FD

M

L

K

J

H

G

7 8 9 10

11 12

3004 3005

3100.1

OFFICE

CHIEF

OFM1

SECRETARY

WAITING

OFA1

DEPUTY

CHIEF

OFA1

HRDW

TEAM

LEADER

OFA1

RESOURCE

MANAGER

OFA1

CONFERENCE

ROOM

CRA02

REFERENCE

LIBRARY

NETWORK

MANAGER

OFA1

PROJECT

WORK

AREA

OFA03

STAFF

LOUNGE

SL001

VISTA

SYSTEM

ADMIN

OFA03

VISTA

SYSTEM

ADMIN

OFA03

IT SPEC.

OFA03

INTERN

OFA03

IT SPEC.

OFA03

APP

SPEC.

OFA03

IT SPEC.

OFA03

IT SPEC.

OFA03

IT SPEC.

OFA03

IT SPEC.

OFA03

IT SPEC.

OFA03

IT SPEC.

OFA03

IT SPEC.

OFA03

IT SPEC.

OFA03

IT SPEC.

OFA03

NETWORK

ADMIN

OFA03

APP

COOR.

OFA03

EXIST.

STAIR #1

MALE

TOILET

TLTU1

FEMALE

TOILET

TLTU1

NETWORK

ADMIN

OFD01

IT SPEC

OFA03

IT SPEC

OFA03

IT SPEC

OFA03

HELP

DESK

SPEC.

OFA03

HELP

DESK

SPEC.

OFA03

HELP

DESK

SPEC.

OFA03

STAGING

INVENTORY

SUBWAIT

WRC01

SUPERVISOR

INVENTORY

OFD01

STAGING/INVENTORY

CONTROL

APP

SPEC.

OFA03

APP

SPEC.

OFA03

APP

SPEC.

OFA03

INTERN

OFA03

IT SPEC

OFA03

OUTGOING

INVENTORY

CONTROL

EXIST.ELEC

CLOSET

EXIST.

COMM

ROOM

JANITOR

3107.1

JANC01

JANITOR

3107.2

JANC01

SHELL

SPACE

FUTURE

COMPUTER

ROOM

(N.I.C.)

EXIST.

STAIR

#2A

EXIST.

STAIR #2

EXIST.

ELEVATOR

#2

EXIST.

ELEVATOR

#1

UTILITIES

SHAFT

#1

EXIST.

ELEVATOR

#4

UTILITIES

SHAFT

#2

EXIST.

SERVICE

ELEVATOR

EXIST.

SERVICE

ELEVATOR

WORKSHOP

FUTURE

OFFICE

SPACE

IT SPEC

OFA03

HELP

DESK

SUP.

OAD01

HELP

SUBWAIT

WRC01

EXIST.

ELEC.

CLOSET

EXIST.

CHASE

COMM

ROOM

EXIST.

CHASE

AS2-302R-P2

B5

SERVICE

LOBBY

AS2-302R-P2

A1

AS2-302R-P2

B1

INTERN

OFA03

IT SPEC.

OFA03

IT SPEC

OFA03

CORRIDOR

VISTA

IMAG

(PACS)

OFA03

VISTA

SYSTEM

ADMIN

OFA03

APP

COOR.

OFA03

VISTA

IMAG

(PACS)

OFA03

APP

SPEC

OFA03

APP

SPEC

OFA03

CORRIDOR

AS2-302R-P2

C1

A1

A1

A1

A1 B1 A1 A1

A1

A1

C1

C1

A1

B1

C1

C1

B1

C1

K1

A1

K1

B1

B1

K1

B1

A1

A1

A1

A1

A1A1

A1

R1

R1

R1

R4 A1

R1

R1

R1 R1

R1 R4

R1

R4

R1

B1

A1 B1 A1

A1

R4 R4 R4

R4

R1K1

R1

R1

R1

K1

R1

R1

R1

R1

R1

R1

R1

R1

K1

R1

K1

R1

R1

R1

R1

R1

R1

R1

R1 R1

R1

R1 R1

R1

R1

K1

R1

R1

R1

R1

R1

R1

R1

K1

R1

R1

R1

R1

R1

R1

R1

R1

R1

R1 R1

R1

R1

K1

R1

R1

K1

R1

K1

R1

K1 K1

R1

K1

R1 R1

R1

R1

R1

R1

R1 R1

R1

R1 R1

R1

R1

A1 A1

A1

A1

A1

A1

A1C1

R4

K1

A1

A1

A1

A1

C2

A1

A1

R1

R1

K1

A1

A1

A1 A1

A1

B1 R3 R3

D1

A1

R1

C1

C2

R1

SIGNAL

AS2-302R-P2

C4

B1

B1

C1

B1

A1

B1

A1

CG-2

WP-1

CG-1

CG-1

WP-1

CG-1

CG-1

WP-1

WP-1

AS2-113R-P2

AS2-113R-P2

AS9-111R-P2

6 6

K1

1'-0"

5'-0"

CLEAR

NEW

UTILITIES

SHAFT

#3

EE1

EE1

ALIGN

C L

E A

R

A L

I G

N

6'-0"

CLEAR

C1

7'-0"

EQ EQ

C L

E A

R

6'-0"

6'-0"

ALIGN

A L

I G

N

ALIGN

ALIGN

5'-0"

6'-0"

CLEAR

4"

A1

A1

R4

3 3 3 3

114'-5"

6'-10"

3 B1

B1

1'-6"

EE

A L

I G

N

ALIGN NEW

SHAFT WALL

TO CENTER

OF COLUMN

CG-1

CG-1

CG-1

WG-2WG-2

WG-2

CG-1CG-1

CG-1

CG-1

CG-1

WG-2

4"

12.5

EE1

CG-1

CG-1

CG-1

CG-1

CG-1

CG-1

CG-1

CG-1

CG-1

CG-1

CG-1

CG-1

EXISTING

CORRIDOR

TO

COMP/SERVER

ROOM

4"

4"

C2

C2

B1

B1

C2

1'-6"

COMM

ROOM

13'-10"

BUILD NEW

PARTITION AGAINST

EXISTING STRUCTURE

ALIGN

13'-7" 22'-9"

8'-0" 8'-0"

5'-7" 8'-0" 8'-0" 6'-11 1/2"

HR-1 (AS LABELED)

HR-2 (AS LABELED)

CG-1 (AS LABELED)

CG-2 (AS LABELED)

CG-3 (AS LABELED)

WG-1 (AS LABELED)

WG-2 (AS LABELED)

CHR-1 (AS LABELED)

WP-1 (AS LABELED)

WALL PROTECTION LEGEND

HANDRAIL 1

HANDRAIL 2

CORNER GUARD 1

CORNER GUARD 2

CORNER GUARD 3

WALL GUARD 1

WALL GUARD 2

CHAIR RAIL 1

SHEET WALL

PROTECTION 1

72" AFF TYPICAL

o n e e i g h t h i n c o e f o o t o n e q u a r t e r i n e f o o t t h r e e e i g h t i e f o o t o n e h a l f i n e f o o t t h r e e q u a r t e r s i n e f o o t o n e i n e f o o t o n e a n d o n e h a l f i n e f o o t t h r e e i n c h e s e f o o t

CONSULTANTS: ARCHITECTS/ENGINEERS Office of Construction and Facilities Management

Department of

Veterans Affairs

BUILDING PARTIALLY SPRINKLERED (RENOVATED SPACES/

NEW PENTHOUSES IN THIS SCOPE OF WORK 100% SPRINKLERED )

BID SET 06/12/2015

GAUTIER de TORRES ARQUITECTOS Apartado 19357, San Juan, Puerto Rico 00910-1357

DEGENKOLB ENGINEERS

235 MONTGOMERY ST, SAN FRANCISCO, CA 94104

SAQ ENVIROMENTAL ENGINEERS, INC

PO.BOX 155, MANATI, PR 00674

LASALLE ENGINEERING, LLC

1000 YORK ROAD WILLOW GROVE, PA 19090

M.A + ASSOCIATES, LLC

8655 CHERRY LANE, LAUREL, MD 20707

CT + ASSOCIATES, LLC

86 THOMAS LEIGHTON BLVD, CUMBERLAND, RHODE ISLAND 02864

KEY PLAN

BID SET 06/12/2015

N:

\14

2-

VA

CH

S

SE

IS

MI

C

TA

SK

CD

\G

DT

\LO

CA

L F

ILE

S\

JO

SE

MI

LIO

\17

A-

GD

TV

AS

J-C

EN

TR

AL

_jo se mi lio .fe rre r.r vt 3/1

8/2

6 1 2:0

7:1 6 P

M

AS2-112R-P2

ENLARGED ARCHITECTURAL PLAN-THIRD

FLOOR

ED MR06/12/2015

672-085APHASE 3 BUILDING ONE-SEISMIC

CORRECTIONS AND RENOVATIONS

VA Caribbean Healthcare System 10 Casia Street, San Juan, PR 00921-3201

1101 King Street Suite 400, Alexandria, VA 22314

1/8" = 1'-0"

ENLARGED ARCHITECTURAL PLAN-THIRD FLOOR-P2

GENERAL SHEET NOTES

1 FOR GENERAL NOTES, SEE SHEETS GN-001 & GN-002.

2 FOR DEMOLITION NOTES, SEE AD1-100R SERIES.

3 FOR SYMBOLS LEGEND AND ABBREVIATIONS, SEE SHEET GN-001.

4 RENOVATION WORK AT FIRST FLOOR SHALL BE BROKEN OUT INTO TWO (2)

DIFFERENT PHASES OR WORK (P1 AND P2).

5 FOR PARTITION TYPES, SEE AS8-300R SERIES.

6 FOR INTERIOR ALUMINUM AND GLASS DOORS AND SIDELIGHTS DETAILS, SEE

AS8-100R SERIES.

7 FOR ENLARGED TOILET ROOM PLANS, SEE AS2-300R SERIES.

8 FOR ENLARGED EQUIPMENT PLANS, SEE AS9-100R SERIES.

9 SEE FLOOR PLANS, ELEVATIONS, AND CEILING PLANS FOR LOCATIONS OF

EXPANSION JOINT ASSEMBLIES. SEE SPECIFICATION SECTION 07 95 13 FOR

PARAMETERS REGARDING THESE JOINTS.

10 ALL NEW STURCTURAL MEMBERS TO HAVE NEW APPLIED FIRE-PROOFING.

11 THE CONTRACTOR SHALL SEISMICALLY BRACE ALL EXISTING AND NEW

NON-STRUCTURAL ELEMENTS WITHIN RENOVATION "CONSTRUCTION LIMIT" AS

REQUIRED BY CODE. REFER TO SPCIFICATION SECTION 130541 (SEISMIC

RESTRAINT REQUIREMENTS FOR NON-STRUCTURAL COMPONENTS) FOR

ADDITIONAL INFORMATION.

12 FOR STRUCTURAL SUPPORT AT WALL MOUNTED ITEMS SEE AS7-400R SERIES.

13 WHERE PARTITION TYPE C1 IS USED ON THE PERIMETER OF SMOKE

COMPARTMENTS (REFER TO LIFE SAFETY DRAWINGS) IT SHALL BE BUILT TO

SATISFY THE REQUIREMENTS OF A SMOKE BARRIER.

14 FOLLOWING CONSTRUCTION, REMOVE TEMPORATY PARTITIONS (E1T, E2T, E3T)

AROUND CONSTRUCTION AREA. REPAIR FINISHES IN FLOOR, WALLS AND

CEILING.

15 EXISTING COLUMNS ARE CURRENTLY ENCASED IN CONCRETE. RENOVATION

SCOPE OF WORK REQUIRES ALL EXISTING COLUMNS TO BE FINISHED WITH A

TYPE "R" PARTITION UNLESS OTHERWISE NOTED. REFER TO WALL TAGS ON

ENLARGED PLANS. SEE SHEET AS8-301R FOR PARTITION TYPES AND SCHEDULE.

16 PROVIDE FIRE DAMPER IF EXISTING DUCTS HAVE OPENINGS INTO THE

PASSAGEWAY (CORRIDOR).

KEYNOTES P2

2 THE CONTRACTOR SHALL FURNISH AND INSTALL NEW FLOOR DRAINS AT THE

EXISTING CONCRETE/STEEL DECK SLAB AS SHOWN AND SLOPE THE FLOOR

TOWARD THE FLOOR DRAIN. THE FLOOR DRAIN SHALL BE THE LOW POINT OF

THE FLOOR. PROVIDE A METAL SUPPORT PLATE WHEN DRAIN IS INSTALLED IN

AN EXISTING FLOOR; CAULK AROUND DRAIN PRIOR TO RE-GROUTING. FLOOR

DRAIN LOCATION SHOWN FOR REFERENCE ONLY. GENERAL CONTRACTOR SHALL

COORDINATE FINAL FLOOR DRAIN LOCATION PER VA GUIDELINES AND PLUMBING

PLANS.

3 WHERE NEW PARTITION C1 AND K1 MEET EXISTING WALL, NEW PARTITION SHALL

ALIGN OR CONTINUE FROM EXISTING WALL AND INTEGRITY OF MOST

RESTRICTIVE FIRE OR SMOKE RATING SHALL BE PRESERVED THROUGHOUT.

4 RELOCATE DOORS THAT WERE REMOVED AND SALVAGED DURING PHASE 1

TEMPORARY CONSTRUCTION. REFURBISH TO MATCH EXISTING. TO BE APPROVED

BY RESIDENT PROJECT ARCHITECT

5 INSTALL NEW PARTITION IN ORDER TO ENCLOSE EXISTING SPACE CONSISTENT

WITH ORIGINAL LAYOUT. NEW PARTITION SHALL BE FURNISHED AND FINISHED TO

MATCH EXISTING. TO BE APPROVED BY RESIDENT ENGINEER.

6 PLUMBING CHASE. GENERAL CONTRACTOR TO COORDINATE WITH PLUMBING

PLANS.

7 MECHANICAL CHASE. GENERAL CONTRACTOR TO COORDINATE WITH

MECHANICAL PLANS.

8 INSTALL SHAFT WALL AFTER TEMPORARY HYDRAULIC ELEVATOR REMOVAL IS

COMPLETED.

9 SINKS SHOWN FOR REFERENCE ONLY. TO BE PURCHASED AND INSTALLED BY

VCS.

WALL PROTECTION SHEET NOTES

1 SEE SHEET AS7-402R FOR TYPICAL WALL PROTECTION DETAILS.

2 CRASH RAIL, HANDRAIL, AND CHAIR RAIL TO START AND STOP 3" FROM CORNERS,

UNLESS OTHERWISE NOTED.

3 ALL OUTSIDE CORNERS TO RECEIVE CORNER GUARD, UNLESS OTHERWISE

NOTED.

4 ALL WALL PROTECTION EDGES TO RECEIVE CAULK TO ADJACENT SURFACES.

5 HANDRAIL TO STOP 2" FROM FIRE EXTINGUISHER CABINETS (FEC).

6 EXTEND ALL SHEET WALL PROTECTION TO ALL INSIDE AND OUTSIDE CORNERS IN

ENCLOSED ROOMS AND ALCOVES.

7 TYPICAL HEIGHT OF ALL WALL GUARDS TO BE 12" AFF ON CENTER.

8 TYPICAL HEIGHT OF ALL CHAIR RAILS AND HANDRAILS TO BE 32" AFF.

9 TYPICAL HEIGHT OF SHEET WALL PROTECTION TO BE 72".

NO REVISIONS DATE

SUBMITTAL 08 71 00-01 02/17/2017

RFI 0186

WALSH PUERTO RICO

RECEIVED

FEB 27 2017

RFI 0059

M

L

K

J

H

G

7 8 9 10

11 12

3004 3005

.1

.1

3100.1

.4

.2

.2

.1 31

.2

.3

.3

.5

OFFICE

CHIEF

OFM1

SECRETARY

WAITING

OFA1

DEPUTY

CHIEF

OFA1

HRDW

TEAM

LEADER

OFA1

RESOURCE

MANAGER

OFA1

CONFERENCE

ROOM

CRA02

REFERENCE

LIBRARY

NETWORK

MANAGER

OFA1

PROJECT

WORK

AREA

OFA03

STAFF

LOUNGE

SL001

VISTA

SYSTEM

ADMIN

OFA03

VISTA

SYSTEM

ADMIN

OFA03

IT SPEC.

OFA03 INTERN

OFA03

IT SPEC.

OFA03

APP

SPEC.

OFA03

IT SPEC.

OFA03

IT SPEC.

OFA03

IT SPEC.

OFA03

IT SPEC.

OFA03 IT SPEC.

OFA03

IT SPEC.

OFA03

IT SPEC.

OFA03

IT SPEC.

OFA03

IT SPEC.

OFA03

NETWORK

ADMIN

OFA03

APP

COOR.

OFA03

EXIST.

STAIR #1

MALE

TOILET

TLTU1

FEMALE

TOILET

TLTU1

NETWORK

ADMIN

OFD01

IT SPEC

OFA03

IT SPEC

OFA03

IT SPEC

OFA03

HELP

DESK

SPEC.

OFA03

HELP

DESK

SPEC.

OFA03

HELP

DESK

SPEC.

OFA03

STAGING

INVENTORY

SUBWAIT

WRC01

SUPERVISOR

INVENTORY

OFD01 STAGING/INVENTORY

CONTROL

APP

SPEC.

OFA03

APP

SPEC.

OFA03

APP

SPEC.

OFA03

INTERN

OFA03

IT SPEC

OFA03

OUTGOING

INVENTORY

CONTROL

EXIST.ELEC

CLOSET

EXIST.

COMM

ROOM

JANITOR

3107.1

JANC01 JANITOR

3107.2

JANC01

SHELL

SPACE

FUTURE

COMPUTER

ROOM

(N.I.C.)

EXIST.

STAIR

#2A

EXIST.

STAIR #2

EXIST.

ELEVATOR

#2

EXIST.

ELEVATOR

#1

UTILITIES

SHAFT

#1

EXIST.

ELEVATOR

#4

UTILITIES

SHAFT

#2

EXIST.

SERVICE

ELEVATOR

EXIST.

SERVICE

ELEVATOR

WORKSHOP

FUTURE

OFFICE

SPACE

IT SPEC

OFA03

HELP

DESK

SUP.

OAD01

HELP

SUBWAIT

WRC01

EXIST.

ELEC.

CLOSET

EXIST.

CHASE

COMM

ROOM

EXIST.

CHASE

AS2-302R-P2

B5

SERVICE

LOBBY

AS2-302R-P2

A1

AS2-302R-P2

B1

INTERN

OFA03

IT SPEC.

OFA03

IT SPEC

OFA03

CORRIDOR

VISTA

IMAG

(PACS)

OFA03

VISTA

SYSTEM

ADMIN

OFA03

APP

COOR.

OFA03

VISTA

IMAG

(PACS)

OFA03

APP

SPEC

OFA03

APP

SPEC

OFA03

CORRIDOR

AS2-302R-P2

C1

A1

A1

A1

A1 B1 A1 A1

A1

A1

C1

C1

A1

B1

C1

C1

B1

C1

K1

A1

K1

B1

B1

K1

B1

A1

A1

A1

A1

A1A1

A1

R1

R1

R1

R4 A1

R1

R1

R1 R1

R1 R4

R1

R4

R1

B1

A1 B1 A1

A1

R4 R4 R4

R4

R1K1

R1

R1

R1

K1

R1

R1

R1

R1

R1

R1

R1

R1

K1

R1

K1

R1

R1

R1

R1

R1

R1

R1

R1 R1

R1

R1 R1

R1

R1

K1

R1

R1

R1

R1

R1

R1

R1

K1

R1

R1

R1

R1

R1

R1

R1

R1

R1

R1 R1

R1

R1

K1

R1

R1

K1

R1

K1

R1

K1 K1

R1

K1

R1 R1

R1

R1

R1

R1

R1 R1

R1

R1 R1

R1

R1

A1 A1

A1

A1

A1

A1

A1C1

R4

K1

A1

A1

A1

A1

C2

A1

A1

R1

R1

K1

A1

A1

A1 A1

A1

B1 R3 R3

D1

A1

R1

C1

C2

R1

SIGNAL

AS2-302R-P2

C4

.1

B1

B1

C1

B1

A1

B1

A1

7' -2

'-1 1"

'-3

'-1 1"

6' -5

4' -0

5'

-5

CG-2 WP-1CG-1

CG-1

WP-1

CG-1

CG-1

WP-1

WP-1

AS2-113R-P2

AS2-113R-P2

AS9-111R-P2

6 6

K1

1'-0"CLEAR

5'-0"

NEW

UTILITIES

SHAFT

#3

EE1

EE1

ALIGN

C

LE

AR

5'

-1

0" AL

IG

N

CLEAR

6'-0"

4' -4

C1

7'-0"

EQ EQ

C

LE

AR

6'

-0

1' -2

'-0

6'-0"

6'-0"

ALIGN

AL

IG

N

ALIGN

ALIGN

5'-0"

5' -1

3' -1

"2 '-0

CLEAR

6'-0"

4"

A1

3 A1

R4

3 3 3 3

114'-5"

6'

-4 " 6'-10"

.3 B1

B1

1'-6"

.4

EE

AL

IG

N

ALIGN NEW

SHAFT WALL

TO CENTER

OF COLUMN

CG-1

CG-1

CG-1

WG-2WG-2

WG-2

CG-1CG-1

CG-1

CG-1

CG-1

WG-2

4"

12.5

.6

.2

.2

EE1

CG-1

CG-1

CG-1

CG-1

CG-1

CG-1

CG-1

CG-1CG-1

CG-1

CG-1

CG-1

EXISTING

CORRIDOR

TO

COMP/SERVER

ROOM

4"

4"

C2

C2

B1

B1

C2

1'-6"

COMM

ROOM

3' -0

13'-10"

BUILD NEW

PARTITION AGAINST

EXISTING STRUCTURE

'-6

'-3

'-1 0"

'-3

ALIGN

13'-7" 22'-9"

8'-0" 8'-0"

5'-7" 8'-0" 8'-0" 6'-11 1/2"

HR-1 (AS LABELED)

HR-2 (AS LABELED)

CG-1 (AS LABELED)

CG-2 (AS LABELED)

CG-3 (AS LABELED)

WG-1 (AS LABELED)

WG-2 (AS LABELED)

CHR-1 (AS LABELED)

WP-1 (AS LABELED)

WALL PROTECTION LEGEND

HANDRAIL 1

HANDRAIL 2

CORNER GUARD 1

CORNER GUARD 2

CORNER GUARD 3

WALL GUARD 1

WALL GUARD 2

CHAIR RAIL 1

SHEET WALL

PROTECTION 1

72" AFF TYPICAL

on e-ei gh th in ch o ne fo ot on e-qu ar te r i nc h on e fo ot th re e-ei gh th in ch o ne fo ot on e-ha lf in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot

6" on e in ch o ne fo ot on e an d on e-ha lf in ch o ne fo ot th re e in ch es o ne fo ot

6"

6"

6"

Drawing number

Drawn

Building Number

Location

Project Title

Date

Project Number

Checked by

Drawing Title

Approved : Project Director

1 2 3 4 5 6

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9

CONSULTANTS: ARCHITECTS/ENGINEERS Office of Construction and Facilities Management

Department of Veterans Affairs

7 8 9

BUILDING PARTIALLY SPRINKLERED (RENOVATED SPACES/

NEW PENTHOUSES IN THIS SCOPE OF WORK 100% SPRINKLERED )

BID SET 06/12/2015

GAUTIER de TORRES ARQUITECTOS Apartado 19357, San Juan, Puerto Rico 00910-1357

DEGENKOLB ENGINEERS

235 MONTGOMERY ST, SAN FRANCISCO, CA 94104

SAQ ENVIROMENTAL ENGINEERS, INC

PO.BOX 155, MANATI, PR 00674

LASALLE ENGINEERING, LLC

1000 YORK ROAD WILLOW GROVE, PA 19090

M.A + ASSOCIATES, LLC

8655 CHERRY LANE, LAUREL, MD 20707

CT + ASSOCIATES, LLC

86 THOMAS LEIGHTON BLVD, CUMBERLAND, RHODE ISLAND 02864

OPA

KEY PLAN

BLDG−1

ADMIN

SOUTH

BED

TWR

N

BID SET 06/12/2015

Z:

\14

2-

VA

CH

S

SE

IS

MI

C

TA

SK

CD

\G

DT

\LO

CA

L F

ILE

S\

MA

RA

\17

A-

GD

TV

AS

J-C

EN

TR

AL

_m ar a.r vt 6/1

2/2

5 2 :09

:13 P

M

AS2-112R-P2

ENLARGED ARCHITECTURAL PLAN-THIRD

FLOOR

ED MR06/12/2015

672-085APHASE 3 BUILDING ONE-SEISMIC

CORRECTIONS AND RENOVATIONS

VA Caribbean Healthcare System 10 Casia Street, San Juan, PR 00921-3201

1101 King Street Suite 400, Alexandria, VA 22314

1/8" = 1'-0"1 ENLARGED ARCHITECTURAL PLAN-THIRD FLOOR-P2

GENERAL SHEET NOTES

1 FOR GENERAL NOTES, SEE SHEETS GN-001 & GN-002.

2 FOR DEMOLITION NOTES, SEE AD1-100R SERIES.

3 FOR SYMBOLS LEGEND AND ABBREVIATIONS, SEE SHEET GN-001.

4 RENOVATION WORK AT FIRST FLOOR SHALL BE BROKEN OUT INTO TWO (2)

DIFFERENT PHASES OR WORK (P1 AND P2).

5 FOR PARTITION TYPES, SEE AS8-300R SERIES.

6 FOR INTERIOR ALUMINUM AND GLASS DOORS AND SIDELIGHTS DETAILS, SEE

AS8-100R SERIES.

7 FOR ENLARGED TOILET ROOM PLANS, SEE AS2-300R SERIES.

8 FOR ENLARGED EQUIPMENT PLANS, SEE AS9-100R SERIES.

9 SEE FLOOR PLANS, ELEVATIONS, AND CEILING PLANS FOR LOCATIONS OF

EXPANSION JOINT ASSEMBLIES. SEE SPECIFICATION SECTION 07 95 13 FOR

PARAMETERS REGARDING THESE JOINTS.

10 ALL NEW STURCTURAL MEMBERS TO HAVE NEW APPLIED FIRE-PROOFING.

11 THE CONTRACTOR SHALL SEISMICALLY BRACE ALL EXISTING AND NEW

NON-STRUCTURAL ELEMENTS WITHIN RENOVATION "CONSTRUCTION LIMIT" AS

REQUIRED BY CODE. REFER TO SPCIFICATION SECTION 130541 (SEISMIC

RESTRAINT REQUIREMENTS FOR NON-STRUCTURAL COMPONENTS) FOR

ADDITIONAL INFORMATION.

12 FOR STRUCTURAL SUPPORT AT WALL MOUNTED ITEMS SEE AS7-400R SERIES.

13 WHERE PARTITION TYPE C1 IS USED ON THE PERIMETER OF SMOKE

COMPARTMENTS (REFER TO LIFE SAFETY DRAWINGS) IT SHALL BE BUILT TO

SATISFY THE REQUIREMENTS OF A SMOKE BARRIER.

14 FOLLOWING CONSTRUCTION, REMOVE TEMPORATY PARTITIONS (E1T, E2T, E3T)

AROUND CONSTRUCTION AREA. REPAIR FINISHES IN FLOOR, WALLS AND

CEILING.

15 EXISTING COLUMNS ARE CURRENTLY ENCASED IN CONCRETE. RENOVATION

SCOPE OF WORK REQUIRES ALL EXISTING COLUMNS TO BE FINISHED WITH A

TYPE "R" PARTITION UNLESS OTHERWISE NOTED. REFER TO WALL TAGS ON

ENLARGED PLANS. SEE SHEET AS8-301R FOR PARTITION TYPES AND SCHEDULE.

16 PROVIDE FIRE DAMPER IF EXISTING DUCTS HAVE OPENINGS INTO THE

PASSAGEWAY (CORRIDOR).

KEYNOTES P2

2 THE CONTRACTOR SHALL FURNISH AND INSTALL NEW FLOOR DRAINS AT THE

EXISTING CONCRETE/STEEL DECK SLAB AS SHOWN AND SLOPE THE FLOOR

TOWARD THE FLOOR DRAIN. THE FLOOR DRAIN SHALL BE THE LOW POINT OF

THE FLOOR. PROVIDE A METAL SUPPORT PLATE WHEN DRAIN IS INSTALLED IN

AN EXISTING FLOOR; CAULK AROUND DRAIN PRIOR TO RE-GROUTING. FLOOR

DRAIN LOCATION SHOWN FOR REFERENCE ONLY. GENERAL CONTRACTOR SHALL

COORDINATE FINAL FLOOR DRAIN LOCATION PER VA GUIDELINES AND PLUMBING

PLANS.

3 WHERE NEW PARTITION C1 AND K1 MEET EXISTING WALL, NEW PARTITION SHALL

ALIGN OR CONTINUE FROM EXISTING WALL AND INTEGRITY OF MOST

RESTRICTIVE FIRE OR SMOKE RATING SHALL BE PRESERVED THROUGHOUT.

4 RELOCATE DOORS THAT WERE REMOVED AND SALVAGED DURING PHASE 1

TEMPORARY CONSTRUCTION. REFURBISH TO MATCH EXISTING. TO BE APPROVED

BY RESIDENT PROJECT ARCHITECT

5 INSTALL NEW PARTITION IN ORDER TO ENCLOSE EXISTING SPACE CONSISTENT

WITH ORIGINAL LAYOUT. NEW PARTITION SHALL BE FURNISHED AND FINISHED TO

MATCH EXISTING. TO BE APPROVED BY RESIDENT ENGINEER.

6 PLUMBING CHASE. GENERAL CONTRACTOR TO COORDINATE WITH PLUMBING

PLANS.

7 MECHANICAL CHASE. GENERAL CONTRACTOR TO COORDINATE WITH

MECHANICAL PLANS.

8 INSTALL SHAFT WALL AFTER TEMPORARY HYDRAULIC ELEVATOR REMOVAL IS

COMPLETED.

9 SINKS SHOWN FOR REFERENCE ONLY. TO BE PURCHASED AND INSTALLED BY

VCS.

WALL PROTECTION SHEET NOTES

1 SEE SHEET AS7-402R FOR TYPICAL WALL PROTECTION DETAILS.

2 CRASH RAIL, HANDRAIL, AND CHAIR RAIL TO START AND STOP 3" FROM CORNERS,

UNLESS OTHERWISE NOTED.

3 ALL OUTSIDE CORNERS TO RECEIVE CORNER GUARD, UNLESS OTHERWISE

NOTED.

4 ALL WALL PROTECTION EDGES TO RECEIVE CAULK TO ADJACENT SURFACES.

5 HANDRAIL TO STOP 2" FROM FIRE EXTINGUISHER CABINETS (FEC).

6 EXTEND ALL SHEET WALL PROTECTION TO ALL INSIDE AND OUTSIDE CORNERS IN

ENCLOSED ROOMS AND ALCOVES.

7 TYPICAL HEIGHT OF ALL WALL GUARDS TO BE 12" AFF ON CENTER.

8 TYPICAL HEIGHT OF ALL CHAIR RAILS AND HANDRAILS TO BE 32" AFF.

9 TYPICAL HEIGHT OF SHEET WALL PROTECTION TO BE 72".

NO REVISIONS DATE

SEE REVISED

DRAWING

AMENDMENT 9

(A-9003)

7/07/15

SUBMITTAL

08 71 00 - 01

2/27/17

RFI 0059

RFI 0186