MANUFACTURED HOUSING UNIT

FEDERAL EMERGENCY MANAGEMENT AGENCY

NextGen Express Unit

(Furnace/AC System)

June 28, 2019

VERSION 1

COVER PAGE

TITLE:

Scale: NTS

6/28/2019FEMA Manufactured Housing Units

Federal Emergency Management Agency

DRAWING NO.

Express MHU (Furnace)

8F-1.1

. Jun 28, 2019

INDEX

Dwg. No. Title

8F-1.1 Cover Page

8F-1.2 Index

8F-1.3 General Notes

8F-2 Floor Plan

8F-3 Door and Window Schedule

8F-4.1 Furniture Plan

8F-4.2 Installed Furniture Layout

8F-5 UFAS Layout

8F-6 Electrical Plan

8F-7 Water Lines

8F-8 Drain Lines

8F-9 HVAC Design and Overhead Duct Layout

8F-10 Elevations

8F-11.1 Chassis

8F-11.2 Chassis Details

8F-12 Floor Framing Layout

8F-13 Floor Decking Layout

8F-14 Interior Wall/Back Panel Layout

8F-15 Reserved

8F-16.1-.15 Interior Walls

8F-17.1&.2 End Wall Framing and Interior Sheathing

8F-18.1 Shearwall Framing and Exterior Sheathing

8F-18.2 Reserved

8F-19 Front Door Sidewall

8F-20 Back Door Sidewall

8F-21 Roof Framing Layout

8F-22 Roof Sheathing Layout

8F-23 Roof Overhang Detail

8F-24.1 Kitchen Elevations

8F-24.2 Bathroom Elevations

8F-24.3 Reserved

8F-25.1 Sprinkler System Layout

8F-25.2 Sprinkler System Details

8F-26 Ship Loose Layout

8F-27 Transit Protection Details

8F-28 Transportation Lighting

8F-29.1 Tie Down System

8F-29.2 Exterior Wall Tie Down Details

8F-30 Double Stack Pier Layout & Details

APPENDIX A

Dwg. No. Title

A-1 Cover Page

A-2 Miscellaneous Height Requirement Details

A-3 Miscellaneous Height Requirement Details

A-4 Kitchen Sink Access Panel Details

A-10 Door Details

A -11 Door Flashing Details

A-20 Window Details

A-21 Window Flashing Details

A-30 Miscellaneous Details

A-31 Miscellaneous Details

A-32 Miscellaneous Details

A-40 Chassis AC Mount Details

A-50 TPS Closet Plan and Notes (14' Wide)

A-51 TPS Closet Elevations (14' Wide)

A-52 TPS Closet Details (14' Wide)

A-60 Sprinkler Riser Plan and Detail (8' Wide)

INDEX

TITLE:

Scale: NTS

6/28/2019FEMA Manufactured Housing Units

Federal Emergency Management Agency

DRAWING NO.

Express MHU (Furnace)

8F-1.2

MANUFACTURED HOUSING UNIT

Federal Emergency Management Agency

GENERAL NOTES

CODES AND STANDARDS

Manufactured Home Construction and Safety Standards 24 CFR 3280

Manufactured Home Procedural and Enforcement Regulations 24 CFR 3282

Uniform Federal Accessibility Standards (UFAS)

Standard for the installation of Sprinkler Systems in Manufactured Homes (NFPA 13D)

Referenced 2005 National Electrical Code (NFPA 70) Articles as Incorporated in HUD 24 CFR 3280

STRUCTURAL LOADS

Floor Live Load 40 PSF

Floor Dead Load 10 PSF

Roof Live Load 40 PSF

Roof Dead Load 10 PSF

Comply with Wind Zone 3 Requirements of 24 CFR 3280

Wood Roof Diaphragm

Wall Height: 7'-6"

GENERAL NOTES

TITLE:

Scale: NTS

Date: 6/28/2019FEMA Manufactured Housing Units

Federal Emergency Management Agency

DRAWING NO.

Express MHU (Furnace)

8F-1.3

WD

REFER

BATH

70.1 SQ. FT.

KITCHEN

LIVING/DINING AREA

150.0 SQ. FT.

BEDROOM

9'-2"27'-1"7'-7"

9'-6"

14'-3

2"

48'-0"

22'-8

4"29'-2"

36'-10

2"

2'-1

2" 5'-0

2"12'-1"6'-11

2"

29'-7

2"

9'-6"

22'-3

4"

17'-3"

41'-5

2"

10'-6"

31'-10"

5'-11

2"

W/H

4"

4" 2'-4

2"

14'-10"

36'-10

2"

3'-2" 2'-10" 2'-6"

2'-10"

4"

39'-6

2"

4"

3060E

UTILITY

8" 25

2"

2"

5"

2" 3"

2"

RANGE HOOD

RANGE

FIXED PANE

PANTRY

EXTERIOR

A/C

UNIT

SIDEWALL HEIGHT = 90"

TRUSS VERTICAL PROJECTION = 9

2"

SHEARWALLS - WIND ZONE 3

NO. LENGTH PLF

1 96" 637

2 96" 637

LIGHT & VENT SCHEDULE

ROOM TITLE AREA REQ'D LIGHT REQ'D VENT

LIVING/DINING

AREA

150 S.F. 12.0 S.F. 6.0 S.F.

BEDROOM 70.1 S.F. 5.61 S.F. 2.81 S.F.

34"

9'-2"

F

SHEAR WALLS WIND ZONE 3

DESIGNATES A 2X4 INTERIOR WALL

DESIGNATES A 2X6 INTERIOR WALL

x

R

A

G

20'-1

4"

18"

4" 24"

FLOOR PLAN

TITLE:

Scale: 3/16" = 1'-0"

Date: 6/28/2019FEMA Manufactured Housing Units

Federal Emergency Management Agency

DRAWING NO.

Express MHU (Furnace)

8F-2

BATH

KITCHEN

LIVING/DINING AREA

BEDROOM

W/H

UTILITY

D1

D2

D3

W1

W2

D3

W1

W1

PANTRY

MARK

D1

D2

D3

WIDTH

3'-0"

3'-0"

2'-0"

HEIGHT

6'-8"

6'-8"

6'-8"

THICKNESS

1-3/8"

1-3/8"

1-3/8"

TYPE

Outswing Door

Hallway Doors

Closet & W/H Doors *

DOOR SCHEDULE

Door Notes

1. Exterior doors shall meet 24 CFR 3280.405 requirements and shall comply with Wind Zone 3 requirements.

2. All exterior doors shall be insulated fiberglass or steel with a maximum U-Value of 0.33.

3. All doors shall have lever type handles in compliance with UFAS 4.13.9.

4. For additional information on exterior and interior doors see FEMA specifications and Appendix A.

5. Return air grills shall be installed above doors unless the grill will be blocked by the sprinkler system and then may be installed in the door or wall.

6. Door stops shall be installed at all interior and wardrobe doors. Door stops may be installed on the door or the floor baseboard. Door stop finish to match interior hardware finish.

7. All bathroom and bedroom doors shall have a privacy lock. The lock mechanism shall be the button type

(UFAS 4.13.9) and located on the inside of the bathroom or bedroom.

8. The water heater compartment side of the water heater access door shall be covered with minimum 5/16 inch thick gypsum board.

9. The closet door shall be equipped with a passage lockset.

MARK

W1

W2

WIDTH

2'-6"

2'-6"

HEIGHT

5'-0"

2'-3"

TYPE

Single Hung Window

Fixed Pane Window

WINDOW SCHEDULE

Window Notes

1. Windows shall meet 24 CFR 3280.403 and 3280.404 requirements and shall comply with Wind Zone 3 requirements.

2. Windows shall be double paned, low E with vinyl frame. Windows shall have a minimum SHGC of 0.30 and a maximum U-Value of 0.36.

3. Windows shall have a design pressure rating of 58.

4. Windows shall have screens.

TOTAL EXTERIOR DOOR AREA: 43.28 SQ. FT.

TOTAL WINDOW AREA: 44.27 SQ. FT.

D1

D2

EXTERIOR

A/C

UNIT

F

D4 1'-6" 6'-8" 1-3/8" Sprinkler Riser Access Door

D4

DOOR AND WINDOW SCHEDULE

TITLE:

Scale: 3/16" = 1'-0"

Date: 6/28/2019FEMA Manufactured Housing Units

Federal Emergency Management Agency

DRAWING NO.

Express MHU (Furnace)

8F-3

W/H

DINING

TABLE

LOVE SEAT

C O

F F

E E

T A

B L

E

KITCHEN

ITEM SPECIFICATIONS

REFRIGERATOR

30" W x32.5" D, 18 CU. FT.

RANGE *

30" W x 28" D (MAX)

MICROWAVE

19" D MIN., 1.2 CU. FT.

BATHROOM

ITEM SPECIFICATIONS

MEDICINE CABINET 15" W x 25" H x 3" D

SHOWER

36" W x 36" L, FIBERGLASS

WC SEE FEMA SPEC

WATER HEATER 40 GALLONS

BEDROOM

ITEM SPECIFICATIONS

FULL BED 75" L x 54" W

DRESSER

(4 DRAWER)

30" W x 18" D x 48" H

DINING ROOM

ITEM SPECIFICATIONS

DINING TABLE 36" L x 24" W

DINING CHAIR 2 IDENTICAL CHAIRS

PANTRY 24" W x 12" D

LIVING ROOM

ITEM SPECIFICATIONS

LOVE SEAT 44" W x 24" D

COFFEE TABLE 30" W x 18" D

F

BATH

KITCHEN

LIVING/DINING AREA

BEDROOM

UTILITY

PANTRY

EXTERIOR

A/C

UNIT

DRESSER

DEHUMIDIFIER PROVIDED BY FEMA

TITLE:

FEMA Manufactured Housing Units

Federal Emergency Management Agency

COMPANY: VERSION:

FURNITURE PLAN

Scale: 3/16" = 1'-0"

Date: 6/28/2019

DRAWING NO.

Express MHU (Furnace)

8F-4.1

Furniture And Appliances Notes

1. All refrigerators shall be ENERGY STAR qualified and have the ENERGY STAR label affixed to the appliance when delivered with the MHU.

2. Range and oven controls shall be at the front of the appliance.

3. The range hood shall extend the width of the range and a minimum of 3" beyond the front face of the overhead cabinet.

4. The range hood vent opening at the cap shall be screened with a corrosion-resistant, non-combustible wire mesh with

1/4" openings or equivalent.

5. A shower rod and new, neutral-colored plastic shower curtain (71" L x 71" H) with full set of rings/hooks shall be provided for all shower/bath fixtures.

6. Two (2) metal, rust-resistant, wall-mounted towel bars with chrome finish shall be installed in each bathroom.

7. Metal, rust-resistant, toilet-paper holder with chrome finish shall be installed in each bathroom.

8. Mattresses shall be innerspring, non-latex (can be polyester, cotton, or blend ticking and wadding) new mattresses with medium firmness and 9" to 11" height.

9. The range hood vent shall be vented through the exterior wall.

* General Notes

1. Range depth (Back of range to front edge of oven handle depth cannot exceed 28").

FEMA SUPPLIED

DEHUMIDIFIER

TABLE

LOVE SEAT

C O

F F

E E

T A

B L

E

F

BATH

KITCHEN

LIVING/DINING AREA

BEDROOM

UTILITY

PANTRY

EXTERIOR

A/C

UNIT

DRESSER

TITLE:

FEMA Manufactured Housing Units

Federal Emergency Management Agency

COMPANY: VERSION:

INSTALLED FURNITURE LAYOUT

Scale: 3/16" = 1'-0"

Date: 6/28/2019

DRAWING NO.

Express MHU (Furnace)

8F-4.2

General Notes

1. Vendor to tape a copy of this drawing to the outside of the water heater compartment door.

TABLE

LOVE SEAT

C O

F F

E E

T A

B L

E

BEDROOM LIVING/DINING AREA KITCHEN

UTILITY

BATH

34" 18"

6 5 2

4 3 9 10

F

DRESSER

UFAS MANEUVERING CLEARANCES AT DOORS AND TURNING SPACE CONFIGURATION LAYOUT

24"24

4"

W/H

DINING

TABLE

LOVE SEAT

C O

F F

E E

T A

B L

E

BEDROOM LIVING/DINING AREA KITCHEN

UTILITY

BATH

F

DRESSER

UFAS CLEAR FLOOR SPACE LAYOUT

SEE NOTE 4

SEE NOTE 4

TITLE:

FEMA Manufactured Housing Units

Federal Emergency Management Agency

COMPANY: VERSION:

UFAS LAYOUT

Scale: 1/8" = 1'-0"

Date: 6/28/2019

DRAWING NO.

Express MHU (Furnace)

8F-5

UFAS Maneuvering Clearances at Doors and Egress Chart

Location UFAS Section and/or Figure References

Exterior Doors

1. Front Door – Living Room/Kitchen to Front Door 4.13.6 – Figure b – Push side

2. Front Door – Living Room/Bedroom to Front Door 4.13.6 – Figure b – Push side

3. Rear Door – Hall to Rear Door 4.13.6 – Figure b – Push side

4. Rear Door – Kitchen to Rear Door 4.13.6 – Figure c – Push side

Bedroom

5. Hallway to Bedroom 4.13.6 – Figure a – Push side – See Note 1

6. Bedroom to Hallway 4.13.6 – Figure a – Pull side

7. Bedroom to Closet 4.13.6 – Figure c – Pull side

8. Turning Space Configuration 4.2.3 – Figure a – 60" Diameter Space

Location UFAS Section and/or Figure References

Bath 1

9 Hall to Bath 4.13.6 – Figure a – Pull side

10. Bath to Hallway 4.13.6 – Figure a – Push side – See Note 1

11. Turning Space Configuration 4.2.3 – Figure b – T-Shaped Space

12. Lavatory Clear Floor Space 4.19.3 – 30” x 48”

13. Shower Clear Floor Space 4.21.2 – Figure 35(a) - 36” x 48”

14. Toilet Clear Floor Space 4.16.2 - Figure 28 – 56” x 60”

Living Room

15. Turning Space Configuration 4.2.3 – Figure a – 60" Diameter Space

Kitchen

16. Turning Space Configuration 4.2.3 – Figure b – T-Shaped Space

17. Range Clear Floor Space 4.34.6.2 – 30” x 48”

18. Sink Clear Floor Space 4.34.6.5(7) – 30” x 48”

19. Counter Work Surface Clear Floor Space 4.34.6.2 – 30” x 48”

20. Refrigerator Clear Floor Space 4.34.6.2 – 30” x 48”

Notes

1. Door does not have closer.

2. The minimum clear width for a single wheelchair continuous path is 36” (UFAS 4.2.1).

3. All appliances shall be UFAS Compliant.

4. 50% of shelf space shall be below 54" reach range (UFAS 4.25.3).

5. The ADA compliant range cannot be deeper than 28” (From rear wall to the furthest extend of the range handle .

6. The Range electrical receptacle must be recessed.

NOAA

GFCI-WP

S

S

SA

G F

C I

FE

SS

GFCI-WP

WP

WP

SSS

H.T. GFCI

RH 16

SS

REFR

7-GFCI

GFCI

S

G F

C I

G F

C I

G F

C I

TV

TV

SS

Service Entrance J-Box

J

G F

C I

F

SA

T

44" AFF 18" AFF TO RECEPTACLE SCREW

SINGLE OUTLET RECEPTACLE

FOR REFRIGERATOR

WP

SEE

GENERAL

NOTE 2

TITLE:

FEMA Manufactured Housing Units

Federal Emergency Management Agency

COMPANY:

Cir. Purpose Type Wire Size Amps Pole

Bedroom 1 14-2 15 1

2 NA - -

3 NA - -

4 Kitchen 20 1

5 Kitchen 1

6 Ext. Recep 1

7 Washer 1

8 Dryer 30 2

9 Electric Range

10 Water Heater

11 A/C

12 Smoke Detectors 15 1

13 Furnace

GFCI

12-2

10-3

Per MFR. Specs.

14-3

20GFCI 12-2

20GFCI 12-2

20GFCI 12-2

Per MFR. Specs.

Per MFR. Specs.

14 Living Room 15 114-2

16 Lights/Recep 15 114-2

17 Dining Room 20 114-2

18 Refrigerator 15 114-2

Per MFR. Specs.

19 Bath Receps / Heat Tape 20 114-2

GFCI

GFCI

J

WP

Sym. Description

110 volt duplex recep-wall mounted

110 volt duplex-GFCI protected recept

220 volt recept-wall mounted

Light Fixture - Ceiling Mounted

Light Fixture - Wall mounted

Exhaust fan - Light Combo

Distribution panel board - 200 Amp

Exterior light fixture - weather proof

Junction Box

TV

FE

S

S

NOAA

T

Smoke Alarm with strobe light- wired in series

Telephone Recept

TV Outlet

Fire Extinguisher

Switch

Switch - Three Way

Outlet for NOAA Weather radio

Thermostat

SA

Sym. Description

ELECTRICAL PLAN

Scale: 3/16" = 1'-0"

DRAWING NO.

Express MHU (Furnace)

8F-6

Electrical and Lighting Notes

1. The highest breaker in the panel box should be 48” high. Panel box bottom must be at least 24” from the floor.

2. The light bulbs shall be LED, equivalent to 60-watt incandescent bulbs, min. 800 lumens, white in color, between 2,700 K and 4,100 K.

3. No glass shall be used in any of the lighting globes.

4. The exterior lights shall be stored in the refrigerator during transport.

5. Interconnected smoke alarms shall utilize the home’s primary power source and shall have battery backup.

6. The centerline of the switches and the top of thermostat must be installed at no more than 48” above the finished floor.

7. Electrical outlets must be no lower than 18" above the floor to the center of the receptacle screw.

8. The junction box for the telephone and cable shall be located within 4’ of the road side rear of the MHU.

9. Electric wiring may be done either through the floor or the ceiling.

10. The exterior service entrance junction box shall be rated NEMA 3 and minimum of 12” x 12” x 4”.

11. Service entrance junction box shall be mounted to floor joist between the I-beam and sidewall.

12. Service entrance junction box to be located within 10’ on the curb side rear of MHU.

13. The wiring from the service entrance junction box to service panel to be in seal-tight conduit.

14. Bathroom exhaust fan with light to be 75 cfm with an integrated timer to allow fan to operate sixty minutes minimum prior to turning off.

15. Kitchen range hood exhaust fan with a white light shall be a minimum 100 cfm exhaust fan, with separate switches.

16. Bathroom and kitchen exhaust fans shall vent directly to the outside.

17. Ceiling lights shall have 2 LED bulbs.

18. The bathroom vanity light shall be wall mounted with 3 LED bulbs.

19. The circuit breaker(s) providing power to the TPS unit shall be equipped with a UL-listed locking device that can secure the breaker(s) in the ON position. Devices shall be installed set to the ON position and shall be equipped with an appropriate lock that fits inside the panel board.

20. Kitchen countertop receptacles and switches must be furred out to be 24" (max) from front edge of countertop and no more than 44" to the top of the switches or receptacles above finished floor.

TPS System

General Notes

1. The range electrical receptacle must be flush mount.

2. Circuit #15 has an external TPS electrical connection with a female IEC 60 309-2 international pin and sleeve connection. The external TPS electrical connection shall be located 24" in from the road side of the MHU and 12" up from the bottom of the exterior siding.

30 28-3

Date: 6/28/2019

LEGEND

CUT OFF VALVE LOCATION

3/4" LINE (HOT)

1/2" LINE (HOT)

3/4" LINE (COLD)

1/2" LINE (COLD)

ADJACENT PIPE SIZES.

FITTING SIZES TO CORRESPOND TO

ALL SIZING OF PIPE + OR -, MUST

MEET OR EXCEED ANY APPLICABLE

2)

CODES.

1)

NOTES:

SInk

W/H

Washer

Lav

Stool

Shower

Inlet

Master Shutoff

DRAIN

Hose Bib

LOW POINT DRAIN IN WATER

LINES WITH SHUT OFF VALVES

Federal Emergency Management Agency

COMPANY:

Water Supply System Notes

1. The water supply lines shall be Cross-linked polyethylene (PEX) or chlorinated polyvinyl chlorine (CPVC) and comply with the requirements of 24 CFR 3280.

2. All water lines shall be 1/2” unless noted.

3. The water supply inlet shall be 3/4” and have a brass quarter turn ball valve.

4. The water supply inlet shall extend not more than 6” below the bottom board.

5. The water supply inlet shall be located within 12” of the curb side of the home.

6. The water supply inlet shall not be located under an exterior door.

7. Individual secondary shut off valves shall be located on each water line at each fixture, except at the tub/shower or shower.

8. All water line floor penetrations shall be caulked or foamed. Caulk or foam shall be acceptable to be in contact with the water line material.

9. Adequately sized access panels (12” x 12” min) shall be located in the walls at all points where concealed plumbing slip joints exist. The access panels shall match the wall color and finish. Access panels shall be unobstructed and accessible for inspection and repair.

10. The MHU shall be equipped with a frost-free hose bib located near the main water supply inlet. It shall not be located under an exterior door.

11. Low point drain in water lines with shut off valves shall be located above bottom board and insulation. Vendor to provide access panel, labeled, "Low Point Drain."

WATER LINES

Scale: 3/16" = 1'-0"

DRAWING NO.

Express MHU (Furnace)

8F-7

SANITARY TEE

LONG TURN TY

CLEAN OUT PLUG

CAP & CHAIN

22.5° ELL

45° ELL

REDUCER BUSHING

90° CLOSET ST. ELL

DWV FITTING LEGEND

MECHANICAL VENT

90° LONG TURN ELL

DOUBLE SANITARY TEE

90° LONG TURN ST. ELL

LK

P-TRAP

COUPLING

NM

T

R

S

Q

O P

45° Y

DOUBLE ELL

F

JI

H

B

D

E

G

A

C

To Sewer

H

K.Sink

K

A

B

Washer

M

F

Stool

D

A

M

F

Lav

K

A

Shower

M

(Stool Vent)

H

A

B

M

F

SEE NOTES 5 THRU 7

H

B

B

A

F

K

A

H

Notes

1. FITTING SIZES CORRESPOND TO ADJACENT PIPE SIZES.

2. SINGLE (THIN) LINES REPRESENT 1-1/2" PIPE;

DARK (THICK) LINES REPRESENT 2" PIPE;

DOUBLE LINES REPRESENT 3" PIPE.

3. P-TRAP DIRECTIONS MAY VARY.

Federal Emergency Management Agency

COMPANY:

Drain System General Notes

1. Drain lines shall be ABS or PVC and comply with the requirements of 24 CFR 3280.

2. All drain lines shall be 1 ½” diameter unless noted.

3. The drain line system shall be accessible without removing the axles and wheels.

4. All drain line floor penetrations, except at tub/shower and shower floor penetrations shall be caulked or foamed. Caulk or foam shall be acceptable to be in contact with the drain line material.

5. The drain line which shall run below the floor and above the bottom board to the place of drain outlet not less than two feet (2') but not more than three feet (3') in front of the axle group.

6. The drain line outlet shall protrude at least six inches (6”), but not more than eight inches (8”), below the bottom board.

7. The drain line outlet shall have a threaded end and will be capped with a removable plastic cap and chain or strap.

DRAIN LINES

Scale: 3/16" = 1'-0"

DRAWING NO.

Express MHU (Furnace)

8F-8

BATH

KITCHEN

LIVING/DINING AREA

BEDROOM

W/H

3060E

UTILITY

FIXED PANE

PANTRY

EXTERIOR

A/C

UNIT

x x

4'-8"40'-8"

20'-8"

16'-2

4"32'-8"

R

I S

E R

F

HVAC DESIGN AND

TITLE:

Scale: 3/16" = 1'-0"

Date: 6/28/2019FEMA Manufactured Housing Units

Federal Emergency Management Agency

DRAWING NO.

Express MHU (Furnace)

8F-9OVERHEAD DUCT DESIGN

HVAC General Notes

1. See FEMA specifications for programmable and configurable thermostat requirements.

2. Duct system shall be constructed of Class 0 or Class 1 circular insulated flex ductwork or equal. Circular flex duct shall be sized per duct design calculations. All ducts to be insulated with a minimum of

R-4 insulation.

3. Metal supply register sizes as shown on duct layout.

4. All supply ducts shall be in the roof attic space.

5. All supply duct seams and fasteners shall be sealed with UL-181A or UL-181B listed duct tape.

6. The manufacturer shall provide a duct pressure test report (See FEMA Spec for testing procedure) for each MHU duct system showing duct leakage of 5 percent or less prior to FEMA acceptance of the

MHU.

7. No construction debris or sawdust shall be left in the duct system.

8. Undercutting of interior doors is not permitted.

9. Return air grilles shall be sized per 24 CFR 3280.715(b)(4).

10. Return air grilles shall be located above interior doors or within interior walls (see partition prints for locations).

11. When the sprinkler system obstructs the return air grille, it may be located in the interior door or interior wall.

HVAC Split Furnace / AC Unit Notes

1. The furnace shall be at least a ninety-five percent (95%) efficient electric furnace (central heating system) capable of maintaining an average temperature of seventy degrees Fahrenheit (70°F) in the MHU.

2. The MHU shall be equipped with a specifically engineered HVAC split furnace /AC system based on the size and intended use of the MHU, in accordance with 24 CFR 3280.506, that is compatible with the HVAC split furnace /AC system size.

3. The furnace shall also be built or equipped for the installation of a split type air conditioner and have enclosed space in water heater/furnace compartment for an A-coil evaporator unit, and with a 4-wire thermostat completely wired and installed.

4. A vibration damping pad shall be placed between the condensing unit and the mounting platform.

5. A 1” ratchet strap with 500 lb. capacity shall be installed around the outside of the condenser unit and bracket extension for transportation.

6. Air conditioning lines shall be pre-charged in the factory per manufacturers specifications and shall not have any leaks.

7. Furnace return air return grill shall be sized per furnace manufacturer’s installation instructions.

8. Duct penetrations thru ceiling board shall be sealed.

Heating (10 KW Electric Furnace)

Furnace/ A/C Specifications

Cooling (1.5 Ton Air Conditioner)

BACK DOOR SIDE ELEVATION

HITCH END ELEVATION TAIL END ELEVATION

FRONT DOOR SIDE ELEVATION

BACK DOOR

ANGLE RAIN DIVERTER OVER DOOR

EXTERIOR

LIGHT

RIDGE VENT (TYP.)

TRANSPONDER

INTERIOR FLOOR LINE

VINYL SIDING BELOW DOORS TO COVER 2X8 PERIMETER RAILS.

PEEP

HOLES

OUTSIDE

CONDENSER

UNIT WITH

PROTECTIVE

COVER

ANGLE RAIN DIVERTER OVER DOOR

RIDGE VENT (TYP.)

PEEP

HOLES

FRONT DOOR

EXTERIOR

LIGHT

INTERIOR FLOOR LINE

8'-0" 8'-0"

3" 3"

M

A X

T

O

T

P

F

R

I D

G E

V

N

T

8'-6" EAVE TO EAVE MAX.

EXTERIOR

RECEPT. (GFCI)

3" 3"

M

T

R

I D

N

T

8'-6" EAVE TO EAVE MAX.

24"

DRYER VENT.

12"

HUD LABEL: APPROX. 12" UP FROM

FLOOR AND 12" FROM ROADSIDE.

RANGE EXHAUST FAN

EXTERIOR RECEPTACLE (GFCI)

SERVICE ENTRANCE BOX

HOSE BIB

OUTSIDE

CONDENSER

UNIT WITH

PROTECTIVE

COVER

FEMA Manufactured Housing Units

Federal Emergency Management Agency

TITLE: VERSION:

ELEVATIONS

Scale: 1/8" = 1'-0"

Date: 6/28/2019

DRAWING NO.

Express MHU (Furnace)

8F-10

Exterior Finish Notes

1. Siding shall be light gray vinyl.

2. Siding shall be double 4” lap.

3. Siding shall be approved for HUD Wind Zone III requirements.

4. The manufacturer shall provide a transponder sled. See Appendix A.

5. The sled shall be painted with a powder coat paint to match the exterior color of the MHU or white.

6. The transponder sled shall be made out of sheet metal.

32'-0" CTR. OF AXLES (66.7% OF FRAME LENGTH)

48"48"

16'-0" CTR. OF AXLES

32" 32"

10"x9# I-BEAM HEADER

10"x9# MAIN I-BEAM

CROSSMEMBER

(TYP)

Chassis Frame Notes

1. All metal-to-metal contact with 1/8” fillet weld minimum.

2. Floor shall be lagged to frame with frame clip, Fastec 9mm x 76mm listed lags or lags equivalent in size and strength at each joist and outrigger tip.

3. Clips shall be welded to the I-beam.

4. All parts of the chassis including added/welded parts shall be completely coated with waterproof paint.

5. Tires shall be new, 14.5” rim diameter, 14 ply with “G” load range.

6. Wheels and tires shall meet or exceed the axle rating and be rated for continuous speeds of 65 mph or greater.

7. All axles shall be new.

8. All axles shall be brake axles.

9. A valve stem cover shall be present on every tire.

10. The serial number shall be permanently stamped to the front header to comply with 3280.6. In addition, the serial number shall be painted with rust resistance contrasting color paint, 2 inches (2”) tall on the front header.

11. Rims, bolts, nuts, or other related tire-mounting hardware shall be new.

12. Longitudinal brackets shall be installed at 96” maximum from each end of the home.

13. Spring hangers shall be multi-leaf.

14. All rims shall be the same color.

15. Maximum typical pier spacing along main I-beams at 8' O.C. Typical pier load = 4250 lbs.

16. Manufacturer to place permanent indicators (paint or label) on each I-beam at 2'-0" in from each end, 12'-0" O.C. max.

and at door jambs for locations of temporary piers for storage.

17. Longitudinal bracket slot to face closest end of home

Frame Specs:

Main I-beam: 10X9#.

Front/Rear headers: 10x9#.

Cross members: 13 ga. C or Z, 1

"x3"x1

"@4'-0" O.C. Typ.

Outriggers: N/A.

Frame clip: 1"x1

"x12 ga.

Hitch Specs:

See Chassis Details, Detail "A"

Welding Specs:

1. All welds to be a minimum 1/8" unless otherwise noted. Weld beads can be concave in application as long as the weld size is met.

2. Coupler and jack shall be welded per manufacture's installation instructions.

3. I-beam splice plate shall be 4" wide x height of I-beam minus 1 1/4"x13 GA. splice plate can be offset +/- 1/4". Weld shall be full width of splice plate. Splice plate only required on one side of I-beam.

4. All weld lengths stated or shown are minimum lengths and shall have a tolerance of minus 1/4" (except spring hangers). Weld lengths that are not noted shall be full length.

SEE

APPENDIX A,

PG. A-40

32"

42"

21"

48'-0"

10"

(MOVED JOIST)

2'-2"

(ADDED JOIST)

5'-4"

6'-8"

9'-4"

10'-8"

13'-4"

14'-8"

17'-4"

18'-8"

21'-4"

22'-8"

26'-8"

28'-0"

29'-4"

30'-8"

32'-0"

33'-4"

34'-8"

36'-0"

37'-4"

38'-8"

42'-8"

41'-4" 45'-4"

46'-8"

FRAME CLIPS IN AXLE AREA ARE LOCATED ON INSIDE OF I-BEAM AS SHOWN.

2'-8"

25'-4"

10"x9# MAIN I-BEAM

13'-4" INSTALL TIRE BLOW-OUT

PROTECTION IN THIS AREA (BOTH SIDES)

25'-4" START BLOW-OUT PROTECTION

SEE CHASSIS DETAILS,

DETAIL "A"

DETAIL "B"

26'-9

2"

26"

6"

26"

6"

26"

6"

26"

28'-11

2"

29'-5

2"

31'-7

2"

32'-1

2"

34'-3

2"

34'-9

2"

36'-11

2"

96" LONGITUDINAL BRACKET

96" LONGITUDINAL BRACKET

SEE CHASSIS DETAILS, DETAIL "C"

4'-0"

9'-4"

12'-0"

16'-0" 20'-0"

24'-0"

40'-0" 44'-0"

13 GA. "C"

CROSSMEMBER

1-1/2"x3"x1-1/2"x2'

8"

8"

10 HOLES AT 10-1/4" O.C.

4"

- SPRING HANGER

DRAWING NOTES

FRAME CLIP DETAIL (SAME ON BOTH MAIN I-BEAMS).

**DIMS ARE PULLED FROM END OF HEADER BEAM.

**BE SURE TO VERIFY FLOOR JOIST LAYOUT TO MATCH CLIPS TO JOISTS.

FRONT AND REAR HEADER SHEARWALL LAG BOLT SPACING

" TYP. HOLE SPACING

LONGITUDINAL

BRACKET

LONGITUDINAL

BRACKET

32"48" 32" 48"48"48"48"48"32"

48'-0" 4'-0"8'-0"12'-0"16'-0"20'-0"24'-0"44'-0" 40'-0" 37'-4" 34'-8" 32'-0" 26'-8"29'-4"

10"x9# I-BEAM HEADER

CHASSIS

TITLE:

FEMA Manufactured Housing Units

Federal Emergency Management Agency

Scale: 3/16" = 1'-0"

Date: 6/28/2019

DRAWING NO.

Express MHU (Furnace)

8F-11.1

VERSION:

DRAWBAR I-BEAM - 12" X 10.8#

DRAWBAR CROSSMEMBER I-BEAM - 12" X 10.8#

REINFORCEMENT UNDER FRONT HEADER AND

CENTERED BETWEEN FRONT HEADER AND TONGUE.

VENTURE 2-5/16" - 60 DEGREE, 10,000 LB. COUPLER OR EQUIVALENT

JACK - VENTURE TOP MOUNT,

10,000 LB. GALVANIZED OR EQUIVALENT.

7-3/8" X 4" NOSE PLATE

1"x1 1/2"x12 GA. FRAME CLIP.

1/8" x 1-1/2" FILLET WELD TO TOP

FLANGE OF I-BEAM.

CROSSMEMBER -

C OR Z 1.5"x3"x1.5"

13 GA. AT 48" OC.

1-1/2" x 1-1/2" x 13 GA. ANGLE GUSSET

" x 1"L FILLET WELD TO I-BEAM AND

CROSSMEMBER

I-BEAM - 10" X 9# AT 68

"SPACING

FRONT AND REAR I-BEAM

HEADERS - 10" X 9#.

A

A

° BOTTOM OF

FRAME I-BEAM

1/8" x2" LONG

FILLET WELD

2"

SEE SLOT

DETAIL

" Ø HOLE

3"

4" 1

2"

4"

" Ø HOLES

SEE SLOT

DETAIL

" Ø HOLE

4" 1

2"

4"

2"1

2"

SLOT DETAIL

8"

16"

DETAIL "A-A"

" Ø

HOLE

SEE SLOT

DETAIL

F

U

L

L

M

A

X

M

A

X

N

O

W

E

L

D

1/4" FILLET WELD

EACH SIDE

Notes

1. Thickness is 4 gauge.

2. Vendor to assure all spring hangers are installed 90° to I-beam.

3. Shoulder bolts to be torqued per axle manufacturer requirements (Approximately

30 to 50 ft. lbs). Leaf spring to move freely in spring hanger.

I-BEAM FLANGE

LOOKING UP AT SPRING HANGER

SPRING HANGER

SPRING

HANGER

LEAF

SPRING

EQUALIZER

AXLE

U-BOLTS

LEAF

SPRING

SHACKLE LINK

WITH BOLTS

CENTER SPRING

HANGER

FRAME I-BEAM

FEMA Manufactured Housing Units

Federal Emergency Management Agency

COMPANY:

DETAIL C: LONGITUDINAL TIE-DOWN BRACKET

DETAIL B: SPRING HANGER WELDING

DETAIL A: HITCH ASSEMBLY

CHASSIS DETAILS

TITLE:

Scale: NTS

Date: 6/28/2019

DRAWING NO.

8F-11.2

VERSION:

Express MHU (Furnace)

LONGITUDINAL TIE-DOWN BRACKET (12 GA. MIN.) SHALL

HAVE 3150 LB. WORKING LOAD CAPACITY.

DETAIL D: EQUALIZER & SHACKLE LINK FASTENING

Notes

1. Shoulder bolts are to be used at all equalizer and shackle link locations.

2. Shoulder bolts shall be torqued per axle manufacturer requirements.

(Approximately 30 to 50 ft. lbs.)

3. Equalizer and shackle links are to move freely after shoulder bolts have been torqued.

4. Axle U-bolts shall be torqued per axle manufacturer requirements

(Approximately 70 to 95 ft. lbs.)

48'-0"

S

H E

A R

W A

L

J

I S

S

W

Z

S

H E

A R

W A

J

I S

W

Floor Framing Notes

1. The floor joists shall be 2 x 8 #2 SPF 16” o.c.

2. Edge rails shall be 2 x 8 #2 SPF.

3. Edge rail splice 4 x 5 x 20 GA metal connector plate on each side or 2 x 8 x min. 6" each side of joint block centered +/- 1”, to be fastened with 7/16 x 2 ½ x 15 GA staples or .131 x 3” PD nails (8) each side of edge rail with PVA 80% coverage.

Floor Insulation Notes

1. The insulation shall have a flame spread of 25 or less and a smoke development of 450 or less.

2. The floor insulation shall be a minimum of R-26 fiberglass blanket insulation. One full batt, one additional full width batt between the I-beams, and one additional 16” wide batt between joist outside of I-beams.

Bottom Board Notes

1. All penetrations sealed per bottom board manufacturer’s installation instructions.

2. Bottom board shall be a minimum of twenty (20) mil thickness.

3. Multiple layers of acceptable bottom board material per 3280.305(g)(6) may be used.

4. Fasten bottom board to perimeter framing per manufacturer’s installation instructions.

A D

D E

D

J O

I S

T

M O

V E

D

J O

I S

T

F

R O

M

J O

I S

T

O

C

U

N L

E S

S

N

O T

E D

28"

2 - 2x6x18" treated lumber backers for mounting service entrance junction box. Fasten thru bottom board into joists above with 2 - #8x3" stainless steel screws or hot dipped galvanized (G185) screws each end.

FLOOR FRAMING LAYOUT

FEMA Manufactured Housing Units

Federal Emergency Management Agency

COMPANY: VERSION:

Scale: 3/16" = 1'-0"

DRAWING NO.

Express MHU (Furnace)

8F-12

Floor joists to rim joist

Multiple joists (to each other)

(80% PVA glue coverage)

7/16 x 2-1/2 x 15Ga staple

OR 0.131 x 3" Nail

7/16 x 2-1/2 x 15Ga staple

OR 0.131 x 3" Nail

7 each

5 each

12" o.c.

12" o.c.

DESCRIPTION FASTENER QTY

FASTENING SCHEDULE - FLOOR FRAMING

Cut joist (header) to transv.

joist (straight or toenailed)

7/16 x 2-1/2 x 15Ga staple

OR 0.131 x 3" Nail

5 each

3 each

SHOWER

TOILET

4'-0"8'-0"8'-0"8'-0"8'-0"8'-0"4'-0"

8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0"

P-TRAP

W/H

FURNACE

23'-8" KIT SINK

16'-10

4"

38'-3

4"

11'-1

2" WASHER

11'-9" WASH DRAIN

10"

7'-6"

6'-1

4"

S H

O W

R

4'-4" LAV

2'-6"

5'-1" LAV

AUTOVENT

6" TOILET SUPPLY

1'-5"

Floor Decking Notes

1. The floor decking shall be 23/32” tongue-and-groove (T&G) OSB or APA-rated 24/0 index plywood laid out as shown in decking plan.

2. Decking shall be Exposure 1 rated.

3. Long edges of the panel shall be T&G installed perpendicular to the floor joist.

4. PVA (polyvinyl acetate) or equal shall be used as adhesive with 80% coverage.

5. Vinyl flooring shall be installed on all interior floors of the home installed per manufacturer’s installation instructions.

P.BOX

S

H O

W E

R

23'-0" KIT DRAIN

123456

7 6 5 4 3 2 1

A

B

PHONE

WIRE

TV WIRE

PHONE

WIRE

TV WIRE

33'-0"

44'-4"

45'-0"

DRAIN

6"

W/H

HOT &

COLD

32'-4"

DEHUMIDIFIER

22'-4"

9'-7

4"

39'-9

8"

S P

R I N

K L E

R

R I S

E R

Ø

Ø

S

P R

I N

K L E

R

D R

A I N

Federal Emergency Management Agency

COMPANY: VERSION:

FLOOR DECKING LAYOUT

Scale: 3/16" = 1'-0"

Date: 6/28/2019

DRAWING NO.

Express MHU (Furnace)

8F-13

Decking to Joists 7/16 x 1-3/4 x 16Ga staple

OR 0.092 x 2" Nail

4" edges / 6" field w/ glue

6" edges / 10" field w/ glue

DESCRIPTION FASTENER APPLICATION

FASTENING SCHEDULE - FLOOR DECKING

LIVING/DINING AREA

BEDROOM

P3

P1

P2

P4

P6

P5

P7

P8

W/H

UTILITY

P9

PANTRY

S2

E2

S1

E1

EXTERIOR

A/C

UNIT

2"

2"x8

2" x

4"

21"x8

4"

2" x

2"

2"

3"

General Notes

1. Gypsum to be jointed above all doors in line with jambs.

2. Horizontal and vertical gypsum layouts for interior walls are the same.

P13

F

P14

P15

P10

P11

P12

TOP PLATE SPLICE

BOTTOM PLATE SPLICE

2" X 4" X 20 GA.

Metal connector plate, one each side

Min 2" X 4" X 10" block centered over splice +/- 1" and fastened with

6-7/16" X 2 1/2" X 15 GA staples each side of splice

Min 2" X 4" X 10" block centered over splice +/- 1" and fastened with 6-7/16"

X 2 1/2" X 15 GA staples each side of splice

2" X 4" X 20 GA.

Metal connector plate, one each side

INTERIOR WALL/BACK PANEL PLAN

TITLE:

Scale: 3/16" = 1'-0"

Date: 6/28/2019FEMA Manufactured Housing Units

Federal Emergency Management Agency

DRAWING NO.

Express MHU (Furnace)

8F-14

Stud to top/bottom plate

Door header to stud or 0.131 x 3" nail

3 each

2 each

DESCRIPTION FASTENER APPLICATION

FASTENING SCHEDULE - INTERIOR WALLS

15 ga x 7/16"x 2-1/2" staple

Bottom plate to floor

12" o.c.

Gypsum to studs, 80% PVA glue

Alternative Gypsum to studs, 100% one part urathane glue

Gypsum to studs (shearwall)

Per product manufacturer's instructions

Stud to stud

Layflat to top/bottom plate

Top plate to ceiling or 0.131 x 3" nail

15 ga x 7/16"x 2-1/2" staple or 0.131 x 3" nail

15 ga x 7/16"x 2-1/2" staple

0.131 x 3" nail

15 ga x 7/16"x 2-1/2" staple

#8 x 3" screw

19 ga x 3/16"x 1-1/4" staple or drywall screw

Into layflat into trusses

19 ga x 3/16"x 1-1/4" staple or drywall screw

0.131 x 3" nail or #8 x 3" screw or

15 ga x 7/16"x 2-1/2" staple

2 each

3 each

2 each

12" o.c.

12" o.c.

12" o.c.

6" o.c. at edges and

12" o.c. in field

6" edges

12" o.c.

Interior wall to sidewall (non-shearwall)

Interior wall to interior wall

#8 screw (min. 1" penetration at 16" O.C.)

0.131 nail (min. 1" penetration at 16" O.C.)

#8 x 3" screw 6" o.c.

15 ga x 7/16"x 2-1/2" staple or 0.131 x 3" nail

Backers to stud

6 Each

15 ga X

" X 2

" staple or 0.131 X 3" nail

3 Each

(end grain only)

(end grain or toed)

RESERVED

Scale: NTS

Date: 6/28/2019FEMA Manufactured Housing Units

Federal Emergency Management Agency

DRAWING NO.

Express MHU (Furnace)

8F-15

P1

Gypsum Layout

COMPANY:

INTERIOR WALL

Date: 6/28/2019

DRAWING NO.

Express MHU (Furnace)

8F-16.1

Scale: 1/2" = 1'-0"

6. Wall panel trim (1/2” x 2”) shall be used to cover the gypsum panel joints. Trim fastened to only one of the two gypsum panels into stud. 10" O.C. fastener spacing.

7. Walls shall be sanded as needed to assure a smooth finish (level 3 finish minimum)

8. Paint shall be any latex paint. See FEMA spec.

9. Horizontal and vertical gypsum layouts are the same.

Interior Wall Framing Notes

1. All interior walls are 2 x 3 (unless noted) #2 SPF at 16” maximum o.c., except washer wall.

2. Top plates to be 2 x 3 (unless noted) #2 SPF.

3. Bottom plates to be 1 x 3 (unless noted) #2 SPF.

4. Wall interiors shall be faced with ½” Gold Bond XP gypsum board with paint or equivalent installed per ASTM C840 and GA-216.

5. Gypsum board shall run vertically or horizontally along the entire height of wall interiors. See fastening schedule.

25 1/2

P2

4 1/2 25 1/2 3

Gypsum Layout

4"

NOTCH FOR SPRINKLER SYSTEM PIPE

2x3x2

1x3x2

COMPANY:

INTERIOR WALL

Date: 6/28/2019

DRAWING NO.

Express MHU (Furnace)

8F-16.2

Scale: 1/2" = 1'-0"

6. Wall panel trim (1/2” x 2”) shall be used to cover the gypsum panel joints. Trim fastened to only one of the two gypsum panels into stud. 10" O.C. fastener spacing.

7. Walls shall be sanded as needed to assure a smooth finish (level 3 finish minimum)

8. Paint shall be any latex paint. See FEMA spec.

9. Horizontal and vertical gypsum layouts are the same.

Interior Wall Framing Notes

1. All interior walls are 2 x 3 (unless noted) #2 SPF at 16” maximum o.c., except washer wall.

2. Top plates to be 2 x 3 (unless noted) #2 SPF.

3. Bottom plates to be 1 x 3 (unless noted) #2 SPF.

4. Wall interiors shall be faced with ½” Gold Bond XP gypsum board with paint or equivalent installed per ASTM C840 and GA-216.

5. Gypsum board shall run vertically or horizontally along the entire height of wall interiors. See fastening schedule.

P3 x x

B

A C

K E

R

D

N

BCKR

DOWN

2X6

T

O W

E L

B

A R

Gypsum Layout

2x4 studs

2x4 top plate

1x4 bottom plate

V T

R

L O

C A

T I O

N

BCKR

DOWN

2X6

COMPANY:

INTERIOR WALL

Scale: 1/2" = 1'-0"

Date: 6/28/2019

DRAWING NO.

Express MHU (Furnace)

8F-16.3

6. Wall panel trim (1/2” x 2”) shall be used to cover the gypsum panel joints. Trim fastened to only one of the two gypsum panels into stud. 10" O.C. fastener spacing.

7. Walls shall be sanded as needed to assure a smooth finish (level 3 finish minimum)

8. Paint shall be any latex paint. See FEMA spec.

9. Horizontal and vertical gypsum layouts are the same.

Interior Wall Framing Notes

1. All interior walls are 2 x 3 (unless noted) #2 SPF at 16” maximum o.c., except washer wall.

2. Top plates to be 2 x 3 (unless noted) #2 SPF.

3. Bottom plates to be 1 x 3 (unless noted) #2 SPF.

4. Wall interiors shall be faced with ½” Gold Bond XP gypsum board with paint or equivalent installed per ASTM C840 and GA-216.

5. Gypsum board shall run vertically or horizontally along the entire height of wall interiors. See fastening schedule.

37 1/2

P4 x x

B

A C

K E

R

U

P

Gypsum Layout

47 1/2 37 1/2x8 3/4 3

NOTCH FOR SPRINKLER

SYSTEM PIPE

NOTCH FOR SPRINKLER

SYSTEM PIPE

2x3x2

1x3x2

4"

14"x14" access panel (Oatley 34056 or equivalent). Panel cut gypsum access panels are not acceptable.

19 3/4 14

4 1/4

COMPANY:

INTERIOR WALL

Date: 6/28/2019

DRAWING NO.

Express MHU (Furnace)

8F-16.4

Scale: 1/2" = 1'-0"

6. Wall panel trim (1/2” x 2”) shall be used to cover the gypsum panel joints. Trim fastened to only one of the two gypsum panels into stud. 10" O.C. fastener spacing.

7. Walls shall be sanded as needed to assure a smooth finish (level 3 finish minimum)

8. Paint shall be any latex paint. See FEMA spec.

9. Horizontal and vertical gypsum layouts are the same.

Interior Wall Framing Notes

1. All interior walls are 2 x 3 (unless noted) #2 SPF at 16” maximum o.c., except washer wall.

2. Top plates to be 2 x 3 (unless noted) #2 SPF.

3. Bottom plates to be 1 x 3 (unless noted) #2 SPF.

4. Wall interiors shall be faced with ½” Gold Bond XP gypsum board with paint or equivalent installed per ASTM C840 and GA-216.

5. Gypsum board shall run vertically or horizontally along the entire height of wall interiors. See fastening schedule.

P5

BCKR

UP

2X6

BCKR

UP

2X6

Gypsum Layout

28 1/2

COMPANY:

INTERIOR WALL

Date: 6/28/2019

DRAWING NO.

Express MHU (Furnace)

8F-16.5

Scale: 1/2" = 1'-0"

6. Wall panel trim (1/2” x 2”) shall be used to cover the gypsum panel joints. Trim fastened to only one of the two gypsum panels into stud. 10" O.C. fastener spacing.

7. Walls shall be sanded as needed to assure a smooth finish (level 3 finish minimum)

8. Paint shall be any latex paint. See FEMA spec.

9. Horizontal and vertical gypsum layouts are the same.

Interior Wall Framing Notes

1. All interior walls are 2 x 3 (unless noted) #2 SPF at 16” maximum o.c., except washer wall.

2. Top plates to be 2 x 3 (unless noted) #2 SPF.

3. Bottom plates to be 1 x 3 (unless noted) #2 SPF.

4. Wall interiors shall be faced with ½” Gold Bond XP gypsum board with paint or equivalent installed per ASTM C840 and GA-216.

5. Gypsum board shall run vertically or horizontally along the entire height of wall interiors. See fastening schedule.

37 1/2

P6

B

A C

K E

R

U

P

Gypsum Layout

43 1/2 37 1/2x8 3/4 7

RAG

2-1/4"

1x FILLER

2x BLOCK 18" MIN.

M

I N

NOTCH FOR SPRINKLER SYSTEM PIPE

-SEE APPENDIX A-30 DETAIL "B"

NOTCH FOR SPRINKLER

SYSTEM PIPE

54 7/8 14 3/4

RAG

2x6 SPRINKLER HEAD BACKER UP. SPRINKLER HEAD BACKER

LOCATION MAY VARY BASED ON SPRINKLER DESIGN.

COMPANY:

INTERIOR WALL

Date: 6/28/2019

DRAWING NO.

Express MHU (Furnace)

8F-16.6

Scale: 1/2" = 1'-0"

6. Wall panel trim (1/2” x 2”) shall be used to cover the gypsum panel joints. Trim fastened to only one of the two gypsum panels into stud. 10" O.C. fastener spacing.

7. Walls shall be sanded as needed to assure a smooth finish (level 3 finish minimum)

8. Paint shall be any latex paint. See FEMA spec.

9. Horizontal and vertical gypsum layouts are the same.

Interior Wall Framing Notes

1. All interior walls are 2 x 3 (unless noted) #2 SPF at 16” maximum o.c., except washer wall.

2. Top plates to be 2 x 3 (unless noted) #2 SPF.

3. Bottom plates to be 1 x 3 (unless noted) #2 SPF.

4. Wall interiors shall be faced with ½” Gold Bond XP gypsum board with paint or equivalent installed per ASTM C840 and GA-216.

5. Gypsum board shall run vertically or horizontally along the entire height of wall interiors. See fastening schedule.

25 1/2

P7

Gypsum Layout

1 1/2 25 1/2

1 1/2

COMPANY:

INTERIOR WALL

Date: 6/28/2019

DRAWING NO.

Express MHU (Furnace)

8F-16.7

Scale: 1/2" = 1'-0"

6. Wall panel trim (1/2” x 2”) shall be used to cover the gypsum panel joints. Trim fastened to only one of the two gypsum panels into stud. 10" O.C. fastener spacing.

7. Walls shall be sanded as needed to assure a smooth finish (level 3 finish minimum)

8. Paint shall be any latex paint. See FEMA spec.

9. Horizontal and vertical gypsum layouts are the same.

Interior Wall Framing Notes

1. All interior walls are 2 x 3 (unless noted) #2 SPF at 16” maximum o.c., except washer wall.

2. Top plates to be 2 x 3 (unless noted) #2 SPF.

3. Bottom plates to be 1 x 3 (unless noted) #2 SPF.

4. Wall interiors shall be faced with ½” Gold Bond XP gypsum board with paint or equivalent installed per ASTM C840 and GA-216.

5. Gypsum board shall run vertically or horizontally along the entire height of wall interiors. See fastening schedule.

P8

Gypsum Layout

19 1/2

2x6 studs

2x6 top plate

1x6 bottom plate

NOTCH FOR

SPRINKLER

SYSTEM PIPE

2-1/4"

1x

FILLER

SEE APPENDIX A-30 DETAIL "B"

19 1/2

41 1/2

COMPANY:

INTERIOR WALL

Date: 6/28/2019

DRAWING NO.

Express MHU (Furnace)

8F-16.8

Scale: 1/2" = 1'-0"

6. Wall panel trim (1/2” x 2”) shall be used to cover the gypsum panel joints. Trim fastened to only one of the two gypsum panels into stud. 10" O.C. fastener spacing.

7. Walls shall be sanded as needed to assure a smooth finish (level 3 finish minimum)

8. Paint shall be any latex paint. See FEMA spec.

9. Horizontal and vertical gypsum layouts are the same.

Interior Wall Framing Notes

1. All interior walls are 2 x 3 (unless noted) #2 SPF at 16” maximum o.c., except washer wall.

2. Top plates to be 2 x 3 (unless noted) #2 SPF.

3. Bottom plates to be 1 x 3 (unless noted) #2 SPF.

4. Wall interiors shall be faced with ½” Gold Bond XP gypsum board with paint or equivalent installed per ASTM C840 and GA-216.

5. Gypsum board shall run vertically or horizontally along the entire height of wall interiors. See fastening schedule.

P9

P A

N E

L

B

O X

Gypsum Layout

26 1/2

2x4 studs

2x4 top plate

1x4 bottom plate

E L

E C

T R

I C

A L

P A

N E

L

B

O X

E L

E C

T R

I C

COMPANY:

INTERIOR WALL

Date: 6/28/2019

DRAWING NO.

Express MHU (Furnace)

8F-16.9

Scale: 1/2" = 1'-0"

6. Wall panel trim (1/2” x 2”) shall be used to cover the gypsum panel joints. Trim fastened to only one of the two gypsum panels into stud. 10" O.C. fastener spacing.

7. Walls shall be sanded as needed to assure a smooth finish (level 3 finish minimum)

8. Paint shall be any latex paint. See FEMA spec.

9. Horizontal and vertical gypsum layouts are the same.

Interior Wall Framing Notes

1. All interior walls are 2 x 3 (unless noted) #2 SPF at 16” maximum o.c., except washer wall.

2. Top plates to be 2 x 3 (unless noted) #2 SPF.

3. Bottom plates to be 1 x 3 (unless noted) #2 SPF.

4. Wall interiors shall be faced with ½” Gold Bond XP gypsum board with paint or equivalent installed per ASTM C840 and GA-216.

5. Gypsum board shall run vertically or horizontally along the entire height of wall interiors. See fastening schedule.

P10

Gypsum Layout

25 1/2

COMPANY:

INTERIOR WALL

Date: 6/28/2019

DRAWING NO.

Express MHU (Furnace)

8F-16.10

Scale: 1/2" = 1'-0"

6. Wall panel trim (1/2” x 2”) shall be used to cover the gypsum panel joints. Trim fastened to only one of the two gypsum panels into stud. 10" O.C. fastener spacing.

7. Walls shall be sanded as needed to assure a smooth finish (level 3 finish minimum)

8. Paint shall be any latex paint. See FEMA spec.

9. Horizontal and vertical gypsum layouts are the same.

Interior Wall Framing Notes

1. All interior walls are 2 x 3 (unless noted) #2 SPF at 16” maximum o.c., except washer wall.

2. Top plates to be 2 x 3 (unless noted) #2 SPF.

3. Bottom plates to be 1 x 3 (unless noted) #2 SPF.

4. Wall interiors shall be faced with ½” Gold Bond XP gypsum board with paint or equivalent installed per ASTM C840 and GA-216.

5. Gypsum board shall run vertically or horizontally along the entire height of wall interiors. See fastening schedule.

P11

Gypsum Layout

5 1/4 21x8 1/2

5 1/4

COMPANY:

INTERIOR WALL

Date: 6/28/2019

DRAWING NO.

Express MHU (Furnace)

8F-16.11

Scale: 1/2" = 1'-0"

6. Wall panel trim (1/2” x 2”) shall be used to cover the gypsum panel joints. Trim fastened to only one of the two gypsum panels into stud. 10" O.C. fastener spacing.

7. Walls shall be sanded as needed to assure a smooth finish (level 3 finish minimum)

8. Paint shall be any latex paint. See FEMA spec.

9. Horizontal and vertical gypsum layouts are the same.

Interior Wall Framing Notes

1. All interior walls are 2 x 3 (unless noted) #2 SPF at 16” maximum o.c., except washer wall.

2. Top plates to be 2 x 3 (unless noted) #2 SPF.

3. Bottom plates to be 1 x 3 (unless noted) #2 SPF.

4. Wall interiors shall be faced with ½” Gold Bond XP gypsum board with paint or equivalent installed per ASTM C840 and GA-216.

5. Gypsum board shall run vertically or horizontally along the entire height of wall interiors. See fastening schedule.

P12

Gypsum Layout

25 1/2

COMPANY:

INTERIOR WALL

Date: 6/28/2019

DRAWING NO.

Express MHU (Furnace)

8F-16.12

Scale: 1/2" = 1'-0"

6. Wall panel trim (1/2” x 2”) shall be used to cover the gypsum panel joints. Trim fastened to only one of the two gypsum panels into stud. 10" O.C. fastener spacing.

7. Walls shall be sanded as needed to assure a smooth finish (level 3 finish minimum)

8. Paint shall be any latex paint. See FEMA spec.

9. Horizontal and vertical gypsum layouts are the same.

Interior Wall Framing Notes

1. All interior walls are 2 x 3 (unless noted) #2 SPF at 16” maximum o.c., except washer wall.

2. Top plates to be 2 x 3 (unless noted) #2 SPF.

3. Bottom plates to be 1 x 3 (unless noted) #2 SPF.

4. Wall interiors shall be faced with ½” Gold Bond XP gypsum board with paint or equivalent installed per ASTM C840 and GA-216.

5. Gypsum board shall run vertically or horizontally along the entire height of wall interiors. See fastening schedule.

P13

Horizontal Back Panel Gypsum Layout

60 1/2

2x3 studs

2x3 top plate

1x3 bottom plate

Dryer vent hole to exterior

WASHER/DRYER

12 1/2

Optional Back Panel Vertical Gypsum Layout

Nail on washer box size will vary. Manufacturer to verify size from the washer box vendor that will be used.

m a x

Gypsum is shown from the back side.

*Jig Side is NOT to have Gypsum

6 3/8

13 1/4

15 1/214

This wall not to be paneled on framing jig.

6"x9" louvered access panel (Oatley 34247 or equivalent) for recessed autovent

14"x14" washer p-trap access panel

(Oatley 34056 or equivalent)

To be paneled after floor plumbing is installed.

Standpipe cannot be more than 30" above the p-trap weir.

COMPANY:

INTERIOR WALL

Date: 6/28/2019

DRAWING NO.

Express MHU (Furnace)

8F-16.13

Scale: 1/2" = 1'-0"

6. Wall panel trim (1/2” x 2”) shall be used to cover the gypsum panel joints. Trim fastened to only one of the two gypsum panels into stud. 10" O.C. fastener spacing.

7. Walls shall be sanded as needed to assure a smooth finish (level 3 finish minimum)

8. Paint shall be any latex paint. See FEMA spec.

Interior Wall Framing Notes

1. All interior walls are 2 x 3 (unless noted) #2 SPF at 16” maximum o.c., except washer wall.

2. Top plates to be 2 x 3 (unless noted) #2 SPF.

3. Bottom plates to be 1 x 3 (unless noted) #2 SPF.

4. Wall interiors shall be faced with ½” Gold Bond XP gypsum board with paint or equivalent installed per ASTM C840 and GA-216.

5. Gypsum board shall run vertically or horizontally along the entire height of wall interiors. See fastening schedule.

P14

Gypsum Layout

2x3 studs laid flat

2x3 top plate laid flat

2x3 bottom plate laid flat

2 1/2

COMPANY:

INTERIOR WALL

Date: 6/28/2019

DRAWING NO.

Express MHU (Furnace)

8F-16.14

Scale: 1/2" = 1'-0"

6. Wall panel trim (1/2” x 2”) shall be used to cover the gypsum panel joints. Trim fastened to only one of the two gypsum panels into stud. 10" O.C. fastener spacing.

7. Walls shall be sanded as needed to assure a smooth finish (level 3 finish minimum)

8. Paint shall be any latex paint. See FEMA spec.

9. Horizontal and vertical gypsum layouts are the same.

Interior Wall Framing Notes

1. All interior walls are 2 x 3 (unless noted) #2 SPF at 16” maximum o.c., except washer wall.

2. Top plates to be 2 x 3 (unless noted) #2 SPF.

3. Bottom plates to be 1 x 3 (unless noted) #2 SPF.

4. Wall interiors shall be faced with ½” Gold Bond XP gypsum board with paint or equivalent installed per ASTM C840 and GA-216.

5. Gypsum board shall run vertically or horizontally along the entire height of wall interiors. See fastening schedule.

V

A T

O R

Y

T

O

C

L

M

E D

I C

I N

E

C

A B

I N

C

K E

R

P15

BCKR

DOWN

2X6

2x4 studs

2x4 top plate

1x4 bottom plate

BCKR

DOWN

2X6

BCKR

DOWN

2X6

DOUBLE

BCKR

DOWN

2X6

6"x9" LOUVERED

ABS ACCESS

PANEL (OATEY

34247 OR

EQUIVALENT)

FOR RECESSED

AUTOVENT.

Back Panel Gypsum Layout

Gypsum is shown from the back side.

*Jig Side is NOT to have Gypsum

6 3/8

20 1/2

7 1/8

COMPANY:

INTERIOR WALL

Scale: 1/2" = 1'-0"

Date: 6/28/2019

DRAWING NO.

Express MHU (Furnace)

8F-16.15

6. Wall panel trim (1/2” x 2”) shall be used to cover the gypsum panel joints. Trim fastened to only one of the two gypsum panels into stud. 10" O.C. fastener spacing.

7. Walls shall be sanded as needed to assure a smooth finish (level 3 finish minimum)

8. Paint shall be any latex paint. See FEMA spec.

9. Horizontal and vertical gypsum layouts are the same.

Interior Wall Framing Notes

1. All interior walls are 2 x 3 (unless noted) #2 SPF at 16” maximum o.c., except washer wall.

2. Top plates to be 2 x 3 (unless noted) #2 SPF.

3. Bottom plates to be 1 x 3 (unless noted) #2 SPF.

4. Wall interiors shall be faced with ½” Gold Bond XP gypsum board with paint or equivalent installed per ASTM C840 and GA-216.

5. Gypsum board shall run vertically or horizontally along the entire height of wall interiors. See fastening schedule.

E1

BATHROOM

A C

K E

R

U

P

OPTIONAL VERTICAL WALL BOARD PANEL BREAKS

H

O R

I Z

O N

T A

L

P A

N E

L

S

I Z

E

P

L I C

A B

L E

O R

I Z

O N

T A

L

P A

N E

L

S

I Z

E

P

L I C

A B

L E x x

B A

C K

U

2x6 sprinkler head backer up.

Sprinkler head backer location may vary based on sprinkler design.

TOP PLATE SPLICE

NTS

BOTTOM PLATE SPLICE

NTS

3" X 5" X 20 GA.

Metal connector plate, one each side

Min 2" X 4" X 10" block centered over splice +/- 1" and fastened with full coverage approved adhesive and

6-7/16" X 2 1/2" X 15 GA staples or

4-.131x3" nails each side of splice

Min 2" X 4" X 10" block centered over splice +/- 1" and fastened with full coverage approved adhesive and

6-7/16" X 2 1/2" X 15 GA staples or

4-.131x3" nails each side of splice

3" X 5" X 20 GA.

Metal connector plate, one each side

Federal Emergency Management Agency

COMPANY:

Wall Framing Notes

1. The exterior wall framing shall be 2 x 4 nominal #2 SPF at 16” o.c.

2. Wall framing shall be 7'-6” from floor to ceiling.

3. Sidewall top plates shall be single 2 x 4 nominal #2 SPF.

4. Sidewall bottom plate shall be single 1 x 4 nominal #2 SPF.

5. All major joints - wall to wall, wall to ceiling, wall to floor shall be caulked or gasketed to prevent air infiltration.

6. The wall insulation shall be R-13 and will be installed without voids, gaps, or compression.

7. 7/16” APA-rated 24/16 index oriented strand board (OSB) shall be attached to the wall studs.

8. The walls shall be painted with latex, low-VOC paint (10 mil wet film thickness) that shall qualify as a vapor retarder.

9. Housewrap applied over exterior sheathing.

10. All exterior penetrations (doors, vents, lights, outlets, etc.) shall be…