This federal contract opportunity solicitation seeks a contractor to remodel specialty care and correct HVAC systems in Building 19 at the Martinez VA Medical Center. The selected contractor shall provide all labor, materials, equipment, supervision and other resources necessary to complete the construction project according to the specifications and drawings in Attachment 5, Volume 3. The solicitation was issued by the Department of Veterans Affairs Technology Acquisition Center Austin as number 36C77621B0021. The contractor must remodel specialty care areas and correct HVAC systems to address needs at the Martinez VAMC facility.

View the file

Other files

File Type Posted
S05 - Att 08e - Existing Equipment (5).jpg JPG image
S05 - Att 08b - Existing Equipment (2).jpg JPG image
S05 - Att 04 - 19_Martinez Floor Plan.pdf PDF
S05 - Att 03 - ICRA_ICCP -- Final.pdf PDF
S05 - Att 08g - Existing Equipment (7).jpg JPG image
S05 - Att 07g - CAD Files - Plumbing (7).zip ZIP file
S05 - Att 07b - CAD Files - Architectural (2).zip ZIP file
S05 - Att 08h - Existing Equipment (8).jpg JPG image
S05 - Att 07f - CAD Files - Mechanical (6).zip ZIP file
S05 - Att 07d - CAD Files - Electrical (4).zip ZIP file
S05 - Att 06 - VAV Pipe Detail.zip ZIP file
S05 - Att 02 - Nurse Call Cut-Sheets Request.pdf PDF
36C77621B0021 0003.pdf PDF
S05 - Att 08d - Existing Equipment (4).jpg JPG image
S05 - Att 07c - CAD Files - Structural (3).zip ZIP file
S05 - Att 07a - CAD Files - Architectural (1).zip ZIP file
S05 - Att 07b - CAD Files - Structual.zip ZIP file
S05 - Att 07e - CAD Files - Fire Protection (5).zip ZIP file
S05 - Att 05 - Martinez B19_RxR_220908.xlsx XLSX spreadsheet
S05 - Att 08a - Existing Equipment (1).jpg JPG image
S05 - Att 08i - Existing Equipment (9).jpg JPG image
S05 - Att 08c - Existing Equipment (3).jpg JPG image
S05 - Att 01 - Technical Questions and Answers 9.9.2022.pdf PDF
S05 - Att 08f - Existing Equipment (6).jpg JPG image
S05 - Att 09 - CAD Files - Chaparral Layouts.zip ZIP file
36C77621B0021 0002.pdf PDF
S04 - Site Visit - Sign-in Sheet.pdf PDF
S06 - SF30 - 36C77621B0021 - Amendment 0001.pdf PDF
S02 - ATTACHMENT 2 - Specifications Vol. 2 of 2.pdf PDF
S02 - ATTACHMENT 9 - Construction Wage Rates.pdf PDF
36C77621B0021.pdf PDF
S02 - ATTACHMENT 10 - Contractor Safety - Environmental Form.docx DOCX document
S02 - ATTACHMENT 8 - Limitations on Subcontracting - Construction.docx DOCX document
S02 - ATTACHMENT 4 - Drawings Vol. 2 of 3.pdf PDF
S02 - ATTACHMENT 6 - Contractor Core Work Hours.pdf PDF
S02 - ATTACHMENT 7 - COVID-19 Safety Protocols 12-14-21.pdf PDF
S02 - ATTACHMENT 3 - Drawings Vol. 1 of 3.pdf PDF
S02 - ATTACHMENT 1 - Specifications Vol. 1 of 2.pdf PDF
Show all 38

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

E

F

G

H

J

K

L

M

N

P

Q

R

S

T

U

V

PHASE 1 - 2ND FLOOR BELOW

CONSTRUCTION

1 2 3 4 5 6 7 8

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

ARCHITECT OF RECORD

BI

M

M ar tin ez B

/6

-1

8-

9_ A.

rv t

2/ 9/

:0

0:

P M

CONCOURSE FEDERAL GROUP

213 SOUTH ROYAL STREET

ALEXANDRIA, VA 22314

GENE KLOW

REMODEL SPECIALTY

CARE - BUILDING 19

VA MARTINEZ

612-18-329

03/26/2021

100% - BID SET

Revisions: Date:

CONSULTING ENGINEERS

F.W. A NC.SSOCIATES,I

SJ/MF FWA TEAM

ES3-4

ROOF PLAN - ELECTRICAL

GENERAL NOTES

ROOF PLAN - ELECTRICAL1

SHEET NOTES

KEY PLAN

Roof N

4 4 8 12 16 20 1/8" = 1'-0"

FEETSCALE

AutoCAD SHX Text

(N) EF-12

AutoCAD SHX Text

(E) AHU-4

AutoCAD SHX Text

(E) EF-16

AutoCAD SHX Text

(E) EF-26

AutoCAD SHX Text

(E) AHU-3

AutoCAD SHX Text J

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text

LCC2-35,37,39

AutoCAD SHX Text

520 3RD STREET, SUITE 206, OAKLAND, CA 94607

AutoCAD SHX Text

PHONE: (510) 763-7475

AutoCAD SHX Text

FAX: (510) 763-7033

AutoCAD SHX Text No.10436

AutoCAD SHX Text Exp.9-30-2022

AutoCAD SHX Text

1. EXISTING ELECTRICAL DEVICES SHOWN ON EXISTING ELECTRICAL DEVICES SHOWN ON THIS DRAWING ARE BASED ON INFORMATION PROVIDED BY VA AND VISUAL SITE INSPECTION. CONTRACTOR SHALL COORDINATE WITH ALL DISCIPLINES PRIOR TO DEMOLITION. CONTRACTOR SHALL DISCONNECT AND REMOVE ALL ELECTRICAL DEVICES SHOWN ON DRAWING COMPLETE WITH ALL ASSOCIATED CONDUIT AND WIRING BACK TO PANEL OF ORIGIN.

AutoCAD SHX Text

SCALE: 1/8"=1'-0"

AutoCAD SHX Text DISCONNECT AND REMOVE EXISTING CIRCUIT WIRING TO EXISTING EXHAUST FAN. CONNECT NEW CIRCUIT TO NEW EF-12. PROVIDE 3#12 + 1#12 GROUND IN 3/4" CONDUIT.

5 6 7

N

P

Q

R

S

T

U

V

1A

/A 208 SF

(E)

PRESCRIPTION

RECEIVING

/A 256 SF

(E)

PRESCRIPTION

RECEIVING

/A 120 SF

1---

(E) EXAM

/A 121 SF

(E) OFFICE

/A 133 SF

(E) OFFICE,

SUPERVISORY

PHARMACIST

/A 172 SF

(E) STORAGE,

CONTROLLED

SUBSTANCES,

SECURED

DISPENSING

/A 325 SF

(E)

DISPENSING

/A 113 SF

B132

PC EXAM

EXPA1

/A 64 SF

B131

LAB/PC TOILET

TLTU1

/A 127 SF

B146

PC EXAM

EXPA1

/A 124 SF

B145

PC EXAM

EXPA1

/A 87 SF

B143E

(E) ANTE

ROOM

VESTIBULE

/A 51 SF

B143G

(E) AIRLOCK

/A 62 SF

B143H

(E) CHEMO

HOOD ROOM

/A 50 SF

B143I

(E) IV BUFFER

/A 105 SF

B143F

(E) ANTE

ROOM

/A 47 SF

B180

HAC

JANC1

F0205

E0948

M9035

E0948

F2010

M9035

M7401

E0948

M3150AR

M3070

E0948

F0340

F0340A F0340A F0340A F0340A

F3200

F3200

F2010A

A5082

M4116

A5075

A5075

A5075

A5075A

A5075

A5075

A5145

M4116

M4100 M4200

A5180

M4116 F0340

M9035

A5145

F0340

M4255

F0340

M4116 M8810

M9100

M7401

M3070

F0340 F2010A

M9035

M4100 M4200

F3200

M4200 M4100A5145

F0340

M4116

A5107A F0340

M4116

A5180

A5082

A5075

F2010A

A5180

M9035

M4116

E0948

M7401

M4100 M4200

A1015

M7401

A5180

M7401

M7401

A5082

A5082

F0713

A1015

F0713

A1015

F0713

A1015

F0713A1015

A5180

P1965

A5075

A1067

A5082

A5082

A5082

A5180

A5082

A5077

A5077 A5077

A5225

M1801 M1800

A5225 M1801 M1800

A5225 M1801 M1800

M1801 M1800 A5225

A5077

A5077

F2010 /A 83 SF

B175

WS CONSULT

OFDC2

/A 116 SF

B143A

PC EXAM

EXPA1

/A 112 SF

B144A

PC Exam

EXPA1

/A 117 SF

B144

PC EXAM

EXPA1

/A 121 SF

B143

PC EXAM

EXPA1

/A 82 SF

B170

WS WAITING

WRC01

/A 350 SF

B130

BLOOD DRAW

LBVP1

F2010A

F0705A

/A 225 SF

B171

WS

PROCEDURE

TRPR1

/A 41 SF

B172

SOILED

UTILITY

USCL1

/A 47 SF

B171A

WS TOILET

TLTB1

/A 117 SF

B173

WS EXAM

EXPA1

/A 56 SF

B174

WS TOILET

TLTU1

F0280 F0280

A5225 M1800 M1801

A1015

F0340

M9035

M7401

M4116

F2010A A5082

A5077

A5075A

M4020

M3150A

A5109

A5202

A5109 P9051

A5090 A5202

M9035

M7401E0948

F0340 F0280

M1801 M1800

F0713

A5225

A5082

F2010A

F0465A

F0465

F0280

A5225 F0713

M1800 M1801

M3072

F3200

F0210A

A5075 A5075A M4100

M4200

A5077

A5145 F2010

F2010 A5109 P9051

A1067

A5107A

F2010A

A1015

A1015

F2000

A5082A5202 A5090

R6200A

A5075

A5082 A5075

M4100

A5107A

F0340

A5145

A6046B

F2010

A5075

A5082

A1067

P3200

P3200

P3200 F0280

F0750A

F0280

F0713

M1800 A5225 M1801

F0280

A5077

A5077

A5077

A5077

A5077

F2010A

A5075

A6046D

A6046D

A5145

A6046DA6046D A6046D

F0280

A5145

A5075 A5075A

A5082 F2010A

F0280

A1015 F0713A5225

M1800 M1801

M7401 M4200

F3200 M4100

M9035 M4116

E0948

A5180

A1015 A5225 M1800 M1801

A5075A

F3200

F0340

A5075 A5075A

A5145

A5077M4116

M4100

M9035M7401

F0713

A1015 A5225

M1801 M1800

F0280

A5082

M4100 M4200

A5145A5145

M4100 M4200 F3200

F0713

E0948

A5075

A5075AA5075A

A5075A

A5075A

F0280

A5145

F0280

F2010A

A5075A

A5075

A5077 A1017

F2010A A5075A

A1032

F2010A

F0115AP4700

A5077

A5180

A5107A

A5107A

A5107A

A5107A

A5107A

/A 116 SF

B133

PC EXAM

EXPA1

A5107A F3200

E0948

L1200

A5090 A5145

F2300

A5145 A5145

A5077

A5108

A5108

A5108

A5108

A5108A5108

A5108

A5108

A5108 A5108

F3200

E0257B

E0257B

E0257B

E0257B

E0257C

E0257C

E0257C

E0257C

E0257C

E0257C

/A 119 SF

1074A

CORRIDOR

E0948

E0948A

E0948A E0948A

E0948A

F3200

A5082

M3072

A5145

/A 230 SF

B145B

TEAM ROOM

WRTM1

F0225

R7250

F0795

F0225

F0225

A5077

F2026A

U1006 U1005

CT020A

CS010A

C04Q0A

K1552

K4665A K4665

F3050

M1801

A1015

F0280 F0280

A1015

F2000

F0713 F0713

M1800 A5225 A5225

M1800 M1801

F0280

A1015

F0713

F3050F3200 A5077

A1015 F0713

F0280

A5225 M1800 M1801

F0280 F0280

A1015

F0713

A5225A5225 M1800 M1800

M1801M1801

M1840

A5145

F0740 F2000

F0280

F2300

CT020

A5082 A5075

F0206

F0206

F0206

F0206

F0206

F0206

F0206 F0206

F0206

F0206

/A 101 SF

CORRIDOR

/A 99 SF

CORRIDOR

F3050A

F3050A

F3050A

F3050A

F3050A

F3050A

F3050A

F3050A

F3050A

F3050A

/A 57 SF

B170A

RECEPTION/GREETER

RECP1A6046A

F2000 F0410 F0420

A6046A

A6046D

M1801 A5225A

A1015

F0713A

A6046A

A5180

A5180

F0225 A1015

F0713

A5225 M1801 M1800

A6046A A6046A

A6046A

A6046A

A6046A

A6046A

A6046A

A6046A A6046A

A6046A

A6046A

P9051

F3200

A6046A

A6046A

F0420A

F0713

R.2

F3200

A5180

A5077

A5077

F3200

F3200

F3050

F3200

F0206A F0205A

F0205A

F0205A

M4200

P3200

M4200

A5075A

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

ARCHITECT OF RECORD

BI

M

M ar tin ez B

/6

-1

8-

9_ A.

rv t

2/ 9/

:0

0:

P M

CONCOURSE FEDERAL GROUP

213 SOUTH ROYAL STREET

ALEXANDRIA, VA 22314

GENE KLOW

REMODEL SPECIALTY

CARE - BUILDING 19

VA MARTINEZ

612-18-329

03/26/2021

100% - BID SET

Revisions: Date:

CONSULTING ENGINEERS

F.W. A NC.SSOCIATES,I

SJ/MF FWA TEAM

ES4-1

PHASE 2 FIRST FLOOR -

FIRE ALARM

RISER DIAGRAM

FIRE ALARM SYSTEM

PHASE 2 FIRST FLOOR - POWER

FIRE ALARM SYSTEM GENERAL NOTES

N

2 2 4 6 8 10 1/4" = 1'-0"

FEETSCALE

KEY PLAN

Floor 1

RISER DIAGRAM NOTES:

FIRE ALARM SHEET NOTES

VA PLAN CHECK NOTES

AutoCAD SHX Text

AutoCAD SHX Text

(TYP)

AutoCAD SHX Text

520 3RD STREET, SUITE 206, OAKLAND, CA 94607

AutoCAD SHX Text

PHONE: (510) 763-7475

AutoCAD SHX Text

FAX: (510) 763-7033

AutoCAD SHX Text No.10436

AutoCAD SHX Text Exp.9-30-2022

AutoCAD SHX Text

EOL

AutoCAD SHX Text

EOL

AutoCAD SHX Text

END OF LINE

AutoCAD SHX Text

END OF LINE

AutoCAD SHX Text 1.

AutoCAD SHX Text THE FIRE ALARM SYSTEM IS DESIGN BUILD AND THE CONTRACTOR SHALL NEED TO PROVIDE ALL DEVICES AS REQUIRED PER CODE AND NEED TO SUBMIT SHOP DRAWING AND SUBMITTAL FOR REVIEW AND APPROVAL.

AutoCAD SHX Text 2.

AutoCAD SHX Text

ALL FIRE ALARM DEVICES ARE NEW UNLESS NOTED AS (E) EXISTING OR (RL) RELOCATE.

AutoCAD SHX Text

(E) FIRE ALARM TERMINAL CABINET /CONTROL PANEL IN ROOM A202

AutoCAD SHX Text 3.

AutoCAD SHX Text

SEE FLOOR PLAN FOR QUANTITY OF FIRE ALARM DEVICES.

AutoCAD SHX Text

SCALE: 1/4"=1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

1. CONTRACTOR SHALL PROVIDE COMPLETE FIRE ALARM SHOP CONTRACTOR SHALL PROVIDE COMPLETE FIRE ALARM SHOP DRAWING SUBMITTALS FOR VA REVIEW AND APPROVAL. SHOP DRAWINGS SHALL INCLUDE BUT NOT LIMITED TO THE FOLLOWING: a) ALL FIRE ALARM DEVICE LOCATIONS ALL FIRE ALARM DEVICE LOCATIONS b) POINT TO POINT WIRING DIAGRAM POINT TO POINT WIRING DIAGRAM c) WIRING SIZE AND CONDUIT SIZE WIRING SIZE AND CONDUIT SIZE d) BATTERY CALCULATION BATTERY CALCULATION e) VOLTAGE DROP CALCULATION VOLTAGE DROP CALCULATION f) ALL FIRE ALARM EQUIPMENT PART NUMBERS ALL FIRE ALARM EQUIPMENT PART NUMBERS g) TIE IN AND CONNECTIONS BETWEEN EXISTING BUILDING FIRE TIE IN AND CONNECTIONS BETWEEN EXISTING BUILDING FIRE ALARM SYSTEM AND NEW FIRE ALARM EQUIPMENT AND DEVICES. 2. CONTRACTOR SHALL PROVIDE ALL MATERIAL AND LABOR AS CONTRACTOR SHALL PROVIDE ALL MATERIAL AND LABOR AS REQUIRED FOR A COMPLETE OPERABLE FIRE ALARM SYSTEM. 3. CONTRACTOR SHALL PROVIDE ALL NEW FIRE ALARM DEVICES, CONTRACTOR SHALL PROVIDE ALL NEW FIRE ALARM DEVICES, SPEAKER STROBES, RELAYS, TRANSMITTERS, ETC. AS REQUIRED FOR A COMPLETE FIRE ALARM SYSTEM. ALL NEW FIRE ALARM EQUIPMENT AND DEVICES SHALL BE COMPATIBLE WITH EXISTING BUILDING FIRE ALARM SYSTEM. 4. NEW FIRE ALARM SYSTEM SHALL BE COMPATIBLE WITH NEW FIRE ALARM SYSTEM SHALL BE COMPATIBLE WITH EXISTING BUILDING FIRE ALARM SYSTEM. 5. FIRE ALARM SYSTEM SHALL MEET ALL CURRENT NEC AND FIRE ALARM SYSTEM SHALL MEET ALL CURRENT NEC AND NFPA REQUIREMENTS. 6. CONTRACTOR SHALL PROVIDE ALL NECESSARY PROGRAMMING CONTRACTOR SHALL PROVIDE ALL NECESSARY PROGRAMMING AND TESTING BETWEEN EXISTING BUILDING FIRE ALARM AND NEW FIRE ALARM EQUIPMENT AND DEVICES. PROVIDE ADDITIONAL DEVICE MODULES, RELAY MODULES, BATTERY MODULES, BATTERIES, ETC. FOR NEW FIRE ALARM SYSTEM. 7. CONTRACTOR SHALL PROVIDE FIRE ALARM STROBE CONTRACTOR SHALL PROVIDE FIRE ALARM STROBE SYNCHRONIZATION REQUIREMENT PER NFPA. ALL LINE-OF-SIGHT STROBE DEVICES SHALL BE SYNCHRONIZED. 8. CONTRACTOR SHALL COORDINATE FIRE ALARM RISER DIAGRAM CONTRACTOR SHALL COORDINATE FIRE ALARM RISER DIAGRAM WITH FIRE ALARM DEVICE LAYOUT ON PLAN. PROVIDE ADDITIONAL DEVICE AS REQUIRED TO MEET NEC AND NFPA REQUIREMENT.

AutoCAD SHX Text EXISTING VA FIRE ALARM SYSTEM IS BY NOTIFIER POC: CASEY HOUTZ GENERAL MANAGER PACIFIC SIGNALING SYSTEMS 5627 STONERIDGE DR. SUITE 321 PLEASANTON, CA 94588 OFFICE: 925-828-2400 MOBILE: 510-460-0526 PACIFIC SIGNALING HAVE INSTALLED THE EXISTING FIRE ALARM SYSTEM ON THE VA MARTINEZ CAMPUS. ALSO, THEY HAVE AN EXISTING SERVICE CONTRACT FOR THE FIRE ALARM SYSTEM. CONTRACTOR SHALL SUBCONTRACT THE DISCONNECT/RECONNECT, WIRING AND PROGRAMMING (ADDING/DELETING DEVICES) FOR THE EXISTING FIRE ALARM SYSTEM WITH PACIFIC SIGNALING.

AutoCAD SHX Text

PROVIDE NEW FIRE ALARM DEVICE TO MATCH EXISTING SYSTEM AND CONNECT TO (E) FIRE ALARM SYSTEM COMPLETE. SEE FIRE ALARM SYSTEM GENERAL NOTE AND RISER DIAGRAM AS INDICATED ON THIS SHEET FOR REQUIREMENTS.

2 3 4 5

N

P

Q

R

S

T

U

V

B2

B214M

/A 157 SF

B214B

EXAM

/A 274 SF

B214A

ENT

PROCEDURE

/A 107 SF

B214C

OFFICE

/A 155 SF

B214E

EXAM

/A 105 SF

B214D

OFFICE

/A 110 SF

B214F

CLEAN UTILITY

/ OMNI

/A 155 SF

B214G

EXAM

/A 155 SF

B214I

EXAM

/A 58 SF

B214H

TOILET

/A 44 SF

B214L

SOILED

UTILITY

/A 237 SF

B214J

TEAM ROOM

/A 207 SF

B214K

ENT EXAM

/A 387 SF

CORRIDOR

/A 387 SF

CORRIDOR

B2

K

B2

J

B2

L

B2

A

B214B

B214C

B214D

B214E

B214F

B214G

B214H

B214I

R.2

A5075

A5077

F2010B F3200

M5025

M5025

M1825

M5025R

M5025R

A5075

F3200

M5600A

M5500R

A5082

F2000

A5075

R7250

F0225

A5077

F0205

F0206A

F0740 F0206A F0205 F0205 F0206A F0740

F0206AF2000

M1800 M1801

A5145

M1801 M1802

F0280 F0280 F0280 F0280

M5025

A5082

F0465B

F3200

M5710

M5531 M6050R

A5082

A5077

M1801

M1802CT020

C04E0

C04E0

C06M0

C06M0

C04E0

CT020

C04E0

C04E0

A1015

A1015

F0280

F0280

M1801

F0410

F0410

F3200

F2000

A1017

E0990

M5710

M5530 M5730A

M5530 M5730A

A1015 M5520

M5535 M5705

M4200D A5082

M5562 A5107A

A5145

F3200

CD040

CD040

CD040

A1017

A1015

M1810R

F2540R

M5601

A5082

A5082

F3200

F2300

A5107A

A6046D A6046D A6046D

A5107A

F0340B

F0340B

F0340B

A5107AA5082

F0714

A5225

M1801 M1800

R6200A

F0714

M1825

A1015

A5075A

A5225

M1801

M6045R

F0340B

F0340B

F0340B

F0340B F0340B

M5520

M5700

F2000

M5574RM5025

A1017

M5570AR

A5108 A5107A

M5025R M6045R

F2000

M5500A

A5075

A5077

M0825A

M5575A M5575B

M5580

M5585 M5595 M5605 M5700

M5700A M5715

M6040 U1021

M5500A M5600A

A5225M1801 M1800

A1015

M5520

M5535

M5705

M5520M5700A5082

M5562

A5107AA5075A

F2000

A5075

M0825A

M5575B

M5585 M5595 M5605

M5700A

M5715

M6040U1021 M5601 M5580

F0340B

F0340B A5077

A5077

F3200

M5710

M5530 M5730A

A5145

M5600A

A5225M1801 M1800

A1015

M5520

M5535

M5705

M5520M5700 A5082

M5562

A5107A

F2000

A5075

M0825A M5575B

M5585 M5595 M5605

M5700A

M5715

M6040U1021 M5601 M5580

F0340B

A5077

F0340B

M5015

M4200D M4200D

F3200

M5710

M5530 M5730A

A5145

M5600A

A5225M1801 M1800

A1015

M5520

M5535

M5705 M5520M5700

M5562

A5107A A5075A

F2000

A5075

M0825A M5575B M5575B

M5585 M5595 M5605

M5700A

M5715

M6040 U1021M5601 M5580

F0340B

A5077

M4200D

A1015

M5510R

M5025R

A5145

M0515 A5210

A5075

A5077

CD040

CD040

CD040 CD040

CD040

CD040

CD040

A5075 A5075A

A5075A A5075

A5077

A5075A

M1825

F3200

A5075A

A5075A A5075A

M5575A M5575A

M5700A

F2300

M5551

A5075A

A5145

F2000

F3200F3050B

F0225

F0225 F0225

F0225F0225

F0225

F0225

F0795

F0795

A5225A A1015

F0750C M1801

A5225A M1801

A1015 A5225A F0750C M1801

A5225A M1801

F0280 F0280 F0280 F0280

A5225A A1015 A1015

M1801 A5225A A5225A A5225A

F0750CF0750C

M1801 M1801

M1801

F3050B

A5150

A5150 F3200

M1620

M1620

M1620

M1620 M1620

A5077

M1620

M1620

M1620 A5077

M1620

F0280A F0280A

F0280A

F0280A

F0280A F0280A

F0340B

F0280A

F0206

F0206

F0206

F0205

A6046D

A6046D

A6046D

A6046C A6046C A6046C

A6046B A6046B

F2010B

A5225

M1801 M1800

A1015 M5520

M5535 M5705

M4200DA5082

M5562

A5107A

A5075A A5075M0825A

M5575A M5575B

M5585 M5595 M5605 M5700

M5700A

M5715 M6040 U1021

CD040

M5600A

M5730A M5601 M5530

M5580

F2010B

F2010B

F2010B

F2010B

F2010B F2010B

F2010B

F2010B

A5145

K1552

K4665 K4665A

F2000

A5108

A5075A

F2026A

CS010A

CT020B

C04Q0A

C02D0A

U1005 U1006

E0257B

E0257C

E0257C

E0257C

CD040C CD040C

C04E0A C04E0A C04Q0A

CS010A

A5108

A5108 A5108

A5108

A5108

A5108

E0948

E0948

E0948

M1801

M3070

P3200

A5107A A5077

M9035

M9035

M9035

M9035

F0206

F0280

F0340

M7401

M4116

M4100 M4200

A5107A

F3050A

A5077 F2010A

E0257A

A5108

A5075

A5075A

A5145

M3072

M4116

M4255

M7415

M8810

M4100

A5107A F2010A

A5077

F0340

M3150A

A5077 F2010

A6046A

A6046A

M3070

F2300

F3050

F3050F3050

F3050

F3050

E0257 A5075

F3200

A5077 A5082

F2010A

A5108

A5107A

M4100

M4200

M7401M4116

F0340

F0206

F3050A A5145

A6046A M4915

F3050

A5145

F3200

F0280

F2000

A5145

M5601

A5075A

M8540

U1094

M4840

M8606

M4915

M5601

F0340

A5108

A5075A A5082

A5075

F3050A

M3070 M0750 M0755 M0765

F2300

A1015 A5225 M1800 M1801

F0713

F2010 A5090 A5202

A5109

P9051

A1067 P3200

A5075

A5082A5145

A5075 A5082

A5077 F3200

A1015 A5225

F0713

M1800 M1801

F0280

A1015

F0750B

A1015 A5225

F0713

M1800 M1801

F0280 A1015 A5225

F0713

M1800 M1801

F0280

F2000

F0420A

F0280

M1801 M1800 A5225 A1015

F0713

F3050B

A5145

F3050B

A5108

F3050

A6046A

A6046A

A6046A

A6046A

A6046A

A6046A

A6046AA6046A

A6046A

A5225

M1800 M1801

M5710

M5015

F3200

A5145

A1017

F0465A

M1801 M1802

M1801 M1802

A1015

E0075A

F0205

F0465C F0206

A5225F0280

F2300

A5108 A5075A

A1015

M1801

F0713

F2010A F0340

A5077M4116

A6046A

F3050A

A5107A M4200 M4100

M7401

A5145

F2300

F0206

M1800 M1801

M1800

F0280

F0340

A5108

F2010A M4116

M7401

M4100 M4200

A5107A

F3050A

A5077

A1015 A5225

F0713

A5075A

A6046A

F0280

A6046A

M1800 A1015 A5225 M1801

F0713

M4116

M7401

M4100 M4200

A5107A

F3050A

F0340

F0206 A5108 A5075A

F2010A A5077

F2300

A5145

A5145

F0205

F0280 E0075A

F0465C

F3200

A1015 F2000

F3050

M4200

F0465A E0948A

E0948A

E0948A

E0948A

M8810

F0465

F0535

F0465A

M2055

M2055 M2055 M2055A

F2000

A1017

M3072

F0225

F0225

F0225

F0225

A5075 E0257A

A5082

A5082

A5082

A5075

A5075

A5082

M1825

A5075A

A5082

A6046A

A6046A

A6046A

A6046A

A5077

A5077

A5077

A5180

A5180

A5180

A5180

A5180

A5180

A5145

A6046A

M4840

E0948A

M8540

M8606

M0750 M0755 M0765

E0257A

E0257A

F2000

F3200

F3200

F3200

F3200

F3200

E0257D

F3200

F0206

PHASE 1

CONSTRUCTION

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

ARCHITECT OF RECORD

BI

M

M ar tin ez B

/6

-1

8-

9_ A.

rv t

2/ 9/

:0

0:

P M

CONCOURSE FEDERAL GROUP

213 SOUTH ROYAL STREET

ALEXANDRIA, VA 22314

GENE KLOW

REMODEL SPECIALTY

CARE - BUILDING 19

VA MARTINEZ

612-18-329

03/26/2021

100% - BID SET

Revisions: Date:

CONSULTING ENGINEERS

F.W. A NC.SSOCIATES,I

SJ/MF FWA TEAM

ES4-2

PHASE 1 SECOND FLOOR -

FIRE ALARM

SHEET NOTES

PHASE 1 SECOND FLOOR - FIRE ALARM

GENERAL NOTEGENERAL NOTE

N

KEY PLAN

Floor 2

2 2 4 6 8 10 1/4" = 1'-0"

FEETSCALE

AutoCAD SHX Text

AutoCAD SHX Text

(TYP)

AutoCAD SHX Text

520 3RD STREET, SUITE 206, OAKLAND, CA 94607

AutoCAD SHX Text

PHONE: (510) 763-7475

AutoCAD SHX Text

FAX: (510) 763-7033

AutoCAD SHX Text No.10436

AutoCAD SHX Text Exp.9-30-2022

AutoCAD SHX Text

AutoCAD SHX Text

SCALE: 1/4"=1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

1. REFER TO FIRE ALARM SYSTEM GENERAL REFER TO FIRE ALARM SYSTEM GENERAL NOTES AND RISER DIAGRAM ON SHEET ES4-1 FOR FIRE ALARM REQUIREMENTS.

PROVIDE NEW FIRE ALARM DEVICE TO MATCH EXISTING SYSTEM AND CONNECT TO (E) FIRE ALARM SYSTEM COMPLETE. SEE FIRE ALARM SYSTEM GENERAL NOTE AND RISER DIAGRAM AS INDICATED ON DRAWING SHEET ES4-1 FOR REQUIREMENTS.

A5075

A5077

F2010B F3200

M5025

M5025

M1825

M5025R

M5025R

A5075

F3200

M5600A

M5500R

A5082

F2000

A5075

R7250

F0225

A5077

F0205

F0206A

F0740 F0206A F0205 F0205 F0206A F0740

F0206AF2000

M1800 M1801

A5145

M1801 M1802

F0280 F0280 F0280 F0280

M5025

A5082

F0465B

F3200

M5710

M5531 M6050R

OCT

A5082

A5077 check-in

M1801

M1802CT020

C04E0

C04E0

C06M0

C06M0

C04E0

CT020

C04E0

C04E0

A6105 A1015

A1015

F0280

F0280

M1801

F0410

F0410

F3200

F2000

A1017

E0990

M5710

M5530 M5730A

M5530 M5730A

M5599

A1015 M5520

M5535 M5705

M4200D A5082

M5562 A5107A

A5145

F3200

CD040

CD040

CD040

A1017

A1015

M1810R

F2540R

M5601

A5082

A5082

F3200

F2300

A5107A

A6046D A6046D A6046D

A5107A

F0340B

F0340B

F0340B

A5107AA5082

F0714

A5225

M1801 M1800

R6200A

F0714

M1825

A1015

A5075A

A5225

A6311

M1801

M6045R

F0340B

F0340B

F0340B

F0340B F0340B

M5520

M5700

F2000

M5574RM5025

A1017

M5570AR

A5108 A5107A

M5025R M6045R

F2000

M5500A

A5075

A5077

M0825A

M5575A M5575B

M5580

M5585 M5595 M5605 M5700

M5700A M5715

M6040 U1021

M5500A M5600A M5599

A5225M1801 M1800

A1015

M5520

M5535

M5705

M5520M5700A5082

M5562

A5107AA5075A

F2000

A5075

M0825A

M5575B

M5585 M5595 M5605

M5700A

M5715

M6040U1021 M5601 M5580

F0340B

F0340B A5077

A5077

F3200

M5710

M5530 M5730A

A5145

M5600A M5599

A5225M1801 M1800

A1015

M5520

M5535

M5705

M5520M5700 A5082

M5562

A5107A

F2000

A5075

M0825A M5575B

M5585 M5595 M5605

M5700A

M5715

M6040U1021 M5601 M5580

F0340B

A5077

F0340B

M5015

M4200D M4200D

F3200

M5710

M5530 M5730A

A5145

M5600A M5599

A5225M1801 M1800

A1015

M5520

M5535

M5705 M5520M5700

M5562

A5107A A5075A

F2000

A5075

M0825A M5575B M5575B

M5585 M5595 M5605

M5700A

M5715

M6040 U1021M5601 M5580

F0340B

A5077

M4200D

A1015

M5510R

M5025R

A5145

M0515 A5210

A5075

A5077

CD040

CD040

CD040 CD040

CD040

CD040

CD040

A5075 A5075A

A5075A A5075

A5077

A5075A

M1825

F3200

A5075A

A5075A A5075A

M5575A M5575A

M5700A

F2300

M5551

A5075A

A5145

F2000

F3200F3050B

F0225

F0225 F0225

F0225F0225

F0225

F0225

F0795

F0795

A5225A A1015

F0750C M1801

A5225A M1801

A1015 A5225A F0750C M1801

A5225A M1801

F0280 F0280 F0280 F0280

A5225A A1015 A1015

M1801 A5225A A5225A A5225A

F0750CF0750C

M1801 M1801

M1801

F3050B

A5150

A5150 F3200

M1620

M1620

M1620

M1620 M1620

A5077

M1620

M1620

M1620 A5077

M1620

F0280A F0280A

F0280A

F0280A

F0280A F0280A

F0340B

F0280A

F0206

F0206

F0206

F0205

A6046D

A6046D

A6046D

A6046C A6046C A6046C

A6046B A6046B

F2010B

A5225

M1801 M1800

A1015 M5520

M5535 M5705

M4200DA5082

M5562

A5107A

A5075A A5075M0825A

M5575A M5575B

M5585 M5595 M5605 M5700

M5700A

M5715 M6040 U1021

CD040

M5600A

M5730A M5601 M5530

M5580

M5599

F2010B A1132

F2010B

F2010B

F2010B

F2010B F2010B

F2010B

F2010B

A1132

A5145

A1132

A1132

A1132

A1132 A1132

CD040B

A1132

A1132

K1552

K4665 K4665A

F2000

A6311

A6311

A6311

A6311

A1132

A6311 A6311 A6311

A5108

A5075A

F2026A

CS010A

CT020B

C04Q0A

C02D0A

U1005 U1006

E0257B

E0257C

E0257C

E0257C

CD040C CD040C

C04E0A C04E0A C04Q0A

CS010A

A5108

A5108 A5108

A5108

A5108

A5108

PHASE 1 CONSTRUCTION

PHASE 2 CONSTRUCTION

E0948

E0948

E0948

M1801

M3070

P3200

A5107A A5077

M9035

M9035

M9035

M9035

F0206

F0280

F0340

M7401

M4116

M4100 M4200

A5107A

F3050A

A5077 F2010A

E0257A

A5108

A5075

A5075A

A5145

M3072

M4116

M4255

M7415

M8810

M4100

A5107A F2010A

A5077

F0340

A1132

M3150A

A5077 F2010

A6046A

A6046A

M3070

F2300

F3050

F3050F3050

F3050

F3050

E0257 A5075

F3200

A5077 A5082

F2010A

A5108

A5107A

M4100

M4200

M7401M4116

F0340

F0206

F3050A A5145

A6046A M4915

F3050

A5145

F3200

F0280

F2000

A5145

M5601

A5075A

M8540

U1094

M4840

M8606

M4915

M5601

F0340

A5108

A5075A A5082

A5075

F3050A

M3070 M0750 M0755 M0765

F2300

A1015 A5225 M1800 M1801

F0713

F2010 A5090 A5202

A5109

P9051

A1067 P3200

A5075

A5082A5145

A5075 A5082

A5077 F3200

A1015 A5225

F0713

M1800 M1801

F0280

A1015

F0750B

A1015 A5225

F0713

M1800 M1801

F0280 A1015 A5225

F0713

M1800 M1801

F0280

F2000

F0420A

F0280

M1801 M1800 A5225 A1015

F0713

F3050B

A5145

FEC

FEC

F3050B

A5108

F3050

A6046A

A6046A

A6046A

A6046A

A6046A

A6046A

A6046AA6046A

A6046A

U1041 M5015

A5225

M1800 M1801

U1041 M5015

M5710

U1041

U1041 M5015

CT020A

F3200

A5145

A1017

F0465A

M1801 M1802

M1801 M1802

A1015

E0075A

F0205

F0465C F0206

A5225F0280

F2300

A5108 A5075A

A1015

M1801

F0713

F2010A F0340

A5077M4116

A6046A

F3050A

A5107A M4200 M4100

M7401

A5145

F2300

F0206

M1800 M1801

M1800

F0280

F0340

A5108

F2010A M4116

M7401

M4100 M4200

A5107A

F3050A

A5077

A1015 A5225

F0713

A5075A

A6046A

F0280

A6046A

M1800 A1015 A5225 M1801

F0713

M4116

M7401

M4100 M4200

A5107A

F3050A

F0340

F0206 A5108 A5075A

F2010A A5077

F2300

A5145

A5145

F0205

F0280 E0075A

F0465C

F3200

A1015 F2000

F3050

FEC

A1132

M4200

F0465A E0948A

E0948A

E0948A

E0948A

M8810

F0465

F0535

F0465A

M2055

M2055 M2055 M2055A

F2000

A1017

M3072

F0225

F0225

F0225

F0225

A5075 E0257A

A5082

A5082

A5082

A5075

A1132

A5075

A1132

A5082

A6311

M1825

A6311

A5075A

A5082

A6046A

A6046A

A6046A

A6046A

A5077

A5077

A5077

A5180

A5180

A5180

A5180

A5180

A5180

A5145

A6046A

M4840

E0948A

M8540

M8606

M0750 M0755 M0765

E0257A

E0257A

F2000

F3200

F3200

F3200

F3200

F3200

E0257D

F3200

F0206

2 3 4 5

N

P

Q

R

S

T

U

V

/A 151 SF

B202

PRE-SCREENING/

EXAM 2

EYOT2

/A 165 SF

B203

PRE-SCREENING/

EXAM 3

EYOT2

/A 120 SF

B204

WAITING

WTG03

/A 159 SF

B224

(E) EXAM 3

/A 162 SF

B225

(E) EXAM 4

/A 167 SF

B226

PROCEDURE/

EXAM

/A 70 SF

B392

(E) HUDDLE

/A 125 SF

B227

RN/ PA OFFICE

/A 204 SF

B213

CATARACT

SURGERY

TESTING

/A 111 SF

B212

VISUAL FIELD

EYVF1

/A 132 SF

B209

EXAM/

TREATMENT 9

EYOT2 /A 132 SF

B210

EXAM/

TREATMENT 8

EYOT2

/A 141 SF

B223

(E) OFFICE /

EXAM

/A 113 SF

B205

(E) EXAM/

TREATMENT 5

/A 210 SF

B206

MD TECH

WKSTN

WRTM1

/A 120 SF

B207

EXAM/

TREATMENT 7

EYOT2/A 133 SF

B208

BREAK ROOM

SL001

/A 281 SF

CORRIDOR

/A 417 SF

B349

WAITING

/A 139 SF

B216A

RECEPTION -

EYE CLINIC

RCP1

B3

A

B2

B2

B2

B2

B2

B212

B213

B201

B202

B200

B2

/A 19 SF

B200

SOILED

/A 19 SF

B200

SOILED

/A 92 SF

B201

PRE-SCREENING/

EXAM 1

EYVS1

B214M

B2

B203

/A 190 SF

B211

OCT

IMAGING/FUNDUS

PHOTO

EYVS1

/A 334 SF

CORRIDOR

/A 274 SF

B214A

PROCEDURE

TRPR1

/A 157 SF

B214B

EXAM

EXPA1

/A 107 SF

B214C

OFFICE

OFA07

/A 105 SF

B214D

OFFICE

OFA07

/A 107 SF

B214F

CLEAN UTILITY

/ OMNI

/A 58 SF

B214H

TOILET

TLTU1 /A 44 SF

B214L

SOILED

UTILITY

USCL1

/A 155 SF

B214E

EXAM

EXPA1

/A 155 SF

B214G

EXAM

EXPA1

/A 155 SF

B214I

EXAM

EXPA1

/A 237 SF

B214J

TEAM ROOM

WRTM1

/A 387 SF

CORRIDOR

/A 387 SF

CORRIDOR

/A 387 SF

CORRIDOR

/A 207 SF

B214K

ENT EXAM

EXPA1

R.2

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

ARCHITECT OF RECORD

BI

M

M ar tin ez B

/6

-1

8-

9_ A.

rv t

2/ 9/

:0

0:

P M

CONCOURSE FEDERAL GROUP

213 SOUTH ROYAL STREET

ALEXANDRIA, VA 22314

GENE KLOW

REMODEL SPECIALTY

CARE - BUILDING 19

VA MARTINEZ

612-18-329

03/26/2021

100% - BID SET

Revisions: Date:

CONSULTING ENGINEERS

F.W. A NC.SSOCIATES,I

SJ/MF FWA TEAM

ES4-3

PHASE 2 SECOND FLOOR -

FIRE ALARM

SHEET NOTES

PHASE 2 SECOND FLOOR - FIRE ALARM

GENERAL NOTEGENERAL NOTE

N

KEY PLAN

Floor 2

2 2 4 6 8 10 1/4" = 1'-0"

FEETSCALE

AutoCAD SHX Text

(TYP)

AutoCAD SHX Text

AutoCAD SHX Text

520 3RD STREET, SUITE 206, OAKLAND, CA 94607

AutoCAD SHX Text

PHONE: (510) 763-7475

AutoCAD SHX Text

FAX: (510) 763-7033

AutoCAD SHX Text No.10436

AutoCAD SHX Text Exp.9-30-2022

AutoCAD SHX Text

AutoCAD SHX Text

SCALE: 1/4"=1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

1. REFER TO FIRE ALARM SYSTEM GENERAL REFER TO FIRE ALARM SYSTEM GENERAL NOTES ON SHEET ES4-1 FOR ADDITIONAL REQUIREMENTS.

PROVIDE NEW FIRE ALARM DEVICE TO MATCH EXISTING SYSTEM AND CONNECT TO (E) FIRE ALARM SYSTEM COMPLETE. SEE FIRE ALARM SYSTEM GENERAL NOTE AND RISER DIAGRAM AS INDICATED ON DRAWING SHEET ES4-1 FOR REQUIREMENTS.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

ARCHITECT OF RECORD

BI

M

M ar tin ez B

/6

-1

8-

9_ A.

rv t

2/ 9/

:0

0:

P M

CONCOURSE FEDERAL GROUP

213 SOUTH ROYAL STREET

ALEXANDRIA, VA 22314

GENE KLOW

REMODEL SPECIALTY

CARE - BUILDING 19

VA MARTINEZ

612-18-329

03/26/2021

100% - BID SET

Revisions: Date:

CONSULTING ENGINEERS

F.W. A NC.SSOCIATES,I

SJ/MF FWA TEAM

ES5-1

SINGLE LINE DIAGRAM FOR

REFERENCE

SINGLE LINE DIAGRAM - FOR REFERENCE ONLY

AutoCAD SHX Text

%%U(E) "HADP"

AutoCAD SHX Text

(E) 1600A, 480V, 3%%C, 4W

AutoCAD SHX Text

TX1

AutoCAD SHX Text

30KVA

AutoCAD SHX Text

CHILLER #2

AutoCAD SHX Text

280 7KVA

AutoCAD SHX Text G

AutoCAD SHX Text

(E) GENERATOR

AutoCAD SHX Text

750KW, 480V

AutoCAD SHX Text

STABLUTO E/S

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

(E) SUBSTRUCTURE #2

AutoCAD SHX Text

(E) 4-4"C STUBBED TO MANHOLE

AutoCAD SHX Text

(E) REMOTE MAIN

AutoCAD SHX Text

DISCONNECT

AutoCAD SHX Text

PUSH BUTTON

AutoCAD SHX Text

(1256.3 KVA)

AutoCAD SHX Text 100A

AutoCAD SHX Text 3P

AutoCAD SHX Text 350A

AutoCAD SHX Text 3P

AutoCAD SHX Text 125A

AutoCAD SHX Text 3P

AutoCAD SHX Text 800A

AutoCAD SHX Text 3P

AutoCAD SHX Text

GFI

AutoCAD SHX Text 225A

AutoCAD SHX Text 3P

AutoCAD SHX Text 125A

AutoCAD SHX Text 3P

AutoCAD SHX Text 400A

AutoCAD SHX Text 3P

AutoCAD SHX Text 225A

AutoCAD SHX Text 3P

AutoCAD SHX Text

(E) SUBSTRUCTURE #1

AutoCAD SHX Text

(E) REMOTE MAIN

AutoCAD SHX Text

DISCONNECT

AutoCAD SHX Text

PUSH BUTTON

AutoCAD SHX Text

(1215.0KVA)

AutoCAD SHX Text 400A

AutoCAD SHX Text 3P

AutoCAD SHX Text 200A

AutoCAD SHX Text 3P

AutoCAD SHX Text 200A

AutoCAD SHX Text 3P

AutoCAD SHX Text 150A

AutoCAD SHX Text 3P

AutoCAD SHX Text 600A

AutoCAD SHX Text 3P

AutoCAD SHX Text 350A

AutoCAD SHX Text 3P

AutoCAD SHX Text 300A

AutoCAD SHX Text 3P

AutoCAD SHX Text

(E) 4-3 1/2"C, 4#600 MCM

AutoCAD SHX Text

& 1#4/0 GND EA

AutoCAD SHX Text

(E) 4-3 1/2"C, 4#600 MCM

AutoCAD SHX Text

& 1#4/0 GND EA

AutoCAD SHX Text

(E) 3-3 1/2"C, 4#600 MCM &

AutoCAD SHX Text

1#3/0 GND EA

AutoCAD SHX Text

GENERATOR

AutoCAD SHX Text

CONTROL PANEL

AutoCAD SHX Text

GEN

AutoCAD SHX Text

ANN

AutoCAD SHX Text 400A

AutoCAD SHX Text 3P

AutoCAD SHX Text

MTS-B

AutoCAD SHX Text

CHILLER #1

AutoCAD SHX Text

280.7KVA

AutoCAD SHX Text

CHILLER #1

AutoCAD SHX Text

205KW

AutoCAD SHX Text

(E) 200/3/480/125A

AutoCAD SHX Text

ELEVATOR

AutoCAD SHX Text 600A

AutoCAD SHX Text 3P

AutoCAD SHX Text 800A

AutoCAD SHX Text 3P

AutoCAD SHX Text

(E) 800A, 120/208V, 3%%C, 4W

AutoCAD SHX Text

(E) 600A, 120/208V, 3%%C, 4W

AutoCAD SHX Text

"TXA"

AutoCAD SHX Text 480V-120/208V

AutoCAD SHX Text

225KVA

AutoCAD SHX Text

(163.6KVA)

AutoCAD SHX Text

(E) "LADP"

AutoCAD SHX Text

(E) "LBDP"

AutoCAD SHX Text

(200.5KVA)

AutoCAD SHX Text

(E) "TXB"

AutoCAD SHX Text 480V-120/208V

AutoCAD SHX Text

300KVA

AutoCAD SHX Text

(E) 600A, 480/277V, 3%%C, 4W

AutoCAD SHX Text

(E) "MCCA"

AutoCAD SHX Text

(304.5KVA)

AutoCAD SHX Text

ROOM

AutoCAD SHX Text L5/1147

AutoCAD SHX Text

X-RAY

AutoCAD SHX Text

66.4KVA

AutoCAD SHX Text

ROOM

AutoCAD SHX Text L5/1147

AutoCAD SHX Text

X-RAY

AutoCAD SHX Text

66.4KVA

AutoCAD SHX Text

WP

AutoCAD SHX Text

132.9KVA

AutoCAD SHX Text

MR1

AutoCAD SHX Text 200A

AutoCAD SHX Text

3PNF

AutoCAD SHX Text 3P

AutoCAD SHX Text 450A

AutoCAD SHX Text 3P

AutoCAD SHX Text 225A

AutoCAD SHX Text 150A

AutoCAD SHX Text 3P

AutoCAD SHX Text

ROOM

AutoCAD SHX Text L15/1119

AutoCAD SHX Text

CHEST X-RAY

AutoCAD SHX Text

66.4KVA

AutoCAD SHX Text

ST

AutoCAD SHX Text 125A/3P

AutoCAD SHX Text

ATS-A

AutoCAD SHX Text 2nd

AutoCAD SHX Text

FLOOR

AutoCAD SHX Text 1st

AutoCAD SHX Text

FLOOR

AutoCAD SHX Text

HAA2

AutoCAD SHX Text

HAA1

AutoCAD SHX Text 800A

AutoCAD SHX Text 4P

AutoCAD SHX Text

POWER

AutoCAD SHX Text

CAB

AutoCAD SHX Text

FBO

AutoCAD SHX Text H1

AutoCAD SHX Text

18KVA

AutoCAD SHX Text

(E) "TXC"

AutoCAD SHX Text 480V-120/208V

AutoCAD SHX Text

300KVA

AutoCAD SHX Text 3P

AutoCAD SHX Text 70A

AutoCAD SHX Text 3P

AutoCAD SHX Text 50A

AutoCAD SHX Text 3P

AutoCAD SHX Text 30A

AutoCAD SHX Text

MCP15

AutoCAD SHX Text

AutoCAD SHX Text

MCP30

AutoCAD SHX Text

AutoCAD SHX Text

(E) "EMCC"

AutoCAD SHX Text

(E) 800A, 120/208V, 3%%C, 4W

AutoCAD SHX Text

(E) 1000A, 120/208V, 3%%C, 4W

AutoCAD SHX Text 1000A

AutoCAD SHX Text 3P

AutoCAD SHX Text

"ETXA"

AutoCAD SHX Text 480V-120/208V

AutoCAD SHX Text

300KVA

AutoCAD SHX Text

5HP

AutoCAD SHX Text P-9

AutoCAD SHX Text

(PRIMARY)

AutoCAD SHX Text P-9

AutoCAD SHX Text

(SECONDARY)

AutoCAD SHX Text

15HP

AutoCAD SHX Text

AHU-7

AutoCAD SHX Text

60A/3P/NF

AutoCAD SHX Text 800A

AutoCAD SHX Text 3P

AutoCAD SHX Text

(E) "LCDP"

AutoCAD SHX Text

(E) "ELDP"

AutoCAD SHX Text

(225.9KVA)

AutoCAD SHX Text 150A/3P

AutoCAD SHX Text 150A/3P

AutoCAD SHX Text

(E) 6-4"C.O. STUBBED

AutoCAD SHX Text

TO MANHOLE

AutoCAD SHX Text

(E) 3/4"C, 3#12

AutoCAD SHX Text

FUTURE NURSING HOME

AutoCAD SHX Text

GFI

AutoCAD SHX Text 1600A/3P

AutoCAD SHX Text

1500AT

AutoCAD SHX Text

(E) 4000A, 480/277V, 3%%C, 4W 100KAIC

AutoCAD SHX Text

%%U(E) MAIN SWITCHBOARD "MSB" NEMA 3R ENCLOSURE

AutoCAD SHX Text

(E) ELA1-20

AutoCAD SHX Text

FOR STRIP

AutoCAD SHX Text

HEADERS &

AutoCAD SHX Text

SHUNT TRIP

AutoCAD SHX Text

%%U(E) "HBDP"

AutoCAD SHX Text

(E) 1600A, 480V, 3%%C, 4W

AutoCAD SHX Text

GFI

AutoCAD SHX Text

GFI

AutoCAD SHX Text M

AutoCAD SHX Text 4000A

AutoCAD SHX Text 3P

AutoCAD SHX Text A

AutoCAD SHX Text V

AutoCAD SHX Text 1600A/3P

AutoCAD SHX Text

1500AT

AutoCAD SHX Text

(E) 3/4"C, 3#12

AutoCAD SHX Text

(E) 4000A, 480/277V 3%%C, 4W

AutoCAD SHX Text

WEATHER PROOF BUS DUCT

AutoCAD SHX Text

(E) PG&E PAD MOUNTED

AutoCAD SHX Text

TRANSFORMER

AutoCAD SHX Text

(E) 1200A, 480/277V, 3%%C, 4W

AutoCAD SHX Text 800A

AutoCAD SHX Text 3P

AutoCAD SHX Text 125A

AutoCAD SHX Text 3P

AutoCAD SHX Text 400A

AutoCAD SHX Text 3P

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text

%%U(E) "EMDP"

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text 800A

AutoCAD SHX Text 3P

AutoCAD SHX Text

(E) 800A, 480/277V, 3%%C, 4W

AutoCAD SHX Text (E)

AutoCAD SHX Text

AUTOMATIC

AutoCAD SHX Text

(E) NON-

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text

(E) "EHCP"

AutoCAD SHX Text (E)

AutoCAD SHX Text

(E) PANEL "L1"

AutoCAD SHX Text 3P

AutoCAD SHX Text 150A

AutoCAD SHX Text (E)

AutoCAD SHX Text

(E) "LCE2"

AutoCAD SHX Text 3P

AutoCAD SHX Text 225A

AutoCAD SHX Text (E)

AutoCAD SHX Text

(E) "LCC2"

AutoCAD SHX Text

(E) "LCD2"

AutoCAD SHX Text 3P

AutoCAD SHX Text 225A

AutoCAD SHX Text (E)

AutoCAD SHX Text

(E) "LCA2"

AutoCAD SHX Text

(E) "LCB2"

AutoCAD SHX Text 3P

AutoCAD SHX Text 225A

AutoCAD SHX Text (E)

AutoCAD SHX Text

(E) "LBC2"

AutoCAD SHX Text

(E) "LBD2"

AutoCAD SHX Text 3P

AutoCAD SHX Text 300A

AutoCAD SHX Text (E)

AutoCAD SHX Text

(E) "LBA2"

AutoCAD SHX Text

(E) "LBB2"

AutoCAD SHX Text 3P

AutoCAD SHX Text 225A

AutoCAD SHX Text (E)

AutoCAD SHX Text

(E) "LAA2"

AutoCAD SHX Text

(E) "LAB2"

AutoCAD SHX Text 3P

AutoCAD SHX Text 150A

AutoCAD SHX Text (E)

AutoCAD SHX Text

(E) "ELC1"

AutoCAD SHX Text

(E) "ELC2"

AutoCAD SHX Text 3P

AutoCAD SHX Text 150A

AutoCAD SHX Text (E)

AutoCAD SHX Text

(E) "ELB1"

AutoCAD SHX Text

(E) "ELB2"

AutoCAD SHX Text 3P

AutoCAD SHX Text 225A

AutoCAD SHX Text (E)

AutoCAD SHX Text

(E) "ELA1"

AutoCAD SHX Text

(E) "ELA2"

AutoCAD SHX Text 3P

AutoCAD SHX Text 150A

AutoCAD SHX Text (E)

AutoCAD SHX Text

(E) PANEL "ELA2OR"

AutoCAD SHX Text 3P

AutoCAD SHX Text 15A

AutoCAD SHX Text (E)

AutoCAD SHX Text M

AutoCAD SHX Text 30A

AutoCAD SHX Text 3P

AutoCAD SHX Text (E)

AutoCAD SHX Text

(E) DUMBWAITER #2 3.98 KVA 3HP

AutoCAD SHX Text 3P

AutoCAD SHX Text 225A

AutoCAD SHX Text (E)

AutoCAD SHX Text

(E) "LBA1"

AutoCAD SHX Text

(E) "LBB1"

AutoCAD SHX Text

520 3RD STREET, SUITE 206, OAKLAND, CA 94607

AutoCAD SHX Text

PHONE: (510) 763-7475

AutoCAD SHX Text

FAX: (510) 763-7033

AutoCAD SHX Text No.10436

AutoCAD SHX Text Exp.9-30-2022

AutoCAD SHX Text

SCALE: N.T.S

AutoCAD SHX Text

NOTES:

INDICATES EXISTING CONDITION TO REMAIN

SHEET NOTES

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

ARCHITECT OF RECORD

BI

M

M ar tin ez B

/6

-1

8-

9_ A.

rv t

2/ 9/

:0

0:

P M

CONCOURSE FEDERAL GROUP

213 SOUTH ROYAL STREET

ALEXANDRIA, VA 22314

GENE KLOW

REMODEL SPECIALTY

CARE - BUILDING 19

VA MARTINEZ

612-18-329

03/26/2021

100% - BID SET

Revisions: Date:

CONSULTING ENGINEERS

F.W. A NC.SSOCIATES,I

SJ/MF FWA TEAM

ES6-1

PANEL SCHEDULE

AutoCAD SHX Text

HAA1

AutoCAD SHX Text

LBA1

AutoCAD SHX Text

HAA2

AutoCAD SHX Text

LBA2

AutoCAD SHX Text

EHA1

AutoCAD SHX Text

LBB1

AutoCAD SHX Text

EHA2

AutoCAD SHX Text

LCA2

AutoCAD SHX Text

ELB1

AutoCAD SHX Text

LCC2

AutoCAD SHX Text

ELC2

AutoCAD SHX Text

LCA1

AutoCAD SHX Text

AutoCAD SHX Text PROVIDE CIRCUIT BREAKER TO MATCH EXISTING PROVIDE UPDATED TYPE-WRITTEN PANEL SCHEDULE DIRECTORIES. CONTRACTOR SHALL FIELD VERIFY CIRCUIT REMOVAL WITHIN THE DEMOLITION SPACE AND UPDATE SCHEDULE DIRECTORY.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

520 3RD STREET, SUITE 206, OAKLAND, CA 94607

AutoCAD SHX Text

PHONE: (510) 763-7475

AutoCAD SHX Text

FAX: (510) 763-7033

AutoCAD SHX Text No.10436

Exp.9-30-2022

RECESSED DOWN LIGHT FIXTURE DETAIL

LIGHTING FIXTURE GROUNDING DETAIL

LIGHTING FIXTURE MOUNTING DETAIL

RECESSED FIXTURE IN T-BAR CEILING DETAIL

TYPICAL WALL OCCUPANCY SENSOR

TYPICAL DIMMING CONTROL

TYPICAL 50% OFF PRESET LIGHT LEVEL DIMMING

VIA OCCUPANCY SENSOR CONTROL FOR CORRIDOR

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

ARCHITECT OF RECORD

BI

M

M ar tin ez B

/6

-1

8-

9_ A.

rv t

2/ 9/

:0

0:

P M

CONCOURSE FEDERAL GROUP

213 SOUTH ROYAL STREET

ALEXANDRIA, VA 22314

GENE KLOW

REMODEL SPECIALTY

CARE - BUILDING 19

VA MARTINEZ

612-18-329

03/26/2021

100% - BID SET

Revisions: Date:

CONSULTING ENGINEERS

F.W. A NC.SSOCIATES,I

SJ/MF FWA TEAM

ES7-1

DETAILS AND DIAGRAMS

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

%%USCHEME "B"

AutoCAD SHX Text

%%USCHEME "A"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SPLICE CIA. &

AutoCAD SHX Text

GROUND WIRES

AutoCAD SHX Text

QUICK-CONNECT

AutoCAD SHX Text

ACCESS-HOLE.

AutoCAD SHX Text

GROUND WIRE AS

AutoCAD SHX Text

IN FIXTURE WIREWAY

AutoCAD SHX Text

PIGTAIL

AutoCAD SHX Text

TO FLEXIBLE

AutoCAD SHX Text

CONDUIT SYSTEM

AutoCAD SHX Text

PART OF FIXTURE

AutoCAD SHX Text

RING TONGUE TERMINAL

AutoCAD SHX Text

LED DRIVER OR

AutoCAD SHX Text

DRIVER/BALLAST MOUNTING

AutoCAD SHX Text

NON-TURNING GROUND STUD

AutoCAD SHX Text

FIXTURE HOUSING COMMON TO

AutoCAD SHX Text

LOCKNUT

AutoCAD SHX Text

STAR WASHER & NUT

AutoCAD SHX Text

ALL WORK SHOWN ON THIS DETAIL IS FACTORY INSTALLED.

AutoCAD SHX Text

ANCHOR TO BUILDING

AutoCAD SHX Text

STRUCTURAL STEEL

AutoCAD SHX Text

ATTACH TO FIXTURE

AutoCAD SHX Text

FRAME. THREE TURNS

AutoCAD SHX Text

FIXTURE FRAME AND

AutoCAD SHX Text

JUNCTION BOX

AutoCAD SHX Text

CEILING

AutoCAD SHX Text

IN 1" - TYPICAL

AutoCAD SHX Text

16 GA. CHANNEL THRU

AutoCAD SHX Text

FIXTURE FRAME.

AutoCAD SHX Text

EXTEND BEYOND MAIN

AutoCAD SHX Text

RUNNERS AND ATTACH

AutoCAD SHX Text

TO MAIN RUNNERS

AutoCAD SHX Text

WITH #18 GA. WIRES

AutoCAD SHX Text

MAIN RUNNERS

AutoCAD SHX Text

4'-0" 0.C. %%UTYPICAL

AutoCAD SHX Text

135%%D(TYP)

AutoCAD SHX Text 135%%d

AutoCAD SHX Text

LIGHTING

AutoCAD SHX Text

FIXTURE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 135%%d(TYP)

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

%%UPLAN VIEW

AutoCAD SHX Text

FIXTURE SHALL BE SECURED

AutoCAD SHX Text

AT FOUR CORNERS

AutoCAD SHX Text

SECURED TO STRUCTURE ABOVE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

STRAPS

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

135%%D(TYP)

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SUPPORT

AutoCAD SHX Text

MECHANICAL SUPPLIED

AutoCAD SHX Text

UNISTRUT FOR DUCT

AutoCAD SHX Text

WRAP WIRE AROUND

AutoCAD SHX Text

UNISTRUT & SECURE

AutoCAD SHX Text

#12 GALVANIZED CARBON

AutoCAD SHX Text

STEEL WIRE (TYP)

AutoCAD SHX Text

SECURE FIXTURE WITH

AutoCAD SHX Text

WIRE AT FOUR CORNERS

AutoCAD SHX Text

MECHANICAL DUCT

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SECURED TO STRUCTURE ABOVE

AutoCAD SHX Text

#12 WIRE (TYP)

AutoCAD SHX Text

#12 WIRE (TYP)

AutoCAD SHX Text

LIGHTING FIXTURE

AutoCAD SHX Text

CEILING TILE

AutoCAD SHX Text

(TYPICAL)

AutoCAD SHX Text

MECHANICAL FURNISHED

AutoCAD SHX Text

#12 WIRE (TYP)

AutoCAD SHX Text

ELECTRICAL FURNISHED

AutoCAD SHX Text

UNISTRUT INSTALLED

AutoCAD SHX Text

BELOW MECHANICAL DUCT

AutoCAD SHX Text

CEILING TILE (TYP)

AutoCAD SHX Text

LIGHTING FIXTURE

AutoCAD SHX Text

FLUORESCENT BALLAST

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

SUPPORT TIE WIRES TO BUILDING STRUCTURAL STEEL,

AutoCAD SHX Text

USE GALVANIZED, #12 GAUGE (MINIMUM), SOFT IRON

AutoCAD SHX Text

WIRE. TIE AT FOUR CORNERS OF A 4'-0" FIXTURE.

AutoCAD SHX Text

WITH FOUR FULL WRAPS AT TOP AND BOTTOM

AutoCAD SHX Text

RECESSED LIGHT FIXTURE

AutoCAD SHX Text

MAIN RUNNER

AutoCAD SHX Text

CROSS TEE

AutoCAD SHX Text

TAB PROVIDED ON THE

AutoCAD SHX Text

FIXTURE OR INSTALL

AutoCAD SHX Text

1/4" CLOSED EYEBOLT

AutoCAD SHX Text

#12 GA. SLACK WIRE

AutoCAD SHX Text

@ 45%%D ANGLE TYPICAL

AutoCAD SHX Text

FRAME

AutoCAD SHX Text

FOUR CORNERS

AutoCAD SHX Text

OF FIXTURE

AutoCAD SHX Text Wall Switch

AutoCAD SHX Text Automatic

AutoCAD SHX Text Wall Switch

AutoCAD SHX Text Automatic

AutoCAD SHX Text Load Red

AutoCAD SHX Text (See installation

AutoCAD SHX Text instuctions)

AutoCAD SHX Text Ground

AutoCAD SHX Text instuctions)

AutoCAD SHX Text (See installation

AutoCAD SHX Text 120V/277V Ground

AutoCAD SHX Text 120V/277V Ground

AutoCAD SHX Text Hot

AutoCAD SHX Text Neutral

AutoCAD SHX Text Ground

AutoCAD SHX Text Blk

AutoCAD SHX Text Neutral

AutoCAD SHX Text Hot

AutoCAD SHX Text Blk

AutoCAD SHX Text Occupancy Sensor

AutoCAD SHX Text Occupancy Sensor

AutoCAD SHX Text Dual Technology

AutoCAD SHX Text Dual Technology

AutoCAD SHX Text Manual Bi-Level Switch

AutoCAD SHX Text Single Switch

AutoCAD SHX Text Load

AutoCAD SHX Text Red

AutoCAD SHX Text Load

AutoCAD SHX Text Load

AutoCAD SHX Text Load

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

VIO

AutoCAD SHX Text

GRY

AutoCAD SHX Text Class 2 0-10 Volt Control Wiring

AutoCAD SHX Text LMRJ Series Pre-Terminated Cables or CAT5e. Free Topology & Splitter Acceptable

AutoCAD SHX Text 120/277

AutoCAD SHX Text Red

AutoCAD SHX Text Hot Blk

AutoCAD SHX Text Neutral Wht

AutoCAD SHX Text Dimming Room Controller LMRC-213 OR EQUAL

AutoCAD SHX Text Vio

AutoCAD SHX Text Gry

AutoCAD SHX Text RJ45 Port (Typical)

AutoCAD SHX Text Dual Technology Occupancy Sensor

AutoCAD SHX Text Wattstopper LMDC-100-U Or Equal

AutoCAD SHX Text Dimming Switch LMDM-101-U Or Equal

AutoCAD SHX Text Lighting

AutoCAD SHX Text Load

AutoCAD SHX Text (a)

AutoCAD SHX Text Lighting

AutoCAD SHX Text Load

AutoCAD SHX Text (b)

AutoCAD SHX Text a

AutoCAD SHX Text 0-10VDC Dimming Ballast or Dimming Driver

AutoCAD SHX Text Lighting

AutoCAD SHX Text Load

AutoCAD SHX Text (c)

AutoCAD SHX Text Dual Technology Occupancy Sensor

AutoCAD SHX Text Wattstopper LMDC-100-U Or Equal

AutoCAD SHX Text See Lighting Plan For Multiple Sensor Locations

AutoCAD SHX Text See Lighting Plan For Multiple Sensor Locations

AutoCAD SHX Text b

AutoCAD SHX Text Equal

AutoCAD SHX Text DW-100 or

AutoCAD SHX Text Equal

AutoCAD SHX Text DW-200 or

AutoCAD SHX Text c

AutoCAD SHX Text Dimming Switch LMDM-101-U Or Equal

AutoCAD SHX Text Dimming Switch LMDM-101-U Or Equal

AutoCAD SHX Text

RJ45 (TYPICAL)

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

AutoCAD SHX Text

VIO

AutoCAD SHX Text

GRY

AutoCAD SHX Text Class 2 0-10 Volt

AutoCAD SHX Text Control Wiring

AutoCAD SHX Text LMRJ Series Pre-Terminated Cables or CAT5e. Free Topology & Splitter Acceptable

AutoCAD SHX Text 120/277

AutoCAD SHX Text Red

AutoCAD SHX Text Hot Blk

AutoCAD SHX Text Neutral Wht

AutoCAD SHX Text Dimming Room Controller LMRC-212 OR EQUAL

AutoCAD SHX Text Vio

AutoCAD SHX Text Gry

AutoCAD SHX Text Lighting

AutoCAD SHX Text Load

AutoCAD SHX Text (d)

AutoCAD SHX Text 0-10VDC Dimming

AutoCAD SHX Text RJ45 Port (Typical)

AutoCAD SHX Text Dual Technology Occupancy Sensor Wattstopper LMDC-100-U Or Equal

AutoCAD SHX Text Dual Technology Occupancy Sensor Wattstopper LMDC-100-U Or Equal

AutoCAD SHX Text Normal Power Sense (Black 18AWG)

AutoCAD SHX Text Normal Neutral (White 18AWG)

AutoCAD SHX Text Normal Switched Sense (Red 18AWG)

AutoCAD SHX Text Emergency Power In (Black 12AWG)

AutoCAD SHX Text Emergency Neutral (White 18AWG)

AutoCAD SHX Text Emergency Power Out (Red 12AWG)

AutoCAD SHX Text "Sensing" Line

AutoCAD SHX Text "Switching" Line

AutoCAD SHX Text Vio

AutoCAD SHX Text Gry

AutoCAD SHX Text 0-10VDC Dimming

AutoCAD SHX Text Emergency Lighting Load (e)

AutoCAD SHX Text Push to Test

AutoCAD SHX Text Cut jumper loop to use with Normally Closed -test switch -fire alarm panel -security panel -other

AutoCAD SHX Text

WATTSTOPPER ELCU-200 OR EQUAL

AutoCAD SHX Text Remote Activation

AutoCAD SHX Text Normal Power

AutoCAD SHX Text Emergency Power

AutoCAD SHX Text Emergency Line 120/277

AutoCAD SHX Text Emergency Neutral

AutoCAD SHX Text

(NORMAL POWER)

AutoCAD SHX Text

(EMERGENCY POWER)

AutoCAD SHX Text Dimming Switch LMDM-101-U Or Equal

AutoCAD SHX Text d

AutoCAD SHX Text e

AutoCAD SHX Text Dimming Switch LMDM-101-U Or Equal

AutoCAD SHX Text

%%UNOTES:

AutoCAD SHX Text RJ45 (Typical)

AutoCAD SHX Text Photosensor LMLS-400/500/600 or Equal

AutoCAD SHX Text

1. SEE LIGHTING PLAN FOR QUANTITY OF DIMMING SWITCH CONTROL & OCCUPANCY SENSOR

AutoCAD SHX Text

2. PROVIDE MOUNTING BRACKET AND JUNCTION BOX TO SECURE CONTROLLER AND SENSORS

AutoCAD SHX Text

3. PROVIDE DIGITAL WIRELESS CONFIGURATION TOOL. WATTSTOPPER LMCT-100-2 OR EQUAL

AutoCAD SHX Text

%%UNOTES:

AutoCAD SHX Text

1. SEE LIGHTING PLAN FOR QUANTITY OF DIMMING SWITCH CONTROL & OCCUPANCY SENSOR

AutoCAD SHX Text

2. PROVIDE MOUNTING BRACKET AND JUNCTION BOX TO SECURE CONTROLLER AND SENSORS

AutoCAD SHX Text

3. PROVIDE DIGITAL WIRELESS CONFIGURATION TOOL. WATTSTOPPER LMCT-100-2 OR EQUAL

AutoCAD SHX Text

520 3RD STREET, SUITE 206, OAKLAND, CA 94607

AutoCAD SHX Text

PHONE: (510) 763-7475

AutoCAD SHX Text

FAX: (510) 763-7033

AutoCAD SHX Text No.10436

TYPICAL VOICE-DATA OUTLET

TYPICAL DATA OUTLET

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

ARCHITECT OF RECORD

BI

M

M ar tin ez B

/6

-1

8-

9_ A.

rv t

2/ 9/

:0

0:

P M

CONCOURSE FEDERAL GROUP

213 SOUTH ROYAL STREET

ALEXANDRIA, VA 22314

GENE KLOW

REMODEL SPECIALTY

CARE - BUILDING 19

VA MARTINEZ

612-18-329

03/26/2021

100% - BID SET

Revisions: Date:

CONSULTING ENGINEERS

F.W. A NC.SSOCIATES,I

SJ/MF FWA TEAM

ES7-2

TELECOM POWER DETAILS AND

DIAGRAMS

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

AutoCAD SHX Text

%%UTELECOM NOTES:

AutoCAD SHX Text

ALL TELEPHONE AND DATA SYSTEM JACKS ARE TO BE EIA/TIA -

AutoCAD SHX Text

568A CATEGORY 6A TYPE RJ-45 (8) PIN MODULAR ASSEMBLIES. EACH

AutoCAD SHX Text

MODULAR JACK ASSEMBLY SHALL ACCEPT ONE 4-PAIR (24 AWG)

AutoCAD SHX Text

CAT 6 DATA GRADE SOLID-TINNED COPPER WIRE, UNSHIELDED

AutoCAD SHX Text

TWISTED-PAIRS (UTP) CABLE WITH COLOR-CODING IDENTIFICATION.

AutoCAD SHX Text

ALL CABLES WILL BE TERMINATED ON THE RACK MOUNTED

AutoCAD SHX Text

MODULAR PATCH PANELS IN THE TELEPHONE/DATA ROOM.

AutoCAD SHX Text

IN COMBINATION JACK ASSEMBLIES, TELEPHONE TERMINATIONS

AutoCAD SHX Text

WILL BE TOP JACKS AND DATA THE BOTTOM JACKS (UNLESS

AutoCAD SHX Text

NOTED OTHERWISE ON SCHEDULES).

AutoCAD SHX Text

LABEL ALL JACK ASSEMBLIES.

AutoCAD SHX Text

CONTRACTOR TO SUBMIT SHOP DRAWINGS FOR ALL DATA

AutoCAD SHX Text

SYSTEMS.

AutoCAD SHX Text

ALL TELEPHONE AND DATA CABLES WILL BE RUN IN CONDUIT

AutoCAD SHX Text

FROM OUTLET TO ACCESSIBLE CEILING SPACE. RUN CABLES

AutoCAD SHX Text

VIA CABLE TRAY TO TELEPHONE DATA CLOSET.

AutoCAD SHX Text 1.

AutoCAD SHX Text 2.

AutoCAD SHX Text 3.

AutoCAD SHX Text 4.

AutoCAD SHX Text 5.

AutoCAD SHX Text

%%UOFFICE OF INFORMATION AND TECHNOLOGY DESIGN AND CONSTRUCTION GUIDANCE

AutoCAD SHX Text

1. GENERAL VA HEALTH CARE SYSTEM

AutoCAD SHX Text

1.1 CODES OF PRACTICE

AutoCAD SHX Text CONDITION OF CONTRACT. IN THE EVENT THE CABLING INSTALLATION IS SUB-CONTRACTED BY THE PRIME

AutoCAD SHX Text CONTRACTOR, THE PRIME CONTRACTOR WILL SUPPLY A COPY OF THESE SPECIFICATIONS TO THE

AutoCAD SHX Text

SUB-CONTRACTOR. THIS REQUIREMENT SHALL COVER ALL LEVELS OF SUB-CONTRACTING.

AutoCAD SHX Text ANY VARIATIONS TO THE ISSUED JOB SPECIFICATION SHALL BE REFERRED FOR APPROVAL TO THE

AutoCAD SHX Text

CONTRACTING OFFICER REPRESENTATIVE (COR).

AutoCAD SHX Text CONTRACTORS SHALL INSTALL ALL CABLE AND CABLING PRODUCTS WITH A PROVEN TRACK RECORD FOR DATA

AutoCAD SHX Text NETWORK CABLING INSTALLATIONS. SUCH INSTALLATIONS SHALL ALSO MEET ALL REQUIREMENTS AS SET OUT

AutoCAD SHX Text

IN THIS SPECIFICATION.

AutoCAD SHX Text UN-TERMINATED "FUTURE CAPACITY" CABLES ARE NOT PERMITTED. ALL INSTALLED CABLES SHALL BE

AutoCAD SHX Text TERMINATED AT EACH END AND DOCUMENTATION, LABELING AND (WHERE APPLICABLE) TEST RESULTS

AutoCAD SHX Text

PROVIDED. THIS APPLIES TO ALL PERMANENTLY INSTALLED CABLE TYPES.

AutoCAD SHX Text

1.2 DOCUMENTATION

AutoCAD SHX Text AT LEAST TWO COPIES OF DOCUMENTS DESCRIBING THE DATA CABLE INSTALLATION SHALL BE PROVIDED. A

AutoCAD SHX Text

COPY TO BE SUPPLIED TO THE COR FOR APPROVAL

AutoCAD SHX Text

1.3 NETWORK EQUIPMENT

AutoCAD SHX Text COR MUST APPROVE THE INSTALLATION OR REMOVAL OF NETWORK HARDWARE EQUIPMENT. NON-VA

AutoCAD SHX Text

STAFF SHALL CARRY OUT SUCH WORK ONLY WITH PRIOR APPROVAL FROM THE COR.

AutoCAD SHX Text

2. UNSHIELDED TWISTED PAIR (UTP) CATEGORY 6A

AutoCAD SHX Text

IEEE 802.3 100BASET UTP LEVEL 6, 24 AWG PLENUM RATED CABLE.

AutoCAD SHX Text

INSULATION - HIGH-SPEED DATA GRADE.

AutoCAD SHX Text

SHEATH - HIGH TEMPERATURE UL DATA GRADE.

AutoCAD SHX Text

2.1 NETWORK CONFIGURATION CONSTRAINTS

AutoCAD SHX Text

EACH SEGMENT COMPRISES A FOUR PAIR CATEGORY 6A CABLE.

AutoCAD SHX Text

PIN ALL 8 CONDUCTORS.

AutoCAD SHX Text

MAXIMUM LINK LENGTH - 90 METERS

AutoCAD SHX Text

2.2 INSTALLATION CONSTRAINTS

AutoCAD SHX Text

2.2.1 INSTALLATION STANDARDS

AutoCAD SHX Text CABLE AND CONNECTING HARDWARE MEETING OR EXCEEDING THE CATEGORY 6A SPECIFICATIONS SHALL

AutoCAD SHX Text

BE USED THROUGHOUT, WITH PAIRS TERMINATED ACCORDING TO THE T568B WIRING SCHEME.

AutoCAD SHX Text

2.2.2 GENERAL REQUIREMENTS

AutoCAD SHX Text THE CABLING SYSTEM SHALL INCLUDE ALL PATCH PANELS, HORIZONTAL CABLES, TRANSITION BLOCKS, AutoCAD SHX Text VERTICAL CABLING, MODULAR JACKS, SYSTEM CABLES, PATCH CABLES, CABLE MANAGEMENT, AND A

AutoCAD SHX Text COMPREHENSIVE LABELING SYSTEM. CABLE TRAYS SHALL BE INSTALLED IN MAIN HALLWAYS IN THE PLACE

AutoCAD SHX Text

OF J-HOOKS.

AutoCAD SHX Text

2.2.3 DATA OUTLETS

AutoCAD SHX Text THE FOLLOWING INFORMATION REPRESENTS A MINIMUM REQUIREMENT FOR THE NUMBER OF UTP OUTLETS

AutoCAD SHX Text

THAT SHALL BE INSTALLED IN EACH TYPE OF WORKSPACE.

AutoCAD SHX Text IF THE CONSTRUCTION AT THE LOCATION OF THE VOICE/DATA OUTLET IS DRYWALL, PROVIDE FLUSH-MOUNTED

AutoCAD SHX Text SINGLE-GANG OUTLET BOXES WITH SIX-PORT BASE PLATES AND APPLICABLE WALL DEVICE FACEPLATES

AutoCAD SHX Text

(CABLE TO BE INSTALLED BEHIND DRYWALL).

AutoCAD SHX Text IF THE CONSTRUCTION AT THE LOCATION OF THE VOICE/DATA OUTLET IS A SOLID WALL, PROVIDE

AutoCAD SHX Text SURFACE-MOUNTED SINGLE-GANG OUTLET BOXES WITH SIX-PORT BASE PLATES AND APPLICABLE WALL

AutoCAD SHX Text DEVICE FACEPLATES (CABLE TO BE INSTALLED IN PLASTIC WALL MOLD EQUIPPED WITH PROTECTIVE

AutoCAD SHX Text

INSULATOR OR SLEEVE).

AutoCAD SHX Text WHERE MODULAR FURNITURE IS USED, THE LOCATION OF THE VOICE/DATA OUTLET WILL BE IN THE

AutoCAD SHX Text BASEBOARD OF THE FURNITURE, WHERE THE NETWORKED EQUIPMENT (COMPUTERS, PRINTERS, ETC) WILL

AutoCAD SHX Text BE LOCATED. PROVIDE FLUSH-MOUNTED SINGLE GANG OUTLET BOXES WITH SIX-PORT BASE PLATES AND

AutoCAD SHX Text APPLICABLE WALL DEVICE FACEPLATES. IF FLUSH-MOUNTED SINGLE-GANG OUTLET BOXES CANNOT BE

AutoCAD SHX Text USED, THEN MODULAR SURFACE MOUNT BOXES WILL BE USED WITH SIX-PORT INSERTS. ALL CABLE RUNS IN

AutoCAD SHX Text

MODULAR FURNITURE WILL BE THROUGH FURNITURE WIRE BASEBOARD DUCTS/CONDUIT.

AutoCAD SHX Text

2.2.4 HORIZONTAL CABLING

AutoCAD SHX Text THE HORIZONTAL WIRING SHALL BE A STAR TOPOLOGY CONNECTING EACH NETWORK OUTLET JACK TO A JACK

AutoCAD SHX Text

ON A PATCH PANEL RACK IN A COMMUNICATIONS ENCLOSURE/ROOM.

AutoCAD SHX Text THE CABLE USED SHALL BE 4-PAIR 100-OHM HIGH PERFORMANCE, 24 AWG SOLID CONDUCTOR, AND

AutoCAD SHX Text UNSHIELDED TWISTED PAIR CABLE, MEETING OR EXCEEDING THE CATEGORY 6A SPECIFICATION.

AutoCAD SHX Text

2.2.5 NETWORK OUTLET AND LABELING

AutoCAD SHX Text

*ETHERNET 568B .5 RJ 45 SHALL BE BLUE AND .6 RJ 45 SHALL BE YELLOW *

AutoCAD SHX Text *VOICE PAIR ONE IN INSERT ONE SHALL BE WHITE AND PAIR TWO IN INSERT TWO SHALL BE WHITE

AutoCAD SHX Text EACH NETWORK OUTLET FACEPLATE SHALL INCORPORATE ONE OR MORE MODULAR, UNIVERSAL RJ45 IDC

AutoCAD SHX Text JACK SOCKETS MEETING OR EXCEEDING THE CATEGORY 6A SPECIFICATION. LABEL EACH JACK AT THIS

AutoCAD SHX Text WALL DEVICE FACEPLATE TO CORRESPOND WITH THE LABEL ON THE PATCH PANEL JACK (N1, N2, ETC.). ALL

AutoCAD SHX Text

NUMBERING SHOULD BE READILY VISIBLE.

AutoCAD SHX Text

2.2.6 CABLE INSTALLATION

AutoCAD SHX Text THE CABLE INTERCONNECTING A NETWORK OUTLET TO THE PATCH PANEL SHALL BE ONE CONTINUOUS

AutoCAD SHX Text LENGTH WITH NO INTERMEDIATE JOINS, SPLICES OR TAPS. EACH CABLE RUNS SHALL BE NO LONGER THAN

AutoCAD SHX Text

262 FEET TOTAL IN LENGTH, FROM START TO FINISH.

AutoCAD SHX Text CABLE TERMINATION ONTO A HORIZONTAL DISTRIBUTION PANEL OR PATCH PANEL SHALL BE UNDERTAKEN IN

AutoCAD SHX Text A MANNER THAT PERMITS ADDITIONAL CABLES TO BE TERMINATED WITHOUT UNDULY DISTURBING

AutoCAD SHX Text

PREVIOUSLY INSTALLED CABLES.

AutoCAD SHX Text EACH VOICE/DATA OUTLET / DEVICE…