Attachment II- Revised SOW (Redline Changes).pdf
PDF 3 MB Posted
- Attached to
- CONUS Laboratory Testing Federal contract opportunity
- Solicitation number
- SPE60321R0508
- Issued by
- Defense Logistics Agency Energy
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| SF30_SPE60321R05080004.pdf | ||
| Attachment 1-SOW 12 July 2021.pdf | ||
| Attachment 1-SOW (12 July 2021).pdf | ||
| SF30_SPE60321R05080003.pdf | ||
| SF30_SPE60321R05080002.PDF | ||
| Attachment III- Revised Price Sheet.xlsx | XLSX spreadsheet | |
| Attachment II- SOW-CONUS Lab (6 July 2021).pdf | ||
| Attachment I-CONUS Lab Responses.pdf | ||
| SF30_SPE60321R05080001.PDF | ||
| Attachment 2 - ENERGY QAP E34.pdf | ||
| Attachment 1 - SOW CONUS LAB.pdf | ||
| Attachment 6 - DOL WAGE DETERMINATIONS.pdf | ||
| Attachment 4 - PAST PERFORMANCE REFERRAL LIST.pdf | ||
| Attachment 3 - LAB TESTING PRICE SHEET.xlsx | XLSX spreadsheet | |
| RFP SPE60321R0508 CONUS LAB.pdf | ||
| Attachment 7 - DLA FORM 2019-SUBK PLAN.pdf | ||
| Attachment 5 - PAST PERFORMANCE QUESTIONNAIRE.pdf |
Show all 17
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
file://NoURLProvided[7/9/2021 10:44:09 AM]
Styling and Annotations
385 Styling
0 Annotations
7/9/2021 10:44:09 AM
Compare Results
Total Changes
Content
178 Replacements
411 Insertions
210 Deletions
Go to First Change (page 1)
Old File:
Attachment 1 - SOW CONUS LAB.pdf
23 pages (706 KB)
5/17/2021 11:34:35 AM
versus
New File:
Attachment II- SOW-CONUS Lab (6 July 2021).pdf
27 pages (736 KB)
7/7/2021 11:10:22 AM
Statement of Work for
Contracted Laboratory Services
CONUS
6 July 2021
Text Replaced� Text [Old]: "17 May" [New]: "6 July"
Contents C-1.0 General Description:
C-1.0.1 Service Locations: When ordered, C-1.1 Facilities:
C-1.2 Specifications, Standards and Handbooks:
C-1.3 Scheduling of Services:
C-2.0 Contract Deliverables:
C-2.1 Contract Compliance Plan:
C-2.2 Laboratory Test Reports:
C-2.3 Contract Contingency Plan:
C-2.4 Contract Training Plan:
C-2.5 Safety Plan:
C-2.6 Transportation Plan:
C-2.7 Laboratory Equipment Plan:
C-2.8 Monthly Reporting:
C-3.0 Laboratory Requirements:
C-3.1 Operating Hours:
C-3.2 Staffing:
C-3.3 Knowledge and Skills:
C-3.4 Access:
C-3.5 Equipment Calibration:
C-3.6 Epoxy Lined Sample Cans:
C-3.7 Ellipsometric Tube Deposit Rater (ETR):
C-3.8 Turn-around Times:
C-3.8.1 Baltimore, MD Area:
C-3.8.2 Selby, CA Area:
C-3.8.3 Houston, TX Area:
C-3.9 Retain samples:
C-4.0 Transportation Performance Requirements:
C-5.0 Secured Fuels Performance Requirements:
C-6.0 Surveyor Duties:
C-6.1.1 Third party witness:
C-6.1.2 Sampling of petroleum products:
C-6.1.3 Gauging of petroleum products:
C-6.1.4 Cargo Inspection of petroleum products:
C-7.0 Sample Shipment:
Attachment 1: Products Attachment 2: Series Testing Requirements Attachment 3: Approved Testing Methods
Text Replaced� Text [Old]: "......................................................................................................................................................"
[New]: "............................................................................................................................................................."
Text Replaced� Text [Old]: "..............................................................................................................................."
[New]: "....................................................................................................................................."
Text Replaced� Text [Old]: "C-1. 1 Facilities: ......................................................................................................................................................................."
[New]: "C-1.1 Facilities: ..............................................................................................................................................................................."
Text Replaced� Text [Old]: "C-1. 2" [New]: "C-1.2"
Text Replaced� Text [Old]: "......................................................................................................................"
[New]: "..........................................................................................................................."
Text Replaced� Text [Old]: "C-1. 3" [New]: "C-1.3"
Text Replaced� Text [Old]: ".................................................................................................................................................."
[New]: "........................................................................................................................................................."
Text Replaced� Text [Old]: "C-2. 0 Contract Deliverables: ...................................................................................................................................................."
[New]: "C-2.0 Contract Deliverables: ..........................................................................................................................................................."
Text Replaced� Text [Old]: "C-2. 1" [New]: "C-2.1"
Text Replaced� Text [Old]: "............................................................................................................................................."
[New]: "..................................................................................................................................................."
Annotation Attributes Changed� Annotation
[Old]: "C-2. 2" [New]: "C-2.2"
Text Replaced� Text [Old]: "............................................................................................................................................... 1" [New]: "...................................................................................................................................................... 2"
[Old]: "C-2. 3" [New]: "C-2.3"
Text Replaced� Text [Old]: "............................................................................................................................................"
[New]: ".................................................................................................................................................."
[Old]: "C-2. 4" [New]: "C-2.4"
Text Replaced� Text [Old]: ".................................................................................................................................................."
[New]: "........................................................................................................................................................."
[Old]: "C-2. 5 Safety Plan: ...................................................................................................................................................................."
[New]: "C-2.5 Safety Plan: ..........................................................................................................................................................................."
[Old]: "C-2. 6 Transportation Plan: ......................................................................................................................................................."
[New]: "C-2.6 Transportation Plan: .............................................................................................................................................................."
[Old]: "C-2. 7" [New]: "C-2.7"
Text Replaced� Text [Old]: "..........................................................................................................................................."
[New]: "................................................................................................................................................."
[Old]: "C-2. 8 Monthly Reporting: ........................................................................................................................................................"
[New]: "C-2.8 Monthly Reporting: ..............................................................................................................................................................."
[Old]: "C-3. 0 Laboratory Requirements: .............................................................................................................................................."
[New]: "C-3.0 Laboratory Requirements: ....................................................................................................................................................."
[Old]: "C-3. 1 Operating Hours: ............................................................................................................................................................"
[New]: "C-3.1 Operating Hours: ..................................................................................................................................................................."
[Old]: "C-3. 2 Staffing: ........................................................................................................................................................................."
[New]: "C-3.2 Staffing: ................................................................................................................................................................................."
[Old]: "C-3. 3" [New]: "C-3.3"
Text Replaced� Text [Old]: "...................................................................................................................................................."
[New]: ".........................................................................................................................................................."
[Old]: "C-3. 4 Access: .........................................................................................................................................................................."
[New]: "C-3.4 Access: .................................................................................................................................................................................."
Text Replaced� Text [Old]: "C-3. 5 Equipment Calibration: .................................................................................................................................................."
[New]: "C-3.5 Equipment Calibration: ........................................................................................................................................................."
Text Replaced� Text [Old]: "C-3. 6" [New]: "C-3.6"
Text Replaced� Text [Old]: "............................................................................................................................................."
[New]: "..................................................................................................................................................."
Text Replaced� Text [Old]: "...................................................................................................................."
[New]: "........................................................................................................................."
Text Replaced� Text [Old]: "......................................................................................................................................................."
[New]: ".............................................................................................................................................................."
Text Replaced� Text [Old]: ".................................................................................................................................................."
[New]: "........................................................................................................................................................"
Text Replaced� Text [Old]: "........................................................................................................................................................."
[New]: "................................................................................................................................................................"
Text Replaced� Text [Old]: "....................................................................................................................................................."
[New]: "............................................................................................................................................................"
[Old]: "C-3. 9 Retain samples: .............................................................................................................................................................. 3" [New]: "C-3.9 Retain samples: ..................................................................................................................................................................... 4"
[Old]: "C-4. 0" [New]: "C-4.0"
Text Replaced� Text [Old]: "...................................................................................................................."
[New]: ".........................................................................................................................."
[Old]: "C-5. 0" [New]: "C-5.0"
Text Replaced� Text [Old]: "....................................................................................................................."
[New]: "..........................................................................................................................."
[Old]: "C-6. 0 Surveyor Duties: ............................................................................................................................................................"
[New]: "C-6.0 Surveyor Duties: ..................................................................................................................................................................."
[Old]: "....................................................................................................................................................."
[New]: "..........................................................................................................................................................."
[Old]: "................................................................................................................................."
[New]: "......................................................................................................................................."
[Old]: ".................................................................................................................................."
[New]: "........................................................................................................................................"
[Old]: "......................................................................................................................"
[New]: "..........................................................................................................................."
[Old]: "C-7. 0 Sample Shipment: .........................................................................................................................................................."
[New]: "C-7.0 Sample Shipment: ................................................................................................................................................................."
[Old]: ".................................................................................................................................................................."
[New]: ".........................................................................................................................................................................."
Text Replaced� Text [Old]: "..................................................................................................................................."
[New]: "........................................................................................................................................."
Text Replaced� Text [Old]: ".................................................................................................................................... 16" [New]: ".......................................................................................................................................... 19"
Page | 1
C-1.0 General Description: This Statement of Work (SOW) provides the requirements for laboratory testing services in multiple locations throughout the Continental U.S. (CONUS) region. The Contractor will be responsible for the laboratory testing of government-owned petroleum products in accordance with the specifcations as described herein, and transportation of samples from contracted locations to the contractor’s laboratory. Government-owned products mentioned in this SOW may be shipped to the Contractor’s laboratory for testing.
C-1.0.1 Service Locations: When ordered, the contractor shall be able to provide services required in this SOW to DLA Energy in each of the locations listed below. Contractor facilities must be located within the CONUS region and meet the required turn-around times listed in paragraph C-3.8.
Americas East Locations Helena, AL Columbus,GA NY Harbor Area Montgomery, AL Chicago, IL Coraopolis, PA Moundville, AL Baton Rouge, LA Charleston, SC Jacksonville, AR Boston, MA Rapid City, SD Port Mahon, DE Portland, ME Dallas, TX Port Everglades, FL Anacostia, MD Houston, TX Key West, FL Andrews AFB, MD Craney Island, VA Jacksonville, FL Baltimore, MD Norfolk, VA Tampa, FL Lockhart, MS Yorktown, VA Macon, GA Selma, NC Bremen, GA Jacksonville, NJ
Americas West Locations
Carson, CA Moffett Field, CA Alamogordo, NM Colton, CA McClellan, Park, CA Las Vegas, NV NAS Lemoore, CA Selby, CA Salt Lake City, UT NAS Point Loma, CA Denver, CO Puget Sound, WA
C-1.1 Facilities: The contractor shall have facilities that meet the required turn-around times in section C-3.8. The contractor shall provide the location(s) of the facility where the product shall be tested, facility testing capabilities and contact information.
C-1.2 Specifications, Standards and Handbooks: At each laboratory, the contractor shall retain a copy of all required specifications, standards, test methods, handbooks, etc., per this SOW and perform services in accordance with testing requirements. Military Specifications referenced in Attachment 1 for petroleum product types can be obtained at http://quicksearch.dla.mil or https://assist.dla.mil but can also be requested in writing to the Contracting Officer (CO) or Contracting Officer’s Representative (COR).
C-1.3 Scheduling of Services: After the CO authorizes a task order, the COR or QAR will contact the laboratory to schedule the testing. The contractor shall not perform services under this SOW without a task order or direct authorization from the CO. If a task order was not received, the contractor shall contact the CO or COR prior to any testing. Only the CO can formally, either in writing or verbally, authorize testing and create an obligation.
C-2.0 Contract Deliverables: All plans shall be submitted to the CO for review and acceptance as a part of the technical proposal as documented in the solicitation. Plans shall be kept current for the life of the contract. The government reserves the right to request changes or modifications to any detailed plans at any time throughout the contract performance period. Plans shall be made available for Government review upon request at any time during the contract performance period.
C-2.1 Contract Compliance Plan: The contractor is responsible for compliance with all contract performance requirements. The contractor is responsible for all actions taken by any sub-contractor utilized under this contract. The contractor shall be ISO 9001 and/or ISO/IEC 17025 certified.
[Old]: "specifications" [New]: "specifcations"
Page | 2
C-2.2 Laboratory Test Reports: The contractor shall maintain records evidencing all analysis performed under this contract. All samples tested shall be documented with a detailed report. Reports shall be complete and legible containing information pertaining but not limited to: Lab Name, Test Method, Test Name, Test Results, Test Units, Test Limits.
Reports not containing the appropriate information will need to be corrected and resubmitted by the contractor for approval.
C-2.3 Contract Contingency Plan: The Contract Contingency Plan shall outline contractor actions to ensure there is no significant interruption of services resulting from labor disputes, catastrophic failure of equipment, or the effects of natural disasters/emergencies. The plan shall provide specific details regarding labor issues that may result from potential strike actions, world events, world actions, military contingency and war time manning requirements.
C-2.4 Contract Training Plan: The contractor shall provide a detailed plan that identifies employee training requirements and procedures necessary to maintain proficiency. The plan shall identify length of training, training sources and a brief description of courses such as safety, environmental protection and job qualification training. The contractor is responsible for ensuring all individual training requirements are accomplished. The contractor must demonstrate current participation in a proficiency program or suitable means to verify laboratory performance.
C-2.5 Safety Plan: The contractor shall provide a detailed plan outlining the policy, procedures and actions necessary to maintain a safe working environment for employees and visitors. The plan shall cover the products stored, handled, Safety Data Sheets (SDS) and guidelines regarding the safe handling of such products and shall be maintained and updated over the course of the contract.
C-2.6 Transportation Plan: The contractor is required to submit a plan for review to transport the petroleum samples to an approved laboratory for testing or shipping (contractor supplied transport, third party delivery service, etc.) and how they plan on tracking the chain of custody to the contractor’s facility. Product quality must be preserved and not altered by shipment. DLA Energy or it’s subcontractor(s) do not have the ability or certification to ship or package fuel samples.
C-2.7 Laboratory Equipment Plan: The contractor will furnish, and update annually, to the CO and COR the status by name, model and serviceability of all equipment used in laboratory testing. Equipment that malfunctions or is non-serviceable shall be reported to the CO and COR within 48 hours with a mitigation plan to provide testing capability.
C-2.8 Monthly Reporting: The contractor shall provide a monthly written report to the CO and COR with the number of laboratory tests performed, what testing was included and the location.
C-3.0 Laboratory Requirements: The below are general requirements for all contractor laboratories. Laboratories are required to have the listed referee test methods which is referenced in the product specifications and international test methods (ASTM, EI, etc.).
C-3.1 Operating Hours: The contractor shall be responsible for adjusting hours of operation to meet workload demands and turn-around times in section C-3.8.
C-3.2 Staffing: The contractor shall provide sufficient staffing to accomplish all functions and tasks to include simultaneous operations of performing multiple tests at a time, and provide the contact information for laboratory manager or assistant laboratory manager if the laboratory is not manned 24 hours, seven days a week.
C-3.3 Knowledge and Skills: The contractor shall ensure that personnel assigned to all tasks have the requisite knowledge and skills to meet the performance standards and comply with all applicable federal laws, state laws, regulations, and codes. All supervisors and key employees shall be able to read and understand English so they can understand and follow oral or written instructions directions, directives, regulations, and operating procedures. All supervisors and contractor key employees shall be capable of writing in English to compose the required detailed reports.
C-3.4 Access: The contractor shall allow DLA Energy representatives to witness testing or sampling. It shall provide the applicable information for access, provide follow-up to obtain access (for personnel and vehicles) to all facilities that product is tested or sampled. For areas that require special admission the contractor will assist gaining access.
Page | 3
C-3.5 Equipment Calibration: The laboratories shall have a system of calibration equivalent to ISO/IEC 17025.
All testing shall be performed in accordance with the appropriate international or local test methods approved for use by DLA Energy and listed in this SOW.
C-3.6 Epoxy Lined Sample Cans: The contractor shall maintain a supply of 10 unused epoxy lined fuel sample shipping containers to be provided to DLA Energy personnel per request. Sample containers shall be stored to ensure they are clean and free from all substances that might contaminate the product being sampled. Containers must meet the following specifics: Complies with ASTM D-4306, height not to exceed 9 inches, diameter not to exceed 7 inches, capacity 1 USG, Bung Plug ¾” with lock-wire hole, carrying handle able to be shipped as hazardous material.
C-3.7 Ellipsometric Tube Deposit Rater (ETR): The contractor shall perform ASTM D3241 Annex 3 ETR within the testing turn-around times in section C-3.8 Sample Testing Turnaround Times. ETR is the preferred method and shall be treated as the referee method.
C-3.8 Turn-around Times: The contractor shall perform testing in accordance with the turn-around times listed in the table below. Turn-around time starts when the contractor is notified that the sample is prepared for transportation from sample location to the servicing laboratory. Turn-around time ends when testing results are completed and delivered to DLA Energy. DLA-Energy will give the contractor at least 12 hours of advance notice ofthe sample being prepared for shipment (turn-around time start) (prime contractor is responsible for any sub-contractor actions). The 12 hours of advance notice is not included in the turn-around time. If testing cannot be completed within the turn-around time the contractor will immediately notify the CO and COR. The contractor shall specify the problem and the estimated completion date and time. If there is a need for an expedited test, it will be a maximum turn-around time of 18 hours unless otherwise stated in C-3.8.1, C-3.8.2, or C-3.8.3.
C-3.8.1 Baltimore, MD Area: Mission requirements dictate a turn-around time for Jet A petroleum sample(s) to be tested at this location. Jet A sample results must be received within 16 hours. The 16-hour turn-around starts when the sample is prepared for transportation at the location and the contractor is notified for sample pickup. DLA Energy will provide the contractor an initial forecast then a 24-hour notification prior to sample collection as times can be adjusted by weather, berthing space or ullage.
C-3.8.2 Selby, CA Area: Mission requirements dictate a turn-around time for Jet A and F-76 petroleum sample(s) to be tested at this location. Sample results for Jet A shall be received within 8 hours and for F-76 must be received within 24 hours unless otherwise coordinated with the QAR. DLA Energy will provide the contractor an initial forecast and notification of 24-hours prior to sample collection as times can be adjusted by weather, berthing space or ullage. The turn-around starts when the sample is prepared for transportation at the storage location and the contractor is notified for sample pickup.
C-3.8.3 Houston, TX Area: Mission requirements dictate a turn-around time for Jet-A petroleum sample(s) to be tested at this location. When an expedited Jet-A request is made, sample results shall be received within 8 hours unless otherwise coordinated with the QAR. DLA Energy will provide the contractor an initial forecast and notification 12 hours prior to sample collection as times can be adjusted by weather, berthing space or ullage. The turn-around time starts when the sample is prepared for transportation at the storage location and the contractor is notified for sample pickup.
Maximum Turn-around Hours Chart A Series 48 hours B Series 36 hours C Series 24 hours
Individual tests 24 hours Expedite 18 hours
Secured Fuel Performance 8 hours
Page | 4
C-3.9 Retain samples: After analysis, the contractor shall retain samples for a minimum of 45 days. In the event of a suspected quality issue or dispute, a longer sample retention period may be requested by DLA Energy. The contractor shall be responsible for disposal of excess fuel samples and sample containers.
C-4.0 Transportation Performance Requirements: The contractor shall be responsible for packing and transporting all petroleum samples from a job site to the laboratory in accordance with federal and laws and regulations. When requested by DLA Energy personnel, the contractor shall be able to provide an epoxy line sample can, detailed in C-3.6 for replacement. When sample transportation is not required of the contractor, they shall be notified in advance.
C-5.0 Secured Fuels Performance Requirements: Due to mission demands DLA Energy shall request petroleum testing under Attachment 2 from MIL-STD-3004-1 table XII. DLA-Energy will provide the contractor with as much advance notice as possible as the turn-around time shall not exceed 8 hours after receipt of sample at the laboratory.
Specifics/logistics shall be scheduled by the QAR after a task order for the secured fuels testing services is issued.
C-6.0 Surveyor Duties: When ordered, the contractor shall represent DLA Energy to ensure all specifications, regulations, ASTM, API MPMS are followed when a DLA Energy representative is not available at locations mentioned in C-1.0.1. Personnel shall be International Federation of Inspection Agencies or TIC council or equivalent certified to perform the duties defined in the following subparagraphs.
C-6.1.1 Third party witness: When ordered, the contractor shall act as a third party witness to observe operations and report findings to the DLA Energy point of contact with a detailed report within 24 hours. DLA Energy will provide written instructions specific to the operations and objectives in the task order. The following are examples of operations commonly preformed: Tank to tank transfers, off-loading vessels, barges, tank trucks, containers, loading vessels, barges, tank trucks, containers.
C-6.1.2 Sampling of petroleum products: When ordered, the contractor shall be capablity of performing sampling of pipelines, vessels, barges, tank trucks, storage tanks, or any containers that may hold fuel in accordance with API MPMS and/or ASTM D4057, when requested. The contractor shall supply all equipment and material needed to perform tasks.
C-6.1.3 Gauging of petroleum products: When ordered, the contractor shall be capable of performing gauging of vessels (to include bunkers), barges, tank trucks, storage tanks, or any containers that may hold fuel. The Contractor shall supply all equipment and material need to perform task.
C-6.1.4 Cargo Inspection of petroleum products: When ordered, the contractor shall oversee operations to include:
Gauging, Sampling, Atmospheric Measuring, Tank cleanliness, Lightering transfers, and complete certified detailed reports within 24 hours. The Contractor shall supply all equipment and material needed to perform tasks.
Note: The contractor will have the authority to stop any operations that are thought to be unsafe but must immediately contact the POC named on the Task Order to explain why.
C-7.0 Sample Shipment: The contractor shall, upon request, be responsible for shipping fuel samples from locations in C-1.0.1 to the laboratories in the chart below. Fuel samples shall be shipped within 48 hours of request and arrive to the below laboratory within five calendar days.
Naval Air Systems Command HAZMART Bldg. 2385 22680 Hammond Road Patuxent River, MD 20670
US ARMY TARDEC
Petroleum Laboratory Bldg. 5085 U Avenue, Bldg 85 New Cumberland, PA 17070-
Aerospace Fuels Laboratory AFPA/PTPLA 2430 C Street, Bldg 70, Area B Wright Patterson AFB OH 45433-
Naval Research Laboratory 4555 Overlook Avenue, SW Washington, DC 20375
Southwest Research Institute 6220 Culebra Rd San Antonio, TX 78238-5166
Air Force Research Laboratory AFRL 2977 Hobson Way
WPAFB, OH 45433
Page | 5
Attachment 1: Products Specifications shall dictate the testing required and the contractor shall develop a plan based on product specifications (A level testing) and MIL-STD-3004-1 (B-1, B-2, B-3, C test). MIL-STD_3004-1 describes products to be tested, types of testing required and additional information as required. All referenced material can be obtained at http://quicksearch.dla.mil/, https://assist.dla.mil/, or by contacting the CO, COR, or QAR.
Jet Fuels Aviation Turbine Fuel, Grade JET A (Specification: ASTM D1655 latest version) and JET A-1, NATO F-35 (DEF Stan 91-091 latest version) Aviation Turbine Fuel, Kerosene Types, Grade JP-8 NATO F-34 (Specification: MIL-DTL-83133, latest version) Aviation Turbine Fuel, Grade JP-5 NATO F-44 (Specification: MIL-DTL-5624, latest version) Aviation Turbine Fuel, Thermally Stable, Grade JPTS (Specification: MIL-DTL-25524 latest version)
Aviation, Gasoline, NATO F-18 ASTM D910. (latest version)
Diesel Fuels Diesel Fuel, Navy Distillate NATO F-76 (Specification: MIL-DTL-16884, latest versions) Diesel Fuel Oil, Grades: Ultra-low sulfur No.1 & No. 2, Low Sulfur No.1 & No. 2 (Specification: ASTM D975, latest version) Diesel Fuel Oil, Biodiesel blends B6-B20 (Specification: ASTM D7467 latest version)
Marine Residual Fuel Oil Grade (RME-180, RMG-380, MGO) (Specification: ISO 8217 latest version) Unleaded Fuels Fuel, Automotive Spark Ignition Engine Grades (Specification: ASTM D4814, latest version) Unleaded Gasohol, (Midgrade, Premium, Regular) Specification: ASTM D4814, (latest version) Fuel Ethanol (E85) for Automotive Spark-Ignition Engines (Specification ASTM D5798 latest version) Additives Fuel System Icing Inhibitor, High Flash (FSII) (Specification: MIL-DTL-85470 latest version) Corrosion Inhibitor (CI) (Specification: MIL-PRF-25017 latest version) Lube Oils Lubrication Oil, Steam Turbine and Gear (LTL) MIL Symbol 2190 (Specification: MIL-PRF-17331 latest version) Lubrication Oil, LO6, MIL Symbol 9250, Shipboard Internal Combustion, High Output Diesel (Specification:
MIL-PRF-6081 latest version) Fuel Oil Fuel Oil Reclaimed (FOR) (specification: MIL-PRF-24951 latest version) http://quicksearch.dla.mil/ https://assist.dla.mil/ Table Row(s) Deleted� Table Row
[Old]: "Unleaded Specification: ASTM D7547, latest" [New]: "(latest"
Page | 6
Attachment 2: Series Testing Requirements The list below provides tests by name and methods that shall be required to be performed on petroleum products at the contractor’s laboratory in accordance with product specifications MIL-STD-3004-1, specifications, and authorized test methods. The contractor must refer to paragraph C-2.4 for instructions on how to incorporate and indicate if they cannot perform authorized method or submit a formal exception request to the DLA Energy CO for acceptance. Tests shall be requested by series or individually by a DLA Energy representative as situation warrants.
1. A Series (Specification testing in accordance with Attachment 1 and MIL-STD-3004-1)
2. B-1 Series (MIL-STD-3004-1 list tests required in group)
3. B-2 Series (MIL-STD-3004-1 list tests required in group)
4. B-3Series (MIL-STD-3004-1 list tests required in group)
5. C Series (MIL-STD-3004-1 list tests required in group)
Individual Tests: Individual tests may be requested from any test included in the A, B or C series or from the tables below.
Note: Tests are grouped by physical or chemical property and do not imply equivalency. Verify that the test is appropriate to the product specification prior to analysis.
1. Secured Fuel Series Testing Requirements and Specification Limits JP-5 Jet A Jet A-17 JP-8 F-24
Min. Max. Min. Max. Min. Max. Min. Max. Min. Max.
Appearance 2
Gravity, API @ 60 °F D1298/D4052 36.0 48.0 37.0 51.0 37.0 51.0 37.0 51.0 37.0 51.0
Density at 15°C (kg/m3) 788 845 775 840 775 840 775 840 775 840 Weight: lb/USG Calculated 6.6 7.0 6.5 7.0 6.5 7.0 6.5 7.0 6.5 7.0 Distillation (°C) D863
10% Recovered 205 205 205 205 205 20% Recovered Report Report 50% Recovered Report Report Report Report Report 90% Recovered Report Report Report Report Report Final Boiling Point 300 300 300 300 300 Freezing point, °C D5972/D2386
-46
-40
-47
-47
-40
Flash point, °C D93/D56 60 38 38 38 38
Particulate Matter (mg/L) D2276, D5452, Appendix C of MIL- DTL- 83133
0.5
Conductivity (pS/m) D2624 Report Report 50 700 50 700 Copper strip corrosion D130 No.1 No.1 No.1 No.1 No.1 Water reaction D1094 1b
Existent gum (mg/100 mL) D381 7 7 7 7 7 FSII, (vol %) D5006 1 0.07 0.20 0.04 0.15 0.04 0.15 Thermal Stability D3241
Change in pressure drop, mm Hg 25 25 25 25 25 One of the tube deposit rating methods shall be run:
(1) Ellipsometer (ETR)6 (nm) or Interferometer (ITR) (nm)
(2) Heater tube deposit, Visual Tube Rating (VTR)
< 3
< 3 < 3 < 3 < 3
Fatty Acid Methyl Ester (FAME)5
Text [Old]: "fuel" [New]: "Fuel"
Text Replaced� Text [Old]: "for Aviation fuel."
[New]: "and Specification Limits"
Table Row(s) Inserted�
Text Inserted�
"Change in pressure drop, mm Hg"
Table Cell(s) Inserted� Table Cell
"25"
"25"
"25"
Image Deleted� Image
Text Deleted�
"2. Jet A & Jet A-1 (NATO F35) Series Testing Requirements for Specifications ASTM D1655 and Def Stan 91091"
Table Cell Attributes Changed� Table Cell Border changed.
Text Inserted� Text "25"
Table Cell Attributes Changed� Table Cell Border changed.
Text Inserted� Text "25"
Page | 7
2. Jet A & Jet A-1 (NATO F35) Series Testing Requirements for Specifications ASTM D1655 and Def Stan 91-
A Series Characteristics Def Stan
91-091
ASTM
D1655
B-1 Series
B-2 Series
B-3 Series
C-Series
Appearance X X X X X X Color (Visual) X X X X X X Density or API Gravity X X X X X X Particulate Matter X X X X X Particle Count X X Total Acidity X X X Aromatics X X Total Sulfur X X Mercaptan Sulfur X X Doctor Test X X Distillation X X X X X Viscosity X X Smoke Point X X Naphthalenes X X Specific Energy X X Hydrogen Content X Calculated Cetane Index X Copper Strip Corrosion X X X X X Freezing Point X X X X X Existent Gum X X X X X Flash Point X X X X X X Water Reaction Lead Content (if present) X X X X
FSII X X X X X
Filtration Time
MSEP X X X X X
Electrical Conductivity X X X X X Thermal Stability X X X X Color (Saybolt) X X X Peroxide Number X
FAME X X X X X
Lubricity X
X
Text "2. Jet A & Jet A-1 (NATO F35) Series Testing Requirements for Specifications ASTM D1655 and Def Stan 91091"
Table Cell Attributes Changed� Table Cell Border changed.
Table Cell(s) Deleted�
[Old]: "Appearance/Workmanship" [New]: "Appearance"
Font-size "11.04" changed to "10.02".
Text Attributes Changed� Text Font-size "11.04" changed to "10.02".
Text Inserted� Text "Density or API Gravity"
Text Inserted� Text "X"
Text Inserted� Text "X"
Text Inserted� Text "X"
Table Cell Attributes Changed� Table Cell Border changed.
Text Inserted� Text "X"
Text Inserted� Text "X"
Text Inserted� Text "X"
Text Attributes Changed� Text Font-size "11.04" changed to "10.02".
Text Deleted� Text "Contamination/Particulate"
Text Attributes Changed� Text Font-size "11.04" changed to "10.02".
Text Attributes Changed�
Font-size "11.04" changed to "10.02".
Text Deleted� Text "(Particulate)"
Text Inserted� Text "X"
Table Cell Attributes Changed� Table Cell Border changed.
Text Inserted� Text "X"
Table Cell Attributes Changed� Table Cell Border changed.
Text Deleted� Text "X"
Text Attributes Changed� Text Font-size "11.04" changed to "10.02".
Text Attributes Changed� Text Font-size "11.04" changed to "10.02".
Table Cell Attributes Changed� Table Cell Border changed.
Text Inserted� Text "X"
Table Cell Attributes Changed� Table Cell Border changed.
Text Deleted� Text "X"
Text Attributes Changed� Text Font-size "11.04" changed to "10.02".
Table Cell Attributes Changed� Table Cell Border changed.
Text Inserted� Text "X"
Table Cell Attributes Changed� Table Cell Border changed.
Text Deleted� Text "X"
Text Attributes Changed� Text Font-size "11.04" changed to "10.02".
Table Cell Attributes Changed� Table Cell Border changed.
Text Inserted� Text "X"
Table Cell Attributes Changed� Table Cell Border changed.
Text Deleted� Text "X"
Text Attributes Changed� Text Font-size "11.04" changed to "10.02".
Table Cell Attributes Changed� Table Cell Border changed.
Text Inserted� Text "X"
Table Cell Attributes Changed� Table Cell Border changed.
Text Deleted� Text "X"
Text Attributes Changed� Text Font-size "11.04" changed to "10.02".
Table Cell Attributes Changed� Table Cell Border changed.
Text Inserted� Text "Viscosity"
Text Inserted� Text "X"
Table Cell Attributes Changed�
Border changed.
Text Deleted� Text "API Gravity or Density at 15°C"
Table Cell Attributes Changed� Table Cell Border changed.
"X"
"X"
Table Cell Attributes Changed� Table Cell Border changed.
Text Deleted� Text "X"
Table Cell Attributes Changed� Table Cell Border changed.
Table Cell Attributes Changed� Table Cell Border changed.
Text Deleted� Text "Freezing Point"
Table Cell Attributes Changed� Table Cell Border changed.
Text Deleted� Text "X"
"X"
Table Cell Attributes Changed� Table Cell Border changed.
Text Deleted� Text "X"
Table Cell Attributes Changed� Table Cell Border changed.
Table Cell Attributes Changed� Table Cell Border changed.
Text Deleted� Text "Viscosity at minus 20°C"
Table Cell Attributes Changed� Table Cell Border changed.
Text Deleted� Text "X"
Table Cell Attributes Changed� Table Cell Border changed.
Text Inserted� Text "Specific Energy"
Table Cell Attributes Changed� Table Cell Border changed.
Text Inserted� Text "X"
Border changed.
Text Deleted� Text "X"
Table Cell Attributes Changed� Table Cell Border changed.
Text Inserted� Text "Hydrogen Content"
Table Cell Attributes Changed� Table Cell Border changed.
Table Cell Attributes Changed� Table Cell Border changed.
Border changed.
Text Deleted� Text "X"
Table Cell Attributes Changed� Table Cell Border changed.
Text Inserted� Text "Calculated Cetane Index"
Table Cell Attributes Changed� Table Cell Border changed.
Table Cell Attributes Changed� Table Cell Border changed.
Table Cell Attributes Changed� Table Cell Border changed.
[Old]: "Specific Energy (Net Heat of Combustion)" [New]: "Copper Strip Corrosion"
Font-size "11.04" changed to "10.02".
Text Inserted� Text "X"
Table Cell Attributes Changed� Table Cell Border changed.
Text Inserted� Text "X"
Text Inserted� Text "X"
Table Cell Attributes Changed� Table Cell Border changed.
Table Cell Attributes Changed� Table Cell Border changed.
Text Inserted� Text "Freezing Point"
Font-size "11.04" changed to "10.02".
Border changed.
Text Inserted� Text "Lead Content (if present)"
Text Replaced� Text [Old]: "Microseparometer" [New]: "X"
Font "TimesNewRomanPS-BoldMT" changed to "TimesNewRomanPSMT".
Table Cell Attributes Changed� Table Cell Border changed.
Text Deleted� Text "X"
Text Deleted� Text "X"
Table Cell Attributes Changed� Table Cell Border changed.
Text Inserted� Text
"FSII"
Text Replaced� Text [Old]: "Electrical Conductivity" [New]: "X"
Font "TimesNewRomanPS-BoldMT" changed to "TimesNewRomanPSMT".
Table Cell Attributes Changed� Table Cell Border changed.
Table Cell Attributes Changed� Table Cell Border changed.
Text Replaced� Text [Old]: "X" [New]: "Filtration Time"
Font "TimesNewRomanPSMT" changed to "TimesNewRomanPS-BoldMT".
Font-size "11.04" changed to "10.02".
Border changed.
Text Deleted� Text "Lubricity"
Table Cell Attributes Changed� Table Cell Border changed.
Table Cell Attributes Changed� Table Cell Border changed.
Text Inserted� Text
"MSEP"
Table Cell Attributes Changed� Table Cell Border changed.
Text Inserted� Text "X"
Border changed.
Text Inserted� Text "X"
"X"
Table Cell Attributes Changed� Table Cell Border changed.
Text Inserted� Text "Electrical Conductivity"
Table Cell Attributes Changed� Table Cell Border changed.
Text Inserted� Text "X"
Table Cell Attributes Changed� Table Cell Border changed.
Text Replaced� Text [Old]: "Particulate Contamination/Particulate Matter with Filtration Time" [New]: "X"
Font "TimesNewRomanPS-BoldMT" changed to "TimesNewRomanPSMT".
Table Cell Attributes Changed� Table Cell Border changed.
"Color (Saybolt)"
Table Cell Attributes Changed� Table Cell Border changed.
Border changed.
Text Replaced� Text [Old]: "Fuel System Icing Inhibitor" [New]: "Peroxide Number"
Font-size "11.04" changed to "9.52609".
Text Deleted� Text "X"
Text Deleted� Text "X"
Text Deleted� Text "X"
Text Deleted� Text "X"
Table Cell Attributes Changed� Table Cell Border changed.
Text Attributes Changed� Text Font-size "11.04" changed to "10.02".
Border changed.
Text Inserted� Text "Lubricity"
Border changed.
Text Replaced� Text [Old]: "Sulfides in Bottom Water" [New]: "X"
Font "TimesNewRomanPS-BoldMT" changed to "TimesNewRomanPSMT".
Table Cell Attributes Changed� Table Cell Border changed.
Text Inserted� Text "X"
Page | 8
3. JP8 (NATO F34) Series Testing Requirements for Specifications MIL-DTL-83133
Characteristics MIL DTL
83133 B-1
Series B-2
B-3 Series C-Series
Appearance/Workmanship X X X X X Color (Visual) X X X X X Particulate Contamination/Particulate Matter
X X X X
Particle Count X Total Acidity X X Aromatics X Total Sulfur X Mercaptan Sulfur X Doctor Test X Distillation X X X X Flash Point X X X X X API Gravity or Density at 15°C X X X X X Freezing Point X X X X Viscosity at minus 20°C X Specific Energy (Net Heat of Combustion)
X
Copper Strip X X X X Thermal Stability X X X Existent Gum X X X X Microseparometer X X X X Electrical Conductivity X X X X Lubricity Colour, Saybolt X X Particulate Contamination/Particulate Matter with Filtration Time
X X X X
Fuel System Icing Inhibitor X X X X
FAME X X X X
Hydrogen Content X Cetane Index, Calculated X Water Reaction Sulfides in Bottom Water
Text Replaced� Text [Old]: "MIL DTL 83133" [New]: "MIL-DTL-83133"
Table Cell Attributes Changed� Table Cell Border changed.
Table Cell Attributes Changed�
Border changed.
Page | 9
4. JP5 (NATO F44) Series Testing Requirements for Specifications MIL-DTL-5624
B-1
B-2 Series B-3 Series C- Series
Particulate Contamination/ Particulate Matter
X X X X
Particle Count X Total Acidity X X Aromatics X Total Sulfur X Mercaptan Sulfur X Doctor Test X Distillation X X X X Flash Point X X X X X API or Density at 15° C X X X X X Vapor Pressure X Freezing Point X X X X Viscosity at minus 20°C X Smoke Point X Naphthalenes X Specific Energy (Net Heat of Combustion)
X
Copper Strip X X X X Thermal Stability X X X Existent Gum X X X X Microseparometer X Electrical Conductivity X Colour, Saybolt X X Particulate Contamination/Particulate Matter with Filtration Time
X X X X
Fuel System Icing Inhibitor X X X X
FAME X X X X
Hydrogen Content X Cetane Index, Calculated X Water Reaction Sulfides in Bottom Water
Text Replaced� Text [Old]: "MIL DTL 5624" [New]: "MIL-DTL-5624"
Table Cell Attributes Changed� Table Cell Border changed.
Table Cell Attributes Changed� Table Cell Border changed.
Table Cell Attributes Changed� Table Cell Border changed.
Table Cell Attributes Changed� Table Cell Border changed.
Table Cell Attributes Changed� Table Cell Border changed.
Table Cell Attributes Changed� Table Cell Border changed.
Table Cell Attributes Changed� Table Cell Border changed.
Table Cell Attributes Changed� Table Cell Border changed.
Table Cell Attributes Changed� Table Cell Border changed.
Table Cell Attributes Changed� Table Cell Border changed.
Table Cell Attributes Changed� Table Cell Border changed.
Table Cell Attributes Changed�
Page | 10
5. JPTS Series Testing Requirements for Specifications MIL-DTL-25524
Characteristics MIL DTL 25524 B-1
B-2 Series B-3 Series
Color, Saybolt X X Total Acid Number X X Aromatics X Mercaptan Sulfur X Doctor Test X Total Sulfur X Distillation X X X X Flash point X X X X Density X X X X Freezing point X X X X Viscosity @ -40°C X Net heat of combustion X Hydrogen content X Smoke point X Copper Strip Corrosion X X X X Thermal Stability X X X Existent Gum X X X X Particulate Matter X X X X Particle Counting X Micro-Separometer X
FSII X X X X
Appearance X X X X Visual Color X X X X Filtration time X X X
FAME X X X
Text Inserted� Text "JPTS Series Testing Requirements for Specifications MIL-DTL-25524"
"Characteristics"
Text Inserted� Text
"MIL DTL 25524"
Text Inserted� Text "B-1 Series"
Text Inserted� Text "B-2 Series"
Text Inserted� Text "B-3 Series"
"Color, Saybolt"
Text Inserted� Text "X"
"X"
"Total Acid Number"
Text Inserted� Text "X"
"X"
"X"
"X"
"X"
"X"
"Distillation"
Text Inserted� Text "X"
Text Inserted� Text "X"
Text Inserted� Text "X"
Text Inserted� Text "X"
"Net heat of combustion"
"X"
"Hydrogen content"
"X"
"Smoke point"
"X"
"Copper Strip Corrosion"
Text Inserted� Text "X"
Text Inserted� Text "X"
Text Inserted� Text "X"
Text Inserted� Text "X"
"X"
Text Inserted� Text "X"
Text Inserted� Text "X"
"Existent Gum"
Text Inserted� Text "X"
Text Inserted� Text "X"
Text Inserted� Text "X"
Text Inserted� Text "X"
"Micro-Separometer"
"X"
"X"
Text Inserted� Text "X"
Text Inserted� Text "X"
Text Inserted� Text "X"
"Page | 10"
Text Inserted�
"Page | 10"
Page | 11
6. Avgas Series Testing Requirements for Specifications ASTM 910.
Characteristics ASTM 910 B-1
Series B-2
B-3 Series
Appearance/Workmanship X X X X Net heat of combustion X Lean Mixture Motor Octane Number
(MON)
X
Aviation Lean Rating X Performance number X Sulfur Content X Tetraethyl Lead X Dye content (Blue Dye) X Vapor Pressure X X X Density at 15°C X X X X Distillation X X X X Freezing Point X Copper Strip X X X X Oxidation Stability X Water Reaction X Conductivity X Color, Visual X X X Existent Gum X X Specific Energy Colour, Lovibond Particulate Matter X X X Free Water Determination X X X Lead Content X X Potential Gum X
Text Inserted� Text "6. Avgas Series Testing Requirements for Specifications ASTM 910."
"Characteristics"
Text Inserted� Text
"ASTM 910"
Text Inserted� Text "B-1 Series"
Text Inserted� Text "B-2 Series"
Text Inserted� Text "B-3 Series"
"Appearance/Workmanship"
Text Inserted� Text "X"
Text Inserted� Text "X"
Text Inserted� Text "X"
Text Inserted� Text "X"
"Lean Mixture Motor Octane Number (MON)"
"X"
"Aviation Lean Rating"
"X"
"Performance number"
"X"
"Sulfur Content"
"X"
"Tetraethyl Lead"
"X"
"Dye content (Blue Dye)"
"X"
"Vapor Pressure"
Text Inserted� Text "X"
Text Inserted� Text "X"
Text Inserted� Text "X"
"Density at 15°C"
Text Inserted� Text "X"
Text Inserted� Text "X"
Text Inserted� Text "X"
Text Inserted� Text "X"
"X"
"Copper Strip"
Text Inserted� Text "X"
Text Inserted� Text "X"
Text Inserted� Text "X"
Text Inserted� Text "X"
"Water Reaction"
"X"
"Conductivity"
"X"
"Color, Visual"
"X"
Text Inserted� Text "X"
Text Inserted� Text "X"
"Colour, Lovibond"
"Particulate Matter"
"X"
Text Inserted� Text "X"
Text Inserted� Text "X"
"Potential Gum"
"X"
"Page | 11"
Text Inserted�
"Page | 11"
Page | 12
7. F-76 Series Testing Requirements for Specification MIL-DTL-16884
Characteristics MIL F
16884 B-1
Series B-2
Demulsification X API Gravity or Density at 15°C X X X X X Distillation X X X Cloud Point X X Color X X X X X Flashpoint X X X X X Particulate Contamination X X X Pour Point X X Viscosity at 40°C X X Acid Number X Ash X Aromatics X Carbon Residue X X X Copper Strip Corrosion X X Hydrogen Content X Ignition Quality (Cetane Number, Cetane Index, or Derived…
This is the start of the file's text. The full file is on GovTribe.