU
FCU
CALIBRATE
BALANCING VALVE (TYP.)
25 DRAIN TO MECH. ROOM
SEE M13/M17
NOT TO SCALE
HVAC PIPING SCHEMATIC DIAGRAM
M8
AND NOTES
HVAC PIPING SCHEMATIC DIAGRAM
BALLANCE VALVE
(TYP OF 106)
C
H W
R
C
H W
S
1 1 1 1 1 1 1 1 1 1 1 1 1 1
111111111111111
1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1
REPAIR BARRACKS S-827
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
MECHANICAL
M-9
FOR CONT.
FOR CONT.
P VALVE
32100
C /H
W S
D
4020 25
25 DRAIN
ELEC. SPACE
P
P
P
C/HWS
C/HWR
AS
ET
MECH. ROOM
HWS
HWR
C H
R
C H
S
100 100
DT
BELOW GRADE
65 80100 80
.3
C
C
.3
C
SCALE : 1 / 50
MECH. ROOM PARTIAL PLAN
M9
M5
50F.D.
(GAS FILTER, GAS REGULATOR, GAS METER
CHAINLINK FENCE, GAS PIPING, AUTOMATIC
GAS LEAK DETECTION SYSTEM)
SHUT UP VALVE, GAS ALARM GONG AND
SEE HVAC PIPING PLAN(1ST FLOOR)
M17
SEE PLUMBING PIPING PLAN(1ST FLOOR)
REPLACE EXISTING DETERIORATED ALL HVAC
AND PLUMBING PIPING W/NEW.
ALL EXISTING GAS SYSTEM TO BE REMAINED
MECH. ROOM PARTIAL PLAN AND NOTES
H
TO
C
TO
W/REMOTE BULB W/NEW.
W
S
POC
MAIN COLD WATER LINE
C /H
W R
CHEMICAL FEEDER
BACK-FLOW
PREVENTER ASSEMBLY
DOMESTIC H.W. MIXING VALVE
TEMP. & PRESSURE
RELIEF VALVE
OUTDOOR AIR THERMOSTAT
M
E
REDUCING VALVE
PRESSURE
UH
PG FJ
TM
FS
PG FJ
TM
FS
NEW DRAIN PIT
CONC. PAD
C H
S
C H
R
REMOVE & REINSTALL EXISTING TWO CHILLERS WITH WIRING.
REMOVE EXISTING
CONC. DIKE
REMOVE EXISTING
FLANGES
REMOVE EXISTING
LEAK DETECTOR
M
REMAIN EXISTING AIR HANDLING UNIT
AND ASSOCIATED DUCTS.
AND ASSOCIATED DUCTS.
REMAIN EXISTING HEATING & VENTILATION UNIT
REMAIN EXISTING HEATING & VENTILATION UNIT
AND ASSOCIATED DUCTS.
POC
POC
POCPOC
REPLACE EXISTING RACK, GAS PIPING, FLU VENT AND WIRING WIRH NEW.
ADD HEATING BOILER(1SET) AND ASSOCIATED ACCESSORIES.
REPLACE EXISTING RACK, GAS PIPING, FLU VENT AND WIRING WIRH NEW.
REMOVE & REINSTALL EXISTING HEATING BOILERS(6SETS)
REMOVE & REINSTALL EXISTING DOMESTIC HOT WATER HEATERS(4SETS)
ADD DOMESTIC HOT WATER HEATER(1SET) AND ASSOCIATED ACCESSORIES.
1. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE AND
DIRECTION OF HOT/CHILLED WATER AND DRAIN PIPING IN FIELD (TYP.).
2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR HVAC PIPING
IN ACCORDANCE WITH ASTM E84.
A MAXIMUM SMOKE DEVELOPED INDEX OF 50 WHEN TESTED
SHALL HAVE A MAXIMUM FLAME SPREAD INDEX OF 25 AND
NOTE ON INSTALLATION OF PIPE INSULATION
NOTES:
NOTE ON EXISTING GAS BOILER & HOT WATER HEATER
CONTACT INFORMATION OF KYONGDONG IS MR, SHIN, DONGIK/TEL NO. ; 010-4175-1111
THE NECESSARY ACTIONS TO PROTECT THE SYSTEM BASED ON THEIR ADVICE.
BEFORE STARTING CONSTRUCTION TO INFORM THE CONSTRUCTION SCHEDULE AND TAKE ALL
THE CONTRACTOR MUST CONTACT THE BOILER & HEATER MANUFACTURER "KYONGDONG NAVIEN"
REPAIR BARRACKS S-827
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
MECHANICAL
M-10
EXHAUST
SUPPLY
RETURN
SUPPLY
SUPPLY
EXHAUST
APPEARANCE SHALL MATCH S-1
AIR DEVICE SCHEDULE
FOR SURFACE MOUNTED UNITS ON PLASTER
SHALL BE THE MANUFACTURERS STANDARD
DIMENSIONS OF PERFORATED PANELS
SEE ARCH. DWG. FOR CEILING TYPE.
MOUNTING IN SUSPENDED TILE CEILING
NOMINAL 600x600 PERFORATED FOR
EQUALIZING DEFLECTOR
FUNCTION
WHITE ENAMEL 1
CEILINGS.
S-2
E-2
S-3
R-1
E-1
S-1
UNIT NO.
REMOVABLE PERFORATED PANEL
STEEL
PATTERN CONTROLLER
VOLUME DAMPER
ALUMINUM
4-WAY THROW UNLESS OTHERWISE
OPPOSED BLADE DAMPER
STEEL
STEEL
STEEL
MATERIAL
STEEL
DOUBLE DEFLECTION REGISTER WITH
FIXED HORIZONTAL BARS, 45 DEFLECTION.
HORIZONTAL FACE BARS.
INDICATED
LINEAR SLOT DIFFUSER
PERFORATED REGISTER
PERFORATED DIFFUSER
REGISTER
REGISTER
GRILLE
TYPE TYPE ACCESSORIES
9 10
FINISH
1 52
REMARKS
3 116
20(MM) SLOT12
SCALE : 1 / 100
HVAC DUCT PLAN (1ST FLOOR)
M10
HVAC DUCT PLAN(1ST FLOOR) AND NOTES
SLEEPING
LIVING/
SLEEPING
SLEEPING
LIVING/
SLEEPING
VEST
STAIR-2
SLEEPING
LIVING/
ROOM
ISSUE
VEST.
CLOSET
ROOM
MUD
SLEEPING
LIVING/
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
103 102
JAN.
ROOM
EXERCISE
124134CORRIDOR
SLEEPING
LIVING/
SLEEPING
LIVING/
LIVING/
SLEEPING
LIVING/
109 110
B/B
STORAGE
139 122
LOBBY
TOILET
COMM.
STORAGE
STAIR-1
LAUNDRY
MECH. ROOM
LIVING/
SLEEPING
LIVING/
SLEEPING
CORRIDOR
SLEEPING
LIVING/
120 119
LIVING/
SLEEPING
LIVING/
SLEEPING
SLEEPING
LIVING/
SLEEPING
LIVING/
113 114
SLEEPING
LIVING/
SLEEPING
LIVING/
VEST
STAIR-3
FOR MUD ROOM
CEILING EXHAUST FAN
S-2:150x100
1,190 CMH
R-1:500x250
50 CMH
10x
E-1:300x300
340 CMH
2x
CEILING EXHAUST FAN
238 CMH
S-3:1,800x2ST
FOR TOILET
238 CMH
4x
F
F
T.V.
R-1:750x400
1,240 CMH
510 CMH
x2
WALL CAP
WALL CAP
150x100
400x200
1,190 CMH
R-1:500x250
100 CMH
E-1:150x150
R-1:650x400
1,000 CMH
T T T T T T T T T T T T
T T T T T T T T
T
50 CMH
S-2:150x100 10x
595 CMH
X2
S .A
PARTIAL PLAN250 CMH
5x
E-2:350x350
595 CMH
T.V.
340 CMH
V.D. V.D.
T
AT CEILING)
T.V.
S .A
DN
340 CMH
x2
M13
SEE MECH. RM. DUCT
PARTIAL PLAN
M13
SEE LAUNDRY RM. DUCT
THERMOSTAT W/NEW.(MOUNT BULB
AIR DUCT WITH NEW
REPLACE ALL EXISTING EXHAUST DUCT
WITH NEW(TYP)
REPLACE ALL EXISTING SUPPLY
REPLACE EXISTING NIGHT SET BACK HEATING
F.D.
800x200
150x100 150x100
400x200
150x150
150x100
550x150
150x100
300x200
300x150
150x100 150x100
550x150550x150
150x100
550x150 x
350x150
250x150
250x150
350x200 250x150
300x200
250x150
300x100 250x100
300x150
400x200
V.D. V.D.
250x100
150x100
400x250
600x500
900x300
250x100
150x100 400x200
S.A.:500x150
S .A
S.A.:1,200x300
250x100
150x100150x100
550x150
150x100
150x150
S.A.:400x200
550x150
150x100
800x200
150x100
550x150
DUCT SIZE:900x300
INSULATION SIZE:1,000x400
S.A.:1,200x300 S.A.
S.A.:900x300
T.V.
900x300
F.D.
600x500
V.D.
250x200
200x150
220 CMH
x2
UP DN
300x150
UP
B/B
FEC
V
D
D
V
D
D
COUNTER
W W W W
COUNTER
COUNTER
COUNTER
W W W W
HOSE
BIB
WW W
D
D
D
D
D
D
WW W
FEC
UP
T
T
F.D.
T.V.
T
NH T
T.V.
EF
EF
EF
EF
EF
EF
EF
EF
EF
EF
EF
EF
EF
EF
EF
EF
EF
EF
EF
EF
1. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE AND
DIRECTION OF DUCTWORKS IN FIELD (TYP.).
2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR DUCTWORK
PRIOR TO DUCTWORK INSTALLATION.
NOTES:
REPAIR BARRACKS S-827
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
MECHANICAL
M-11
SCALE : 1 / 100
HVAC DUCT PLAN (2ND-3RD FLOOR)
M11
HVAC DUCT PLAN(2ND-3RD FLOOR)
AND NOTES
CORRIDOR
2ND FL : KITCHEN
3RD FL : LOUNGE 325
STORAGE
STAIR-1
STORAGE
SLEEPING
LIVING/
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
STAIR-2
STAIR-3
VEST.
VEST.
COMM.
327 227
JAN.
SLEEPING
LIVING/
SLEEPING
LIVING/
235 335
1,190 CMH
R-1:500x250
S-2:150X100
50 CMH
12x
E .A
E-1:300x300
340 CMH
E-2:350x350
595 CMH
COUNTER & CABINET @2ND FL. ONLY
S-2:400x400
985 CMH
x2
R-1:1000x500
1,970 CMH
S-2:150x100
50 CMH
12x
E .A
R-1:500x250
1,190 CMH
E .A
595 CMH
x2
T T T T T T T TT T T T
T
T T T T T T T T T T T T
T x2
595 CMH
220 CMH
x2
E .A
E .A
E .A
E .A
E .A
E .A
E .A
E .A
E .A
E .A
RH
RANGE HOOD
DUCT WITH NEW (TYP)
REPLACE ALL EXISTING SUPPLY AIR
REPLACE ALL EXISTING EXHAUST DUCT
WITH NEW (TYP)
V.D. V.D.
450x250 F.D.
600x480
S .A
DN UP
D.S
UP
DN
FECFEC
UP DN
REFREF
F.D.
F.D.
EF
EF
EF
EF
EF
EF
EF
EF
EF
EF
EF
EF
EF
EF
EF
EF
EF
EF
EF
EF
EF
EF
EF
EF
1. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE AND
DIRECTION OF DUCTWORKS IN FIELD (TYP.).
2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR DUCTWORK
PRIOR TO DUCTWORK INSTALLATION.
NOTES:
REPAIR BARRACKS S-827
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
MECHANICAL
M-12
SCALE : 1 / 100
HVAC DUCT PLAN (4TH FLOOR)
M12
HVAC DUCT PLAN(4TH FLOOR) AND NOTES
CORRIDOR
4TH FL : GAME ROOM
STORAGE
STAIR-1
STORAGE
SLEEPING
LIVING/
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
STAIR-2
STAIR-3
VEST.
VEST.
COMM.
JAN.
SLEEPING
LIVING/
SLEEPING
LIVING/
S-2:150x100
50 CMH
12x 340 CMH
E .A
2x
E .A
E-1:300x300
E .A
340 CMH
E-2:150x150
100 CMH
R-1:500x250
1,190 CMH
S-2:150x100
50 CMH
E .A
812 CMH
S-2:300x300 2x
1,624 CMH
R-1:750x400
T.V.
FROOF EXHAUST
FAN
ROOF EXHAUST
FAN 5
F
2x
220 CMH
F
ROOF EXHAUST
FAN
ROOF EXHAUSTF
5 FAN
ROOF EXHAUST
F
FAN
x 12
T T T T T T T T T T T T
T
TT
T
T T T T T T T T T T
E-2:350x350
595 CMH
200x200 GOOSENECK
GOOSENECK
W/BIRDSCREEN
W/BIRDSCREEN
595 CMH
x2
E .A
E .A
E .A
E .A
E .A
T.V.
E .A
E .A
T.V.
E .A
T.V.
E .A
DUCT WITH NEW (TYP)
REPLACE ALL EXISTING EXHAUST
DUCT TO BE REMAINED (TYP)
REPLACE ALL EXISTING SUPPLY AIR
600O EXHAUST AIR
450x250
600x500
S .A
150x100
550x150 150x100
150x550
(TYP.)
S.A.:400x200
800x200
150x100 550x150
150x100
250x150
150x150
250x150
300x200
E.A.:300x200
150x100
150x100
150x100 150x100
150x100
250x150
350x150
E.A.:300x200
150x100
550x150 550x150
150x100 150x100
250x150
S.A.:300x150
200x150
450x250 250x200
350x150
500x150 500x200
800x200
550x150 150x100
250x150 250x150
150x100
150x100
150x150
250x150
150x100
550x150
300x200 x
350x140 x
550x150
300x200 150x100
150x100
250x150
800x200
150x100
200x150
400x250
600x500
DN UP
UP
DN
FEC
FECFEC
UP DN
T.V.
E .A
E .A
T.V.
T.V. T.V. T.V. T.V. T.V.
T.V.
T.V.
T.V.
T.V.T.V.
EF
EF
EF
EF
EF
EF
EF
EF
EF
EF
EF
EF
EF
EF
EF
EF
EF
EF
EF
EF
EF
EF
EF
EF
1. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE AND
DIRECTION OF DUCTWORKS IN FIELD (TYP.).
2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR DUCTWORK
PRIOR TO DUCTWORK INSTALLATION.
NOTES:
REPAIR BARRACKS S-827
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
MECHANICAL
M-13
350 x 350 : E-1
WALL EXHAUST FAN
3,570 CMH
FOR CONT.
SEE HVAC DUCT PLAN1
SEE HVAC DUCT PLAN
F
O .A
X
DT
ELEC. SPACE
P
ET
E.A.
MECH. ROOM
HVU
S .A x x
M
S D
M
FOR CONT.
HVU
AHU
(SIZE=1,800 x 1,700)
(SIZE=650 x 1000)
W W
D D
D D
W WW
WW
D
DD
D D
TV
HT
W W WW W WW
CONN. TO
2ND. FL.
F.D.
FOR LAUNDRY ROOM
DRYER EXHAUST FAN
LAUNDRY
SEE HVAC
S-2:500x500
1,700 CMH
x4
E-1:850x600
3,400 CMH
x2
1-500x500)
PANEL FILTER(2-EA, 1-400x500 &
PERMANENT AND CLEANASLE
FILTER SHALL BE DRY TYPE
WITH BORDER FRAME
CLEANABLE LINT FILTER
HANDLE
(TYPICAL)
FILTER HOLDING FRAME
AND FRAME
BETWEEN FILTER
NEOPRENE GASKET
(TYPICAL)
CORNER LATCH
ROTARY WEDGE
DUCT PLAN
DUCT PLAN
SEE HVAC
SCALE : 1 / 50
3 LINT FILTER DETAIL
NOT TO SCALE
SCALE : 1 / 50
2 LAUNDRY RM. DUCT PARTIAL PLAN(1ST. FL)
M13
M13
M13
M10
M10
MECH. ROOM DUCT PARTIAL PLAN
F
(SIZE=150 x 1000)
DUCT OPENING
REPLACE LINT
FILTER
W/ NEW. 300Dx2,700Wx2,300H
LOUVER W/ BIRDSCREEN W/NEW.
DUCT OPENING W/ BIRDSCREEN W/NEW.
FOR MECH. ROOM VENT W/NEW.
DAMPER W/ NEW.(TYPICAL)
THERMOSTAT W/NEW.
SET AT 4.4 C(TYPICAL)
MECH. ROOM DUCT PARTIAL PLAN,
LAUNDRY RM. DUCT PARTIAL PLAN(1ST. FL)
REPLACE EXISTING OUTSIDE AIR INTAKE
REPLACE EXISTING AIR PLENUM
F.D.
REPLACE EXISTING OUTSIDE AIR INTAKE
REPLACE EXISTING COMBUSTION AIR INTAKE W/NEW
REPLACE EXISTING MOTORIZED DAMPER
REPLACE EXISTING FREEZESTAT W/NEW.
REPLACE EXISTING HEATING
F.D.
W/INSULATION W/NEW.(TYP)
REPLACE ALL EXISTING DUCT
REPLACE EXISTING O.A. MOTORIZED
REPLACE EXISTING VENT. THERMOSTAT
REPLACE EXISTING O.A. MOTORIZED
DAMPER W/NEW.
REPLACE EXISTING SMOKE
DETECTOR W/NEW.
M10
M10
DUCT W/ NEW.(TYP.OF 20)
LINT FILTER DETAIL AND NOTES
NOT TO SCALE
M13
4 SECTION
S .A x
F.D.
T
TH
C
S.A.:300 x 1200
S.A.:150 x 500
STORAGE
STORAGE
AIR PLENUM
(SIZE=1000 x 650)
W/ BIRDSCREEN
(SIZE=1000 x 150)
300Dx2,700Wx2,300H
OUTSIDE AIR INTAKE DUCT OPENING
COMBUSTION AIR INTAKE DUCT OPENING
W/ BIRDSCREEN
(SIZE=1,700 x 1,800)
OUTSIDE AIR INTAKE LOUVER
500x1,000
S.A.:1200 x 300
FOR MAKE-UP AIR
AIR HANDLING UNIT
AHU
S.A.:300 x 1200
F.D.
T.V.
F.D.
T.V.
T.V.
T.V.
O.A.
MECH. ROOM
M
600x650
M
O.A.
H & V UNIT
FOR MUD ROOM AREA
FOR LAUNDRY AREA
H & V UNIT
HVU
HVU
VT T
M
SD
H
FRT
C
TH
C
S.A.M H
FRT
C T FR
O.A.
HEATING BOILERS(6SETS)
REMOVE & REINSTALL EXISTING
FLU VENT AND WIRING WIRH NEW.
REPLACE EXISTING RACK, GAS PIPING,
ASSOCIATED ACCESSORIES.
ADD HEATING BOILER(1SET) AND
DOMESTIC HOT WATER HEATERS(4SETS)
REMOVE & REINSTALL EXISTING
FLU VENT AND WIRING WIRH NEW.
REPLACE EXISTING RACK, GAS PIPING,
AND ASSOCIATED ACCESSORIES.
ADD DOMESTIC HOT WATER HEATER(1SET)
1. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE AND
DIRECTION OF DUCTWORKS IN FIELD (TYP.).
2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR DUCTWORK
PRIOR TO DUCTWORK INSTALLATION.
NOTES:
NOTE ON EXISTING GAS BOILER & HOT WATER HEATER
CONTACT INFORMATION OF KYONGDONG IS MR, SHIN, DONGIK/TEL NO. ; 010-4175-1111
THE NECESSARY ACTIONS TO PROTECT THE SYSTEM BASED ON THEIR ADVICE.
BEFORE STARTING CONSTRUCTION TO INFORM THE CONSTRUCTION SCHEDULE AND TAKE ALL
THE CONTRACTOR MUST CONTACT THE BOILER & HEATER MANUFACTURER "KYONGDONG NAVIEN"
REPAIR BARRACKS S-827
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
MECHANICAL
M-14
M14
MAKE UP
ASSEMBLY
BACK FLOW PREVENTER
SET AT 0.84KG/CM
PRESSURE REDUCING VALVE
OUTDOOR AIR THERMOSTAT
W/REMOTE BULB
SUNSHIELD
H
CIRC.PUMP
CHILLED/HOT WATER
CHR
CHS
C H
S
H W
R
C H
R
AS
E.A.
AIR SEPARATOR
P
C/HWR
C/HWS
FROM/TO BLDG. HEATING
AND COOLING SYSTEM
ET
CHILLED/HOT WATER
EXPANSION TANK
HWS
HWR
PIPING LINE
COLD WATERCIRC.PUMP
HOT WATER
P
SYSTEM ZONE
TO HEATING
0-100 DEG. RANGE
TO MAKE ON FALL IN TEMP
V-1
V-1
V-2 V-2
TO
SUNSHIELD
OT
C
OUTDOOR AIR THERMOSTAT
W/ REMOTE BULB
WIRE TO MAKE ON RISE
RANGE)
IN TEMP(0-100 DEG. C
STARTER
STARTER
FS
HOT / CHILLED WATER FLOW SYSTEM DIAGRAM
NOT TO SCALE
H W
S
HOT WATER BOILER
GAS FIRED CONDENSING
TO BE REMAINED
O
SENSOR (PT1000)
T
O.A. TEMP.
EXISTING SUNSHIELD
H W
R
TO BE REMAINED
AIR COOLED
WATER CHILLER POSITION
V - 1
V - 2
VALVE
OPEN
WINTERSUMMER
CLOSED
OPEN CLOSED
VALVE SCHEDULE
APPROPRIATE SWITCHOVER VALVES SHALL BE MANUALLY OPEN/CLOSED
1.1
1.
3.
WINTER SEASON
STARTS AND RUNS CONTINOUSLY WHEN O.A. THERMOSTAT DROPS BELOW
SET PUMP P-1 "HAND-OFF-AUTO" SWITCH TO "AUTO" POSITION, PUMP
IT'S SETPOINT OF 15.6 DEG.C.
SUMMER-WINTER SWITCHOVER
ACCORDINGLY AS PER SEASON REQUIREMENTS.
SEQUENCE OF OPERATION
1.2
2. CHILLED WATER SYSTEM:
2.1
STARTS AND RUNS CONTINOUSLY WHEN O.A. THERMOSTAT RISES ABOVE
SET PUMP P-1 "HAND-OFF-AUTO" SWITCH TO "AUTO" POSITION, PUMP
IT'S SETPOINT OF 21.1 DEG.C.
2.2
CLOSES IT'S CONTACT UPON SENSING FLOW AND P-1 IS ENERGIZED.
CHILLER CONTROL SYSTEM IS ENERGIZED WHEN PIPELINE FLOW SWITCH
CHILLER BUILT-IN CONTROL MAINTAIN CHILLED WATER SUPPLY TEMP.
AT -6.7 DEG.C.
S
SMOKE
DETECTOR
TO HVAC SYSTEM
M
FOR OUTSIDE AIR
SA
OA
OUTSIDE AIR
INTAKE LOUVER
SYSTEM "ON-OFF"
SWITCH
OA MOTORIZED
DAMPER, N.C.,
EAC/H
C
ROOF EXHAUST
TC
SW
W/BIRDSCREEN
DUCT MOUNTED
COOLING THERMOSTAT
WITH AVERAGING ELEMENT,
EA
OA
FANS
AIR HANDLING UNIT
C /H
W R
C /H
W S
HEATING THERMOSTAT
WITH AVERAGING ELEMENT,
FR
T
FREEZESTAT
M
FACE & BY-PASS
DAMPER
(SPRING RETURN MOTOR)
F
N.O.
N.C.
AUTOMATIC CHANGEOVER SWITCH
STARTER
M
DUCT MOUNTED
STARTER
TH
EA
EA
AHU-1 SEQUENCE OF OPERATION
AND BELOW THE COOLING THERMOSTAT TC MODULATES THE FACE AND
BY-PASS DAMPER MOTOR TO MAINTAIN THE LEAVING AIR TEMP AT
1. WHEN AHU-1 MOTOR RUNS, FAN MOTOR AUXILLARY CONTACT CLOSES
FAN F-5 SHALL BE DE-ENERGIZED AND THE O.A. DAMPER SHALL CLOSE.
2. WHEN SMOKE DETECTOR SENSES SMOKE, AHU FAN MOTOR AND ROOF
COOLING AND HEATING
1. THE AIR HANDLING UNIT MOTOR SHALL BE MANUALLY ENERGIZED AND
FAN AND ROOF EXHAUST FAN SHALL BE DE-ENERGIZED AND THE O.A.
GENERALA.
B.
RUN CONTINUOUSLY. WHEN THE UNIT IS CALLED TO RUN,
THE OUTSIDE AIR DAMPER SHALL OPEN.
WHEN THE OUTSIDE AIR DAMPER IS OPEN, A DAMPER MOUNTED END
TO BE ENERGIZED.
SWITCH SHALL CLOSE ALLOWING THE MOTOR STARTER HOLDING COIL
4. THE TOILET EXHAUST FANS SHALL BE ELECTRICALLY INTERLOCKED WITH
AHU-1.
DAMPER SHALL CLOSE.
TO ENERGIZE AQUASTAT.
BY-PASS DAMPER MOTOR TO MAINTAIN THE LEAVING AIR TEMP AT
AND ABOVE HEATING THERMOSTAT TC MODULATES THE FACE AND
M14
AIR HANDLING UNIT SYSTEM CONTROL DIAGRAM
NOT TO SCALE
HOT/CHILLED WATER FLOW SYSTEM
DIAGRAM, AND AIR HANDLING UNIT
SYSTEM CONTROL DIAGRAM
SET BOILER B-1 CONTROLLER TO AUTO POSITION, BOILER
STARTS WHEN PT-1000 DROPS BELOW IT'S SETPOINT OF 15.6 DEG.C.
REPAIR BARRACKS S-827
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRO…