MANUFACTURED HOUSING UNIT

FEDERAL EMERGENCY MANAGEMENT AGENCY

NEXT GEN 2 BEDROOM UNIT

(FURNACE / AC SYSTEM)

JUNE 28, 2019

VERSION 1

TITLE:

1/8" = 1'-0"

6/28/2019FEMA Manufactured Housing Units

Federal Emergency Management Agency

DRAWING NO.

14' WIDE MHU (FURNACE)

DATE:

SCALE:

COMPANY: VERSION:

14F2-1.1

COVER PAGE

. Jun 28, 2019

DWG. NO.

TITLE

14F2-1.1

14F2-1.2

14F2-1.3

GENERAL NOTES

14F2-2

FLOOR PLAN

14F2-3

14F2-4.1

14F2-5

DOOR AND WINDOW SCHEDULE

14F2-6

14F2-7

DRAIN LINES

14F2-8

HVAC DESIGN AND OVERHEAD DUCT LAYOUT

14F2-9

INTERIOR WALL AND BACKPANELING LAYOUT (HORIZONTAL)

14F2-10

INTERIOR WALLS

14F2-11.1

SHEARWALL FRAMING AND EXTERIOR SHEATHING

14F2-12

ROOF FRAMING LAYOUT

14F2-13

ROOF SHEATHING LAYOUT

14F2-14

14F2-15

14F2-16.1-16.13

14F2-17.1-17.2

14F2-18.1

14F2-19

14F2-20

ROOF OVERHANG DETAIL

14F2-21

14F2-22

SPRINKLER SYSTEM LAYOUT

14F2-23

TRANSIT PROTECTION DETAILS

RESERVED

14F2-25.1

14F2-26

14F2-27

14F2-28

COVER PAGE

INDEX

UFAS LAYOUT

ELECTRICAL PLAN

WATER LINES

FURNITURE PLAN

FLOOR DECKING LAYOUT

INTERIOR WALL AND BACKPANELING LAYOUT (VERTICAL) - OPTIONAL

ELEVATIONS

CHASSIS

FLOOR FRAMING LAYOUT

ENDWALL FRAMING AND INTERIOR SHEATHING

SHIP LOOSE LAYOUT

FRONT DOOR SIDEWALL

BACK DOOR SIDEWALL

TIE DOWN SYSTEM

14F2-29.1

EXTERIOR WALL TIEDOWN DETAILS

14F2-29.2

KITCHEN ELEVATIONS

14F2-24.1

BATHROOM #1 ELEVATIONS

14F2-24.2

RESERVED

14F2-24.3

DOUBLE STACK PIER LAYOUT AND DETAILS

14F2-30

INDEX

14F2-11.2

CHASSIS DETAILS

RESERVED

14F2-18.2

RESERVED

14F2-25.2

14F2-4.2

INSTALLED FURNITURE LAYOUT

DWG. NO.

TITLE

A-1

A-2

A-3

COVER PAGE

MISCELLANEOUS HEIGHT REQUIREMENT DETAILS

APPENDIX A

MISCELLANEOUS HEIGHT REQUIREMENT DETAILS

A-4

KITCHEN SINK ACCESS PANEL DETAILS

A-10

DOOR DETAILS

A-11

DOOR FLASHING DETAILS

A-20

WINDOW DETAILS

A-21

WINDOW FLASHING DETAILS

A-30

MISCELLANEOUS DETAILS

A-40

CHASSIS AC MOUNT DETAILS

A-50

TPS CLOSET PLAN AND NOTES (14' WIDE)

A-51

TPS CLOSET ELEVATIONS (14' WIDE)

A-52

TPS CLOSET DETAILS (14' WIDE)

A-31

A-32

MISCELLANEOUS DETAILS

MISCELLANEOUS DETAILS

A-60

SPRINKLER RISER PLAN AND DETAIL (8' WIDE EXPRESS)

6/28/2019FEMA Manufactured Housing Units

Federal Emergency Management Agency

DRAWING NO.

14' WIDE MHU (FURNACE)

DATE:

SCALE:

COMPANY: VERSION:

14F2-1.2

INDEX

MANUFACTURED HOUSING UNIT

FEDERAL EMERGENCY MANAGMENT AGENCY

GENERAL NOTES

CODES AND STANDARDS

Manufactured Home Construction and Safety Standards 24 CFR 3280

Manufactured Home Procedural and Enforcement Regulations 24 CFR 3282

Uniform Federal Accessibility Standards (UFAS)

Standard for the Installation of Sprinkler Systems in Manufactured Homes (NFPA 13D)

Referenced 2005 National Electrical Code (NFPA 70) Articles as Incorporated in HUD 24 CFR 3280

STRUCTURAL LOADS

Floor Live Load 40 PSF

Floor Dead Load 10 PSF

Roof Live Load 40 PSF

Roof Dead Load 10 PSF

Comply with Wind Zone 3 Requirements of 24 CFR 3280

Wood Roof Diaphragm

Wall Height: 7'-6"

6/28/2019FEMA Manufactured Housing Units

Federal Emergency Management Agency

14' WIDE MHU (FURNACE)

DATE:

SCALE:

COMPANY: VERSION:

14F2-1.3

DRAWING NO.

GENERAL NOTES

R E

F E

R

3060-E-SG

SEAT

W/H

30603060

B A

T H

BEDROOM #1

TPS

CLOSET

D R

Y E

R W

A S

H E

R

3060-E-SG

PANTRY

KITCHEN

BEDROOM #2

P.BOX

5'-7"

2"

21'-0

2"

2"

4'-9"

2"

8'-0"

2"

7'-3

2"

8'-2"

2" 2

2"

5'-2

2"

2"

1'-10

2"

42'-3

2" 7'-9

2"

43'-9

4"

37'-0

2" 31'-4

4" 26'-8

4" 16'-10

4"

36'-4

4" 18'-8

4" 4'-0

4"

2'-4

2"

2"

R A

G x

A

G

84.00 SF

85.00 SF

50'-8"

LIVING & DINING

ROOM

16'-0"21'-0

2"42'-3

2"48'-1"

DESIGNATES A 2X4 WALL

SHEARWALLS - WIND ZONE 3

PLFLENGTHNO.

162"1

SIDEWALL HEIGHT = 90"

162" 405

TRUSS HEEL HEIGHT = 9-15/16"

LIGHT AND VENT SCHEDULE

REQUIRED VENTREQUIRED LIGHTROOM TITLE AREA

6.40 S.F.12.80 S.F.LIVING / DINING ROOM 160.00 S.F

3.36 S.F.6.72 S.F.BEDROOM #1 84.00 S.F.

3.40 S.F.6.80 S.F.BEDROOM #2 85.00 S.F.

160.00 SF

6"

6"

18'-6"

SHEAR WALLS FOR WIND ZONE 3

EXTERIOR

A/C UNIT

F

R.A.G.

6/28/2019FEMA Manufactured Housing Units

Federal Emergency Management Agency

14' WIDE MHU (FURNACE)

DATE:

SCALE:

COMPANY: VERSION:

14F2-2

DRAWING NO.

FLOOR PLAN

F E

R

3060-E-SG

SEAT

W/H

30603060

B A

BEDROOM #1

TPS

CLOSET

D R

Y E

R W

A S

H E

R

3060-E-SG

PANTRY

KITCHEN

BEDROOM #2

P.BOX

LIVING & DINING

ROOM

D1

D3

D1

D1

D2

D2

D2 D3

D3

MARK

D1

D2

D3

WIDTH

3'-0"

3'-0"

2'-0"

HEIGHT

6'-8"

6'-8"

6'-8"

THICKNESS

1-3/8"

1-3/8"

1-3/8"

TYPE

Outswing Door

Hallway Doors

Closet & W/H Doors *

DOOR SCHEDULE

MARK

W1

W2

WIDTH

2'-6"

2'-6"

HEIGHT

5'-0"

2'-3"

TYPE

Single Hung Window

Fixed Pane Window

WINDOW SCHEDULE

W2 W1

W1 W1W1

TOTAL EXTERIOR DOOR AREA: 62.67 SQ. FT.

TOTAL WINDOW AREA: 51.3 SQ. FT.

EXTERIOR

A/C UNIT

F

Door Notes

1. Exterior doors shall meet 24 CFR 3280.405 requirements and shall comply with Wind Zone 3 requirements.

2. All exterior doors shall be insulated fiberglass or steel with a maximum

U-Value of 0.33.

3. All doors shall have lever type handles in compliance with UFAS

4.13.9.

4. For additional information on exterior and interior doors see FEMA specifications and Appendix A.

5. Return air grills shall be installed above doors unless the grill will be blocked by the sprinkler system and then may be installed in the door or wall.

6. Door stops shall be installed at all interior and wardrobe doors. Door stops may be installed on the door or the floor baseboard. Door stop finish to match interior hardware finish.

7. All bathroom and bedroom doors shall have a privacy lock. The lock mechanism shall be the button type (UFAS 4.13.9) and located on the inside of the bathroom or bedroom.

8. The water heater compartment side of the water heater access door shall be covered with minimum 5/16 inch thick gypsum board.

9. The closet doors shall be equipped with a passage lock.

Window Notes

1. Windows shall meet 24 CFR 3280.403 and 3280.404 requirements and shall comply with Wind Zone 3 requirements.

2. Windows shall be double paned, low E with vinyl frame. Windows shall have a maximum SHGC of 0.30 and a maximum U-Value of 0.36.

3. Windows shall have a design pressure rating of 58.

4. Windows shall have screens.

6/28/2019FEMA Manufactured Housing Units

Federal Emergency Management Agency

14' WIDE MHU (FURNACE)

DATE:

SCALE:

COMPANY: VERSION:

14F2-3

DRAWING NO.

DOOR AND WINDOW SCHEDULE

R E

F E

R

SEAT

W/H

B A

BEDROOM #1

TPS

CLOSET

D R

Y E

R W

A S

H E

R

NIGHT-

STAND

C O

F F

A B

L E

TABLE

END-

PANTRY

NIGHT-

STAND

KITCHEN

BEDROOM #2

P.BOX

LIVING & DINING

ROOM

50'-8"

D R

E S

S E

R

D R

E S

S E

R

EXTERIOR

A/C UNIT

F

ITEM

SOFA

ARM-CHAIR

COFFEE TABLE

SPECIFICATIONS

72" W x 36" D

36" W x 32" D

30" W x 18" D

LIVING ROOM

END TABLE 12" W x 12" D

ITEM

DINING TABLE

DINING CHAIR

PANTRY

SPECIFICATIONS

72" L x 36" W

6 Identical Chairs

36" W x 12" D

DINING ROOM

ITEM

FULL BED

BUNK BED

DRESSER (4 DRAWER)

SPECIFICATIONS

75" L x 54" W

75" L x 39" W

48" W x 18" D

BEDROOMS

NIGHTSTAND 12" W x 12" D

ITEM

MEDICINE CABINET

BATH TUB

WC

SPECIFICATIONS

15" W x 25" H X 3" D

30" W x 60" L, FIBERGLASS

SEE FEMA SPEC

BATHROOM

WATER HEATER 40 GALLONS

ITEM

REFRIGERATOR

RANGE

MICROWAVE

SPECIFICATIONS

30" W x 32.5" D, 18 CU. FT.

30" W, 4 BURNERS

19" D MIN., 1.2 CU. FT.

KITCHEN

DEHUMIDIFIER PER FEMA

FEMA SUPPLIED

DEHUMIDIFIER

TITLE:

1/8" = 1'-0"

6/28/2019FEMA Manufactured Housing Units

Federal Emergency Management Agency

14' WIDE MHU (FURNACE)

DATE:

SCALE:

COMPANY: VERSION:

14F2-4.1

DRAWING NO.

FURNITURE PLAN

Furniture and Appliance Notes

1. All refrigerators shall be ENERGY STAR qualified and have the ENERGY STAR label affixed to the appliance when delivered with the MHU.

2. Range and oven controls shall be at the front of the appliance.

3. The range hood shall extend the width of the range and a minimum of 3" beyond the front face of the overhead cabinet.

4. The range hood vent opening at the cap shall be screened with a corrosion-resistant, non-combustible wire mesh with

1/4" openings or equivalent.

5. A shower rod and new, neutral-colored plastic shower curtain (71" L x 71" H) with full set of rings/hooks shall be provided for all shower/bath fixtures.

6. Two (2) metal, rust-resistant, wall-mounted towel bars with chrome finish shall be installed in each bathroom.

7. Metal, rust-resistant, toilet-paper holder with chrome finish shall be installed in each bathroom.

8. Mattresses shall be innerspring, non-latex (can be polyester, cotton, or blend ticking and wadding) new mattresses with medium firmness and 9" to 11" height.

9. The range hood vent shall be vented through the exterior wall.

R E

F E

R

SEAT

W/H

B A

BEDROOM #1

TPS

CLOSET

D R

Y E

R W

A S

H E

R

NIGHT-

STAND

C O

F F

B

L E

TABLE

END-

PANTRY

NIGHT-

STAND

KITCHEN

BEDROOM #2

P.BOX

LIVING & DINING

ROOM

50'-8"

D R

E S

S E

R

D R

E S

S E

R

EXTERIOR

A/C UNIT

F

FEMA SUPPLIED

DEHUMIDIFIER

TITLE:

1/8" = 1'-0"

6/28/2019FEMA Manufactured Housing Units

Federal Emergency Management Agency

14' WIDE MHU (FURNACE)

DATE:

SCALE:

COMPANY: VERSION:

14F2-4.2

DRAWING NO.

INSTALLED FURNITURE LAYOUT

General Notes

1. Vendor to tape a copy of this drawing to the outside of the water heater compartment door.

F E

R

3060-E-SG

SEAT

W/H

30603060

B A

BEDROOM #1

TPS

CLOSET

D R

Y E

R W

A S

H E

R

3060-E-SG

NIGHT-

STAND

C O

F F

B

L E

TABLE

END-

PANTRY

NIGHT-

STAND

KITCHEN

BEDROOM #2

P.BOX

LIVING & DINING

ROOM

10 9

5 6 7

222324

UFAS MANEUVERING CLEARANCES AT DOORS AND TURNING SPACE CONFIGURATION LAYOUT

D R

E S

S E

R

D R

E S

S E

R

EXTERIOR

A/C UNIT

F

FEMA SUPPLIED

DEHUMIDIFIER

R E

F E

R

3060-E-SG

SEAT

W/H

30603060

B A

BEDROOM #1

TPS

CLOSET

D R

Y E

R W

A S

H E

R

3060-E-SG

NIGHT-

STAND

C O

F F

B

L E

TABLE

END-

PANTRY

NIGHT-

STAND

KITCHEN

BEDROOM #2

P.BOX

LIVING & DINING

ROOM

36" PATH

36" PATH

36" PATH

KITCHEN

UFAS CLEAR FLOOR SPACE LAYOUT

D R

E S

S E

R

D R

E S

S E

R

EXTERIOR

A/C UNIT

F

FEMA SUPPLIED

DEHUMIDIFIER

SEE NOTE 4

6/28/2019FEMA Manufactured Housing Units

Federal Emergency Management Agency

14' WIDE MHU (FURNACE)

DATE:

SCALE:

COMPANY: VERSION:

14F2-5

DRAWING NO.

UFAS LAYOUT

Location UFAS Section and/or Figure References Exterior Doors

1. Front Door - Hall to Front Door 4.13.6 - Figure b - Push side

2. Front Door - Living Room to Front Door 4.13.6 - Figure c - Push side

4. Rear Door - Kitchen to Rear Door 4.13.6 - Figure b - Push side Bedroom 1

5. Hallway to Bedroom 1 4.13.6 - Figure a - Push side - See Note 1.

6. Bedroom 1 to Hallway 4.13.6 - Figure a - Pull side

7. Bedroom 1 to Closet 4.13.6 - Figure a - Pull side

8. Turning Space Configuration 4.2.3 - Figure a - 60” Diameter Space

Bath 1

9. Bedroom/Hallway to Bath 1 4.13.6 - Figure c - Push side

10. Kitchen/Hallway to Bath 1 4.13.6 - Figure b - Push side

11. Bath 1 to Hallway 4.13.6 - Figure a - Pull side

12. Turning Space Configuration 4.2.3 - Figure a - 60” Diameter Space

13. Lavatory Clear Floor Space 4.19.3 - 30” x 48”

14. Tub/Shower Clear Floor Space 4.20.2 - Figure 33(a) - 30” x 60”

15. Toilet Clear Floor Space 4.16.2 - Figure 28 - 56” x 60”

Living Room

16. Turning Space Configuration 4.2.3 - Figure b - T-Shaped Space

Location UFAS Section and/or Figure References Kitchen

17. Turning Space Configuration 4.2.3 - Figure a - 60” Diameter Space

18. Range Clear Floor Space 4.34.6.2 - 30” x 48”

19. Sink Clear Floor Space 4.34.6.5(7) - 30” x 48”

20. Counter Work Surface Clear Floor Space 4.34.6.2 - 30” x 48”

21. Refrigerator Clear Floor Space 4.34.6.2 - 30” x 48” Bedroom 2

22. Kitchen to Bedroom 2 4.13.6 - Figure a - Push side - See Note 1.

23. Bedroom 2 to Kitchen 4.13.6 - Figure a - Pull side

24. Bedroom 2 to Closet 4.13.6 - Figure a - Pull side

25. Turning Space Configuration 4.2.3 - Figure a - 60” Diameter Space

UFAS Maneuvering Clearances at Doors and Egress Chart - 3 Bedroom

3. Rear Door - Bedroom 2 to Rear Door 4.13.6 - Figure c - Push side

Notes

1. Door does not have closer.

2. The minimum clear width for a single wheelchair continuous path is 36” (UFAS 4.2.1).

3. All appliances shall be UFAS Compliant.

4. 50% of shelf space shall be below 54" reach range (UFAS 4.25.3)

5. Location of tub/shower seat shall be within UFAS forward reach range of tub/shower controls (UFAS 4.20.3 and Fig. 5(a)).)

F E

R

SEAT

W/H

D R

Y E

R W

A S

H E

R

PANTRY

P.BOX

SS

S

S

GFCI-WP

NOAA

S

TV

WP-16

SS

19-GFCI

SA

7-GFCI

SSS

Back box for exterior alarm.

S

GFCI-WP

141717

GFCI-WP 6

GFCI

GFCI

GFCI

GFCI

GFCI

GFCI

RH-16

TPS Annunciator Panel

SA

SS

WP-16

S

S

TV

NOAA

SA

FE

T

H.T.

S

J

Service entrance J-Box

GFCI-WP

GFCI

TV

EXTERIOR

A/C UNIT

F

S

Single outlet recept for refrigerator

6/28/2019FEMA Manufactured Housing Units

Federal Emergency Management Agency

14' WIDE MHU (FURNACE)

DATE:

SCALE:

COMPANY: VERSION:

Cir. Purpose Type Wire Size Amps Pole

Bedroom 1 14-2 15 1

2 Bedroom 2 15 1

3 Bedroom 3 15 1

4 Kitchen 20 1

5 Kitchen 1

6 Ext. Recep 1

7 Washer 1

8 Dryer 30 2

9 Electric Range

10 Water Heater

11 A/C

12 Smoke Detectors 15 1

13 Furnace

GFCI

14-2

14-2

12-2

10-3

Per MFR. Specs.

14-3

20GFCI 12-2

20GFCI 12-2

20GFCI 12-2

Per MFR. Specs.

Per MFR. Specs.

14 Living Room 15 114-2

15 TPS System

16 Lights/Recep 15 114-2

17 Dining Room 20 114-2

18 Refrigerator 15 114-2

Per MFR. Specs.

Per MFR. Specs.

19 Bath Receps / Heat Tape 20 114-2

GFCI

GFCI

J

WP

Sym. Description

110 volt duplex recep-wall mounted

110 volt duplex-GFCI protected recept

220 volt recept-wall mounted

Light Fixture - Ceiling Mounted

Light Fixture - Wall mounted

Exhaust fan - Light Combo

Distribution panel board - 200 amp

Exterior light fixture - weather proof

Junction Box

TV

FE

S

S

NOAA

T

Smoke Alarm w/ Strobe Light - wired in series

Telephone Recept

TV Outlet

Fire Extinguisher

Switch

Switch - Three Way

Outlet for NOAA Weather radio

Thermostat

SA

Sym. Description

14F2-6

DRAWING NO.

ELECTRICAL PLAN

Electrical And Lighting Notes

1. The highest breaker in the panel box should be 48" high. Panel box bottom must be at least 24" from the floor.

2. The light bulbs shall be LED, equivalent to 60-watt incandescent bulbs, minimum 800 lumens, white in color, between 2,700 K and 4,100 K.

3. No glass shall be used in any of the lighting globes.

4. The exterior lights shall be stored in the refrigerator during transport.

5. Interconnected smoke alarms shall utilize the home's primary power source and shall have battery backup.

6. The center line of the switches and the top of the thermostat must be installed at no more than 48” above the finished floor.

7. Electrical outlets must be no lower than 18" above the floor to the center of the receptacle screw.

8. The junction box for the telephone and cable shall be located within 4' of the road side rear of the MHU.

9. Electric wiring may be done either through the floor or the ceiling.

10. The exterior service entrance junction box shall be rated NEMA 3 and minimum of 12” x 12” x 4”.

11. Service entrance junction shall be mounted to floor joist between the I-beam and sidewall.

12. Service entrance junction box to be located within 10' on the curb side rear of MHU.

13. The wiring from the service entrance junction box to service panel to be in seal-tight conduit.

14. Bathroom exhaust fan with light to be 75 cfm with an integrated timer to allow fan to operate sixty minutes minimum prior to turning off.

15. Kitchen range hood exhaust fan with a white light shall be a minimum 100 cfm exhaust fan, with separate switches.

16. Bathroom and kitchen exhaust fans shall vent directly to the outside.

17. Ceiling lights shall have 2 LED bulbs.

18. The bathroom vanity light shall be wall mounted with 3 LED bulbs.

19. The circuit breaker(s) providing power to the TPS unit shall be equipped with a UL-listed locking device that can secure the breaker(s) in the ON position. Devices shall be installed set to the ON position and shall be equipped with an appropriate lock that fits inside the panel board.

20. Kitchen countertop receptacles and switches must be furred out to be 24" (max) from front edge of countertop, and no more than 44" to the top of the switches or receptacles above finished floor.

21. See TPS closet and TPS closet elevations for electrical locations in Appendix A.

Legend

CUT OFF VALVE LOCATION

3/4" LINE (HOT)

1/2" LINE (HOT)

3/4" LINE (COLD)

1/2" LINE (COLD)

ADJACENT PIPE SIZES.

FITTING SIZES TO CORRESPOND TO

ALL SIZING OF PIPE + OR -, MUST

MEET OR EXCEED ANY APPLICABLE

2)

CODES.

1)

Notes

W/H

Washer

K.Sink

Inlet

Master Shutoff

Stool

Tub

Lav

Low point drain in water lines with shut-off valves

Hose Bib

NTS

6/28/2019FEMA Manufactured Housing Units

Federal Emergency Management Agency

14' WIDE MHU (FURNACE)

DATE:

SCALE:

COMPANY: VERSION:

14F2-7

DRAWING NO.

WATER LINES

Water Supply System Notes

1. The water supply lines shall be Cross-linked polyethylene (PEX) or chlorinated polyvinyl chlorine (CPVC) and comply with the requirements of 24 CFR 3280.

2. All water lines shall be 1/2” unless noted.

3. The water supply inlet shall be 3/4” and have a brass quarter turn ball valve.

4. The water supply inlet shall extend not more than 6” below the bottom board.

5. The water supply inlet shall be located within 12” of the curb side of the home.

6. The water supply inlet shall not be located under an exterior door.

7. Individual shut off valves shall be located on each water line at each fixture, except at the tub/shower or shower.

8. All water line floor penetrations shall be caulked or foamed. Caulk or foam shall be acceptable to be in contact with the water line material.

9. Adequately sized access panels (12” x 12” min) shall be located in the walls at all points where concealed plumbing slip joints exist. The access panels shall match the wall color and finish. Access panels shall be unobstructed and accessible for inspection and repair.

10. The MHU shall be equipped with a frost-free hose bib located near the main water supply inlet. It shall not be located under an exterior door.

11. Low point drain in water lines with shut-off valves shall be located above bottom board and insulation. Vendor to provide access panel, labeled "Low Point Drain".

SANITARY TEE

LONG TURN TY

CLEAN OUT PLUG

CAP & CHAIN

22.5° ELL

45° ELL

REDUCER BUSHING

90° CLOSET ST. ELL

FITTING SIZES CORRESPOND TO ADJACENT PIPE SIZES.

DOUBLE LINES REPRESENT 3" PIPE.

DARK (THICK) LINES REPRESENT 2" PIPE;

SINGLE (THIN) LINES REPRESENT 1-1/2" PIPE;

DWV FITTING LEGEND

P-TRAP DIRECTIONS MAY VARY.3)

2)

1)

MECHANICAL VENT

90° LONG TURN ELL

DOUBLE SANITARY TEE

90° LONG TURN ST. ELL

LK

P-TRAP

COUPLING

NM

T

R

S

Q

O P

45° Y

DOUBLE ELL

F

JI

H

B

D

E

G

A

C

To Sewer

A

F

M

L

F

K.Sink

K

A

B

C

H

Washer

L

M

F

F

K

Stool

D

H

B

Tub

A

F

M

(Stool Vent)

H

F

M

L

F

Lav

A

K

SEE NOTES 5 THRU 7

Notes

NTS

6/28/2019FEMA Manufactured Housing Units

Federal Emergency Management Agency

14' WIDE MHU (FURNACE)

DATE:

SCALE:

COMPANY: VERSION:

14F2-8

DRAWING NO.

DRAIN LINES

Drain System General Notes

1. Drain lines shall be ABS or PVC and comply with the requirements of 24 CFR 3280.

2. All drain lines shall be 1 ½” diameter unless noted.

3. The drain line system shall be accessible without removing the axles and wheels.

4. All drain line floor penetrations, except at tub/shower and shower floor penetrations shall be caulked or foamed. Caulk or foam shall be acceptable to be in contact with the drain line material.

5. The drain line which shall run below the floor and above the bottom board to the place of drain outlet not less than two feet (2') but not more than three feet (3') in front of the axle group.

6. The drain line outlet shall protrude at least six inches (6”), but not more than eight inches (8”), below the bottom board.

7. The drain line outlet shall have a threaded end and will be capped with a removable plastic cap and chain or strap.

F E

R

3060-E-SG

SEAT

W/H

30603060

D R

Y E

R W

A S

H E

R

3060-E-SG

PANTRY

P.BOX

BATH #1

BEDROOM #1

TPS

CLOSET

KITCHEN

BEDROOM #2

LIVING & DINING

ROOM

EXTERIOR

A/C UNIT

F

6'-0"

15'-4"19'-9

4"

26'-3"

44'-4"

38'-0"

6/28/2019FEMA Manufactured Housing Units

Federal Emergency Management Agency

14' WIDE MHU (FURNACE)

DATE:

SCALE:

COMPANY: VERSION:

Heating

HVAC PACKAGES UNIT SPECIFICATIONS

Cooling (Min. 1.5-Ton Air Conditioner)

14F2-9

DRAWING NO.

OVERHEAD DUCT LAYOUT

HVAC DESIGN AND

(10 KW Electric Furnace)

HVAC Split Furnace / AC Notes

1. The furnace shall be at least a ninety-five percent (95%) efficient electric furnace (central heating system) capable of maintaining an average temperature of seventy degrees

Fahrenheit (70°F) in the MHU.

2. The MHU shall be equipped with a specifically engineered HVAC split furnace /AC system based on the size and intended use of the MHU, in accordance with 24 CFR 3280.506, that is compatible with the HVAC split furnace /AC system size.

3. The furnace shall also be built or equipped for the installation of a split type air conditioner and have enclosed space in water heater/furnace compartment for an A-coil evaporator unit, and with a 4-wire thermostat completely wired and installed.

4. A vibration damping pad shall be placed between the condensing unit and the mounting platform.

5. A 1” ratchet strap with 500 lb. capacity shall be installed around the outside of the condenser unit and bracket extension for transportation.

6. Air conditioning lines shall be pre-charged in the factory per manufacturers specifications and shall not have any leaks.

7. Furnace return air return grill shall be sized per furnace manufacturer's installation instructions.

8. Duct penetrations thru ceiling board shall be sealed.

HVAC General Notes

1. See FEMA specifications for programable and configurable thermostat requirements.

2. Duct system shall be constructed of class 0 or class 1 circular insulated flex ductwork or equal. All ducts to be insulated with a minimum of R-4 insulation.

3. Metal supply register sizes as shown on duct layout.

4. All supply ducts shall be in the roof attic space.

5. All supply duct seams and fasteners shall be sealed with UL-181A or UL-181B listed duct tape.

6. The manufacturer shall provide a duct pressure test report (See FEMA Spec for testing procedure) for each MHU duct system showing duct leakage of 5 percent or less prior to FEMA acceptance of the MHU.

7. No construction debris or sawdust shall be left in the duct system.

8. Undercutting of interior doors is not permitted.

9. Return air grilles shall be sized per 24 CFR 3280.715(b)(4).

10. Return air grilles shall be located above interior doors.

11. When the sprinkler system obstructs the return air grille, it may be located in the interior door or interior wall.

ANGLE RAIN DIVERTER OVER DOOR

EXTERIOR LIGHT

FRONT DOOR

TPS DOOR BACK DOOR

PEEP HOLES

PEEP HOLES

ANGLE RAIN DIVERTER OVER DOOR

EXTERIOR LIGHT

EXTERIOR ALARM DEVICE BOX w/ COVER PLATE

RIDGE VENT (TYP.)

M

X

O

T

P

F

R

I D

G

V

N

T

14'-0" EAVE TO EAVE

13'-6"

INTERIOR FLOOR LINE

INTERIOR FLOOR LINE

M

T

R

I D

N

T

14'-0" EAVE TO EAVE

13'-6"

VINYL SIDING BELOW DOORS TO COVER 2X8 PERIMETER RAILS.

FRONT DOOR SIDE ELEVATION

HITCH END ELEVATION TAIL END ELEVATION

BACK DOOR SIDE ELEVATION

3"3"3"3"

HUD LABEL: APPROX. 12" UP

FROM FLOOR AND 12" FROM

ROADSIDE.

EXTERIOR RECEPTACLE (GFCI)

RIDGE VENT (TYP.)

EXTERIOR RECEPTACLE (GFCI)

RANGE VENT

OUTSIDE

CONDENSER

UNIT WITH

PROTECTIVE

COVER.

OUTSIDE

CONDENSER

UNIT WITH

PROTECTIVE

COVER.

SERVICE ENTRANCE

JUNCTION BOX

EXTERIOR RECEPTCLE (GCFI)

(6" ABOVE FINISHED FLOOR)

HOSE BIB

TRANSPONDER

OSB WIND DIVERTER

TITLE:

Scale: 1/8" = 1'-0"

Date: 6/28/2019FEMA Manufactured Housing Units

Federal Emergency Management Agency

14' WIDE MHU (FURNACE)

14F2-10

DRAWING NO.

ELEVATIONS

Exterior Finishes Notes

1. Siding shall be light gray vinyl.

2. Siding shall be double 4" lap.

3. Siding shall be approved for HUD Wind Zone 3 requirements.

4. The manufacturer shall provide a transponder sled. See Appendix A.

5. The sled shall be painted with a powder coat paint to match the exterior color of the MHU or White.

6. The transponder sled shall be made out of sheet metal.

25'-9

2"

48 48

4'-0"8'-0"50'-8"

50'-8"

48 4848 48

20'-0" 16'-0" 12'-0"

25'-1"

28'-7"

373737204848

16'-0" INSTALL TIRE BLOW-OUT

PROTECTION IN THIS AREA (BOTH SIDES)

31'-8"34'-9"37'-10"

42'-8"

46'-8"

26112611261126

27'-11

2"

28'-10

2"

31'-0

2"

31'-11

2"

34'-1

2"

35'-0

2"

37'-2

2"

- SPRING HANGER

- SISTER BEAM

25'-1" START SISTER BEAM AND BLOW-OUT PROTECTION

S

I D

E

A

Drawing Notes

FRAME CLIP DETAIL

(SAME ON BOTH MAIN I-BEAMS)

**DIMS ARE PULLED FROM END OF HEADER BEAM.

**BE SURE TO VERIFY FLOOR JOIST LAYOUT TO MATCH CLIPS TO JOISTS.

50'-8"

FRAME CLIPS IN AXLE AREA ARE LOCATED ON INSIDE OF SISTER BEAM AS SHOWN.

1'-4"

2'-8"

5'-4"

6'-8"

9'-7" (MOVED JOIST)

10'-8"

13'-4"

14'-5"

(MOVED JOIST)

21'-4"25'-4"28'-0"

29'-4" 22'-8"

30'-8"

33'-4"

34'-8"

40'-0"

LONGITUDINAL

BRACKET

LONGITUDINAL

BRACKET

4 TYP. HOLE SPACING

FRONT AND REAR HEADER SHEARWALL LAG BOLT SPACING

A-FRAME

RE-INFORCEMENT

CENTERED AND

UNDER FRONT

HEADER

DETAIL "B"

DETAIL "C", SEE CHASSIS DETAILS

SEE CHASSIS DETAILS, DETAIL "A"

3'-6"

12" X 10.8# I-BEAM HEADER

12" X 10.8# I-BEAM HEADER

LONGITUDINAL BRACKETS LONGITUDINAL BRACKETS

SEE APPENDIX A, PAGE A-40

13 Ga. "C" CROSSMEMBER

1-1/2"x3"x1-1/2" X 2' LONG.

(SPLIT FURNACE / AC MHU ONLY)

24'-0"

16'-0" LENGTH OF SISTER BEAM (TYP.)

96 LONGITUDINAL BRACKET

LONGITUDINAL

BRACKET

32'-0"

36'-0"

37'-4"

38'-8"

41'-4"

44'-0"

45'-4"

48'-0"

49'-4"

17'-5

2" CENTER OF AXLES

33'-2

2" CENTER OF AXLES (65.5% OF FRAME LENGTH)

26'-8"

38'-1

2"

40'-3

2"

41'-0"

17'-5

4"

18'-9

4"

17'-2

4"

18'-6

4"

TITLE:

Scale: 1/8" = 1'-0"

Date: 6/28/2019FEMA Manufactured Housing Units

Federal Emergency Management Agency

14' WIDE MHU (FURNACE)

14F2-11.1

DRAWING NO.

CHASSIS

Chassis Frame Notes

1. All metal-to-metal contact with 1/8” fillet weld minimum.

2. Floor shall be lagged to frame with frame clip, Fastec 9mm x 76mm listed lags or lags equivalent in size and strength at each joist and outrigger tip.

Alternate lags must be reviewed and approved by FEMA or their designee.

3. Clips shall be welded to the I-beam.

4. All parts of the chassis including added/welded parts shall be completely coated with waterproof paint.

5. Tires shall be new, 14.5” rim diameter, 14 ply with “G” load range.

6. Wheels and tires shall meet or exceed the axle rating and be rated for continuous speeds of 65 mph or greater.

7. All axles shall be new.

8. All axles shall be brake axles.

9. A valve stem cover shall be present on every tire.

10. The serial number shall be permanently stamped to the front header to comply with 3280.6. In addition, the serial number shall be painted with rust resistance contrasting color paint, 2 inches (2”) tall on the front header.

11. Rims, bolts, nuts, or other related tire-mounting hardware shall be new.

12. Longitudinal brackets shall be installed at 8'-0” and 16'-0" maximum from each end of the home.

13. Spring hangers shall be multi-leaf.

14. All rims shall be the same color.

15. Maximum typical pier spacing along main I-beams @ 8'-0” o.c. Typical pier load = 6,400 lbs.

16. Manufacturer to place permanent indicators (paint or label) on each I-Beam @ 2'-0" from each end, 12'-0" on center max, and at door jambs for location temporary piers for storage.

17. Longitudinal bracket slot to face towards closest end of home.

Frame Specs

· Main I-Beam: 12" x 10.8#

· Front and Rear Headers: 12" x 10.8#

· Crossmember: 13 Ga. C or Z, 1-1/2" x 3" x 1-1/2"x13 Ga.

· Outriggers: 9" Min Depth at I-Beam tapered to 1" , 13 Ga min., C or Z type, with 1-1/2" flange top and bottom.

· Frame Clips: 1" x 1-1/2" x 12 Ga.

Hitch Specs

· See Chassis Details, Details "A"

Welding Specs

1. All welds to be a minimum 1/8" unless otherwise noted. Weld beads can be concave in application as long as the weld size is met.

2. Coupler and Jack shall be welded per manufacturer's installation instructions.

3. I-Beam splice plate shall be 4" wide x height of I-Beam minus 1-1/4" x 13 GA.

Splice plate can be offset +/- 1/4". Weld shall be full width of splice plate.

Splice plate only required on one side of I-Beam.

4. Sister I-Beam shall be welded with 1/8" butt welds 2" long at 24" o.c. top and bottom of I-beam

5. All weld lengths stated or shown are minimum lengths and shall have a tolerance of minus 1/4" (except spring hangers). Weld lengths that are not noted shall be full length.

I-BEAM 12" X 10.8#

DRAWBAR CROSSMEMBER I-BEAM 12" X 10.8# REINFORCEMENT

UNDER FRONT HEADER AND CENTERED BETWEEN FRONT HEADER AND TONGUE

VENTURE 2-5/16" - 60 DEGREE, 10,000LB COUPLER OR EQUIVALENT

JACK - VENTURE TOP MOUNT,

10,000LB GALVANIZED OR EQUIVALENT.

7-3/8" X 4" NOSE PLATE

1" x 1-1/2" X 12GA FRAME CLIP

1/8" x 1-1/2" FILLET WELD TO TOP

FLANGE OF I-BEAM.

9" x 1.5" x 1.5" x 13 Ga

FULL LENGTH OUTRIGGER

1-1/2" x 1-1/2" x 13"L x 13 GA. ANGLE

" x 1"L FILLET WELD TO I-BEAM

AND CROSSMEMBER

FRONT AND REAR I-BEAM HEADERS - 12" X 10.8#

CROSSMEMBER

C OR Z 1-1/2" x 3" x 1-1/2"

13 GA. @ 48" O.C.

1 1/21 1/2

BOTTOM OF FRAME I-BEAM

1/8" X 2" LONG FILLET WELD

3/4 1 1/2 3/4

DIA. 9/16" HOLE

DETAIL - SEE SLOT

A

A

1 1/21 1/2

1 1/2 3/43/4

DETAIL "A-A"

SLOT DETAIL

1 5/8

13/16

DIA. 9/16" HOLE

DIA. 9/16" HOLE

DIA. 9/16" HOLE

F

U

L

L

M

A

X

M

A

X

N

O

W

E

L

D

1/4" FILLET WELD

EACH SIDE

Notes

1. Thickness is 4 gauge.

2. Vendor to assure all spring hangers are 90° to I-Beam.

3. Shoulder bolts to be torqued per axle manufacturer requirements

(Approximately 30 to 50 ft. lbs).

Leaf Spring to move freely in hanger.

I-BEAM FLANGE

LOOKING UP AT SPRING HANGER

SPRING HANGER

SPRING

HANGER

LEAF

SPRING

EQUALIZER

AXLE

U-BOLTS

LEAF

SPRING

SHACKLE LINK

WITH BOLTS

CENTER SPRING

HANGER

FRAME I-BEAM

TITLE:

FEMA Manufactured Housing Units

Federal Emergency Management Agency

14' WIDE MHU (FURNACE)

1/8" = 1'-0"

6/28/2019

VERSION:DATE:

SCALE:

COMPANY:

14F2-11.2

DRAWING NO.

CHASSIS DETAILS

DETAIL C: LONGITUDINAL TIE-DOWN BRACKET

DETAIL B: AXLE HANGER

DETAIL A: HITCH ASSEMBLY

DETAIL D: EQUALIZER & SHACKLE LINK FASTENING

Notes

1. Shoulder bolts are to be used at all equalizer and shackle link locations.

2. Shoulder bolts shall be torqued per axle manufacturer requirements.

(Approximately 30 to 50 ft. lbs.)

3. Equalizer and shackle links are to move freely after shoulder bolts have been torqued.

4. Axle U-bolts shall be torqued per axle manufacturer requirements

(Approximately 70 to 95 ft. lbs.)

LONGITUDINAL TIE-DOWN BRACKET (12Ga. MIN.) SHALL HAVE

3150 LB WORKING LOAD CAPACITY.

50'-8"

S

H E

A R

W A

L L

J O

I S

T S

S

H E

A R

W A

L L

J O

I S

T S

D

O U

B L

E

J O

I S

T

D

O U

B L

E

J O

I S

T

D

O U

B L

E

J O

I S

T

M

O V

D

J

I S

T

M

O V

J

I S

T

D

R Y

N

T

L

O C

A T

I O

N

2 - 2"x6"x18" TREATED LUMBER BACKERS FOR MOUNTING SERVICE ENTRANCE JUNCTION BOX.

FASTEN THRU BOTTOM BOARD INTO JOISTS ABOVE WITH 2-#8x3" STAINLESS STEEL OR

HOT DIPPED GALVANIZED(GI85) SCREWS EACH END.

6/28/2019FEMA Manufactured Housing Units

Federal Emergency Management Agency

14' WIDE MHU (FURNACE)

DATE:

SCALE:

COMPANY: VERSION:

14F2-12

DRAWING NO.

FLOOR FRAMING LAYOUT

Floor Framing Notes

1. The floor joists shall be 2 x 8 #2 SPF 16” o.c.

2. Edge rails shall be 2 x 8 #2 SPF.

3. Edge rail splice 4 x 5 x 20 GA metal connector plate on each side, or 2 x 8 x minimum 6" each side of joint centered +/- 1”, to be fastened with 7/16 x 2 ½ x 15 GA staples or .131 x 3” PD nails (8) each side of edge rail, with minimum 80% PVA coverage.

Floor Insulation Notes

1. The insulation shall have a flame spread of 25 or less and a smoke develop of 450 or less.

2. The floor insulation shall be a minimum of R-26 fiberglass blanket insulation. One full batt, one additional full width batt between the I-beams, and one additional 16” wide batt between joist outside of I-beams.

Bottom Board Notes

1. All penetrations sealed per bottom board manufacturer's installation instructions.

2. Bottom board shall be a minimum of twenty (20) mil thickness.

3. Multiple layers of acceptable material per 3280.305(g)(6) may be used.

4. Fasten bottom board to perimeter framing per manufacturer's installation instructions.

Floor joists to rim joist

Multiple joists (to each other)

7/16 x 2-1/2 x 15Ga staple

OR 0.131 x 3" Nail

7/16 x 2-1/2 x 15Ga staple

OR 0.131 x 3" Nail

7 each

5 each

12" o.c.

12" o.c.

DESCRIPTION FASTENER QTY

FASTENING SCHEDULE - FLOOR FRAMING

(80% PVA glue coverage) . Jun 28, 2019

TOILET

W/H DRAIN

LAV

A

B

C

D

1234567

1234567

34567

1234567

42'-6" PHONE & TV WIRE

37'-11" KIT. SINK

37'-7

2" KIT. SINK

24'-10" P.BOX

20'-7" W/H

18'-7

4" WASHER

8'-2

2" LAV

18'-3" DRYER DUCT

18'-7

4" DRYER WIRE

20'-9" TPS CLOSET DRAIN Ø1"

15'-5

4" TOILET SUPPLY

14'-11" TOILET DRAIN

8'-10" TUB P-TRAP

9'-5" TUB SUPPLY

8'-3

2" TUB DRAIN

7'-10

4" PHONE & TV WIRE

P

H O

N E

T

V

24'-8" P.BOX

24'-6" P.BOX

37'-11" K. SINK

37'-7

2" K. SINK

30'-9" RANGE WIRE

W/H SUPPLY

21'-8

2" TV WIRE

21'-5

2" TV WIRE

33'-4" DEHUMIDIFIER DRAIN Ø2"

PHONE WIRE

TV WIRE

6/28/2019FEMA Manufactured Housing Units

Federal Emergency Management Agency

14' WIDE MHU (FURNACE)

DATE:

SCALE:

COMPANY: VERSION:

Decking to Joists 7/16 x 1-3/4 x 16Ga staple

OR 0.092 x 2" Nail

4" edges / 6" field w/ glue

6" edges / 10" field w/ glue

DESCRIPTION FASTENER APPLICATION

FASTENING SCHEDULE - FLOOR DECKING

14F2-13

DRAWING NO.

FLOOR DECKING LAYOUT

Floor Decking Notes

1. The floor decking shall be 23/32" Tongue and Grove (T&G) OSB or

APA-rated plywood 24/0 index, laid out as shown on decking plan.

2. Decking shall be Exposure 1 rated.

3. Long edges of the panel shall be T&G installed perpendicular to the floor joists.

4. PVA (polyvinyl acetate) or equal shall be used as adhesive with 80% coverage.

5. Vinyl flooring shall be installed on all interior floors of the home installed per manufacturer's instructions.

F E

R

3060-E-SG

SEAT

W/H

30603060

B A

BEDROOM #1

TPS

CLOSET

D R

Y E

R W

A S

H E

R

3060-E-SG

PANTRY

KITCHEN

BEDROOM #2

P.BOX

P1

P2

P3

P4

P6

P7

P10

P8

P5

P9

P11

P13

P12

E1

270 37

2 HDR

LIVING & DINING

ROOM

E2

S2

S1

H

D R

H D

R

H D

R

H

D R

H D

R

BACKPANEL

BEFORE P5

IS SET

EXTERIOR

A/C UNIT

F

2" x 4" x 20 Ga. Metal Connector

Plate, one each side

Min. 2"x6"x10" block centered over splice ±1" and fastened with (6)-7/16" x 2-1/2" x

15Ga staples each end of splice.

Min. 2"x6"x10" block centered over splice ±1" and fastened with (6)-7/16" x 2-1/2" x 15Ga staples each end of splice.

2" x 4" x 20 Ga. Metal Connector

Plate, one each side

TOP PLATE SPLICE

BOTTOM PLATE SPLICE

FASTENING SCHEDULE - INTERIOR WALLS

STUD TO TOP/BOTTOM PLATE

FASTENER APPLICATION

DOOR HEADER TO STUD

15Ga. x 7/16" x 2-1/2" STAPLES or 0.131" X 3" NAIL

3 EACH

2 EACH

BOTTOM PLATE TO FLOOR

TOP PLATE TO CEILING

INTO LAYFLAT

INTO TRUSS

GYPSUM TO STUDS

STUD TO STUD

LAYFLAT TO TOP/BOTTOM PLATE

3 EACH

2 EACH

DESCRIPTION

15Ga. x 7/16" x 2-1/2" STAPLES or 0.131" X 3" NAIL

12" O.C.

12" O.C.

or #8 x 3" WOOD SCREW

12" O.C.

12" O.C.

GYPSUM TO STUDS, 80% PVA GLUE

12" O.C.

12" O.C.

2 EACH

12" O.C.

ALTERNATE GYPSUM TO STUDS

100% ONE PART URETHANE GLUE

19Ga. x 3/16" x 1-1/4" STAPLES or DRYWALL SCREWS

6" EDGES

6" EDGES

19Ga. x 3/16" x 1-1/4" STAPLES or DRYWALL SCREWS

6" Edges / 12" Field

6" Edges / 12" Field

As per product manufacturer's instructions

15Ga. x 7/16" x 2-1/2" STAPLES or 0.131" X 3" NAIL

15Ga. x 7/16" x 2-1/2" STAPLES or 0.131" X 3" NAIL

INTERIOR WALL TO SIDEWALL #8 SCREWS, MIN. 1" PENETRATION 16" O.C.

INTERIOR WALL TO INTERIOR WALL .131" NAIL, MIN. 1" PENTRATION 16" O.C.

or #8 x 3" WOOD SCREW

6" O.C.

or #8 x 3" WOOD SCREW

15Ga. x 7/16" x 2-1/2" STAPLES or 0.131" X 3" NAIL

12" O.C.

15Ga. x 7/16" x 2-1/2" STAPLES or 0.131" X 3" NAIL

BACKERS TO STUD

15Ga. x 7/16" x 2-1/2" STAPLES

(END GRAIN ONLY)

OR .131" X 3" NAIL (END GRAIN ONLY OR TOED)

6 EACH

3 EACH

6/28/2019FEMA Manufactured Housing Units

Federal Emergency Management Agency

14' WIDE MHU (FURNACE)

DATE:

SCALE:

COMPANY: VERSION:

14F2-14

DRAWING NO.

BACK PANEL LAYOUT (HORIZONTAL)

INTERIOR WALL AND

General Notes

1. Gypsum to be jointed above all doors in line with jambs.

F E

R

3060-E-SG

SEAT

W/H

30603060

B A

BEDROOM #1

TPS

CLOSET

D R

Y E

R W

A S

H E

R

3060-E-SG

PANTRY

KITCHEN

BEDROOM #2

P.BOX

P1

P2

P3

P4

P6

P7

P10

P8

P5

P9

P11

P13

P12

E1

LIVING & DINING

ROOM

24220

E2

S2

S1

EXTERIOR

A/C UNIT

F

2" x 4" x 20 Ga. Metal Connector

Plate, one each side

Min. 2"x6"x10" block centered over splice ±1" and fastened with (6)-7/16" x 2-1/2" x

15Ga staples each end of splice.

Min. 2"x6"x10" block centered over splice ±1" and fastened with (6)-7/16" x 2-1/2" x 15Ga staples each end of splice.

2" x 4" x 20 Ga. Metal Connector

Plate, one each side

TOP PLATE SPLICE

BOTTOM PLATE SPLICE

FASTENING SCHEDULE - INTERIOR WALLS

STUD TO TOP/BOTTOM PLATE

FASTENER APPLICATION

DOOR HEADER TO STUD

15Ga. x 7/16" x 2-1/2" STAPLES or 0.131" X 3" NAIL

3 EACH

2 EACH

BOTTOM PLATE TO FLOOR

TOP PLATE TO CEILING

INTO LAYFLAT

INTO TRUSS

GYPSUM TO STUDS

STUD TO STUD

LAYFLAT TO TOP/BOTTOM PLATE

3 EACH

2 EACH

DESCRIPTION

15Ga. x 7/16" x 2-1/2" STAPLES or 0.131" X 3" NAIL

12" O.C.

12" O.C.

or #8 x 3" WOOD SCREW

12" O.C.

12" O.C.

GYPSUM TO STUDS, 80% PVA GLUE

12" O.C.

12" O.C.

2 EACH

12" O.C.

ALTERNATE GYPSUM TO STUDS

100% ONE PART URETHANE GLUE

19Ga. x 3/16" x 1-1/4" STAPLES or DRYWALL SCREWS

6" EDGES

6" EDGES

19Ga. x 3/16" x 1-1/4" STAPLES or DRYWALL SCREWS

6" Edges / 12" Field

6" Edges / 12" Field

As per product manufacturer's instructions

15Ga. x 7/16" x 2-1/2" STAPLES or 0.131" X 3" NAIL

15Ga. x 7/16" x 2-1/2" STAPLES or 0.131" X 3" NAIL

INTERIOR WALL TO SIDEWALL #8 SCREWS, MIN. 1" PENETRATION 16" O.C.

INTERIOR WALL TO INTERIOR WALL .131" NAIL, MIN. 1" PENTRATION 16" O.C.

or #8 x 3" WOOD SCREW

6" O.C.

or #8 x 3" WOOD SCREW

15Ga. x 7/16" x 2-1/2" STAPLES or 0.131" X 3" NAIL

12" O.C.

15Ga. x 7/16" x 2-1/2" STAPLES or 0.131" X 3" NAIL

BACKERS TO STUD

15Ga. x 7/16" x 2-1/2" STAPLES

(END GRAIN ONLY)

OR .131" X 3" NAIL (END GRAIN ONLY OR TOED)

6/28/2019FEMA Manufactured Housing Units

Federal Emergency Management Agency

14' WIDE MHU (FURNACE)

DATE:

SCALE:

COMPANY: VERSION:

14F2-15

DRAWING NO.

PANEL LAYOUT (VERTICAL) - OPTIONAL

INTERIOR WALL AND BACK

General Notes

1. Gypsum to be jointed above all doors in line with jambs.

P1 x x

B

A C

K E

R

U

P

2X6 UP

S

H E

L F

S

H E

L F

2X6 UP

BED#1 CLO.

VERTICAL WALL BOARD PANEL BREAKS

6/28/2019FEMA Manufactured Housing Units

Federal Emergency Management Agency

14' WIDE MHU (FURNACE)

DATE:

SCALE:

COMPANY: VERSION:

1/2" = 1'-0"

14F2-16.1

DRAWING NO.

INTERIOR WALLS

Interior Wall Framing Notes

1. All interior walls are 2 x 3 (unless noted) #2 SPF at 16” maximum o.c., except washer wall.

2. Top plates to be 2 x 3 (unless noted) #2 SPF.

3. Bottom plates to be 1 x 3 (unless noted) #2 SPF.

4. Wall interiors shall be faced with ½” Gold Bond XP gypsum board with paint or equivalent installed per ASTM C840 and GA-216.

5. Gypsum board shall run vertically or horizontally along the entire height of wall interiors. See fastening schedule.

6. Wall panel trim (1/2” x 2”) shall be used to cover the gypsum panel joints. Trim fastened to only one of the two gypsum panels into stud, 10" O.C. fastener spacing.

7. Walls shall be sanded as needed to assure a smooth finish (level 3 finish minimum)

8. Paint shall be any latex paint. See FEMA spec.

25 1/2

P2

3 1/2

25 1/2

3 1/2

25 1/2

Federal Emergency Management Agency

14' WIDE MHU (FURNACE)

DATE:

SCALE:

COMPANY: VERSION:

1/2" = 1'-0"

14F2-16.2

DRAWING NO.

INTERIOR WALLS

Interior Wall Framing Notes

1. All interior walls are 2 x 3 (unless noted) #2 SPF at 16” maximum o.c., except washer wall.

2. Top plates to be 2 x 3 (unless noted) #2 SPF.

3. Bottom plates to be 1 x 3 (unless noted) #2 SPF.

4. Wall interiors shall be faced with ½” Gold Bond XP gypsum board with paint or equivalent installed per ASTM C840 and GA-216.

5. Gypsum board shall run vertically or horizontally along the entire height of wall interiors. See fastening schedule.

6. Wall panel trim (1/2” x 2”) shall be used to cover the gypsum panel joints. Trim fastened to only one of the two gypsum panels into stud, 10" O.C. fastener spacing.

7. Walls shall be sanded as needed to assure a smooth finish (level 3 finish minimum)

37 1/2

P3 x x

B

A C

K E

R

U

P x x

B

A C

K E

R

U

P

BACKER

DOWN

2X6

37 1/2

109 1/2

O R

I Z

O N

T A

L

P A

N E

L

S

I Z

E

I

P

L I C

A B

L E

O R

I Z

O N

T A

L

P A

N E

L

S

I Z

E

P

L I C

A B

L E

14 3/4

R.A.G. R.A.G.

14 3/8

1x

FILLER

2x BLOCK 18" MIN.

M

I N

NOTCH FOR SPRINKLER SYSTEM PIPE

-SEE APPENDIX A-30 DETAIL "B"

NOTCH FOR SPRINKLER

SYSTEM PIPE

2X6 SPRINKLER HEAD BACKER, SPRINKLER

HEAD BACKER LOCATION MAY VARY BASED

ON SPRINKLER DESIGN.

VERTICAL WALL BOARD PANEL BREAKS

48 48 13 1/2

37 1/2 3

BATHROOM #1

Federal Emergency Management Agency

14' WIDE MHU (FURNACE)

DATE:

SCALE:

COMPANY: VERSION:

1/4" = 1'-0"

14F2-16.3

DRAWING NO.

INTERIOR WALLS

Interior Wall Framing Notes

1. All interior walls are 2 x 3 (unless noted) #2 SPF at 16” maximum o.c., except washer wall.

2. Top plates to be 2 x 3 (unless noted) #2 SPF.

3. Bottom plates to be 1 x 3 (unless noted) #2 SPF.

4. Wall interiors shall be faced with ½” Gold Bond XP gypsum board with paint or equivalent installed per ASTM C840 and GA-216.

5. Gypsum board shall run vertically or horizontally along the entire height of wall interiors. See fastening schedule.

6. Wall panel trim (1/2” x 2”) shall be used to cover the gypsum panel joints. Trim fastened to only one of the two gypsum panels into stud, 10" O.C. fastener spacing.

7. Walls shall be sanded as needed to assure a smooth finish (level 3 finish minimum)

P4 x x

B

A C

K E

R

U

P

32 1/2

LEAVE THIS BAY OPEN FOR TUB VTR CHASE

14" x 14" ACCESS PANEL

(OATLEY 34056 OR EQUIVALENT)

CUT GYPSUM ACCESS PANELS ARE

NOT ACCEPTABLE.

32 1/2

BATH #1

Federal Emergency Management Agency

14' WIDE MHU (FURNACE)

DATE:

SCALE:

COMPANY: VERSION:

1/2" = 1'-0"

14F2-16.4

DRAWING NO.

INTERIOR WALLS

Interior Wall Framing Notes

1. All interior walls are 2 x 3 (unless noted) #2 SPF at 16” maximum o.c., except washer wall.

2. Top plates to be 2 x 3 (unless noted) #2 SPF.

3. Bottom plates to be 1 x 3 (unless noted) #2 SPF.

4. Wall interiors shall be faced with ½” Gold Bond XP gypsum board with paint or equivalent installed per ASTM C840 and GA-216.

5. Gypsum board shall run vertically or horizontally along the entire height of wall interiors. See fastening schedule.

6. Wall panel trim (1/2” x 2”) shall be used to cover the gypsum panel joints. Trim fastened to only one of the two gypsum panels into stud, 10" O.C. fastener spacing.

7. Walls shall be sanded as needed to assure a smooth finish (level 3 finish minimum)

P5

2X6 UP2X6 UP

2X6 UP2X6 UP

2X6 UP2X6 UP

S

I N

K

M

E D

I C

I N

E

C

A B

I N

E T

1x

FILLER

2x BLOCK 18" MIN.

M

I N

NOTCH FOR SPRINKLER SYSTEM PIPE

-SEE APPENDIX A-30 DETAIL "B"

Note

This wall not to be paneled on framing jig. To be paneled after floor plumbing installed.

Federal Emergency Management Agency

14' WIDE MHU (FURNACE)

DATE:

SCALE:

COMPANY: VERSION:

1/2" = 1'-0"

14F2-16.5

DRAWING NO.

INTERIOR WALLS

Interior Wall Framing Notes

1. All interior walls are 2 x 3 (unless noted) #2 SPF at 16” maximum o.c., except washer wall.

2. Top plates to be 2 x 3 (unless noted) #2 SPF.

3. Bottom plates to be 1 x 3 (unless noted) #2 SPF.

4. Wall interiors shall be faced with ½” Gold Bond XP gypsum board with paint or equivalent installed per ASTM C840 and GA-216.

5. Gypsum board shall run vertically or horizontally along the entire height of wall interiors. See fastening schedule.

6. Wall panel trim (1/2” x 2”) shall be used to cover the gypsum panel joints. Trim fastened to only one of the two gypsum panels into stud, 10" O.C. fastener spacing.

7. Walls shall be sanded as needed to assure a smooth finish (level 3 finish minimum)

37 1/2

P6 x x

B

A C

K E

R

U

P x x

B

A C

K E

R

U

P

51 1/2 42

37 1/2 21

3 1/2

O R

I Z

O N

T A

L

P A

N E

L

S

I Z

E

P

L I C

A B

L E

O R

I Z

O N

T A

L

P A

N E

L

S

I Z

E

P

L I C

A B

L E

2X6 SPRINKLER HEAD BACKER, SPRINKLER

HEAD BACKER LOCATION MAY VARY BASED

ON SPRINKLER DESIGN.

BACKER

UP & DOWN

2X6

4237 1/2

3 1/2

48 21

3 1/2

Federal Emergency Management Agency

14' WIDE MHU (FURNACE)

DATE:

SCALE:

COMPANY: VERSION:

1/4" = 1'-0"

14F2-16.6

DRAWING NO.

INTERIOR WALLS

Interior Wall Framing Notes

1. All interior walls are 2 x 3 (unless noted) #2 SPF at 16” maximum o.c., except washer wall.

2. Top plates to be 2 x 3 (unless noted) #2 SPF.

3. Bottom plates to be 1 x 3 (unless noted) #2 SPF.

4. Wall interiors shall be faced with ½” Gold Bond XP gypsum board with paint or equivalent installed per ASTM C840 and GA-216.

5. Gypsum board shall run vertically or horizontally along the entire height of wall interiors. See fastening schedule.

6. Wall panel trim (1/2” x 2”) shall be used to cover the gypsum panel joints. Trim fastened to only one of the two gypsum panels into stud, 10" O.C. fastener spacing.

7. Walls shall be sanded as needed to assure a smooth finish (level 3 finish minimum)

P7

BCKR

DOWN

2X6

BCKR

DOWN

2X6

DN

G R

B

R

1x

FILLER

2x BLOCK 18" MIN.

M

I N

NOTCH FOR SPRINKLER SYSTEM PIPE

-SEE APPENDIX A-30 DETAIL "B"

NOTCH FOR SPRINKLER

SYSTEM PIPE

TPS CLOSET

Federal Emergency Management Agency

14' WIDE MHU (FURNACE)

DATE:

SCALE:

COMPANY: VERSION:

1/2" = 1'-0"

14F2-16.7

DRAWING NO.

INTERIOR WALLS

Interior Wall Framing Notes

1. All interior walls are 2 x 3 (unless noted) #2 SPF at 16” maximum o.c., except washer wall.

2. Top plates to be 2 x 3 (unless noted) #2 SPF.

3. Bottom plates to be 1 x 3 (unless noted) #2 SPF.

4. Wall interiors shall be faced with ½” Gold Bond XP gypsum board with paint or equivalent installed per ASTM C840 and GA-216.

5. Gypsum board shall run vertically or horizontally along the entire height of wall interiors. See fastening schedule.

6. Wall panel trim (1/2” x 2”) shall be used to cover the gypsum panel joints. Trim fastened to only one of the two gypsum panels into stud, 10" O.C. fastener spacing.

7. Walls shall be sanded as needed to assure a smooth finish (level 3 finish minimum)

P8 x x

B

A C

K E

R

U

P

BCKR

BOTH

2X6

BCKR

DWN

2X6

BCKR

DWN

2X6

H

O R

I Z

O N

T A

L

P A

N E

L

S

I Z

E

P

L I C

A B

L E

59 1/2

H

O R

I Z

O N

T A

L

P A

N E

L

S

I Z

E

P

L I C

A B

L E

2X6 SPRINKLER HEAD BACKER, SPRINKLER

HEAD BACKER LOCATION MAY VARY BASED

ON SPRINKLER DESIGN.

BATH #1

Federal Emergency Management Agency

14' WIDE MHU (FURNACE)

DATE:

SCALE:

COMPANY: VERSION:

1/2" = 1'-0"

14F2-16.8

DRAWING NO.

INTERIOR WALLS

Interior Wall Framing Notes

1. All interior walls are 2 x 3 (unless noted) #2 SPF at 16” maximum o.c., except washer wall.

2. Top plates to be 2 x 3 (unless noted) #2 SPF.

3. Bottom plates to be 1 x 3 (unless noted) #2 SPF.

4. Wall interiors shall be faced with ½” Gold Bond XP gypsum board with paint or equivalent installed per ASTM C840 and GA-216.

5. Gypsum board shall run vertically or horizontally along the entire height of wall interiors. See fastening schedule.

6. Wall panel trim (1/2” x 2”) shall be used to cover the gypsum panel joints. Trim fastened to only one of the two gypsum panels into stud, 10" O.C. fastener spacing.

7. Walls shall be sanded as needed to assure a smooth finish (level 3 finish minimum)

P9

BATH #1

28 1/2

60 1/2

VERTICAL WALL BOARD PANEL BREAKS

H

O R

I Z

O N

T A

L

P A

N E

L

S

I Z

E

P

L I C

A B

L E

H

O R

I Z

O N

T A

L

P A

N E

L

S

I Z

E

P

L I C

A B

L E

Nail on washer box size will vary. Manufacturer to verify size from the washer box vendor that will be used.

14"x14" washer p-trap access panel

(Oatley 34056 or equivalent) for p-trap.

6"x9" louvered access panel (Oatley 34247 or equivalent) for recessed autovent

M

A X

Standpipe cannot be more than 30" above the p-trap weir.

Federal Emergency Management Agency

14' WIDE MHU (FURNACE)

DATE:

SCALE:

COMPANY: VERSION:

1/2" = 1'-0"

14F2-16.9

DRAWING NO.

INTERIOR WALLS

Interior Wall Framing Notes

1. All interior walls are 2 x 3 (unless noted) #2 SPF at 16” maximum o.c., except washer wall.

2. Top plates to be 2 x 3 (unless noted) #2 SPF.

3. Bottom plates to be 1 x 3 (unless noted) #2 SPF.

4. Wall interiors shall be faced with ½” Gold Bond XP gypsum board with paint or equivalent installed per ASTM C840 and GA-216.

5. Gypsum board shall run vertically or horizontally along the entire height of wall interiors. See fastening schedule.

6. Wall panel trim (1/2” x 2”) shall be used to cover the gypsum panel joints. Trim fastened to only one of the two gypsum panels into stud, 10" O.C. fastener spacing.

7. Walls shall be sanded as needed to assure a smooth finish (level 3 finish minimum)

25 1/2

A C

K E

R

U

P

BCKR

UP

2X6

BCKR

UP

2X6

A C

K E

R

U

P

BCKR

UP

2X6

P10

25 1/2

1x

FILLER

2x BLOCK 18" MIN.

M

I N

NOTCH FOR SPRINKLER SYSTEM PIPE

-SEE APPENDIX A-30 DETAIL "B"

NOTCH FOR SPRINKLER

SYSTEM PIPE

BCKR

UP

2X6

BCKR

UP

2X6

25 1/2 4834

W/H - FURNACE

Federal Emergency Management Agency

14' WIDE MHU (FURNACE)

DATE:

SCALE:

COMPANY: VERSION:

3/8" = 1'-0"

14F2-16.10

DRAWING NO.

INTERIOR WALLS

Interior Wall Framing Notes

1. All interior walls are 2 x 3 (unless noted) #2 SPF at 16” maximum o.c., except washer wall.

2. Top plates to be 2 x 3 (unless noted) #2 SPF.

3. Bottom plates to be 1 x 3 (unless noted) #2 SPF.

4. Wall interiors shall be faced with ½” Gold Bond XP gypsum board with paint or equivalent installed per ASTM C840 and GA-216.

5. Gypsum board shall run vertically or horizontally along the entire height of wall interiors. See fastening schedule.

6. Wall panel trim (1/2” x 2”) shall be used to cover the gypsum panel joints. Trim fastened to only one of the two gypsum panels into stud, 10" O.C. fastener spacing.

7. Walls shall be sanded as needed to assure a smooth finish (level 3 finish minimum)

48 48 13 1/2

40 1/2

37 1/2

P11

BACKER

UP

2X6

BACKER

BOTH

2X6

BEDROOM #2

109 1/2

37 1/2

VERTICAL WALL BOARD PANEL BREAKS

O R

I Z

O N

T A

L

P A

N E

L

S

I Z

E

P

L I C

A B

L E

O R

I Z

O N

T A

L

P A

N E

L

S

I Z

E

P

L I C

A B

L E

14 3/4

R.A.G. R.A.G.

14 3/8

NOTCH FOR SPRINKLER

SYSTEM PIPE

(SEE APPENDIX A-30, DETAIL "B")

2x3x2

1x3x2

NOTCH FOR SPRINKLER

SYSTEM PIPE

E

C

B

I N

E T

S

E

A D

C A

B I N

E T

S

BACKER

UP

2X6

BACKER

UP

2X6

BACKER

UP

2X6

BACKER

UP

2X6

BACKER

UP

2X6

BACKER

UP

2X6

BCKR

UP

2X6

BCKR

UP

2X6

2X6 SPRINKLER HEAD BACKER, SPRINKLER

HEAD BACKER LOCATION MAY VARY BASED

ON SPRINKLER DESIGN.

48 48 13 1/2

Federal Emergency Management Agency

14' WIDE MHU (FURNACE)

DATE:

SCALE:

COMPANY: VERSION:

1/4" = 1'-0"

14F2-16.11

DRAWING NO.

INTERIOR WALLS

Interior Wall Framing Notes

1. All interior walls are 2 x 3 (unless noted) #2 SPF at 16” maximum o.c., except washer wall.

2. Top plates to be 2 x 3 (unless noted) #2 SPF.

3. Bottom plates to be 1 x 3 (unless noted) #2 SPF.

4. Wall interiors shall be faced with ½” Gold Bond XP gypsum board with paint or equivalent installed per ASTM C840 and GA-216.

5. Gypsum board shall run vertically or horizontally along the entire height of wall interiors. See fastening schedule.

6. Wall panel trim (1/2” x 2”) shall be used to cover the gypsum panel joints. Trim fastened to only one of the two gypsum panels into stud, 10" O.C. fastener spacing.

7. Walls shall be sanded as needed to assure a smooth finish (level 3 finish minimum)

3 1/2

25 1/2

25 1/2

P12

BED#2 CLO.

3 1/2

25 1/2

VERTICAL WALL BOARD PANEL BREAKS

3 1/2

25 1/2

BED#2 CLO.

Federal Emergency Management Agency

14' WIDE MHU (FURNACE)

DATE:

SCALE:

COMPANY: VERSION:

1/2" = 1'-0"

14F2-16.12

DRAWING NO.

INTERIOR WALLS

Interior Wall Framing Notes

1. All interior walls are 2 x 3 (unless noted) #2 SPF at 16” maximum o.c., except washer wall.

2. Top plates to be 2 x 3 (unless noted) #2 SPF.

3. Bottom plates to be 1 x 3 (unless noted) #2 SPF.

4. Wall interiors shall be faced with ½” Gold Bond XP gypsum board with paint or equivalent installed per ASTM C840 and GA-216.

5. Gypsum board shall run vertically or horizontally along the entire height of wall interiors. See fastening schedule.

6. Wall panel trim (1/2” x 2”) shall be used to cover the gypsum panel joints. Trim fastened to only one of the two gypsum panels into stud, 10" O.C. fastener spacing.

7. Walls shall be sanded as needed to assure a smooth finish (level 3 finish minimum)

P13 x x

B

A C

K E

R

U

P

BED#2 CLO.

2X6 UP

S

H E

L F

VERTICAL WALL BOARD PANEL BREAKS

2X6 UP

S

H E

L F

BED#2 CLO.

Federal Emergency Management Agency

14' WIDE MHU (FURNACE)

DATE:

SCALE:

COMPANY: VERSION:

1/2" = 1'-0"

14F2-16.13

DRAWING NO.

INTERIOR WALLS

Interior Wall Framing Notes

1. All interior walls are 2 x 3 (unless noted) #2 SPF at 16” maximum o.c., except washer wall.

2. Top plates to be 2 x 3 (unless noted) #2 SPF.

3. Bottom plates to be 1 x 3 (unless noted) #2 SPF.

4. Wall interiors shall be faced with ½” Gold Bond XP gypsum board with paint or equivalent installed per ASTM C840 and GA-216.

5. Gypsum board shall run vertically or horizontally along the entire height of wall interiors. See fastening schedule.

6. Wall panel trim (1/2” x 2”) shall be used to cover the gypsum panel joints. Trim fastened to only one of the two gypsum panels into stud, 10" O.C. fastener spacing.

7. Walls shall be sanded as needed to assure a smooth finish (level 3 finish minimum)

E1

BEDROOM #1

48 48 10 x x

B

A C

K E

R

U

P

VERTICAL WALL BOARD PANEL BREAKS

O R

I Z

O N

T A

L

P A

N E

L

S

I Z

E

P

L I C

A B

L E

O R

I Z

O N

T A

L

P A

N E

L

S

I Z

E

P

L I C

A B

L E

3" x 5"…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it.