This document is a solicitation for a new national cemetery development project in Cedar City, Utah. The Department of Veterans Affairs National Cemetery Administration is seeking bids for project number 942CM3001 to develop a new rural initiative cemetery. Services required include site preparation, construction of committal shelters, ornamental fencing, columbaria, memorial walls, and other cemetery infrastructure. The bid response due date is not specified. The awarded contractor will be responsible for completing all work in accordance with VA specifications and applicable codes.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
G
M
I N
H
M
I N
"F"
MIN. DIA.
"D"
"E"
"A" MIN. DIA.
"C"
"B"
NOTES:
THE UNDEREXPOSED SURFACE OF THE FLAGPOLE (BELOW GRADE)
SHALL RECEIVE A HEAVY COAT OF BLACK ASPHALTIC PAINT INSIDE
AND OUT BEFORE SHIPMENT
POLE MATERIAL:
FLAGPOLE SHALL BE MADE FROM 6063-T6 ALLOY SEAMLESS COLD
DRAWN EXTRUDED ALUMINUM TUBING
POLE FINISH: SEE SPEC 10 75 00
60' HT. POLE FLAG SIZE BASIS OF DESIGN 12'X18'. U.S. FLAG
GOVERNMENT PROVIDED.
E X
P O
S E
D
H
E I G
H T
GOLD ANODIZED ALUMINUM FINIAL BALL (SEE SPECS.)
CONE STYLE, REVOLVING, INTERNAL HALYARD TRUCK (SEE SPECS)
FLAG (N.I.C.) - PROVIDED BY OWNER, INSTALLED BY CONTRACTOR
COVERED COUNTERWEIGHT & NYLON BEADED RETAINER (SEE SPECS);
LOOP WITH NICKEL PLATED SNAP HOOKS
FIELD SPLICE: SEE SPECIFICATIONS FOR REQUIREMENTS IF APPLICABLE
(NOT ALLOWED FOR POLES LESS THAN OR EQUAL TO 35')
WINCH
ASSEMBLY
E.J.
FINISH
GRADE
FLAGPOLE (SEE SPEC 10 75 00)
SILICONE SEALANT AROUND
ALUMINUM FLASHING COLLAR
WATERPROOF CEMENT SEALANT 2" MIN. DEPTH
5" CONC. WALK PVMT.
4 HARDWOOD WEDGES (TEMP.)
PACKED DRY SAND
1/16" (16 GA.) GALV. CORRUG. STEEL SLEEVE EXTENDED UP
TO FINISH GRADE
4500 psi MIN. CONCRETE
4 STEEL WEDGES WELDED TO STEEL PLATE
WELDED STEEL BASE PLATE
6" SQUARE STEEL SUPPORT PLATE WELDED TO SPIKE
3/4" Ø x (MIN. 6" BELOW CONC.) ATTACH LIGHTENING KIT TO ROD
WELDED TO PLATES
LIGHTENING KIT COPPER WIRE (SEE SPEC 10 75 00)
EXISTING
SUBGRADE
1'-0"
MIN.,
TYP.
ENSURE POSITIVE DRAINAGE AWAY FROM BASE, TYP.
A-513
MISC SITE DETAILS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
N/A U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
18300 East 71st Ave., Denver, CO, 80249 504.684.4408; Sean Fitzpatrick
NATIONAL CEMETERY DEVELOPMENT
CEDAR CITY RURAL INITIATIVE
Cedar City, UT
942CM3001
N/A Project Director
5/22/2020Revisions: Date:
Steve Davis Department of Veterans Affairs, NCA
Phone: 202.632.4833 Email: steve.davis@va.gov Sheet of 54
Environment & Infrastructure Solutions, Inc.
BID DOCUMENTS
VCI Project Management Construction Management Engineering
National Cemetery Administration
Design and Construction
Service00404366
C O
L
O
R
A
D
O
L
I
C
E
N
S
E
D
A
R
C
H
I T
E
C
T
S E A
N
M
F
IT
Z
P
A
T
R
I C K
05/22/2020
E13/8" = 1'-0"
FLAG POLE DETAIL
F11" = 1'-0"
BENCH DETAIL
AutoCAD SHX Text 12'X18'
AutoCAD SHX Text
TOP
AutoCAD SHX Text
FOUNDATION
AutoCAD SHX Text
EXPOSED HT.
AutoCAD SHX Text 60.0'
AutoCAD SHX Text 3'-0"
AutoCAD SHX Text A
AutoCAD SHX Text
BOF
AutoCAD SHX Text E
AutoCAD SHX Text
BUTT
AutoCAD SHX Text
POLE
AutoCAD SHX Text
PLATE (SQ.)
AutoCAD SHX Text
SLEEVE
AutoCAD SHX Text
SLEEVE
AutoCAD SHX Text
SUPPORT
AutoCAD SHX Text
DIAMETER
AutoCAD SHX Text 15"
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text
FOUNDATION
AutoCAD SHX Text
DEPTH
AutoCAD SHX Text
SLEEVE
AutoCAD SHX Text
LENGTH
AutoCAD SHX Text
BASE
AutoCAD SHX Text
BASE PLATE
AutoCAD SHX Text
FOUNDATION
AutoCAD SHX Text F
AutoCAD SHX Text 6'-0"
AutoCAD SHX Text G
AutoCAD SHX Text H
AutoCAD SHX Text
TOF
AutoCAD SHX Text
MAX. FLAG SIZE
AutoCAD SHX Text 5'X8'
AutoCAD SHX Text 30.0'
AutoCAD SHX Text 16"
AutoCAD SHX Text 6"
AutoCAD SHX Text 10"
AutoCAD SHX Text 8"
AutoCAD SHX Text 3'-0"
AutoCAD SHX Text 12"
AutoCAD SHX Text 10"
AutoCAD SHX Text 20"
AutoCAD SHX Text 4'-0"
AutoCAD SHX Text 2'-0"
AutoCAD SHX Text 3'-0"
AutoCAD SHX Text 2'-0"
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
FLAG
AutoCAD SHX Text U.S.A.
AutoCAD SHX Text P.O.W.
AutoCAD SHX Text
1. BENCH, SEE SPEC SECTION 32 33 00 BENCH, SEE SPEC SECTION 32 33 00 2. (1) 5/8" I.D. STAINLESS STEEL ANCHOR BOLT W/ STAINLESS STEEL ACORN NUT (1) 5/8" I.D. STAINLESS STEEL ANCHOR BOLT W/ STAINLESS STEEL ACORN NUT (TYP. OF 4) INSTALLED AS PER MANUFACTURER'S INSTRUCTIONS. 3. COMMITTAL SHELTER SLAB, SEE DETAIL 1/S-501. COMMITTAL SHELTER SLAB, SEE DETAIL 1/S-501. 4. SUBGRADE, SEE DETAIL 1/S501.SUBGRADE, SEE DETAIL 1/S501.
AutoCAD SHX Text
KEYED NOTES
AutoCAD SHX Text
1075 BIG SHANTY ROAD, NW, SUITE 100 KENNESAW, GEORGIA 30144 (770) 421-3400
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
N/A U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
18300 East 71st Ave., Denver, CO, 80249 504.684.4408; Sean Fitzpatrick
Cedar City, UT
942CM3001
N/A Project Director
Revisions: Date:
Steve Davis Department of Veterans Affairs, NCA
Phone: 202.632.4833 Email: steve.davis@va.gov Sheet of
Environment & Infrastructure Solutions, Inc.
BID DOCUMENTS
VCI Project Management Construction Management Engineering
NATIONAL CEMETERY DEVELOPMENT
CEDAR CITY RURAL INITIATIVE
5/22/2020
National Cemetery Administration
Design and Construction
Service
18" AFF
18"AFF
48" AFF
18" AFF
48" AFF
1' ABOVE DOOR
7'-6" AFF (UNO)
MATCH EXISTING
48" AFF
MATCH EXISTINGFIRE ALARM PULL STATION
UNLESS NOTED OTHERWISE.
EXIT LIGHTS (WALL MTD.)
ANNUNCIATOR PANELS
FIRE ALARM AUDIO/VISUAL ALARM
EMERGENCY LIGHTS (WALL MTD.)
NOTE: DIMENSIONS ARE TO DEVICE CENTERLINE
LIGHT SWITCHES
RECEPTACLES
COMPUTER OUTLETS
TELEPHONE OUTLETS
TELEPHONE OUTLET (WALL MTD.)
GENERAL ELECTRICAL CONSTRUCTION NOTES
1. THE ELECTRICAL INSTALLATION SHALL CONFORM TO THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE, THE
AMERICANS WITH DISABILITIES ACT, AND OTHER APPLICABLE STATE AND LOCAL CODES.
2. THE ELECTRICAL CONTRACTOR SHALL COORDINATE THE WORK OF THEIR TRADE WITH THAT OF THE OTHER TRADES
INVOLVED IN THE PROJECT. CONFLICTS WITH OTHER TRADES SHALL BE BROUGHT TO THE ATTENTION OF THE PROJECT
SUPER INTENDENT PRIOR TO INSTALLATION. WORK SHOULD ALSO BE COORDINATED AROUND PORTABLE AND MOBILE
EQUIPMENT.
3. THE ELECTRICAL CONTRACTOR SHALL SCHEDULE THEIR WORK SO THAT THE CONSTRUCTION SCHEDULE IS MAINTAINED.
4. THE ELECTRICAL CONTRACTOR SHALL REQUEST A COMPLETE SET OF THE ARCHITECTURAL, STRUCTURAL, CIVIL, HVAC, PLUMBING, AND FIRE PROTECTION DRAWINGS TO VERIFY CONNECTIONS TO THE EQUIPMENT.
5. THE ELECTRICAL CONTRACTOR SHALL FURNISH MATERIALS AND LABOR FOR A COMPLETE ELECTRICAL INSTALLATION AS
INDICATED IN THESE DOCUMENTS. MATERIAL, APPARATUS, AND EQUIPMENT SHALL BE NEW AND SHALL BEAR THE
UNDERWRITERS LABORATORIES (UL) LABEL WHERE APPLICABLE.
6. THE ELECTRICAL CONTRACTOR SHALL PROVIDE TEMPORARY LIGHTING AND POWER SERVICE WHILE THE
BUILDING/RENOVATION AREA IS UNDER CONSTRUCTION ACCORDING TO CURRENT OSHA STANDARDS.
7. ALL CIRCUITS SHALL CONTAIN AN EQUIPMENT GROUNDING CONDUCTOR (GREEN COLORED INSULATION) ROUTED IN
CONDUIT AND SIZED PER NEC.
8. THE ELECTRICAL CONTRACTOR SHALL BE ALLOWED TO USE 3/4" MINIMUM ELECTRIC METALLIC TUBING (EMT) IN ALL AREAS
NOT EXPOSED TO PHYSICAL DAMAGE. COMPRESSION FITTINGS WITH INSULATED THROATS SHALL BE USED FOR EMT
CONDUITS 1-1/4" AND SMALLER. LARGER CONDUITS (1-1/2" AND GREATER) SHALL UTILIZE SET SCREW TYPE FITTINGS.
9. ALL CONDUIT 15'-0" AFF AND BELOW SHALL BE RIGID GALVANIZED STEEL (RGS) CONDUIT.
10. ALL CONDUITS BELOW GRADE SHALL BE PVC. ALL ELBOWS TURNING UP TOWARD ABOVE GRADE, AND ALL CONDUITS
EXPOSED ABOVE GRADE SHALL BE RGS.
11. FLEXIBLE (TYPE MC) CABLE SHALL BE ALLOWED FOR THE FLEXIBLE CONNECTIONS TO VIBRATING EQUIPMENT AND
RECESSED LIGHTING FIXTURES IN LAY-IN TYPE CEILINGS. A GROUNDING CONDUCTOR SHALL BE INCLUDED WITH THE POWER
CONDUCTORS INSIDE THE FLEXIBLE CONNECTION.
12. THE ELECTRICAL CONTRACTOR SHALL RUN LOW VOLTAGE (UNDER 100V) CONDUCTORS AND COMMUNICATIONS OR FIRE
ALARM CABLING IN CONDUIT. ALL DROPS TO DEVICES SHALL BE IN ACCORDANCE WITH NOTE 9 ABOVE.
13. THE ELECTRICAL CONTRACTOR SHALL UTILIZE TYPE THHN/THWN-2 CONDUCTORS IN ALL AREAS EXCEPT WHERE SERVICE
ENTRANCE CONDUCTORS ARE PROVIDED AS PART OF THE SCOPE OF WORK. WHERE SERVICE ENTRANCE CONDUCTORS
ARE PROVIDED AS PART OF THE SCOPE OF WORK THEY SHALL UTILIZE TYPE XHHW INSULATION. FOR ALL INSTANCES OF
MEDIUM VOLTAGE, PROVIDE CABLE SPECIFIED IN PROJECT SPECIFICATIONS.
14. THE ELECTRICAL CONTRACTOR SHALL PROVIDE COPPER CONDUCTORS. CONDUCTORS SHALL BE SOLID FOR SIZES #10 AWG
AND SMALLER. CONDUCTORS #8 AWG AND LARGER SHALL BE STRANDED.
15. THE ELECTRICAL CONTRACTOR SHALL LIMIT LIGHTING AND RECEPTACLE BRANCH CIRCUIT HOMERUNS TO 5 CONDUCTORS: 3
PHASE CONDUCTORS, 1 NEUTRAL CONDUCTOR, AND 1 EQUIPMENT GROUNDING CONDUCTOR.
16. THE ELECTRICAL CONTRACTOR SHALL PROVIDE THE FOLLOWING COLOR CODING OF CIRCUITS/FEEDERS.
CIRCUITS/FEEDERS RATED 13.8KV /2400V/ 480Y/277V:
PHASE "A" = BROWN
PHASE "B" = ORANGE
PHASE "C" = YELLOW
NEUTRAL = GRAY
GROUNDING = GREEN
ISOLATED G = GREEN/YELLOW STRIPE
CIRCUITS/FEEDERS RATED 240/120V or 208Y/120V:
PHASE "A" = BLACK
PHASE "B" = RED
PHASE "C" = BLUE
NEUTRAL = WHITE
GROUNDING = GREEN
ISOLATED G = GREEN/YELLOW STRIPE
17. ALL DISCONNECT SWITCHES SHALL BE HEAVY DUTY TYPE, AND FUSIBLE WHERE INDICATED.
18. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL NECESSARY ADDITIONAL SUPPORT FOR ALL ELECTRICAL EQUIPMENT
WHERE THE BUILDING STRUCTURE IS NOT SUITABLE FOR A PROPERLY SUPPORTED INSTALLATION.
19. THE ELECTRICAL CONTRACTOR SHALL PROVIDE AN OUTLET BOX FOR EACH LIGHTING FIXTURE, WIRING DEVICE, OR
JUNCTION POINT. ELECTRICAL BOXES SHALL BE OF SUFFICIENT CAPACITY FOR THE NUMBER OF CONDUCTORS AND SPLICES
WITHIN THE BOX; IN ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE.
20. DEVICE PLATES SHALL BE INSTALLED ON OUTLETS FOR ALL SWITCHES, RECEPTACLES, ETC. AND COLOR SHALL BE AS
SELECTED BY ARCHITECT. WHERE MORE THAN ONE SWITCH IS INDICATED IN THE SAME LOCATION, SWITCHES SHALL BE
GANGED UNDER A COMMON ONE-PIECE PLATE. MULTIPIECE COVER PLATES ARE NOT ACCEPTABLE.
21. THE ELECTRICAL CONTRACTOR SHALL FIRESTOP, DRAFT STOP, AND/OR PROTECT THE ANNULAR SPACE AROUND ALL
RACEWAY, CONDUIT, WIRE, AND CABLE PENETRATIONS THROUGH WALLS, PARTITIONS, FLOORS, CEILINGS AND ROOFS IN
ACCORDANCE WITH THE REQUIREMENTS OF THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE AND UL LISTING
REQUIREMENTS.
22. ALL INTERIOR BRANCH CIRCUITS SHALL BE INSTALLED OVERHEAD INSIDE BUILDINGS.
23. UNDERGROUND EXTERIOR BRANCH CIRCUITS SHALL BE RAN OVERHEAD INSIDE BUILDINGS TO AN EXTERIOR WALL, THEN
DOWN BEFORE PENETRATING THE EXTERIOR WALL AND LEAVING THE BUILDING UNDERGROUND.
24. ALL EXTERIOR UNDERGROUND BRANCH CIRCUITS SHALL BE INSTALLED LAST AFTER ALL OTHER UNDERGROUND UTILITY
WORK ASSOCIATED WITH THIS PROJECT IS COMPLETE.
25. THE ELECTRICAL CONTRACTOR SHALL LABEL EACH RECEPTACLE, DISCONNECT, AND MISCELLANEOUS EQUIPMENT WITH
BOTH THE PANELBOARD AND CIRCUIT NUMBER. PROVIDE SELF ADHESIVE LABEL TO DEVICE COVERPLATE.
(GENERAL NOTES APPLY TO ALL DRAWINGS)
DOUBLE TWIN TUBE
ELECTRICAL METALLIC TUBING
EXHAUST FAN
EMERGENCY
EQUIPMENT
EMPTY CONDUIT
DRAWING(S)
EXISTING
ELECTRIC WATER COOLER
ELECTRIC WATER HEATER
FIRE ALARM CONTROL PANEL
FURNISHED BY OTHERS
GROUND
HORSEPOWER
ELECTRONIC BALLAST
FURNISHED WITH EQUIPMENT
GROUND FAULT INTERRUPTERGFI
HP
GND
EXIST
FBO
FACP
FWE
EF
EMT
EQUIP
EWH
EWC
EM
DTT
DWG
EC
EB
ASYMMETRICAL INTERRUPTING
AMPERES
CONDUIT
CATALOG
ABOVE FINISHED FLOOR
AIR HANDLING UNIT
C
CAT
AIC
AFF
AHU
A
CURRENT
ABBREVIATIONS
HID HIGH INTENSITY DISCHARGE
EACHEA
ENCLOSED CIRCUIT BREAKERECB
BELOW FINISHED GRADEBFG
IMC INTERMEDIATE METAL CONDUIT
JB JUNCTION BOX
XFMR
WP
VA
V
UH
UNO
TYP
REQD
RTU
RGS
RM
RECEPT
PNL
PB
NEC
NTS
OFCI
NF
MTG
N
MLO
MT
MTD
MCB
MCCB
LTG
UNLESS NOTED OTHERWISE
VOLT-AMPERE(S)
WEATHERPROOF
TRANSFORMER
VOLT(S)
UNIT HEATER
TYPICAL
RIGID GALVANIZED STEEL CONDUIT
REQUIRED
ROOF TOP UNIT
ROOM
PUSH BUTTON
INSTALLED
RECEPTACLE
PANEL(S)
OWNER FURNISHED, CONTRACTOR
NATIONAL ELECTRICAL CODE
NON FUSED
NOT TO SCALE
MOUNTING
MAIN LUGS ONLY
NEUTRAL
MOUNT
MOUNTED
MOLDED CASE CIRCUIT BREAKER
MAIN CIRCUIT BREAKER
LIGHTING
TYPICAL DEVICE MOUNTING HEIGHT
AUTOMATIC TRANSFER SWITCHATS
NIC NOT IN CONTRACT
SURFACE MOUNTED PANELBOARD.
MOTOR, HORSEPOWER AS INDICATED.
FLUSH MOUNTED DUPLEX CONVENIENCE OUTLET NEMA 5-20R, 120V, 20 AMP,
3 WIRE, MOUNTED 18" AFF, "*" IF SUBSCRIPT APPLIES, SEE BELOW:
- INDICATES GROUND FAULT INTERRUPTING TYPE.
- INDICATES COUNTER TOP RECEPTACLE MOUNTED 6" ABOVE
"GFI"
"WP"
"C"
- INDICATES WEATHERPROOF COVER.
COUNTER TOP.
JUNCTION BOX, CEILING MOUNTED
5 HP
HEAVY DUTY DISCONNECT SWITCH, RATINGS AS INDICATED (AMPS/POLES/
DRY TYPE TRANSFORMER WITH VOLTAGES, KVA, AND PHASES AS
NAMEPLATE DATA. "*" SUBSCRIPT INDICATES STARTER SIZE.
"HOA" - INDICATES "HAND-OFF-AUTO" SELECTOR SWITCH MOUNTED ON DOOR.
/ENCLOSURE). NON-FUSED SWITCH TYPE. OVERLOADS SIZED PER MOTOR
"00" - INDICATES "ON-OFF" SELECTOR SWITCH MOUNTED ON DOOR.
ELECTRICAL SYMBOL LEGEND
CONDUIT TURNING UP
CONDUIT ROUTED EXPOSED
CONDUIT TURNING DOWN
EQUIPMENT AS NOTED.
/ENCLOSURE) FUSED IF INDICATED.
EXAMPLE OF WIRING AND CONDUIT NOTATION.
3#10, #10G, 1"C
30/3/3R
HOA
SHOWN ON DRAWINGS.
SYMBOL
T
DESCRIPTION
CONDUIT ROUTED CONCEALED ABOVE DROPPED CEILING AND/OR WALLS.
30/3/1
OR
RECESSED MOUNTED PANELBOARD.
CONDUIT WITH THREE CONDUCTORS, ONE NEUTRAL AND ONE GROUND
JUNCTION BOX, WALL MOUNTED
J
J
THERMOSTAT BY OTHERST
* IF SUBSCRIPT APPLIES, SEE BELOW:
SINGLE POLE LIGHT SWITCH, FLUSH MOUNTED 48" AFF, 120/277V, 20AMP.
ON STRIKE SIDE OF DOOR OR WHERE OTHERWISE INDICATED ON PLANS.
"K" - KEY OPERATED SINGLE POLE SWITCH. SWITCH SHALL INTERRUPT
UNSWITCHED PHASE CONDUCTOR SERVING EMERGENCY LIGHTING
UNITS FOR TESTING PURPOSES.
"OC"- DUAL TECHNOLOGY WALL OCCUPANCY SENSOR, WATTSTOPPER #DW-100-W
OS
WALL MOUNTED OCCUPANCY SENSOR WITH PROGRAMMABLE TIME-DELAY, SET AT 30 MIN.
LIGHTING FIXTURE SCHEDULE
SYMBOL TYPE DESCRIPTION MANUFACTURER MODEL VOLTAGE WATTS MOUNTING
B IN GROUND MOUNTED FLOOD-LIGHT WITH AIMABLE LAMP
AND FLOOD GUARD.
KIM LIGHTING LTV81FF-SS-SP-24L-RGBW-UV
OR APPROVED EQUAL
120 V 30W MOUNTED IN GROUND SEE DETAIL ON THIS SHEET
SPEAKER
FLAG POLE FIXTURE MOUNTING DETAIL
HANDHOLE DETAIL
HANDHOLE SCHEDULE
SYMBOL TYPE DESCRIPTION
L LARGE HANDHOLE (W:28"x L:28" x H:24")
S SMALL HANDHOLE (W:12" x L:12" x H:12") L s
UNDERGROUND CONDUIT DETAIL
SPD SURGE PROTECTION DEVICE
GATE CONTROL RISER
B
E-001
MG JSC
ELECTRICAL NOTES & LEGENDS
E
T T
Y S
B U
R G
P L
A Q
U E
G
R
A
V
E
S
IT
E
L
O
C
A
T
O
R
K
IO
S
K
B
IV
O
U
A
C
O
F
T
H
E
D
E
A
D
P
L
A
Q
U
E
PATR
IO
TIC
SLOGAN
EH-1
S
S
E H
-1
S
S
S
E
C
T
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
N/A U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
18300 East 71st Ave., Denver, CO, 80249 504.684.4408; Sean Fitzpatrick
Cedar City, UT
942CM3001
N/A Project Director
Revisions: Date:
Steve Davis Department of Veterans Affairs, NCA
Phone: 202.632.4833 Email: steve.davis@va.gov Sheet of
Environment & Infrastructure Solutions, Inc.
BID DOCUMENTS
VCI Project Management Construction Management Engineering
NATIONAL CEMETERY DEVELOPMENT
CEDAR CITY RURAL INITIATIVE
5/22/2020
National Cemetery Administration
Design and Construction
Service
NEW WORK KEY NOTES:
ELECTRICAL SITE - PLAN
ELECTRICAL - PUMP HOUSE
ELECTRICAL - COMMITTAL SHELTER
LB1, CKT- 2, 4
LB1, CKT- 1
LC1, CKT- 1
LC1, CKT- 2, 4
B
B
GATE #2
GATE #1
ELECTRICAL - GATE #1
ELECTRICAL - GATE #2
LD1, CKT- 2
LB1, CKT- 3
LC1, CKT- 3
LA1, CKT- 2, 4
B
LB1, CKT- 5
LD1, CKT- 1
LB1, CKT- 6
LC1, CKT- 6
L
BOOSTER PUMPS AND
VFD/CONTROLLERS
GENERAL NOTES:
J
J
ELECTRICAL SITE - PLAN
TYP. (3)
3" CONDUIT TO EXISTING
PAD MOUNTED SWITCH
E-101
MG JSC
ELECTRICAL SITE PLAN
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
N/A U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
18300 East 71st Ave., Denver, CO, 80249 504.684.4408; Sean Fitzpatrick
Cedar City, UT
942CM3001
N/A Project Director
Revisions: Date:
Steve Davis Department of Veterans Affairs, NCA
Phone: 202.632.4833 Email: steve.davis@va.gov Sheet of
Environment & Infrastructure Solutions, Inc.
BID DOCUMENTS
VCI Project Management Construction Management Engineering
NATIONAL CEMETERY DEVELOPMENT
CEDAR CITY RURAL INITIATIVE
5/22/2020
National Cemetery Administration
Design and Construction
Service ɸ ɸ ɸ
IRRIGATION PANEL LA1 - NEW
GATE PANEL LC1 - NEW
PARTIAL ONE-LINE DIAGRAM
ɸ
GATE PANEL LB1 - NEW
ɸ
SHELTER PANEL LD1 - NEW
SPEAKER WIRING DIAGRAM
SPEAKER ROUTING DIAGRAM
E-601
MG JSC
ELECTRICAL SCHEDULES
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
N/A U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
18300 East 71st Ave., Denver, CO, 80249 504.684.4408; Sean Fitzpatrick
Cedar City, UT
942CM3001
N/A Project Director
Revisions: Date:
Steve Davis Department of Veterans Affairs, NCA
Phone: 202.632.4833 Email: steve.davis@va.gov Sheet of
Environment & Infrastructure Solutions, Inc.
BID DOCUMENTS
VCI Project Management Construction Management Engineering
NATIONAL CEMETERY DEVELOPMENT
CEDAR CITY RURAL INITIATIVE
5/22/2020
National Cemetery Administration
Design and Construction
Service
A.DESIGN CRITERIA
1. 2018 INTERNATIONAL BUILDING CODE
2. ASCE 7-16 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES.
3. ACI 301-10 SPECIFICATIONS FOR STRUCTURAL CONCRETE.
4. ACI 318-14 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AND COMMENTARY.
5. ACI 530-13 BUILDING CODE REQUIREMENTS AND SPECIFICATIONS FOR MASONRY STRUCTURES.
6. AISC 360-16 SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS.
7. DESIGN DEAD LOADS:
CONCRETE 150 PCF
MASONRY 135 PCF
SHELTER (SELF WEIGHT) (ACTUAL)
COLLATERAL DL 3 PSF
8. DESIGN LIVE LOADS:
ROOF (NON REDUCIBLE) 20 PSF
SLAB ON GRADE 150 PSF
9. WIND DESIGN DATA:
ULTIMATE DESIGN WIND SPEED (3 SECOND GUST) ASCE 7-16 (MWFRS) Vult = 101 MPH
RISK CATEGORY II
EXPOSURE CATEGORY C
TOPOGRAPHIC FACTOR Kzt = 1.0
GUST-EFFECT FACTOR G = 0.85
ENCLOSURE CLASSIFICATION OPEN
INTERNAL PRESSURE COEFFICIENT GCpi = +/- 0.00
10. EARTHQUAKE DESIGN DATA:
RISK CATEGORY II
SEISMIC IMPORTANCE FACTOR Ie = 1.00 MAPPED SPECTRAL RESPONSE ACCELERATION PARAMETER AT SHORT PERIODS SS = 0.79g MAPPED SPECTRAL RESPONSE ACCELERATION PARAMETER AT A PERIOD OF 1 SEC S1 = 0.255g
SITE CLASS D
DESIGN SPECTRAL RESPONSE ACCELERATION PARAMETER AT SHORT PERIODS SDS = 0.631g DESIGN SPECTRAL RESPONSE ACCELERATION PARAMETER AT A PERIOD OF 1 SEC SD1 = 0.254g
SEISMIC DESIGN CATEGORY D
ANALYSIS PROCEDURE USED: (DETERMINED BY SHELTER VENDOR)
BASIC SEISMIC FORCE-RESISTING SYSTEM: (DETERMINED BY SHELTER VENDOR)
RESPONSE MODIFICATION FACTOR (DETERMINED BY SHELTER VENDOR)
SEISMIC RESPONSE COEFFICIENT (DETERMINED BY SHELTER VENDOR)
SEISMIC BASE SHEAR (DETERMINED BY SHELTER VENDOR)
B.GENERAL
1. VERIFY ALL EXISTING CONDITIONS, DIMENSIONS AND ELEVATIONS BEFORE STARTING WORK. NOTIFY THE NCA COR/PM IN WRITING OF CONDITIONS
ENCOUNTERED IN THE FIELD CONTRADICTORY TO THOSE SHOWN ON THE STRUCTURAL CONTRACT DOCUMENTS.
2. PROVIDE ADEQUATE BRACING FOR STRUCTURES SO THAT THEY WILL BE STABLE DURING ALL STAGES OF CONSTRUCTION. THE STRUCTURES AND
FOUNDATIONS ARE DESIGNED FOR A COMPLETED CONDITION ONLY AND THEREFORE REQUIRE ADDITIONAL SUPPORT TO MAINTAIN STABILITY BEFORE COMPLETION. STRUCTURES SHALL BE CONSIDERED COMPLETE WHEN ALL STRUCTURAL MEMBERS ARE COMPLETED AND HAVE ATTAINED THEIR
SPECIFIED DESIGN STRENGTH AS SHOWN ON THE DRAWINGS.
3. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE DESIGN, ADEQUACY AND SAFETY OF ERECTION BRACING SHORING, TEMPORARY SUPPORTS, ETC.
4. COORDINATE NCA COR/PM CONTRACT DOCUMENTS WITH CIVIL AND ARCHITECTURAL. NOTIFY STRUCTURAL ENGINEER OF ANY CONFLICT AND/OR
OMISSION.
5. REVIEW OF SUBMITTALS AND/OR SHOP DRAWINGS BY THE NCA COR/PM DOES NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY TO REVIEW
AND CHECK SHOP DRAWINGS BEFORE SUBMITTAL TO THE NCA COR/PM. THE CONTRACTOR REMAINS SOLELY RESPONSIBLE FOR ERRORS AND OMISSIONS ASSOCIATED WITH THE PREPARATION OF SHOP DRAWINGS AS THEY PERTAIN TO MEMBER SIZES, DETAILS AND DIMENSIONS SPECIFIED IN THE CONTRACT DOCUMENTS. THE CONTRACTOR IS ALSO RESPONSIBLE FOR MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES OF
CONSTRUCTION.
C.FOUNDATIONS
1. THE DESIGN OF THE FOUNDATIONS AND SLAB IS BASED ON CRITERIA ESTABLISHED IN THE REPORT OF GEOTECHNICAL EXPLORATION PREPARED BY
GEM ENGINEERING, INC DATED MARCH, 16 2020. FOUNDATIONS AND THICKENED SLABS ARE DESIGNED FOR AN ALLOWABLE NET SOIL BEARING
CAPACITY OF 2500PSF.
2. A GEOTECHNICAL ENGINEER REGISTERED IN THE STATE OF UTAH SHALL INSPECT THE CONDITION AND ASSURE THE ADEQUACY OF ALL SUB GRADES, FILLS AND BACK FILLS BEFORE PLACEMENT OF FOUNDATIONS, FOOTINGS, SLABS AND WALLS .CONTRACTOR SHALL SUBMIT REPORTS TO THE NCA PM/ COR DESCRIBING HIS FINDINGS, INCLUDING ANY NON-CONFORMING WORK. SUBMIT A COMPLETED FINAL REPORT OF SPECIAL INSPECTIONS AT THE
COMPLETION OF SPECIAL INSPECTION ACTIVITIES.
3. GROUND WATER SHALL BE KEPT AT LEAST 3 FEET BELOW THE DEEPEST FOUNDATION BEARING ELEVATION DURING CONSTRUCTION.
4. FOOTINGS MAY BE CAST INTO AN EARTH FORMED TRENCH IF SOIL CONDITIONS PERMIT.
5. EXCAVATION FOR FOOTING SHALL BE CUT TO ACCURATE SIZE AND DIMENSIONS AS SHOWN ON PLANS. ALL SOIL BELOW SLAB AND FOOTINGS SHALL BE
PROPERLY COMPACTED AND SUB-GRADE BROUGHT TO A REASONABLE TRUE AND LEVEL PLANE BEFORE PLACING CONCRETE.
6. FOOTING CONCRETE SHALL BE CAST ON THE SAME DAY THE EXCAVATION IS APPROVED. IF THE BEARING SURFACE IS ALLOWED TO BECOME
DISTURBED IN ANY WAY, IT SHALL BE REWORKED TO THE SATISFACTION OF THE GEOTECHNICAL ENGINEER PRIOR TO CASTING OF THE CONCRETE.
7. NO EXCAVATION SHALL BE CLOSER THAN A SLOPE OF 3:1 (3 HORIZONTAL TO 1 VERTICAL) TO A FOOTING. PROVIDE SHORING AND PROTECTION FOR
EXCAVATION BANKS AS NECESSARY TO PRESERVE SAFETY AND PREVENT CAVING.
8. ALL BEARING STRATA SHALL BE ADEQUATELY DRAINED BEFORE FOUNDATION CONCRETE IS PLACED.
9. THERE SHALL BE NO HORIZONTAL OR VERTICAL CONSTRUCTION JOINTS IN ANY FOUNDATION WITHOUT PRIOR WRITTEN APPROVAL FROM THE NCA
COR/PM, EXCEPT WHERE INDICATED ON THE DRAWINGS.
10. CONCRETE CAST ON SLOPING SURFACES SHALL BEGIN AT THE LOWEST ELEVATION AND CONTINUE MONOLITHICALLY TOWARD THE HIGHER ELEVATION
UNTIL THE INTENDED POUR IS COMPLETED.
11. FROST DEPTH IS 30 INCHES BELOW GRADE. FOUNDATIONS TO BEAR BELOW FROST DEPTH OR ON NON-FROST SUSCEPTIBLE MATERAL WHICH EXTENDS
BELOW THE FROST DEPTH WHERE NOTED ON THE DRAWINGS. NON-FROST SUSCEPTIBLE MATERIAL IS DEFINED AS GRANULAR FILL CLASSIFIED GW OR GP PER UNIFIED SOIL CLASSIFICATION WITH 3 TO 5% FINER THAN 0.02mm BY WEIGHT, AND ACCEPTABLE TO THE TESTING AGENCY.
D.CONCRETE
1. ALL CONCRETE WORK SHALL CONFORM TO ACI 301-10 SPECIFICATIONS FOR STRUCTURAL CONCRETE. DESIGN IS BASED ON ACI 318-14 BUILDING CODE
REQUIREMENTS FOR STRUCTURAL CONCRETE AND COMMENTARY.
2. PORTLAND CEMENT SHALL CONFORM TO ASTM C150 TYPE V.
3. PROVIDE MAXIMUM WATER - CEMENTITIOUS MATERIAL RATIO OF 0.45
4. AIR CONTENT EXPOSED TO FREEZE THAW
34 AGGREGATE: 6 ±1.5
112 AGGREGATE: 5.5 ±1.5
5. CONCRETE SHALL HAVE A 28 DAY COMPRESSIVE STRENGTH IN ACCORDANCE WITH THE FOLLOWING:
LOCATION STRENGTH
FOUNDATIONS 4500 PSI
SLAB ON GRADE 4500 PSI
ALL OTHER CONCRETE 4500 PSI
6. THE PROPOSED MATERIALS AND MIX DESIGN SHALL BE FULLY DOCUMENTED AND REVIEWED BY AN INDEPENDENT TESTING LABORATORY AND SUBMITTED TO THE NCA PM/COR FOR REVIEW A MINIMUM OF 15 DAYS PRIOR TO USE. RESPONSIBILITY FOR OBTAINING THE REQUIRED DESIGN
STRENGTH IS THE CONTRACTOR'S.
7. ALL MIXING, TRANSPORTING, PLACING AND CURING OF CONCRETE SHALL BE DONE IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE AMERICAN
CONCRETE INSTITUTE.
8. USE OF CALCIUM CHLORIDE, CHLORIDE IONS OR OTHER SALTS IN CONCRETE IS NOT PERMITTED.
9. REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60 UNLESS NOTED OTHERWISE.
10. WELDED WIRE REINFORCEMENT (W.W.R.) SHALL CONFORM TO ASTM A185 AND SHALL BE PROVIDED IN FLAT SHEETS (ROLLS NOT PERMITTED). LAP TWO
SQUARES AT SPLICES.
11. UNLESS NOTED OTHERWISE, SAMPLES FOR STRENGTH TESTS OF EACH CLASS OF CONCRETE PLACED EACH DAY SHALL BE TAKEN BY THE TESTING
AGENCY NOT LESS THAN ONCE A DAY, NOR LESS THAN ONCE FOR EACH 100 CUBIC YARDS OF CONCRETE, NOR LESS THAN ONCE FOR EACH 5000 SQUARE FEET OF SURFACE AREA FOR SLABS AND WALLS. IF THE ABOVE FREQUENCY WOULD RESULT IN LESS THAN 5 STRENGTH TESTS FOR A GIVEN CLASS OF CONCRETE, TEST 5 RANDOMLY SELECTED BATCHES OR EACH BATCH IF FEWER THAN 5 BATCHES ARE USED. SAMPLE CONCRETE IN ACCORDANCE WITH ASTM C172. PERFORM THE FOLLOWING TESTS IN ACCORDANCE WITH THE INDICATED STANDARD:
· SLUMP: ASTM C143
· AIR CONTENT: ASTM C231 OR C173
· COMPRESSIVE STRENGTH: ASTM C39, WITH ONE CYLINDER AT 7 DAYS, 2 CYLINDERS AT 28 DAYS, AND ONE SPECIMEN HELD IN RESERVE.
12. HORIZONTAL CONSTRUCTION JOINTS ARE PERMITTED ONLY WHERE INDICATED. THE LOCATION OF VERTICAL CONSTRUCTION JOINTS SHALL BE APPROVED BY THE STRUCTURAL ENGINEER. CONSTRUCTION JOINTS SHALL BE THOROUGHLY ROUGHENED BY MECHANICAL MEANS AND CLEANED.
13. PROVIDE CONTINUOUS REINFORCEMENT WHEREVER POSSIBLE; SPLICE ONLY AS SHOWN OR APPROVED; STAGGER SPLICES WHERE POSSIBLE; USE CLASS "B" TENSION SPLICE UNLESS NOTED OTHERWISE. DOWELS SHALL MATCH THE SIZE AND SPACING OF THE SPECIFIED REINFORCEMENT AND SHALL BE LAPPED WITH CLASS "B" TENSION SPLICES. UNLESS NOTED OTHERWISE LAP LENGTHS EXPRESSED IN NUMBER OF BAR DIAMETERS SHALL BE AS FOLLOWS. APPROVED MECHANICAL COUPLERS MAY BE USED IN LIEU OF PHYSICAL SPLICING:
NOTE:
TOP BARS ARE HORIZONTAL BARS WHERE THE DEPTH OF CONCRETE CAST IN ONE LIFT BENEATH THE BAR EXCEEDS 12". PROVIDE TOP BAR LAP
SPLICE LENGTH FOR ALL CONCRETE WALL HORIZONTAL BARS.
14. MINIMUM CONCRETE COVER (UNLESS NOTED OTHERWISE) SHALL BE:
15. SCHEDULED OR DETAILED REINFORCING STEEL SHALL NOT BE TACK WELDED FOR ANY REASON. WELDED REINFORCING STEEL SPLICES ARE NOT PERMITTED WITHOUT ENGINEER APPROVAL. WHERE WELDING IS APPROVED IT SHALL CONFORM TO AWS D1.4 STRUCTURAL WELDING CODE -
REINFORCING STEEL.
16. SAWN CONTROL JOINTS SHALL BE PLACED AS SOON AS CONCRETE IS ABLE TO BE SAWN WITHOUT PULLING AGGREGATE FROM FLOOR USING A DRY-CUT EARLY ENTRY SAW. SLABS SHALL NOT BE LEFT OVERNIGHT, OR ANY REASONABLE AMOUNT OF TIME, WITHOUT SAWING JOINTS. WEATHER IS CRITICAL TO SCHEDULE SAWING OF JOINTS. IF LARGE AREAS OF SLAB ARE POURED AT ONE TIME, SEVERAL SAWS MAY BE REQUIRED TO PROVIDE JOINTS IN TIME TO PREVENT SHRINKAGE CRACKING. PROPER JOINTING OF SLAB IS CRITICAL. REFER TO ACI MANUAL OF CONCRETE PRACTICE FOR
PROPER JOINTING TECHNIQUES.
17. PROVIDE A MINIMUM OF 5 BOLT DIAMETERS COVER FOR ANCHOR BOLTS AND LOCATE HORIZONTAL REINFORCEMENT TO THE OUTSIDE FOR ANCHOR
BOLT CONTAINMENT, U.N.O.
18. PROVIDE TEMPORARY SHORING AND BRACING OF ALL STRUCTURAL AND MISCELLANEOUS ELEMENTS UNTIL CONCRETE HAS OBTAINED DESIGN
STRENGTH AND ALL PERMANENT BRACING ELEMENTS ARE INSTALLED.
19. WHEN PLACING CONCRETE UNDER HOT OR COLD WEATHER CONDITIONS COMPLY WITH THE LATEST EDITIONS OF ACI305R: "HOT WEATHER
CONCRETING" OR ACI306R: "COLD WEATHER CONCRETING".
20. TIE ALL REINFORCING STEEL AND EMBEDMENTS SECURELY IN PLACE PRIOR TO PLACING CONCRETE. PROVIDE SUFFICIENT SUPPORTS TO MAINTAIN THE POSITION OF REINFORCEMENT AND EMBEDMENTS WITHIN SPECIFIED TOLERANCES DURING ALL CONSTRUCTION ACTIVITIES. "STICKING" DOWELS
INTO WET CONCRETE IS NOT PERMITTED.
21. ELASTOMERIC JOINT SEALANT: DOW CORNING 888 NON-SAG SILICONE JOINT SEALANT FOR PORTLAND CEMENT CONCRETE PAVEMENT JOINTS.
22. JOINT BACK-UP MATERIAL: POLYETHYLENE FOAM, CLOSED CELL. USE WITH ELASTOMERIC JOINT SEALANT ONLY.
23. SUBMIT REINFORCING BAR SHOP DRAWINGS INCLUDING PLACEMENT PLANS, BAR BENDING DIAGRAMS SPLICE LENGTHS AND LOCATIONS, BAR SPACING, CONCRETE COVER, SUPPORT DEVICES AND ACCESSORIES CONFORM TO ACI 318 AND ACI SP-66.
24. SUBMIT PROPOSED CURING METHODS AND MATERIALS A MINIMUM OF 15 DAYS PRIOR TO USE.
25. TOLERANCES SHALL CONFORM TO ACI 117 AND ACI 347.
26. LIQUID CURING AND SEALING COMPOUND: ASTM C1315, TYPE 1 (VOC COMPLIANT, 350 g/L) STYRENE ACRYLATE OR METHACRYLATE TYPE 25% MINIMUM
SOLIDS CONTENT, CLEAR, NON-YELLOWING. STYRENE BUTADIENE NOT ALLOWED AS PART OF THE BLEND. PRIOR TO TURNOVER OF PROJECT TO
OWNER, CLEAN THE SLAB-ON-GRADE
27. THE FOLLOWING SHALL CONFORM TO THE FOLLOWING GRADES:
ANCHOR BOLTS ASTM F1554, GRADE 36, U.N.O.
EXPANSIVE JOINT FILLER ASTM D1752, WITH COMPRESSION OF 10PSI TO 25PSI
NON-EXTRUDING 1/4" THICK U.N.O., FULL DEPTH OF CONCRETE. BLOCK OUT FILLER AT TOP TO
ALLOW FOR SEALANT AND BACKER ROD. ACCEPTABLE PRODUCTS: SONNEBORN "EXPANSION
JOINT FILLER" AND W.R. MEADOWS 'CERAMAR".
E.MASONRY GENERAL NOTES:
1. CONCRETE MASONRY DESIGN AND CONSTRUCTION SHALL CONFORM TO: ACI 530-13/ASCE 5-13, BUILDING CODE REQUIREMENTS FOR
MASONRY STRUCTURES. ACI 530.1-13/ASCE 6-13, SPECIFICATIONS FOR MASONRY STRUCTURES.
2. PROVIDE NORMAL WEIGHT, HOLLOW, LOAD-BEARING CONCRETE MASONRY UNITS (CMU) CONFORMING TO ASTM C90.
3. PROVIDE CONCRETE MASONRY WITH MINIMUM AVERAGE COMPRESSIVE STRENGTH,
f'm = 2,000 PSI.
4. PROVIDE TYPE "S" MORTAR IN ACCORDANCE WITH ASTM C270, U.N.O. MORTAR BED JOINTS SHALL NOT EXCEED 3/8" THICKNESS.
5. PROVIDE GROUT FOR REINFORCED MASONRY IN ACCORDANCE WITH ASTM C476 WITH MINIMUM COMPRESSIVE STRENGTH OF 2,500 PSI
UNLESS NOTED OTHERWISE.
6. PROVIDE HORIZONTAL JOINT REINFORCEMENT LADDER TYPE COMPLYING WITH ASTM A82, NO. 9 GAUGE OR HEAVIER, ZINC COATED, PLACED 16 INCHES ON CENTER UNLESS NOTED OTHERWISE.
7. PROVIDE MINIMUM 2#5 VERTICAL IN TWO ADJACENT CELLS GROUTED FULL HEIGHT, AT EACH SIDE OF OPENINGS AND WALL ENDS, AND EACH
SIDE OF MASONRY CONTROL JOINTS.
8. LAY MASONRY UNITS IN RUNNING BOND UNLESS NOTED OTHERWISE.
9. SIDES AND TOPS OF MASONRY WALL PANELS SHALL BE ANCHORED TO STRUCTURE AND AT 16"O.C. TO STRUCTURE BY DOVETAIL ANCHORS, METAL STRAPS, OR EQUIVALENT UNLESS NOTED OTHERWISE.
10. FOR OPENINGS IN MASONRY WALLS GREATER THAN 2'-0", PROVIDE STRUCTURAL LINTEL ABOVE OPENINGS. USE REINFORCED STRUCTURAL
LINTEL GROUTED SOLID.
11. MASONRY TO BE INSPECTED PER INTERNATIONAL BUILDING CODE SECTION 1705.4, REQUIRED VERIFICATION AND INSPECTION OF MASONRY
CONSTRUCTION.
12. ALL CONCRETE MASONRY UNITS REINFORCING (VERT. & HORIZ.) SHALL BE LAPPED THUS:
BAR LAP LENGTH DOWEL HOOK EMBEDMENT LENGTH
#4 1'-6" 8" #5 2'-0" 10" #6 3'-0" 12"
F.POST INSTALLED ANCHOR BOLTS
1. ANCHOR CAPACITY USED IN DESIGN SHALL BE BASED ON THE TECHNICAL DATA PUBLISHED BY HILTI OR SUCH OTHER METHOD AS
APPROVED BY THE STRUCTURAL ENGINEER OF RECORD. SUBSTITUTION REQUESTS FOR ALTERNATE PRODUCTS MUST BE APPROVED IN WRITING BY THE STRUCTURAL ENGINEER OF RECORD PRIOR TO USE. CONTRACTOR SHALL PROVIDE PUBLISHED DATA DEMONSTRATING THAT THE SUBSTITUTED PRODUCT IS CAPABLE OF ACHIEVING THE PERFORMANCE VALUES OF THE SPECIFIED PRODUCT. SUBSTITUTIONS SHALL BE APPROVED POST-INSTALLED ANCHOR SYSTEMS TESTED TO EITHER ICC AC-193 FOR MECHANICAL ANCHORS OR AC-308 FOR ADHESIVE ANCHORS AND SHALL BE INSTALLED IN ACCORDANCE WITH THE CURRENT ICC ESR REPORT.
2. INSTALL ANCHORS PER THE MANUFACTURER WRITTEN INSTRUCTIONS, AS INCLUDED IN THE ANCHOR PACKAGING. ANCHORS MUST BE
INSTALLED USING THE HILTI PROFIS SYSTEM.
3. THE CONTRACTOR SHALL ARRANGE AN ANCHOR MANUFACTURER'S REPRESENTATIVE TO PROVIDE INSTALLATION TRAINING FOR ALL OF THEIR ANCHORING PRODUCTS SPECIFIED. THE STRUCTURAL ENGINEER OF RECORD MUST RECEIVE DOCUMENTED CONFIRMATION THAT ALL OF THE CONTRACTOR'S PERSONNEL WHO INSTALL ANCHORS ARE TRAINED PRIOR TO THE COMMENCEMENT OF INSTALLING
ANCHORS.
4. ANCHOR CAPACITY IS DEPENDANT UPON SPACING BETWEEN ADJACENT ANCHORS AND PROXIMITY OF ANCHORS TO EDGE OF CONCRETE.
INSTALL ANCHORS IN ACCORDANCE WITH SPACING AND EDGE CLEARANCES INDICATED ON THE DRAWINGS.
5. EXISTING REINFORCING BARS IN THE CONCRETE STRUCTURE MAY CONFLICT WITH SPECIFIC ANCHOR LOCATIONS. IF THIS OCCURS, THE
ENGINEER OF RECORD SHALL BE NOTIFIED.
G.SPECIAL INSPECTIONS
1. SPECIAL INSPECTIONS SHALL BE AS PER IBC CHAPTER 17 "SPECIAL INSPECTIONS AND TESTS", AND ARE PROVIDED HERE, IN PART FOR
REFERENCE.
2. THE OWNER SHALL SELECT A QUALIFIED TESTING/INSPECTION AGENCY AND WILL PAY FOR THE STRUCTURAL TESTING AND SPECIAL
INSPECTION SERVICES THAT ARE REQUIRED BY THE CONTRACT DOCUMENTS.
3. CONTRACTOR SHALL PAY FOR ANY ADDITIONAL STRUCTURAL TESTING/INSPECTION REQUIRED FOR WORK OR MATERIALS NOT COMPLYING
WITH CONTRACT DOCUMENTS DUE TO NEGLIGENCE OR NONCONFORMANCE.
4. CONTRACTOR SHALL PAY FOR ANY ADDITIONAL STRUCTURAL TESTING/INSPECTION REQUIRED FOR HIS CONVENIENCE.
5. THE SPECIAL INSPECTOR SHALL BE A QUALIFIED PERSON WHO MEETS THE REQUIREMENTS OF SECTION 1704 AS FOUND IN THE IBC.
6. THE SPECIAL INSPECTOR SHALL KEEP DAILY RECORDS OF INSPECTIONS AND SHALL PROVIDE MONTHLY WRITTEN REPORTS OF THESE
INSPECTIONS AND TESTS TO THE ENGINEER OF RECORD.
7. ANY TESTS OR INSPECTIONS INDICATING ITEMS NOT IN STRICT CONFORMANCE WITH THE CONTRACT DOCUMENTS AND APPLICABLE
REFERENCED STANDARDS SHALL BE BROUGHT TO THE ATTENTION OF THE CONTRACTOR FOR IMMEDIATE CORRECTION AND DOCUMENTED WITH THE INSPECTOR'S FIELD REPORT. IF THE DISCREPANCIES ARE NOT CORRECTED, THEY SHALL BE BROUGHT TO THE IMMEDIATE
ATTENTION OF THE ENGINEER OF RECORD.
8. THE SPECIAL INSPECTOR SHALL SUBMIT A FINAL STATEMENT OF SPECIAL INSPECTIONS WHICH STATES THAT THE SPECIAL INSPECTIONS AND TESTING REQUIRED FOR THIS PROJECT HAVE BEEN COMPLETED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS.
9. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL WORK IS PERFORMED IN STRICT CONFORMANCE WITH THE CONSTRUCTION DOCUMENTS. A QUALITY CONTROL PROGRAM SHALL BE USED BY THE GENERAL CONTRACTOR. THE SPECIAL
INSPECTIONS SHALL NOT BE USED AS THE CONTRACTOR'S QUALITY CONTROL.
S-001
AGS JRV
STRUCTURAL GENERAL NOTES
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
N/A U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
18300 East 71st Ave., Denver, CO, 80249 504.684.4408; Sean Fitzpatrick
Cedar City, UT
942CM3001
N/A Project Director
Revisions: Date:
Steve Davis Department of Veterans Affairs, NCA
Phone: 202.632.4833 Email: steve.davis@va.gov Sheet of
Environment & Infrastructure Solutions, Inc.
BID DOCUMENTS
VCI Project Management Construction Management Engineering
NATIONAL CEMETERY DEVELOPMENT
CEDAR CITY RURAL INITIATIVE
5/22/2020
National Cemetery Administration
Design and Construction
Service
S-501
S-501
'-0
21'-0"
1' -0
7'
-6
7' -6
1'
-0
1'-0" 7'-6" 7'-6" 1'-0"
6" THICK SLAB ON GRADE
REINF. w/ 6x6-W4xW4, 2" CLR. FROM TOP ON SUPPORT DEVICES
OVER COMPACTED GRANULAR FILL.
REFER TO SECTION 2 & 3 ON DWG S-501
3' -0
3'
-0
3'-0" 3'-0"
SEE NOTE 2 (TYP.)
NOTES:
1. SEE STRUCTURAL GENERAL NOTES FOR ADDITIONAL INFORMATION.
2. PRE-ENGINEERED SHELTER. VENDOR SHALL PROVIDE ANCHOR BOLTS FOR APPROVAL
PRIOR TO CONSTRUCTION.
3. FINAL LOADS FROM PRE-ENGINEERED SHELTER VENDOR SHALL BE PROVIDED TO
VERIFY SHELTER FOUNDATION SYSTEM.
4. REFERENCE CIVIL FOR ACTUAL TOP OF SLAB ELEVATIONS INDICATING SLOPE OF SLAB.
5. CONTRACTOR SHALL RELOCATE UNDERGROUND UTILITIES WITH THE LOCATION OF ALL
FOOTINGS AS REQUIRED.
6. CJ INDICATES CONTROL JOINT. SEE DWG. S-501.
A C
4"
8" CMU BLOCK
(TYP.)
TYP.
S-101
AGS JRV
COMMITTAL SHELTER
FOUNDATION PLAN
T
T
Y
S
B
U
R
G
P
L
A
Q
U
E
BIVOUAC OF THE DEAD
PLAQUE
P A
T R
I O
T I C
S L
O G
A N x
P
C
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
N/A U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
18300 East 71st Ave., Denver, CO, 80249 504.684.4408; Sean Fitzpatrick
Cedar City, UT
942CM3001
N/A Project Director
Revisions: Date:
Steve Davis Department of Veterans Affairs, NCA
Phone: 202.632.4833 Email: steve.davis@va.gov Sheet of
Environment & Infrastructure Solutions, Inc.
BID DOCUMENTS
VCI Project Management Construction Management Engineering
NATIONAL CEMETERY DEVELOPMENT
CEDAR CITY RURAL INITIATIVE
5/22/2020
National Cemetery Administration
Design and Construction
Service
NOTES:
1. REFER TO DWG S-001 FOR STRUCTURAL GENERAL NOTES.
2. VERIFY OVERALL DIMENSIONS OF FOUNDATIONS SHOWN ON THIS DWG MATCH WITH
ARCHITECTURAL & CIVIL DWGS. REFER TO CIVIL DWGS FOR LOCATIONS OF DOUBLE SIDED
COLUMBARIUM, MEMORIAL WALL, RETAINING WALL, AND ORNAMENTAL FENCE.
3. INDICATES STEPPED FOOTING AND ITS DIRECTION IN FOOTING. REFER STEPPED FOOTING
DETAIL ON DWG. S-503 FOR MORE INFORMATION.
4. REFER TO DWG. S-201 FOR ELEVATIONS AT TOP OF FOOTING AND TOP OF STEM WALLS, AND
LOCATIONS OF STEPS IN STEM WALL FOR ORNAMENTAL FENCE.
S-502
S-502
S-502
M A
T C
H L
I N
E
C O
N T
I N
U E
D
B
E L
O W
M A
T C
H L
I N
E
C O
N T
I N
U E
D
A
B O
V E
FRONT OF RETAINING WALL
'-7
2'-0"
64'-0" 5'-0" 27'-4" 5'-0" 34'-7"
4'- 6"
1'-0"
5'- 0"
MEMORIAL WALL FOOTING
REFER TO 4/S-502
4'- 0"
(T
YP
4'- 0"
(T
YP
ORNAMENTAL FENCE FOOTING
REFER TO DWG. S-503 FOR
SECTIONS AND ADDITIONAL INFORMATION
(TYP.)
3'-8"
'-1
1"
5'-0"
'-6
DOUBLE-SIDED
COLUMBARIUM FOOTING
REFER TO 1/S-502
COORDINATE WITH
SITE AND ARCH. (TYP)
5'- 0"
1'-6"
5'- 0"
5'- 0" S-502
22'-0" 9'-11" 4'-5"17'-0" 10'-5" 12'-1" 20'-4" 39'-3" 51'-9" 43'-8"
63'-6"
15'-9"
10'-10"
15'-2"
5'-8"
12'-4"
4'- 0"
(T
YP
5'-6" 7'-9"
26'-0"
14'-0"
13'-4"
16'-0"
11'-11"
14'-1"
12'-8"
10'-3"
ORNAMENTAL FENCE FOOTING
REFER TO DWG. S-503 FOR
SECTIONS AND ADDITIONAL INFORMATION
(TYP.)
5'- 0"
5'- 0"
STEM WALL NOT SHOWN FOR CLARITY,
SEE DWGS. S-201 AND S-503 FOR INFORMATION
ON STEM WALL (TYP.)
STEM WALL NOT SHOWN FOR CLARITY,
SEE DWGS. S-201 AND S-503 FOR INFORMATION
ON STEM WALL (TYP.)
4'- 0"
(T
YP
8'-8"
5'- 0"
5'- 0"
5'- 0"
COORDINATE WITH
SITE AND ARCH.
S-102
AGS JRV
FOUNDATION PLANS
Cedar City
VA National
Cemetery
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
N/A U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
18300 East 71st Ave., Denver, CO, 80249 504.684.4408; Sean Fitzpatrick
Cedar City, UT
942CM3001
N/A Project Director
Revisions: Date:
Steve Davis Department of Veterans Affairs, NCA
Phone: 202.632.4833 Email: steve.davis@va.gov Sheet of
Environment & Infrastructure Solutions, Inc.
BID DOCUMENTS
VCI Project Management Construction Management Engineering
NATIONAL CEMETERY DEVELOPMENT
CEDAR CITY RURAL INITIATIVE
5/22/2020
National Cemetery Administration
Design and Construction
Service
NOTES:
1. TFE INDICATES TOP OF FOOTING ELEVATION
2. TSE INDICATES TOP OF STEM WALL ELEVATION
3. STEPS IN STEM WALL ARE LOCATED AT THE FACE OF
COLUMN VENEER, AND/OR AT 13 POINTS OF TYPICAL 24'-0"
SECTION AS SHOWN, UNLESS NOTED OTHERWISE.
4. REFER TO DWG. S-102 FOR STEP LOCATIONS IN FOOTING.
5. REFER ARCH. DWGS.
19'-6" 16'-0"
7'-0"
2'-8"
10'-0" 12'-0"
8'-9"
8'-8" 5'-4"
10'-3
" 7'-8
SEE NOTE 5
S-201
CAP MJL
ORNAMENTAL FENCE ELEVATION
SKIM COAT OF FINE AGGREGATE BASE ON TOP OF
COMPACTED COARSE AGGREGATE BASE IF SURFACE IS
NOT SMOOTH. ENSURE SURFACE IS SMOOTH AND PLANAR
IMMEDIATELY PRIOR TO PLACING CONCRETE.
SLAB REINFORCING, SEE PLAN.
CONTINUE SLAB REINF. THRU JOINT AT
CONTROL JOINT
USE EARLY ENTRY SAW SYSTEM SAW CUT
"(MAX) WIDE BY
OF SLAB THICKNESS. SAW CUT AS SOON AS CONCRETE
WILL NOT RAVEL (WITHIN 12 HOURS OF SET) FILL JOINT
WITH ELASTOMERIC JOINT SEALANT OVER BACKER ROD
NON-FROST SUSPECTIBLE
AGGREGATE BASE
R E
F
D
T L
C
L R
XXXXXXX
XXXXXXXXXXX
(2) #4 CONT. AT TOP
OF TURN DOWN
#4@12"
T/SLAB
REF. CIVIL
PRE-ENGINEERED SHELTER POST
IN CENTER OF CMU
SLAB REINF.
SEE PLAN
C
L R
(2) #4 AT BOTTOM
OF TURN DOWN
2"CLR.
C
L R
CONTROL JOINT
SEE PLAN
FOR LOCATIONS
2"
VENEER, REF ARCH
NON-FROST SUSCEPTIBLE
MATERIAL/AGGREGATE
1'-0"
2'-0"
GRADE,
REF. CIVIL
ANCHOR CMU TO COLUMN ON
ALL SIDES @ 16" O.C. (TYP.),
FILL ALL CELLS WITH GROUT
SHELTER ANCHORAGE PROVIDED
BY VENDOR. SEE NOTE BELOW
AND NOTE 2 ON DWG. S-101.
NOTE:
CONTRACTOR SHALL ADD SHIMS AND NON-SHRINK GROUT PAD
BELOW BASE PLATE TO LEVEL THE SHELTER AS REQUIRED.
SHIMS AND NON-SHRINK
GROUT AS REQUIRED
XXXXXXXXXXX
(2) #4 CONT. AT TOP
OF TURN DOWN
#4@12"
SLAB REINF.
SEE PLAN
C
L R
(2) #4 AT BOTTOM
OF TURN DOWN
2"CLR.
C
L R
CONTROL JOINT
SEE PLAN
FOR LOCATIONS
2"
T/SLAB
REF. CIVIL
VENEER,
REF ARCH
#5 @ 32" IN FULLY
GROUTED CELLS
1'-0"
NON-FROST SUSCEPTIBLE
MATERIAL/AGGREGATE
2'-0"
GRADE,
REF. CIVIL
SLAB REINF.
SEE PLAN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
N/A U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
18300 East 71st Ave., Denver, CO, 80249 504.684.4408; Sean Fitzpatrick
Cedar City, UT
942CM3001
N/A Project Director
Revisions: Date:
Steve Davis Department of Veterans Affairs, NCA
Phone: 202.632.4833 Email: steve.davis@va.gov Sheet of
Environment & Infrastructure Solutions, Inc.
BID DOCUMENTS
VCI Project Management Construction Management Engineering
NATIONAL CEMETERY DEVELOPMENT
CEDAR CITY RURAL INITIATIVE
5/22/2020
National Cemetery Administration
Design and Construction
Service S-501
AGS JRV
COMMITTAL SHELTER DETAILS
C
L
C
L
ROUGHEN
CONCRETE
(TYP.)
(3)-#5 CONT. BOTTOM REBAR
#5@12"O.C. MAX
#4@12"O.C.
THIS FACE (TYP.)
#4 @ 12"O.C. MAX
CONT. SIDE REBAR E.F.
T/FTG EL.=6045.50'
NOTES:
1. STEP STONE LEDGE IN 12" VERTICAL
INCREMENTS THEN RUN STEP HORIZONTAL
UNTIL MIN. 4" COVER TO GRADE LINE IS MET
AT ENDS OF WALL.
(4)-#5 CONT.
TOP REBAR
M I N
V A
R I E
S
S
N
O T
E
9" 9" 1'-0"
2'-0"
V A
R I E
S
3"CLR.
C L R
4"
4"
FASTEN STONE VENEER
TO CONC. (TYP.)
STONE CAP
EXP. JOINT
FILLER
W/ SEALER
FRONT OF WALL
T / PLAZA
REF. CIVIL
#5@12"O.C.
THIS FACE
(TYP.)
C L A
S S
B
L A
P
S
P L I C
E
T
Y P
" CLR.
(TYP.)
DRAIN BY CIVIL
T/WALL EL.= 6055.35'
4" 4"
8" 2'-4" 8"
3'-8"
#5 TIES 12" O.C. MAX
#6 @ 8" O.C. MAX
#5 @ 12"
ROUGHEN
CONCRETE
(4)-#5 CONT.
#5 @ 12" EA. SIDE
C L R
STONE CAP
1'-8"
#5 @ 32" O.C.
GROUT CELL FULLY
DOWEL TO
MATCH WALL REINF
HORIZONTAL
LADDER-TYPE TIES
@16" O.C.(TYP.)
ANCHOR BOLT. REFER ARCH.
#5 TIES 12" O.C. MAX
#6 @ 8" O.C. MAX
#5 @ 12"
#5 @ 12" EA. SIDE
8" 3'-8" 8"
5'-0"
ROUGHEN CONCRETE
(6)-#5 CONT.
4" 3'-0" 4"
ANCHOR BOLT RECESSED
MINIMALLY. REFER ARCH.
TOP OF SIDEWALK
EXP. JT. FILLER
WITH SEALANT
STONE CAP
FASTEN STONE VENEER
TO MASONRY, (TYP.)
HORIZONTAL
LADDER-TYPE TIES
@16" O.C.(TYP.)
S-502
#5 REBAR
DOWEL TO
MATCH WALL REINF
4" 8"
#5 FULL HEIGHT
IN FULLY
GROUTED CELL
S-502
TOP OF SIDEWALK
EXP. JT. FILLER
WITH SEALANT
STONE CAP
FASTEN STONE VENEER
TO MASONRY, (TYP.)
HORIZONTAL
LADDER-TYPE TIES @16"
O.C.(TYP.)
4" 8"
#5 FULL HEIGHT
IN FULLY
GROUTED CELL
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
N/A U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
18300 East 71st Ave., Denver, CO, 80249 504.684.4408; Sean Fitzpatrick
Cedar City, UT
942CM3001
N/A Project Director
Revisions: Date:
Steve Davis Department of Veterans Affairs, NCA
Phone: 202.632.4833 Email: steve.davis@va.gov Sheet of
Environment & Infrastructure Solutions, Inc.
BID DOCUMENTS
VCI Project Management Construction Management Engineering
NATIONAL CEMETERY DEVELOPMENT
CEDAR CITY RURAL INITIATIVE
5/22/2020
National Cemetery Administration
Design and Construction
Service
S-502
S-502
S-502
S-502
S-502
AGS JRV
COLUMBARIUM, AND WALLS
STRUCTURAL DETAILS
26'-0"
8'-0" 8'-0" 8'-0"
26'-0"
8'-0" 8'-0" 8'-0"
1'-4"
1'- 4"
4"4"
4" 4"
26'-0"
8'-0" 8'-0" 8'-0"
1'-4"
1'- 4"
4"4"
4" 4"
#6 @ 24" FULL HEIGHT
IN FULLY GROUTED CELL,
DOWEL INTO STEM WALL
#5 FULL HEIGHT AT COLUMNS
(4 TOTAL) IN FULLY
GROUTED CELLS,
DOWEL INTO FOOTING.
GROUT ALL CELLS
#5 FULL HEIGHT AT COLUMNS
(4 TOTAL) IN FULLY
GROUTED CELLS,
DOWEL INTO FOOTING.
GROUT ALL CELLS
HORIZ. REINFORCEMENT
FENCING, REFER ARCH.
2'-0"
6'- 0"
M
IN
VA
RI
ES
VA
RI
ES
2'-0"
VA
RI
ES
1'-
2"
#5@12" O.C.
(TYP.)
#5@12" O.C.
(4)-#5@12"O.C.
T/GRADE
REF CIVIL
T/STEM WALL
REF S-201
T/FOOTING
REF S-201
SEE DWG. S-102
COBBLESETONE
REFER ARCH.
2'-0"
6'- 0"
M
IN
VA
RI
ES
VA
RI
ES
2'-0"
VA
RI
ES
1'-
2"
2'-0"
6'- 0"
M
IN
VA
RI
ES
VA
RI
ES
2'-0"
VA
RI
ES
1'-
2"
2'-0"
6'- 0"
M
IN
VA
RI
ES
VA
RI
ES
2'-0"
VA
RI
ES
1'-
2"
#5@12" O.C.
(TYP.)
#5@12" O.C.
(5)-#5@12"O.C.
#5@12" O.C.
(TYP.)
#5@12" O.C.
(4)-#5@12"O.C.
#5@12" O.C.
(TYP.)
#5@12" O.C.
(4)-#5@12"O.C.
T/GRADE
REF CIVIL
T/GRADE
REF CIVIL
T/GRADE
REF CIVIL
T/STEM WALL
REF S-201
T/FOOTING
REF S-201
T/STEM WALL
REF S-201
T/FOOTING
REF S-201
T/STEM WALL
REF S-201
T/FOOTING
REF S-201
SEE NOTE
BELOW
SEE DWG. S-102 SEE DWG. S-102 SEE DWG. S-102
COBBLESTONE
REFER ARCH. COBBLESTONE
REFER ARCH.
COBBLESTONE
REFER ARCH.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
N/A U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
18300 East 71st Ave., Denver, CO, 80249 504.684.4408; Sean Fitzpatrick
Cedar City, UT
942CM3001
N/A Project Director
Revisions: Date:
Steve Davis Department of Veterans Affairs, NCA
Phone: 202.632.4833 Email: steve.davis@va.gov Sheet of
Environment & Infrastructure Solutions, Inc.
BID DOCUMENTS
VCI Project Management Construction Management Engineering
NATIONAL CEMETERY DEVELOPMENT
CEDAR CITY RURAL INITIATIVE
5/22/2020
National Cemetery Administration
Design and Construction
Service
S-503
7 OR 8
S-503
S-503
7 OR 8
S-503
7 OR 8
TYP.
S-503
NOTES:
1. REFER TO ARCHITECTURAL DRAWINGS FOR ADDITIONAL ORNAMENTAL FENCE DETAILS.
2. REFER TO DWG. S-201 FOR ELEVATIONS OF CONCRETE COMPONENTS.
WALL REINF.
WHERE APPLICABLE
2'-0"
T
1'-0"
T
DOWELS TO MATCH
CONT. FOOTING REINF.
#5 EACH FACE
LAP SPLICE
LAP
SPLICE
2'- 0"
MA
X
NOTE
'T' INDICATES THICKNESS OF FOOTING, SEE DETAIL 5-7/S-503
12" CMU BLOCK OR
8" & 4" CMU BLOCKS,
SEE NOTE BELOW
CONTRACTOR'S OPTION:
AT LOCATIONS WHERE PROPOSED GRADE OF NORTHERN SIDE OF FENCE IS 8" OR
HIGHER THAN THE OTHER SIDE, UTILIZE 12" WIDE CMU BLOCK OR 8" AND 4" CMU
BLOCKS FOR STONE VENEER TO BEAR ON INSTEAD OF CONCRETE STEM WALL.
MAINTAIN MIN. 6" COVER OF GRADE OVER TOP OF CONCRETE STEM WALL.
CONTRACTOR'S OPTION:
AT LOCATIONS WHERE THE PROPOSED GRADE IS 6" OR HIGHER ON BOTH SIDES THAN
THE CMU BLOCK(S), UTILIZE 4" WIDE CMU BLOCKS ON BOTH SIDES IN PLACE OF THE
STONE VENEER. MAINTAIN MIN. 6" COVER OF GRADE OVER TOP OF CONCRETE STEM
WALL.
TYP.
S-503
S-503
AGS JRV
ORNAMENTAL FENCE
STRUCTURAL DTLS
HOOK BARS INTO BOND BEAM
GROUT CELLS
FULL HEIGHT AT
REINFORCEMENT
(TYP.)
REINFORCEMENT,
SEE PLANS AND SECTIONS
FOUNDATION
S P
L I C
E
B
A R
S
R E
F
S
S P
L I C
E
B
A R
S
R E
F
S
CONT. BOND BEAM
WITH (2)-#5 CONT.
(TYP.)
SEE PLAN
(2)#5 (1 EA CELL) @ 8" CMU,
AT EACH END OF WALL
SEE PLAN
FOUNDATION,
SEE PLAN
NOTES:
1. ALL BARS TO DOWEL 11" MIN. INTO
FOUNDATION OR CONC. WALL WITH
STANDARD HOOK - BAR TO PROJECT (1) BAR
LAP LENGTH ABOVE FOUNDATION OR WALL -
ALL BARS TO RUN CONT. THROUGH BOND
BEAM.
HORIZ. JOINT REINF. @ 16" O.C.
DOWELS TO MATCH
VERTICAL WALL REINF.
LAP BARS PER SCHEDULE
T/ BOND BEAM
AT 4'-0"
16" MAX
SPACING
SEE SECTIONS
FOR REINFORCING DETAILS
MAXIMUM SPACING
TO BE 24" O.C.
M
X
R O
U
I F
T
L A
P
S
P L
I C
E
B
A R
S
P E
R
S
C H
E D
U L
E
L A
P
S
P L I C
E
P E
R
S C
H E
D U
L E
T
Y P
M
X
R O
U
F
T
L A
P
S
P L
I C
E
B
A R
S
P E
R
S
C H
E D
U L
E
G
R O
U T
L I F
T
MAX SPACING
T/ BOND BEAM
AT 4'-0"
MAX SPACING
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
N/A U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
18300 East 71st Ave., Denver, CO, 80249 504.684.4408; Sean Fitzpatrick
Cedar City, UT
942CM3001
N/A Project Director
Revisions: Date:
Steve Davis Department of Veterans Affairs, NCA
Phone: 202.632.4833 Email: steve.davis@va.gov Sheet of
Environment & Infrastructure Solutions, Inc.
BID DOCUMENTS
VCI Project Management Construction Management Engineering
NATIONAL CEMETERY DEVELOPMENT
CEDAR CITY RURAL INITIATIVE
5/22/2020
National Cemetery Administration
Design and Construction
Service
S-504
S-504
AGS JRV
TYPICAL MASONRY DETAILS
N E
L
L A
B
I N
J
C
J
A
C
J
OM3
CAMERA
POWER
SUPPLY
CAT 6
CAT 6
ALL IN ONE CAMERA APPLIANCE
AVIGILON 8 PORTS 8TB OR EQUAL
IDF RM
PUMP HOUSE
19"
RG-59U
CAT 6
SPD
1U RACK- MOUNT
CONSOLE
G
E
T
T
Y
S
B
U
R
G
P
L A
Q
U
E
B
I
V
O
U
O
F
H
D
A
D
P
L
A
Q
U
E
P
A
T
R
I
O
T
I
C
S
L
O
G
A
N
S
J
NEW WORK KEY NOTES:
240/120V 1-P PANEL LA1. REFER TO SHEET E-601 FOR ADDITIONAL
INFORMATION.
240/120V 1-P PANEL LC1. REFER TO SHEET E-601 FOR ADDITIONAL
INFORMATION.
GATE MOTOR AND CONTROLLER POWERED FROM PANEL LC1.
J-BOX FOR CONNECTION OF SECURITY DEVICES POWERED FROM
LC1.
240/120V 1-P PANEL LB1. REFER TO SHEET E-601 FOR ADDITIONAL
INFORMATION.
GATE MOTOR AND CONTROLLER POWERED FROM PANEL LB1.
J-BOX FOR CONNECTION OF SECURITY DEVICES POWERED FROM
LB1.
ADDITIONAL GATE #2 MOTOR. SEE SHEET E-601 FOR ADDITIONAL
INFORMATION.
ADDITIONAL GATE #1 MOTOR. SEE SHEET E-601 FOR ADDITIONAL
INFORMATION.
CARD READER (ELKA 1100 STANDARD ACCESS CONTROL
COLUMNS OR EQUAL).
IT EQUIPMENT RACK (TRIPP LITE HEAVY DUTY SRW18UHD OR
EQUAL).
CAMERA POLE (CAMERA.POLES 20FT STEEL ROUND CAMERA OR
EQUAL).
STEEL BOLLARD DEVICE PROTECTION (SEE DETAIL 8).
FOUR BOLLARDS EACH LOCATION, IN A 2'W*3'L RECTANGULAR
CONFIGURATION TO PROTECT CARD READERS (SEE SHEET A-512).
COMMUNICATION PLAN- PUMP HOUSE
LB1, CKT- 2, 4
LB1, CKT- 1
LC1, CKT- 1
LC1, CKT- 2, 4
COMMUNICATION PLAN - GATE #1
LB1, CKT- 6
LC1, CKT- 6
GENERAL NOTES:
1. ANY WORK RELATED TO THE POWER LINES WILL NEED TO BE
COORDINATED WITH THE LOCAL ELECTRICAL UTILITY (ROCKY
MOUNTAIN POWER). CONTACT: MARK LEWIS AT (435) 865-3343.
PTZ EXTERIOR POLE MOUNTED CAMERA DETAIL
VEHICLE PEDESTAL DEVICE DETAIL
CCTV SYSTEM RISER DIAGRAM
COMMUNICATION PLAN-SITE
OUTDOOR
CAMERA
WITH NIGHT
VISION
COMMUNICATION PLAN - GATE #2
NOTES:
1. PROVIDE POWER FOR ALL OUTDOOR CAMERAS. OUTDOOR CAMERAS
SHALL BE PTZ (PAN-TILT-ZOOM)TYPE WITH NIGHT VISION.
2. CAMERAS SHALL BE MOUNTED +12'-0" AFF.
3. PROVIDE HEATER AND OUTDOOR ENCLOSURE FOR ALL OUTDOOR
CAMERAS.
4. SEE SPECIFICATIONS FOR ADDITIONAL DETAILS.
CAMERA ON INTERIOR WALL
SEE PLANS (TOTAL 1 CAMERA)
CAMERAS ON POLES
ON SITE (TOTAL 3 CAMERAS)
OUTDOOR PTZ DOME CAMERA
PTZ CAMERA ENCLOSURE SHALL
HOUSE ALL EQUIPMENT INCLUDING
HEATER AND RELATED CIRCUITRY.
POE (CAT6) CABLING RUN
INSIDE POLE IN SEPARATE
COMPARTMENT OR CONDUIT
BY THE CONTRACTOR
THE CONTRACTOR SHALL BE
RESPONSIBLE FOR PROVIDING ALL
NECESSARY BRACKETS AND
ACCESSORIES FOR INSTALLING THE
CAMERA ASSEMBLY SECURELY TO
THE POLE AT 22 FEET OR 18
FEET ABOVE BASE
LOCKABLE NEMA 4 ENCLOSURE ON THE
POLE BY THE CONTRACTOR. PROVIDE A
120VAC DUPLEX INSIDE THE NEMA BOX.
CAMERA POWER SUPPLY, CAT6 MEDIA
CONVERTER,MEDIA CONVERTER POWER
SUPPLY AND SURGE SUPPRESSORS
SHALL BE PROVIDED INSIDE THE NEMA BOX.
CONCRETE PEDESTAL 4000 PSI
GRADE
OM3 FIBER CABLING RUN IN
CONDUIT PROVIDED BY
DIVISION 27
CAT6 CABLING TO THE
GATE PEDESTAL INTERCOM
PROVIDE BY DIVISION
27. REFER TO THE
TELECOMMUNICATION
DRAWINGS FOR FURTHER
INFORMATION.
CARD READER CABLING
TO THE GATE PEDESTAL
PROVIDED BY THE
CONTRACTOR.
WEATHER SHIELD
BACK BOX
1" CONDUIT TO THE VEHICLE
PEDESTAL. REFER TO THE
FLOOR PLAN DRAWINGS FOR
EXACT LOCATION.
CARD READER (REFER TO
THE TELECOMMUNICATION
FLOOR PLAN DRAWINGS
FOR EXACT EQUIPMENT
REQUIREMENTS)
ACCESS CONTROL RACK
STEEL BOLLARD DETAIL
MIN. DIA.
SET POST IN CONCRETE
FINAL GRADE
6' DIAMETER STEEL
PIPE FILLED WITH CONCRETE
AND PAINTED FLUORESCENT
ORANGE
1" SMOOTH CROWN
3'-0"
2'-0"
1'-0"
2'-6"
1'-0"
FOUNDATION REQUIREMENTS FOR
CARD READERS ARE TO BE CONSTRUCTED
WITH A SINGLE PIER FOUNDATION
CONSTRUCTION PER DETAILS
C2 & D2/A510.
FOUNDATION REQUIREMENTS FOR
CAMERA POLES ARE TO BE CONSTRUCTED
WITH A SINGLE PIER FOUNDATION
CONSTRUCTION PER DETAILS
C2 & D2/A510.
T-101
TEL-COMMUNICATION PLAN
AND DETAIL
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID…