MUIR WOODS INTERIOR TELECOM UPGRADES Federal contract opportunity
Solicitation number
140P8623Q0044
Issued by
Department of the Interior National Park Service Pacific West Region

View the file

Other files for this federal contract opportunity

Show all 13

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Figure index

List of Figures:
FigureDescriptionSite LocationPg#
1Corning fiber patch panelAdministration bldg, MDF closet7
2Rack elevationsAdministration bldg, MDF closet8
3Building layoutAdministration bldg, MDF closet9
4Corning fiber patch panelOld Inn (aka. Maintenance)12
5Rack elevationsOld Inn (aka. Maintenance)13
6Building layoutOld Inn (aka. Maintenance)14
7Corning fiber patch panelConifer Classroom16
8Rack elevationsConifer Classroom17
9Building layoutConifer Classroom18
10Corning fiber patch panelEducation Lab, lower level21
11Rack elevationsEducation Lab21
12Building layoutEducation Lab22
13Cisco C3560CX-8GConifer Classroom, Education Lab23
14Cisco C9200L-24G-4GAdministration Building, Old Inn24
15MDF, 66 blocks, XconnectAdministration bldg, MDF closet25
16PBX, 66 blocks, XconnectAdministration bldg, MDF closet26
17Cat 6 Patch PanelAdministration bldg, MDF closet, 42 inch rack27
18Patchbox Xconnect shelf, NPSAdministration bldg, MDF closet, 42 inch rack28
19Patchbox Xconnect shelf, Partners, fiber patchAdministration bldg, MDF closet, 42 inch rack29
20Cat 6 Patch PanelOld Inn (aka. Maintenance), 10inch rack30
21Patchbox Xconnect shelf, NPSOld Inn (aka. Maintenance), 10inch rack31
22Cat 6 Patch PanelConifer Classroom, 10inch rack32
23Patchbox Xconnect shelf, NPS, fiber patchConifer Classroom, 10inch rack33
24Cat 6 Patch PanelEducation Lab, 12 inch rack34
25Patchbox Xconnect shelf, NPSEducation Lab, 12 inch rack35
26Government provided equipment (G1-G3)
27Network Topology
Parts list (P1-P32)

BOM-P

Item#QTYLocationProduct Description
P11Admin110-Style Wiring Block, wall mount
P21Admin, Old Inn42U Rack Enclosure 36" Depth w Doors & Sides 3000lb Capacity
P31AdminPDU Metered 208V / 240V 30A 6 C19 24; C13 L6-30P Vertical rear mounted
P42Admin,Rack Enclosure Fixed Shelf, 19 inch
P51ConniferBack-UPS, Battery Backup & Surge Protector w/ USB, 8-Outlets, rack mount, 19 inch
P63ConiferCat 6 Patch Panel, Rack Mount, 24-Port, 1 RU, 19 inch
P70Admin, Old InnPATCHBOX Frame holds up to 24 PATCHBOX Cassettes, includes 6 Patchcatch cable loops.
P80Admin, Old InnPatchbox Cat6a Cable Cassette, Flat Cat.6a U/FTP, ISO/IEC 11801 Channel Class Ea, ANSI/EIA/TIA-568 Cat 6A Channel, 500MHz, AWG36, 100% stranded copper, PVC jacket, PoE (802.3af), RoHS compliant, Green
P90Admin, Old InnPatchbox Cat6a Cable Cassette, Flat Cat.6a U/FTP, ISO/IEC 11801 Channel Class Ea, ANSI/EIA/TIA-568 Cat 6A Channel, 500MHz, AWG36, 100% stranded copper, PVC jacket, PoE (802.3af), RoHS compliant, Blue
P100Admin, Old InnPATCHBOX Identification Label 96pcs.
P110Admin, Old Inn, ConiferOM4 RBS 50μ/125μ, LSZH, Erika Violet, Multi-Mode, RoHS compliant, LC Duplex – LC Duplex / LC Duplex – SC Duplex, 0.8m covers 8RU
P1222Admin, Old Inn, ConiferSurface Mount Housing - modular insert housing, 2 port, white
P1370Admin, Old Inn, ConiferSurface Raceway channel is a one-piece latching channel with integrated cover and is designed to route, protect, and conceal data, voice, and video cabling, white.
P144Admin, Old Inn, Coniferright angle fitting is a Surface Raceway fitting designed to transition your raceway around a corner while maintaining a 1 inch bend radius. It meets TIA/EIA Standards, is UL5A Listed, and is UL Compliant. White.
P159Admin, Old Inn, ConiferThe inside corner fitting is used to efficiently run cables along an inside corner while maintaining a 1 inch bend radius. It meets TIA/EIA, White.
P1624Admin, Old Inn, ConiferThe low voltage tee fitting extends cable runs in a tee configuration and is used with LD5 raceway. It is White.
P172Admin, Old Inn, ConiferThe outside corner fitting is a Surface Raceway fitting designed to transition your raceway around an outside corner while maintaining a 1 inch bend radius. It meets TIA/EIA Standards and is UL Compliant. White.
P1816Admin, Old Inn, ConiferThe end cap fitting allows for closing off one end of the Surface Raceway when you no longer need to run cables. It meets TIA/EIA Standards, is UL5A Listed, and is UL Compliant. White.
P1960Admin, Old Inn, ConiferThe coupler fitting is used to efficiently manage cable placement. TIA/EIA Standards, is UL5A Listed, and is UL Compliant. White.
P2044Admin, Old Inn, ConiferMounting strap. White.
P212Admin, Old Inn, ConiferCAT6 - 1000ft Green Bulk Ethernet Patch Cable
P220Admin, Old InnCat6 PoE Patch Panel 24-Port 110/Krone 568A/B RJ45 1URM TAA, 19 inch
P2332Admin, Old Inn, ConiferCat6, 110 Punch Down Jack - modular insert Green
P2412Admin, Old Inn, ConiferCat6, 110 Punch Down Jack - modular insert Blue
P269Admin, Old InnSleeve Kit: 2 in Lg, 2 1/2 in Wd, 2 in Ht
P27Admin, Old InnFirestop Sealant, Red, Fire Barrier Sealant
P282Admin, Old InnAPC Smart-UPS C 1500VA SmartConnect Port Sinewave 2U Rackmount, LCD, 120V, 19 inch
P292Old Inn, ConiferPDU Basic 120V 15A 5-15R 13 Outlet 5-15P Horizontal 1URM, 19 inch
P302Conifer10U Wall Mount Server Rack Enclosure Cabinet Hinged Wallmount
P311ConiferRack Enclosure Cabinet Cantilever Fixed Shelf 40lb Capacity 1URM

BOM-G

Item#QTYManufacturerPart NumberLocationProduct DescriptionLink to productSupplierPriceUnit
G12CiscoC9200L-24P-4G-E++Admin, Old Inn24 port POE switchC9200L-24P-4G-E++$2,625.99ea
G21CiscoWS-C3560CX-8PCS++Conifer Classroom8 port POE SwitchWS-C3560CX-8PCS++$1,426.99ea
G35ProlineGLC-SX-MM-GT3 at Admin, 1 at Old Inn, 1 at ConiferProline Cisco GLC-LH-SMD Compatible SFP TAA Compliant Transceiver - SFP (mini-GBIC) transceiver module - GigEGLC-SX-MM-PROCDW$82.99ea
G44PatchboxAdmin, Old InnPATCHBOX Frame holds up to 24 PATCHBOX Cassettes, includes 6 Patchcatch cable loops.Patchbox framePatchbox$117.00ea$468.00
G550PatchboxAdmin, Old InnPatchbox Cat6a Cable Cassette, Flat Cat.6a U/FTP, ISO/IEC 11801 Channel Class Ea, ANSI/EIA/TIA-568 Cat 6A Channel, 500MHz, AWG36, 100% stranded copper, PVC jacket, PoE (802.3af), RoHS compliant, GreenPatchbox cassettes Cat6 copper, GreenPatchbox$22.00ea$1,100.00
G68PatchboxAdmin, Old InnPatchbox Cat6a Cable Cassette, Flat Cat.6a U/FTP, ISO/IEC 11801 Channel Class Ea, ANSI/EIA/TIA-568 Cat 6A Channel, 500MHz, AWG36, 100% stranded copper, PVC jacket, PoE (802.3af), RoHS compliant, BluePatchbox cassettes Cat6 copper, BluePatchbox$22.00$176.00
G72PatchboxAdmin, Old InnPATCHBOX Identification Label 96pcs.Patchbox labelsPatchbox$18.00ea$36.00
G810PatchboxAdmin, Old Inn, ConiferOM4 RBS 50μ/125μ, LSZH, Erika Violet, Multi-Mode, RoHS compliant, LC Duplex – LC Duplex / LC Duplex – SC Duplex, 0.8m covers 8RUPatchbox cassettes OM4 fiberPatchbox$25.00ea$250.00
$4,135.97

https://www.cdw.com/product/proline-cisco-glc-sx-mm-compatible-sfp-taa-compliant-transceiver-sfp-min/3269878?pfm=srhhttps://www.cdw.com/product/cisco-catalyst-9200l-network-essentials-switch-24-ports-rack-mounta/5804326?pfm=srhhttps://www.cdw.com/product/cisco-catalyst-3560cx-8pc-s-switch-8-ports-managed-taa-compliant/5901203?pfm=srhhttps://shop.patchbox.com/en-us/products/patchbox-365-frame?variant=43636347076850https://shop.patchbox.com/en-us/products/patchbox-365-cat-6a-cassette?variant=43636378894578https://shop.patchbox.com/en-us/products/patchbox-identification-label-96pcs?variant=43636145160434https://shop.patchbox.com/en-us/products/patchbox-365-fiber-optic-cassette?variant=43636583432434https://shop.patchbox.com/en-us/products/patchbox-365-cat-6a-cassette?variant=43636378829042 Cable Cut Sheet

Administration Building
SourceDestination
To LocationPatchboxTo Location
Surface Mount Housing1A
Surface Mount Housing1B
Surface Mount Housing2A
Surface Mount Housing2B
Surface Mount Housing3A
Surface Mount Housing3B
Surface Mount Housing4A
Surface Mount Housing4B
Surface Mount Housing5A
Surface Mount Housing5B
Surface Mount Housing6A
Surface Mount Housing6B
Surface Mount Housing7A
Surface Mount Housing7B
Surface Mount Housing8A
Surface Mount Housing8B
Surface Mount Housing9A
Surface Mount Housing9B
Surface Mount Housing10A
Surface Mount Housing10B
Surface Mount Housing11A
Surface Mount Housing11B
Surface Mount Housing12A
Surface Mount Housing12B
Administration Building
SourceDestination
To LocationPatchboxTo Location
NPS Cisco 9200L SwitchGig1/0/1NPS Green Patchbox shelf 1Patch Panel position 11A
NPS Cisco 9200L SwitchGig1/0/2Patch Panel position 32A
NPS Cisco 9200L SwitchGig1/0/3Patch Panel position 53A
NPS Cisco 9200L SwitchGig1/0/4Patch Panel position 74A
NPS Cisco 9200L SwitchGig1/0/5Patch Panel position 95A
NPS Cisco 9200L SwitchGig1/0/6Patch Panel position 116A
NPS Cisco 9200L SwitchGig1/0/7Patch Panel position 137A
NPS Cisco 9200L SwitchGig1/0/8Patch Panel position 158A
NPS Cisco 9200L SwitchGig1/0/9Patch Panel position 179A
NPS Cisco 9200L SwitchGig1/0/10Patch Panel position 1910A
NPS Cisco 9200L SwitchGig1/0/11Patch Panel position 2111A
NPS Cisco 9200L SwitchGig1/0/12Patch Panel position 2312A
Administration Building
SourceDestination
To LocationPatchboxTo Location
NPC SwitchGig0/1Patch Panel position 21B
NPC SwitchGig0/2Patch Panel position 42B
NPS Cisco 9200L SwitchGig1/1/1Corning lower Port 1MAINTENANCE
NPS Cisco 9200L SwitchGig1/1/2Corning upper Port 1CONIFER
NPS Cisco 9200L SwitchGig1/1/4Future WANTBD
Old Inn
SourceDestination
To LocationPatchboxTo Location
Surface Mount Housing1A
Surface Mount Housing1B
Surface Mount Housing2A
Surface Mount Housing2B
Surface Mount Housing3A
Surface Mount Housing3B
Surface Mount Housing4A
Surface Mount Housing4B
Surface Mount Housing5A
Surface Mount Housing5B
Surface Mount Housing6A
Surface Mount Housing6B
Surface Mount Housing7A
Surface Mount Housing7B
Surface Mount Housing8A
Surface Mount Housing8B
future
future
future
future
future
future
future
future
Old Inn
SourceDestination
To LocationPatchboxTo Location
NPS Cisco 9200L SwitchGig1/0/1NPS Green Patchbox shelf 1Patch Panel position 11A
NPS Cisco 9200L SwitchGig1/0/2Patch Panel position 32A
NPS Cisco 9200L SwitchGig1/0/3Patch Panel position 53A
NPS Cisco 9200L SwitchGig1/0/4Patch Panel position 74A
NPS Cisco 9200L SwitchGig1/0/5Patch Panel position 95A
NPS Cisco 9200L SwitchGig1/0/6Patch Panel position 116A
NPS Cisco 9200L SwitchGig1/0/7Patch Panel position 137A
NPS Cisco 9200L SwitchGig1/0/8Patch Panel position 158A
future
future
future
future
NPS Cisco 9200L SwitchGig1/0/4Pink Patchbox shelf 2Patch Panel position 24ADMIN BUILDING PORT 1
Conifer Classroom
SourceDestination
To LocationPatchboxTo Location
Surface Mount Housing1A
Surface Mount Housing1B
Surface Mount Housing2A
Surface Mount Housing2B
future
future
future
future
future
future
future
future
future
future
future
future
future
future
future
future
future
future
future
future
Conifer Classroom
SourceDestination
To LocationPatchboxTo Location
NPS Cisco C3560CX SwitchGig1/0/1Patchbox shelf 1Patch Panel position 11A
NPS Cisco C3560CX SwitchGig1/0/2Patchbox shelf 1Patch Panel position 32A
futurefuture
futurefuture
futurefuture
futurefuture
NPS Cisco C3560CX SwitchGig1/0/10Pink Patchbox shelf 1Patch Panel position 10ADMIN BUILDING PORT 1
Education Lab
SourceDestination
To LocationPatchboxTo Location
Surface Mount Housing1A
Surface Mount Housing1B
Surface Mount Housing2A
Surface Mount Housing2B
Surface Mount Housing3A
Surface Mount Housing3B
Surface Mount Housing48
Surface Mount Housing4B
future
future
future
future
future
future
future
future
future
future
future
future
future
future
future
future
Education Lab
SourceDestination
To LocationPatchboxTo Location
NPS Cisco C3560CX SwitchGig1/0/1Patch Panel position 11A
NPS Cisco C3560CX SwitchGig1/0/2Patch Panel position 32A
NPS Cisco C3560CX SwitchGig1/0/3Patch Panel position 53A
NPS Cisco C3560CX SwitchGig1/0/4Patch Panel position 74A
futurefuture
futurefuture
futurefuture
futurefuture
futurefuture
futurefuture

Bill of Materials

zProject Name:Name:
zAddress:
5/1/23 16:19Phone Number:
Created using Corning BOM Toolemail:
Version 2.50Application:
Description/LocationPart NumberSpec SheetProviderQty
Buffer Tube Fanout Kit, Outdoor, 12 Fiber, 25" LegsFAN-OD25-125

wgeary: wgeary:

2 for bldg 64 side to chapel 2 for chapel side to bldg 64 2 for chapel side to qtr master 2 for qtr master to chapel

SPH-01P Panel Housing, holds a single panel SPH-01P 5 wgeary: wgeary:

1 for bldg 64 side to chapel 2 for chapel side to bldg 64 1 for qtr master to chapel CCH-CP12-A8 Patch Panel Insert CCH-CP12-A8 5 wgeary: wgeary:

1 for bldg 64 side to chapel 2 for chapel side to bldg 64 1 for qtr master to chapel

RFC-LC6 LC ConnectorRFC-LC61
2 Meter LC/LC Multimode Cable (6 feet)039696002M10

&"arial unicode ms,Regular"© 2018 Corning Incorporated. All Rights Reserved.

&"arial unicode ms,Regular"© 2018 Corning Incorporated. All Rights Reserved.

Bill-of-Materials Tool

UniCams

Date:7/31/2020
ES Project # Project #
Hardware / LocationPart NumberSpec SheetBuilding 1Building 2TOTAL

QTY

# fibers
Cable
ALTOS® Lite™ Loose Tube, Single-Jacket, Single-Armored Cable, 12 F, 50 µm multimode (OM3)012TUC-T4180D20Spec SheetTBD
Hardware
Closet Connector Housing (CCH), 1 rack unit, accepts up to 2 CCH panels, cassettes or modules; comes with blank panels and hardware to strain-relieve cables internally or externallyCCH-01USpec Sheet112
CCH Panel
Closet Connector Housing (CCH) Panel, 12 F, LC Duplex, 50 µm multimode (OM3/OM4)CCH-CP12-E4Spec Sheet112
UniCam
UniCam® High-Performance Connectors, LC, 50 µm multimode (OM3/OM4/OM4 extended 10G distance)95-050-99-XSpec Sheet121224
Buffer Tube Fanout Kit
Buffer Tube Fanout Kit, Indoor, 12 Fiber, 25" LegsFAN-BT25-12Spec Sheet112
Jumpers
Fiber Optic Patch Cord, 2 Fibers, LC Duplex to LC Duplex, Zipcord Tight-Buffered Cable, Riser, with 2.0 mm legs, 50 µm multimode (OM4), 3 meters050502Q5120003MSpec Sheet6612
Notes:
- Cable routes and estimated distances are speculative and need to be verified before ordering
Disclaimer:
The attached Bills of Materials (BOM) is supplied with the understanding that the products and product quantities are derived from, customer supplied information. As a result the customer is responsible for the accuracy and content of all products and product quantities provided in the Bill of Materials. Customer should verify/check all information provided to ensure it meets and reflects the project requirements. Corning Cable Systems assumes no responsibility for any inaccurate or incorrect information provided from this BOM. Corning Cable Systems will be responsible for any pricing supplied if applicable.

&"arial,Regular"&10© 2021 Corning Incorporated. All Rights Reserved.&8

&"arial,Regular"&10© 2021 Corning Incorporated. All Rights Reserved.&8

&"arial unicode ms,Regular"© 2017 Corning Incorporated. All Rights Reserved.

Proposal #11844 Engelhard Catalysts and Chemical Division, Attapulgus, Georgia Fiber Optic Hardware Requirements Phase 2

BOM

http://csmedia.corning.com/opcomm/Resource_Documents/product_family_specifications_rl/ALTOS_Lite_Gel_Free_Single_Jacket_Single_Armor_Cables_6_432_Fibers_NAFTA_AEN.pdfhttp://csmedia.corning.com/opcomm/Resource_Documents/product_family_specifications_rl/Closet_Connector_Housings_CCH_NAFTA_AEN.pdfhttp://csmedia.corning.com/opcomm/Resource_Documents/product_family_specifications_rl/Cable_Assemblies_Two_Fiber_NAFTA_NAFTA_AEN.pdfhttp://csmedia.corning.com/opcomm/Resource_Documents/product_family_specifications_rl/Closet_Connector_Housing_Panels_CCH_CP_NAFTA_AEN.pdf?context=;CCS_Global_Web_Catalog;fiber_optic_hardware_web;rack_mountable_hardware_web;CCH_hardware_web;CCH_panels_web;CCH_panels_web;&rooot=productshttp://csmedia.corning.com/opcomm/Resource_Documents/product_family_specifications_rl/UniCam_High_Performance_Connectors_Multimode_and_Single_Mode_NAFTA_AEN.pdfhttp://csmedia.corning.com/opcomm/Resource_Documents/product_family_specifications_rl/EVO-163-EN.pdf CCH Pigtailed Cassette

Date:7/31/2020
ES Project # Project #
Hardware / LocationPart NumberSpec SheetBuilding 1Building 2TOTAL

QTY

# fibers
Cable
ALTOS® Lite™ Loose Tube, Single-Jacket, Single-Armored Cable, 12 F, 50 µm multimode (OM3)012TUC-T4180D20Spec SheetTBD
Hardware
Closet Connector Housing (CCH), 1 rack unit, accepts up to 2 CCH panels, cassettes or modules; comes with blank panels and hardware to strain-relieve cables internally or externallyCCH-01USpec Sheet112
CCH Pigtailed Cassette
Closet Connector Housing (CCH) Pigtail Cassette, loaded with CCH panel and factory-terminated pigtails, 12 F, LC Duplex, OM3, single fiber splicingCCH-CS12-E4-P00TESpec Sheet112
Jumpers
Fiber Optic Patch Cord, 2 Fibers, LC Duplex to LC Duplex, Zipcord Tight-Buffered Cable, Riser, with 2.0 mm legs, 50 µm multimode (OM4), 3 meters050502Q5120003MSpec Sheet6612
Notes:
- Cable routes and estimated distances are speculative and need to be verified before ordering
Disclaimer:
The attached Bills of Materials (BOM) is supplied with the understanding that the products and product quantities are derived from, customer supplied information. As a result the customer is responsible for the accuracy and content of all products and product quantities provided in the Bill of Materials. Customer should verify/check all information provided to ensure it meets and reflects the project requirements. Corning Cable Systems assumes no responsibility for any inaccurate or incorrect information provided from this BOM. Corning Cable Systems will be responsible for any pricing supplied if applicable.

&"arial,Regular"&10© 2021 Corning Incorporated. All Rights Reserved.&8

&"arial,Regular"&10© 2021 Corning Incorporated. All Rights Reserved.&8

&"arial unicode ms,Regular"© 2017 Corning Incorporated. All Rights Reserved.

Proposal #11844 Engelhard Catalysts and Chemical Division, Attapulgus, Georgia Fiber Optic Hardware Requirements Phase 2

BOM

http://csmedia.corning.com/opcomm/Resource_Documents/product_family_specifications_rl/ALTOS_Lite_Gel_Free_Single_Jacket_Single_Armor_Cables_6_432_Fibers_NAFTA_AEN.pdfhttp://csmedia.corning.com/opcomm/Resource_Documents/product_family_specifications_rl/Closet_Connector_Housings_CCH_NAFTA_AEN.pdfhttp://csmedia.corning.com/opcomm/Resource_Documents/product_family_specifications_rl/Closet_Connector_Housings_CCH_NAFTA_AEN.pdfhttp://csmedia.corning.com/opcomm/Resource_Documents/product_family_specifications_rl/Cable_Assemblies_Two_Fiber_NAFTA_NAFTA_AEN.pdf BOM-P Option 1

Item#QTYLocationProduct Description
P10110-Style Wiring Block
P2042U Rack Enclosure 36" Depth w Doors & Sides 3000lb Capacity
P30PDU Metered 208V / 240V 30A 6 C19 24; C13 L6-30P Vertical 0URM
P40Rack Enclosure Fixed Shelf
P50Back-UPS, Battery Backup & Surge Protector w/ USB, 8-Outlets
P61Ed LabCat 6 Patch Panel, Rack Mount, 24-Port, 1 RU, 19 inch
P70Ed LabPATCHBOX Frame holds up to 24 PATCHBOX Cassettes, includes 6 Patchcatch cable loops.
P80Ed LabPatchbox Cat6a Cable Cassette, Flat Cat.6a U/FTP, ISO/IEC 11801 Channel Class Ea, ANSI/EIA/TIA-568 Cat 6A Channel, 500MHz, AWG36, 100% stranded copper, PVC jacket, PoE (802.3af), RoHS compliant, Green
P90Patchbox Cat6a Cable Cassette, Flat Cat.6a U/FTP, ISO/IEC 11801 Channel Class Ea, ANSI/EIA/TIA-568 Cat 6A Channel, 500MHz, AWG36, 100% stranded copper, PVC jacket, PoE (802.3af), RoHS compliant, Blue
P100Ed LabPATCHBOX Identification Label 96pcs.
P110OM4 RBS 50μ/125μ, LSZH, Erika Violet, Multi-Mode, RoHS compliant, LC Duplex – LC Duplex / LC Duplex – SC Duplex, 0.8m covers 8RU
P125Ed LabLeviton QuickPort Surface Mount Housing - modular insert housing
P1310Ed LabSurface Mount Housing - modular insert housing, 2 port, white
P143Ed LabSurface Raceway channel is a one-piece latching channel with integrated cover and is designed to route, protect, and conceal data, voice, and video cabling, white.
P154Ed Labright angle fitting is a Surface Raceway fitting designed to transition your raceway around a corner while maintaining a 1 inch bend radius. It meets TIA/EIA Standards, is UL5A Listed, and is UL Compliant. White.
P166Ed LabThe inside corner fitting is used to efficiently run cables along an inside corner while maintaining a 1 inch bend radius. It meets TIA/EIA, White.
P172Ed LabThe low voltage tee fitting extends cable runs in a tee configuration and is used with LD5 raceway. It is White.
P184Ed LabThe outside corner fitting is a Surface Raceway fitting designed to transition your raceway around an outside corner while maintaining a 1 inch bend radius. It meets TIA/EIA Standards and is UL Compliant. White.
P196Ed LabThe end cap fitting allows for closing off one end of the Surface Raceway when you no longer need to run cables. It meets TIA/EIA Standards, is UL5A Listed, and is UL Compliant. White.
P2012Ed LabThe coupler fitting is used to efficiently manage cable placement. TIA/EIA Standards, is UL5A Listed, and is UL Compliant. White.
P211Ed LabMounting strap. White.
P220CAT6 - 1000ft Green Bulk Ethernet Patch Cable
P239Ed LabCat6 PoE Patch Panel 24-Port 110/Krone 568A/B RJ45 1URM TAA, 19 inch
P240Ed LabCat6, 110 Punch Down Jack - modular insert Green
P264Ed LabCat6, 110 Punch Down Jack - modular insert Blue
P27Admin, Old InnFirestop Sealant, Red, Fire Barrier Sealant
P281Ed LabAPC Smart-UPS C 1500VA SmartConnect Port Sinewave 2U Rackmount, LCD, 120V
P291Ed LabPDU Basic 120V 15A 5-15R 13 Outlet 5-15P Horizontal 1URM, 19 inch
P300Ed Lab10U Wall Mount Server Rack Enclosure Cabinet Hinged Wallmount
P311Ed LabRack Enclosure Cabinet Cantilever Fixed Shelf 40lb Capacity 1URM
P321Admin, Old Inn, ConiferFiber Patch Cable, LC/LC 50/125 OM3 Multimode, 10 M
P331Ed Lab12U Rack Enclosure Server Cabinet Doors; Sides 300lb Capacity - rack - 12U
P341Admin, Old Inn, ConiferSC-SC Duplex MM Patch Cord OM4 50um, 10m

BOM-G Option 1

Item#QTYManufacturerPart NumberLocationProduct Description
G11CiscoWS-C3560CX-8PCS++Ed Lab8 port POE Switch
G22ProlineGLC-SX-MM-GT3 at Admin, 1 at Old Inn, 1 at ConiferProline Cisco GLC-LH-SMD Compatible SFP TAA Compliant Transceiver - SFP (mini-GBIC) transceiver module - GigE
G41PatchboxAdmin, Old InnPATCHBOX Frame holds up to 24 PATCHBOX Cassettes, includes 6 Patchcatch cable loops.
G510PatchboxAdmin, Old InnPatchbox Cat6a Cable Cassette, Flat Cat.6a U/FTP, ISO/IEC 11801 Channel Class Ea, ANSI/EIA/TIA-568 Cat 6A Channel, 500MHz, AWG36, 100% stranded copper, PVC jacket, PoE (802.3af), RoHS compliant, Green
G60PatchboxAdmin, Old InnPatchbox Cat6a Cable Cassette, Flat Cat.6a U/FTP, ISO/IEC 11801 Channel Class Ea, ANSI/EIA/TIA-568 Cat 6A Channel, 500MHz, AWG36, 100% stranded copper, PVC jacket, PoE (802.3af), RoHS compliant, Blue
G70PatchboxAdmin, Old InnPATCHBOX Identification Label 96pcs.
G80PatchboxAdmin, Old Inn, ConiferOM4 RBS 50μ/125μ, LSZH, Erika Violet, Multi-Mode, RoHS compliant, LC Duplex – LC Duplex / LC Duplex – SC Duplex, 0.8m covers 8RU