SECTION 02 41 00 Demolition.docx

DOCX document 21 KB Posted

Attached to
Y1DA--NRM: 640-19-100 Replace and Modernize Elevators at Building 100 Federal contract opportunity
Solicitation number
36C26121R0044
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 21

About this file

This document contains specifications for selective demolition work related to the modernization of elevators in Building 100 at the VA Palo Alto Health Care System. The work includes completely demolishing and removing existing equipment and electrical systems, as well as cutting roof coverings and structural members to allow for removal of old equipment and installation of new systems. Upon completion, the site must be cleaned and left in a satisfactory condition. The related federal contract opportunity is solicitation number 36C26121R0044 for the modernization of elevators in Buildings 100 and 101 at the VA Palo Alto Healthcare System, to be awarded by the Department of Veterans Affairs Veterans Health Administration VISN 21. Selective demolition specifications require protecting facilities and occupants from hazards during removal work, preventing dust and debris spread, and ensuring structural support.

View the file

Other files for this federal contract opportunity

Other files attached to Y1DA--NRM: 640-19-100 Replace and Modernize Elevators at Building 100, newest first.
File Type Posted
CONTRACTOR CERTIFICATION REGARDING SAFETY AND ENVIRONMENTAL.docx DOCX document
S02 - RFI FORM.docx DOCX document
138-18-28 Lock out Tag out.docx DOCX document
P07 Wage Determination CA20210018 03.05.21.pdf PDF
Addendum1-B100 B101_Elevator_Interior_Dwg.pdf PDF
PAD B100 B101 Elevator Interior Finsh Spec.docx DOCX document
SECTION 01 74 19 Construction Waste Management.docx DOCX document
SECTION 01 57 19 Temporary Environmental Controls.docx DOCX document
SECTION 01 35 36 Safety Requirements.docx DOCX document
SECTION 01 32 16 15 Project Schedule.docx DOCX document
138-17-19 WORKING ON ELECTRICAL DISTRIBUTION SYSTEMS.doc DOC document
S02 Price Breakdown by Division.docx DOCX document
014500 Quality Control.docx DOCX document
SECTION 01 33 32 Shop Drawings Product Data and Samples.docx DOCX document
SECTION 01 00 00 General Requirements Elevator Updated 03.01.21.rtf RTF text file
36C26121R0044.docx DOCX document
Show all 16

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Replace and Modernize Elevators at Building 100 640-19-100 Palo Alto, Building 100, VA Palo Alto Health Care System Final Bid Document

02 41 00

SELECTIVE DEMOLITION

PART 1 GENERAL

1.1 DESCRIPTION:

This section specifies demolition and removal of portions of buildings, utilities, other structures and debris.

1.2 RELATED WORK:

A. Not Used.

1.3 PROTECTION:

A.Perform demolition in such manner as to eliminate hazards to persons and property; to minimize interference with use of adjacent areas, utilities and structures or interruption of use of such utilities; and to provide free passage to and from such adjacent areas of structures. Comply with requirements of GENERAL CONDITIONS Article, ACCIDENT PREVENTION.
B.Provide safeguards, including warning signs, barricades, temporary fences, warning lights, and other similar items that are required for protection of all personnel during demolition and removal operations. Comply with requirements of Section 01 00 00, GENERAL REQUIREMENTS, Article PROTECTION OF EXISTING VEGETATION, STRUCTURES, EQUIPMENT, UTILITIES AND IMPROVEMENTS.
E.Prevent spread of flying particles and dust. Sprinkle rubbish and debris with water to keep dust to a minimum. Do not use water if it results in hazardous or objectionable condition such as, but not limited to; ice, flooding, or pollution. Vacuum and dust the work area daily.
F.NOT USED:
G.Before beginning any demolition work, the Contractor shall survey the site and examine the drawings and specifications to determine the extent of the work. The contractor shall take necessary precautions to avoid damages to existing items to remain in place, to be reused, or to remain the property of the Medical Center; any damaged items shall be repaired or replaced as approved by the Contracting Officers Representative. The Contractor shall coordinate the work of this section with all other work and shall construct and maintain shoring, bracing, and supports as required. The Contractor shall ensure that structural elements are not overloaded and shall be responsible for increasing structural supports or adding new supports as may be required as a result of any cutting, removal, or demolition work performed under this contract. Do not overload structural elements. Provide new supports and reinforcement for existing construction weakened by demolition or removal works. Repairs, reinforcement, or structural replacement must have Contracting Officers Representative’s approval.
H.The work shall comply with the requirements of Section 01 57 19, TEMPORARY ENVIRONMENTAL CONTROLS.
I.The work shall comply with the requirements of Section 01 00 00, GENERAL REQUIREMENTS, Article 1.7 INFECTION PREVENTION MEASURES.

1.4 UTILITY SERVICES:

A.NOT USED.
B.NOT USED

PART 2 - PRODUCTS (NOT USED)

PART 3 – EXECUTION

3.1 DEMOLITION:

A. Completely demolish and remove equipment, electrical and associated materials.

B. Cut roof coverings, sheet metal and structural members as needed to provide an opening large enough to remove existing equipment and install new equipment.

C. Store removed roof section out of the way of lifting operations to ne reinstalled at the completion of the lifting operation(s).

3.2 CLEANUP:

On completion of work of each phase and after removal of all debris, leave site in clean condition satisfactory to Contracting Officers Representative. Cleanup shall include off the Medical Center disposal of all items and materials not required to remain property of the Government as well as all debris and rubbish resulting from demolition operations.