This is a demolition reflected ceiling plan drawing (AD210) for the renovation of the 3rd floor Ambulatory Care area at the Louis Stokes Cleveland VA Medical Center Specialty Care Clinic. The drawing shows detailed demolition plans for existing lighting fixtures, including 2x4 and 2x2 fixtures, linear fixtures, and 6" round fixtures.
The plan indicates areas of complete interior demolition, existing construction to remain, and construction to be demolished. Key specifications include salvaging wood-look metal panel ceiling tiles for reinstallation in the new design, coordinating ceiling and roof penetration demolition with mechanical drawings, and demolishing gypsum soffits and framing. General notes require patching of walls damaged during demolition, preservation of existing window treatments, and replacement of ceiling tiles removed during construction in areas outside rated construction barriers. The drawing is dated October 1, 2024, and is part of the final construction document submission for VA project number 541-23-101.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DEMO EXISTING 2X4 LIGHT FIXTURE
DEMO EXISTING 2X2 LIGHT FIXTURE
DEMO EXISTING LINEAR LIGHT
FIXTURE
DEMO EXISTING 6" ROUND
LIGHTFIXTURE
DENOTES AREA OF RENOVATION WHICH INCLUDES COMPLETE
DEMOLITION OF ALL EXISTING INTERIOR CONSTRUCTION
EXISTING CONSTRUCTION TO
REMAIN
EXISTING CONSTRUCTION TO
BE DEMOLISHED
50 51 52 53 5453A
M
N
O
K
L
PROJECT LIMIT LINE
OIT ROOM
3AC371
ELECTRICAL
ROOM
3AC373
STAIR A
3S1
CORRIDOR
3AC281
JANITORIAL -
HAZARDOUS
ROOM
3AC334
OIT ROOM
3AC335
PROJECT LIMIT LINE
LOBBY
3AC310
AISLE
3AC354
WAITING AREA
3AC313
CONFERENCE
3AC344A
OFFICE 17
3AC342
OFFICE 16
3AC340
OFFICE 19
3AC349
OFFICE 20
3AC350
CORRIDOR
3AC345
OFFICE 18
3AC348
FILE ROOM
3AC347WORK ROOM
3AC346
OFFICE 15
3AC338
OFFICE 13
3AC336
OFFICE 12
3AC335
OFFICE 9
3AC332
OFFICE 7
3AC330
RESIDENT
3AC328A
OFFICE 5
3AC327
OFFICE 4
3AC326
OFFICE 3
3AC325
OFFICE 2
3AC324
OFFICE 1
3AC323
CORRIDOR
3AC314
OFFICE 14
3AC337
OFFICE 11
3AC334
BREAK ROOM
3AC333
WOMEN
3AC341
MEN
3AC339
OFFICE 8
3AC331
OFFICE 6
3AC329
52 53 5453A
N
O
2' -6
TREATMENT AREA
4AC355
TREATMENT AREA
4AC354
TREATMENT AREA
4AC353
SPD STERILE STORAGE
4AC347
TREATMENT AREA
4AC346
TREATMENT AREA
4AC357
HAC
4AC356
TOILET STAFF
4AC380 LOCKERS/LOUNGE
4AC379
CORRIDOR
4AC370
OFFICE
4AC378
CORRIDOR
4AC350
Location
Issue Date o n e e ig h th i n c h o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t
REVISIONS: DATE:
Project Number
Building Number
Drawing Number
Project Title
Checked Drawn
Drawing Title
Approved:
A
4 3 2 1678910
5 4 3 2 1678910
B
C
D
E
F
G
A
B
C
D
E
F
G
Phase
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
STAMP
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
ARCHITECT / ENGINEERS OF RECORD:CONSULTANT:
Mechanical, Electrical, Plumbing & Technology Engineers:
IMEG Corp.
672 E. Royalton Rd.
Broadview Heights, OH 44147 Phone: 440-546-9696 Cost Estimating:
OCMI, Inc.
1722 Routh Street, Suite 900 Dallas, TX 75201 Phone: 469-431-0571
A/E:
L2e-Oculus JV 20 South Sarah Street St. Louis, MO 63108 Phone: 314-730-2779 Firm POC: Elaine Lewis
AD210
541-23-101RENOVATE 3RD FLOOR AMB CARE FOR
SPECIALTY CARE CLINIC
LOUIS STOKES CLEVELAND VAMC
October 1, 2024 BB CM
DEMOLITION REFLECTED CEILING PLAN FINAL CONSTRUCTION DOCUMENT
SUBMISSION
GENERAL NOTES
LEGEND
0' 4' 8' 16' 32'
3/16" = 1'-0"G10 DEMOLTION REFLECTED CEILING PLAN
KEYNOTES
14 COORDINATE DEMOLITION OF CEILING AND ROOF PENETRATION WITH MECH. DRAWINGS.
15 DEMO GYP SOFFIT AND FRAMING.
17 SALVAGE ALL WOOD-LOOK METAL PANEL CEILING TILES. USE FOR REINSTALLATION IN NEW DESIGN
AS APPLICABLE. PROVIDE REMAINING WOOD-LOOK METAL PANEL CEILING TILES TO VA.
PLAN
NORTH
ACTUAL
NORTH
3/32" = 1'-0"D10 DEMOLITION FOURTH FLOOR CEILING PLAN
A. PATCH EXISTING WALL THAT HAS BEEN DAMAGED DUE TO REMOVAL OR INSTALLATION OF ANY ELECTRICAL DEVICES, PLUMBING OR MECHANICAL DEVICES TO PAINT READY CONDITIONS. PATCHING INCLUDES, BUT NOT LIMITED TO SKIMMING PATCHING OR INFILLING OF WALL FOR NEW SURFACE. THE PATCH SHALL BE COMPLETED IN A MANNER TO PREVENT "FLASHING" EFFECT WHEN PRIMED AND
PAINTED.
INCLUDING:
• PARTITIONS
• CEILINGS
• FINISHES
• LIGHTING
• CASEWORK
• PLUMBING FIXTURES
• DOORS, FRAMES AND ALL ASSOCIATED HARDWARE
• FILLING AND REPAIRING VOIDS AND RECESSIONS IN FLOOR
SLABS DUE TO DEMOLITION OF CERAMIC TILE, EQUIPMENT PARTITIONS, ETC.
B. ALL WALLS, PARTITIONS, DOORS, WINDOWS AND ASSOCIATED ELEMENTS INDICATED AS HALF TONE SHADE ARE EXISTING ELEMENTS
TO REMAIN IN PLACE.
C. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR DISCONNECTION AND CAPPING OF BUILDING UTILITIES
D. PROVIDE WALL AND PARTITION BLOCKING, AS REQUIRED, AND ALL REQUIRED UTILITY ROUGH-INS .
E. PATCH AND REPAIR ALL AREAS/LOCATIONS OF WALLS AND PARTITIONS TO REMAIN IN PLACE THAT WERE DAMAGED BY REMOVAL OF ITEMS DURING DEMOLITION WORK. (PATCH BACK WITH IDENTICAL MATERIALS, UNLESS OTHERWISE NOTED.)
F. PATCH EXISTING WALL THAT HAS BEEN DAMAGED DUE TO REMOVAL OF ANY EXISTING WALL HUNG ITEMS INCLUDING, BUT NOT LIMITED TO CABINETS, EQUIPMENT, FIXTURES AND MISCELLANEOUS ACCESSORIES TO PAINT READY CONDITIONS. PATCHING INCLUDES, BUT NOT LIMITED TO SKIMMING PATCHING OR INFILLINGOF WALL FOR NEW SURFACE. THE PATCH SHALL BE COMPLETED IN A MANNER TO
PREVENT "FLASHING" EFFECT WHEN PRIMED AND PAINTED.
G. OWNER RESERVES THE RIGHT OF FIRST REFUSAL FOR ANY ITEMS REMOVED DURING DEMOLITION.
H. EXISTING WINDOW TREATMENTS IN AFFECTED AREAS TO BE REMOVED, PRESERVED, CLEANED FOR REINSTALLATION.
J. REPLACE ANY CEILING TILES REMOVED FOR CONSTRUCTION ACTIVITIES AT THE END OF EACH SHIFT IN AREAS OUTSIDE OF THE
RATED CONSTRUCTION BARRIER.
VHACLEClarR1 Callout 8'-1"
VHACLEClarR1 Callout 8'-0 1/4"
VHACLEClarR1 Callout 7'-11 1/4"
VHACLEClarR1 Callout 8'-1"
VHACLEClarR1 Callout 8'-1"
VHACLEClarR1 Callout 7'-11 1/4"
VHACLEClarR1 Callout 8'-0 1/4"
VHACLEClarR1 Rectangle
VHACLEClarR1 Callout 7'-11 1/4"
VHACLEClarR1 Callout 8'-0 1/4"
VHACLEClarR1 Callout 7'-11 1/4"
VHACLEClarR1 Callout 8'-0 1/4"
VHACLEClarR1 Callout 7'-11 1/4"
VHACLEClarR1 Callout 8'-2"
| Sheets |
| AD110 - DEMOLITION THIRD FLOOR PLAN |
| AD210 - DEMOLITION REFLECTED CEILING PLAN |
| AE010 - WALL & PARTITION ASSEMBLIES |
| AE011 - TYPICAL PARTITION DETAILS |
| AE012 - TYPICAL MOUNTING DETAILS |
| AE020 - DOOR SCHEDULE, DOOR & FRAME TYPES & ELEVATIONS |
| AE021 - DOOR & FRAME DETAILS |
| AE030 - CASEWORK DETAILS |
| AE040 - CEILING DETAILS |
| AE110 - ARCHITECTURAL THIRD FLOOR PLAN |
| AE111 - ARCHITECTURAL FOURTH FLOOR PLAN, RCP & ROOF PLAN |
| AE150 - EQUIPMENT THIRD FLOOR PLAN |
| AE151 - ENLARGED EQUIPMENT PLANS |
| AE210 - ARCHITECTURAL REFLECTED CEILING PLAN |
| AE400 - INTERIOR ELEVATIONS |
| AE401 - INTERIOR ELEVATIONS |
| AE402 - INTERIOR ELEVATIONS |
| AE403 - INTERIOR ELEVATIONS |
| AE404 - INTERIOR ELEVATIONS |
| AE405 - INTERIOR ELEVATIONS |
| AE600 - INTERIOR DETAILS |
| GI000 - COVER SHEET |
| GI001 - DRAWING INDEX, ABBREVIATIONS, GENERAL NOTES AND SYMBOLS |
| GI100 - LIFE SAFETY ANALYSIS |
| GI110 - LIFE SAFETY PLAN - PROPOSED |
| GI111 - LIFE SAFETY PLAN - DURING CONSTRUCTION |
| GI120 - PHASING PLAN |
| GI121 - PHASING PLAN - PLUMBING ACCESS |
| GI122 - PHASING PLAN - TILE RECONSTRUCTION |
| GI123 - PHASING PLAN - TILE RECONSTRUCTION |
| IG010 - SIGNAGE TYPES |
| IG011 - SIGNAGE TYPES |
| IG400 - ENLARGED INTERIOR SIGNAGE PLAN AND SCHEDULE |
| IN010 - FINISH LEGEND AND DETAILS |
| IN110 - INTERIOR DESIGN THIRD FLOOR FINISH PLAN |
File details come from the government source that posted it. Updated .