S05. Door Hardware 08 71 00-22.pdf
PDF 244 KB Posted
- Solicitation number
- 36C25025B0011_1Amend02
About this file
This is a door hardware specifications document from section 08 71 00-22 for the renovation of the 3rd Floor Ambulatory Care for Specialty Care Clinic project (Task Order 36C25023C0022, Project 541-23-101). The document details specific hardware requirements for different door types, focusing on two main configurations: HW-12H and HW-SH-3.
The specifications include detailed hardware requirements for non-rated automatic door operator (ADO) pairs and rated/non-rated access-controlled doors. For HW-12H (door 320), requirements include continuous transfer hinges with integral guard channels, electronic exit devices, power supplies, kick plates, wall stops, and self-adhesive seals. For HW-SH-3 (doors 3S1, 322, 323, 325, 333, 336, 338, 369, 372, 376), specifications call for transfer hinges, electrified locks, power supplies, closers, wall stops, and alarm contacts. The document also indicates that certain components like card readers and auto door operators are to be provided by different divisions (Division 28 and Section 08 71 13.11 respectively).
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Renovate 3rd Floor Amb Care for Specialty Care Clinic Final CD Submission
Task Order 36C25023C0022
Project: 541-23-101 1-9-2024
05-01-22
DOOR HARDWARE
08 71 00-22
2 Closers C02011/C02021
2 Kick Plates J102 (@ STORAGE ROOMS ONLY)
1 Set Self-Adhesive Seals R0Y154
HW-12H (320)
Each (ADO) Pair to Have: NON-RATED
2 Continuous Transfer Hinges X INTEGRAL HINGE GUARD CHANNEL
X ADJUSTA-SCREWS X 8-THRUWIRE
TRANSFER X IN-HINGE ACCESS PANEL
1 Elec. Exit Device TYPE 7 or 8 F01 (E04)
1 Elec. Exit Device TYPE 7 or 8 F08 LEVER (E04)
1 Key Cylinder TYPE AS REQUIRED
1 Power Supply BY EXIT DEVICE MFGR. FOR E04 FUNCTION
1 Set Meeting Stile Astragals R0Y834
4 Kick Plates J102
2 Wall Stop L02101 CONVEX
2 Auto Door Bottoms R0Y346 – HEAVY DUTY
2 Sets Self-Adhesive Seals R0Y154
POWER TRANSFERS SHARED BY ELECTRIC PANIC AND RE-ACTIVATION SENSOR WIRING
(RE-ACTIVATION SENSORS PROVIDED BY SECTION 08 71 13.11 AND AUTO DOOR
OPERATORS AND CONTROLS BY SECTION 08 71 13.11)
HW-SH-3 (3S1, 322, 323, 325, 333 w/ADO, 336, 338, 369, 372, 376)
Each (AC, EL, REX, DPS) Door to Have: RATED/NON-RATED
1 Transfer Hinge 4-WIRE TYPE AS REQUIRED
1 Electrified Lock F07 (E01-REX, E06) 24VDC
1 Power Supply REGULATED, FILTERED, 24VDC, AMPERAGE
AS REQUIRED
1 Closer (not at 333) C02011/C02021
1 Wall Stop L02101 CONVEX
2 Sets Self-Adhesive Seals R0Y154
1 Alarm Contact
120VAC POWER, CONDUIT, AND WIRING BY DIVISION 26.
CARD READER BY DIVISION 28.
AUTO DOOR OPERATORS AND CONTROLS (ON DOORS SPECIFIED) BY SECTION
08 71 13.11