S03 - ENCL10_PROJ_REFERENCED_3-FLOOR_AS2-112R-P2_ENLARGED ARC_PLAN_672-20-603.pdf
PDF 437 KB Posted
- Attached to
- C1DA--NRM (PROJ 672-20-603) A-E Provide Fire Sprinkler System Throughout Main Building Number 1.
- Solicitation number
- 36C24821R0044
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FD
M
L
K
J
H
G
7 8 9 10
11 12
3004 3005
3100.1
OFFICE
CHIEF
OFM1
SECRETARY
WAITING
OFA1
DEPUTY
CHIEF
OFA1
HRDW
TEAM
LEADER
OFA1
RESOURCE
MANAGER
OFA1
CONFERENCE
ROOM
CRA02
REFERENCE
LIBRARY
NETWORK
MANAGER
OFA1
PROJECT
WORK
AREA
OFA03
STAFF
LOUNGE
SL001
VISTA
SYSTEM
ADMIN
OFA03
VISTA
SYSTEM
ADMIN
OFA03
IT SPEC.
OFA03
INTERN
OFA03
IT SPEC.
OFA03
APP
SPEC.
OFA03
IT SPEC.
OFA03
IT SPEC.
OFA03
IT SPEC.
OFA03
IT SPEC.
OFA03
IT SPEC.
OFA03
IT SPEC.
OFA03
IT SPEC.
OFA03
IT SPEC.
OFA03
IT SPEC.
OFA03
NETWORK
ADMIN
OFA03
APP
COOR.
OFA03
EXIST.
STAIR #1
MALE
TOILET
TLTU1
FEMALE
TOILET
TLTU1
NETWORK
ADMIN
OFD01
IT SPEC
OFA03
IT SPEC
OFA03
IT SPEC
OFA03
HELP
DESK
SPEC.
OFA03
HELP
DESK
SPEC.
OFA03
HELP
DESK
SPEC.
OFA03
STAGING
INVENTORY
SUBWAIT
WRC01
SUPERVISOR
INVENTORY
OFD01
STAGING/INVENTORY
CONTROL
APP
SPEC.
OFA03
APP
SPEC.
OFA03
APP
SPEC.
OFA03
INTERN
OFA03
IT SPEC
OFA03
OUTGOING
INVENTORY
CONTROL
EXIST.ELEC
CLOSET
EXIST.
COMM
ROOM
JANITOR
3107.1
JANC01
JANITOR
3107.2
JANC01
SHELL
SPACE
FUTURE
COMPUTER
ROOM
(N.I.C.)
EXIST.
STAIR
#2A
EXIST.
STAIR #2
EXIST.
ELEVATOR
#2
EXIST.
ELEVATOR
#1
UTILITIES
SHAFT
#1
EXIST.
ELEVATOR
#4
UTILITIES
SHAFT
#2
EXIST.
SERVICE
ELEVATOR
EXIST.
SERVICE
ELEVATOR
WORKSHOP
FUTURE
OFFICE
SPACE
IT SPEC
OFA03
HELP
DESK
SUP.
OAD01
HELP
SUBWAIT
WRC01
EXIST.
ELEC.
CLOSET
EXIST.
CHASE
COMM
ROOM
EXIST.
CHASE
AS2-302R-P2
B5
SERVICE
LOBBY
AS2-302R-P2
A1
AS2-302R-P2
B1
INTERN
OFA03
IT SPEC.
OFA03
IT SPEC
OFA03
CORRIDOR
VISTA
IMAG
(PACS)
OFA03
VISTA
SYSTEM
ADMIN
OFA03
APP
COOR.
OFA03
VISTA
IMAG
(PACS)
OFA03
APP
SPEC
OFA03
APP
SPEC
OFA03
CORRIDOR
AS2-302R-P2
C1
A1
A1
A1
A1 B1 A1 A1
A1
A1
C1
C1
A1
B1
C1
C1
B1
C1
K1
A1
K1
B1
B1
K1
B1
A1
A1
A1
A1
A1A1
A1
R1
R1
R1
R4 A1
R1
R1
R1 R1
R1 R4
R1
R4
R1
B1
A1 B1 A1
A1
R4 R4 R4
R4
R1K1
R1
R1
R1
K1
R1
R1
R1
R1
R1
R1
R1
R1
K1
R1
K1
R1
R1
R1
R1
R1
R1
R1
R1 R1
R1
R1 R1
R1
R1
K1
R1
R1
R1
R1
R1
R1
R1
K1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1 R1
R1
R1
K1
R1
R1
K1
R1
K1
R1
K1 K1
R1
K1
R1 R1
R1
R1
R1
R1
R1 R1
R1
R1 R1
R1
R1
A1 A1
A1
A1
A1
A1
A1C1
R4
K1
A1
A1
A1
A1
C2
A1
A1
R1
R1
K1
A1
A1
A1 A1
A1
B1 R3 R3
D1
A1
R1
C1
C2
R1
SIGNAL
AS2-302R-P2
C4
B1
B1
C1
B1
A1
B1
A1
CG-2
WP-1
CG-1
CG-1
WP-1
CG-1
CG-1
WP-1
WP-1
AS2-113R-P2
AS2-113R-P2
AS9-111R-P2
6 6
K1
1'-0"
5'-0"
CLEAR
NEW
UTILITIES
SHAFT
#3
EE1
EE1
ALIGN
C L
E A
R
A L
I G
N
6'-0"
CLEAR
C1
7'-0"
EQ EQ
C L
E A
R
6'-0"
6'-0"
ALIGN
A L
I G
N
ALIGN
ALIGN
5'-0"
6'-0"
CLEAR
4"
A1
A1
R4
3 3 3 3
114'-5"
6'-10"
3 B1
B1
1'-6"
EE
A L
I G
N
ALIGN NEW
SHAFT WALL
TO CENTER
OF COLUMN
CG-1
CG-1
CG-1
WG-2WG-2
WG-2
CG-1CG-1
CG-1
CG-1
CG-1
WG-2
4"
12.5
EE1
CG-1
CG-1
CG-1
CG-1
CG-1
CG-1
CG-1
CG-1
CG-1
CG-1
CG-1
CG-1
EXISTING
CORRIDOR
TO
COMP/SERVER
ROOM
4"
4"
C2
C2
B1
B1
C2
1'-6"
COMM
ROOM
13'-10"
BUILD NEW
PARTITION AGAINST
EXISTING STRUCTURE
ALIGN
13'-7" 22'-9"
8'-0" 8'-0"
5'-7" 8'-0" 8'-0" 6'-11 1/2"
HR-1 (AS LABELED)
HR-2 (AS LABELED)
CG-1 (AS LABELED)
CG-2 (AS LABELED)
CG-3 (AS LABELED)
WG-1 (AS LABELED)
WG-2 (AS LABELED)
CHR-1 (AS LABELED)
WP-1 (AS LABELED)
WALL PROTECTION LEGEND
HANDRAIL 1
HANDRAIL 2
CORNER GUARD 1
CORNER GUARD 2
CORNER GUARD 3
WALL GUARD 1
WALL GUARD 2
CHAIR RAIL 1
SHEET WALL
PROTECTION 1
72" AFF TYPICAL
o n e e i g h t h i n c o e f o o t o n e q u a r t e r i n e f o o t t h r e e e i g h t i e f o o t o n e h a l f i n e f o o t t h r e e q u a r t e r s i n e f o o t o n e i n e f o o t o n e a n d o n e h a l f i n e f o o t t h r e e i n c h e s e f o o t
CONSULTANTS: ARCHITECTS/ENGINEERS Office of Construction and Facilities Management
Department of
Veterans Affairs
BUILDING PARTIALLY SPRINKLERED (RENOVATED SPACES/
NEW PENTHOUSES IN THIS SCOPE OF WORK 100% SPRINKLERED )
BID SET 06/12/2015
GAUTIER de TORRES ARQUITECTOS Apartado 19357, San Juan, Puerto Rico 00910-1357
DEGENKOLB ENGINEERS
235 MONTGOMERY ST, SAN FRANCISCO, CA 94104
SAQ ENVIROMENTAL ENGINEERS, INC
PO.BOX 155, MANATI, PR 00674
LASALLE ENGINEERING, LLC
1000 YORK ROAD WILLOW GROVE, PA 19090
M.A + ASSOCIATES, LLC
8655 CHERRY LANE, LAUREL, MD 20707
CT + ASSOCIATES, LLC
86 THOMAS LEIGHTON BLVD, CUMBERLAND, RHODE ISLAND 02864
KEY PLAN
BID SET 06/12/2015
N:
\14
2-
VA
CH
S
SE
IS
MI
C
TA
SK
CD
\G
DT
\LO
CA
L F
ILE
S\
JO
SE
MI
LIO
\17
A-
GD
TV
AS
J-C
EN
TR
AL
_jo se mi lio .fe rre r.r vt 3/1
8/2
6 1 2:0
7:1 6 P
M
AS2-112R-P2
ENLARGED ARCHITECTURAL PLAN-THIRD
FLOOR
ED MR06/12/2015
672-085APHASE 3 BUILDING ONE-SEISMIC
CORRECTIONS AND RENOVATIONS
VA Caribbean Healthcare System 10 Casia Street, San Juan, PR 00921-3201
1101 King Street Suite 400, Alexandria, VA 22314
1/8" = 1'-0"
ENLARGED ARCHITECTURAL PLAN-THIRD FLOOR-P2
GENERAL SHEET NOTES
1 FOR GENERAL NOTES, SEE SHEETS GN-001 & GN-002.
2 FOR DEMOLITION NOTES, SEE AD1-100R SERIES.
3 FOR SYMBOLS LEGEND AND ABBREVIATIONS, SEE SHEET GN-001.
4 RENOVATION WORK AT FIRST FLOOR SHALL BE BROKEN OUT INTO TWO (2)
DIFFERENT PHASES OR WORK (P1 AND P2).
5 FOR PARTITION TYPES, SEE AS8-300R SERIES.
6 FOR INTERIOR ALUMINUM AND GLASS DOORS AND SIDELIGHTS DETAILS, SEE
AS8-100R SERIES.
7 FOR ENLARGED TOILET ROOM PLANS, SEE AS2-300R SERIES.
8 FOR ENLARGED EQUIPMENT PLANS, SEE AS9-100R SERIES.
9 SEE FLOOR PLANS, ELEVATIONS, AND CEILING PLANS FOR LOCATIONS OF
EXPANSION JOINT ASSEMBLIES. SEE SPECIFICATION SECTION 07 95 13 FOR
PARAMETERS REGARDING THESE JOINTS.
10 ALL NEW STURCTURAL MEMBERS TO HAVE NEW APPLIED FIRE-PROOFING.
11 THE CONTRACTOR SHALL SEISMICALLY BRACE ALL EXISTING AND NEW
NON-STRUCTURAL ELEMENTS WITHIN RENOVATION "CONSTRUCTION LIMIT" AS
REQUIRED BY CODE. REFER TO SPCIFICATION SECTION 130541 (SEISMIC
RESTRAINT REQUIREMENTS FOR NON-STRUCTURAL COMPONENTS) FOR
ADDITIONAL INFORMATION.
12 FOR STRUCTURAL SUPPORT AT WALL MOUNTED ITEMS SEE AS7-400R SERIES.
13 WHERE PARTITION TYPE C1 IS USED ON THE PERIMETER OF SMOKE
COMPARTMENTS (REFER TO LIFE SAFETY DRAWINGS) IT SHALL BE BUILT TO
SATISFY THE REQUIREMENTS OF A SMOKE BARRIER.
14 FOLLOWING CONSTRUCTION, REMOVE TEMPORATY PARTITIONS (E1T, E2T, E3T)
AROUND CONSTRUCTION AREA. REPAIR FINISHES IN FLOOR, WALLS AND
CEILING.
15 EXISTING COLUMNS ARE CURRENTLY ENCASED IN CONCRETE. RENOVATION
SCOPE OF WORK REQUIRES ALL EXISTING COLUMNS TO BE FINISHED WITH A
TYPE "R" PARTITION UNLESS OTHERWISE NOTED. REFER TO WALL TAGS ON
ENLARGED PLANS. SEE SHEET AS8-301R FOR PARTITION TYPES AND SCHEDULE.
16 PROVIDE FIRE DAMPER IF EXISTING DUCTS HAVE OPENINGS INTO THE
PASSAGEWAY (CORRIDOR).
KEYNOTES P2
2 THE CONTRACTOR SHALL FURNISH AND INSTALL NEW FLOOR DRAINS AT THE
EXISTING CONCRETE/STEEL DECK SLAB AS SHOWN AND SLOPE THE FLOOR
TOWARD THE FLOOR DRAIN. THE FLOOR DRAIN SHALL BE THE LOW POINT OF
THE FLOOR. PROVIDE A METAL SUPPORT PLATE WHEN DRAIN IS INSTALLED IN
AN EXISTING FLOOR; CAULK AROUND DRAIN PRIOR TO RE-GROUTING. FLOOR
DRAIN LOCATION SHOWN FOR REFERENCE ONLY. GENERAL CONTRACTOR SHALL
COORDINATE FINAL FLOOR DRAIN LOCATION PER VA GUIDELINES AND PLUMBING
PLANS.
3 WHERE NEW PARTITION C1 AND K1 MEET EXISTING WALL, NEW PARTITION SHALL
ALIGN OR CONTINUE FROM EXISTING WALL AND INTEGRITY OF MOST
RESTRICTIVE FIRE OR SMOKE RATING SHALL BE PRESERVED THROUGHOUT.
4 RELOCATE DOORS THAT WERE REMOVED AND SALVAGED DURING PHASE 1
TEMPORARY CONSTRUCTION. REFURBISH TO MATCH EXISTING. TO BE APPROVED
BY RESIDENT PROJECT ARCHITECT
5 INSTALL NEW PARTITION IN ORDER TO ENCLOSE EXISTING SPACE CONSISTENT
WITH ORIGINAL LAYOUT. NEW PARTITION SHALL BE FURNISHED AND FINISHED TO
MATCH EXISTING. TO BE APPROVED BY RESIDENT ENGINEER.
6 PLUMBING CHASE. GENERAL CONTRACTOR TO COORDINATE WITH PLUMBING
PLANS.
7 MECHANICAL CHASE. GENERAL CONTRACTOR TO COORDINATE WITH
MECHANICAL PLANS.
8 INSTALL SHAFT WALL AFTER TEMPORARY HYDRAULIC ELEVATOR REMOVAL IS
COMPLETED.
9 SINKS SHOWN FOR REFERENCE ONLY. TO BE PURCHASED AND INSTALLED BY
VCS.
WALL PROTECTION SHEET NOTES
1 SEE SHEET AS7-402R FOR TYPICAL WALL PROTECTION DETAILS.
2 CRASH RAIL, HANDRAIL, AND CHAIR RAIL TO START AND STOP 3" FROM CORNERS,
UNLESS OTHERWISE NOTED.
3 ALL OUTSIDE CORNERS TO RECEIVE CORNER GUARD, UNLESS OTHERWISE
NOTED.
4 ALL WALL PROTECTION EDGES TO RECEIVE CAULK TO ADJACENT SURFACES.
5 HANDRAIL TO STOP 2" FROM FIRE EXTINGUISHER CABINETS (FEC).
6 EXTEND ALL SHEET WALL PROTECTION TO ALL INSIDE AND OUTSIDE CORNERS IN
ENCLOSED ROOMS AND ALCOVES.
7 TYPICAL HEIGHT OF ALL WALL GUARDS TO BE 12" AFF ON CENTER.
8 TYPICAL HEIGHT OF ALL CHAIR RAILS AND HANDRAILS TO BE 32" AFF.
9 TYPICAL HEIGHT OF SHEET WALL PROTECTION TO BE 72".
NO REVISIONS DATE
SUBMITTAL 08 71 00-01 02/17/2017
RFI 0186
WALSH PUERTO RICO
RECEIVED
FEB 27 2017
RFI 0059
M
L
K
J
H
G
7 8 9 10
11 12
3004 3005
.1
.1
3100.1
.4
.2
.2
.1 31
.2
.3
.3
.5
OFFICE
CHIEF
OFM1
SECRETARY
WAITING
OFA1
DEPUTY
CHIEF
OFA1
HRDW
TEAM
LEADER
OFA1
RESOURCE
MANAGER
OFA1
CONFERENCE
ROOM
CRA02
REFERENCE
LIBRARY
NETWORK
MANAGER
OFA1
PROJECT
WORK
AREA
OFA03
STAFF
LOUNGE
SL001
VISTA
SYSTEM
ADMIN
OFA03
VISTA
SYSTEM
ADMIN
OFA03
IT SPEC.
OFA03 INTERN
OFA03
IT SPEC.
OFA03
APP
SPEC.
OFA03
IT SPEC.
OFA03
IT SPEC.
OFA03
IT SPEC.
OFA03
IT SPEC.
OFA03 IT SPEC.
OFA03
IT SPEC.
OFA03
IT SPEC.
OFA03
IT SPEC.
OFA03
IT SPEC.
OFA03
NETWORK
ADMIN
OFA03
APP
COOR.
OFA03
EXIST.
STAIR #1
MALE
TOILET
TLTU1
FEMALE
TOILET
TLTU1
NETWORK
ADMIN
OFD01
IT SPEC
OFA03
IT SPEC
OFA03
IT SPEC
OFA03
HELP
DESK
SPEC.
OFA03
HELP
DESK
SPEC.
OFA03
HELP
DESK
SPEC.
OFA03
STAGING
INVENTORY
SUBWAIT
WRC01
SUPERVISOR
INVENTORY
OFD01 STAGING/INVENTORY
CONTROL
APP
SPEC.
OFA03
APP
SPEC.
OFA03
APP
SPEC.
OFA03
INTERN
OFA03
IT SPEC
OFA03
OUTGOING
INVENTORY
CONTROL
EXIST.ELEC
CLOSET
EXIST.
COMM
ROOM
JANITOR
3107.1
JANC01 JANITOR
3107.2
JANC01
SHELL
SPACE
FUTURE
COMPUTER
ROOM
(N.I.C.)
EXIST.
STAIR
#2A
EXIST.
STAIR #2
EXIST.
ELEVATOR
#2
EXIST.
ELEVATOR
#1
UTILITIES
SHAFT
#1
EXIST.
ELEVATOR
#4
UTILITIES
SHAFT
#2
EXIST.
SERVICE
ELEVATOR
EXIST.
SERVICE
ELEVATOR
WORKSHOP
FUTURE
OFFICE
SPACE
IT SPEC
OFA03
HELP
DESK
SUP.
OAD01
HELP
SUBWAIT
WRC01
EXIST.
ELEC.
CLOSET
EXIST.
CHASE
COMM
ROOM
EXIST.
CHASE
AS2-302R-P2
B5
SERVICE
LOBBY
AS2-302R-P2
A1
AS2-302R-P2
B1
INTERN
OFA03
IT SPEC.
OFA03
IT SPEC
OFA03
CORRIDOR
VISTA
IMAG
(PACS)
OFA03
VISTA
SYSTEM
ADMIN
OFA03
APP
COOR.
OFA03
VISTA
IMAG
(PACS)
OFA03
APP
SPEC
OFA03
APP
SPEC
OFA03
CORRIDOR
AS2-302R-P2
C1
A1
A1
A1
A1 B1 A1 A1
A1
A1
C1
C1
A1
B1
C1
C1
B1
C1
K1
A1
K1
B1
B1
K1
B1
A1
A1
A1
A1
A1A1
A1
R1
R1
R1
R4 A1
R1
R1
R1 R1
R1 R4
R1
R4
R1
B1
A1 B1 A1
A1
R4 R4 R4
R4
R1K1
R1
R1
R1
K1
R1
R1
R1
R1
R1
R1
R1
R1
K1
R1
K1
R1
R1
R1
R1
R1
R1
R1
R1 R1
R1
R1 R1
R1
R1
K1
R1
R1
R1
R1
R1
R1
R1
K1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1 R1
R1
R1
K1
R1
R1
K1
R1
K1
R1
K1 K1
R1
K1
R1 R1
R1
R1
R1
R1
R1 R1
R1
R1 R1
R1
R1
A1 A1
A1
A1
A1
A1
A1C1
R4
K1
A1
A1
A1
A1
C2
A1
A1
R1
R1
K1
A1
A1
A1 A1
A1
B1 R3 R3
D1
A1
R1
C1
C2
R1
SIGNAL
AS2-302R-P2
C4
.1
B1
B1
C1
B1
A1
B1
A1
7' -2
'-1 1"
'-3
'-1 1"
6' -5
4' -0
5'
-5
CG-2 WP-1CG-1
CG-1
WP-1
CG-1
CG-1
WP-1
WP-1
AS2-113R-P2
AS2-113R-P2
AS9-111R-P2
6 6
K1
1'-0"CLEAR
5'-0"
NEW
UTILITIES
SHAFT
#3
EE1
EE1
ALIGN
C
LE
AR
5'
-1
0" AL
IG
N
CLEAR
6'-0"
4' -4
C1
7'-0"
EQ EQ
C
LE
AR
6'
-0
1' -2
'-0
6'-0"
6'-0"
ALIGN
AL
IG
N
ALIGN
ALIGN
5'-0"
5' -1
3' -1
"2 '-0
CLEAR
6'-0"
4"
A1
3 A1
R4
3 3 3 3
114'-5"
6'
-4 " 6'-10"
.3 B1
B1
1'-6"
.4
EE
AL
IG
N
ALIGN NEW
SHAFT WALL
TO CENTER
OF COLUMN
CG-1
CG-1
CG-1
WG-2WG-2
WG-2
CG-1CG-1
CG-1
CG-1
CG-1
WG-2
4"
12.5
.6
.2
.2
EE1
CG-1
CG-1
CG-1
CG-1
CG-1
CG-1
CG-1
CG-1CG-1
CG-1
CG-1
CG-1
EXISTING
CORRIDOR
TO
COMP/SERVER
ROOM
4"
4"
C2
C2
B1
B1
C2
1'-6"
COMM
ROOM
3' -0
13'-10"
BUILD NEW
PARTITION AGAINST
EXISTING STRUCTURE
'-6
'-3
'-1 0"
'-3
ALIGN
13'-7" 22'-9"
8'-0" 8'-0"
5'-7" 8'-0" 8'-0" 6'-11 1/2"
HR-1 (AS LABELED)
HR-2 (AS LABELED)
CG-1 (AS LABELED)
CG-2 (AS LABELED)
CG-3 (AS LABELED)
WG-1 (AS LABELED)
WG-2 (AS LABELED)
CHR-1 (AS LABELED)
WP-1 (AS LABELED)
WALL PROTECTION LEGEND
HANDRAIL 1
HANDRAIL 2
CORNER GUARD 1
CORNER GUARD 2
CORNER GUARD 3
WALL GUARD 1
WALL GUARD 2
CHAIR RAIL 1
SHEET WALL
PROTECTION 1
72" AFF TYPICAL
on e-ei gh th in ch o ne fo ot on e-qu ar te r i nc h on e fo ot th re e-ei gh th in ch o ne fo ot on e-ha lf in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot
6" on e in ch o ne fo ot on e an d on e-ha lf in ch o ne fo ot th re e in ch es o ne fo ot
6"
6"
6"
Drawing number
Drawn
Building Number
Location
Project Title
Date
Project Number
Checked by
Drawing Title
Approved : Project Director
1 2 3 4 5 6
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
CONSULTANTS: ARCHITECTS/ENGINEERS Office of Construction and Facilities Management
Department of Veterans Affairs
7 8 9
BUILDING PARTIALLY SPRINKLERED (RENOVATED SPACES/
NEW PENTHOUSES IN THIS SCOPE OF WORK 100% SPRINKLERED )
BID SET 06/12/2015
GAUTIER de TORRES ARQUITECTOS Apartado 19357, San Juan, Puerto Rico 00910-1357
DEGENKOLB ENGINEERS
235 MONTGOMERY ST, SAN FRANCISCO, CA 94104
SAQ ENVIROMENTAL ENGINEERS, INC
PO.BOX 155, MANATI, PR 00674
LASALLE ENGINEERING, LLC
1000 YORK ROAD WILLOW GROVE, PA 19090
M.A + ASSOCIATES, LLC
8655 CHERRY LANE, LAUREL, MD 20707
CT + ASSOCIATES, LLC
86 THOMAS LEIGHTON BLVD, CUMBERLAND, RHODE ISLAND 02864
OPA
KEY PLAN
BLDG−1
ADMIN
SOUTH
BED
TWR
N
BID SET 06/12/2015
Z:
\14
2-
VA
CH
S
SE
IS
MI
C
TA
SK
CD
\G
DT
\LO
CA
L F
ILE
S\
MA
RA
\17
A-
GD
TV
AS
J-C
EN
TR
AL
_m ar a.r vt 6/1
2/2
5 2 :09
:13 P
M
AS2-112R-P2
ENLARGED ARCHITECTURAL PLAN-THIRD
FLOOR
ED MR06/12/2015
672-085APHASE 3 BUILDING ONE-SEISMIC
CORRECTIONS AND RENOVATIONS
VA Caribbean Healthcare System 10 Casia Street, San Juan, PR 00921-3201
1101 King Street Suite 400, Alexandria, VA 22314
1/8" = 1'-0"1 ENLARGED ARCHITECTURAL PLAN-THIRD FLOOR-P2
GENERAL SHEET NOTES
1 FOR GENERAL NOTES, SEE SHEETS GN-001 & GN-002.
2 FOR DEMOLITION NOTES, SEE AD1-100R SERIES.
3 FOR SYMBOLS LEGEND AND ABBREVIATIONS, SEE SHEET GN-001.
4 RENOVATION WORK AT FIRST FLOOR SHALL BE BROKEN OUT INTO TWO (2)
DIFFERENT PHASES OR WORK (P1 AND P2).
5 FOR PARTITION TYPES, SEE AS8-300R SERIES.
6 FOR INTERIOR ALUMINUM AND GLASS DOORS AND SIDELIGHTS DETAILS, SEE
AS8-100R SERIES.
7 FOR ENLARGED TOILET ROOM PLANS, SEE AS2-300R SERIES.
8 FOR ENLARGED EQUIPMENT PLANS, SEE AS9-100R SERIES.
9 SEE FLOOR PLANS, ELEVATIONS, AND CEILING PLANS FOR LOCATIONS OF
EXPANSION JOINT ASSEMBLIES. SEE SPECIFICATION SECTION 07 95 13 FOR
PARAMETERS REGARDING THESE JOINTS.
10 ALL NEW STURCTURAL MEMBERS TO HAVE NEW APPLIED FIRE-PROOFING.
11 THE CONTRACTOR SHALL SEISMICALLY BRACE ALL EXISTING AND NEW
NON-STRUCTURAL ELEMENTS WITHIN RENOVATION "CONSTRUCTION LIMIT" AS
REQUIRED BY CODE. REFER TO SPCIFICATION SECTION 130541 (SEISMIC
RESTRAINT REQUIREMENTS FOR NON-STRUCTURAL COMPONENTS) FOR
ADDITIONAL INFORMATION.
12 FOR STRUCTURAL SUPPORT AT WALL MOUNTED ITEMS SEE AS7-400R SERIES.
13 WHERE PARTITION TYPE C1 IS USED ON THE PERIMETER OF SMOKE
COMPARTMENTS (REFER TO LIFE SAFETY DRAWINGS) IT SHALL BE BUILT TO
SATISFY THE REQUIREMENTS OF A SMOKE BARRIER.
14 FOLLOWING CONSTRUCTION, REMOVE TEMPORATY PARTITIONS (E1T, E2T, E3T)
AROUND CONSTRUCTION AREA. REPAIR FINISHES IN FLOOR, WALLS AND
CEILING.
15 EXISTING COLUMNS ARE CURRENTLY ENCASED IN CONCRETE. RENOVATION
SCOPE OF WORK REQUIRES ALL EXISTING COLUMNS TO BE FINISHED WITH A
TYPE "R" PARTITION UNLESS OTHERWISE NOTED. REFER TO WALL TAGS ON
ENLARGED PLANS. SEE SHEET AS8-301R FOR PARTITION TYPES AND SCHEDULE.
16 PROVIDE FIRE DAMPER IF EXISTING DUCTS HAVE OPENINGS INTO THE
PASSAGEWAY (CORRIDOR).
KEYNOTES P2
2 THE CONTRACTOR SHALL FURNISH AND INSTALL NEW FLOOR DRAINS AT THE
EXISTING CONCRETE/STEEL DECK SLAB AS SHOWN AND SLOPE THE FLOOR
TOWARD THE FLOOR DRAIN. THE FLOOR DRAIN SHALL BE THE LOW POINT OF
THE FLOOR. PROVIDE A METAL SUPPORT PLATE WHEN DRAIN IS INSTALLED IN
AN EXISTING FLOOR; CAULK AROUND DRAIN PRIOR TO RE-GROUTING. FLOOR
DRAIN LOCATION SHOWN FOR REFERENCE ONLY. GENERAL CONTRACTOR SHALL
COORDINATE FINAL FLOOR DRAIN LOCATION PER VA GUIDELINES AND PLUMBING
PLANS.
3 WHERE NEW PARTITION C1 AND K1 MEET EXISTING WALL, NEW PARTITION SHALL
ALIGN OR CONTINUE FROM EXISTING WALL AND INTEGRITY OF MOST
RESTRICTIVE FIRE OR SMOKE RATING SHALL BE PRESERVED THROUGHOUT.
4 RELOCATE DOORS THAT WERE REMOVED AND SALVAGED DURING PHASE 1
TEMPORARY CONSTRUCTION. REFURBISH TO MATCH EXISTING. TO BE APPROVED
BY RESIDENT PROJECT ARCHITECT
5 INSTALL NEW PARTITION IN ORDER TO ENCLOSE EXISTING SPACE CONSISTENT
WITH ORIGINAL LAYOUT. NEW PARTITION SHALL BE FURNISHED AND FINISHED TO
MATCH EXISTING. TO BE APPROVED BY RESIDENT ENGINEER.
6 PLUMBING CHASE. GENERAL CONTRACTOR TO COORDINATE WITH PLUMBING
PLANS.
7 MECHANICAL CHASE. GENERAL CONTRACTOR TO COORDINATE WITH
MECHANICAL PLANS.
8 INSTALL SHAFT WALL AFTER TEMPORARY HYDRAULIC ELEVATOR REMOVAL IS
COMPLETED.
9 SINKS SHOWN FOR REFERENCE ONLY. TO BE PURCHASED AND INSTALLED BY
VCS.
WALL PROTECTION SHEET NOTES
1 SEE SHEET AS7-402R FOR TYPICAL WALL PROTECTION DETAILS.
2 CRASH RAIL, HANDRAIL, AND CHAIR RAIL TO START AND STOP 3" FROM CORNERS,
UNLESS OTHERWISE NOTED.
3 ALL OUTSIDE CORNERS TO RECEIVE CORNER GUARD, UNLESS OTHERWISE
NOTED.
4 ALL WALL PROTECTION EDGES TO RECEIVE CAULK TO ADJACENT SURFACES.
5 HANDRAIL TO STOP 2" FROM FIRE EXTINGUISHER CABINETS (FEC).
6 EXTEND ALL SHEET WALL PROTECTION TO ALL INSIDE AND OUTSIDE CORNERS IN
ENCLOSED ROOMS AND ALCOVES.
7 TYPICAL HEIGHT OF ALL WALL GUARDS TO BE 12" AFF ON CENTER.
8 TYPICAL HEIGHT OF ALL CHAIR RAILS AND HANDRAILS TO BE 32" AFF.
9 TYPICAL HEIGHT OF SHEET WALL PROTECTION TO BE 72".
NO REVISIONS DATE
SEE REVISED
DRAWING
AMENDMENT 9
(A-9003)
7/07/15
SUBMITTAL
08 71 00 - 01
2/27/17
RFI 0059
RFI 0186
File details come from the government source that posted it. Updated .