S02_Combined Attachments.pdf
PDF 13 MB Posted
- Attached to
- Z2DZ--631-24-002_Renovate B5 Linen Rooms
- Solicitation number
- 36C24124B0007
About this file
This solicitation is for renovating linen rooms at a Veterans Affairs medical center. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 1 is seeking offers for project Solicitation Number 36C24124B0007 to renovate B5 linen rooms. Offerors should provide construction and design services to update the linen rooms in accordance with the requirements in the 13MB attachment. Proposals are due by the date specified in the solicitation document. The award will be granted to the responsible offeror whose offer follows the solicitation instructions and is determined most advantageous to the government considering price and other factors.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| S04_Sign In Roster B5 Renovate Linen Rooms 631-24-002.pdf | ||
| 36C24124B0007 0005.docx | DOCX document | |
| 36C24124B0007 0004.docx | DOCX document | |
| 36C24124B0007 0003.docx | DOCX document | |
| Pictures.pdf | ||
| Combined Specs Renovate B5 Linen Rooms Project 631-24-002 V2.pdf | ||
| Drawings.pdf | ||
| 36C24124B0007 0002.docx | DOCX document | |
| 36C24124B0007 0001.docx | DOCX document | |
| S02_631-24-002 Drawings.pdf | ||
| S02 Combined Specs Renovate B5 Linen Rooms Project 631-24-002.pdf | ||
| 36C24124B0007_1.docx | DOCX document | |
| S02_WD_MA20230003_10.13.2023.pdf | ||
| S02_SOW_Renovate B5 Linen Rms.pdf |
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment A
PROJECT TITLE:
LOCATION:
CONTRACT NO.:
VA PROJECT NO.:
TO:
REQUEST SUBJECT:
Requested By:
Signed:
RESPONSE:
r
Edward P. Boland VA Medical Center VA Central Western Massachusetts Healthcare System
421 North Main Street
Leeds, MA 01053-9764
REQUEST FOR INFORMATION
NO.
DATE REQUIRED:
JOB:
CC:
Date:
This response does not constitute a change to the contract and is not an authorization to the contractor to proceed with any work that modifies the contract price or the time of performance. If the contractor believes that this response modifies any portion of the contract, the contractor shall make timely notice to the Contracting Officer and await the Contracting Officer's direction before proceeding with any work that the contractor believes is a modification to the contract.
r This response may constitute a change to the contract documents. Do not proceed with any work indicated in this response that changes the contract documents until directed in writing by the Contracting Officer.
Response By: Concur:
Signed:
Signed:
VA Project Manager
Date: Date:
Comments:
Complete Date and Time:
Location of Work:
HOT WORK PERMIT
THIS PERMIT IS REQUIRED FOR ANY TEMPORARY OPERATION INVOLVING OPEN FLAMES, HEAT, OR
SPARKS; SUCH AS" BRAZING, CUTTING, GRINDING OR WELDING (ANY TORCH USE).
INFORMATION
Safety personnel signing this permit must have valid 30 hour OSHA card and has verified, by his/her signature that all requirements located have been verified and completed.
REQUIRED PRECAUTIONS CHECKLIST
Available sprinklers, hose streams and
COR Final Check Name and Signature: Date:
Complete Date and Time:
Supervisor Name:
Supervisor's Signature:
Hot Work Technician VA Employee/Contractor Name:
Type of Hot Work to be Performed:
Start Date and Time:
Complete Date and Time:
HOT WORK PERMIT
THIS PERMIT IS REQUIRED FOR ANY TEMPORARY OPERATION INVOLVING OPEN FLAMES, HEAT, OR
SPARKS; SUCH AS" BRAZING, CUTTING, GRINDING OR WELDING (ANY TORCH USE).
INFORMATION REQUIRED PRECAUTIONS CHECKLIST
Available sprinklers, hose streams and extinguishers extinguishers are in service/operable? Safety personnel signing this permit must have valid 30 hour OSHA card and has verified, by his/her signature that all requirements located are in service/operable?
Hot work equipment inspected and in good repair?
Requirements within 35 ft. of work
Combustable floors wet down, covered with damp have been verified and completed.
Hot work equipment inspected and in good repair?
Hot Work Technician VA Employee/Contractor Name:
Requirements within 35 ft. of work
Combustable floors wet down, covered with damp sand or fire resistive sheets
Remove other combustables or cover with fire sand or fire resistive sheets
Remove other combustables or cover with fire blankets or curtains blankets or curtains
Wall and floor openings covered
Protect or shut down ducts that may carry sparks to Protect or shut down ducts that may carry sparks to
Location of Work: Wall and floor openings covered Work on walls, ceilings, or roofs combustable areas combustable areas
Type of Hot Work to be Performed: Work on walls, ceilings, or roofs
Construction is non-combustable Construction is non-combustable Combustables have been moved away
Work in enclosed equipment Enclosed permit quipment cleaned of all
Supervisor Name:
Supervisor's Signature:
Combustables have been moved away
Work in enclosed equipment Enclosed permit quipment cleaned of all combustables Containers purged of flammable liquids or vapors Start Date and Time: Containers purged of flammable liquids or vapors combustables Pressurized vessels/piping: isolated or vented Pressurized vessels/piping: isolated or vented Fire watch/monitoring of hot work area Complete Date and Time: Fire watch/monitoring of hot work area Fire watch shall be providedf 30 minutes after work Fire watch shall be providedf 30 minutes after work Fire watch shall be provided with extinguisher(s)
Fire watch is trained in the use of extinguishers and
Complete Date and Time: Fire watch shall be provided with extinguisher(s)
Fire watch is trained in the use of extinguishers and sounding alarm Fire watch may be required in adjoining areas to sounding alarm Complete Date and Time: Fire watch may be required in adjoining areas to Monitor hot work area for three hours after job is work work
Monitor hot work area for three hours after job is Safety Final Check and Approval Name and Signature: Date:
complete complete
Comments:
COR Final Check Name and Signature: Date:
Safety Final Check and Approval Name and Signature: Date:
VAMC Central Western Mass Environmental Health and Safety Leeds, MA 01053
Version 2/27/2018 Page 1 of 2
INTERM LIFE SAFETY MEASURES (ILSM) CHECKLIST
Project Name: __________________________ Project Number: ____________________
Project Start Date: ___________End Date: ___________ COR: __________________________
Yes No NA
Will any exits/means of egress be obstructed during construction such that alternate exits will have to be established?
If YES, then ensure that staff is notified/trained on alternate routes of exit and that proper signage is installed. Ensure that escape routes for construction workers are maintained at all times, and the means of exiting construction areas are inspected daily.
If NO, ensure that existing exit routes are free and unobstructed thru daily construction safety check.
Will access to emergency entrance be obstructed or will access by emergency forces (fire, police) be impaired?
If YES, ensure that alternate means of access or proper direction for emergency service personnel are provided
Will any fire alarm, detection or suppression system be impaired during this project?
If YES, provide temporary but equivalent system. Inspect temporary systems monthly.
If NO, ensure that they are in good working order.
Will temporary construction partitions be installed?
If YES, ensure that temporary construction partitions are smoke tight and built of noncombustible or limited combustible materials that will not contribute to the development or spread of fire. Ensure integrity of partitions during daily construction safety check.
Is additional fire-fighting equipment necessary?
If YES, ensure that they are provided and that staff are trained on their use.
Ensure that construction personnel are briefed on Medical Center’s “no smoking” policy and that “no smoking” signs are installed in and near the construction area.
Ensure that practices that reduce the building’s flammable and combustible fire load to the lowest feasible level are maintained and enforced (daily removal of debris, good housekeeping, and minimum storage of construction materials). This will be confirmed through daily construction checks and Medical Center staff's hazard surveillance.
If implementation of ILSMs is required, are 2 fire drills per shift per quarter required to be conducted?
If YES, ensure that fire dirll(s) are properly conducted and recorded/documented.
If implementation of ILSMs is required, then ensure that hazard surveillance of buildings, grounds, and equipment, with special attention to excavations, construction, areas, construction storage, and field offices, are conducted.
VAMC Central Western Mass Environmental Health and Safety Leeds, MA 01053
Version 2/27/2018 Page 2 of 2
Yes No NA
Are structural or compartmentalization features of fire safety impaired?
If YES, ensure that impacted staff are trained to compensate for impaired structural or compartmentalization features of fire safety.
Ensure that life safety building deficiencies, construction hazards, and ILSM for construction areas are announced in appropriate hospital communication channels.
General - Provide hospital wide safety education programs to promote awareness of life safety building deficiencies, construction hazards, and ILSM through the annual mandatory training.
COMMENTS:
COR Signature and Date Contractor Signature and Date
Safety Officer Signature and Date Fire Alarm Signature and Date
73 William Franks Drive
West Springfield. MA 01089 Telephone: (413) 781-0070 www: oneatlas.com
September 30, 2022
Mr. Daniel Witczak Acela Architects & Engineers 4969 Hamilton Blvd.
Allentown, PA 18106
RE: Asbestos & Lead Testing Report (Rev 1)
EHRM Infrastructure IT Upgrades Project Northampton Veteran’s Administration Medical Center VA Project #621-21-700 Leeds, Massachusetts
Dear Mr. Witczak:
Atlas Technical Consultants, LLC (ATLAS) was retained Acela Architects & Engineers to perform asbestos and lead paint testing as part of the forthcoming EHRM Infrastructure IT Upgrades Project at the Northampton Veterans Administration Medical Center located in Leeds, Massachusetts.
Specifically, ATLAS’s Scope of Work included:
1. Performance of an Asbestos Inspection for suspect asbestos-containing materials (ACM) to be disturbed as part of the forthcoming Building Foundation Repair Project to determine the type, location, condition, and quantity of ACM present.
2. Assessment as to the presence of lead-containing paint on architectural and structural components within areas to be renovated in the buildings.
3. Provide a written summary of on-site findings, including remediation requirements.
Limitations:
ATLAS’s survey only include the areas to be affected by the work at Buildings 1, 2, 3, 4, 5, 6, 7, 8, 9, 11, 12, 13, 14, 16, 22, 25 & 60, No other interior or exterior areas within each building were inspected by ATLAS.
ATC also utilized test results from Mabbett & Associates, Inc. “Asbestos-Containing Material & Lead Containing Paint Reports” for each building dated December 30, 2010 to confirm the presence of lead and/or asbestos-containing materials within areas subject to renovation work.
Outlined below is a summary of ATLAS’s findings:
I. ASBESTOS SURVEY
ATLAS's asbestos inspection included a visual assessment of accessible suspect asbestos-containing materials and subsequent bulk sampling and analysis was performed. The Asbestos inspection and bulk sampling was performed in accordance with the methods outlined in the U.S.
EPA guidance document titled, Guidance for Controlling Asbestos-Containing Materials in Buildings (Document No. 560/5-85/024). In addition, bulk sampling of asbestos was performed in accordance with 40 CFR Part 763, Asbestos Hazard Emergency Response Act (AHERA) requirements for number of samples and types of asbestos materials to be sampled. According to these requirements, materials are classified as either surfacing (e.g., ceiling plaster, wall plaster, spray-applied fireproofing), thermal system insulation (e.g., pipe insulation, pipe fitting insulation, boiler insulation), or miscellaneous materials (e.g., floor tile, ceiling tile, wallboard).
Asbestos & Lead Testing Report (Rev 1) EHRM Infrastructure IT Upgrades Project
Northampton VA Medical Center
The number of samples collected from each material varies based on the classification of the material and increases as the potential for a non-uniform mixture of asbestos in the material increases.
All bulk samples were analyzed for asbestos content using Polarized Light Microscopy (PLM) with Dispersion Staining EPA Method 600/R-93/116 per 40 CFR 763. To qualify as asbestos containing, the material must be determined to contain greater than one percent (>1%) asbestos from a homogeneous material area set of samples.
Consequently, according to the EPA/AHERA criteria, all bulk samples from a homogeneous area must be found to contain less than or equal to one percent (<1%) asbestos in order to be classified as non-asbestos-containing.
Findings:
Asbestos-containing materials were detected at the site buildings (excluding Building 14).
In accordance with Massachusetts Department of Environmental Protection (DEP) and
EPA’s National Emission Standards for Hazardous Air Pollutants (NESHAP) Regulations, materials found to be asbestos-containing must be abated prior to renovation/demolition activities.
All asbestos abatement work shall be performed by a Massachusetts licensed asbestos abatement contractor in accordance with local, state and federal regulations.
Refer to Attachment A for Table 1.0 that summarizes materials confirmed to be asbestos-containing at each building.
Refer to Attachment B for the Asbestos Bulk Sample Analysis Laboratory Reports.
Refer to Attachment D for a summary of materials found to be non-asbestos at each building.
II. LEAD-CONTAINING PAINT SURVEY
ATLAS performed a random lead paint inspection of painted, stained or varnished architectural components located at areas subject to renovation work. All testing was performed utilizing a portable X-Ray Fluorescent (XRF) Analyzer.
For reporting, the areas subject to renovation work were divided into “testing combinations”.
Testing combinations are defined as types of painted building components that appear uniform in paint color and architectural feature.
A Niton XL-309 spectrum analyzer lead detector, serial number U10314364LY was used for all on-site XRF testing. The instrument adjusts the length of each reading based upon the substrate, until a 95% confidence level is achieved. All personnel who operated the portable XRF analyzer were trained by the manufacturer in safety measures and testing protocols.
In accordance with the Occupational Safety and Health Administration (OSHA), any detectable result of lead constitutes the material to be considered lead-containing and subject to the compliance with OSHA 29 CFR 1926.62 Regulations during construction.
Asbestos & Lead Testing Report (Rev 1) EHRM Infrastructure IT Upgrades Project
Findings:
1. Lead-containing paint was detected at each building.
2. In general, the results are above the OSHA threshold of 0.0 which will require the Contractor to comply with OSHA 29 CFR 1926.62 Regulations with regards to protection of employees during renovation/demolition activities.
3. The buildings are not considered residences where children under the age of six (6) would reside, therefore abatement of lead-containing components will not be required as per Massachusetts Department of Public Health (DPH) "Child Lead Poisoning and Prevention Regulations.
All demolition debris shall be subject to federal Environmental Protection Agency (EPA) Resource Conservation and Recovery Act (RCRA) and Massachusetts Department of Environmental Protection (DEP) Regulations with regards to disposal.
Refer to Refer to Attachment C for Table 2.0 that summarizes the lead testing results for each building.
If you have any questions regarding this report or require additional information, please give Derrick Wissman a call directly at (413) 664-6687.
ATLAS TECHNICAL CONSULTANTS, LLC
Derrick Wissman Brian Williams Senior Project Manager Area Manager derrick.wissman@oneatlas.com brian.williams@oneatlas.com
Limitations - This survey was limited to accessible areas and no destructive investigation techniques were used to access hidden materials or locations. Because ATLAS could not access these areas during the survey, hazardous materials may exist at inaccessible areas of the buildings. Additionally, the passage of time may result in a change in the environmental characteristics at this site. This report does not warrant against future operations or conditions that could affect the conclusions made in this report. The results, findings and conclusions expressed in this report are based only on conditions that were observed during ATLAS’s site visit. ATLAS provided these services consistent with a level of skill ordinarily exercised by members of the profession currently practicing under similar conditions. This statement is in lieu of other statements either expressed or implied. This report is intended for the sole use of Acela Architect & Engineers. The scope of services performed in execution of this evaluation may not be appropriate to satisfy the needs of other users, and use or re-use of this document, the findings, conclusions, or recommendations is at the risk of said user.
ATTACHMENT A
Asbestos & Lead Testing Report (Rev 1) EHRM Infrastructure IT Upgrades Project
SUMMARY OF CONFIRMED ACM
(TABLE 1.0)
TABLE 1.0
SUMMARY OF ASBESTOS-CONTAINING MATERIALS TO BE ABATED
09-30-2022
# BUILDING LOCATION MATERIAL AMOUNT UNIT NOTES/COMMENTS
1 1 1071 Black Foundation Coat 120 SF
2 1 1071 Gold Mastic on Plaster Wall 620 SF
3 1 1071 Window Caulking and Glazing Compound 1 EA
4 1 2101 Window Caulking and Glazing Compound 1 EA
5 1 2111 Black Foundation Coat 200 SF
6 1 1262 Bath Pipe & Fitting Insulation 30 LF Inside wall chases
7 1 1270 IT/Bath Black Foundation Coat 355 SF
8 1 1270 IT/Bath Pipe & Fitting Insulation 30 LF Inside wall chases
9 1 1270 IT/Bath Window Caulking and Glazing Compound 1 EA
10 1 1-2WC-28 Black Foundation Coat 300 SF
11 1 2103 Bath Floor Tile & Mastic 85 SF Includes multiple layers of flooring as ACM
12 1 2103 Bath Pipe & Fitting Insulation 60 LF Inside wall chases
13 1 2111, 2-TE-2 Server Closet Floor Tile & Mastic 52 SF Includes multiple layers of flooring as ACM
14 1 B017 (Barber Shop/Storage B) Floor Tile & Mastic 180 SF
15 1 B017 (Barber Shop/Storage B) Pipe & Fitting Insulation 30 LF Inside wall chases
16 1 B017 (Barber Shop/Storage B) Window Caulking and Glazing Compound 1 EA
17 1 B111 Pipe & Fitting Insulation 2 LF
18 1 B241 Gold Mastic on Plaster Wall 20 SF
19 1 B241 Window Caulking and Glazing Compound 1 EA
20 2 208 Floor Tile & Mastic 1000 SF
21 2 208 Fire Door 1 EA
22 2 213 Floor Tile & Mastic 900 SF Entrance & under raised floor
23 2 213 Glue Daubs associated with 1'x1' Ceiling Tiles 900 SF Above suspended ceiling tiles
24 2 213 Fire Door 1 EA
25 2 Room 113 Pipe & Fitting Insulation 20 LF Inside wall chases
26 2 Room 114 Pipe & Fitting Insulation 20 LF Inside wall chases
27 2 Room 115A Custodial Window Caulking and Glazing Compound 1 EA
28 2 Room 115C IT Window Caulking and Glazing Compound 1 EA
29 2 Room 116 Bath Window Caulking and Glazing Compound 2 EA
30 3 121 Men's Bath Mastic Under Ceramic Threshold 3 SF
31 3 121 Men's Bath Pipe & Fitting Insulation 50 LF Inside wall chases
32 3 124 Custodial Pipe & Fitting Insulation 50 LF Inside wall chases
33 3 124 Custodial Mastic Under Ceramic Threshold 3 SF
34 3 Room 120 Pipe & Fitting Insulation 50 LF Inside wall chases
35 3 Room 120 Pipe & Fitting Insulation 20 LF
36 3 Room 120 Window Caulking and Glazing Compound 1 EA
EA = Each
LF = Linear Foot
SF = Square Foot
09-30-2022
# BUILDING LOCATION MATERIAL AMOUNT UNIT NOTES/COMMENTS
37 3 Room 122 IT Floor Tile & Mastic 36 SF
38 3 Room 123 IT Floor Tile & Mastic 36 SF
39 3 Room 218 Flooring Materials (All Layers) 100 SF Includes floor tile/mastic and ceramic tile/mastic
40 3 Room 218 Window Caulking and Glazing Compound 1 EA
41 3 Room 221 Glue Daubs on Ceiling 40 SF
42 3 Room 221 Floor Tile & Mastic 36 SF
43 3 Room 222 Mastic Under Ceramic Threshold 3 SF
44 3 Room 222 Pipe & Fitting Insulation 50 LF
45 4 233 Office & Common Area Window Caulking and Glazing Compound 1 EA
46 4 Room 104 Office Window Caulking and Glazing Compound 1 EA
47 5 Room 17 Fire Door 1 EA
48 5 Room 17 Black Mastic on Wood Ceiling 505 SF
49 5 Room 17 Pipe & Fitting Insulation 35 LF Inside wall chases
50 6 Room 116 Pipe & Fitting Insulation 6 LF Above plaster ceiling
51 6 Room 116 Sprinkler Pipe Thread 1 LF
52 6 Room 117 Sprinkler Pipe Thread 1 LF
53 6 Room 117 Window Caulking and Glazing Compound 1 EA
54 6 Room 213/217 Sprinkler Pipe Thread 1 LF
55 6 Room 213/217 Window Caulking and Glazing Compound 1 EA
56 6 Room 213/217 Floor Tile & Mastic 310 SF
57 9 Basement Room 2 Storage Asbestos Debris in Gravel 400 SF Includes removal of all debris and materials as ACM
58 9 Basement Sprinkler Pipe Thread 100 LF
59 11 1071 Pipe & Fitting Insulation 60 LF Inside wall chases
60 11 B017 (Barber Shop/Storage B) Glue Daubs on Ceiling 10 SF
61 11 Room 105 Pipe & Fitting Insulation 20 LF Inside wall chases
62 11 Room 105 Window Caulking and Glazing Compound 1 EA
63 11 Room 210 Glue Daubs associated with 1'x1' Ceiling Tiles 160 SF
64 11 Room 210 Window Caulking and Glazing Compound 2 EA
65 11 Room 210 Floor Tile & Mastic 160 SF
66 11 Room 210A Floor Tile & Mastic 96 SF
67 11 Room 210A Glue Daubs associated with 1'x1' Ceiling Tiles 96 SF
68 11 Room 210A Pipe & Fitting Insulation 50 LF Inside wall chases
69 11 Room 210A Window Caulking and Glazing Compound 1 EA
70 11 Room B6 Locker Window Caulking and Glazing Compound 1 EA
71 11 Room B7 Pipe & Fitting Insulation 20 LF Inside wall chases
72 11 Room B7 Window Caulking and Glazing Compound 1 EA
EA = Each
LF = Linear Foot
SF = Square Foot
ATTACHMENT A
VHANHMCarlaJ Highlight
VHANHMCarlaJ Oval
09-30-2022
# BUILDING LOCATION MATERIAL AMOUNT UNIT NOTES/COMMENTS
73 11 Room B8 Window Caulking and Glazing Compound 1 EA
74 11 Room 002A Window Caulking and Glazing Compound 2 EA
75 12 Basement B009B Pipe & Fitting Insulation 30 LF
76 12 Room 146 Floor Tile & Mastic 100 SF Under carpeting
77 12 Room 147 Carpet Adhesive 100 SF
78 12 Room 255 Flooring Materials (All Layers) 180 SF Includes multiple layers of flooring as ACM
79 12 Room 255 Window Caulking and Glazing Compound 2 EA
80 12 Steam Tunnel Pipe Fittings on Fiberglass Lines 5 EA
81 13 Break Room Flex Connector 1 EA
82 13 Break Room Window Caulking and Glazing Compound 1 EA
83 16 B101/Renovation Area Sprinkler Pipe Thread 2 LF
84 16 Basement Bathroom Mirror Adhesive 1 EA
85 16 Basement Bathroom Sprinkler Pipe Thread 1 LF
86 16 Basement Bathroom Window Caulking and Glazing Compound 2 EA
87 22 Kitchen Flooring Materials (All Layers) 200 SF
88 22 Kitchen Cove Base and Mastic 10 LF At cabinet being removed
89 22 Kitchen Backsplash 15 SF At cabinet being removed
90 22 Kitchen Pipe & Fitting Insulation 20 LF Inside wall chases
91 22 Vestibule Flooring Materials (All Layers) 80 SF
92 22 Office Flooring Materials (All Layers) 180 SF
93 22 Laboratory - 1st Floor Flooring Materials (All Layers) 40 SF
94 22 Bathroom - 1st Floor Ceramic Flooring/Adhesive 15 SF
95 22 Bathroom 204 - 2nd Floor Flooring Materials (All Layers) 35 SF Includes ceramic tile/adhesive underneath
96 22 Exterior Roofing Material 760 SF
97 22 Exterior Window Caulking and Glazing Compound 13 EA Vestibule & Office Windows
98 22 Basement Pipe & Fitting Insulation 260 LF Includes all remaining ACM pipe in Basement
99 22 Basement Window Caulking and Glazing Compound 4 EA At Storage Room and Carport
100 25 Room 02 Pipe & Fitting Insulation 30 LF
101 25 Room 02 Sprinkler Pipe Thread 3 LF
102 25 Room 107 Pipe & Fitting Insulation 58 LF Inside wall chases
103 25 Room 107 Window Caulking and Glazing Compound 1 EA
104 25 Room 108 Pipe & Fitting Insulation 58 LF Inside wall chases
105 25 Room 108 Window Caulking and Glazing Compound 1 EA
106 25 Room 208 Window Caulking and Glazing Compound 1 EA
107 25 Room 209 Custodial Floor Tile & Mastic 20 SF
108 25 Room 210 Floor Tile & Mastic 25 SF
EA = Each
LF = Linear Foot
09-30-2022
# BUILDING LOCATION MATERIAL AMOUNT UNIT NOTES/COMMENTS
109 25 Room 210 Restroom Window Caulking and Glazing Compound 1 EA
110 25 Room 210 Restroom Pipe & Fitting Insulation 50 LF Inside wall chases
111 26 Basement IT Closet Window Caulking and Glazing Compound 1 EA
112 60 Exterior Window Caulking and Glazing Compound 2 EA
EA = Each
LF = Linear Foot
ATTACHMENT B
Asbestos & Lead Testing Report (Rev 1) EHRM Infrastructure IT Upgrades Project
ATTACHMENT B
PLM BULK ASBESTOS LABORATORY REPORTS
EMSL Analytical, Inc.
307 West 38th Street New York, NY 10018
Tel/Fax: (212) 290-0051 / (212) 290-0058 http://www.EMSL.com / manhattanlab@emsl.com
032204821EMSL Order:
ATC62Customer ID:
11-81-0030Customer PO:
Project ID:
Attention: Phone:Derrick Wissman (413) 781-0070
Fax:Atlas Technical (413) 781-3734
Received Date:73 William Franks Drive 03/31/2022 10:12 AM
Analysis Date:West Springfield, MA 01089 04/07/2022
Collected Date: 03/30/2022
Project: 183DW22028/ Northampton VA Building 1/ Leeds, MA
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using
Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous % Type
Non-Asbestos Asbestos
VA1-06A
032204821-0001
Room 1071 - Joint
Compound
White
Fibrous
Homogeneous
None DetectedCellulose
Glass
5%
3%
10%
45%
7%
15%
15.0%
Quartz
Ca Carbonate
Mica
Perlite
Non-fibrous (Other)
VA1-06B
032204821-0002
Room 2103 Bath - Joint
Compound
White
Non-Fibrous
Homogeneous
None Detected35%
50%
5%
10.0%
Ca Carbonate
Gypsum
Mica
Non-fibrous (Other)
VA1-07A
032204821-0003
Room 1071 - Gold
Mastic On Plaster Wall
Brown
Non-Fibrous
Homogeneous
Chrysotile15%5%
10%
70.0%
Quartz
Ca Carbonate
Non-fibrous (Other)
VA1-07B
032204821-0004
Room 1071 - Gold
Mastic On Plaster Wall
Positive Stop
(Not Analyzed)
VA1-08A
032204821-0005
Room 1071 - 4" Tan
Cove Base
Tan
Non-Fibrous
Homogeneous
None Detected7%
65%
3%
25.0%
Quartz
Ca Carbonate
Mica
Non-fibrous (Other)
VA1-08B
032204821-0006
Room 1071 - 4" Tan
Cove Base
Tan
Non-Fibrous
Homogeneous
None Detected15%
60%
5%
20.0%
Quartz
Ca Carbonate
Mica
Non-fibrous (Other)
VA1-08C
032204821-0007
2nd Floor 2-TE-2 IT
Closet - 4" Tan Cove
Base
Tan
Non-Fibrous
Homogeneous
None Detected40%
60.0%
Ca Carbonate
Non-fibrous (Other)
VA1-09A
032204821-0008
Room 1071 - Mastic
Under 4" Tan Cove
Base
Brown
Non-Fibrous
Homogeneous
None Detected10%
25%
5%
60.0%
Quartz
Ca Carbonate
Mica
Non-fibrous (Other)
VA1-09B
032204821-0009
Room 1071 - Mastic
Under 4" Tan Cove
Base
Brown
Non-Fibrous
Homogeneous
None Detected7%
30%
3%
60.0%
Quartz
Ca Carbonate
Mica
Non-fibrous (Other)
EMSL maintains liability limited to cost of analysis . Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations . The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA
600/M4-82-020 “Interim Method”) but augmented with procedures outlined in the 1993 (”final”) version of the method. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government . Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample.
Estimation of uncertainty is available on request.
Samples analyzed by EMSL Analytical, Inc. New York, NY AIHA-LAP, LLC--IHLAP Accredited #102581, NVLAP Lab Code 101048-9, NJ NY022, CT PH-0170, MA AA000170
Initial report from: 04/07/2022 18:02:56
ASB_PLMwSigs_0007_0001 Printed:4/7/2022 7:54:25PM Page 1 of 6
Tel/Fax: (212) 290-0051 / (212) 290-0058 http://www.EMSL.com / manhattanlab@emsl.com
032204821EMSL Order:
ATC62Customer ID:
11-81-0030Customer PO:
Project ID:
Attention: Phone:Derrick Wissman (413) 781-0070
Fax:Atlas Technical (413) 781-3734
Received Date:73 William Franks Drive 03/31/2022 10:12 AM
Analysis Date:West Springfield, MA 01089 04/07/2022
Collected Date: 03/30/2022
Project: 183DW22028/ Northampton VA Building 1/ Leeds, MA
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using
Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous % Type
Non-Asbestos Asbestos
VA1-09C
032204821-0010
2nd Floor 2-TE-2 IT
Closet - Mastic Under
4" Tan Cove Base
Brown
Non-Fibrous
Homogeneous
None Detected100.0% Non-fibrous (Other)
VA1-10A
032204821-0011
Room 1071 - Mastic
Under Self Adhesive
Carpet Tile
Various
Non-Fibrous
Homogeneous
None DetectedCellulose
Synthetic
3%
2%
25%
15%
5%
50.0%
Quartz
Ca Carbonate
Mica
Non-fibrous (Other)
VA1-10B
032204821-0012
Room 2101 - Mastic
Under Self Adhesive
Carpet Tile
Yellow
Non-Fibrous
Homogeneous
None Detected25%
75.0%
Quartz
Non-fibrous (Other)
VA1-13A
032204821-0013
1262 Bath - 1'x1' Gray
Ceramic Floor Tile
Grout
Gray
Non-Fibrous
Homogeneous
None Detected20%
50%
5%
25.0%
Quartz
Ca Carbonate
Mica
Non-fibrous (Other)
VA1-13B
032204821-0014
1262 Bath - 1'x1' Gray
Ceramic Floor Tile
Grout
Gray
Non-Fibrous
Homogeneous
None Detected65%
20%
15.0%
Quartz
Ca Carbonate
Non-fibrous (Other)
VA1-14A
032204821-0015
1262 Bath - 1'x1' Gray
Ceramic Floor Tile
Mastic
Yellow
Non-Fibrous
Homogeneous
None Detected7%
15%
3%
75.0%
Quartz
Ca Carbonate
Mica
Non-fibrous (Other)
VA1-14B
032204821-0016
1262 Bath - 1'x1' Gray
Ceramic Floor Tile
Mastic
Yellow
Non-Fibrous
Homogeneous
None Detected20%
80.0%
Ca Carbonate
Non-fibrous (Other)
VA1-16A
032204821-0017
1270 Bath - Black
Foundation Coat
Black
Non-Fibrous
Homogeneous
Chrysotile5%10%
15%
70.0%
Quartz
Ca Carbonate
Non-fibrous (Other)
VA1-16B
032204821-0018
1270 Bath - Black
Foundation Coat
Positive Stop
(Not Analyzed)
EMSL maintains liability limited to cost of analysis . Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations . The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA
600/M4-82-020 “Interim Method”) but augmented with procedures outlined in the 1993 (”final”) version of the method. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government . Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample.
Estimation of uncertainty is available on request.
Samples analyzed by EMSL Analytical, Inc. New York, NY AIHA-LAP, LLC--IHLAP Accredited #102581, NVLAP Lab Code 101048-9, NJ NY022, CT PH-0170, MA AA000170
ASB_PLMwSigs_0007_0001 Printed:4/7/2022 7:54:25PM Page 2 of 6
Tel/Fax: (212) 290-0051 / (212) 290-0058 http://www.EMSL.com / manhattanlab@emsl.com
032204821EMSL Order:
ATC62Customer ID:
11-81-0030Customer PO:
Project ID:
Attention: Phone:Derrick Wissman (413) 781-0070
Fax:Atlas Technical (413) 781-3734
Received Date:73 William Franks Drive 03/31/2022 10:12 AM
Analysis Date:West Springfield, MA 01089 04/07/2022
Collected Date: 03/30/2022
Project: 183DW22028/ Northampton VA Building 1/ Leeds, MA
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using
Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous % Type
Non-Asbestos Asbestos
VA1-17A
032204821-0019
1270 Bath - 4"x4"
Whiter Ceramic Wall
Tile Grout
Gray/White
Non-Fibrous
Homogeneous
None Detected3%
45%
2%
20%
30.0%
Quartz
Ca Carbonate
Mica
Perlite
Non-fibrous (Other)
VA1-17B
032204821-0020
1270 Bath - 4"x4"
Whiter Ceramic Wall
Tile Grout
White
Non-Fibrous
Homogeneous
None Detected70%
8%
22.0%
Ca Carbonate
Gypsum
Non-fibrous (Other)
VA1-18A
032204821-0021
1270 Bath - 4"x4"
Whiter Ceramic Wall
Tile Mastic
Gray
Non-Fibrous
Homogeneous
None Detected20%
45%
5%
30.0%
Quartz
Ca Carbonate
Mica
Non-fibrous (Other)
VA1-18B
032204821-0022
1270 Bath - 4"x4"
Whiter Ceramic Wall
Tile Mastic
Gray
Non-Fibrous
Homogeneous
None Detected50%
35%
8%
7.0%
Quartz
Ca Carbonate
Mica
Non-fibrous (Other) Sample material appears to be Ceramic Wall Tile Mortar.
VA1-19A
032204821-0023
1270 Bath - Brown
Ceramic Floor Tile
Grout
Gray
Non-Fibrous
Homogeneous
None Detected35%
40%
5%
20.0%
Quartz
Ca Carbonate
Mica
Non-fibrous (Other)
VA1-19B
032204821-0024
1270 Bath - Brown
Ceramic Floor Tile
Grout
Gray
Non-Fibrous
Homogeneous
None Detected40%
45%
5%
10.0%
Quartz
Ca Carbonate
Mica
Non-fibrous (Other)
VA1-20A
032204821-0025
1270 Bath - Brown
Ceramic Floor Tile
Mastic
Gray
Non-Fibrous
Homogeneous
None Detected25%
45%
5%
10%
15.0%
Quartz
Ca Carbonate
Mica
Perlite
Non-fibrous (Other)
VA1-20B
032204821-0026
1270 Bath - Brown
Ceramic Floor Tile
Mastic
Insufficient
Material
Sample bag contains Brown Ceramic Floor Tile only.
EMSL maintains liability limited to cost of analysis . Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations . The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA
600/M4-82-020 “Interim Method”) but augmented with procedures outlined in the 1993 (”final”) version of the method. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government . Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample.
Estimation of uncertainty is available on request.
Samples analyzed by EMSL Analytical, Inc. New York, NY AIHA-LAP, LLC--IHLAP Accredited #102581, NVLAP Lab Code 101048-9, NJ NY022, CT PH-0170, MA AA000170
ASB_PLMwSigs_0007_0001 Printed:4/7/2022 7:54:25PM Page 3 of 6
Tel/Fax: (212) 290-0051 / (212) 290-0058 http://www.EMSL.com / manhattanlab@emsl.com
032204821EMSL Order:
ATC62Customer ID:
11-81-0030Customer PO:
Project ID:
Attention: Phone:Derrick Wissman (413) 781-0070
Fax:Atlas Technical (413) 781-3734
Received Date:73 William Franks Drive 03/31/2022 10:12 AM
Analysis Date:West Springfield, MA 01089 04/07/2022
Collected Date: 03/30/2022
Project: 183DW22028/ Northampton VA Building 1/ Leeds, MA
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using
Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous % Type
Non-Asbestos Asbestos
VA1-23A
032204821-0027
B017 Barbershop -
1'x1' White W/Black
Specks Floor Tile
Tan
Non-Fibrous
Homogeneous
Chrysotile3%10%
55%
32.0%
Quartz
Ca Carbonate
Non-fibrous (Other)
VA1-23B
032204821-0028
B017 Barbershop -
1'x1' White W/Black
Specks Floor Tile
Positive Stop
(Not Analyzed)
VA1-24A
032204821-0029
B017 Barbershop -
Mastic 1'x1' White
W/Black Specks Floor
Tile
Black
Non-Fibrous
Homogeneous
None DetectedCellulose5% 7%
15%
3%
70.0%
Quartz
Ca Carbonate
Mica
Non-fibrous (Other)
VA1-24B
032204821-0030
B017 Barbershop -
Mastic 1'x1' White
W/Black Specks Floor
Tile
Black
Non-Fibrous
Homogeneous
None Detected10%
90.0%
Ca Carbonate
Non-fibrous (Other)
VA1-25A
032204821-0031
B017 Barbershop - 4"
Old Black Cove Base
Brown/Black
Non-Fibrous
Homogeneous
None DetectedCellulose60% 5%
10%
25.0%
Quartz
Ca Carbonate
Non-fibrous (Other)
VA1-25B
032204821-0032
B017 Barbershop - 4"
Old Black Cove Base
Brown/Black
Fibrous
Homogeneous
None DetectedCellulose85% 15.0% Non-fibrous (Other)
VA1-26A
032204821-0033
B017 Barbershop -
Mastic Under 4" Old
Black Cove Base
Brown
Non-Fibrous
Homogeneous
None DetectedCellulose80% 3%
5%
2%
10.0%
Quartz
Ca Carbonate
Mica
Non-fibrous (Other) Inseparable paint / coating layer included in analysis.
VA1-26B
032204821-0034
B017 Barbershop -
Mastic Under 4" Old
Black Cove Base
Yellow
Non-Fibrous
Homogeneous
None DetectedCellulose5% 15%
80.0%
Ca Carbonate
Non-fibrous (Other)
VA1-27A
032204821-0035
Room 2103 Bath - 1'x1'
Gray W/White Specks
Floor Tile
Tan
Non-Fibrous
Homogeneous
None Detected10%
45%
45.0%
Quartz
Ca Carbonate
Non-fibrous (Other)
EMSL maintains liability limited to cost of analysis . Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations . The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA
600/M4-82-020 “Interim Method”) but augmented with procedures outlined in the 1993 (”final”) version of the method. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government . Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample.
Estimation of uncertainty is available on request.
Samples analyzed by EMSL Analytical, Inc. New York, NY AIHA-LAP, LLC--IHLAP Accredited #102581, NVLAP Lab Code 101048-9, NJ NY022, CT PH-0170, MA AA000170
ASB_PLMwSigs_0007_0001 Printed:4/7/2022 7:54:25PM Page 4 of 6
Tel/Fax: (212) 290-0051 / (212) 290-0058 http://www.EMSL.com / manhattanlab@emsl.com
032204821EMSL Order:
ATC62Customer ID:
11-81-0030Customer PO:
Project ID:
Attention: Phone:Derrick Wissman (413) 781-0070
Fax:Atlas Technical (413) 781-3734
Received Date:73 William Franks Drive 03/31/2022 10:12 AM
Analysis Date:West Springfield, MA 01089 04/07/2022
Collected Date: 03/30/2022
Project: 183DW22028/ Northampton VA Building 1/ Leeds, MA
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using
Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous % Type
Non-Asbestos Asbestos
VA1-27B
032204821-0036
2nd Floor 2-TE-2 IT
Closet - 1'x1' Gray
W/White Specks Floor
Tile
Insufficient
Material
Sample bag is empty.
VA1-28A
032204821-0037
Room 2103 Bath -
Mastic 1'x1' Gray
W/White Specks Floor
Tile
Black
Non-Fibrous
Homogeneous
Chrysotile10%5%
25%
60.0%
Quartz
Ca Carbonate
Non-fibrous (Other)
VA1-28B
032204821-0038
2nd Floor 2-TE-2 IT
Closet - Mastic 1'x1'
Gray W/White Specks
Floor Tile
Positive Stop
(Not Analyzed)
VA1-29A
032204821-0039
Room 2103 Bath - 6"
Tan Cove Base
Beige
Non-Fibrous
Homogeneous
None Detected10%
70%
20.0%
Quartz
Ca Carbonate
Non-fibrous (Other)
VA1-29B
032204821-0040
Room 2101 - 6" Tan
Cove Base
Tan
Non-Fibrous
Homogeneous
None Detected40%
10%
50.0%
Ca Carbonate
Gypsum
Non-fibrous (Other)
VA1-30A
032204821-0041
Room 2103 Bath -
Mastic Under 6" Tan
Cove Base
Brown
Non-Fibrous
Homogeneous
None Detected5%
10%
85.0%
Quartz
Ca Carbonate
Non-fibrous (Other)
VA1-30B
032204821-0042
Room 2101 - Mastic
Under 6" Tan Cove
Base
Brown
Non-Fibrous
Homogeneous
None Detected20%
80.0%
Ca Carbonate
Non-fibrous (Other)
VA1-33A
032204821-0043
Room 2101 - 2'x2'
Smooth Ceiling Tile
Brown
Fibrous
Homogeneous
None DetectedCellulose
Glass
35%
30%
5%
15%
15.0%
Quartz
Perlite
Non-fibrous (Other)
EMSL maintains liability limited to cost of analysis . Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations . The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA
600/M4-82-020 “Interim Method”) but augmented with procedures outlined in the 1993 (”final”) version of the method. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government . Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample.
Estimation of uncertainty is available on request.
Samples analyzed by EMSL Analytical, Inc. New York, NY AIHA-LAP, LLC--IHLAP Accredited #102581, NVLAP Lab Code 101048-9, NJ NY022, CT PH-0170, MA AA000170
ASB_PLMwSigs_0007_0001 Printed:4/7/2022 7:54:25PM Page 5 of 6
Tel/Fax: (212) 290-0051 / (212) 290-0058 http://www.EMSL.com / manhattanlab@emsl.com
032204821EMSL Order:
ATC62Customer ID:
11-81-0030Customer PO:
Project ID:
Attention: Phone:Derrick Wissman (413) 781-0070
Fax:Atlas Technical (413) 781-3734
Received Date:73 William Franks Drive 03/31/2022 10:12 AM
Analysis Date:West Springfield, MA 01089 04/07/2022
Collected Date: 03/30/2022
Project: 183DW22028/ Northampton VA Building 1/ Leeds, MA
The samples in this report were submitted to EMSL for analysis by Asbestos Analysis of Bulk materials via
EPA/600 (0513) Method using Polarized Light Microscopy. The reference number for these samples is the
EMSL Order ID above. Please use this reference number when calling about these samples.
Report Comments:
Sample Receipt Date:
Analysis Completed Date:
Sample Receipt Time:
Analysis Completed Time:
03/31/2022 10:12 AM
04/07/2022 5:17 PM
Analyst(s):
Christopher Cernansky PLM (14) Kerrie Gibson PLM (23)
Samples Reviewed and approved by:
Charles Johnson, Asbestos Laboratory Manager or other approved signatory
EMSL maintains liability limited to cost of analysis . Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations . The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA
600/M4-82-020 “Interim Method”) but augmented with procedures outlined in the 1993 (”final”) version of the method. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government . Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample.
Estimation of uncertainty is available on request.
Samples analyzed by EMSL Analytical, Inc. New York, NY AIHA-LAP, LLC--IHLAP Accredited #102581, NVLAP Lab Code 101048-9, NJ NY022, CT PH-0170, MA AA000170
ASB_PLMwSigs_0007_0001 Printed:4/7/2022 7:54:25PM Page 6 of 6
OrderID: 032204821
Tel/Fax: (212) 290-0051 / (212) 290-0058 http://www.EMSL.com / manhattanlab@emsl.com
032215821EMSL Order:
ATC62Customer ID:
11-81-0030Customer PO:
Project ID:
Attention: Phone:Edward Kolodziej (413) 426-6819
Fax:Atlas Technical (413) 781-3734
Received Date:73 William Franks Drive 09/16/2022 12:25 PM
Analysis Date:West Springfield, MA 01089 09/20/2022
Collected Date: 09/09/2022
Project: ACELA Architects/ VA Medical Center, Leeds, MA - Building 1
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using
Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous % Type
Non-Asbestos Asbestos
VA1-01A
032215821-0001
2238 - Black Felt
Behind Concrete and
Terracotta
Black
Non-Fibrous
Homogeneous
None DetectedGlass35% 65.0% Non-fibrous (Other)
Inseparable
VA1-01B
032215821-0002
2238 - Black Felt
Behind Concrete and
Terracotta
Black
Fibrous
Homogeneous
None DetectedCellulose15% 85.0% Non-fibrous (Other)
VA1-02A
032215821-0003
2238 - Sprinkler Pipe
Thread
Tan
Non-Fibrous
Homogeneous
None Detected100.0% Non-fibrous (Other)
VA1-02B
032215821-0004
2233 - Sprinkler Pipe
Thread
Tan
Non-Fibrous
Homogeneous
None Detected100.0% Non-fibrous (Other)
VA1-02C
032215821-0005
2WA-21 - Sprinkler
Pipe Thread
Yellow
Non-Fibrous
Homogeneous
None Detected20%
80.0%
Ca Carbonate
Non-fibrous (Other)
VA1-02D
032215821-0006
2WA-18 - Sprinkler
Pipe Thread
Tan
Non-Fibrous
Homogeneous
None Detected100.0% Non-fibrous (Other)
VA1-02E
032215821-0007
2WC-38 - Sprinkler
Pipe Thread
Gray
Non-Fibrous
Homogeneous
None Detected10%
90.0%
Ca Carbonate
Non-fibrous (Other)
VA1-02F
032215821-0008
2103 - Sprinkler Pipe
Thread
Tan/White
Non-Fibrous
Homogeneous
None Detected5%
95.0%
Ca Carbonate
Non-fibrous (Other)
VA1-03A
032215821-0009
2103 - Floor Tile under
1'X1' Gray Mottled
Floor Tile
Gray
Non-Fibrous
Homogeneous
Chrysotile2%40%
58.0%
Ca Carbonate
Non-fibrous (Other)
EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA
600/M4-82-020 “Interim Method”) but augmented with procedures outlined in the 1993 (”final”) version of the method. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample.
Estimation of uncertainty is available on request.
Samples analyzed by EMSL Analytical, Inc. New York, NY AIHA-LAP, LLC--IHLAP Accredited #102581, NVLAP Lab Code 101048-9, NJ NY022, CT PH-0170, MA AA000170
Initial report from: 09/20/2022 16:21:32
ASB_PLMwSigs_0007_0001 Printed:9/20/2022 4:21:34PM Page 1 of 4
Tel/Fax: (212) 290-0051 / (212) 290-0058 http://www.EMSL.com / manhattanlab@emsl.com
032215821EMSL Order:
ATC62Customer ID:
11-81-0030Customer PO:
Project ID:
Attention: Phone:Edward Kolodziej (413) 426-6819
Fax:Atlas Technical (413) 781-3734
Received Date:73 William Franks Drive 09/16/2022 12:25 PM
Analysis Date:West Springfield, MA 01089 09/20/2022
Collected Date: 09/09/2022
Project: ACELA Architects/ VA Medical Center, Leeds, MA - Building 1
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using
Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous % Type
Non-Asbestos Asbestos
VA1-03B
032215821-0010
2103 - Floor Tile under
1'X1' Gray Mottled
Floor Tile
Positive Stop
(Not Analyzed)
VA1-04A
032215821-0011
2103 - Floor Tile Mastic
(Associated with
Sample 03A)
Black
Non-Fibrous
Homogeneous
Chrysotile5%95.0% Non-fibrous (Other)
VA1-04B
032215821-0012
2103 - Floor Tile Mastic
(Associated with
Sample 03A)
Positive Stop
(Not Analyzed)
VA1-05A
032215821-0013
2103 - Gray Floor
Leveler
Gray
Non-Fibrous
Homogeneous
None Detected45%
15%
3%
37.0%
Quartz
Ca Carbonate
Mica
Non-fibrous (Other)
VA1-05B
032215821-0014
2103 - Gray Floor
Leveler
Brown/Black
Non-Fibrous
Homogeneous
None Detected40%
20%
40.0%
Quartz
Ca Carbonate
Non-fibrous (Other)
VA1-06A
032215821-0015
2103 - Concrete Floor Gray
Non-Fibrous
Homogeneous
None Detected50%
20%
3%
27.0%
Quartz
Ca Carbonate
Mica
Non-fibrous (Other)
VA1-06B
032215821-0016
2103 - Concrete Floor Gray
Non-Fibrous
Homogeneous
None Detected45%
20%
4%
31.0%
Quartz
Ca Carbonate
Mica
Non-fibrous (Other)
VA1-07A
032215821-0017
B111 - Push Pin
Adhesive
Black
Non-Fibrous
Homogeneous
None Detected10%
90.0%
Ca Carbonate
Non-fibrous (Other)
VA1-07B
032215821-0018
B111 - Push Pin
Adhesive
Tan/White
Non-Fibrous
Homogeneous
None Detected2%
15%
83.0%
Quartz
Ca Carbonate
Non-fibrous (Other)
Inseparable paint / coating layer included in analysis
EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA
600/M4-82-020 “Interim Method”) but augmented with procedures outlined in the 1993 (”final”) version of the method. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample.
Estimation of uncertainty is available on request.
Samples analyzed by EMSL Analytical, Inc. New York, NY AIHA-LAP, LLC--IHLAP Accredited #102581, NVLAP Lab Code 101048-9, NJ NY022, CT PH-0170, MA AA000170
ASB_PLMwSigs…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .