S05. IN110.pdf

PDF 1 MB Posted

Attached to
Renovate 3rd Floor Ambulatory Care for Specialty Care Clinic
Solicitation number
36C25025B0011_1Amend02
Issued by

About this file

This is an interior design finish plan drawing showing the third floor layout for a VA specialty care clinic renovation project. The drawing provides a detailed floor plan at 3/16" = 1'-0" scale showing exam rooms, offices, corridors, restrooms, utility spaces and other clinical areas with associated room numbers and finish specifications.

The plan indicates finish materials with codes like P-1 (paint), RB-1 (rubber base), LVT-1 (luxury vinyl tile), PT-1 (porcelain tile), and various other finishes for walls, floors and ceilings throughout the space. The drawing includes finish plan notes, keynotes, and a legend explaining the finish patterns and symbols used. Key spaces shown include multiple exam rooms, nurse stations, patient corridors, a dialysis training area, conference rooms, and support spaces like clean/soiled utility rooms and storage areas. The drawing is part of the construction documents for renovating the third floor ambulatory care area into a specialty care clinic at a VA facility.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FINISH MARK

ROOM FINISH TAG

Room Name

WAL-1

BAS-1

FLR-1 FLOOR

WALL

WALL BASE

* INDICATES MORE THAN 1 FINISH

HR-1 HANDRAIL

1. PREPARE SUBSTRATES IN ACCORDANCE WITH FINISH MANUFACTURER’S REQUIREMENTS AND

RECOMMENDATION FOR SUBSTRATE INDICATED AND AS REQUIRED FOR APPROPRIATE, COMPLETE

AND BLEMISH-FREE APPLICATION.

2. SEE INTERIOR ELEVATIONS FOR EXTENT OF WORK WHERE MORE THAN ONE FINISH OCCURS ON A

WALL.

3. CENTER FLOOR AND CEILING FINISHES AND PATTERNS WITHIN ROOM, EXCEPT AS INDICATED

OTHERWISE.

4. WHERE FLOOR FINISHES CHANGE AT COMMUNICATING ROOMS, PLACE TRANSITION UNDER

CENTER OF DOOR OR FINISHED OPENING.

5. PROVIDE FLAT PAINT FINISH ON PAINTED CEILINGS, SATIN FINISH ON GYPSUM BOARD PARTITIONS, SEMI GLOSS ON PRIMED METAL INCLUDING HM DOORS AND FRAMES, EXCEPT AS INDICATED

OTHERWISE.

6. EXISTING WALLS WITHIN SCOPE OF WORK TO BE PATCHED AND PAINTED, EXCEPT AS INDICATED

OTHERWISE.

7. FLOOR FINISHES TO EXTEND UNDER CASEWORK AND APPLIANCES.

8. CONTRACTOR TO VERIFY PROFILE OF FLOOR TRANSITIONS AT FLOORING EXISTING TO REMAIN.

9. IMPACT RESISTANT GYPSUM BOARD TO BE INSTALLED AT ALL CORRIDOR WALLS U.N.O.

11. REFER TO SHEET IN010 FOR FINISH SCHEDULE & SPECIFICATIONS

12. REFER TO SHEET IN010 FOR FINISH TRANSITION DETAILS AND LEGEND FOR TRANSITION TYPES

50 51 52 53 5453A

M

N

O

K

L

EXAM 2

3AC342

P-1 UNO

RB-1

LVT-1

EXAM 3

3AC341

P-1 UNO

RB-1

LVT-1

EXAM 10

3AC355

P-1 UNO

RB-1

LVT-1

EXAM 5

3AC350

P-1 UNO

RB-1

LVT-1

EXAM 4

3AC340

P-1 UNO

RB-1

LVT-1

EXAM 6

3AC354

P-1 UNO

RB-1

LVT-1

EXAM 7

3AC356

P-1 UNO

RB-1

LVT-1

EXAM 8

3AC358

P-1 UNO

RB-1

LVT-1

PATIENT RR

3AC353

PT-1/P-5

TS-1

PT-1

EXAM 9

3AC351

P-1 UNO

RB-1

LVT-1

EXAM 12

3AC359

P-1 UNO

RB-1

LVT-1

EXAM 11

3AC357

P-1 UNO

RB-1

LVT-1

LARGE EXAM 2

3AC349

P-1 UNO

RB-1

LVT-1

OFFICE - CARDIOLOGY

3AC369

P-1 UNO

RB-1

CPT-1

STAFF RR

3AC365

PT-1/P-5

TS-1

PT-1

P -3

G F

-1

P-2

P T

-1

LOBBY

3AC310

P-1 UNO

RB-1

PT-1*

P-3

PROJECT LIMIT LINE

PROJECT LIMIT LINE

158 158

CHECK IN

3AC322

P-1 UNO

RB-1

CPT-1

CHECK OUT

3AC336

P-1

RB-1

CPT-1

EKG EXAM

3AC346

P-1 UNO

RB-1

LVT-1

EXAM 1

3AC345

P-1 UNO

RB-1

LVT-1

PATIENT RR

3AC343

PT-1/P-1

TS-1

PT-1

DIALYSIS RR

3AC370A

PT-1/P-5

TS-1

PT-1

DIALYSIS TRAINING

3AC370

P-1 UNO

RB-1

LVT-1

LARGE EXAM 1 /ALT EKG

EXAM

3AC348

P-1 UNO

RB-1

LVT-1

SOILED UTILITY

3AC352

FRP-1/P-5

SV-1

SV-1

CLEAN SUPPLY

3AC368

FRP-1/P-5

RB-1

SV-1

STERILE SUPPLY

3AC374

FRP-1/P-5

SV-1

SV-1

MEDICATION

3AC372

P-1

SV-1

SV-1

BREAK ROOM

3AC367

P-1 UNO

RB-1

LVT-1

LARGE CONFERENCE

3AC361

P-1 UNO

RB-1

CPT-1

SMALL CONFERENCE

3AC362

P-1 UNO

RB-1

CPT-1

TEAMING

3AC363

P-1 UNO

RB-1

CPT-1

ELEC

3AC337

P-1 UNO

RB-1

SC-1

H/W ALCOVE

3AC321

P-1

RB-1

LVT-1

STRETCHER ALCOVE

3AC332

P-1

RB-1

LVT-1

NURSE STATION

3AC347

P-1

RB-1

LVT-1

NURSE STATION

3AC375

P-1

RB-1

LVT-1

NURSE STATION

3AC344

P-1

RB-1

LVT-1

PATIENT CORRIDOR

3AC339

P-1

RB-1

LVT-1

STAFF CORRIDOR

3AC364

P-1

RB-1

LVT-1

STAFF RR

3AC366

PT-1/P-5

TS-1

PT-1

OIT ROOM

3AC335

PATIENT CORRIDOR

3AC333

P-1

RB-1

LVT-1

CORRIDOR

3AC332

P-1

RB-1

LVT-1

PATIENT CORRIDOR

3AC320

P-1

RB-1

LVT-1

PATIENT CORRIDOR

3AC360

P-1 UNO

RB-1

LVT-1

PATIENT CORRIDOR

3AC376

P-1

RB-1

LVT-1

PATIENT CORRIDOR

3AC338

P-1 UNO

RB-1

LVT-1

SCHEDULING ALCOVE

3AC332A

P-1 UNO

RB-1

LVT-1

V

IF

V

IF

ALIGN

EXST PT-1

EXST

PT-1

PT-2

PT-2

CG-1A

CG-2

PLAM-2

PT-1

CG-1B

CG-1B

CG-1B

CG-1A

CG-1A

CG-2

CG-1A

CG-1A

CG-1A

CG-1B

CG-2

CG-2

CG-1A

CG-2

CG-1A

CG-2

CG-1A

CG-1B

CG-1B

CG-1B

CG-1B

CG-1B

CG-1B

CG-1A

PT-2

CG-1A

CG-1A

CG-2

CG-1A

CG-1A

CG-1A

CG-1A

CG-1A

CG-1A CG-1A

CG-1A

CG-1A

CG-1A

P

LA

M -2

P

LA

M -2

JANITORIAL -

HAZARDOUS

ROOM

3AC334

STAIR B

3S3

CORRIDOR

3AC281

EYE CLINIC

WAITING

3AC210

CG-2

CG-2 CG-2

CG-1A

G F

-1

CG-1A

CG-1A

CG-1A

CG-1A

CG-1A

CG-1A CG-1A

OIT ROOM

3AC371

ELECTRICAL

ROOM

3AC373

STAIR A

3S1

P -1

ALIGN

P -3

P -3

P -3 P

-3 P

-3

P -3

P -3

P -3

P -3

P -3

P -3

P-3

P -2

P -3

P-2

P-2

P-1 P-1ACR-1

6'-4"

P -3

P -3

CG-1A

CG-1A

CG-1A

CG-1A

PT-2

PT-1

ALIGN

P -3

P -3

P -3

P -3

9"

CG-1A

CG-2

CG-2

STORAGE

3AC323

SC-1

LVT-1

PT-1

SC-1

SEALED

CONCRETE

OUT OF

SCOPE

PT-2

CPT-1

SV-1

FLOOR PATTERNS:

EXISTING TO

REMAIN

Location

Issue Date o n e e ig h th i n c h o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t

REVISIONS: DATE:

Project Number

Building Number

Drawing Number

Project Title

Checked Drawn

Drawing Title

Approved:

A

4 3 2 1678910

5 4 3 2 1678910

B

C

D

E

F

G

A

B

C

D

E

F

G

Phase

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

STAMP

PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE

WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE

PROFESSIONAL ENGINEER.

ARCHITECT / ENGINEERS OF RECORD:CONSULTANT:

Mechanical, Electrical, Plumbing & Technology Engineers:

IMEG Corp.

672 E. Royalton Rd.

Broadview Heights, OH 44147 Phone: 440-546-9696 Cost Estimating:

OCMI, Inc.

1722 Routh Street, Suite 900 Dallas, TX 75201 Phone: 469-431-0571

A/E:

L2e-Oculus JV 20 South Sarah Street St. Louis, MO 63108 Phone: 314-730-2779 Firm POC: Elaine Lewis

IN110

541-23-101RENOVATE 3RD FLOOR AMB CARE FOR

SPECIALTY CARE CLINIC

LOUIS STOKES CLEVELAND VAMC

October 1, 2024 BB EM

INTERIOR DESIGN THIRD FLOOR FINISH

PLAN

FINAL CONSTRUCTION DOCUMENT

SUBMISSION

LEGEND

FINISH PLAN NOTES

0' 4' 8' 16' 32'

3/16" = 1'-0"G10 INTERIOR DESIGN THIRD FLOOR FINISH PLAN

KEYNOTES

158 GC DETERMINE REQUIRED HEIGHT AND PROFILE OF FINISH TRANSITIONS IN AREAS WHERE NEW

FINISHES MEET EXISTING FINISHES.

PLAN

NORTH

ACTUAL

NORTH

1 ADDENDA 1 1/21/2024

Sheets
IN110 - INTERIOR DESIGN THIRD FLOOR FINISH PLAN

File details come from the government source that posted it. Updated .