This document contains electrical drawings and specifications for infrastructure upgrades at a Department of Veterans Affairs medical center. The drawings show the location of existing electrical panels, proposed work including a new electrical room and panel, and details of the telecommunications room upgrades. Specifications include lighting fixture schedules and notes. Also included is information for a related federal contract opportunity to renovate linen rooms in Building 5, with a solicitation number of 36C24124B0007 and an award date after June 2023. The work involves electrical system upgrades and renovations to support improved healthcare technology and operations at the Central Western Massachusetts VA medical center.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| S04_Sign In Roster B5 Renovate Linen Rooms 631-24-002.pdf | ||
| 36C24124B0007 0005.docx | DOCX document | |
| 36C24124B0007 0004.docx | DOCX document | |
| 36C24124B0007 0003.docx | DOCX document | |
| Pictures.pdf | ||
| Combined Specs Renovate B5 Linen Rooms Project 631-24-002 V2.pdf | ||
| 36C24124B0007 0002.docx | DOCX document | |
| 36C24124B0007 0001.docx | DOCX document | |
| S02_631-24-002 Drawings.pdf | ||
| S02 Combined Specs Renovate B5 Linen Rooms Project 631-24-002.pdf | ||
| 36C24124B0007_1.docx | DOCX document | |
| S02_Combined Attachments.pdf | ||
| S02_WD_MA20230003_10.13.2023.pdf | ||
| S02_SOW_Renovate B5 Linen Rms.pdf |
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
05-EP101
BUILDING NO. 5 - BASEMENT LEVEL
ELECTRICAL PLAN 05
W.H.H. E.J.D.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
CONSTRUCTION
DOCUMENTS
MAY 30, 2023
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
ELECTRICAL DISTRIBUTION
SYSTEM UPGRADE - PHASE 2
VA CWM
631-18-003
Project Director
MAY 30, 2023Revisions: Date:
© Copyright 2020 DuBois & King Inc.
85 MAIN STREET
SPRINGFIELD, VT 05156
TEL: (802) 591-4326
FAX: (866) 783-7101
www.dubois-king.com
I:\ 5\
V
AM
C
E le c D is t P ha se
3\ D ra w in gs
\E le ct ric al \0
5-
EP
BU
IL
D
IN
G N
O . 5
BA
SE
M
EN
T
LE
VE
L
EL
EC
TR
IC
AL
P
LA
N .d w g
1/
2/
4:
:3
PM
LIGHTING FIXTURE SCHEDULE
MARK MANUFACTURER USAGE CATALOG NUMBER COLOR LUMENS LAMP DIST. VOLTAGE CCT CRI WATTS NOTES
A LITHONIA OR APPROVED EQUAL STRIP LIGHT FOR ELECTRIC ROOMS ZL1D L48 5000LM FST MVOLT 40K 80CRI WH WHITE 5,000 LED WIDE MVOLT 4000K 80 41 MTD IN EXIST. LOCATION B LITHONIA OR APPROVED EQUAL WALL PACK - EXTERIOR BUILDING WDGE2 LED-P4-30K-80CRI-VW-MVOLT-SRM-PE-DBLXD BLACK 4,357 LED WIDE MVOLT 3000K 80 35 WITH PBBW BACK BOX
C LITHONIA OR APPROVED EQUAL WALL PACK - EXTERIOR BUILDING WDGE1 LED-P2-30K-80CRI-VF-MVOLT-SRM-PE-DBLXD BLACK 1,872 LED FORWARD MVOLT 3000K 80 15 WITH PBBW BACK BOX
EX COOPER OR APPROVED EQUAL EXIT SIGNS APCH7R WHITE - LED MVOLT N/A N/A 1.3 MOUNTED ABOVE DOOR RM COOPER OR APPROVED EQUAL REMOTE HEADS APWR2 WHITE - LED MVOLT N/A N/A 0.78 MOUNTED ABOVE DOOR
NOTES:
1. FIXTURE TYPES LISTED INDICATE LED TYPE, COLOR TEMPERATURE, WATTAGE, MINIMUM LUMENS, QUALITY, MOUNTING STYLE, LED, AND DOES NOT LIMIT SELECTION TO THE LISTED MANUFACTURERS.
'OR EQUAL' (EQUIVALENT) FIXTURES MAY BE SUBMITTED FOR APPROVAL.
2. ENSURE THAT LED LIGHTING FIXTURES INSTALLED ARE LISTED ON THE ENERGY STAR (www.energystar.gov) APPROVED PRODUCTS LIST TO ACQUIRE A REBATE INCENTIVE W/ NATIONAL GRID'S
PROGRAMS.
AutoCAD SHX Text
DN
AutoCAD SHX Text
UP
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
EXISTING NORMAL POWER BREAKER
AutoCAD SHX Text
EXISTING EMERGENCY POWER BREAKER
AutoCAD SHX Text
EXISTING EEXISTING 5-MDP-2
AutoCAD SHX Text
EXSITING ATS#4 TO BE REMOVED. PROVIDE NEW ATS SWITCH
AutoCAD SHX Text
EXISTING 5-MDP
AutoCAD SHX Text
EXISTING 5-EDP
AutoCAD SHX Text
EXISTING 5-MDP-3
AutoCAD SHX Text
EXISTING 5-B11
AutoCAD SHX Text
EXISTING 5-B2
AutoCAD SHX Text
EXISTING 5-B10
AutoCAD SHX Text
NEW E5-B2LS
AutoCAD SHX Text
EXISTING 5-B9
AutoCAD SHX Text
EXISTING 5-B8
AutoCAD SHX Text
EXISTING 5-B7
AutoCAD SHX Text
EXISTING 5-B6
AutoCAD SHX Text
EXISTING 5-B5
AutoCAD SHX Text
EXISTING 5-B4
AutoCAD SHX Text
EXISTING 5-B3
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EL
AutoCAD SHX Text
AutoCAD SHX Text 23A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
HK
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ENG
AutoCAD SHX Text
ENG
AutoCAD SHX Text
FC
AutoCAD SHX Text
EXISTING E5-LS
AutoCAD SHX Text
EXISTING E5-B1-LS
AutoCAD SHX Text
NEW METERING PANEL
AutoCAD SHX Text REMOVE EXISTING LIGHTS IN ELECTRIC ROOMS. PROVIDE NEW LIGHTS IN EXISTING LOCATIONS OR AS INDICATED
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE: 1/8" = 1'-0"
AutoCAD SHX Text
%%U BASEMENT LEVEL ELECTRICAL PLAN
AutoCAD SHX Text
AutoCAD SHX Text 8'
AutoCAD SHX Text 16'
AutoCAD SHX Text 4'
VHANHMCarlaJ Polygon
VHANHMCarlaJ Polygon
VHANHMCarlaJ Text Box
This drawing shows the location of the existing panel room 027 in relation to the location of the new panel room 017.
DN
U P
D N
D N
UP
U P
Hatchway
014A
CRAWL SPACE
015 HALF DOOR
HALF DOOR CRAWL SPACE 016
ENG
ENG
HK
003 002
FC
EL
TR
5-017A
STORAGE
5-017B
05-EP101
BASEMENT NO. 05 BASEMENT
LEVEL ELECTRICAL PLAN 05
W.H.H. E.J.D.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
ISSUE FOR BIDOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
EHRM INFRASTRUCTURE UPGRADE
CENTRAL WESTERN MASSACHUSETTS
621-21-700
Project Director
06/06/ 2023Revisions: Date:
© Copyright 2022 DuBois & King Inc.
85 MAIN STREET
SPRINGFIELD, VT 05156
TEL: (802) 591-4326
FAX: (866) 783-7101
www.dubois-king.com
Edward P. VA Medical Center
I:\ 5\
A ce la
V A
EH
R
M In fra st ru ct ur e
IT
U pg ra de s\
D ra w in gs \E le ct ric al
\0 5-
EP
BA
SE
M
EN
T
N O
. 0
BA
SE
M
EN
T
LE
VE
L
EL
EC
TR
IC
AL
P
LA
N
.d w g
/2 /2
4:
:3
PM
AutoCAD SHX Text
EXISTING NORMAL POWER BREAKER
AutoCAD SHX Text
EXISTING EMERGENCY POWER BREAKER
AutoCAD SHX Text
EXISTING EEXISTING 5-MDP-2
AutoCAD SHX Text
EXISTING 5-MDP
AutoCAD SHX Text
EXISTING 5-EDP
AutoCAD SHX Text
EXISTING 5-MDP-3
AutoCAD SHX Text
EXISTING 5-B11
AutoCAD SHX Text
EXISTING 5-B2
AutoCAD SHX Text
EXISTING 5-B10
AutoCAD SHX Text
EXISTING E5-B2LS
AutoCAD SHX Text
EXISTING E5-LS
AutoCAD SHX Text
EXISTING E5-B1-LS
AutoCAD SHX Text
EXISTING METERING PANEL
AutoCAD SHX Text
EXISTING 5-B9
AutoCAD SHX Text
EXISTING 5-B8
AutoCAD SHX Text
EXISTING 5-B7
AutoCAD SHX Text
EXISTING 5-B6
AutoCAD SHX Text
EXISTING 5-B5
AutoCAD SHX Text
EXISTING 5-B4
AutoCAD SHX Text
EXISTING 5-B3
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE: 1/8" = 1'-0"
AutoCAD SHX Text
%%U BASEMENT LEVEL ELECTRICAL PLAN
AutoCAD SHX Text
AutoCAD SHX Text 8'
AutoCAD SHX Text 16'
AutoCAD SHX Text 4' malbitz Text Box 631-21-700
VHANHMCarlaJ Polygon
VHANHMCarlaJ Text Box
This drawing shows future work that will be completed in room 017 with a different contract.
ENG
TR
5-017A
STORAGE
5-017B
05-EP401
BUILDING NO. 05 ENLARGED TR
ROOM PLANS 05
W.H.H. E.J.D.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
ISSUE FOR BIDOffice of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
EHRM INFRASTRUCTURE UPGRADE
CENTRAL WESTERN MASSACHUSETTS
621-21-700
Project Director
06/06/ 2023Revisions: Date:
© Copyright 2022 DuBois & King Inc.
85 MAIN STREET
SPRINGFIELD, VT 05156
TEL: (802) 591-4326
FAX: (866) 783-7101
www.dubois-king.com
Edward P. VA Medical Center
I:\ 5\
A ce la
V A
EH
R
M In fra st ru ct ur e
IT
U pg ra de s\
D ra w in gs \E le ct ric al
\0 5-
EP
BU
IL
D
IN
G
N O
. 0
EN
LA
R G
ED
T
R R
O O
M P
LA
N
S.
dw g
1/ 2/
4:
:3
PM
AutoCAD SHX Text
GROUND BAR (SC-GND-1)
AutoCAD SHX Text
PANEL E5EB-B2
AutoCAD SHX Text
PANEL E5EB-B1
AutoCAD SHX Text
E5EB-B2-6
AutoCAD SHX Text
CU-5-1
AutoCAD SHX Text
E5EB-B1 -14,16
AutoCAD SHX Text
AC-5-1
AutoCAD SHX Text
E5EB-B2-2
AutoCAD SHX Text
ERV-5-1
AutoCAD SHX Text
E5EB-B2 -1,3,5
AutoCAD SHX Text
E5EB- B1-2
AutoCAD SHX Text
E5EB- B1-4
AutoCAD SHX Text
E5EB- B1-2
AutoCAD SHX Text
E5EB-B2-4
AutoCAD SHX Text
E5EB-B1 -1,3.5
AutoCAD SHX Text
EQUIPMENT LOCATED ON ROOF REFER TO MECHANICAL DRAWINGS FOR LOCATION
AutoCAD SHX Text
AC-5-2
AutoCAD SHX Text
CU-5-2
AutoCAD SHX Text
E5EB-B2 -14,16
AutoCAD SHX Text
E5EB- B1-12
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text BUILDING No. 5 - BASEMENT TR ROOM ELECTRICAL PLAN
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text 2'
AutoCAD SHX Text KEY NOTES: 2#12, 1#12G, 3/4"C TO 120VAC PANEL FEEDING EXISTING CIRCUITS IN THIS AREA PANEL. UTILIZE SPARE CIRCUIT BREAKER BREAKER FOR NEW EQUIPMENT. UPDATE PANEL SCHEDULE DIRECTORY WITH CHANGES.
malbitz Text Box 631-21-700
VHANHMCarlaJ Polygon
VHANHMCarlaJ Text Box
This drawing shows the locaiton of the new panel in relation to the future work.
| pictures #2 current conditions |
| Electrical Distribution System Upgrade Phase 2 7-26-23 |
| Sheets and Views |
| 05-EP101 BUILDING NO. 5 - BASEMENT LEVEL ELECTRICAL PLAN |
| Future Work |
| EHRM Project Electrical |
| 05-EP101 BASEMENT NO. 05 BASEMENT LEVEL ELECTRICAL PLAN |
| 05-EP401 BUILDING NO. 05 ENLARGED TR ROOM PLANS |
File details come from the government source that posted it. Updated .