SOW APPENDIX 7 - Bldg 2324 Photos.pdf
PDF 3 MB Posted
- Attached to
- General Facility Repairs-Patch Barracks Federal contract opportunity
- Solicitation number
- W912DY21R0037
About this file
This request for proposal is for general facility repairs to Building 2324 Patch Barracks in Stuttgart, Germany. The Department of the Army Corps of Engineers Engineering Support Center Huntsville is soliciting proposals for a firm fixed price design-build contract to provide repairs to existing areas of the building, including replacing modular VCT tile floors, evaluating and leveling floors beneath cracked VCT, and replacing workstations, chairs, and typical ceiling cassette air conditioning units throughout the facility. Proposals are due by the date specified in the attached request for proposal documents. The work must be completed under NAICS code 236220 for commercial and institutional building construction.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| RFP Amendment 0002.pdf | ||
| RFP Amendment P00001.pdf | ||
| SOW APPENDIX 10 - FFE Design Submittal Requirements Matrix.pdf | ||
| SOW APPENDIX 12 - Bldg 2324 HVAC Survey Report.pdf | ||
| RFP W912DY21R0037.pdf | ||
| Division 01 Specs.pdf | ||
| SOW APPENDIX 13 - Bldg 2324 Drawings.pdf | ||
| SOW APPENDIX 9 - Bldg 2324 Floor Plan and New Offices.pdf | ||
| SOW APPENDIX 11 - Construction Security Plan_Bldg 2324.pdf | ||
| SOW APPENDIX 8 - Bldg 2324 New Offices Concept.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
APPENDIX 7 – Photos of Facility
Room 119
Break Room, Room number 123
Break Room, Room number 123
First floor hallway, west facing, outside Room 123
First floor hallway, east facing, outside Room 122
Ceiling Cassette for DAIKIN split unit. Typical throughout facility. Air recirculation unit only. Air supply and return have separate ducts and registers.
24" x 24" fluorescent light fixture. Typical throughout facility.
Typical workstation
Conference room configuration, Room 107
Typical existing workstation Herman Miller Aeron chair. Replace in‐kind.
Modular VCT tile floor in hallways to be replaced. Cracks denote uneven floor beneath VCT.
Floors will require evaluation and levelling prior to new flooring being installed.
First Floor Hallway, west facing, outside Room 109