This document is a specifications and existing conditions reference file for a federal contract opportunity titled "Repair Fence Refueling Parking Area, POL Fence" (Project MXDP 25-1011).

The scope of work includes repair and modification of the perimeter fence surrounding a Petroleum, Oil, and Lubricants (POL) refueling parking area. Key work elements include: relocation of fence sections (shown conceptually in red on the site plan); installation of approximately 460 linear feet of electrical conduit; installation of bollards at a specified location; removal of existing signs, rims, and fire extinguisher equipment; and replacement of various safety signage after construction. The fence system controls access through nine gates with varying opening widths: two 20-foot sliding gates (front and back entrances), three 20-foot swing gates, and four 4-foot personnel gates, plus one 12-foot swing gate. The document includes detailed photographic documentation of existing conditions showing the current fence, gates, and equipment locations, along with an annotated site plan identifying gate positions, bollard locations, and electrical conduit routing. Signage requirements for replacement include one eyewash fountain sign, two numbered identification signs, two reflectors, six danger signs, eighteen small warning/aviso signs, three large warning/aviso signs, two moving gate warning signs, one speed limit sign, one stop sign, one check tires sign, and one no POVs sign. The document serves as a reference for bidders to understand existing conditions, scope boundaries, and specific installation requirements.

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Repair Fence Refueling Parking Area, POL Fence POL Fence Existing Conditions

MXDP 25-1011

POL Fence Existing Conditions

Front Entrance Sliding Gate and 1st Personnel Gate

1st Swing Gate

2nd Personnel Gate

2nd Swing Gate, 3rd Personnel Gates

Back Entrance Sliding Gate

Bollards Location (conceptual only)

Relocate Fence (conceptual only)

3rd Swing Gate

4th Personnel Gate

5th Personnel Gate (additional)

POL Fence Scope of Work

Electrical conduit, 460 LF. (Approximate location and length)

Gates and Bollards location

Gate Dimensions - Opening

Front entrance – Sliding Gate - 20 feet

1st Personnel Gate – 4 feet

1st Swing Gate – 20 feet

2nd Personnel Gate – 4 feet

2nd Swing Gate – 20 feet

3rd Personnel Gate – 4 feet

Back Entrance – Sliding Gate - 20 feet

3rd Swing Gate – 12 feet

4th Personnel Gate – 4 feet

5th Personnel Gate – 4 feet

Signs/Rims – remove

Ex.1 Ex.2

Ex.3 Ex.4 Ex.5

Signs – replace after construction

Eyes wash – 1

Numbered – 2

Reflectors – 2

Danger – 6 Warning/Aviso (small) – 18

Warning/Aviso (large) – 3 Moving Gate – 2

Speed limit – 1 Stop Sign – 1

Check Tires – 1

No POVs – 1