SOW Attachment (1) Contract Drawings.pdf

PDF 2 MB Posted

Attached to
NSWCPD Building 77H Fuel Pump Controller Repairs Federal contract opportunity
Solicitation number
N6449823R4003
Issued by
Department of the Navy Naval Sea Systems Command

About this file

This solicitation is for repair and maintenance services for the fuel pump controller system located in Building 77H and the adjacent exterior fuel storage facility at the Naval Surface Warfare Center Philadelphia Division in Philadelphia, Pennsylvania. The work includes replacing various piping, valves, controls, instrumentation and other elements to return the fuel distribution and monitoring system to fully operational condition. The period of performance is 160 days from notice to proceed. A site visit is strongly encouraged and details will be provided in the solicitation. The acquisition will use lowest price technically acceptable source selection with evaluation factors of bonding, past performance and price. Initial proposals are due by January 25, 2023. Award will be made without discussions based on initial proposals. The solicitation number is N6449823R4003 and will be issued on December 19, 2022 via SAM.gov.

View the file

Other files for this federal contract opportunity

Show all 14

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NAVAL SURFACE WARFARE CENTER

PHILADELPHIA DIVISION

PHILADELPHIA NAVY YARD ANNEX

PHILADELPHIA, PENNSYLVANIA

BUILDING 77H FUEL PUMP CONTROLLER

SYSTEM REPAIRS (PHASE 2)

VICINITY PLAN LOCATION PLAN

G-001

3.

.2

3.

.2

N .T

.S

CO

VE

R

SH

EE

T

SECURITY BADGING OFFICE

CONTRACT ADMINISTRATION AND

OVERSIGHT OFFICES

PROJECT SITE

15 4 3 2

A

B

C

D

5 14 3 2

PROJECT NORTH

DR

AW

N B

Y:

N

AV

AL

S U

RF

AC

E W

AR

FA

RE

C

EN

TE

R

PH

IL

AD

EL

PH

IA

, P

A N

SW

C

P D

IN

FR

A

ST

R U

C

TU

R E

A C

Q U

IS

IT

IO

N

S U

P P

O R

T

DE

SI

GN

ED

B

Y:

DW

G N

AM

E:

SH

EE

T

SI

ZE

CO

DE

SA

VE

D

AT

E:

SC

AL

E:

PL

O

T

DA

TE

N O

TE

S:

of 04

BU

IL

DI

N

G

H

FL

O O

R

E

XT

ER

IO

R

FU

EL

S

TO

RA

GE

F

AC

IL

IT

Y

FU

EL

P

U M

P

CO

N

TR

O

LL

ER

S

YS

TE

M R

EP

AI

RS

(P

HA

SE

AR

CH

D (2

4-in

. x

4-in

REVISION TABLE

SYM DESCRIPTION DATE APPR

FINAL DRAWING 03/21/22

RM

S

RM

S

ST

AT

EM

EN

T O

F W

O

RK

A

TT

AC

HM

EN

T

(1

15 4 3 2

A

B

C

D

5 14 3 2

PROJECT NORTH

DR

AW

N B

Y:

N

AV

AL

S U

RF

AC

E W

AR

FA

RE

C

EN

TE

R

PH

IL

AD

EL

PH

IA

, P

A N

SW

C

P D

IN

FR

A

ST

R U

C

TU

R E

A C

Q U

IS

IT

IO

N

S U

P P

O R

T

DE

SI

GN

ED

B

Y:

DW

G N

AM

E:

SH

EE

T

SI

ZE

CO

DE

SA

VE

D

AT

E:

SC

AL

E:

PL

O

T

DA

TE

N O

TE

S:

of 04

BU

IL

DI

N

G

H

FL

O O

R

E

XT

ER

IO

R

FU

EL

S

TO

RA

GE

F

AC

IL

IT

Y

FU

EL

P

U M

P

CO

N

TR

O

LL

ER

S

YS

TE

M R

EP

AI

RS

(P

HA

SE

AR

CH

D (2

4-in

. x

4-in

REVISION TABLE

SYM DESCRIPTION DATE APPR

FINAL DRAWING 03/21/22

RM

S

RM

S

ST

AT

EM

EN

T O

F W

O

RK

A

TT

AC

HM

EN

T

(1

)GENERAL NOTES:

1. REFER TO PHOTOGRAPHS ON SHEET MEP-901 FOR REPRESENTATIVE IMAGES OF EXISTING

CONDITIONS.

2. FUEL PIPING SHOWN IS DIAGRAMMATIC AND MAY NOT REPRESENT THE ACTUAL FIELD LAYOUT.

VERIFY ALL DIMENSIONS AND PIPING LAYOUT PRIOR TO STARTING ANY NEW WORK. DRAWING

DOES NOT SHOW ALL PIPING AND COMPONENTS.

3. PROVIDE ENCLOSURES WITH A NEMA 4X RATING, IP65 RATING, OR BETTER.

4. DRAWINGS DO NOT INDICATE ALL REQUIRED FEATURES OF INSTALLED MATERIAL. REFER TO

CONTRACT STATEMENT OF WORK FOR ADDITIONAL REQUIREMENTS AND DETAILED

SPECIFICATIONS.

5. ALL ELECTRICAL WORK AND MATERIAL SHALL CONFORM TO NATIONAL FIRE PROTECTION

ASSOCIATION (NFPA) 70 NATIONAL ELECTRIC CODE (NEC) 2020 EDITION. ALL WORK AND MATERIAL

SHALL BE IN ACCORDANCE WITH THE NEC FOR DIVISION 1 CLASS 1 GROUP D HAZARDOUS

LOCATIONS. ALL WIRING SHALL BE PROVIDED IN RIGID METALLIC CONDUIT (RMC).

6. ALL MATERIAL AND EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE

MANUFACTURER'S WRITTEN INSTRUCTIONS. RECOMMENDATIONS NECESSARY FOR A COMPLETE

AND USEABLE SYSTEM SHALL BE IMPLEMENTED AT NO ADDITIONAL COST TO THE GOVERNMENT.

7. LABEL EACH MOTOR OPERATED VALVE WITH THE POWER SOURCE PANEL NAME, PANEL LOCATION, AND CIRCUIT NUMBER. LABELING SHALL BE WEATHER AND UV RESISTANT.

8. ALL CONTROL AND COMMUNICATION WIRES SHALL BE LABELED AT EACH TERMINATION POINT AND WHERE SPLICED. LABELING SHALL CONFORM TO THE NOTATIONS ON THE CONTRACTOR PROVIDED

WIRING SCHEMATIC.

9. STRANDED WIRING TERMINATIONS SHALL USE CRIMP-TYPE OR SIMILAR TERMINALS COMPATIBLE WITH EQUIPMENT TERMINATION POINTS AT ALL LOCATIONS. TERMINALS SHALL BE LISTED WITH

THE UNDERWRITER'S LABORATORY (UL). TERMINALS SHALL BE USED FOR THE WIRE SIZE OF

WHICH THEY ARE LISTED FOR.

10. PROVIDE EACH NEW INSTRUMENT AND ACTUATOR WITH A DEDICATED WEATHER PROOF STORAGE CANISTER SUITABLE FOR STORAGE OF WIRING DIAGRAMS AND OWNER'S MANUALS AND SIZED TO

HOLD THE MANUALS AND DRAWINGS. FASTEN THE CANISTER ADJACENT TO THE INSTRUMENT OR

ACTUATOR USING AN APPROVED UV RESISTANT AND DURABLE FASTENER SYSTEM.

11. CALIBRATE INSTRUMENTS AS RECOMMENDED BY THE MANUFACTURER. PROVIDE PROGRAMMING

AND GRAPHICAL INTERFACE FOR NEW MONITORING POINTS.

B1 BUILDING 77H PLAN - NEW WORK

CP CONTROL PANEL

FOP FUEL OIL PURIFIER

FOPV FUEL OIL PUMPS AND VALVES

MOV MOTOR OPERATED VALVE

NEMA NATIONAL ELECTRIC MANUFACTURERS ASSOCIATION

RMC RIGID METALLIC CONDUIT

SPST SINGLE POLE SINGLE THROW

TYP TYPICAL

UV ULTRAVIOLET

NEW WORK KEYNOTES:

1. EXISTING CP-FOPV AND CP-FOP CONTROL PANELS. REFER TO CONTRACT DOCUMENTS FOR WIRING

SCHEMATICS AND PRODUCT DATA ON CONTROLLER MODULES.

2. REMOVE EXISTING VALVE ACTUATORS AND DISPOSE OF MATERIAL OFFSITE. REMOVE EXISTING

CONTROL AND POWER WIRING BACK TO CP-FOPV SOURCE.

3. PROVIDE NEW MOV VALVE ACTUATOR FOR VALVES 6-INCH FILL VALVES YV-1B AND YV-4B. EXISTING

VALVES ARE BALL VALVES WITH VALVE STEMS AND STAINLESS STEEL BODIES. PROVIDE HARDWARE

FOR STEM MOUNTING AS REQUIRED. PROVIDE NEW CONTROL AND POWER WIRING FROM PANEL

CP-FOPV TO THE VALVE USING EXISTING CONDUIT WHERE AVAILABLE. SEE NEW WORK KEYNOTE 11

FOR MORE DETAILS. PROVIDE NEW CONDUIT AND FITTINGS AS NECESSARY FOR FINAL

TERMINATIONS.

4. PROVIDE NEW MOV VALVE ACTUATOR FOR VALVES 6-INCH SUPPLY VALVES TF-E5 AND TF-E8.

EXISTING VALVES ARE BALL VALVES WITH VALVE STEMS AND CAST IRON BODIES. PROVIDE

HARDWARE FOR STEM MOUNTING AS REQUIRED. PROVIDE NEW CONTROL AND POWER WIRING

FROM PANEL CP-FOPV TO THE VALVE USING EXISTING CONDUIT WHERE AVAILABLE. SEE NEW WORK KEYNOTE 11 FOR MORE DETAILS. PROVIDE NEW CONDUIT AND FITTINGS AS NECESSARY FOR FINAL

TERMINATIONS.

5. REMOVE EXISTING 2-INCH HERSEY FLOW INSTRUMENT AND REPLACE WITH A FLANGED STAINLESS

STEEL SPOOL. REMOVE EXISTING CONTROL AND POWER WIRING BACK TO CP-FOPV SOURCE.

CONTAIN, COLLECT AND DISPOSE OF DIESEL FUEL IN ACCORDANCE WITH LOCAL, STATE, AND

FEDERAL REQUIREMENTS. LEAK TEST NEW PIPING PRIOR TO PUTTING SYSTEM BACK INTO SERVICE.

6. PROVIDE A CLAMP-ON ULTRASONIC FLOW METER RATED FOR 0-500 GALLON PER MINUTE AND SUITABLE FOR 3-INCH STAINLESS STEEL PIPING. LOCATE FLOW METER ON 3-INCH SUPPLY PIPING

DOWNSTREAM OF SUPPLY PUMPS WITH SUFFICIENT SPACING BETWEEN THE FLOW METER AND

TURBULENCE SOURCES UPSTREAM OR DOWNSTREAM OF THE FLOW METER. PROVIDE NEW

CONTROL AND POWER WIRING FROM PANEL CP-FOPV TO THE FLOW INSTRUMENT USING EXISTING

CONDUIT WHERE AVAILABLE. PROVIDE NEW CONDUIT AND FITTINGS AS NECESSARY AT FIELD

INTERFACE POINTS.

7. CALIBRATE EXISTING TEMPERATURE INSTRUMENT TRANSMITTER (TYP. OF 2).

8. CALIBRATE EXISTING FLOW INSTRUMENT TRANSMITTER.

9. PROVIDE NEW CIRCUIT BREAKERS AND POWER FROM CP-FOPV TO PROVIDE EQUIPMENT AND

INSTRUMENT POWER TO NEW FIELD INSTRUMENTS. CIRCUIT BREAKERS SHALL BE SUITABLE FOR

THE VOLTAGE AND LOAD REQUIREMENTS AND SHALL COMPLY WITH THE NEC. WHERE SIZED IN

ACCORDANCE WITH THE NEC, MULTIPLE INSTRUMENTS MAY USE SHARED BRANCH CIRCUITS AS

PERMITTED BY THE NEC. PROVIDE WITH DIN RAIL MOUNTING ACCESSORIES AS REQUIRED. REFER

TO DRAWING MEP-501 FOR MORE DETAILS.

10. PROVIDE NEW SPST RELAYS TO PROVIDE REMOTE OPERATION OF MOVS AS REQUIRED IN

STATEMENT OF WORK. REFER TO DRAWING MEP-501 FOR MORE DETAILS.

11. EXISTING CONDUIT PATHWAY FROM BULK FUEL STORAGE FACILITY TO PANEL CP-FOPV. USE EXISTING CONDUIT TO ROUTE NEW WIRING FROM FIELD EQUIPMENT AND INSTRUMENTS TO PANEL CP-FOPV. WHERE REQUIRED AND AUTHORIZED BY THE CONTRACTING OFFICER UNDER CLIN 0002, PROVIDE NEW RMC AND ANCILLARY FITTINGS, CONNECTORS, FASTENERS, AND HARDWARE WHEN

EXISTING CROSS-SECTIONAL AREA IS NOT AVAILABLE FOR NEW CONDUCTORS.

SCALE: 1" = 15'-0"

D5

MEP-901

D4/B5

MEP-901

D3

MEP-901

D2

MEP-901

B4

MEP-901

B3

MEP-901

B2

MEP-901

9 101

MEP-101

ABBREVIATIONS:

N

EW

W O

RK

S

IT

E

PL

AN

AS

N

O

TE

D

AutoCAD SHX Text

BUILDING 77H

L1

L2

CB-1P

F1

REVERSING

CONTACTOR

T1

T2

T3

F2

STOP

CLOSE

OPEN

120VAC / 1P / 60HZ

MOTOR

MECHANICAL

INTERLOCK

C

O

C

CR-C

CR-O

CR-S

SECONDARY

120VAC

PRIMARY

OFF

LOCAL

(HAND)

REMOTE

(AUTO)

O

LSC

LSO

ZIT

(MOV) 4 - 20 mA

I IN

I IN

24VDC

ANALOG

INPUT

(EX. SPARE)

FIT

(FE) 4 - 20 mA

I IN

I IN

24VDC

ANALOG

INPUT

(REUSE I7/01)

15 4 3 2

A

B

C

D

5 14 3 2

PROJECT NORTH

DR

AW

N B

Y:

N

AV

AL

S U

RF

AC

E W

AR

FA

RE

C

EN

TE

R

PH

IL

AD

EL

PH

IA

, P

A N

SW

C

P D

IN

FR

A

ST

R U

C

TU

R E

A C

Q U

IS

IT

IO

N

S U

P P

O R

T

DE

SI

GN

ED

B

Y:

DW

G N

AM

E:

SH

EE

T

SI

ZE

CO

DE

SA

VE

D

AT

E:

SC

AL

E:

PL

O

T

DA

TE

N O

TE

S:

of 04

BU

IL

DI

N

G

H

FL

O O

R

E

XT

ER

IO

R

FU

EL

S

TO

RA

GE

F

AC

IL

IT

Y

FU

EL

P

U M

P

CO

N

TR

O

LL

ER

S

YS

TE

M R

EP

AI

RS

(P

HA

SE

AR

CH

D (2

4-in

. x

4-in

REVISION TABLE

SYM DESCRIPTION DATE APPR

FINAL DRAWING 03/21/22

RM

S

RM

S

ST

AT

EM

EN

T O

F W

O

RK

A

TT

AC

HM

EN

T

(1

)GENERAL NOTES:

1. DRAWINGS DO NOT INDICATE ALL REQUIRED FEATURES OF INSTALLED MATERIAL. REFER TO

CONTRACT STATEMENT OF WORK FOR ADDITIONAL REQUIREMENTS AND DETAILED

SPECIFICATIONS. REFER TO SOW ATTACHMENTS FOR DETAILS ON CP-FOPV.

2. ALL ELECTRICAL WORK AND MATERIAL SHALL CONFORM TO NATIONAL FIRE PROTECTION

ASSOCIATION (NFPA) 70 NATIONAL ELECTRIC CODE (NEC) 2020 EDITION. ALL WORK AND MATERIAL

SHALL BE IN ACCORDANCE WITH THE NEC FOR DIVISION 1 CLASS 1 GROUP D HAZARDOUS

LOCATIONS IN ALL EXTERIOR LOCATIONS. ALL WIRING SHALL BE PROVIDED IN RIGID METALLIC CONDUIT (RMC) IN EXTERIOR LOCATIONS AND ELECTRICAL METALLIC CONDUIT (EMT) IN INTERIOR

LOCATIONS UNLESS OTHERWISE NOTED.

3. ALL MATERIAL AND EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S

WRITTEN INSTRUCTIONS. RECOMMENDATIONS NECESSARY FOR A COMPLETE AND USEABLE

SYSTEM SHALL BE IMPLEMENTED AT NO ADDITIONAL COST TO THE GOVERNMENT.

4. LABEL EACH MOTOR OPERATED VALVE WITH THE POWER SOURCE PANEL NAME, PANEL LOCATION, AND CIRCUIT NUMBER. LABELING SHALL BE WEATHER AND UV RESISTANT.

5. ALL CONTROL AND COMMUNICATION WIRES SHALL BE LABELED AT EACH TERMINATION POINT AND WHERE SPLICED. LABELING SHALL CONFORM TO THE NOTATIONS ON THE CONTRACTOR PROVIDED

WIRING SCHEMATIC.

6. STRANDED WIRING TERMINATIONS SHALL USE CRIMP-TYPE OR SIMILAR TERMINALS COMPATIBLE WITH EQUIPMENT TERMINATION POINTS AT ALL LOCATIONS. TERMINALS SHALL BE LISTED WITH THE UNDERWRITER'S LABORATORY (UL). TERMINALS SHALL BE USED FOR THE WIRE SIZE OF WHICH

THEY ARE LISTED FOR.

7. PROVIDE EACH NEW INSTRUMENT AND ACTUATOR WITH A DEDICATED WEATHER PROOF STORAGE CANISTER SUITABLE FOR STORAGE OF WIRING DIAGRAMS AND OWNER'S MANUALS AND SIZED TO

HOLD THE MANUALS AND DRAWINGS. FASTEN THE CANISTER ADJACENT TO THE INSTRUMENT OR

ACTUATOR USING AN APPROVED UV RESISTANT AND DURABLE FASTENER SYSTEM.

8. CALIBRATE INSTRUMENTS AS RECOMMENDED BY THE MANUFACTURER. PROVIDE PROGRAMMING

AND GRAPHICAL INTERFACE FOR NEW MONITORING POINTS.

C5 MOTOR OPERATED VALVE CONTROLS

C3 INSTRUMENT TRANSMITTERS

C CLOSE

CB CIRCUIT BREAKER

CP CONTROL PANEL

CR CURRENT RELAY

LIT LEVEL INSTRUMENT TRANSMITTER

FE FLOW ELEMENT

FIT FLOW INSTRUMENT TRANSMITTER

FOPV FUEL OIL PUMPS AND VALVES

LSC LIMIT SWITCH (CLOSE)

LSO LIMIT SWITCH (OPEN)

MOV MOTOR OPERATED VALVE

O OPEN

S STOP

SOP SEQUENCE OF OPERATION

SOW STATEMENT OF WORK

SPDT SINGLE POLE DOUBLE THROW

SPST SINGLE POLE SINGLE THROW

VAC VOLTS ALTERNATING CURRENT

ZIT POSITION INDICATING TRANSMITTER

NEW WORK KEYNOTES:

1. PROVIDE VALVE ACTUATOR WITH INTEGRATED POWER DISCONNECT. DISCONNECT MAY BE IN THE

FORM OF AN INTEGRATED CIRCUIT BREAKER.

2. PROVIDE VALVE ACTUATOR WITH SELF-POWERED MOTOR CONTROL CIRCUIT.

3. PROVIDE VALVE ACTUATOR WITH LOCAL-OFF-REMOTE SELECTOR SWITCH.

4. PROVIDE VALVE ACTUATOR WITH REVERSING CONTACTOR WITH MECHANICAL AND ELECTRICAL

INTERLOCKS FOR THE OPEN AND CLOSE COILS.

5. PROVIDE MOTOR WITH OVERLOAD PROTECTION.

6. PROVIDE REMOTE OPEN-CLOSE-STOP CIRCUITS FOR VALVE OPERATION FROM PANEL CP-FOPV.

PROVIDE SPST CURRENT RELAYS IN CP-FOPV FOR REMOTE START, STOP, AND CLOSE CONTROL

OF EACH VALVE ACTUATOR. PROVIDE WITH DIN RAIL MOUNTING ACCESSORIES AS REQUIRED.

SPDT RELAYS ARE ACCEPTABLE PROVIDED ONLY THE NC OR NO CONTACT TERMINAL IS USED TO COMPLETE THE CIRCUIT. CURRENT RELAYS SHALL BE RATED FOR 120VAC ON THE COIL AND AS

REQUIRED BY THE VALVE ACTUATOR MANUFACTURER ON THE SWITCHED CIRCUIT. PROVIDE

WIRING BETWEEN EACH VALVE ACTUATOR AND THE CP-FOPV PANEL LOCATED IN BUILDING 77H.

SIZE CONDUCTORS TO THE VALVE ACTUATOR AS REQUIRED BY THE NEC AND MANUFACTURER.

VOLTAGE DROP SHALL BE CONSIDERED AND MAY REQUIRE LARGER CONDUCTORS THAN

RECOMMENDED BY THE MANUFACTURER.

7. PROVIDE INSTRUMENT WIRING AS RECOMMENDED OR REQUIRED BY THE MANUFACTURER. ALL

WIRING SHALL BE SHIELDED. GROUND SHIELDING IN PANEL CP-FOPV. THE INSTRUMENT-SIDE

SHIELDING SHALL BE ELECTRICALLY INSULATED TO PREVENT TRANSMISSION OF

ELECTROMAGNETIC INTERFERENCE. WHERE VOLTAGE DROP EXCEEDS MANUFACTURER

REQUIREMENTS, INCREASE CONDUCTOR SIZE.

8. EXISTING ALLEN BRADLEY COMPACT 1769-IF4 ANALOG INPUT MODULE. SPARES AVAILABLE FOR

INSTRUMENT USE. MODULE DOES NOT PROVIDE LOOP POWER FOR ANALOG INPUTS.

TRANSMITTERS MUST PROVIDE POWER FOR LOOP OR A POWER SUPPLY MUST BE INCORPORATED

INTO THE INSTRUMENT LOOP BY THE CONTRACTOR. CURRENT TERMINALS HAVE AN INPUT

IMPEDANCE OF 250 OHMS AND OPERATE NORMALLY FROM 0-20 mA AND 4-20 mA.

9. PROVIDE MOV WITH POSITION INDICATING TRANSMITTER/CIRCUIT FOR FEEDBACK ON VALVE

POSITION (TYP. OF 4).

10. PROVIDE FLOW METER WITH FLOW INSTRUMENT TRANSMITTER. PROVIDE POWER AS REQUIRED

FOR INSTRUMENT AND TRANSMITTER.

11. PROVIDE 120 VAC POWER FROM CONTROL PANEL CP-FOPV.

7 8

MEP-501

TABLE 1 - MOV MOTOR SCHEDULE

MIN.

HORSEPOWER VOLTAGE PHASE FREQUENCY MAX. CURRENT SEC/90° (MIN/MAX)

12 HP 120 VAC 1-PHASE 60 HZ 5 AMPS 4.0-7.0

NOTES: (1) PROVIDE EXPLOSION PROOF ENCLOSURES (2) MOV MOTOR SCHEDULE APPLIES TO

MOV ACTUATORS TF-E5, TF-E8, YV-1B, AND YV-4B.

ABBREVIATIONS:

TABLE 2 - ALARM INTERLOCK SCHEDULE

INSTRUMENT

TRANSMITTER ALARM SET POINT AFFECTED EQUIP ALARM INTERLOCK

LIT 1 HIGH HIGH LEVEL TANK T-4 171,500 GALLONS PUMP P-6 AND MOV YV-1B IN REMOTE MODE: (1) DE-ENERGIZE PUMP; (2) CLOSE VALVE.

LIT 4 HIGH HIGH LEVEL TANK T-5 171,500 GALLONS PUMP P-6 AND MOV YV-4B IN REMOTE MODE: (1) DE-ENERGIZE PUMP; (2) CLOSE VALVE.

LIT 1 LOW LEVEL TANK T-4 17,500 GALLONS PUMPS 3A, 7A, & 7B AND MOV

TF-E5

IN REMOTE MODE: (1) DE-ENERGIZE PUMPS; (2) CLOSE VALVE.

LIT 4 LOW LEVEL TANK T-5 17,500 GALLONS PUMPS 3A, 7A, & 7B AND MOV

TF-E8

IN REMOTE MODE: (1) DE-ENERGIZE PUMPS; (2) CLOSE VALVE.

FIT 22 LOW FLOW FE 22 17.5 GPM PUMPS 3A, 7A, & 7B

IN REMOTE MODE: (1) DE-ENERGIZE PUMPS IF FLOW IS EQUAL TO OR LESS THAN

SET POINT FOR MORE THAN FIVE (5) SECONDS WHILE PUMP 3A, 7A, 7B, OR ANY

COMBINATION THEREOF ARE RUNNING.

M O

TO

R

IN

ST

RU

M

EN

T

DE

TA

IL

S

N /A

VALVE SEQUENCE OF OPERATION:

IN "OFF" POSITION

1. VALVE OPERATED BY HAND-OPERATING MECHANISM ONLY.

IN "REMOTE (AUTO)" POSITION

1. IF REMOTE "OPEN" RELAY CIRCUIT IS COMPLETED, ASSOCIATED VALVE OPENS UNTIL (A) LIMIT

SWITCH OPEN OR TORQUE SWITCH IS ENGAGED OR (B) UNTIL THE LOCAL STOP PUSHBUTTON IS

PRESSED OR (C) REMOTE "STOP" RELAY CIRCUIT IS COMPLETED.

2. IF REMOTE "CLOSE" RELAY CIRCUIT IS COMPLETED, ASSOCIATED VALVE CLOSES (A) UNTIL LIMIT SWITCH CLOSE OR TORQUE SWITCH IS ENGAGED OR (B) UNTIL THE LOCAL STOP PUSHBUTTON IS

PRESSED OR (C) REMOTE "STOP" RELAY CIRCUIT IS COMPLETED.

3. WHEN ALARM CONDITION IN TABLE 2 IS PRESENT, PERFORM ASSOCIATED ALARM INTERLOCK

FUNCTION FOR APPLICABLE VALVE(S).

IN "LOCAL (HAND)" POSITION

1. WHEN "OPEN" PUSHBUTTON IS PRESSED, VALVE OPENS UNTIL (A) LIMIT SWITCH OPEN OR TORQUE

SWITCH IS ENGAGED OR (B) THE LOCAL STOP PUSHBUTTON IS PRESSED.

2. WHEN "CLOSE" PUSHBUTTON IS PRESSED, VALVE CLOSES UNTIL (A) LIMIT SWITCH CLOSE OR

TORQUE SWITCH IS ENGAGED OR (B) THE LOCAL STOP PUSHBUTTON IS PRESSED.

3. WHEN "STOP" PUSHBUTTON IS PRESSED, VALVE OPERATION IS STOPPED IN ITS CURRENT

POSITION.

GENERAL NOTES:

1. PHOTOGRAPHS ARE REPRESENTATIVE AND DO NOT REFLECT ALL CONDITIONS AT THE

WORK SITE.

2. PHOTOGRAPHY AND VIDEO CAPTURING ARE STRICTLY PROHIBITED. PHOTOGRAPHS AND

VIDEOS MAY ONLY BE CAPTURED AND/OR RECORDED BY A GOVERNMENT

REPRESENTATIVE USING A GOVERNMENT-ISSUED CAMERA RECORDING DEVICE.

D5 PHOTOGRAPH 1

NEW WORK KEYNOTES:

1. FUEL STORAGE TANK T-4 (175,000 GALLON CAPACITY).

2. STEEL BRIDGE SUPPORTING CONDUIT AND PIPING BETWEEN BUILDING 77H AND THE

EXTERIOR FUEL STORAGE FACILITY.

3. FUEL STORAGE TANK T-5 (175,000 GALLON CAPACITY).

4. APPROXIMATE LOCATION OF FUTURE ULTRASONIC FLOW METER.

5. EXISTING TEMPERATURE INSTRUMENT TRANSMITTER REQUIRING CALIBRATION

(TYPICAL OF TWO).

6. MOTOR OPERATED VALVE WITH ELECTRIC ACTUATOR ON 6-INCH SUPPLY FROM TANKS

T-4 AND T-5. TYPICAL OF TWO FOR TF-E5 AND TF-E8.

7. EXISTING INOPERABLE FLOW METER. REPLACE FLOW METER WITH STAINLESS STEEL

FLANGED SPOOL. CONDUIT MAY BE REPURPOSED FOR NEW ULTRASONIC FLOW METER.

8. MOTOR OPERATED VALVE WITH ELECTRIC ACTUATOR ON 6-INCH FILL TO TANK T-4.

TYPICAL OF TWO FOR YV-1B AND YV-4B.

9. BUILDING 77H.

10. CONDUIT AND PIPING ENTERING BUILDING 77H.

11. FUEL OIL CONTROL PANEL FOR PUMPS AND VALVES (CP-FOPV).

12. EXISTING COUPLING FOR VALVE ACTUATOR DRIVES.

MEP-101 D4 PHOTOGRAPH 2

D3 PHOTOGRAPH 3 D2 PHOTOGRAPH 4

6 6

B5 PHOTOGRAPH 5 B4 PHOTOGRAPH 6

B3 PHOTOGRAPH 7 B2 PHOTOGRAPH 8

A5 PHOTOGRAPH 9 A4 PHOTOGRAPH 10

AUTHORIZED FOR PUBLIC RELEASE; DISTRIBUTION UNLIMITED.

15 4 3 2

A

B

C

D

5 14 3 2

PROJECT NORTH

DR

AW

N B

Y:

N

AV

AL

S U

RF

AC

E W

AR

FA

RE

C

EN

TE

R

PH

IL

AD

EL

PH

IA

, P

A N

SW

C

P D

IN

FR

A

ST

R U

C

TU

R E

A C

Q U

IS

IT

IO

N

S U

P P

O R

T

DE

SI

GN

ED

B

Y:

DW

G N

AM

E:

SH

EE

T

SI

ZE

CO

DE

SA

VE

D

AT

E:

SC

AL

E:

PL

O

T

DA

TE

N O

TE

S:

of 04

BU

IL

DI

N

G

H

FL

O O

R

E

XT

ER

IO

R

FU

EL

S

TO

RA

GE

F

AC

IL

IT

Y

FU

EL

P

U M

P

CO

N

TR

O

LL

ER

S

YS

TE

M R

EP

AI

RS

(P

HA

SE

AR

CH

D (2

4-in

. x

4-in

REVISION TABLE

SYM DESCRIPTION DATE APPR

FINAL DRAWING 03/21/22

RM

S

RM

S

ST

AT

EM

EN

T O

F W

O

RK

A

TT

AC

HM

EN

T

(1

MEP-901

MEP-101 MEP-101 MEP-101

MEP-101MEP-101MEP-101MEP-101

MEP-101 MEP-101

PH

O

TO

GR

AP

HS

N /A

PRA ID #NSWCPD-002326

File details come from the government source that posted it. Updated .