Att 1 - REVISED Price Schedule 100324.xlsx

XLSX spreadsheet 100 KB Posted

Attached to
North Florida Regional HW Removal Federal contract opportunity
Solicitation number
SP450024R0021
Issued by
Defense Logistics Agency

About this file

This document is a price schedule for a federal contract opportunity for North Florida Regional HW Removal, solicitation number SP450024R0021. The contract is for the removal, transportation, and disposal of government-generated hazardous and non-hazardous wastes located on military installations in and around North Florida. The contract has a 30-month base period from February 2025 to August 2027 and a 30-month option period.

The price schedule includes various CLINs for the rental of rolloff boxes, vacuum boxes, and FRAC tanks, as well as sampling and analysis services, spill response supplies, industrial cleaning services, and management services. Offerors must submit their bids by October 24, 2024. The contract will be awarded on a full and open competitive basis with a NAICS code of 562211 and a small business size standard of $47M.

View the file

Other files for this federal contract opportunity

Other files attached to North Florida Regional HW Removal, newest first.
File Type Posted
SF 30 Amendment 0005.doc DOC document
Att 1 - NFL PS REVISED 112124.xlsx XLSX spreadsheet
Att 2 NFL PWS REVISED 112124.docx DOCX document
SF 30 Amendment 0004.doc DOC document
SF 30 Amendment 0003.doc DOC document
SF 30 Amendment 0002.doc DOC document
20D09 Order History 0823to0824.xlsx XLSX spreadsheet
SF 30 Amendment 0001.doc DOC document
Att 2 - REVISED Performance Work Statement 100324.docx DOCX document
Att 6 - Additional Contract Terms and Conditions.docx DOCX document
Att 5 - Dept of Labor Wage Determination.pdf PDF
Att 11 - ROB or Vac Box Checklist.pdf PDF
Att 3 - Pick up Points).xlsx XLSX spreadsheet
Att 12 - DLA Form 2505 Invoice.xlsx XLSX spreadsheet
Att 8 - Addenda to 52.212‐1 Instructions.docx DOCX document
Att 9 - Addenda to 52.212‐2 Evaluation.docx DOCX document
Att 4 - PPI Questionnaire.pdf PDF
Att 10 - ICS-KTR Work Surveillance Checklist.pdf PDF
Att 7 - CAC Application Process.pdf PDF
Att 2 - Performance Work Statement.docx DOCX document
Att 1 - Price Schedule.xlsx XLSX spreadsheet
Show all 21

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Base North Florida HW Disposal - 30 Month Base

CLIN Description CLIN Est. Qty. U/I Price Extended Cost

1020REDaily Rental of a 20-yd3 Lined Rolloff Box (ROB) With Cover (See 3.2).1020RE25EA$ - 0
1021REWeekly Rental of a 20-yd3 Lined Rolloff Box (ROB) With Cover (See 3.3).1021RE5EA$ - 0
1022REMonthly Rental of a 20-yd3 Lined Rolloff Box (ROB) With Cover (See 3.4).1022RE5EA$ - 0
1023REAnnual Rental of a 20-yd3 Lined Rolloff Box (ROB) With Cover (See 3.5).1023RE3EA$ - 0
1040REDaily Rental of a 40-yd3 Lined Rolloff Box (ROB) With Cover (See 3.2).1040RE25EA$ - 0
1041REWeekly Rental of a 40-yd3 Lined Rolloff Box (ROB) With Cover (See 3.3).1041RE5EA$ - 0
1042REMonthly Rental of a 40-yd3 Lined Rolloff Box (ROB) With Cover (See 3.4).1042RE5EA$ - 0
1043REAnnual Rental of a 40-yd3 Lined Rolloff Box (ROB) With Cover (See 3.5).1043RE3EA$ - 0
1060REDaily Rental of a 20- or 25-yd3 Vacuum Box (See 3.6).1060RE2EA$ - 0
1061REWeekly Rental of a 20- or 25-yd3 Vacuum Box (See 3.7).1061RE2EA$ - 0
1071REWeekly Rental of a FRAC Tank with Containment (See 3.8).1071RE10EA$ - 0
1072REMonthly Rental of a FRAC Tank with Containment (See 3.9).1072RE5EA$ - 0
1200REInitial Placement or Removal of Empty Rented Rolloff Box or Vacuum Box (See 3.10).1200RE33EA$ - 0
1000SAPerform sampling and analysis to determine Waste Characteristics (D001-D0043) using current SW-846 Methods. Provide Hazardous Waste Profile Sheet (HWPS).1000SA10EA$ - 0
1001SAPerform sampling and analysis to determine Waste Characteristics (D001-D0043) and UHCs using current SW-846 Methods. Provide Hazardous Waste Profile Sheet (HWPS). (See 3.26)1001SA5EA$ - 0
1002SAPerform sampling and analysis to determine waste characteristics for Ignitability (D001), Corrosivity (D002), and Reactivity (D003) using current EPA approved methods.
Five (5) business day deliverables required.1002SA1EA$ - 0
1003SAPerform sampling and analysis to determine TCLP concentrations of toxic Metals and Organic Compounds corresponding to EPA Waste Codes D004-D043 and UHCs, using current SW-846 Methods.1003SA2EA$ - 0
1030SAPerform sampling and analysis to determine Toxicity Characteristics of eight (8) RCRA Metals (D004-D011) and four (4) UHC Metals via TCLP, SW-846 Method 1311 and current SW-846 quantitative detection method(s).1030SA5EA$ - 0
1370SAPerform analysis to identify contents of a compressed gas cylinder and complete a Waste Profile Sheet.1370SA1EA$ - 0
1900SATest for PFAS in Drinking Water, EPA Method 537.1 or updates thereto.1900SA5EA$ - 0
1904SAProvide sampling and analysis for Per- and Polyfluoroalkyl Substances (PFAS) using Liquid Chromatography Tandem Mass Spectrometry (LC/MS/MS) with Isotope Dilution or Internal Standard Quantification in matrices other than drinking water. Sample bottles must be provided by the laboratory. Only accredited laboratories per current DoD QSM may be used.1904SA5EA$ - 0
1905SAPerform sampling and analysis of non-drinking Water and Solids for forty (40) Per- and Polyfluoroalkyl Substances (PFAS) using EPA Method 1633 or updates thereto. Sample bottles must be provided by the laboratory. Only a DoD ELAP accredited laboratory shall be used, but it need not be accredited specifically for EPA Method 1633.1905SA10EA$ - 0
1010SPLoose absorbent media, Universal, 40 lb bag.1010SP150EA$ - 0
1011SPLoose absorbent media, Oil based liquids, 5 lb bag.1011SP20EA$ - 0
1020SPAbsorbent mat pad, Universal, dispenser box, indoor use, 100 ct.1020SP30EA$ - 0
1021SPAbsorbent mat pad, Oil only, dispenser box, indoor use, 100 ct.1021SP30EA$ - 0
1026SPGloves, NITRILE, 6 mil, medium 1EA=1BOX.1026SP12EA$ - 0
1027SPGloves, NITRILE, 6 mil, large, 1EA=1BOX.1027SP12EA$ - 0
1028SPGloves, NITRILE, 6 mil, Xlarge, 1EA=1BOX.1028SP35EA$ - 0
1029SPGloves, NITRILE, 6 mil, XXlarge, 1EA=1BOX.1029SP65EA$ - 0
1152SP5 GL, poly DR, new, OPN, pail w/screw top built in turning handle, DUAL UN 1H2/Y1.5/30 AND 1H2/Y30/S.1152SP3,000EA$ - 0
1153SP5 GL, poly DR, new, OPN, pail w/screw top built in turning handle, DUAL UN 1H2/Y1.5/30 AND 1H2/Y30/S, 1EA=25.1153SP200EA$ - 0
1155SP5 GL, poly DR, new, OPN, pail w/screw top lid with spout UN 1H2/Y1.5/30.1155SP3,000EA$ - 0
1330SP30 GL, poly DR, new, OPN, lever lock ring, lid, UN 1H2/Y180/S.1330SP60EA$ - 0
1332SP30 GL, poly DR, new, OPN, open head w/ring and lid, UN 1H2/Y180/S. 1 EA = 10 containers.1332SP60EA$ - 0
1342SP30 GL, metal DR, new, Removeable head, with bung, UN 1A2/Y1.4/100.1342SP1,000EA$ - 0
1402SP55 GL, poly DR, new, OPN, UN 1H2/Y, open top, new.1402SP60EA$ - 0
1472SP55 GL, metal DR, recon, removeable head with bung, UN 1A2/Y1.5/150.1472SP1,500EA$ - 0
1473SP55 GL, metal DR, recon, removeable head with bung, UN 1A2/Y1.5/150, 1EA=25.1473SP90EA$ - 0
1500SP85 GL, metal DR, new, OPN, EP lined, bolt ring, UN1A2/X435/S or UN1A2T/Y320/S.1500SP50EA$ - 0
1503SP85 GL, poly DR, new, OPN, UN1H2/Y130/S1503SP50EA$ - 0
1623SPBOX, 36"x36"x36", cardboard, with top and liner, UN 11G/X/.1623SP1,000EA$ - 0
1641SP275 GL, tote, poly, new, with pallet, UN 31HA1/Y.1641SP500EA$ - 0
1642SP275 GL, tote, poly, new, with pallet, UN 31HA1/Y, 1EA=5.1642SP50EA$ - 0
1654SP4 Ft fiber fluorescent bulb box (capacity 85 bulbs), UN 1G/Y50/S.1654SP125EA$ - 0
1668SP8 Ft fiber fluorescent bulb box (capacity 70 bulbs), UN 1G/Y50/S.1668SP30EA$ - 0
6377AX50 GAL plastic drum liner 6 MIL (1 EA = 1 roll of 90 liners).6377AX250EA$ - 0
6312K4Provide 1.8-cubic-yard bags, i.e., super sacks, fabric, w/ straps and built-in liners UN 3H1/1.8/250.6312K450EA$ - 0
6377AJ2 GAL UN1H2/Y12.2/S Plastic pail with screw on lids.6377AJ200EA$ - 0
6377AP1 Cubic Yard UN13H4/X Poly bags with liners.6377AP60EA$ - 0
6377AQ55 GAL UN13H4/Y Poly bags with liners.6377AQ60EA$ - 0
1002SVIndustrial Cleaning Services, Daily, Crew of Two (2) (See 3.11).1002SV10EA$ - 0
1003SVIndustrial Cleaning Services, Weekly, Crew of Two (2) (See 3.12).1003SV2EA$ - 0
1007SVIndustrial Cleaning Services, Daily, Crew of Three (3) (See 3.14).1007SV5EA$ - 0
1008SVIndustrial Cleaning Services, Weekly, Crew of Three (3) (See 3.15).1008SV5EA$ - 0
1080SVSurcharge for Weekend Work, Daily, Crew of Two (2) (See 3.17).1080SV2EA$ - 0
1081SVSurcharge for Weekend Work, Daily, Crew of Three (3) (See 3.18).1081SV2EA$ - 0
1082SVSurcharge for Hydro/Water Blasting Work, Daily, Crew of Three (3) (See 3.19).1082SV2EA$ - 0
1083SVSurcharge for Permit-Required Confined Space Work, Daily, Crew of Three (3) (See 3.20).1083SV2EA$ - 0
1084SVSurcharge for Super Vacuum Truck Work, Daily, Crew of Three (3). (See 3.21).1084SV2EA$ - 0
1095SV1-Business Day Expedited Removal/Performance (See 1.2.11).1095SV1EA$ - 0
1096SV3-Business Day Expedited Removal/Performance (See 1.2.11).1096SV45EA$ - 0
1097SV5-Business Day Expedited Removal/Performance (See 1.2.11).1097SV41EA$ - 0
1099SVSurcharge for Expedited Commencement of ICS Work, Crew of Two-Three (2-3) (See 3.22).1099SV2EA$ - 0
1100SVMove empty ROB, Vacuum Box, of FRAC tank within installation (3.10.1).1100SV10EA$ - 0
1202SVOverpack/Loose Pack smaller container(s) into one Government-provided container up to 5-gal pail (See 3.27).1202SV5EA$ - 0
1203SVOverpack/Loose Pack smaller container(s) into one Government-provided container up to 15-gal drum (See 3.27).1203SV8EA$ - 0
1204SVOverpack/Loose Pack smaller container(s) into one Government-provided container up to 30-gal drum (See 3.27).1204SV3EA$ - 0
1205SVOverpack/Loose Pack smaller container(s) into one Government-provided container up to 55-gal drum (See 3.27).1205SV5EA$ - 0
1206SVOverpack smaller container(s) into one Government-provided container up to 110-gal drum (See 3.27).1206SV3EA$ - 0
1207SVLoose Pack smaller container(s) into one Government-provided CYB or Tri-Wall Box (See 3.27).1207SV5EA$ - 0
1208SVPrepare/Provide Lab Pack of chemicals into one Contractor-provided container up to 5-gal pail (See 3.28).1208SV5EA$ - 0
1209SVPrepare/Provide Lab Pack of chemicals into one Contractor-provided container up to 15-gal drum (See 3.28).1209SV5EA$ - 0
1210SVPrepare/Provide Lab Pack of chemicals into one Contractor-provided container up to 30-gal drum (See 3.28).1210SV5EA$ - 0
1211SVPrepare/Provide Lab Pack of chemicals into one Contractor-provided container up to 55-gal drum (See 3.28).1211SV110EA$ - 0
1212SVPrepare/Provide Lab Pack of chemicals into one Contractor-provided container up to CYB or Tri-Wall Box (See 3.28).1212SV5EA$ - 0
6335FFExpedited removal - Retrograde Shipments (See 1.2.11.1)6335FF4EA$ - 0
6360AAManagement services to move containers not on TO. One each equals labor for one person for one hour (See 1.2.6.d).6360AA303EA$ - 0
6360GTManagement services - includes but is not limited to packaging, labeling, profiling, manifesting and assisting the loading of HM/HW. One each equals labor for one person for 8 hours (See 3.31).6360GT5EA$ - 0
6387VTVacuum Truck with Dump Function and Operator. One (1) each = One (1) 8-hr workday (See 3.30.5).6387VT5EA$ - 0
6387SVSuper Vacuum Truck and Operator. One (1) each = One (1) 8-hr. workday (See 3.30.6).6387SV5EA$ - 0
6391AHMarine Vessel Bilge Pumping additional air hose required, One (1) EA = One (1) 25-foot length of air hose (See 3.30.3).6391AH90EA$ - 0
6391BPMarine Vessel Bilge Pumping. 1 EA includes but not strictly limited to a vaccum/tanker collection vehicle/trailer one (1) operator, two (2) technicians and minimum of 400 feet of vacuum or pumping hose up to four (4) hours (See 3.30).6391BP12EA$ - 0
6391ETMarine Vessel Bilge Pumping extra time needed to complete work, One (1) EA = One (1)HR (See 3.30).6391ET3,500EA$ - 0
6391LHMarine Vessel Bilge Pumping additional vaccum or pump hoses required. One (1) EA = One (1) 50-foot length of vacuum or pump hose (See 3.30.2).6391LH2,200EA$ - 0
6391PPMarine Vessel Bilge Pumping, Contractor will provide double diaphragm/sandpiper pump, (see 3.30.4).6391PP70EA$ - 0
6391TSMarine Vessel Bilge Pumping additional technician required. One (1)EA = four (4) hours of work (See 3.30.1).6391TS500EA$ - 0
6400AAPrepare Waste Profile Sheet/Form (See 3.25).6400AA25EA$ - 0
6503Provide certificate of disposal (See 2.1).650315EA$ - 0
6502VXManagement Services - Provide vapor/gas free certification (See 3.33).6502VX10EA$ - 0
6609GTManagement Services - Travel to and from Guantananmo Bay, Cuba (See 3.31).6609GT2EA$ - 0
6610PASurcharge for Zone "A" Poison Gases (See 2.5.4).6610PA1EA$ - 0
6611GTMaterials to perform required services in Guantananmo Bay, Cuba, not to exceed $25,000 per performance period. (See 3.31).6611GTN/AEA
6631Stabilization of MEKP and/or Peroxides (See 3.32).66311EA$ - 0
BA01Alkaline Batteries, for Contractor's choice of recycling or disposal.

Physical State: Various

Permissible EPA Waste Codes: UW, D002, D004-11.BA01C749,000LB$ - 0
BA02Calcium Chromate (CaCrO4) Thermal Batteries, Intact & Deactivated, for Contractor's choice of recycling or disposal.

Physical State: Solid

Permissible EPA Waste Codes: UW, D001 (OX), D002-11.BA02C725LB$ - 0
BA03Carbon-Zinc (CZn) Batteries, for Contractor's choice of recycling or disposal.

Physical State: Solid

Permissible EPA Waste Codes: UW, D002, D004-11.BA03C7100LB$ - 0
BA04Lead Acid Batteries, Wet, Dry, or Gel Pack. May be managed as UW, HW, or RCRA Exempt under 40 CFR Part 266, Subpart G. For mandatory recycling/recovery.

Physical State: Various

Permissible EPA Waste Codes: UW, D002, D004-11.BA04C747,000LB$ - 0
BA05Lithium Ion (Li-Ion) Batteries, for mandatory recycling.

Physical State: Solid

Permissible EPA Waste Codes: UW, D001-11.BA05C77,500LB$ - 0
BA06Lithium Iron Disulfide (Li2FeS2) Thermal Batteries, including fully discharged Lithium Alloy Thermal Batteries, for Contractor's choice of recycling or disposal.

Physical State: Solid

Permissible EPA Waste Codes: UW, D002-11.BA06C7400LB$ - 0
BA07Lithium Manganese (LiMn and Oxides thereof) Batteries, for Contractor's choice of recycling or disposal.

Physical State: Solid

Permissible EPA Waste Codes: UW, D002-11.BA07C7390LB$ - 0
BA08Lithium Sulfur Dioxide (LiSO2) Batteries, for Contractor's choice of recycling or disposal.

Physical State: Solid

Permissible EPA Waste Codes: UW, D002-11.BA08C79,230LB$ - 0
BA09Lithium Thionyl Chloride (LiSCl) Batteries, for Contractor's choice of recycling or disposal.

Physical State: Solid

Permissible EPA Waste Codes: UW, D002-11.BA09C736LB$ - 0
BA10Lithium Batteries, Mixed Types, deactivated if applicable, for Contractor's choice of recycling or disposal.

Physical State: Solid

Permissible EPA Waste Codes: UW, D001-11.BA10C722,856LB$ - 0
BA12Mercury (Hg) Batteries, for mandatory recycling.

Physical State: Solid

Permissible EPA Waste Codes: UW, D002, D004-11.BA12C7238LB$ - 0
BA13Nickel Metal Hydride (NiMh) Batteries, Wet and Dry, for mandatory recycling.

Physical State: Various

Permissible EPA Waste Codes: UW, D002, D004-11.BA13C72,634LB$ - 0
BA14Nickel-Cadmium (NiCd) Batteries, Wet and Dry, for mandatory recycling.

Physical State: Various

Permissible EPA Waste Codes: UW, D002, D004-11.BA14C77,867LB$ - 0
BA15Silver-Zinc (AgZn) and Zinc Silver Oxide (ZnAgO) Batteries for mandatory recycling.

Physical State: Solid

Permissible EPA Waste Codes: UW, D002, D004-11.BA15C721LB$ - 0
CS01Corrosive Acids, Inorganic other than HF and HNO3, <50% in Water, Non-Fuming, <1% Total Metals, Cr+6 <100 ppm.

Physical State: Liquid

Permissible EPA Waste Codes: D002, D004-11, Listed Inorganics.CS01C175EA$ - 0
CS01C35EA$ - 0
CS01C420EA$ - 0
CS01C52EA$ - 0
CS01B515,000GL$ - 0
CS01T2125EA$ - 0
CS02Corrosive Acids, Inorganic other than HF and HNO3, <50% in Water, Non-Fuming, >1% Total Metals, Cr+6 <100 ppm.

Physical State: Liquid

Permissible EPA Waste Codes: D002, D004-11, Listed Inorganics.CS02C123EA$ - 0
CS02C2139EA$ - 0
CS02C35EA$ - 0
CS02C44EA$ - 0
CS03Corrosive Acids, Inorganic other than HF and HNO3, Concentrated, <1% Total Metals, Cr+6 <100 ppm.

Physical State: Liquid

Permissible EPA Waste Codes: D002, D004-11, Listed Inorganics.CS03C12EA$ - 0
CS03B52,000GL$ - 0
CS04Corrosive Acids, Chromic (H2CrO4), <1% Cr+6, Characteristic Liquids, Solids, Sludges, Debris.

Physical State: Various

Permissible EPA Waste Codes: D001 (OX), D002, D004-11.CS04C110EA$ - 0
CS05Corrosive Acids, Chromic (H2CrO4), 1-10% Cr+6, Characteristic Liquids, Solids, Sludges, Debris.

Physical State: Various

Permissible EPA Waste Codes: D001 (OX), D002, D004-11.CS05C1107EA$ - 0
CS05C41EA$ - 0
CS07Corrosive Acids, Chromic (H2CrO4), >100 ppm Cr+6, Listed Liquids, Solids, Sludges, Debris.

Physical State: Various

Permissible EPA Waste Codes: D001 (OX), D002, D004-11, F-Listed, U032.CS07B51,700GL$ - 0
CS08Corrosive Acids, Non-Fuming, Hydrofluoric (HF) <40% and/or Nitric (HNO3), <25% in Water.

Physical State: Liquid

Permissible EPA Waste Codes: D001 (OX), D002, D004-11, Listed Inorganics.CS08C183EA$ - 0
CS08C22EA$ - 0
CS08C412EA$ - 0
CS08B55,100GL$ - 0
CS08T2125EA$ - 0
CS09Corrosive Acids, Fuming, Hydrofluoric (HF) >40% and/or Nitric (HNO3), ≥25% in Water.

Physical State: Liquid

Permissible EPA Waste Codes: D001 (OX), D002, D004-11, Listed Inorganics.CS09C112EA$ - 0
CS10Corrosive Alkalines, Inorganic, <50% in Water, <1% Total Metals, Cr+6 <100 ppm, No Ammonia/Amines.

Physical State: Liquid

Permissible EPA Waste Codes: D002, D004-11, Listed Inorganics.CS10C173EA$ - 0
CS10C21EA$ - 0
CS10C32EA$ - 0
CS10C496EA$ - 0
CS10B540,000GL$ - 0
CS10T2125EA$ - 0
CS11Corrosive Alkalines, Inorganic, <50% in Water, >1% Total Metals, Cr+6 <100 ppm, No Ammonia/Amines.

Physical State: Liquid

Permissible EPA Waste Codes: D002, D004-11, Listed Inorganics.CS11C116EA$ - 0
CS12Corrosive Ammonia/Amines, Organic/Inorganic, Liquids/Sludges/Solids/Debris, Flashpoint ≥140◦F.

Physical State: Various

Permissible EPA Waste Codes: D002, D004-43, Listed.CS12C149EA$ - 0
CS12C21EA$ - 0
CS12C33EA$ - 0
CS12C45EA$ - 0
CS12B51,200GL$ - 0
CS13Corrosive Organic Acids or Bases, Liquids/Sludges/Solids/Debris, No Ammonia/Amines, Flashpoint ≥140◦F.

Physical State: Various

Permissible EPA Waste Codes: D002, D004-43, Listed.CS13C115EA$ - 0
CS13C41EA$ - 0
CS14Corrosive Inorganic Acids or Bases with Debris and Free Liquids, No Ammonia/Amines, Non-Flammable, including broken lead acid batteries.

Physical State: Various

Permissible EPA Waste Codes: D002, D004-11, Listed.CS14C135EA$ - 0
CS14C210EA$ - 0
CS14C34EA$ - 0
CS14C44EA$ - 0
CY01Category 1 Compressed Gas Cylinders (CGC), Cartridges, Canisters and Vessels. Refer to CGC Cross-Reference Table for list of gases.

Physical State: Comp. Gas

Permissible EPA Waste Codes: As applicable to contained gas or mixed gases.CY01ME718EA$ - 0
CY01M1515EA$ - 0
CY01M215EA$ - 0
CY01M318EA$ - 0
CY02Category 2 Compressed Gas Cylinders (CGC), Cartridges, Canisters and Vessels. Refer to CGC Cross-Reference Table for list of gases.

Physical State: Comp. Gas

Permissible EPA Waste Codes: As applicable to contained gas or mixed gases.CY02ME557EA$ - 0
CY02M130EA$ - 0
CY02M24EA$ - 0
CY02M316EA$ - 0
CY03Category 3 Compressed Gas Cylinders (CGC), Cartridges, Canisters and Vessels. Refer to CGC Cross-Reference Table for list of gases.

Physical State: Comp. Gas

Permissible EPA Waste Codes: As applicable to contained gas or mixed gases.CY03ME13EA$ - 0
CY05Category 5 Compressed Gas Cylinders (CGC), Cartridges, Canisters and Vessels. Refer to CGC Cross-Reference Table for list of gases.

Physical State: Comp. Gas

Permissible EPA Waste Codes: As applicable to contained gas or mixed gases.CY05ME13EA$ - 0
CY06Category 6 Compressed Gas Cylinders (CGC), Cartridges, Canisters and Vessels. Refer to CGC Cross-Reference Table for list of gases.

Physical State: Comp. Gas

Permissible EPA Waste Codes: As applicable to contained gas or mixed gases.CY06ME4EA$ - 0
CY08Category 8 Compressed Gas Cylinders (CGC), Cartridges, Canisters and Vessels. Refer to CGC Cross-Reference Table for list of gases.

Physical State: Comp. Gas

Permissible EPA Waste Codes: As applicable to contained gas or mixed gases.CY08M33EA$ - 0
CY10Cylinders, Acetylene, No Asbestos, for Recycle/Reuse.

Physical State: Comp. Gas

Permissible EPA Waste Codes: D001.CY10M24EA$ - 0
CY12Cylinders, Flammable, AVGAS, Ether Gas/Diesel Starting, for Disposal or Recycle. Diameter up to 3", Length up to 12". "ME" = 1 EA Cylinder. Physical State: Comp. Gas
Permissible EPA Waste Codes: D001.CY12ME4EA$ - 0
CY13Cartridges, Inert Gas, for Disposal/Recycle/Reuse. Diameter up to 1", Length up to 6". "ME" = 1 EA Cartridge.

Physical State: Comp. Gas

Permissible EPA Waste Codes: N/A.CY13ME1,916EA$ - 0
FL01Aerosols, Flammable/Combustible/Ignitable, non-foaming. No isocyanates, reactives, or corrosives, even when managed as UW.

Physical State: Various

Permissible EPA Waste Codes: UW, D001 (IGN), D004-43, Listed.FL01C739,636LB$ - 0
FL02Flammable Debris contaminated with common solvents, shreddable, no free liquids, no large metal, rock, or masonry components.

Physical State: Solid

Permissible EPA Waste Codes: D001, D004-43, Listed.FL02C11EA$ - 0
FL02C43EA$ - 0
FL02C62EA$ - 0
FL03Flammable Liquids/Solids/Sludges/Debris, e.g., tank sludge, lubricants, adhesives, miscellaneous debris. Primarily consists of incinerable, non-fuels-blendable materials. No isocyanates (See FL16). Use LP03 for loose packs.

Physical State: Various

Permissible EPA Waste Codes: D001 (IGN), D002, D004-43, Listed.FL03C1295EA$ - 0
FL03C26EA$ - 0
FL03C399EA$ - 0
FL03C4397EA$ - 0
FL03C57EA$ - 0
FL03C610EA$ - 0
FL03T2125EA$ - 0
FL04Flammable Corrosive Liquids/Solids/Sludges/Debris/Aerosols. Use LP03 for loose packs other than aerosols. FL04C7 for use with flammable corrosive aerosols only.

Physical State: Various

Permissible EPA Waste Codes: UW (Aerosols Only), D001 (IGN), D002, D004-43, Listed.FL04C1176EA$ - 0
FL04C236EA$ - 0
FL04C382EA$ - 0
FL04C445EA$ - 0
FL04C51EA$ - 0
FL05Flammable Liquids, Pumpable, Fuels Blendable, Rich, >7,000 BTU/Lb, <5% total chlorine, no isocyanates.

Physical State: Liquid

Permissible EPA Waste Codes: D001 (IGN), D004-43, Listed.FL05C11,200EA$ - 0
FL05C27EA$ - 0
FL05C3424EA$ - 0
FL05C4971EA$ - 0
FL05C510EA$ - 0
FL05C66EA$ - 0
FL05T2125EA$ - 0
FL05B5128,568GL$ - 0
FL06Flammable Liquids, Pumpable, Fuels Blendable, Lean, 2,500-7,000 BTU/Lb, <5% total chlorine, no isocyanates.

Physical State: Liquid

Permissible EPA Waste Codes: D001 (IGN), D004-43, Listed.FL06B513,125GL$ - 0
FL07Flammable Liquids, Pumpable, Fuels Blendable, Lean to Rich, >2,500 BTU/Lb, 5-10% total chlorine, no isocyanates.

Physical State: Liquid

Permissible EPA Waste Codes: D001 (IGN), D004-43, Listed.FL07C134EA$ - 0
FL07C33EA$ - 0
FL07C42EA$ - 0
FL09Flammable Resuspendable Solids/Sludges, Fuels Blendable, Lean, 2,500-7,000 BTU/Lb, <5% total chlorine, no isocyanates.

Physical State: Various

Permissible EPA Waste Codes: D001 (IGN), D004-43, Listed.FL09C11EA$ - 0
FL09C317EA$ - 0
FL09C41EA$ - 0
FL11Flammable Liquids, Highly Chlorinated (>10%), Pumpable, Solvents, Herbicides, and Pesticides. No PCBs, Dioxins, Furans, or Precursors.

Physical State: Liquid

Permissible EPA Waste Codes: UW (Pesticides Only), D001 (IGN), D004-43, Listed.FL11C31EA$ - 0
FL13Oxidizers, Non-Reactive, Liquids/Sludges/Solids/Debris, other than chromic acid (see Corrosives).

Physical State: Various

Permissible EPA Waste Codes: D001 (OX), D002, D004-43, Listed.FL13C13EA$ - 0
FL13C32EA$ - 0
FL13C426EA$ - 0
FL15Water Contaminated with Common Solvents, pumpable if bulk, <2,500 BTU/Lb.

Physical State: Liquid

Permissible EPA Waste Codes: D001 (IGN), D004-43, Listed.FL15C21EA$ - 0
FL15C423EA$ - 0
FL16Non-Reactive paints and other coatings listing isocyanates in the ingredients. Use LP16 for loose packs.

Physical State: Various

Permissible EPA Waste Codes: D001 (IGN), D004-43, Listed.FL16C110EA$ - 0
FL16C210EA$ - 0
FL16C310EA$ - 0
FL16C440EA$ - 0
FL16C52EA$ - 0
FL16C610EA$ - 0
FL99Military Items, Demil-required, Flammable Solids/Liquids/Debris, e.g., NBC/CDE Kits, Vials, Filters, PPE, etc. for conventional RCRA treatment, disposal. CD required.

Physical State: Various

Permissible EPA Waste Codes: D001 (IGN), D002, D004-43, Listed.FL99C7105LB$ - 0
LP01Lab Packs/Loose Packs, Corrosives, Organic or Inorganic, Liquids or Solids, Non-Flammable.

Physical State: Various

Permissible EPA Waste Codes: D002, D004-11, Listed.LP01C1160EA$ - 0
LP01C26EA$ - 0
LP01C334EA$ - 0
LP01C432EA$ - 0
LP01C51EA$ - 0
LP01C610EA$ - 0
LP02Lab Packs/Loose Packs, Mercury, Elemental Liquid, for mandatory recycling in U.S.

Physical State: Various

Permissible EPA Waste Codes: D004-11, Listed Inorganics.LP02C22EA$ - 0
LP03Lap Packs/Loose Packs, Flammables and Flammable Corrosives, other than paints and paint-related materials eligible for LP14, for mandatory RCRA incineration. No isocyanates (See LP16).

Physical State: Various

Permissible EPA Waste Codes: D001 (IGN), D002, D004-43, Listed.LP03C1535EA$ - 0
LP03C223EA$ - 0
LP03C3253EA$ - 0
LP03C4564EA$ - 0
LP03C616EA$ - 0
LP04Lab Packs/Loose Packs, Non-RCRA, State and Non-State Regulated, other than paints eligible for LP15, includes pharmaceuticals.

Physical State: Various

Permissible EPA Waste Codes: N/A.LP04C1728EA$ - 0
LP04C244EA$ - 0
LP04C3449EA$ - 0
LP04C4818EA$ - 0
LP04C52EA$ - 0
LP04C623EA$ - 0
LP05Lab Packs/Loose Packs, Non-Reactive Oxidizers.

Physical State: Various

Permissible EPA Waste Codes: D001 (OX), D002, D004-43, Listed.LP05C169EA$ - 0
LP05C315EA$ - 0
LP05C44EA$ - 0
LP06Lab Packs/Loose Packs, Reactive Oxidizers, including Organic Peroxides, for mandatory RCRA incineration. Generator special packaging may be required.

Physical State: Various

Permissible EPA Waste Codes: D001 (OX), D002-43, Listed.LP06C16EA$ - 0
LP06C33EA$ - 0
LP07Lab Packs/Loose Packs, Reactive Metals, Wet/Dry, includes Broken Sodium Lamps, MRE heaters, E-cigarettes and associated components and residues. Generator special packaging may be required.

Physical State: Various

Permissible EPA Waste Codes: D001-43, Listed.LP07C13EA$ - 0
LP07C31EA$ - 0
LP08Lab Packs/Loose Packs, Reactives, Non-Metals, Non-Oxidizing, for mandatory RCRA incineration. Generator special packaging may be required.

Physical State: Various

Permissible EPA Waste Codes: D001-43, Listed.LP08C11EA$ - 0
LP09Lab Packs/Loose Packs, Toxic Metals.

Physical State: Various

Permissible EPA Waste Codes: D004-11, Listed Inorganics.LP09C158EA$ - 0
LP09C36EA$ - 0
LP10Lab Packs/Loose Packs, Toxic Organics.

Physical State: Various

Permissible EPA Waste Codes: D004-43, Listed.LP10C124EA$ - 0
LP10C312EA$ - 0
LP10C44EA$ - 0
LP11Lab Packs/Loose Packs, Toxic, Acutely Hazardous, P-Listed, for mandatory RCRA incineration. Includes pharmaceuticals. May be packaged with U-Listed waste. Special Generator turn-in requirements may apply.

Physical State: Various

Permissible EPA Waste Codes: D004-43, P-Listed, U-Listed.LP11C193EA$ - 0
LP11C22EA$ - 0
LP11C311EA$ - 0
LP12Lab Packs/Loose Packs, Toxic, U-Listed, including pharmaceuticals, for mandatory RCRA incineration. Special Generator turn-in requirements may apply.

Physical State: Various

Permissible EPA Waste Codes: D004-43, U-Listed.LP12C124EA$ - 0
LP12C22EA$ - 0
LP12C32EA$ - 0
LP12C49EA$ - 0
LP14Loose-Packed Paints and Paint-Related Materials, Primarily Oil/Petroleum-Based, >7,000 BTU/Lb. May contain <50% water-based paints. Formerly CLIN FL14. No Isocyanates (see LP16).

Physical State: Various

Permissible EPA Waste Codes: D001 (IGN), D004-43, Listed.LP14C1683EA$ - 0
LP14C27EA$ - 0
LP14C3210EA$ - 0
LP14C4971EA$ - 0
LP14C611EA$ - 0
LP15Loose-Packed Paints and Paint-Related Materials, Water-Based/Latex, Non-RCRA, for solidification and disposal at a RCRA Subtitle D landfill, or equivalent. Formerly CLIN NR06. Physical State: Various Permissible EPA Waste Codes: N/A.LP15C134EA$ - 0
LP15C24EA$ - 0
LP15C337EA$ - 0
LP15C4136EA$ - 0
LP15C612EA$ - 0
LP16Loose-Packed Paints. Non-Reactive paints and other coatings listing isocyanates in the ingredients.

Physical State: Various

Permissible EPA Waste Codes: D001 (IGN), D004-43, Listed.LP16C125EA$ - 0
LP16C215EA$ - 0
LP16C315EA$ - 0
LP16C440EA$ - 0
LP16C52EA$ - 0
LP16C66EA$ - 0
LP78Lab Packs/Loose Packs, Non-RCRA, State and Non-State Regulated, including pharmaceuticals, for mandatory RCRA Incineration. Special Generator turn-in requirements may apply. CD required.

Physical State: Various

Permissible EPA Waste Codes: N/A.LP78C174EA$ - 0
LP78C21EA$ - 0
LP78C311EA$ - 0
LP78C488EA$ - 0
NR01Non-Regulated Solids/Debris, for direct landfill disposal. Passes paint filter test. No asbestos. May include toner, toner cartridges, drained/dry non-PCB transformers, ballasts, capacitors, and related equipment.

Physical State: Solid

Permissible EPA Waste Codes: N/A.NR01C1506EA$ - 0
NR01C221EA$ - 0
NR01C3400EA$ - 0
NR01C42,769EA$ - 0
NR01C51EA$ - 0
NR01C6262EA$ - 0
NR01B653CD$ - 0
NR02Non-RCRA Solids/Debris with Asbestos, for direct disposal at a TSCA/RCRA Subtitle D landfill, or equivalent. Passes paint filter test. Special packaging may be required.

Physical State: Solid

Permissible EPA Waste Codes: N/A.NR02C111EA$ - 0
NR02C315EA$ - 0
NR02C419EA$ - 0
NR02C69EA$ - 0
NR02B655CD$ - 0
NR03Non-RCRA Liquids, Water-Based, pumpable. NR03B5 must meet acceptance criteria for wastewater treatment (WWT) and discharge to POTW, per Section 3.29.

Physical State: Liquid

Permissible EPA Waste Codes: N/A.NR03C190EA$ - 0
NR03C23EA$ - 0
NR03C341EA$ - 0
NR03C4325EA$ - 0
NR03C51EA$ - 0
NR03C64EA$ - 0
NR03T2125EA$ - 0
NR03B575,000GL$ - 0
NR04Non-RCRA Liquids, Organic-Based, pumpable, primarily consisting of wastes containing hydrocarbons.

Physical State: Liquid

Permissible EPA Waste Codes: N/A.NR04C1251EA$ - 0
NR04C366EA$ - 0
NR04C4209EA$ - 0
NR04C54EA$ - 0
NR04C61EA$ - 0
NR04T250EA$ - 0
NR04B520,000GL$ - 0
NR05Non-RCRA Liquids/Sludges/Solids/Debris, requiring solidification prior to disposal at a RCRA Subtitle D landfill, or equivalent. Includes bulk liquids not meeting acceptance criteria for wastewater treatment (WWT). May include non-PCB oil-filled transformers, ballasts, capacitors and related equipment. See 3.29.

Physical State: Various

Permissible EPA Waste Codes: N/A.NR05C1297EA$ - 0
NR05C28EA$ - 0
NR05C3102EA$ - 0
NR05C41,314EA$ - 0
NR05C518EA$ - 0
NR05C614EA$ - 0
NR05T2125EA$ - 0
NR05B520,000GL$ - 0
NR09Non-RCRA Empty Containers Meeting EPA "RCRA-Empty" Definition, Metal and/or Plastic/Poly, crushed or damaged, for Contractor's choice of Recycle or Disposal. (See 2.2)

Physical State: Solid

Permissible EPA Waste Codes: N/A.NR09C119EA$ - 0
PC01PCB wastes containing or contaminated with a ≥50 ppm PCB Source (≥5 ppm in CA), RCRA or Non-RCRA, e.g., fluids, soil, sludge, debris, leaking capacitors. CD required.

Physical State: Various

Permissible EPA Waste Codes: D001-43, Listed.PC01C850KG$ - 0
PC03PCB Mineral Oil from Transformers, 50-4,000 ppm PCBs (5-4,000 ppm in CA). Non-RCRA, CD or Cert of Recycling required.

Physical State: Liquid

Permissible EPA Waste Codes: N/A.PC03C8900KG$ - 0
PC06PCB Oil-Filled Capacitors/Ballasts/Equipment other than Transformers, ≥50 ppm PCBs (≥5 ppm in CA), Non-RCRA, CD or Cert of Recycling required.

Physical State: Various

Permissible EPA Waste Codes: N/A.PC06C8200KG$ - 0
PC09PCB Solids/Debris Contaminated with <50 ppm Source (<5 ppm in CA), e.g., soil, transformer carcasses, drained equipment, ballasts, rags, PPE, empty containers. No Free Liquids. Non-RCRA.

Physical State: Solid

Permissible EPA Waste Codes: N/A.PC09C8700KG$ - 0
PC10PCB Solids/Debris Contaminated with ≥50 ppm Source (≥5 ppm in CA), e.g., soil, transformer carcasses, drained equipment, ballasts, rags, PPE, empty containers. No Free Liquids. Non-RCRA. CD or Cert of Recycling required.

Physical State: Solid

Permissible EPA Waste Codes: N/A.PC10C8100KG$ - 0
PC11PCB and Non-PCB Related ballasts and other devices containing <50 ppm (<5 ppm in CA) for Mandatory Recycling of recyclable components. Cert of Recycling required.

Physical State: Various

Permissible EPA Waste Codes: N/A.PC11C8700KG$ - 0
PC12PCB Related ballasts and other devices containing ≥50 ppm (≥5 ppm in CA) for Mandatory Recycling of recyclable components. Cert of Recycling required.

Physical State: Various

Permissible EPA Waste Codes: N/A.PC12C850KG$ - 0
PF03AFFF and other PFAS-related Liquids/Waters, Non-RCRA, >100 ppm PFAS, for treatment and disposal at RCRA Subtitle C Landfill specifically designated as authorized for PFAS disposal in the QFL. . <10% suspended solids, pumpable if bulk. Includes AFFF Rinsates & Concentrates. Certificate of Disposal required. See 2.4.

Physical State: Liquid

Permissible EPA Waste Codes: N/A.PF03C11,190EA$ - 0
PF03C331EA$ - 0
PF03C4244EA$ - 0
PF03T217EA$ - 0
PF06AFFF and other PFAS-related Solids/Debris, Non-RCRA, >100 ppm PFAS, for direct disposal at RCRA Subtitle C Landfill specifically designated as authorized for PFAS disposal in the QFL. Passes Paint Filter Test. No Cylinders. Certificate of Disposal required. See 2.4.

Physical State: Solid

Permissible EPA Waste Codes: N/A.PF06C15EA$ - 0
PF06C25EA$ - 0
PF06C35EA$ - 0
PF06C432EA$ - 0
PF06C65EA$ - 0
PF06B618CD$ - 0
PF41AFFF Fire Extinguishers, handheld, containing pressurized liquid with varying PFAS formulations. Non-RCRA. Requires disposal of all liquid components at a RCRA Subtitle C landfill specifically designated as authorized for PFAS disposal in the QFL. CD required. Certificate of Disposal required. See 2.4. CLIN Suffix liquid capacities:

M1 = Up to 1 liter, up to approximately 4"D x 10"L (Small) M2 = Up to 3 liters, up to approximately 5"D x 16"L (Med)

M3 = >3 liters, generally greater than 5"D x 16"L (Large) Physical State: Liquid Permissible EPA Waste Codes: N/A.PF41M346EA$ - 0
RE01Lamps, Fluorescent, Intact. Includes CFLs, U-Bent, Circulars.

Physical State: Solid

Permissible EPA Waste Codes: UW, D004-11.RE01C781,467LB$ - 0
RE02Lamps, Fluorescent, Crushed/Broken, may contain filters.

Physical State: Solid

Permissible EPA Waste Codes: UW, D004-11.RE02C1131EA$ - 0
RE02C313EA$ - 0
RE02C449EA$ - 0
RE02C61EA$ - 0
RE03Lamps, Halogen.

Physical State: Solid

Permissible EPA Waste Codes: UW, D004-11.RE03C7500LB$ - 0
RE04Lamps, High Intensity Discharge (HID) and/or Light Emitting Diode (LED).

Physical State: Solid

Permissible EPA Waste Codes: UW, D004-11.RE04C71,292LB$ - 0
RE05Lamps, Mercury/Mercury Vapor.

Physical State: Solid

Permissible EPA Waste Codes: UW, D004-11.RE05C73,254LB$ - 0
RE06Lamps, Metal Halide and Metal Hydride, including Sodium.

Physical State: Solid

Permissible EPA Waste Codes: UW, D003-11.RE06C72,741LB$ - 0
RE07Mercury, High, COD Vials, Nessler's Reagent, Chemicals and Residues, Hg >260 mg/Kg.

Physical State: Various

Permissible EPA Waste Codes: UW, D002, D004-11.RE07C18EA$ - 0
RE07C49EA$ - 0
RE08Mercury, High, Dental Amalgams, Debris & Residues, Hg >260 mg/Kg. See 3.34.

Physical State: Various

Permissible EPA Waste Codes: UW, D004-11.RE08C193EA$ - 0
RE08C31EA$ - 0
RE08C43EA$ - 0
RE09Mercury, High, Liquid Mercury/Devices, Debris & Residues, Hg >260 mg/Kg.

Physical State: Various

Permissible EPA Waste Codes: UW, D004-11.RE09C125EA$ - 0
RE09C31EA$ - 0
RE09C47EA$ - 0
RE10Antifreeze, used and unused, for energy recovery (recycling, fuels blending). Note: RE10ME refers to 55-gal drums (Min. 30 EA/Task Order) bulked onsite, removed, leaving empty drums with Generator.

Physical State: Liquid

Permissible EPA Waste Codes: UW, D004-11.RE10C146EA$ - 0
RE10C318EA$ - 0
RE10C459EA$ - 0
RE10C53EA$ - 0
RE10B51,676GL$ - 0
RE11Used Oil, <10% Water, <1,000 ppm total organic halides (TOX), for energy recovery (recycling, fuels blending). Note: RE11ME refers to 55-gal drums (Min. 30 EA/Task Order) bulked onsite, removed, leaving empty drums with Generator.

Physical State: Liquid

Permissible EPA Waste Codes: UW, D004-11 .RE11C13EA$ - 0
RE11C21EA$ - 0
RE11C37EA$ - 0
RE11C413EA$ - 0
RE11C53EA$ - 0
RE11B586,646GL$ - 0
RE11ME843EA$ - 0
RE12Used Oil, >10% Water, <1,000 ppm total organic halides (TOX) for energy recovery (recycling, fuels blending). Note: RE12ME refers to 55-gal drums (Min. 30 EA/Task Order) bulked onsite, removed, leaving empty drums with Generator.

Physical State: Liquid

Permissible EPA Waste Codes: UW, D004-11.RE12C47EA$ - 0
RE13Used Oil Filters, Drained and Undrained, and/or Fully Drained Fuel Filters.

Physical State: Various

Permissible EPA Waste Codes: UW, D004-11.RE13C1129EA$ - 0
RE13C23EA$ - 0
RE13C3107EA$ - 0
RE13C4685EA$ - 0
RE13C53EA$ - 0
RE14Lead Articles and Spent Ammunitions Meeting Specs for Recovery.

Physical State: Solid

Permissible EPA Waste Codes: UW, D004-11.RE14C32EA$ - 0
RX01Aerosols, Foaming, Isocyanates or other reactives.

Physical State: Various

Permissible EPA Waste Codes: UW, D001-43, Listed.RX01C75,192LB$ - 0
RX02Cyanide, >50% Debris, >590 mg/Kg Total CN.

Physical State: Various

Permissible EPA Waste Codes: D002-11, Listed.RX02C41EA$ - 0
RX04Cyanide Liquids, Solids, <50% Debris, 1%-10% Total CN.

Physical State: Various

Permissible EPA Waste Codes: D002-11, Listed.RX04C16EA$ - 0
RX05Cyanide Liquids, Solids, <50% Debris, >10% Total CN.

Physical State: Various

Permissible EPA Waste Codes: D002-11, Listed.RX05C46EA$ - 0
RX06Reactive Oxidizers, e.g., Nitrates, Nitrites, Persulfates, Inorganic Peroxides, No Organic Peroxides.

Physical State: Various

Permissible EPA Waste Codes: D001-11, Listed.RX06C145EA$ - 0
RX06C21EA$ - 0
RX06C32EA$ - 0
RX06C44EA$ - 0
RX07Polymerizing Materials, e.g, Styrene, Isocyanates, Acrylates, etc.

Physical State: Various

Permissible EPA Waste Codes: D001-11, Listed.RX07C110EA$ - 0
RX08Reactive Metals, e.g., powders, dusts, fines. Air/Water Reactive. Shipped under oil and/or other Generator special packaging may be required.

Physical State: Solid

Permissible EPA Waste Codes: D001, D003, D004-11, Listed.RX08C14EA$ - 0
RX09Reactive Metals, Debris. Air/Water Reactive. Shipped under oil and/or other Generator special packaging may be required.

Physical State: Solid

Permissible EPA Waste Codes: D001, D003, D004-11, Listed.RX09C11EA$ - 0
RX97Reactive, Ignitable, and Toxic Liquid for RCRA Incineration. Contains Water, Mineral Spirits, Motor Oil, <1% Cyanide, <1% Alcohol, <1% Total RCRA Metals.

Physical State: Liquid

Permissible EPA Waste Codes: D001-11, Listed.RX97C12EA$ - 0
RX97C41EA$ - 0
RX98OBA Canisters, EEBDs and Oxygen Candles, Potentially Reactive, Spent and/or Unspent. Special packaging may be required.

Physical State: Solid

Permissible EPA Waste Codes: D001, D003, D004-11.RX98C15EA$ - 0
RX98C423EA$ - 0
RX99Military Items, Demil-Required, Reactive, Solids/Liquids/Debris, e.g., CDE Kits, Vials, Filters, PPE, etc. (No Batteries) for Conventional RCRA Treatment and Disposal. Must Carry D003. CD required.

Physical State: Various

Permissible EPA Waste Codes: D001-D043, Listed.RX99C423EA$ - 0
TX01Chromium, Hexavalent, <1% Cr+6, Characteristic Liquids, Solids, Sludges.

Physical State: Various

Permissible EPA Waste Codes: D001 (OX), D004-11.TX01C11EA$ - 0
TX02Chromium, Hexavalent, 1-10% Cr+6, Characteristic Liquids, Solids, Sludges.

Physical State: Various

Permissible EPA Waste Codes: D001 (OX), D004-11.TX02C122EA$ - 0
TX02C21EA$ - 0
TX02C419EA$ - 0
TX02C641EA$ - 0
TX04Chromium, Hexavalent, <1% Cr+6, Listed Liquids, Solids, Sludges.

Physical State: Various

Permissible EPA Waste Codes: D004-11, F006-12, F019.TX04C121EA$ - 0
TX04C44EA$ - 0
TX05Chromium, Hexavalent, Wastewater, Pumpable, <1% Total Metals.

Physical State: Liquid

Permissible EPA Waste Codes: D004-11, Listed Inorganics.TX05C11EA$ - 0
TX05C31EA$ - 0
TX05C478EA$ - 0
TX06Debris, Inorganic Constituents Only. >50% debris by volume, >60 mm (~2.5") particle size. No free liquids unless incidental rainwater or condensation (see TX20). Refer to Section 1.2.8.1.e.

Physical State: Debris

Permissible EPA Waste Codes: D004-11, Listed Inorganics.TX06C1331EA$ - 0
TX06C27EA$ - 0
TX06C3307EA$ - 0
TX06C4926EA$ - 0
TX06C51EA$ - 0
TX06C6326EA$ - 0
TX06B6521CD$ - 0
TX07Debris, Organic Constituents. >50% Debris by volume, >60 mm (~2.5") particle size. Total VOCs <500 ppm. No free liquids unless incidental rainwater or condensation (see TX20). May include inorganic Waste Code(s) and/or RCRA hazardous asbestos. Refer to Section 1.2.8.e.

Physical State: Debris

Permissible EPA Waste Codes: D004-43, Listed, but no F020-32.TX07C11,046EA$ - 0
TX07C212EA$ - 0
TX07C31,579EA$ - 0
TX07C49,170EA$ - 0
TX07C62,613EA$ - 0
TX07B6734CD$ - 0
TX09High Halogen Liquids/Sludges/Solids/Debris, Non-Flammable, Includes Solvents, Herbicides and Pesticides.

Physical State: Various

Permissible EPA Waste Codes: UW, D004-43, Listed.TX09C12EA$ - 0
TX09C49EA$ - 0
TX10Metals in Wastewater, <5% Suspended Solids, <1% Total Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm.

Physical State: Liquid

Permissible EPA Waste Codes: D004-11, Listed Inorganics.TX10C16EA$ - 0
TX10C21EA$ - 0
TX10C31EA$ - 0
TX10C42EA$ - 0
TX11Metals in Wastewater, <5% Suspended Solids, >1% Total Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm.

Physical State: Liquid

Permissible EPA Waste Codes: D004-11, Listed Inorganics.TX11B51,700GL$ - 0
TX12Metals-Bearing Liquids, Low, <1% TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, pumpable if bulk. Characteristic only.

Physical State: Liquid

Permissible EPA Waste Codes: D004-11.TX12C1310EA$ - 0
TX12C21EA$ - 0
TX12C399EA$ - 0
TX12C4325EA$ - 0
TX12C54EA$ - 0
TX12T2125EA$ - 0
TX12B569,375GL$ - 0
TX13Metals-Bearing Liquids, Low, <1% TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, pumpable if bulk. Listed, or Listed + Characteristic.

Physical State: Liquid

Permissible EPA Waste Codes: D004-11, Listed Inorganics.TX13C119EA$ - 0
TX13C33EA$ - 0
TX13C496EA$ - 0
TX13T2125EA$ - 0
TX13B515,000GL$ - 0
TX15Metals-Bearing Liquids, High, >1% TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, pumpable if bulk. Listed, or Listed + Characteristic.

Physical State: Liquid

Permissible EPA Waste Codes: D004-11, Listed Inorganics.TX15C13EA$ - 0
TX15C22EA$ - 0
TX15C41EA$ - 0
TX16Metals-Bearing Solids/Sludges/Some Free Liquids, Low (<1%) TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm. Characteristic only.

Physical State: Various

Permissible EPA Waste Codes: D004-11.TX16C1170EA$ - 0
TX16C21EA$ - 0
TX16C3328EA$ - 0
TX16C42,490EA$ - 0
TX16C57EA$ - 0
TX16C6103EA$ - 0
TX16B120,000LB$ - 0
TX16B222,000LB$ - 0
TX16B331,000LB$ - 0
TX16B441,000LB$ - 0
TX16B641CD$ - 0
TX17Metals-Bearing Solids/Sludges/Some Free Liquids, Low (<1%) TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm. Listed, or Listed + Characteristic.

Physical State: Various

Permissible EPA Waste Codes: D004-11, Listed Inorganics.TX17C61EA$ - 0
TX21Organics Contaminated Water, Pumpable, <10% Suspended Solids, <10% Organics, e.g., Toluene, Phenol in water. Not more toxic than common solvents.

Physical State: Liquid

Permissible EPA Waste Codes: D004-43, Listed.TX21C123EA$ - 0
TX21C21EA$ - 0
TX21C318EA$ - 0
TX21C4607EA$ - 0
TX21C54EA$ - 0
TX21B54,863GL$ - 0
TX22Organics in Solids/Sludges/Debris, i.e. soil, tank & still bottoms, adhesives, filtercake. Not more toxic than common solvents.

Physical State: Various

Permissible EPA Waste Codes: D004-43, Listed.TX22C141EA$ - 0
TX22C4109EA$ - 0
TX22C51EA$ - 0
TX22C62EA$ - 0
TX22B196,547LB$ - 0
TX22B280,000LB$ - 0
TX24Organic Solvents, Technical Grade, pure or mixed solutions, with or without water and/or metals, pumpable if bulk, Flashpoint ≥140°F.

Physical State: Liquid

Permissible EPA Waste Codes: D004-43, Listed.TX24C11EA$ - 0
TX96Special Hull Treatment (SHT) Tiles, Demil-required via macroencapsulation and RCRA Subtitle C landfill disposal. Direct shipment to TSDF in locked and tamper sealed steel-topped rolloff box required. CD and verification of intact tamper seal upon arrival at TSDF required. For use even when no EPA Waste Codes apply. See Section 2.7.1.

Physical State: Solid

Permissible EPA Waste Codes: D004-11.TX96B120,000LB$ - 0
TX96B220,000LB$ - 0
TX96B330,000LB$ - 0
TX96B440,000LB$ - 0
TX97Toxic Electron Tubes, intact, Demil-required. CD required.

Physical State: Solid

Permissible EPA Waste Codes: D004-11.TX97C11EA$ - 0
TX97C31EA$ - 0
TX99Military Submarine Tiles, Demil-required via RCRA Incineration. For use even when no EPA Waste Codes apply. Requires direct shipment to TSDF. CD required. See Section 2.7.1.

Physical State: Solid

Permissible EPA Waste Codes: D004-11.TX99C75,000LB$ - 0
TX99B110,000LB$ - 0
TX99B220,000LB$ - 0
TX99B330,000LB$ - 0
TX99B6250CD$ - 0
Total$ - 0

Option North Florida HW Disposal - 30 Month Option

CLIN Description CLIN Est. Qty. U/I Price Extended Cost

1020REDaily Rental of a 20-yd3 Lined Rolloff Box (ROB) With Cover (See 3.2).1020RE25EA$ - 0
1021REWeekly Rental of a 20-yd3 Lined Rolloff Box (ROB) With Cover (See 3.3).1021RE5EA$ - 0
1022REMonthly Rental of a 20-yd3 Lined Rolloff Box (ROB) With Cover (See 3.4).1022RE5EA$ - 0
1023REAnnual Rental of a 20-yd3 Lined Rolloff Box (ROB) With Cover (See 3.5).1023RE3EA$ - 0
1040REDaily Rental of a 40-yd3 Lined Rolloff Box (ROB) With Cover (See 3.2).1040RE25EA$ - 0
1041REWeekly Rental of a 40-yd3 Lined Rolloff Box (ROB) With Cover (See 3.3).1041RE5EA$ - 0
1042REMonthly Rental of a 40-yd3 Lined Rolloff Box (ROB) With Cover (See 3.4).1042RE5EA$ - 0
1043REAnnual Rental of a 40-yd3 Lined Rolloff Box (ROB) With Cover (See 3.5).1043RE3EA$ - 0
1060REDaily Rental of a 20- or 25-yd3 Vacuum Box (See 3.6).1060RE2EA$ - 0
1061REWeekly Rental of a 20- or 25-yd3 Vacuum Box (See 3.7).1061RE2EA$ - 0
1071REWeekly Rental of a FRAC Tank with Containment (See 3.8).1071RE10EA$ - 0
1072REMonthly Rental of a FRAC Tank with Containment (See 3.9).1072RE5EA$ - 0
1200REInitial Placement or Removal of Empty Rented Rolloff Box or Vacuum Box (See 3.10).1200RE33EA$ - 0
1000SAPerform sampling and analysis to determine Waste Characteristics (D001-D0043) using current SW-846 Methods. Provide Hazardous Waste Profile Sheet (HWPS).1000SA10EA$ - 0
1001SAPerform sampling and analysis to determine Waste Characteristics (D001-D0043) and UHCs using current SW-846 Methods. Provide Hazardous Waste Profile Sheet (HWPS). (See 3.26)1001SA5EA$ - 0
1002SAPerform sampling and analysis to determine waste characteristics for Ignitability (D001), Corrosivity (D002), and Reactivity (D003) using current EPA approved methods.
Five (5) business day deliverables required.1002SA1EA$ - 0
1003SAPerform sampling and analysis to determine TCLP concentrations of toxic Metals and Organic Compounds corresponding to EPA Waste Codes D004-D043 and UHCs, using current SW-846 Methods.1003SA2EA$ - 0
1030SAPerform sampling and analysis to determine Toxicity Characteristics of eight (8) RCRA Metals (D004-D011) and four (4) UHC Metals via TCLP, SW-846 Method 1311 and current SW-846 quantitative detection method(s).1030SA5EA$ - 0
1370SAPerform analysis to identify contents of a compressed gas cylinder and complete a Waste Profile Sheet.1370SA1EA$ - 0
1900SATest for PFAS in Drinking Water, EPA Method 537.1 or updates thereto.1900SA5EA$ - 0
1904SAProvide sampling and analysis for Per- and Polyfluoroalkyl Substances (PFAS) using Liquid Chromatography Tandem Mass Spectrometry (LC/MS/MS) with Isotope Dilution or Internal Standard Quantification in matrices other than drinking water. Sample bottles must be provided by the laboratory. Only accredited laboratories per current DoD QSM may be used.1904SA5EA$ - 0
1905SAPerform sampling and analysis of non-drinking Water and Solids for forty (40) Per- and Polyfluoroalkyl Substances (PFAS) using EPA Method 1633 or updates thereto. Sample bottles must be provided by the laboratory. Only a DoD ELAP accredited laboratory shall be used, but it need not be accredited specifically for EPA Method 1633.1905SA10EA$ - 0
1010SPLoose absorbent media, Universal, 40 lb bag.1010SP150EA$ - 0
1011SPLoose absorbent media, Oil based liquids, 5 lb bag.1011SP20EA$ - 0
1020SPAbsorbent mat pad, Universal, dispenser box, indoor use, 100 ct.1020SP30EA$ - 0
1021SPAbsorbent mat pad, Oil only, dispenser box, indoor use, 100 ct.1021SP30EA$ - 0
1026SPGloves, NITRILE, 6 mil, medium 1EA=1BOX.1026SP12EA$ - 0
1027SPGloves, NITRILE, 6 mil, large, 1EA=1BOX.1027SP12EA$ - 0
1028SPGloves, NITRILE, 6 mil, Xlarge, 1EA=1BOX.1028SP35EA$ - 0
1029SPGloves, NITRILE, 6 mil, XXlarge, 1EA=1BOX.1029SP65EA$ - 0
1152SP5 GL, poly DR, new, OPN, pail w/screw top built in turning handle, DUAL UN 1H2/Y1.5/30 AND 1H2/Y30/S.1152SP3,000EA$ - 0
1153SP5 GL, poly DR, new, OPN, pail w/screw top built in turning handle, DUAL UN 1H2/Y1.5/30 AND 1H2/Y30/S, 1EA=25.1153SP200EA$ - 0
1155SP5 GL, poly DR, new, OPN, pail w/screw top lid with spout UN 1H2/Y1.5/30.1155SP3,000EA$ - 0
1330SP30 GL, poly DR, new, OPN, lever lock ring, lid, UN 1H2/Y180/S.1330SP60EA$ - 0
1332SP30 GL, poly DR, new, OPN, open head w/ring and lid, UN 1H2/Y180/S. 1 EA = 10 containers.1332SP60EA$ - 0
1342SP30 GL, metal DR, new, Removeable head, with bung, UN 1A2/Y1.4/100.1342SP1,000EA$ - 0
1402SP55 GL, poly DR, new, OPN, UN 1H2/Y, open top, new.1402SP60EA$ - 0
1472SP55 GL, metal DR, recon, removeable head with bung, UN 1A2/Y1.5/150.1472SP1,500EA$ - 0
1473SP55 GL, metal DR, recon, removeable head with bung, UN 1A2/Y1.5/150, 1EA=25.1473SP90EA$ - 0
1500SP85 GL, metal DR, new, OPN, EP lined, bolt ring, UN1A2/X435/S or UN1A2T/Y320/S.1500SP50EA$ - 0
1503SP85 GL, poly DR, new, OPN, UN1H2/Y130/S1503SP50EA$ - 0
1623SPBOX, 36"x36"x36", cardboard, with top and liner, UN 11G/X/.1623SP1,000EA$ - 0
1641SP275 GL, tote, poly, new, with pallet, UN 31HA1/Y.1641SP500EA$ - 0
1642SP275 GL, tote, poly, new, with pallet, UN 31HA1/Y, 1EA=5.1642SP50EA$ - 0
1654SP4 Ft fiber fluorescent bulb box (capacity 85 bulbs), UN 1G/Y50/S.1654SP125EA$ - 0
1668SP8 Ft fiber fluorescent bulb box (capacity 70 bulbs), UN 1G/Y50/S.1668SP30EA$ - 0

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .