J-19 Facil Srvy- Vol II-2.pdf
PDF 13 MB Posted
- Attached to
- Operation of the Gary Job Corps Center
- Solicitation number
- S11F6TX018
About this file
J-19 Facility Survey Vol II - part 2 of 3
View the file
Other files
| File | Type | Posted |
|---|---|---|
| AMENDMENT 3.doc | DOC document | |
| Amend 2.doc | DOC document | |
| J-8 Rev Utility Cost.xls | XLS spreadsheet | |
| Energy Sav Perf Contr.pdf | ||
| Enrgy Cost Sav Rep 2008.pdf | ||
| J-23 Inventory.pdf | ||
| J-17 Nat Staff Comp Report.xls | XLS spreadsheet | |
| J-20 Perf Report Cards.pdf | ||
| Amend1 J attch.doc | DOC document | |
| J-8 Utilities.pdf | ||
| J-13 EPMS Smry Rep.pdf | ||
| J-14 Site Map.pdf | ||
| J-22 CDSS Plan.doc | DOC document | |
| J-19 Facil Srvy- Vol I.pdf | ||
| J-12 Space Utlization Table.pdf | ||
| J-19 Facil Srvy- Vol II-3.pdf | ||
| J-19 Facil Srvy- Vol II-1.pdf | ||
| GaryRFP.doc | DOC document |
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Gary
Job Corps Center San Marcos, TX
Facility Planning Report Volume II (2 of 3)
Supporting Data Buildings: 07-160 thru 12-108
Structures: 00-100 thru 721PA Prototype Staff Housing and Carport
Final June 2009
Department of Labor/ Office of Job Corps
Gary
Job Corps Center San Marcos, TX
Facility Planning Report Volume II (2 of 3)
Supporting Data Buildings: 07-160 thru 12-108 Structures 00-100 thru 721PA
Prototype Staff Housing and Carport
Final June 2009
Building 2-110 Gym-Activity
CONTENTS
GARY JOB CORPS CENTER
FACILITY PLANNING REPORT
VOLUME I - Planning Strategy
• Existing Site Plan
• Center Statistics
INTRODUCTION
• Purpose
• Report Contents
EXECUTIVE SUMMARY
• Signifi cant Issues
• Recommended Plan
• Summary of Proposed Projects
A. EXISTING CONDITIONS
• Background
• General Site Conditions
• General Building Conditions
• Facility Assessment by Function
• Energy
• Environmental Issues
• Accessibility Standards
• Current and Completed Projects Since the Last Survey
• Health and Life Safety Issues
• Summary of Defi ciencies
B. RECOMMENDATIONS
• Status of the Previous (PY05) Plan
• Issues
• PY 08 Plan Overview
• National Projects
• Regional Projects
• Proposed Near Term Site Plan
• Implementation Plan
• Proposed Long Range Site Plan
• Summary List of National Projects
• Project Data Sheets
C. PLANNING ANALYSIS
• Purpose
• Planning Objectives and Assumptions
• Space Utilization Analysis
• Mission Dependency Site Plan
• Federal Real Property Asset Management
• Defi ciency Analysis
• Building Condition by Function
• Building Condition Site Plan
• Existing Site Plan (11x17)
VOLUME II - Supporting Data
• VICINITY MAP
• LOCATION MAP
• EXISTING SITE PLAN
D. DESCRIPTIONS
• Program Descriptions
— Square Footage Details (GSF by Building, Space Utilization Comparison, NSF by Building)
— Energy Management
— Environmental Management (Environmental Management Report, Asbestos Report and Radon Report)
• Site Descriptions
• Building Descriptions: 00-301 thru 07-153
• Existing Site Plan
• Building Descriptions: 07-160 thru 12-108
• Structures: 00-100 thru 721PA
• Prototype Staff Housing and Carport
• Existing Site Plan
E. DEFICIENCIES
F. CORRESPONDENCE AND REPORTS
• Center Review Brief
• Survey Brief
• RA and Student Facility Feedback Questionnaire
• Life Safety Defi ciencies Transmittal and List
• O & M Defi ciency List
• Active Warranty Report
• FRPC Performance Measures Matrix
• Existing Site Plan (11x17)
• Proposed Near Term Site Plan (11x17)
• Proposed Long Range Site Plan (11x17)
• Mission Dependency Site Plan (11x17)
• Building Condition Site Plan (11x17)
D Descriptions
Building Descriptions and Utilities Gary Job Corps Center
BUILDING 07-160 - WELDING
Building Descriptions Date: Jun. 19, 2009Center : Gary (00606) Page: 269 of 513
Building: 07-160 - WELDING
BUILDING ENVELOPE
Foundation RoofBuilding
Concrete Metal Steel
Metal Siding
Wall Roof None None
Metal Overhead - Metal Frame Metal Unit - Metal Frame
AccessibilityFeature
GSF NSF Year Built Use Group Historic Ownership#Floors
Factory/Industrial 14,455 11,560 1 Owned 1969 Unevaluated
REAL ESTATE
Access to Building
Ramps
Entrance
2nd Egress
Visual Alarm
Corridor/Aisle
Rooms
Stairs
Elevator
Restrooms
Drinking Fountain
Telephone
Yes
N/A
Yes
No
N/A
No
Yes
N/A
N/A
No
No
N/A
ACCESSIBILITY
Structural Systems1.
Exterior Walls2.
Insulation4.
Exterior Doors5.
Material
The roofing appears to be in good condition, therefore it should provide protection for another 6-years.
Drainage Year Life
Remaining Type Area Served
Metal Gutters and Downspouts 1969 6 Gable Entire Building
Comments:
3. Roof
Entire Building
Area Served
Page: 270 of 513
Building: 07-160 - WELDING
INTERIOR FINISH
Ceramic Tile Concrete Vinyl Tile
CMU Ceramic Tile Metal Siding Wood Paneling
Metal Units - Metal Frame Wood Unit - Metal Frame
Mechanical
Welding Fume Exhaust
Mechanical
Entire Building
Welding Booths
Restroom
Comments:
Comments:
Each pair of bays are provided general ventilation by a roof and a sidewall exhaust fan.
Each pair of bays has 31 welding booths. The fumes are captured at the booths by two utility set type exhaust fans (total of six fans) located outdoors on steel stands.
Ventilation Area Served
VERTICAL CIRCULATION
None
None
Acoustical Tile
Exhaust Ventilation
Number of Deficiencies = 3
Number of Deficiencies = 1
Windows6.
Floors1.
Interior Walls2.
3.
Interior Doors4.
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
The building's six bays are heated by three 100% makeup air units mounted on grade and each ducted to a pair of bays. The units were built by Trane in 1/2005 (#DFOA218DNFB1AJL32BBOAFM, 2200 MBH input and 17000 CFM each). The units serve to replace air exhausted by general and welding booth exhaust fans.
Comments:
HVAC
Heat1.
Gas-Fired Direct
Makeup Air Unit
None Electric Mechanical None Entire Building
Ventilation2. Number of Deficiencies = 1
Ceilings
Page: 271 of 513
Building: 07-160 - WELDING
The water is heated by an electric heater (Rheem #82V302, 4.5 kW, 30 gallon tank).Comments:
Cast Iron, PVC None None
Electric Water Cooler Fixed Emergency Eyewash Gang Sink Hose Bibb Lavatory Service Sink Urinal Water Closet (Flush Valve)
Gas (Natural)
None None ABC Type Fire Extinguisher
Comments: A total of eight overhead services, from four 3x50 kVA pole-mounted transformer banks, are provided to six 800A exterior wall-mounted service disconnects fused at 800A and a trough with three 200A disconnects fused at 200A. Each 800A disconnect is serving one of six welding shops. The 200A disconnects serve 225A main-lug-only panels providing for general loads for each pair of shops. All disconnects are located along the south exterior wall.
Copper Copper Electric None No
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
Evaporative Cooler
Packaged Direct
Expansion (Air Source)
Portable Unit
Window Unit
One-Pipe
None
Electric
Electric
Mechanical
Natural
None
None
Shop Area
Offices
Main Disconnect Switches 120/208V, 3-Phase, 4 Wire Panelboard Receptacles, Switches
Sprinkler System Stand Pipe System Fire Suppression
PLUMBING
Cooling in each bay is provided by portable evaporative coolers (General "Port-a-Cool" #PAC2K361S, built 5/2001).
Comments:
System Type
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
Water Distribution1.
Sanitary Distribution2.
Fixtures3.
Fuel Distribution4.
FIRE PROTECTION
ELECTRICAL SERVICES Number of Deficiencies = 5
3. Air Conditioning
Page: 272 of 513
Building: 07-160 - WELDING
FIRE ALARM
Comments: The fire alarm panel is a Faraday Firewatch 4.
Audible Alarm Control/Annunciator Panel Heat Detector Manual Pull Station
Connected to Main System None None None
Telephone Security Public Address Television
Comments: Recorded footcandle levels include natural light contribution.
None
LIGHTING
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
Offices
Classrooms
Storage/Warehouse-Active
Area Recommended Level
Recorded Level Light Type
Battery Backup Battery Backup
Emergency Exit
Number of Deficiencies = 1
GENERAL BUILDING CONDITION
Rating
Comments:
X Good Fair Poor
The welding fume exhaust systems are poorly designed, inefficient and very deteriorated. Six electrical service disconnects serving welding shops are deteriorated. Interior finishes are in poor condition.
Exterior Lighting1.
Interior Lighting2. Number of Deficiencies = 3
Emergency /Exit Lighting3. Number of Deficiencies = 2
COMMUNICATION
The facility condition is not impacting the functional use of the facility.
The facility condition IS impacting the functional use of the facility.
The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.
Electric Water Gas No NoNo
BUILDING UTILITY METERING
Structure: Good Exterior: Good Interior: Fair Mechanical: Poor Electrical: Fair
BUILDING 07-165 - VACANT
Page: 273 of 513
Building: 07-165 - VACANT
BUILDING ENVELOPE
Foundation RoofBuilding
Concrete Loadbearing Masonry Wood
CMU Masonry Wood Siding
Wall Roof None Batt
Metal Units - Metal Frame
AccessibilityFeature
GSF NSF Year Built Use Group Historic Ownership#Floors
Business 1,488 765 1 Owned 1999 Unevaluated
REAL ESTATE
Access to Building
Ramps
Entrance
2nd Egress
Visual Alarm
Corridor/Aisle
Rooms
Stairs
Elevator
Restrooms
Drinking Fountain
Telephone
Yes
N/A
Yes
Yes
Yes
Yes
Yes
N/A
N/A
Yes
Yes
N/A
ACCESSIBILITY
Structural Systems1.
Exterior Walls2.
Insulation4.
Exterior Doors5.
Material Drainage Year Life
Remaining Type Area Served
Asphalt Shingles Surface Run-off 1999 10 Hip Entire Building
Number of Deficiencies = 13. Roof
Page: 274 of 513
Building: 07-165 - VACANT
INTERIOR FINISH
Ceramic Tile Concrete Vinyl Tile
Ceramic Tile Drywall
Wood Units - Metal Frame
Natural Entire Building
Ventilation Area Served
VERTICAL CIRCULATION
None
Single Hung - Aluminum Frame; Double Glazing;
Acoustical Tile Gypsum Board
Exhaust Ventilation
Windows6.
Floors1.
Interior Walls2.
3.
Interior Doors4.
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
The unit was built by Ruud (#UJKAA048CK, 48 MBH, 12/1996). It is mounted on the roof.Comments:
HVAC
Heat1.
Packaged Heat Pump (Air
Source)
Single Duct None Electric Natural None Entire Building
Page: 275 of 513
Building: 07-165 - VACANT
The water heater was built by Rheem (#81V40DC, 4.5 kW, 40 gallon).Comments:
Cast Iron, PVC None None
Electric Water Cooler Hose Bibb Lavatory Urinal Water Closet (Flush Valve)
None
None None ABC Type Fire Extinguisher
Comments: Underground service is provided to a 200A exterior wall-mounted disconnect fused at 200A.
Copper Copper, Gavanized Steel
Electric None No
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
Packaged Heat Pump (Air
Source)
Single Duct None Electric Natural None Entire Building
Compact Fluorescent High Intensity Discharge (HID)
Comments: Building-mounted light fixtures are controlled by photocell.
LIGHTING
Main Disconnect Switch 120/208V, 1-Phase, 3 Wire Panelboard Receptacles, GFCI, Switches
Sprinkler System Stand Pipe System Fire Suppression
PLUMBING
The unit was built by Ruud (#UJKAA048CK, 4 ton, 12/1996). It is mounted on the roof.Comments:
System Type
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
Water Distribution1.
Sanitary Distribution2.
Fixtures3.
Fuel Distribution4.
FIRE PROTECTION
ELECTRICAL SERVICES Number of Deficiencies = 2
Exterior Lighting1. Number of Deficiencies = 1
Page: 276 of 513
Building: 07-165 - VACANT
FIRE ALARM
Comments: The fire alarm panel is a Faraday Firewatch 4.
Comments: The building is connected by wireless remote to the center LAN system for data communications.
Audible Alarm Control/Annunciator Panel Manual Pull Station Smoke Detector Visual Alarm
Connected to Main System None None None
Telephone Security Public Address Television
Comments: Recorded footcandle levels include natural light contribution. Incandescent fixtures are also utilized in some locations.
Incandescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
Incandescent
Compact Fluorescent
Storage Rooms
Classrooms
Offices
Corridors & Stairs
Equipment Rooms (Elec/Mech)
Toilets
Area Recommended Level
Recorded Level Light Type
Battery Backup Battery Backup
Emergency Exit
GENERAL BUILDING CONDITION
Rating X Good
Fair Poor
Interior Lighting2.
Emergency /Exit Lighting3. Number of Deficiencies = 1
COMMUNICATION
The facility condition is not impacting the functional use of the facility.
The facility condition IS impacting the functional use of the facility.
The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.
Electric Water Gas No N/ANo
Structure: Good Exterior: Good Interior: Good Mechanical: Good Electrical: Good
BUILDING 07-171 - HEALTH OCCUPATIONS
Page: 277 of 513
Building: 07-171 - HEALTH OCCUPATIONS
BUILDING ENVELOPE
Foundation RoofBuilding
Concrete Wood Wood
Wood Siding
Wall Roof None None
Metal Unit - Metal Frame Wood Unit - Wood Frame
AccessibilityFeature
GSF NSF Year Built Use Group Historic Ownership#Floors
Business 4,968 3,707 1 Owned 1942 Unevaluated
Comments: There are no visual alarms in toilet rooms.
REAL ESTATE
Access to Building
Ramps
Entrance
2nd Egress
Visual Alarm
Corridor/Aisle
Rooms
Stairs
Elevator
Restrooms
Drinking Fountain
Telephone
Yes
N/A
Yes
Yes
Yes
Yes
Yes
N/A
N/A
No
No
N/A
ACCESSIBILITY
Structural Systems1.
Exterior Walls2.
Insulation4.
Exterior Doors5. Number of Deficiencies = 1
Material
The roofing requires repairs of tabs blown off by high winds, but upon completion of repairs the roofing should provide protection for another 6 years.
Drainage Year Life
Remaining Type Area Served
Asphalt Shingles Surface Run-off 1990 6 Gable Entire Building
Number of Deficiencies = 1
Comments:
3. Roof
Page: 278 of 513
Building: 07-171 - HEALTH OCCUPATIONS
INTERIOR FINISH
Ceramic Tile Resilient Vinyl Tile
Ceramic Tile Drywall Wood Paneling
Wood Unit - Wood Frame
Mechanical Restroom
Ventilation Area Served
VERTICAL CIRCULATION
None
Casement - Aluminum Frame; Single Glazing; Single Hung - Aluminum Frame; Double Glazing;
Acoustical Tile Gypsum
Exhaust Ventilation
Windows6.
Floors1. Asbestos: Yes Number of Deficiencies = 1
Interior Walls2.
3.
Interior Doors4.
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
There are two furnaces (Carrier #58PAV090, 71 MBH output) serving this building.Comments:
HVAC
Heat1.
Gas-Fired Furnace
Single Duct None Electric Natural None Classrooms
Ventilation2. Number of Deficiencies = 2
Page: 279 of 513
Building: 07-171 - HEALTH OCCUPATIONS
The water heater (State #PV4020AT8F, 4.5 kW, 40 gallon) is electric.Comments:
Cast Iron, PVC None None
Electric Water Cooler Hose Bibb Lavatory Multi-Compartment Sink Service Sink Sink Urinal Water Closet (Flush Valve)
Gas (Natural)
None None ABC Type Fire Extinguisher
Comments: Overhead service is provided to a 400A disconnect fused at 400A, which in turn serves a 400A main-lug-only panelboard (Square D, NQO-424-4).
Copper Copper Electric None No
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
Split Heat Pump (Air
Source)
Portable Unit Refrigerant Electric Natural None Classrooms
None
LIGHTING
Main Disconnect Switch 120/208V, 3-Phase, 4 Wire Panelboard Receptacles, GFCI, Switches
Sprinkler System Stand Pipe System Fire Suppression
PLUMBING
There are two condensing units (Carrier #38AK008, 7-1/2 tons) serving this building.Comments:
System Type
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
Water Distribution1.
Sanitary Distribution2. Number of Deficiencies = 2
Fixtures3.
Fuel Distribution4.
FIRE PROTECTION
ELECTRICAL SERVICES Number of Deficiencies = 2
Exterior Lighting1.
Page: 280 of 513
Building: 07-171 - HEALTH OCCUPATIONS
FIRE ALARM
Comments: The fire alarm panel is an ESL 1500.
Audible Alarm Control/Annunciator Panel Heat Detector Manual Pull Station Visual Alarm
Connected to Main System None None TV with VCR
Telephone Security Public Address Television
Comments: Recorded footcandle levels include natural light contribution.
Comments: Photoluminescent exit signs are also utilized.
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
Compact Fluorescent
Offices
Classrooms
Storage Rooms
Toilets
Equipment Rooms (Elec/Mech)
Area Recommended Level
Recorded Level Light Type
Battery Backup Battery Backup
Emergency Exit
GENERAL BUILDING CONDITION
Rating
Comments:
X Good Fair Poor
The vinyl floor is dilapidated, rain penetrates through door edges, interior finishes in vacant areas are not in good condition.
Interior Lighting2.
Emergency /Exit Lighting3. Number of Deficiencies = 2
COMMUNICATION
The facility condition is not impacting the functional use of the facility.
The facility condition IS impacting the functional use of the facility.
The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.
Electric Water Gas No NoNo
Structure: Good Exterior: Fair Interior: Fair Mechanical: Good Electrical: Good
BUILDING 07-172 - VACANT
Page: 281 of 513
Building: 07-172 - VACANT
BUILDING ENVELOPE
Foundation RoofBuilding
Concrete Loadbearing Masonry Wood
CMU Masonry Wood Siding
Wall Roof None None
Metal Overhead - Metal Frame Metal Units - Metal Frame
AccessibilityFeature
GSF NSF Year Built Use Group Historic Ownership#Floors
Business 2,046 1,141 1 Owned 1995 Unevaluated
REAL ESTATE
Access to Building
Ramps
Entrance
2nd Egress
Visual Alarm
Corridor/Aisle
Rooms
Stairs
Elevator
Restrooms
Drinking Fountain
Telephone
Yes
N/A
Yes
No
Yes
No
No
N/A
N/A
N/A
N/A
N/A
ACCESSIBILITY
Structural Systems1.
Exterior Walls2.
Insulation4.
Exterior Doors5.
Material Drainage Year Life
Remaining Type Area Served
Asphalt Shingles
Asphalt Shingles
Surface Run-off
Surface Run-off
Gable
Gable
Entire Building
Storage Addition
3. Roof
Page: 282 of 513
Building: 07-172 - VACANT
INTERIOR FINISH
Concrete
CMU
Metal Unit - Metal Frame
Natural
Mechanical
Entire Building
Paint Booth
Comments: When a paint booth is operating the building is ventilated. Otherwise, it is natural.
Ventilation Area Served
VERTICAL CIRCULATION
None
None
Exposed structure
Exhaust Ventilation
Windows6.
Floors1.
Interior Walls2.
3.
Interior Doors4.
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
The paint booths receive heated makeup air.Comments:
HVAC
Heat1.
Gas-Fired Furnace
Makeup Air Unit
None Electric Mechanical None Shop Area
Page: 283 of 513
Building: 07-172 - VACANT
Cast Iron, PVC None None
Emergency Eye Wash Hose Bibb Service Sink
Gas (Natural)
None None ABC Type Fire Extinguisher, Dry Chemical
Comments: Underground service is provided to two exterior-mounted adjacent disconnects, each rated and fused at 200A.
None Copper None None No
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
None None None None Natural None Entire Building
High Intensity Discharge (HID)
Comments: Building-mounted light fixtures are controlled by photocell.
LIGHTING
Main Disconnect Switches 120/208V, 1-Phase, 3 Wire Panelboard Receptacles, GFCI, Switches
Sprinkler System Stand Pipe System Fire Suppression
PLUMBING
System Type
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
Water Distribution1.
Sanitary Distribution2.
Fixtures3.
Fuel Distribution4.
Number of Deficiencies = 1FIRE PROTECTION
ELECTRICAL SERVICES
Page: 284 of 513
Building: 07-172 - VACANT
FIRE ALARM
Comments: The fire alarm panel is a Faraday Firewatch 2.
Audible Alarm Control Panel Heat Detector Manual Pull Station Visual Alarm
None None None None
Telephone Security Public Address Television
Comments: Recorded footcandle levels include natural light contribution.
Comments: Three tritium gas exit signs are also utilized. These expired in 1994.
T8 - Fluorescent
T12 - Fluorescent
T8 - Fluorescent
Classrooms
Storage Rooms
Equipment Rooms (Elec/Mech)
Area Recommended Level
Recorded Level Light Type
Battery Backup Battery Backup
Emergency Exit
GENERAL BUILDING CONDITION
Rating X Good
Fair Poor
Interior Lighting2.
Emergency /Exit Lighting3. Number of Deficiencies = 1
COMMUNICATION
The facility condition is not impacting the functional use of the facility.
The facility condition IS impacting the functional use of the facility.
The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.
Electric Water Gas No NoNo
BUILDING 07-173 - HEALTH OCCUPATIONS
Page: 285 of 513
Building: 07-173 - HEALTH OCCUPATIONS
BUILDING ENVELOPE
Foundation RoofBuilding
Concrete Wood Wood
T111 Siding
Wall Roof None Batt
Metal Unit - Metal Frame
AccessibilityFeature
GSF NSF Year Built Use Group Historic Ownership#Floors
Business 4,924 3,990 1 Owned 1942 Unevaluated
REAL ESTATE
Access to Building
Ramps
Entrance
2nd Egress
Visual Alarm
Corridor/Aisle
Rooms
Stairs
Elevator
Restrooms
Drinking Fountain
Telephone
Yes
Yes
Yes
Yes
Yes
Yes
Yes
N/A
N/A
Yes
No
N/A
ACCESSIBILITY
Structural Systems1.
Exterior Walls2. Number of Deficiencies = 1
Insulation4.
Exterior Doors5.
Material
The roofing has been damaged from high winds and if not repaired, the roofing won't provide protection for more than one year and will need to be replaced. If the roofing is repaired, it should provide protection for another 6 years.
Drainage Year Life
Remaining Type Area Served
Asphalt Shingles Surface Run-off 1990 1 Gable Entire Building
Number of Deficiencies = 1
Comments:
3. Roof
Page: 286 of 513
Building: 07-173 - HEALTH OCCUPATIONS
INTERIOR FINISH
Ceramic Tile Concrete Vinyl Tile
Ceramic Tile Drywall
Metal Units - Metal Frame Wood Units - Metal Frame
Mechanical
Mechanical
Shop Area
Restroom
Ventilation Area Served
VERTICAL CIRCULATION
None
Single Hung - Aluminum Frame; Single Glazing;
Acoustical Tile
Exhaust Ventilation
Windows6.
Floors1.
Interior Walls2.
3.
Interior Doors4.
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
The heat pump (Ruud #UPMA036JAZ, 36 MBH output) is roof-mounted.
The two units (Bryant, 3000 CFM) are mounted on the roof.
Comments:
Comments:
HVAC
Heat1.
Split Heat Pump (Air
Source)
Gas-Fired Packaged
Single Duct
Single Duct
Refrigerant
None
Electric
Electric
Natural
Natural
None
None
Classrooms and Offices
Entire Building
Page: 287 of 513
Building: 07-173 - HEALTH OCCUPATIONS
Cast Iron, PVC None None
Electric Water Cooler Fixed Emergency Eyewash Hose Bibb Lavatory Service Sink Urinal Water Closet (Flush Valve)
Gas (Natural)
None None None
Comments: Underground service is provided to a 225A exterior wall-mounted main circuit breaker located at the south exterior wall. A second overhead service is provided to a 100A main-lug-only loadcenter utilized for new HVAC equipment. A third overhead service is provided to a disconnect switch rated and fused at 100A.
The 100A loadcenter and 100A disconnect switch are located along the east exterior wall.
Copper Copper Electric None No
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
Split Heat Pump (Air
Source)
Packaged Direct
Expansion (Air Source)
Single Duct
Single Duct
Refrigerant
None
Electric
Electric
Natural
Natural
None
None
Classrooms and Offices
Entire Building
Main Circuit Breaker 120/208V, 3-Phase, 4 Wire Panelboard Receptacles, Switches
Sprinkler System Stand Pipe System Fire Suppression
PLUMBING
The heat pump (Ruud #UPMA036JAZ, 3 tons) is roof-mounted.
The two units (Bryant, 7-1/2 ton) are mounted on the roof.
Comments:
Comments:
System Type
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
Water Distribution1.
Sanitary Distribution2.
Fixtures3.
Fuel Distribution4.
Number of Deficiencies = 1FIRE PROTECTION
ELECTRICAL SERVICES Number of Deficiencies = 1
Page: 288 of 513
Building: 07-173 - HEALTH OCCUPATIONS
FIRE ALARM
Comments: The fire alarm panel is a Silent Knight IFP-50.
Comments: The building is connected to the center LAN system for data communications.
Audible Alarm Control/Annunciator Panel Heat Detector Manual Pull Station Smoke Detector Visual Alarm
Connected to Main System None None TV with VCR
Telephone Security Public Address Television
Comments: Recorded footcandle levels include natural light contribution. Occupancy sensors are incorporated for control.
Comments: Photoluminescent exit signs are also utilized.
High Intensity Discharge (HID)
Comments: Building-mounted light fixtures are controlled by photocell.
LIGHTING
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
Offices
Classrooms
Corridors & Stairs
Toilets
Storage Rooms
Area Recommended Level
Recorded Level Light Type
Battery Backup Battery Backup
Emergency Exit
GENERAL BUILDING CONDITION
Rating
Comments:
X Good Fair Poor
The roof shingles have been damaged by high winds.
Exterior Lighting1.
Interior Lighting2.
Emergency /Exit Lighting3.
COMMUNICATION
The facility condition is not impacting the functional use of the facility.
The facility condition IS impacting the functional use of the facility.
The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.
Electric Water Gas No NoNo
Structure: Good Exterior: Fair Interior: Good Mechanical: Good Electrical: Good
BUILDING 07-174 - HEALTH OCCUPATIONS
Page: 289 of 513
Building: 07-174 - HEALTH OCCUPATIONS
BUILDING ENVELOPE
Foundation RoofBuilding
Concrete Wood Wood
T111 Siding
Wall Roof None None
Metal Unit - Metal Frame
AccessibilityFeature
GSF NSF Year Built Use Group Historic Ownership#Floors
Business 5,095 4,400 1 Owned 1942 Unevaluated
Comments: The women's restroom is accessible and used by disabled persons of both genders.
REAL ESTATE
Access to Building
Ramps
Entrance
2nd Egress
Visual Alarm
Corridor/Aisle
Rooms
Stairs
Elevator
Restrooms
Drinking Fountain
Telephone
Yes
N/A
Yes
Yes
Yes
Yes
Yes
N/A
N/A
Yes
No
N/A
ACCESSIBILITY
Structural Systems1.
Exterior Walls2. Number of Deficiencies = 1
Insulation4.
Exterior Doors5.
Material
The roofing appears to be in good condition, therefore it should provide protection for another 6 years.
Drainage Year Life
Remaining Type Area Served
Asphalt Shingles Surface Run-off 1990 6 Gable Entire Building
Comments:
3. Roof
Page: 290 of 513
Building: 07-174 - HEALTH OCCUPATIONS
INTERIOR FINISH
Ceramic Tile Concrete Vinyl Tile
Ceramic Tile Drywall Plywood
Wood Unit - Metal Frame
Mechanical
Mechanical
Restroom
Entire Building
Ventilation Area Served
VERTICAL CIRCULATION
None
Single Hung - Aluminum Frame; Single Glazing; Sliding - Aluminum Frame; Single Glazing;
Acoustical Tile
Exhaust Ventilation
Windows6.
Floors1.
Interior Walls2.
3.
Interior Doors4.
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
The heat pump (Ruud #UPMA036JAZ, 36 MBH, built 4/1994) is located on the roof.
The multi-purpose room is served by a roof-mounted unit (Trane).
Comments:
Comments:
HVAC
Heat1.
Split Heat Pump (Air
Source)
Gas-Fired Packaged
Single Duct
Single Duct
Refrigerant
None
Electric
Electric
Natural
Natural
None
None
Classrooms and Offices
Classrooms and Offices
Page: 291 of 513
Building: 07-174 - HEALTH OCCUPATIONS
Cast Iron, PVC None None
Electric Water Cooler Hose Bibb Lavatory Service Sink Urinal Water Closet (Flush Valve)
Gas (Natural)
None None ABC Type Fire Extinguisher
Comments: Underground service is provided to a 225A exterior wall-mounted main circuit breaker (MCB), which in turn serves a 250A panelboard (Siemens, S1C42Q225ATS). A second overhead service is provided to a 100A loadcenter with a 100A MCB utilized for new HVAC equipment.
Copper Copper Electric None No
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
Split Heat Pump (Air
Source)
Packaged Direct
Expansion (Air Source)
Single Duct
Single Duct
Refrigerant
None
Electric
Electric
Natural
Natural
None
None
Classrooms and Offices
Classrooms and Offices
Main Circuit Breaker 120/208V, 3-Phase, 4 Wire Panelboard Receptacles, GFCI, Switches
Sprinkler System Stand Pipe System Fire Suppression
PLUMBING
The heat pump (Ruud #UPMA036JAZ, 36 MBH, built 4/1994) is located on the roof.
The multi-purpose room is served by a roof-mounted unit (Trane).
Comments:
Comments:
System Type
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
Water Distribution1.
Sanitary Distribution2.
Fixtures3.
Fuel Distribution4.
FIRE PROTECTION
ELECTRICAL SERVICES
Page: 292 of 513
Building: 07-174 - HEALTH OCCUPATIONS
FIRE ALARM
Comments: The fire alarm panel is a Silent Knight IFP-50.
Comments: The building is connected to the center LAN system for data communications.
Audible Alarm Control/Annunciator Panel Duct Smoke Detector Heat Detector Manual Pull Station Smoke Detector Visual Alarm
Connected to Main System None None TV with VCR
Telephone Security Public Address Television
Comments: Recorded footcandle levels include natural light contribution. Occupancy sensors are incorporated for control.
Comments: One battery backup exit sign is also utilized.
High Intensity Discharge (HID)
Comments: Building-mounted light fixtures are controlled by photocell.
LIGHTING
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
Incandescent
Classrooms
Offices
Storage Rooms
Toilets
Equipment Rooms (Elec/Mech)
Area Recommended Level
Recorded Level Light Type
Battery Backup Photoluminescent
Emergency Exit
Number of Deficiencies = 1
GENERAL BUILDING CONDITION
Rating
Comments:
X Good Fair Poor
The wood siding is deteriorated.
Exterior Lighting1.
Interior Lighting2. Number of Deficiencies = 1
Emergency /Exit Lighting3. Number of Deficiencies = 1
COMMUNICATION
The facility condition is not impacting the functional use of the facility.
The facility condition IS impacting the functional use of the facility.
The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.
Electric Water Gas No NoNo
Structure: Good Exterior: Fair Interior: Good Mechanical: Good Electrical: Good
BUILDING 07-176 - GARY DELUXE HOME ECON
Page: 293 of 513
Building: 07-176 - GARY DELUXE HOME ECON
BUILDING ENVELOPE
Foundation RoofBuilding
Concrete Wood Wood
T111 Siding
Wall Roof None None
Comments: Double ceiling and air gap in between provide some insulation.
Metal Units - Metal Frame Wood Unit - Wood Frame
AccessibilityFeature
GSF NSF Year Built Use Group Historic Ownership#Floors
Business 4,630 3,511 1 Owned 1942 Unevaluated
REAL ESTATE
Access to Building
Ramps
Entrance
2nd Egress
Visual Alarm
Corridor/Aisle
Rooms
Stairs
Elevator
Restrooms
Drinking Fountain
Telephone
Yes
N/A
Yes
N/A
N/A
Yes
Yes
N/A
N/A
Yes
No
N/A
ACCESSIBILITY
Structural Systems1.
Exterior Walls2.
Insulation4.
Exterior Doors5. Number of Deficiencies = 1
Material Drainage Year Life
Remaining Type Area Served
Asphalt Shingles Surface Run-off 2004 15 Gable Entire Building
3. Roof
Page: 294 of 513
Building: 07-176 - GARY DELUXE HOME ECON
INTERIOR FINISH
Concrete Quarry Tile Vinyl Tile
Drywall Wood Paneling
Wood Unit - Wood Frame
Mechanical
Mechanical
Restroom
Kitchen
Comments: There is a roof-mounted exhaust fan (Captive-Aire #NCA14FA, 1 HP, built 3/2005) that serves the 7'-0" x 6'-0" kitchen hood. It is interlocked with a roof-mounted makeup air unit.
Ventilation Area Served
VERTICAL CIRCULATION
None
Single Hung - Wood Frame; Single Glazing;
Acoustical Tile Gypsum
Exhaust Ventilation
Number of Deficiencies = 1
Number of Deficiencies = 1
Windows6.
Floors1.
Interior Walls2.
3.
Interior Doors4.
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
There are two Trane units (#YSC120A3RLA, 120 MBH output) outside on steel stands and ducted into the building.
There are two electric wall heaters.
Comments:
Comments:
HVAC
Heat1.
Gas-Fired Packaged
Electric Resistance
Single Duct
Unit Heater
None
None
Electric
Electric
Natural
Natural
None
None
Entire Building
Offices
Ventilation2.
Page: 295 of 513
Building: 07-176 - GARY DELUXE HOME ECON
The water heater is by Rheem (#GN75125, 100 MBH output, 75 gallons, built 6/2004).Comments:
Cast Iron, PVC Outdoor None
Electric Water Cooler Hose Bibb Lavatory Multi-Compartment Sink Shower Sink Urinal Water Closet (Flush Valve)
Gas (Natural)
None None ABC Type Fire Extinguisher, Dry Chemical
Comments: Overhead service is provided to a trough with two 150A main circuit breakers, which in turn serve two 200A main-lug-only loadcenters (Square D, QOC-43OL).
Copper, Galvanized Steel
Copper, PVC Gas-Fired None No
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
Packaged Direct
Expansion (Air Source)
Single Duct None Electric Natural None Entire Building
High Intensity Discharge (HID)
Comments: Building-mounted light fixtures are controlled by photocell.
LIGHTING
Main Circuit Breakers 120/208V, 3-Phase, 4 Wire Loadcenter Receptacles, GFCI, Switches
Sprinkler System Stand Pipe System Fire Suppression
PLUMBING
There are two Trane units (#YSC120A3RLA, 10 tons each) outside on steel stands and ducted into the building.
Comments:
System Type
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
Water Distribution1.
Sanitary Distribution2.
Fixtures3.
Fuel Distribution4.
FIRE PROTECTION
ELECTRICAL SERVICES
Page: 296 of 513
Building: 07-176 - GARY DELUXE HOME ECON
FIRE ALARM
Comments: The fire alarm panel is an ESL 1500.
Audible Alarm Control/Annunciator Panel Heat Detector Manual Pull Station Visual Alarm
Connected to Main System Closed Circuit TV None Local Cable Company
Telephone Security Public Address Television
Comments: Recorded footcandle levels include natural light contribution.
Comments: Photoluminescent exit sign is also utilized.
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
Incandescent
Storage Rooms
Classrooms
Dining/Lunch Rooms
Food Preparation
Toilets
Equipment Rooms (Elec/Mech)
Area Recommended Level
Recorded Level Light Type
Battery Backup Battery Backup
Emergency Exit
Number of Deficiencies = 2
GENERAL BUILDING CONDITION
Rating X Good
Fair Poor
Interior Lighting2. Number of Deficiencies = 2
Emergency /Exit Lighting3. Number of Deficiencies = 2
COMMUNICATION
The facility condition is not impacting the functional use of the facility.
The facility condition IS impacting the functional use of the facility.
The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.
Electric Water Gas No NoNo
BUILDING 07-178 - AUTOMOTIVE STORAGE
Page: 297 of 513
Building: 07-178 - AUTOMOTIVE STORAGE
BUILDING ENVELOPE
Foundation RoofBuilding
Concrete Metal Steel
Metal Siding
Wall Roof None None
Metal Overhead - Metal Frame Metal Unit - Metal Frame
AccessibilityFeature
GSF NSF Year Built Use Group Historic Ownership#Floors
Storage 3,510 3,300 1 Owned 1968 Unevaluated
REAL ESTATE
Access to Building
Ramps
Entrance
2nd Egress
Visual Alarm
Corridor/Aisle
Rooms
Stairs
Elevator
Restrooms
Drinking Fountain
Telephone
Yes
N/A
No
No
N/A
N/A
Yes
N/A
N/A
N/A
N/A
N/A
ACCESSIBILITY
Structural Systems1.
Exterior Walls2.
Insulation4.
Exterior Doors5.
Material Drainage Year Life
Remaining Type Area Served
Metal Surface Run-off 1997 28 `` Entire Building
3. Roof
Page: 298 of 513
Building: 07-178 - AUTOMOTIVE STORAGE
INTERIOR FINISH
Concrete
Exposed Structure
None
Mechanical Entire Building
Comments: There is one small sidewall exhaust fan ventilating the building.
Ventilation Area Served
VERTICAL CIRCULATION
None
Single Hung - Aluminum Frame; Single Glazing;
None None None None Natural None Entire Building
Exposed Structure
Exhaust Ventilation
Windows6.
Floors1.
Interior Walls2.
3.
Interior Doors4.
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
HVAC
Heat1.
Gas-Fired Unit Heater None Electric Natural None Entire Building
Ventilation2.
System Type
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
Page: 299 of 513
Building: 07-178 - AUTOMOTIVE STORAGE
None None None
None
Gas (Natural)
None None None
Comments: Overhead service is provided to a 100A disconnect fused at 100A.
None None None None No
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
Comments: As of the February 2009 Facility Survey, the lighting in this building was turned off at the loadcenter.
None
LIGHTING
T8 - Fluorescent0Storage/Warehouse-Inactive 10
Area Recommended Level
Recorded Level Light Type
None Battery Backup
Main Disconnect Switch 120/208V, 1-Phase, 3 Wire Loadcenter Receptacles, Switches
Sprinkler System Stand Pipe System Fire Suppression
Emergency Exit
PLUMBING
Water Distribution1.
Sanitary Distribution2.
Fixtures3.
Fuel Distribution4.
FIRE PROTECTION
ELECTRICAL SERVICES
Exterior Lighting1.
Interior Lighting2.
Emergency /Exit Lighting3.
Page: 300 of 513
Building: 07-178 - AUTOMOTIVE STORAGE
FIRE ALARM
None
Connected to Main System None None None
Telephone Security Public Address Television
GENERAL BUILDING CONDITION
Rating X Good
Fair Poor
COMMUNICATION
The facility condition is not impacting the functional use of the facility.
The facility condition IS impacting the functional use of the facility.
The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.
Electric Water Gas N/A NoNo
BUILDING 07-180 - TCU / VACANT
Page: 301 of 513
Building: 07-180 - TCU / VACANT
BUILDING ENVELOPE
Foundation RoofBuilding
Concrete Structural Steel Steel
CMU Masonry Metal Siding Wood Siding
Wall Roof Batt Batt
Metal Units - Metal Frame
AccessibilityFeature
GSF NSF Year Built Use Group Historic Ownership#Floors
Business 9,851 7,190 1 Owned 1989 Unevaluated
Comments: There are no visual alarms in toilet rooms.
REAL ESTATE
Access to Building
Ramps
Entrance
2nd Egress
Visual Alarm
Corridor/Aisle
Rooms
Stairs
Elevator
Restrooms
Drinking Fountain
Telephone
Yes
N/A
Yes
Yes
Yes
Yes
Yes
N/A
N/A
Yes
Yes
N/A
ACCESSIBILITY
Structural Systems1.
Exterior Walls2.
Insulation4.
Exterior Doors5.
Material Drainage Year Life
Remaining Type Area Served
Metal Surface Run-off 1989 20 Gable Entire Building
3. Roof
Page: 302 of 513
Building: 07-180 - TCU / VACANT
INTERIOR FINISH
Ceramic Tile Concrete Vinyl Tile
CMU Ceramic Tile Drywall
Metal Units - Metal Frame Wood Unit - Metal Frame
VERTICAL CIRCULATION
None
Double Hung - Aluminum Frame; Double Glazing; Single Hung - Aluminum Frame; Double Glazing;
Acoustical Tile Exposed structure Gypsum Board
Number of Deficiencies = 1
Windows6.
Floors1.
Interior Walls2.
3. Number of Deficiencies = 1
Interior Doors4.
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
The corridor and restrooms are served by hot water unit heaters.
There are eight fan-coil units fitted with hot water coils.
The furnace was built by Carrier.
Comments:
Comments:
Comments:
HVAC
Heat1.
Gas-Fired Hot Water Boiler
Gas-Fired Hot Water Boiler
Gas-Fired Furnace
Unit Heater
Single Duct
Single Duct
Two-Pipe
Two-Pipe
None
Electric
Electric
Electric
Natural
Natural
Natural
None
None
None
Common Area
Classrooms and Offices
Offices
Page: 303 of 513
Building: 07-180 - TCU / VACANT
Mechanical
Mechanical
Restroom
Corridor
The water heater was built by Rheem (#22V30F, 32 MBH input, 29 gallons, 2/2008).Comments:
Cast Iron/PVC None None
Electric Water Cooler Lavatory Mop Sink Urinal Wall Hydrant Water Closet (Flush Valve)
Gas (Natural)
None None ABC Type Fire Extinguisher
Ventilation Area Served
Copper Copper, Galvanized Steel
Gas-Fired None No
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
Split Direct Expansion (Air
Source)
Single Duct Refrigerant Electric Natural None Classrooms and Offices
Sprinkler System Stand Pipe System Fire Suppression
PLUMBING
Exhaust Ventilation
There are nine condensing units located at grade level around the building. There are four by Lennox (#HS16511U8P, 4 Tons, built 10/1991), three by Trane (two-#TTB724B, 2 tons each built 1988 and a 2TTB0048A, 4 tons, built 6/2005), one by Carrier (#24 ABA336A310, 3 tons) and one by Nordyne (#JS3BA048KA, 4 tons).
Comments:
Number of Deficiencies = 1
Ventilation2.
System Type
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
Water Distribution1.
Sanitary Distribution2.
Fixtures3.
Fuel Distribution4.
FIRE PROTECTION
Page: 304 of 513
Building: 07-180 - TCU / VACANT
Comments: Underground service is provided to a 600A main switchboard (Square D, I-Line, E1) with a 500A main circuit breaker. The switchboard has (6) 100A and (1) 250A circuit breakers, and serves six 225A main-lug-only (MLO) panels located one in each shop and one two-section 225A MLO panel located in the mechanical room and serving north building's end.
FIRE ALARM
Comments: The fire alarm panel is a Silent Knight 2224.
Comments: The building is connected to the center LAN system for data communications.
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
Audible Alarm Control/Annunciator Panel Heat Detector Manual Pull Station Smoke Detector Visual Alarm
Connected to Main System None None Local Cable Company
Telephone Security Public Address Television
Comments: Recorded footcandle levels include natural light contribution.
Compact Fluorescent High Intensity Discharge (HID)
Comments: Building-mounted light fixtures are controlled by photocell.
LIGHTING
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
Offices
Classrooms
Storage Rooms
Toilets
Equipment Rooms (Elec/Mech)
Area Recommended Level
Recorded Level Light Type
Battery Backup Battery Backup
Switchboard 120/208V, 3-Phase, 4 Wire Panelboard Receptacles, GFCI, Switches
Emergency Exit
Number of Deficiencies = 1
ELECTRICAL SERVICES
Exterior Lighting1.
Interior Lighting2.
Emergency /Exit Lighting3. Number of Deficiencies = 2
COMMUNICATION
Electric Water Gas No NoNo
Page: 305 of 513
Building: 07-180 - TCU / VACANT
GENERAL BUILDING CONDITION
Rating X Good
Fair Poor
The facility condition is not impacting the functional use of the facility.
The facility condition IS impacting the functional use of the facility.
The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.
BUILDING 07-200 - COMMUNITY LIFE / VACANT / HUB
Page: 306 of 513
Building: 07-200 - COMMUNITY LIFE / VACANT / HUB
BUILDING ENVELOPE
Foundation RoofBuilding
Concrete Structural Steel Steel
CMU Masonry
Wall Roof Batt Rigid
Metal Units - Metal Frame
AccessibilityFeature
GSF NSF Year Built Use Group Historic Ownership#Floors
Business 10,340 6,902 1 Owned 1990 Unevaluated
REAL ESTATE
Access to Building
Ramps
Entrance
2nd Egress
Visual Alarm
Corridor/Aisle
Rooms
Stairs
Elevator
Restrooms
Drinking Fountain
Telephone
Yes
N/A
Yes
Yes
Yes
Yes
Yes
N/A
N/A
Yes
Yes
N/A
ACCESSIBILITY
Structural Systems1.
Exterior Walls2.
Insulation4.
Exterior Doors5.
Material Drainage Year Life
Remaining Type Area Served
Metal Gutters and Downspouts 1990 21 Gable Entire Building
3. Roof
Page: 307 of 513
Building: 07-200 - COMMUNITY LIFE / VACANT / HUB
INTERIOR FINISH
Ceramic Tile Concrete Vinyl Tile
CMU Ceramic Tile Drywall
Wood Unit - Metal Frame
Mechanical Restroom
Ventilation Area Served
VERTICAL CIRCULATION
None
Single Hung - Aluminum Frame; Double Glazing;
Acoustical Tile Gypsum Board
Exhaust Ventilation
Number of Deficiencies = 2
Windows6.
Floors1.
Interior Walls2.
3.
Interior Doors4.
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
There are six vertical, upflow furnaces manufacturered by Bryant, Trane and York.Comments:
HVAC
Heat1.
Gas-Fired Furnace
Single Duct None Electric Mechanical None Entire Building
Page: 308 of 513
Building: 07-200 - COMMUNITY LIFE / VACANT / HUB
The water heater was built by A.O. Smith (#BT120880, 96 MBH output, 75 gallon tank).Comments:
Cast Iron/PVC None None
Electric Water Cooler Hose Bibb Lavatory Mop Sink Sink Urinal Water Closet (Flush Valve)
Gas (Natural)
None None ABC Type Fire Extinguisher
Comments: Underground service is provided to a 600A switch-and-fuse type main switchboard (Westinghouse, FDP- 326R, built 4/90). The switchboard has four 60A, two 100A and two 200A switches, and serves two 225A main-lug-only (MLO) panels (Westinghouse, PRL1, built 4/90), five HVAC units and a kiln.
Copper Copper Gas-Fired None No
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
Split Direct Expansion (Air
Source)
Single Duct Refrigerant Electric Mechanical None Entire Building
Switchboard 120/208V, 3-Phase, 4 Wire Panelboard Receptacles, GFCI, Switches
Sprinkler System Stand Pipe System Fire Suppression
PLUMBING
The cooling is produced by six condensing units built by three manufacturers (a Trane #2TTB0036A1, 3 tons, built 8/2003; three Trane #TTA090A300FA, 7-1/2 tons each, built 2002 & 2004; a Rheem #RAWD076CAZ, 7-1/2 tons, built 6/2001 and a Bryant #563CNX036D, 3 tons). Each of these units operate in conjunction with one of the six furnaces that each have a DX evaporator coil mounted on the discharge.
Comments:
System Type
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
Water Distribution1.
Sanitary Distribution2.
Fixtures3.
Fuel Distribution4.
FIRE PROTECTION
ELECTRICAL SERVICES Number of Deficiencies = 2
Page: 309 of 513
Building: 07-200 - COMMUNITY LIFE / VACANT / HUB
FIRE ALARM
Comments: The fire alarm panel is an Edwards 6616.
Comments: This building houses a LAN server room for data communications for most 07-000 series buildings.
This server reports back to the main server at Building 05-214. 25 cameras are used to monitor the center from a color monitor located in the coordinator's office. Additionally, security systems for intrusion detection, installed in Payroll Building 06-106, Center Administration Building 06-104, and several other buildings, report alarm status to this building.
Audible Alarm Control/Annunciator Panel Duct Smoke Detector Heat Detector Manual Pull Station Smoke Detector Visual Alarm
Connected to Main System Color Monitor None Local Cable Company
Telephone Security Public Address Television
Comments: Recorded footcandle levels include natural light contribution.
High Intensity Discharge (HID) Incandescent
Comments: Building-mounted light fixtures are controlled by photocell.
LIGHTING
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
Offices
Conference Rooms
Corridors & Stairs
Storage Rooms
Toilets
Equipment Rooms (Elec/Mech)
Area Recommended Level
Recorded Level Light Type
Selected Lighting w/ Battery Battery Backup
Emergency Exit
Number of Deficiencies = 1
GENERAL BUILDING CONDITION
Rating X Good
Fair Poor
Exterior Lighting1. Number of Deficiencies = 1
Interior Lighting2.
Emergency /Exit Lighting3. Number of Deficiencies = 1
COMMUNICATION
The facility condition is not impacting the functional use of the facility.
The facility condition IS impacting the functional use of the facility.
The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.
Electric Water Gas No NoNo
BUILDING 07-216 - DORMITORY
Page: 310 of 513
Building: 07-216 - DORMITORY
BUILDING ENVELOPE
Foundation RoofBuilding
Concrete Loadbearing Masonry Steel
Brick Masonry
Wall Roof Batt Batt
Metal Units - Metal Frame
AccessibilityFeature
GSF NSF Year Built Use Group Historic Ownership#Floors
Residential 9,576 7,356 1 Owned 1974 Unevaluated
Comments: There are no visual alarms in laundry and toilet/shower rooms.
REAL ESTATE
Access to Building
Ramps
Entrance
2nd Egress
Visual Alarm
Corridor/Aisle
Rooms
Stairs
Elevator
Restrooms
Drinking Fountain
Telephone
Yes
N/A
Yes
Yes
Yes
Yes
Yes
N/A
N/A
No
No
Yes
ACCESSIBILITY
Structural Systems1.
Exterior Walls2.
Insulation4.
Exterior Doors5. Number of Deficiencies = 2
Material Drainage Year Life
Remaining Type Area Served
Metal
Metal
Gutters and Downspouts
Surface Run-off
Gable
Mansard
Entire Building
Building Periphery
3. Roof
Page: 311 of 513
Building: 07-216 - DORMITORY
INTERIOR FINISH
Concrete Terrazzo Vinyl Tile
Ceramic Tile Drywall FRP Wood paneling
Metal Unit - Metal Frame Wood Units - Metal Frame
Mechanical Toilet/Shower
Ventilation Area Served
VERTICAL CIRCULATION
None
Casement - Aluminum Frame; Double Glazing; Single Hung - Aluminum Frame; Single Glazing;
Exposed Structure Gypsum Board
Exhaust Ventilation
Windows6.
Floors1.
Interior Walls2. Number of Deficiencies = 1
3.
Interior Doors4.
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
The heating unit is a Reznor duct heater (approx. 350 MBH) mounted in the return airsteam. It is equipped with a powered flue vent and outdoor air intake. The air is circulated by a Carrier (#40RM024B511GC, 8000 CFM) air handling unit.
Comments:
HVAC
Heat1.
Gas-Fired Furnace
Single Duct None Electric Mechanical None Entire Building
Ventilation2. Number of Deficiencies = 4
Page: 312 of 513
Building: 07-216 - DORMITORY
The water is heated by two water heaters (each a State #SBF100199NET1, 160 MBH output, 100 gallon tank, built 1995).
Comments:
Cast Iron/PVC None None
Electric Water Cooler Hose Bibb Lavatory Service Sink Shower Urinal Water Closet (Flush Valve)
Gas (Natural)
None None ABC Type Fire Extinguisher
Comments: Underground service is provided to a 400A disconnect fused at 400A located in the mechanical/electrical room. This disconnect serves through the trough two 100A and one 150A single-phase disconnects and one 60A loadcenter.
Galvanized Steel/Copper
Copper, Galvanized, PVC
Gas-Fired None No
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
Split Direct Expansion (Air
Source)
Single Duct Refrigerant Electric Mechanical None Entire Building
High Intensity Discharge (HID)
Comments: Building-mounted light fixtures are controlled by photocell.
LIGHTING
Main Disconnect Switch 120/208V, 3-Phase, 4 Wire Loadcenter Receptacles, GFCI, Switches
Sprinkler System Stand Pipe System Fire Suppression
PLUMBING
The cooling is provided by two 10 ton condensing units (a Carrier #38ARZ012, built 2002 and a Trane #TTA120300DL, built 9/2001) mounted at grade level on concrete pads. The air is circulated by a Carrier (#40RM024B511GC, 8000 CFM) air handling unit with two evaporater coils.
Comments:
Number of Deficiencies = 1
System Type
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
Water Distribution1.
Sanitary Distribution2. Number of Deficiencies = 1
Fixtures3.
Fuel Distribution4.
FIRE PROTECTION
ELECTRICAL SERVICES Number of Deficiencies = 6
Exterior Lighting1. Number of Deficiencies = 1
Page: 313 of 513
Building: 07-216 - DORMITORY
FIRE ALARM
Comments: The fire alarm panel is an ESL 1500.
Comments: Pay phones are provided for student use. The building is connected to the center LAN system for data communications.
Audible Alarm Control/Annunciator Panel Duct Smoke Detector Heat Detector Manual Pull Station Smoke Detector Visual Alarm
Connected to Main System Magnetic Door/Alarm None Local Cable Company
Telephone Security Public Address Television
Comments: Recorded footcandle levels include natural light contribution. Compact fluorescent fixtures are utilized in the corridors and lounge area. T12 -fluorescent light fixtures are also utilized throughout the building.
T8 - Fluorescent
T12 and T8 - Fluorescent
T8…