This file is the District Traffic Equipment Standards document prepared by OversightDistrict.org in Orlando, Florida, establishing technical specifications for traffic signal infrastructure and related equipment. The document provides comprehensive equipment standards organized by functional category, including traffic cabinets, controllers, power supplies, detection systems, pedestrian signals, and intelligent transportation system (ITS) equipment. Specific manufacturer models are designated with "or approved equivalent" language throughout, allowing for alternative products meeting equivalent performance standards. The standards cover signal housing, Opticom preemption systems, uninterrupted power supplies, closed-circuit television cameras, dynamic message signs, network equipment including managed field ethernet switches and fiber optic communications infrastructure, and pull box and conduit standards conforming to FDOT Index 635 specifications. The document addresses installation requirements including mule tape and tracer wire placement, grounding rod installation to achieve maximum 25-ohm resistance, and comprehensive as-built documentation requirements in CAD, Shapefile, and PDF formats with geolocation of all conduits, pull boxes, splices, connections, terminations, and ground rod locations.

The standards specify material requirements for infrastructure components, including 2-inch HDPE conduit color-coded by system type (grey for traffic signals, orange for fiber optic), pull box and vault dimensions ranging from 13" x 24" x 12" to 36" round x 24", fiber optic cable placement intervals with specified slack requirements, and illuminated street name sign specifications with detailed dimension and material requirements. All equipment selections include brand-specific models such as Temple, Q-Free, Siemens, EDI, GE, McCain, Daktronics, and Corning products, with the "or approved equivalent" clause providing flexibility in procurement while maintaining standardized performance levels across the district's traffic infrastructure network.

View the file

Other files

File Type Posted
SA-06 - Traffic Signal Improvements Design FY26_GeotechReport.pdf PDF
Compliance with FL Statutes Affidavit (1).pdf PDF
EXHIBIT B- Schedule of Unit Rates.pdf PDF
SA-07 - Traffic Signal Improvements Design FY26_MastArmCalcs.pdf PDF
Div 2 and 3 CFTOD Specifications - Signal Design. r1.pdf PDF
SA-01 - RCES Underground Construction Rules (REV 7).pdf PDF
Exhibit C - Project - Client Reference Form v.12.25 (1).pdf PDF
EXHIBIT F-Warranty Offered Form (1).pdf PDF
Affidavit of Eligibility Form - Opportunity Zone Program v.12.25.pdf PDF
CFTOD Erosion Control Notes.pdf PDF
Affidavit of Eligibility Form - Buy Local or Veteran Small Business Program 12.25.pdf PDF
SA-04 - 2026 CFTOD Storm Preparation Procedures for Contractors Revised 2026.04 (1).rtf RTF text file
EXHIBIT A- Scope of Services.pdf PDF
IFB_Traffic Signal Improvements Design FY26 Victory Way Buena Vista Drive.pdf PDF
RCES Lock Out Tag Out.pdf PDF
EXHIBIT E-Emergency Response Form (1).pdf PDF
C007124 - Division 1 - Project Specifications r1.docx DOCX document
EXHIBIT D-Subcontractor List v.12.25 (3).pdf PDF
SA-05 - MA 1-6 Utility Locates - For Reference Only.pdf PDF
ATTACHMENTS 1-6.pdf PDF
Bidder Requirements Checklist v.4SM.pdf PDF
RCES Confined Space.pdf PDF
SA-02 - CFTOD Insurance Requirements REV 02.27.25.pdf PDF
Show all 23

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

OversightDistrict.org

P.O. Box 690519

Orlando, FL 32869-0519

(407) 828-2250

Traffic Signal Equipment Standards

Traffic Cabinet

Temple TS2 type 1, Size 6, 67” Double Door with Generator Compartment, photocell, power management (District alarm, preemption, District key, Slip resistant Laptop pad and relay configuration) ELS1008FLG2 or approved equivalent

Outside: Midnight Neutral

Inside: White

Traffic Controller

Q-Free – XN-2 Controller with Maxtime and Kinetics License or approved equivalent

Power Supply

Siemens CPS105 or approved equivalent

Southern Manufacturing ITS Commander or approved equivalent

Malfunction Management Unit

EDI - 16LEIP or approved equivalent

Loadswitch, Flasher & BIU

EDI or approved equivalent

Video/Radar Detection – ITS Plus or approved equivalent

ITS Plus

Processor – ITSP-V600-0

SDLC – LUXCOM ITSP-SDLC-L

BIU – ITSP-SDLC-GF Advanced Vivds Solution

Monitor – Minimum of 10” Color Flat Screen Display

Surge – DTK-WM4NETS

Camera – Thunder Series ITSP-PMPOE or Wide Angle Depending on Location

Pedestrian Detection

Polara Bulldog push button or approved equivalent

Traffic Signal Indications

Vehicular Signals – GE 12” LED Signals

Transit Signal – GE 12” White LED Signals

Pedestrian Signal – GE 16” Pedestrian Countdown pwheatley Text Box

SA-03

(407) 828-2250

Illuminated Street Name Signs

Southern Manufacturing Top Mount, LED Light Engine or approved equivalent

Panel: Width 9’-0”, Height 24”, Legend White, Polycarbonate White, Film: Color Hunter Green (GMI CV 300-18)

Body: Black

Border: Width 1” with radius, Color white

Text: Font FHWA Series E 8”UC, Word Spacing 8”, Upper and Lowercase letters

Traffic Signal Housing

Vehicular Signal – McCain 12” Die Cast With Yellow Reflectorized Backplate

Opticom – Infrared and GPS

GTT – 711 Opticom Infrared Detector

GTT – 760 Power Supply Rack or approved equivalent

GTT – 764 Multi-Mode Phase Selector or approved equivalent

GTT – Central Management System License

GTT – 768 Aux Interface Panel or approved equivalent

GTT – 3101 Cabinet Mount GPS Radio Unit or approved equivalent

GTT – 1070-1 Opticom Cable

GTT – 721 Single or 722 Dual Infrared Detector

Uninterrupted Power Supply

Temple SE48-2216 Aluminum enclosure with generator compartment, automatic transfer, slide out battery tray and interior light, Outside: Midnight Neutral

Alpha FXM 1100 UPS w/ SNMP or approved equivalent

Alpha Remote Battery Management System or approved equivalent

Intelligent Transportation System Equipment Standards

System Detection and Counters

Currux or approved equivalent

Data Aggregator / Travel Time Reader

BlueTOAD AC/Ethernet or approved equivalent

Closed Circuit Television Camera

HN-AIS-8300 PTZ Network Camera with HN-490BT POE injector or approved equivalent

Dynamic Message Signs

Daktronics – Vanguard VFC Controller or approved equivalent

Daktronics – GT6X Galaxy Displays with 8mm pixel pitch with platinum warranty

Southern Manufacturing – 334 ground mount cabinet, painted midnight neutral

(407) 828-2250

Network Equipment Standards

Managed Field Ethernet Switch

ITS Express 8042+ or approved equivalent

ITS Express 8012-24+ or approved equivalent

Fiber Optic Cable

Trunk Line – 96F single mode Corning Altos Cable (096EU4-T4701D20) or approved equivalent

Drop – 12F single mode Corning Altos Cable (012EU4-T4701D20) or approved equivalent

Splice Enclosure & Terminations

Corning Splice Closure (SCF-6C22-01F) or approved equivalent

Corning Splice Tray (SCF-ST-116) or approved equivalent

Corning Connector Housing (CCH-CP12-59) or approved equivalent

Corning Enclosure (CCH-01U) or approved equivalent

Fiber Drop

Custom Cable SC Pigtail or approved equivalent

Fusion Splice not to exceed 0.10 loss per splice

Corning Wall Mount Enclosure (SPH-01P) or approved equivalent

Pull Box & Conduit Standards

Traffic Signals Pull Box – Quazite or Equivalent

Traffic Signal - “DISTRICT TRAFFIC CONTROL”

Electrical – “DISTRICT TRAFFIC CONTROL”

13” x 24” x 12”

24” x 36” x 24”

Pull boxes and vaults shall conform to FDOT Standards Index 635

Fiber Optic Communications Pull Box– Quazite or Equivalent

Traffic Fiber – “DISTRICT TRAFFIC CONTROL”

24” x 36” x 24” – Every 500’ with 50’ Slack

36” Round x 24” Vault – Every 2000’ with 100’ Slack

Pull boxes and vaults shall conform to FDOT Standards Index 635

Conduit Type, Color & Labeling – 2” HDPE

Label: Pull Boxes 1-99, Conduits A-Z, Use Stamped Brass Label Tags starting from cabinet and working clockwise

Traffic Signals – Grey Conduit

Traffic Fiber – Orange Conduit

(407) 828-2250

Pull Lines, Tracer and Grounding

Mule tape and #12 tracer wires will be furnished & installed in each separate pathway with grounding rods installed every 2000’. Grounding rods are to be installed until a maximum of 25 ohms is achieved at each location.

As-Builts

Conduits and pullboxes shall be geolocated in CAD, Shapefile and PDF format

All splices, connection and terminations are to be noted in the as-builts

Ground rod locations are to be noted in the as-builts