This document is an attachment to a federal contract opportunity that outlines additional design requirements for various rooms and spaces, including single-use bathrooms, a housekeeping closet, a lactation room, and a canteen office.

For the single-use bathrooms, the requirements include specifications for wall and floor tile, countertops, sinks, toilets, accessories, and automation for the doors. The housekeeping closet requires unglazed quarry tile flooring, ceramic tile wainscoting, and a floor sink. The lactation room calls for luxury vinyl tile flooring, a solid surface countertop, and a privacy partition. The canteen office specifies painted walls and luxury vinyl tile flooring.

The related federal contract opportunity is Solicitation Number 36C24124R0028 for the repair of the sewer and bathrooms in Building 1, issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 1.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment 4

ADDITIONAL DESIGN REQUIREMENTS

REQUIREMENTS FOR ALL SPACES:

Ceilings: ACT-24”x24” Acoustical Ceiling Tile and White ¾” Grid system; BOD – Armstrong optima, with prelude XL grid.

Lighting: LED 2’x2’ fixtures meeting the VA design guide lamination requirements; Provide new lighting and light control based on the final layout of the room.

Walls: Light gauge metal framing and drywall to support final layout and design. Provide all necessary wood blocking for installation of scope and design items.

Floors: All floor preparation including self-leveling and subsurface preparation shall be provided. See door threshold requirements below.

Doors: New hollow metal door frames, wood doors, and associated hardware, with ADA compliant marble thresholds.

Safety and Security Systems:

-Relocate existing security equipment to new room location and reconnect to existing security devices that are located throughout canteen store and cafeteria.

-Provide necessary fire alarm devices and system tie-ins to meet code requirements.

-Modify fire protection sprinkler system as necessary to meet code requirements.

SINGLE USE BATHROOMS (4 COUNT):

Room Finishes:

Wall: 12”x24” Colorbody Porcelain Tile-installed stacked, floor to ceiling; Epoxy Grout.

-Minimum MOHS scratch hardness: 8.0 -Breaking Strength >275lbs.

- Equal to Daltile Fabrique Crème Linen P686 Wall Accent: Glass Wall Tile Mosaic Accent-mesh mounted, in a linear pattern, 4” minimum lengths.

-12” high accent on every wall -4x random straight stacked Glass Mosaic -Must be glass with a glossy finish

- Colorways must be monochromatic and be available in neutral tones and light to medium blue tones -Equal to Daltile Cascading Waters Glass Mosaic Floor: 12”x12” Colorbody Porcelain Tile; Epoxy Grout.

-Minimum MOHS scratch hardness: 8.0 -Breaking Strength >275 lbs.

-Unpolished DCOF wet minimum >0.42 -Equal to Daltile Fabrique Gris Linen P690 Trim: Satin Anodized Aluminum Metal Tile Trim-applied to coves and outside corners.

-Equal to Schluter to meet maintenance and hygienic requirements.

-Quadec for outside corners And Schluter Dilex-AHK Cove trim to integrate with Quadec outside corners.

Lavatory Requirements:

Counters: Minimum 42” solid surface counter-wall mounted.

-4” apron on three sides -Solid Surface shall be equal to Wilsonart Dupont Zodiaq Quartz – Dove Grey and Papyrus.

Sinks: Undermount white porcelain ADA compliant sink basins

-Piping to be insulated/wrapped under sink -Hose bib under each sink -Auto Sensor Faucets with mixing valves -24”x36” mirror over sinks Toilets: Porcelain; wall mounted with all associated plumbing; with Auto Flush sensor Accessories:

-42”, 36” and flip-up style peened Stainless grab bars with concealed hardware to comply with ABA.

-Semi-recessed stainless steel trash receptacle -Surface mounted paper towel, toilet paper, sanitary napkin, soap dispenser -2 coat hooks behind each door -Stainless steel baby changing station (2 count) Automation: Each bathroom door must have an automatic door operator with push buttons on the corridor and room side of the door.

HOUSEKEEPING CLOSET

Room Finishes:

Floor and 4” high base: Unglazed Quarry Tile; Epoxy Grout Walls: Glazed Ceramic tile wainscotting-all walls up to 4’-0”H; Epoxy Grout.

-Specialty Coating Epoxy paint on walls above wainscotting Sink: Floor sink

- Mixing valve and all associated plumbing

LACTATION ROOM

Room Finishes:

Wall: Painted gypsum/concrete.

-6” High Millwork Contoured Wall base equal to Johnsonite Monarch.

Wall Accent: Custom photography Digital print on Type II wallcovering on one long wall.

-Equal to Koroseal Interior Products Digital Lab Option E Wallcoverings.

Floor: Luxury Vinyl Tile (LVT) Wood look 6”wide planks -40 mil wear layer equal to Mannington LVT Amtico Wood Room Requirements:

Countertop: Minimum 72” solid surface counter with 4” apron-wall mounted.

- Solid Surface shall be equal to Wilsonart Dupont Zodiaq Quartz – Papyrus -Coordinate countertop height/bottom of apron with undercounter refrigerator, to be provided.

Sink: Undermount white porcelain ADA compliant sink basin -Piping to be insulated/wrapped under sink -Hose bib under sink -Auto Sensor Faucet with mixing valve Privacy Partition: 48”wide x 96”H x 3/8”T Class A fire rated PETG freestanding-must be anchored to the floor.

- Frame /hardware is clear anodized.

-Opaque colored finish in Wave Texture equal to Varia Iltuo Cantilevered from 3Form

CANTEEN OFFICE

Room Finishes:

Walls: Painted gypsum/concrete Floors: LVT plank floor w/ 4” rubber base