SOW Attachment (1) Contract Drawings.pdf
PDF 2 MB Posted
- Attached to
- NSWCPD Building 77H Fuel Pump Controller Repairs Federal contract opportunity
- Solicitation number
- N6449823R4003
About this file
This solicitation is for repair and maintenance services for the fuel pump controller system located in Building 77H and the adjacent exterior fuel storage facility at the Naval Surface Warfare Center Philadelphia Division in Philadelphia, Pennsylvania. The work includes replacing various piping, valves, controls, instrumentation and other elements to return the fuel distribution and monitoring system to fully operational condition. The period of performance is 160 days from notice to proceed. A site visit is strongly encouraged and details will be provided in the solicitation. The acquisition will use lowest price technically acceptable source selection with evaluation factors of bonding, past performance and price. Initial proposals are due by January 25, 2023. Award will be made without discussions based on initial proposals. The solicitation number is N6449823R4003 and will be issued on December 19, 2022 via SAM.gov.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| N6449823R4003 Amendment 0001.pdf | ||
| SOW Attachment (2) Control Panel As-Built Dwgs.pdf | ||
| SOW Attachment (5) Requirements for Contractor Lift Operations.pdf | ||
| SOW Attachment (6) Activity Hazard Analysis Form.docx | DOCX document | |
| SOW Attachment (9) SECNAV 5512.pdf | ||
| N6449823R4003.pdf | ||
| SOW Attachment (3) Historical Reference Drawing.pdf | ||
| SOW Attachment (7) Mobile Construction Equipment Checklist.pdf | ||
| SOW Attachment (10) Eng_Form_4025-R.pdf | ||
| SOW Attachment (4) NSWCPD Entry Screening Assessment 1 SEPT 2022 Rev 13.pdf | ||
| Attachment (11) Bid Bond SF24.pdf | ||
| Attachment (12) Past Performance Questionnaire (PPQ).doc | DOC document | |
| SOW Attachment (8) Contractor Production Report Form.doc | DOC document | |
| Attachment (13) Construction Cost Breakdown.xlsx | XLSX spreadsheet |
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NAVAL SURFACE WARFARE CENTER
PHILADELPHIA DIVISION
PHILADELPHIA NAVY YARD ANNEX
PHILADELPHIA, PENNSYLVANIA
BUILDING 77H FUEL PUMP CONTROLLER
SYSTEM REPAIRS (PHASE 2)
VICINITY PLAN LOCATION PLAN
G-001
3.
.2
3.
.2
N .T
.S
CO
VE
R
SH
EE
T
SECURITY BADGING OFFICE
CONTRACT ADMINISTRATION AND
OVERSIGHT OFFICES
PROJECT SITE
15 4 3 2
A
B
C
D
5 14 3 2
PROJECT NORTH
DR
AW
N B
Y:
N
AV
AL
S U
RF
AC
E W
AR
FA
RE
C
EN
TE
R
PH
IL
AD
EL
PH
IA
, P
A N
SW
C
P D
IN
FR
A
ST
R U
C
TU
R E
A C
Q U
IS
IT
IO
N
S U
P P
O R
T
DE
SI
GN
ED
B
Y:
DW
G N
AM
E:
SH
EE
T
SI
ZE
CO
DE
SA
VE
D
AT
E:
SC
AL
E:
PL
O
T
DA
TE
N O
TE
S:
of 04
BU
IL
DI
N
G
H
FL
O O
R
E
XT
ER
IO
R
FU
EL
S
TO
RA
GE
F
AC
IL
IT
Y
FU
EL
P
U M
P
CO
N
TR
O
LL
ER
S
YS
TE
M R
EP
AI
RS
(P
HA
SE
AR
CH
D (2
4-in
. x
4-in
REVISION TABLE
SYM DESCRIPTION DATE APPR
FINAL DRAWING 03/21/22
RM
S
RM
S
ST
AT
EM
EN
T O
F W
O
RK
A
TT
AC
HM
EN
T
(1
15 4 3 2
A
B
C
D
5 14 3 2
PROJECT NORTH
DR
AW
N B
Y:
N
AV
AL
S U
RF
AC
E W
AR
FA
RE
C
EN
TE
R
PH
IL
AD
EL
PH
IA
, P
A N
SW
C
P D
IN
FR
A
ST
R U
C
TU
R E
A C
Q U
IS
IT
IO
N
S U
P P
O R
T
DE
SI
GN
ED
B
Y:
DW
G N
AM
E:
SH
EE
T
SI
ZE
CO
DE
SA
VE
D
AT
E:
SC
AL
E:
PL
O
T
DA
TE
N O
TE
S:
of 04
BU
IL
DI
N
G
H
FL
O O
R
E
XT
ER
IO
R
FU
EL
S
TO
RA
GE
F
AC
IL
IT
Y
FU
EL
P
U M
P
CO
N
TR
O
LL
ER
S
YS
TE
M R
EP
AI
RS
(P
HA
SE
AR
CH
D (2
4-in
. x
4-in
REVISION TABLE
SYM DESCRIPTION DATE APPR
FINAL DRAWING 03/21/22
RM
S
RM
S
ST
AT
EM
EN
T O
F W
O
RK
A
TT
AC
HM
EN
T
(1
)GENERAL NOTES:
1. REFER TO PHOTOGRAPHS ON SHEET MEP-901 FOR REPRESENTATIVE IMAGES OF EXISTING
CONDITIONS.
2. FUEL PIPING SHOWN IS DIAGRAMMATIC AND MAY NOT REPRESENT THE ACTUAL FIELD LAYOUT.
VERIFY ALL DIMENSIONS AND PIPING LAYOUT PRIOR TO STARTING ANY NEW WORK. DRAWING
DOES NOT SHOW ALL PIPING AND COMPONENTS.
3. PROVIDE ENCLOSURES WITH A NEMA 4X RATING, IP65 RATING, OR BETTER.
4. DRAWINGS DO NOT INDICATE ALL REQUIRED FEATURES OF INSTALLED MATERIAL. REFER TO
CONTRACT STATEMENT OF WORK FOR ADDITIONAL REQUIREMENTS AND DETAILED
SPECIFICATIONS.
5. ALL ELECTRICAL WORK AND MATERIAL SHALL CONFORM TO NATIONAL FIRE PROTECTION
ASSOCIATION (NFPA) 70 NATIONAL ELECTRIC CODE (NEC) 2020 EDITION. ALL WORK AND MATERIAL
SHALL BE IN ACCORDANCE WITH THE NEC FOR DIVISION 1 CLASS 1 GROUP D HAZARDOUS
LOCATIONS. ALL WIRING SHALL BE PROVIDED IN RIGID METALLIC CONDUIT (RMC).
6. ALL MATERIAL AND EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE
MANUFACTURER'S WRITTEN INSTRUCTIONS. RECOMMENDATIONS NECESSARY FOR A COMPLETE
AND USEABLE SYSTEM SHALL BE IMPLEMENTED AT NO ADDITIONAL COST TO THE GOVERNMENT.
7. LABEL EACH MOTOR OPERATED VALVE WITH THE POWER SOURCE PANEL NAME, PANEL LOCATION, AND CIRCUIT NUMBER. LABELING SHALL BE WEATHER AND UV RESISTANT.
8. ALL CONTROL AND COMMUNICATION WIRES SHALL BE LABELED AT EACH TERMINATION POINT AND WHERE SPLICED. LABELING SHALL CONFORM TO THE NOTATIONS ON THE CONTRACTOR PROVIDED
WIRING SCHEMATIC.
9. STRANDED WIRING TERMINATIONS SHALL USE CRIMP-TYPE OR SIMILAR TERMINALS COMPATIBLE WITH EQUIPMENT TERMINATION POINTS AT ALL LOCATIONS. TERMINALS SHALL BE LISTED WITH
THE UNDERWRITER'S LABORATORY (UL). TERMINALS SHALL BE USED FOR THE WIRE SIZE OF
WHICH THEY ARE LISTED FOR.
10. PROVIDE EACH NEW INSTRUMENT AND ACTUATOR WITH A DEDICATED WEATHER PROOF STORAGE CANISTER SUITABLE FOR STORAGE OF WIRING DIAGRAMS AND OWNER'S MANUALS AND SIZED TO
HOLD THE MANUALS AND DRAWINGS. FASTEN THE CANISTER ADJACENT TO THE INSTRUMENT OR
ACTUATOR USING AN APPROVED UV RESISTANT AND DURABLE FASTENER SYSTEM.
11. CALIBRATE INSTRUMENTS AS RECOMMENDED BY THE MANUFACTURER. PROVIDE PROGRAMMING
AND GRAPHICAL INTERFACE FOR NEW MONITORING POINTS.
B1 BUILDING 77H PLAN - NEW WORK
CP CONTROL PANEL
FOP FUEL OIL PURIFIER
FOPV FUEL OIL PUMPS AND VALVES
MOV MOTOR OPERATED VALVE
NEMA NATIONAL ELECTRIC MANUFACTURERS ASSOCIATION
RMC RIGID METALLIC CONDUIT
SPST SINGLE POLE SINGLE THROW
TYP TYPICAL
UV ULTRAVIOLET
NEW WORK KEYNOTES:
1. EXISTING CP-FOPV AND CP-FOP CONTROL PANELS. REFER TO CONTRACT DOCUMENTS FOR WIRING
SCHEMATICS AND PRODUCT DATA ON CONTROLLER MODULES.
2. REMOVE EXISTING VALVE ACTUATORS AND DISPOSE OF MATERIAL OFFSITE. REMOVE EXISTING
CONTROL AND POWER WIRING BACK TO CP-FOPV SOURCE.
3. PROVIDE NEW MOV VALVE ACTUATOR FOR VALVES 6-INCH FILL VALVES YV-1B AND YV-4B. EXISTING
VALVES ARE BALL VALVES WITH VALVE STEMS AND STAINLESS STEEL BODIES. PROVIDE HARDWARE
FOR STEM MOUNTING AS REQUIRED. PROVIDE NEW CONTROL AND POWER WIRING FROM PANEL
CP-FOPV TO THE VALVE USING EXISTING CONDUIT WHERE AVAILABLE. SEE NEW WORK KEYNOTE 11
FOR MORE DETAILS. PROVIDE NEW CONDUIT AND FITTINGS AS NECESSARY FOR FINAL
TERMINATIONS.
4. PROVIDE NEW MOV VALVE ACTUATOR FOR VALVES 6-INCH SUPPLY VALVES TF-E5 AND TF-E8.
EXISTING VALVES ARE BALL VALVES WITH VALVE STEMS AND CAST IRON BODIES. PROVIDE
HARDWARE FOR STEM MOUNTING AS REQUIRED. PROVIDE NEW CONTROL AND POWER WIRING
FROM PANEL CP-FOPV TO THE VALVE USING EXISTING CONDUIT WHERE AVAILABLE. SEE NEW WORK KEYNOTE 11 FOR MORE DETAILS. PROVIDE NEW CONDUIT AND FITTINGS AS NECESSARY FOR FINAL
TERMINATIONS.
5. REMOVE EXISTING 2-INCH HERSEY FLOW INSTRUMENT AND REPLACE WITH A FLANGED STAINLESS
STEEL SPOOL. REMOVE EXISTING CONTROL AND POWER WIRING BACK TO CP-FOPV SOURCE.
CONTAIN, COLLECT AND DISPOSE OF DIESEL FUEL IN ACCORDANCE WITH LOCAL, STATE, AND
FEDERAL REQUIREMENTS. LEAK TEST NEW PIPING PRIOR TO PUTTING SYSTEM BACK INTO SERVICE.
6. PROVIDE A CLAMP-ON ULTRASONIC FLOW METER RATED FOR 0-500 GALLON PER MINUTE AND SUITABLE FOR 3-INCH STAINLESS STEEL PIPING. LOCATE FLOW METER ON 3-INCH SUPPLY PIPING
DOWNSTREAM OF SUPPLY PUMPS WITH SUFFICIENT SPACING BETWEEN THE FLOW METER AND
TURBULENCE SOURCES UPSTREAM OR DOWNSTREAM OF THE FLOW METER. PROVIDE NEW
CONTROL AND POWER WIRING FROM PANEL CP-FOPV TO THE FLOW INSTRUMENT USING EXISTING
CONDUIT WHERE AVAILABLE. PROVIDE NEW CONDUIT AND FITTINGS AS NECESSARY AT FIELD
INTERFACE POINTS.
7. CALIBRATE EXISTING TEMPERATURE INSTRUMENT TRANSMITTER (TYP. OF 2).
8. CALIBRATE EXISTING FLOW INSTRUMENT TRANSMITTER.
9. PROVIDE NEW CIRCUIT BREAKERS AND POWER FROM CP-FOPV TO PROVIDE EQUIPMENT AND
INSTRUMENT POWER TO NEW FIELD INSTRUMENTS. CIRCUIT BREAKERS SHALL BE SUITABLE FOR
THE VOLTAGE AND LOAD REQUIREMENTS AND SHALL COMPLY WITH THE NEC. WHERE SIZED IN
ACCORDANCE WITH THE NEC, MULTIPLE INSTRUMENTS MAY USE SHARED BRANCH CIRCUITS AS
PERMITTED BY THE NEC. PROVIDE WITH DIN RAIL MOUNTING ACCESSORIES AS REQUIRED. REFER
TO DRAWING MEP-501 FOR MORE DETAILS.
10. PROVIDE NEW SPST RELAYS TO PROVIDE REMOTE OPERATION OF MOVS AS REQUIRED IN
STATEMENT OF WORK. REFER TO DRAWING MEP-501 FOR MORE DETAILS.
11. EXISTING CONDUIT PATHWAY FROM BULK FUEL STORAGE FACILITY TO PANEL CP-FOPV. USE EXISTING CONDUIT TO ROUTE NEW WIRING FROM FIELD EQUIPMENT AND INSTRUMENTS TO PANEL CP-FOPV. WHERE REQUIRED AND AUTHORIZED BY THE CONTRACTING OFFICER UNDER CLIN 0002, PROVIDE NEW RMC AND ANCILLARY FITTINGS, CONNECTORS, FASTENERS, AND HARDWARE WHEN
EXISTING CROSS-SECTIONAL AREA IS NOT AVAILABLE FOR NEW CONDUCTORS.
SCALE: 1" = 15'-0"
D5
MEP-901
D4/B5
MEP-901
D3
MEP-901
D2
MEP-901
B4
MEP-901
B3
MEP-901
B2
MEP-901
9 101
MEP-101
ABBREVIATIONS:
N
EW
W O
RK
S
IT
E
PL
AN
AS
N
O
TE
D
AutoCAD SHX Text
BUILDING 77H
L1
L2
CB-1P
F1
REVERSING
CONTACTOR
T1
T2
T3
F2
STOP
CLOSE
OPEN
120VAC / 1P / 60HZ
MOTOR
MECHANICAL
INTERLOCK
C
O
C
CR-C
CR-O
CR-S
SECONDARY
120VAC
PRIMARY
OFF
LOCAL
(HAND)
REMOTE
(AUTO)
O
LSC
LSO
ZIT
(MOV) 4 - 20 mA
I IN
I IN
24VDC
ANALOG
INPUT
(EX. SPARE)
FIT
(FE) 4 - 20 mA
I IN
I IN
24VDC
ANALOG
INPUT
(REUSE I7/01)
15 4 3 2
A
B
C
D
5 14 3 2
PROJECT NORTH
DR
AW
N B
Y:
N
AV
AL
S U
RF
AC
E W
AR
FA
RE
C
EN
TE
R
PH
IL
AD
EL
PH
IA
, P
A N
SW
C
P D
IN
FR
A
ST
R U
C
TU
R E
A C
Q U
IS
IT
IO
N
S U
P P
O R
T
DE
SI
GN
ED
B
Y:
DW
G N
AM
E:
SH
EE
T
SI
ZE
CO
DE
SA
VE
D
AT
E:
SC
AL
E:
PL
O
T
DA
TE
N O
TE
S:
of 04
BU
IL
DI
N
G
H
FL
O O
R
E
XT
ER
IO
R
FU
EL
S
TO
RA
GE
F
AC
IL
IT
Y
FU
EL
P
U M
P
CO
N
TR
O
LL
ER
S
YS
TE
M R
EP
AI
RS
(P
HA
SE
AR
CH
D (2
4-in
. x
4-in
REVISION TABLE
SYM DESCRIPTION DATE APPR
FINAL DRAWING 03/21/22
RM
S
RM
S
ST
AT
EM
EN
T O
F W
O
RK
A
TT
AC
HM
EN
T
(1
)GENERAL NOTES:
1. DRAWINGS DO NOT INDICATE ALL REQUIRED FEATURES OF INSTALLED MATERIAL. REFER TO
CONTRACT STATEMENT OF WORK FOR ADDITIONAL REQUIREMENTS AND DETAILED
SPECIFICATIONS. REFER TO SOW ATTACHMENTS FOR DETAILS ON CP-FOPV.
2. ALL ELECTRICAL WORK AND MATERIAL SHALL CONFORM TO NATIONAL FIRE PROTECTION
ASSOCIATION (NFPA) 70 NATIONAL ELECTRIC CODE (NEC) 2020 EDITION. ALL WORK AND MATERIAL
SHALL BE IN ACCORDANCE WITH THE NEC FOR DIVISION 1 CLASS 1 GROUP D HAZARDOUS
LOCATIONS IN ALL EXTERIOR LOCATIONS. ALL WIRING SHALL BE PROVIDED IN RIGID METALLIC CONDUIT (RMC) IN EXTERIOR LOCATIONS AND ELECTRICAL METALLIC CONDUIT (EMT) IN INTERIOR
LOCATIONS UNLESS OTHERWISE NOTED.
3. ALL MATERIAL AND EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S
WRITTEN INSTRUCTIONS. RECOMMENDATIONS NECESSARY FOR A COMPLETE AND USEABLE
SYSTEM SHALL BE IMPLEMENTED AT NO ADDITIONAL COST TO THE GOVERNMENT.
4. LABEL EACH MOTOR OPERATED VALVE WITH THE POWER SOURCE PANEL NAME, PANEL LOCATION, AND CIRCUIT NUMBER. LABELING SHALL BE WEATHER AND UV RESISTANT.
5. ALL CONTROL AND COMMUNICATION WIRES SHALL BE LABELED AT EACH TERMINATION POINT AND WHERE SPLICED. LABELING SHALL CONFORM TO THE NOTATIONS ON THE CONTRACTOR PROVIDED
WIRING SCHEMATIC.
6. STRANDED WIRING TERMINATIONS SHALL USE CRIMP-TYPE OR SIMILAR TERMINALS COMPATIBLE WITH EQUIPMENT TERMINATION POINTS AT ALL LOCATIONS. TERMINALS SHALL BE LISTED WITH THE UNDERWRITER'S LABORATORY (UL). TERMINALS SHALL BE USED FOR THE WIRE SIZE OF WHICH
THEY ARE LISTED FOR.
7. PROVIDE EACH NEW INSTRUMENT AND ACTUATOR WITH A DEDICATED WEATHER PROOF STORAGE CANISTER SUITABLE FOR STORAGE OF WIRING DIAGRAMS AND OWNER'S MANUALS AND SIZED TO
HOLD THE MANUALS AND DRAWINGS. FASTEN THE CANISTER ADJACENT TO THE INSTRUMENT OR
ACTUATOR USING AN APPROVED UV RESISTANT AND DURABLE FASTENER SYSTEM.
8. CALIBRATE INSTRUMENTS AS RECOMMENDED BY THE MANUFACTURER. PROVIDE PROGRAMMING
AND GRAPHICAL INTERFACE FOR NEW MONITORING POINTS.
C5 MOTOR OPERATED VALVE CONTROLS
C3 INSTRUMENT TRANSMITTERS
C CLOSE
CB CIRCUIT BREAKER
CP CONTROL PANEL
CR CURRENT RELAY
LIT LEVEL INSTRUMENT TRANSMITTER
FE FLOW ELEMENT
FIT FLOW INSTRUMENT TRANSMITTER
FOPV FUEL OIL PUMPS AND VALVES
LSC LIMIT SWITCH (CLOSE)
LSO LIMIT SWITCH (OPEN)
MOV MOTOR OPERATED VALVE
O OPEN
S STOP
SOP SEQUENCE OF OPERATION
SOW STATEMENT OF WORK
SPDT SINGLE POLE DOUBLE THROW
SPST SINGLE POLE SINGLE THROW
VAC VOLTS ALTERNATING CURRENT
ZIT POSITION INDICATING TRANSMITTER
NEW WORK KEYNOTES:
1. PROVIDE VALVE ACTUATOR WITH INTEGRATED POWER DISCONNECT. DISCONNECT MAY BE IN THE
FORM OF AN INTEGRATED CIRCUIT BREAKER.
2. PROVIDE VALVE ACTUATOR WITH SELF-POWERED MOTOR CONTROL CIRCUIT.
3. PROVIDE VALVE ACTUATOR WITH LOCAL-OFF-REMOTE SELECTOR SWITCH.
4. PROVIDE VALVE ACTUATOR WITH REVERSING CONTACTOR WITH MECHANICAL AND ELECTRICAL
INTERLOCKS FOR THE OPEN AND CLOSE COILS.
5. PROVIDE MOTOR WITH OVERLOAD PROTECTION.
6. PROVIDE REMOTE OPEN-CLOSE-STOP CIRCUITS FOR VALVE OPERATION FROM PANEL CP-FOPV.
PROVIDE SPST CURRENT RELAYS IN CP-FOPV FOR REMOTE START, STOP, AND CLOSE CONTROL
OF EACH VALVE ACTUATOR. PROVIDE WITH DIN RAIL MOUNTING ACCESSORIES AS REQUIRED.
SPDT RELAYS ARE ACCEPTABLE PROVIDED ONLY THE NC OR NO CONTACT TERMINAL IS USED TO COMPLETE THE CIRCUIT. CURRENT RELAYS SHALL BE RATED FOR 120VAC ON THE COIL AND AS
REQUIRED BY THE VALVE ACTUATOR MANUFACTURER ON THE SWITCHED CIRCUIT. PROVIDE
WIRING BETWEEN EACH VALVE ACTUATOR AND THE CP-FOPV PANEL LOCATED IN BUILDING 77H.
SIZE CONDUCTORS TO THE VALVE ACTUATOR AS REQUIRED BY THE NEC AND MANUFACTURER.
VOLTAGE DROP SHALL BE CONSIDERED AND MAY REQUIRE LARGER CONDUCTORS THAN
RECOMMENDED BY THE MANUFACTURER.
7. PROVIDE INSTRUMENT WIRING AS RECOMMENDED OR REQUIRED BY THE MANUFACTURER. ALL
WIRING SHALL BE SHIELDED. GROUND SHIELDING IN PANEL CP-FOPV. THE INSTRUMENT-SIDE
SHIELDING SHALL BE ELECTRICALLY INSULATED TO PREVENT TRANSMISSION OF
ELECTROMAGNETIC INTERFERENCE. WHERE VOLTAGE DROP EXCEEDS MANUFACTURER
REQUIREMENTS, INCREASE CONDUCTOR SIZE.
8. EXISTING ALLEN BRADLEY COMPACT 1769-IF4 ANALOG INPUT MODULE. SPARES AVAILABLE FOR
INSTRUMENT USE. MODULE DOES NOT PROVIDE LOOP POWER FOR ANALOG INPUTS.
TRANSMITTERS MUST PROVIDE POWER FOR LOOP OR A POWER SUPPLY MUST BE INCORPORATED
INTO THE INSTRUMENT LOOP BY THE CONTRACTOR. CURRENT TERMINALS HAVE AN INPUT
IMPEDANCE OF 250 OHMS AND OPERATE NORMALLY FROM 0-20 mA AND 4-20 mA.
9. PROVIDE MOV WITH POSITION INDICATING TRANSMITTER/CIRCUIT FOR FEEDBACK ON VALVE
POSITION (TYP. OF 4).
10. PROVIDE FLOW METER WITH FLOW INSTRUMENT TRANSMITTER. PROVIDE POWER AS REQUIRED
FOR INSTRUMENT AND TRANSMITTER.
11. PROVIDE 120 VAC POWER FROM CONTROL PANEL CP-FOPV.
7 8
MEP-501
TABLE 1 - MOV MOTOR SCHEDULE
MIN.
HORSEPOWER VOLTAGE PHASE FREQUENCY MAX. CURRENT SEC/90° (MIN/MAX)
12 HP 120 VAC 1-PHASE 60 HZ 5 AMPS 4.0-7.0
NOTES: (1) PROVIDE EXPLOSION PROOF ENCLOSURES (2) MOV MOTOR SCHEDULE APPLIES TO
MOV ACTUATORS TF-E5, TF-E8, YV-1B, AND YV-4B.
ABBREVIATIONS:
TABLE 2 - ALARM INTERLOCK SCHEDULE
INSTRUMENT
TRANSMITTER ALARM SET POINT AFFECTED EQUIP ALARM INTERLOCK
LIT 1 HIGH HIGH LEVEL TANK T-4 171,500 GALLONS PUMP P-6 AND MOV YV-1B IN REMOTE MODE: (1) DE-ENERGIZE PUMP; (2) CLOSE VALVE.
LIT 4 HIGH HIGH LEVEL TANK T-5 171,500 GALLONS PUMP P-6 AND MOV YV-4B IN REMOTE MODE: (1) DE-ENERGIZE PUMP; (2) CLOSE VALVE.
LIT 1 LOW LEVEL TANK T-4 17,500 GALLONS PUMPS 3A, 7A, & 7B AND MOV
TF-E5
IN REMOTE MODE: (1) DE-ENERGIZE PUMPS; (2) CLOSE VALVE.
LIT 4 LOW LEVEL TANK T-5 17,500 GALLONS PUMPS 3A, 7A, & 7B AND MOV
TF-E8
IN REMOTE MODE: (1) DE-ENERGIZE PUMPS; (2) CLOSE VALVE.
FIT 22 LOW FLOW FE 22 17.5 GPM PUMPS 3A, 7A, & 7B
IN REMOTE MODE: (1) DE-ENERGIZE PUMPS IF FLOW IS EQUAL TO OR LESS THAN
SET POINT FOR MORE THAN FIVE (5) SECONDS WHILE PUMP 3A, 7A, 7B, OR ANY
COMBINATION THEREOF ARE RUNNING.
M O
TO
R
IN
ST
RU
M
EN
T
DE
TA
IL
S
N /A
VALVE SEQUENCE OF OPERATION:
IN "OFF" POSITION
1. VALVE OPERATED BY HAND-OPERATING MECHANISM ONLY.
IN "REMOTE (AUTO)" POSITION
1. IF REMOTE "OPEN" RELAY CIRCUIT IS COMPLETED, ASSOCIATED VALVE OPENS UNTIL (A) LIMIT
SWITCH OPEN OR TORQUE SWITCH IS ENGAGED OR (B) UNTIL THE LOCAL STOP PUSHBUTTON IS
PRESSED OR (C) REMOTE "STOP" RELAY CIRCUIT IS COMPLETED.
2. IF REMOTE "CLOSE" RELAY CIRCUIT IS COMPLETED, ASSOCIATED VALVE CLOSES (A) UNTIL LIMIT SWITCH CLOSE OR TORQUE SWITCH IS ENGAGED OR (B) UNTIL THE LOCAL STOP PUSHBUTTON IS
PRESSED OR (C) REMOTE "STOP" RELAY CIRCUIT IS COMPLETED.
3. WHEN ALARM CONDITION IN TABLE 2 IS PRESENT, PERFORM ASSOCIATED ALARM INTERLOCK
FUNCTION FOR APPLICABLE VALVE(S).
IN "LOCAL (HAND)" POSITION
1. WHEN "OPEN" PUSHBUTTON IS PRESSED, VALVE OPENS UNTIL (A) LIMIT SWITCH OPEN OR TORQUE
SWITCH IS ENGAGED OR (B) THE LOCAL STOP PUSHBUTTON IS PRESSED.
2. WHEN "CLOSE" PUSHBUTTON IS PRESSED, VALVE CLOSES UNTIL (A) LIMIT SWITCH CLOSE OR
TORQUE SWITCH IS ENGAGED OR (B) THE LOCAL STOP PUSHBUTTON IS PRESSED.
3. WHEN "STOP" PUSHBUTTON IS PRESSED, VALVE OPERATION IS STOPPED IN ITS CURRENT
POSITION.
GENERAL NOTES:
1. PHOTOGRAPHS ARE REPRESENTATIVE AND DO NOT REFLECT ALL CONDITIONS AT THE
WORK SITE.
2. PHOTOGRAPHY AND VIDEO CAPTURING ARE STRICTLY PROHIBITED. PHOTOGRAPHS AND
VIDEOS MAY ONLY BE CAPTURED AND/OR RECORDED BY A GOVERNMENT
REPRESENTATIVE USING A GOVERNMENT-ISSUED CAMERA RECORDING DEVICE.
D5 PHOTOGRAPH 1
NEW WORK KEYNOTES:
1. FUEL STORAGE TANK T-4 (175,000 GALLON CAPACITY).
2. STEEL BRIDGE SUPPORTING CONDUIT AND PIPING BETWEEN BUILDING 77H AND THE
EXTERIOR FUEL STORAGE FACILITY.
3. FUEL STORAGE TANK T-5 (175,000 GALLON CAPACITY).
4. APPROXIMATE LOCATION OF FUTURE ULTRASONIC FLOW METER.
5. EXISTING TEMPERATURE INSTRUMENT TRANSMITTER REQUIRING CALIBRATION
(TYPICAL OF TWO).
6. MOTOR OPERATED VALVE WITH ELECTRIC ACTUATOR ON 6-INCH SUPPLY FROM TANKS
T-4 AND T-5. TYPICAL OF TWO FOR TF-E5 AND TF-E8.
7. EXISTING INOPERABLE FLOW METER. REPLACE FLOW METER WITH STAINLESS STEEL
FLANGED SPOOL. CONDUIT MAY BE REPURPOSED FOR NEW ULTRASONIC FLOW METER.
8. MOTOR OPERATED VALVE WITH ELECTRIC ACTUATOR ON 6-INCH FILL TO TANK T-4.
TYPICAL OF TWO FOR YV-1B AND YV-4B.
9. BUILDING 77H.
10. CONDUIT AND PIPING ENTERING BUILDING 77H.
11. FUEL OIL CONTROL PANEL FOR PUMPS AND VALVES (CP-FOPV).
12. EXISTING COUPLING FOR VALVE ACTUATOR DRIVES.
MEP-101 D4 PHOTOGRAPH 2
D3 PHOTOGRAPH 3 D2 PHOTOGRAPH 4
6 6
B5 PHOTOGRAPH 5 B4 PHOTOGRAPH 6
B3 PHOTOGRAPH 7 B2 PHOTOGRAPH 8
A5 PHOTOGRAPH 9 A4 PHOTOGRAPH 10
AUTHORIZED FOR PUBLIC RELEASE; DISTRIBUTION UNLIMITED.
15 4 3 2
A
B
C
D
5 14 3 2
PROJECT NORTH
DR
AW
N B
Y:
N
AV
AL
S U
RF
AC
E W
AR
FA
RE
C
EN
TE
R
PH
IL
AD
EL
PH
IA
, P
A N
SW
C
P D
IN
FR
A
ST
R U
C
TU
R E
A C
Q U
IS
IT
IO
N
S U
P P
O R
T
DE
SI
GN
ED
B
Y:
DW
G N
AM
E:
SH
EE
T
SI
ZE
CO
DE
SA
VE
D
AT
E:
SC
AL
E:
PL
O
T
DA
TE
N O
TE
S:
of 04
BU
IL
DI
N
G
H
FL
O O
R
E
XT
ER
IO
R
FU
EL
S
TO
RA
GE
F
AC
IL
IT
Y
FU
EL
P
U M
P
CO
N
TR
O
LL
ER
S
YS
TE
M R
EP
AI
RS
(P
HA
SE
AR
CH
D (2
4-in
. x
4-in
REVISION TABLE
SYM DESCRIPTION DATE APPR
FINAL DRAWING 03/21/22
RM
S
RM
S
ST
AT
EM
EN
T O
F W
O
RK
A
TT
AC
HM
EN
T
(1
MEP-901
MEP-101 MEP-101 MEP-101
MEP-101MEP-101MEP-101MEP-101
MEP-101 MEP-101
PH
O
TO
GR
AP
HS
N /A
PRA ID #NSWCPD-002326
File details come from the government source that posted it. Updated .