S02 - ATTACHMENT 3 - Drawings Vol. 1 of 3.pdf

PDF 16 MB Posted

Attached to
Y1DA--Remodel Specialty Care & Correct HVAC in Bldg. 19 - Martinez VAMC
Solicitation number
36C77621B0021
Issued by

About this file

This federal contract opportunity solicitation seeks a contractor to remodel specialty care and correct HVAC systems in Building 19 at the Martinez Veterans Affairs Medical Center. The selected contractor will be responsible for providing all labor, materials, equipment, supervision and other resources necessary to complete the construction project according to the specifications and drawings in Attachment 3 of the solicitation documentation. The solicitation was issued by the Department of Veterans Affairs Technology Acquisition Center located in Austin, Texas. Interested parties should respond with pricing and qualification information by the response date listed to be considered for the award scheduled on the date provided.

View the file

Other files

File Type Posted
S05 - Att 08e - Existing Equipment (5).jpg JPG image
S05 - Att 08b - Existing Equipment (2).jpg JPG image
S05 - Att 04 - 19_Martinez Floor Plan.pdf PDF
S05 - Att 03 - ICRA_ICCP -- Final.pdf PDF
S05 - Att 08g - Existing Equipment (7).jpg JPG image
S05 - Att 07g - CAD Files - Plumbing (7).zip ZIP file
S05 - Att 07b - CAD Files - Architectural (2).zip ZIP file
S05 - Att 08h - Existing Equipment (8).jpg JPG image
S05 - Att 07f - CAD Files - Mechanical (6).zip ZIP file
S05 - Att 07d - CAD Files - Electrical (4).zip ZIP file
S05 - Att 06 - VAV Pipe Detail.zip ZIP file
S05 - Att 02 - Nurse Call Cut-Sheets Request.pdf PDF
36C77621B0021 0003.pdf PDF
S05 - Att 08d - Existing Equipment (4).jpg JPG image
S05 - Att 07c - CAD Files - Structural (3).zip ZIP file
S05 - Att 07a - CAD Files - Architectural (1).zip ZIP file
S05 - Att 07b - CAD Files - Structual.zip ZIP file
S05 - Att 07e - CAD Files - Fire Protection (5).zip ZIP file
S05 - Att 05 - Martinez B19_RxR_220908.xlsx XLSX spreadsheet
S05 - Att 08a - Existing Equipment (1).jpg JPG image
S05 - Att 08i - Existing Equipment (9).jpg JPG image
S05 - Att 08c - Existing Equipment (3).jpg JPG image
S05 - Att 01 - Technical Questions and Answers 9.9.2022.pdf PDF
S05 - Att 08f - Existing Equipment (6).jpg JPG image
S05 - Att 09 - CAD Files - Chaparral Layouts.zip ZIP file
36C77621B0021 0002.pdf PDF
S04 - Site Visit - Sign-in Sheet.pdf PDF
S06 - SF30 - 36C77621B0021 - Amendment 0001.pdf PDF
S02 - ATTACHMENT 2 - Specifications Vol. 2 of 2.pdf PDF
S02 - ATTACHMENT 9 - Construction Wage Rates.pdf PDF
36C77621B0021.pdf PDF
S02 - ATTACHMENT 10 - Contractor Safety - Environmental Form.docx DOCX document
S02 - ATTACHMENT 5 - Drawings Vol. 3 of 3.pdf PDF
S02 - ATTACHMENT 8 - Limitations on Subcontracting - Construction.docx DOCX document
S02 - ATTACHMENT 4 - Drawings Vol. 2 of 3.pdf PDF
S02 - ATTACHMENT 6 - Contractor Core Work Hours.pdf PDF
S02 - ATTACHMENT 7 - COVID-19 Safety Protocols 12-14-21.pdf PDF
S02 - ATTACHMENT 1 - Specifications Vol. 1 of 2.pdf PDF
Show all 38

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

ARCHITECT OF RECORD

B

IM

/M a rt in e z B

/6

-1

-3

A

.r v t

/3

/2

:5 :0

P

M

GI001

COVER SHEET

CONCOURSE FEDERAL GROUP

213 SOUTH ROYAL STREET

ALEXANDRIA, VA 22314

GENE KLOW

REMODEL SPECIALTY

CARE - BUILDING 19

VA MARTINEZ

612-18-329

03/26/2021

100% - BID SET

SHEET INDEX

VA NORTHERN CALIFORNIA HEALTH CARE SYSTEM

REMODEL SPECIALTY CARE - BUILDING 19

CONSTRUCTION DOCUMENTS - 100% BID SET

MARCH 26, 2021

150 MUIR ROAD, MARTINEZ, CALIFORNIA 94553

PROJECT 612-18-329

DESIGN TEAM

OWNER

ARCHITECT / CONTRACT PRIME

STRUCTURAL ENGINEER

ELECTRICAL ENGINEER

MECHANICAL / PLUMBING

ENGINEER / FIRE PROTECTION

Veterans Association VA Northern California Healthcare System 150 Muir Road, Martinez, CA 94553 Contact: Henry Lapira

Concourse Federal Group 123 South Royal Street Alexandria, Virginia 22314 Contact: Matt Shuba, AIA mshuba@concoursefederal.com

(202) 304-9784

Gregory P. Luth & Associates 3350 Scott Boulevard, Building 48 Santa Clara, California 95054 Contact: Greg Luth, PE greg@gplainc.com

(408) 654-0475

F.W. Associates, Inc.

520 3rd Street, Suite 206 Oakland, California 94607 Contact: Munson Fong mfong@fwa-inc.com

(510) 763-7475

Capital Engineering Consultants 11020 Sun Center Drive, Suite 100 Rancho Cordova, California 95670 Contact: Bryan Johnson bjohnson@capital-engineering.com

(916) 851-3500

12 - PLUMBING

P001 PLUMBING SYMBOLS NOTES & LEGENDS

P002 PLUMBING SCHEDULES & FIXTURES

P500 PLUMBING DETAILS

PL101 ENLARGED PHASE 2 FIRST FLOOR UNDERGROUND PLAN EAST

PL102 ENLARGED PHASE2 FIRST FLOOR VENT PLAN EAST

PL201 ENLARGED PHASE 1 SECOND FLOOR WASTE PLAN

PL202 ENLARGED PHASE 2 FIRST FLOOR SS NEW PLAN

PL203 ENLARGED PHASE 1 SECOND FLOOR VENT PLAN

PL204 ENLARGED PHASE 2 SECOND FLOOR VENT NEW WORK PLAN

PLD100 ENLARGED PHASE 2 FOUNDATION SS DEMOLITION PLAN EAST

PLD201 ENLARGED PHASE 1 SECOND FLOOR SS DEMOLTION PLAN

PLD202 ENLARGED PHASE 2 SECOND FLOOR SS DEMOLITION PLAN

PP101 ENLARGED PHASE 2 FIRST FLOOR H&CW NEW PLAN EAST

PP102 ENLARGED PHASE 1 FIRST FLOOR H&CW NEW PLAN WEST

PP201 ENLARGED PHASE 1 SECOND FLOOR H&CW NEW PLAN

PP202 ENLARGED PHASE 2 SECOND FLOOR H&CW NEW PLAN

PPD101 ENLARGED PHASE 2 FIRST FLOOR H&CW DEMOLITION PLAN EAST

14 - ELECTRICAL

ES0-1 ELECTRICAL SYMBOL LEGEND, ABBREVIATIONS, GENERAL NOTES

ES0-2 FIRST FLOOR REFERENCE PLAN - ELECTRICAL

ES0-3 SECOND FLOOR REFERENCE PLAN - ELECTRICAL

ES1-1 PHASE 2 FIRST FLOOR - DEMOLITION ELECTRICAL

ES1-2 PHASE 1 SECOND FLOOR - DEMOLITION ELECTRICAL

ES1-3 PHASE 2 SECOND FLOOR - DEMOLITION ELECTRICAL

ES2-1 PHASE 2 FIRST FLOOR - LIGHTING

ES2-2 PHASE 1 SECOND FLOOR - LIGHTING

ES2-3 PHASE 2 SECOND FLOOR - LIGHTING

ES3-1 PHASE 2 FIRST FLOOR - POWER

ES3-2 PHASE 1 SECOND FLOOR - POWER

ES3-3 PHASE 2 SECOND FLOOR - POWER

ES3-4 ROOF PLAN - ELECTRICAL

ES4-1 PHASE 2 FIRST FLOOR - FIRE ALARM

ES4-2 PHASE 1 SECOND FLOOR - FIRE ALARM

ES4-3 PHASE 2 SECOND FLOOR - FIRE ALARM

ES5-1 SINGLE LINE DIAGRAM FOR REFERENCE

ES6-1 PANEL SCHEDULE

ES7-1 DETAILS AND DIAGRAMS

ES7-2 TELECOM POWER DETAILS AND DIAGRAMS

ES7-3 TELECOM DETAILS AND DIAGRAMS

14 - MECHANICAL

M001 MECHANICAL SYMBOLS NOTES & LEGENDS

M002 MECHANICAL SCHEDULES

M003 MECHANICAL AIRFLOW

M100 ENLARGED PHASE 1 FIRST FLOOR EXHAUST RISER NEW WORK PLAN

M101 ENLARGED PHASE 2 FIRST FLOOR HVAC NEW WORK PLAN EAST

M201 ENLARGED PHASE 1 SECOND FLOOR HVAC NEW WORK NORTH

M202 ENLARGED PHASE 1 SECOND FLOOR HVAC NEW WORK PLAN

M203 ENLARGED PHASE 2 SECOND FLOOR HVAC NEW WORK PLAN

M300 ENLARGED ROOF HVAC NEW WORK PLAN

M500 MECHANICAL DETAILS

M501 MECHANICAL DETAILS

M600 MECHANICAL CONTROLS

M601 MECHANICAL CONTROLS

MA100 ENLARGED FIRST FLOOR AIR BALANCE PLAN

MA200 ENLARGED SECOND FLOOR AIR BALANCE PLAN

MD101 ENLARGED PHASE 2 FIRST FLOOR HVAC DEMOLITION PLAN EAST

MD201 ENLARGED PHASE 1 SECOND FLOOR HVAC DEMOLITION PLAN NORTH

MD202 ENLARGED PHASE 1 SECOND FLOOR HVAC DEMOLITION PLAN

MD203 ENLARGED PHASE 2 SECOND FLOOR HVAC DEMOLITION PLAN

MD300 ENLARGED ROOF HVAC DEMOLITION PLAN

MP101 ENLARGED PHASE 1 FIRST FLOOR MECH PIPING NEW WORK PLAN EAST

MP201 ENLARGED PHASE 1 SECOND FLOOR MECH PIPING NEW WORK PLAN

MP202 ENLARGED PHASE 2 SECOND FLOOR MECH PIPING NEW WORK PLAN

MPD101 ENLARGED PHASE 2 FIRST FLOOR MECH PIPING DEMOLITION PLAN EAST

MPD201 ENLARGED PHASE 1 SECOND FLOOR MECH PIPING DEMOLITION PLAN

MPD202 ENLARGED PHASE 2 SECOND FLOOR MECH PIPING DEMOLITION PLAN

MZ100 FIRST FLOOR AHU ZONING PLAN

MZ101 FIRST FLOOR TERMINAL UNIT ZONING PLAN

MZ102 FIRST FLOOR EXHAUST ZONING PLAN

MZ200 SECOND FLOOR AHU ZONING PLAN

MZ201 SECOND FLOOR TERMINAL UNIT ZONING PLAN

MZ202 SECOND FLOOR EXHAUST ZONING PLAN

01 - GENERAL

GI002 PROJECT TEAM, PROJECT DATA, ABBREVIATIONS, SYMBOLS AND MATERIALS

GI003 FLOOR 1 FIRE AND SAFETY INFORMATION

GI004 FLOOR 2 FIRE AND SAFETY INFORMATION

GI005 FIRST FLOOR PHASING PLAN

GI006 SECOND FLOOR PHASING PLAN

GI100 ADA CLEARANCES AND TYPICAL MOUNTING HEIGHTS

07 - STRUCTURAL

SE103 ENLARGED PHASE 2 SECOND FLOOR PLAN

08 - ARCHITECTURE

AW107 SIGN TYPE DETAILS

AD101 ENLARGED PHASE 2 FIRST FLOOR DEMOLITION PLAN - EAST

AD102 ENLARGED PHASE 1 SECOND FLOOR DEMOLITION PLANS

AD103 ENLARGED PHASE 2 SECOND FLOOR DEMOLITION PLAN

AD111 ENLARGED PHASE 2 FIRST FLOOR REFLECTED CEILING DEMOLITION PLAN - EAST

AD112 ENLARGED PHASE 1 SECOND FLOOR REFLECTED CEILING DEMOLITION PLANS

AD113 ENLARGED PHASE 2 SECOND FLOOR REFLECTED CEILING DEMOLITION PLAN

AD401 ENLARGED SECOND FLOOR EOS DEMOLITION PLANS

AE101 ENLARGED PHASE 2 FIRST FLOOR PLAN - EAST

AE102 ENLARGED PHASE 1 SECOND FLOOR PLANS

AE103 ENLARGED PHASE 2 SECOND FLOOR PLAN

AE201 ENLARGED PHASE 2 FIRST FLOOR REFLECTED CEILING PLAN - EAST

AE202 ENLARGED PHASE 1 SECOND FLOOR REFLECTED CEILING PLANS

AE203 ENLARGED PHASE 2 SECOND FLOOR REFLECTED CEILING PLAN

AE301 INTERIOR ELEVATIONS

AE302 INTERIOR ELEVATIONS

AE303 INTERIOR ELEVATIONS

AE400 PERSPECTIVES - 1ST FLOOR

AE401 PERSPECTIVES - 2ND FLOOR

AE501 INTERIOR PLAN DETAILS

AE502 INTERIOR DETAILS

AE503 CEILING AND SOFFIT DETAILS

AE504 CASEWORK DETAILS

AE601 DOOR AND WINDOW SCHEDULES

AE602 EQUIPMENT SCHEDULE

AE603 EQUIPMENT SCHEDULE

AE604 EQUIPMENT SCHEDULE

AE605 PARTITION TYPES

AE606 PARTITION HEAD DETAILS AND HORIZONTAL RATED ENCLOSURE

AE701 PARTITION DETAILS

AE702 BACKING PLATE SCHEDULE AND WALL PROTECTION DETAILS

AE703 DOOR AND WINDOW DETAILS

AF101 ENLARGED PHASE 2 FIRST FLOOR FINISH PLAN - EAST

AF102 ENLARGED PHASE 1 & 2 SECOND FLOOR FINISH PLANS

AI101 ENLARGED PHASE 2 FIRST FLOOR FURNITURE / EQUIPMENT PLAN - EAST

AI102 ENLARGED PHASE 1 & 2 SECOND FLOOR FURNITURE / EQUIPMENT PLANS

AW101 ENLARGED PHASE 2 FIRST FLOOR WAYFINDING PLAN - EAST

AW102 ENLARGED PHASE 1 & 2 SECOND FLOOR WAYFINDING PLANS

AW103 SIGNAGE SCHEDULE & SIGNAGE FINISHES

AW104 SIGN TYPE DETAILS

AW105 SIGN TYPE DETAILS

AW106 SIGN TYPE DETAILS

11 - FIRE PROTECTION

FP001 FIRE PROTECTION SYMBOLS, NOTES AND ABBREVIATIONS

FP101 ENLARGED PHASE 2 FIRST FLOOR FIRE PROTECTION NEW PLAN EAST

FP201 ENLARGED PHASE 1 SECOND FLOOR FIRE PROTECTION NEW WORK PLAN

FP202 ENLARGED PHASE 2 SECOND FLOOR FIRE PROTECTION NEW WORK PLAN

FPD101 ENLARGED PHASE 2 FIRST FLOOR FIRE PROTECTION DEMOLTION PLAN EAST

FPD201 ENLARGED PHASE 1 SECOND FLOOR FIRE PROTECTION DEMOLITION PLAN

FPD202 ENLARGED PHASE 2 SECOND FLOOR FIRE PROTECTION DEMOLITION PLAN

ARCHITECT / CONSULTANT

MEI ARCHITECTS

949 Grant Avenue San Francisco, CA 94108 Contact: Steven J. Juergens, AIA, NCARB, LEED AP sjuergens@meiarchitects.com

(628) 201-4022

Building 19 Outpatient Clinic

VA Martinez

SITE MAP

Revisions: Date:

CONCRETE

EARTH

GYPSUM BOARD

BATT OR ACOUSTICAL

INSULATION AS NOTED

RIGID INSULATION

MEDIUM DENSITY FIBERBOARD

ALUMINUM

STUCCO

PLYWOOD

PORCELAIN

PLASTER

STEEL

D

OFFICE

OFFICE

AS2-1

A

SYMBOLS

INTERIOR ELEVATION(S)

ROOM NAME

NOT SHOWN.)

ROOM IDENTIFICATION, TYPE 1

CEILING

WALLS/WAINSCOT

ROOM MATERIAL CODES

SHEET WHERE ELEVATION IS

NO ARROWS MEANS ELEVATION

(UNFOLD ELEVATIONS CLOCKWISE

ELEVATION IDENTIFICATION

DRAWN.

DOOR SYMBOL

DOOR MARK

DRAWING NUMBER

DISCIPLINE PREFIX

SHEET WHERE DETAIL IS DRAWN.

DETAIL IDENTIFICATION

HARDWARE GROUP

DETAIL

ROOM IDENTIFICATION, TYPE 2

B12

5-1

9-1

B12

1A1

ROOM NUMBER

ROOM NAME

ROOM NUMBER

(E) COLUMN LINE W/

COLUMN DESIGNATIONS

REVISION

CLOUD AROUND REVISION

DIMENSION LINES

CENTERLINE OF

COLUMN OR STUD

CENTERLINE OF OPENING

FACE OF FINISH

SPRINKLER HEAD

SMOKE DETECTOR

OPTIONAL

B1

TYPICAL FURRING OR

PARTITION TYPE, SEE DWG.

A9-1

U.O.N.

GROUP NUMBER

1.1 WINDOW TYPE

3-1

SHEET WHERE DETAIL IS DRAWN.

SECTION IDENTIFICATION

SECTION

CENTERLINE OF OPENING

TYPICAL PARTITION

LIGHTING FIXTURE

24" X 48", TYPE A2

WALLS BASE

MECHANICAL CEILING RETURN /

EXHAUST REGISTER

EXISTING WALL / PARTITION /

FURRING TO REMAIN

AREA NOT IN SCOPE OF

WORK

A

(N) COLUMN LINE W/

COLUMN DESIGNATIONS

(N) ONE-HOUR FIRE RATED

RESISTING WALL OR PARTITION

LIGHTING FIXTURE

24" X 48", TYPE A

LIGHTING FIXTURE

24" X 24"

LIGHTING FIXTURE

12" X 48"

CORNER GUARD

SOUND INSULATION

EXISTING WALL OR

PARTITION TO BE REMOVED

(E) ONE-HOUR FIRE RATED

RESISTING WALL OR PARTITION

EXISTING WALL FINISHES OR

CLADDING TO BE REMOVED,

STRUCTURE OF WALL TO

REMAIN

DOOR TO BE DEMOLISHED

(E) DOOR TO REMAIN

(N) DOOR

(E) COLUMN TO HAVE

FURRING REMOVED FOR

(N) CONNECTIONS,

COLUMN TO REMAIN

EXIT SIGN

(E) COLUMN AND (E)

FURRING TO REMAIN

DOWNLIGHT FIXTURE

SPOT ELEVATION

MECHANICAL CEILING

DIFFUSER / SUPPLY

SECURITY METAL MESH IN PARTITION

ABBREVIATIONS

TYP.

THRES.

S.

RM.

R.H.

REINF.

REQ.

REF.

STD.

SIM.

SHR.

THK.

T.B.

T.C.

TEL.

STOR.

STRL.

STL.

N.I.C.

NO. or #

N.T.S.

N.R.

OPNG.

OPP.

O.F.C.I

O.A.

O.C.

PLYWD.

PT.

PL.

QTY.

PTN.

VERT.

V.I.F.

W.C.

WD.

W/O

W.

W/

WP.

N.

U.O.N.

CEM.

DWG(S).

CONC.

CONT.

CORR.

CPT.

CTSK.

CNTR.

CLG.

CLO.

CLR.

CER.

DET.

DIA.

DIM.

DN.

DR.

CTR.

ADJ.

A.F.F.

ARCH.

(N)

A.B.

ADD.

(E)

BLKG.

BM.

BOT.

CAB.

BD.

BLDG.

MTD.

INC.

INFO.

HGT.

INT.

JT.

INSUL.

H.C.

MIN.

MISC.

MAX.

KIT.

LAB.

or H.

EA.

EQ.

EXT.

F.A.

F.D.

FDN.

FIN.

FIXT.

EL.

FPRF.

FLUOR.

F.O.F.

F.O.S.

FL.

E.

L

ACOUST.

A.P.

BKG.

BLK.

C.G.

C.L.

COL.

CONSTR.

DISP.

E.J.

ELEC.

ELEV.

ENCL.

ENGR.

E.P.B.

EQPT.

EXP.

E.W.C.

F.E.

F.E.C.

F.H.C.

FT.

F.S.

HDWD.

H.M.

HORIZ.

HR.

I.D.

LAM.

LT.

MAT.

MECH.

MET.

MFR.

NOM.

O.D.

OFF.

O.H.

P. LAM.

PR.

P.T.D.

R.C.P.

REFR.

RGTR.

RESIL.

R.O.

SCHED.

SECT.

SHT.

S.C.

SPEC.

SQ.

S.ST.

SUSP.

T.P.B.

VEST.

W.O.

WT.

W.R.

M.D.F.

(RL)

C.O.

E.B.

EMER.

EXST.

HDWE.

GYP.

GA.

GALV.

G.B.

GL.

DVA

Vertical

Noted

Wood

West

With

Unless Otherwise

Verify In Field

Without

Water Closet

Waterproof

Typical

Threshold

Robe Hook

Top of Curb

Reinforced

Required

Room

Reference

Standard

Similar

Shower

South

Storage

Towel Bar

Telephone

Structural

Thick

Steel

Not In Contract

Not To Scale

Owner Furnished Contractor Installed

Number

On Center

Opening

Opposite

Overall

Non Rated

Plywood

Partition

Quantity

Point

Plate

North

Cement

Drawing(s) Mounted

Ceiling

Closet

Clear

Concrete

Continuous

Corridor

Ceramic

Carpet

Countersunk

Counter

Detail

Diameter

Dimension

Down

Door

Center

Insulation

Height

Incandescent

Information

Hollow Core

Interior

Joint

Maximum

Minimum

Kitchen

Laboratory

Miscellaneous

Each

At

Centerline

Existing

New

Adjustable

Architectural

Board

Building

Blocking

Beam

Anchor Bolt

Additional

Bottom

Cabinet

Above Finished Floor

Equal

Exterior

Elevation

Finish

Fixture

Fire Alarm

Floor Drain

Foundation

Fluorescent

Face of Finish

Face of Studs

Fireproof

Floor

And

East

Diameter

Angle

Acoustical

Access Panel

Backing

Block

Corner Guard

Center Line

Column

Construction

Dispenser

Expansion Joint

Electrical

Elevator

Enclosure

Engineer

Electrical Panelboard

Equipment

Expansion

Electric Water Cooler

Fire Extinguisher

Fire Extinguisher

Fire Hose Cabinet

Foot or Feet

Floor Sink

Hardwood

Hollow Metal

Horizontal

Hour

Inside Diameter

Laminate

Light

Material

Mechanical

Metal

Manufacturer

Nominal

Overflow Drain

Office

Opposite Hand

Plastic Laminate

Pair

Paper Towel

Reflective Ceiling Plan

Refrigerator

Register

Resilient

Rough Opening

Schedule

Section

Sheet

Solid Core

Specification

Square

Stainless Steel

Suspended

Telephone

Vestibule

Where Occurs

Weight

Water Resistant

Medium Density

Relocated Existing

Pound or Number

Cased Opening

Expansion Bolt

Emergency

Existing

Hardware

Gypsum

Gauge

Galvanized

Grab bar

Glass

Cabinet

Fiberboard

Dispenser

Panelboard

Department of Veterans Affairs

MATERIALS U.O.N. GENERAL NOTES

1.

LOCATIONS OF ALL UTILITY LINES (DUCTS, PIPES, CONDUITS, AND OTHER OVERHEAD OBSTRUCTIONS) SHOWN ARE APPROXIMATE. COORDINATE ALL SUPPORT SYSTEMS SO AS NOT TO INTERFERE WITH EACH OTHER. PROVIDE ADDITIONAL BRACING AS NECESSARY TO COMPLETE THE INSTALLATION AT NO

INCREASE TO THE CONTRACT SUM.

PROVIDE SEPARATE SHOP DRAWINGS FOR FIRE SPRINKLER SYSTEM, SUBMIT SPRINKLER SYSTEM

SUBMITTAL INCLUDING SHOP DRAWINGS, PRODUCT DATA, HYDRAULIC CALCULATIONS, ETC. TO

DEPARTMENT OF VETERANS AFFAIRS FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION.

SPRINKLER SYSTEM SHALL BE DESIGNED IN ACCORDANCE WITH TITLE 24, CCR PART 2, CHAPTER 38

AND NFPA 13, 2019 EDITION. AT ACOUSTICAL CEILING TILE LOCATIONS, LOCATE ALL SPRINKLER

HEADS AT CENTER OF CEILING TILES, UNLESS OTHERWISE NOTED.

2.

IN ALL BUILDING CONSTRUCTION AREAS, SEAL ALL PENETRATIONS SUCH AS DUCTS, CONDUITS, PIPES, ETC. AT FIRE RESISTIVE RATED PARTITIONS AND FLOOR/CEILING ASSEMBLIES, WHETHER SHOWN OR NOT AT NO CHANGE TO THE CONTRACT SUM. USE SEALANT TYPE TO MAINTAIN PROPER FIRE RESISTIVE RATING OF THE PENETRATED ASSEMBLIES. ALL PENETRATIONS AT FIRE RESISTIVE RATED PARTITIONS OR FLOOR/CEILING ASSEMBLIES SHALL BE IN ACCORDANCE WITH THE APPROPRIATE U.L. LISTED

APPROVED SYSTEMS.

3.

IF CONTRACTOR PROPOSED ALTERNATE CONSTRUCTION DETAILS AND ARE REVIEWED BY DEPARTMENT OF VETERANS AFFAIRS, CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS AND TIME DELAYS

RESULTING FROM CONTRACTOR'S PROPOSED ALTERNATE CONSTRUCTION DETAILS WHICH AFFECT

OTHER PARTS OF THE WORK OR THE WORK OF SEPARATE CONTRACTORS.

4.

FIRE PROTECTION AT FIRE RESISTIVE RATED WALLS AND PARTITIONS:

A. NO ELECTRICAL BOXES SHALL BE LOCATED BACK TO BACK WITHIN 2'-0" MEASURED

HORIZONTALLY, ON FIRE RESISTIVE RATED PARTITION. IF LOCATED WITHIN 2'-0" EACH

ELECTRICAL BOX SHALL BE SEPARATED WITH FIRE RESISTIVE RATED GYPSUM BOARD

AROUND FIVE SIDES.

B. ANY ELECTRICAL BOX LARGER THAN 16 SQUARE INCHES SHALL BE PROTECTED WITH FIRE

RESISTIVE RATED GYPSUM BOARD AROUND FIVE SIDES.

C. FOR ANY 100 SQUARE FEET OF FIRE RESISTIVE RATED PARTITION AREA, THE ALLOWABLE

AGGREGATED AREA FOR UTILITY BOXES SHALL NOT EXCEED 100 SQUARE INCHES.

PROVIDE SEPARATE SHOP DRAWINGS FOR FIRE ALARM SYSTEM, SUBMIT FIRE ALARM SUBMITTAL

INCLUDING SHOP DRAWINGS AND PRODUCT DATA TO DEPARTMENT OF VETERAN AFFAIRS FOR

REVIEW AND APPROVAL PRIOR TO INSTALLATION. PROVIDE LISTING NUMBER FOR ALL COMPONENTS

IN SUBMITTAL.

PROJECT DATA

VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA

NATIONAL CAD STANDARD APPLICATION GUIDE, AND OTHER

GUIDANCE ON THE TECHNICAL INFORMATION LIBRARY (TIL).

2018 INTERNATIONAL BUILDING CODE (IBC)

VA SEISMIC DESIGN REQUIREMENTS, H-18-8

NFPA 101 LIFE SAFETY CODE 2018 EDITION

OCCUPATIONAL, SAFETY AND HEALTH ADMINISTRATION (OSHA)

STANDARDS

NATIONAL ELECTRICAL CODE (NEC)

NATIONAL STANDARD PLUMBING CODE (NSPC)

ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARD (ABAAS)

INCLUDING VA SUPPLEMENT, BARRIER FREE DESIGN GUIDE

NFPA NATIONAL FIRE CODES WITH THE EXCEPTION OF NFPA 5000

AND NFPA 900

OCCUPANCY

CLASSIFICATION: GROUP B

1st FLOOR 3,645 SQUARE FEETPROJECT GROSS AREA:

FIRE PROTECTION: FULLY SPRINKLERED

2nd FLOOR 5,503 SQUARE FEET

APPLICABLE BUILDING CODES:

SAFETY CODE FOR ELEVATORS AND ESCALATORS, AMERICAN

SOCIETY OF MECHANICAL ENGINEERS (ASME) A17.1.

BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE,

AMERICAN CONCRETE INSTITUTE AND COMMENTARY (ACI 318)

MANUAL OF STEEL CONSTRUCTION, LOAD AND RESISTANCE

FACTOR DESIGN SPECIFICATIONS FOR STRUCTURAL STEEL

BUILDINGS, AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)

VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY - ASHRAE

STANDARD 62.1- 2004

SAFETY STANDARD FOR REFRIGERATION SYSTEMS - ASHRAE

STANDARD 15 - 2007

EXISTING BUILDING DATA

OCCUPANCY TYPE:

CONSTRUCTION TYPE:

FIRE PROTECTION:

NO. OF STORIES:

AMBULALTORY CARE

TYPE II-000

FULLY SPRINKLERED

TWO STORIES

EXISTING BUILDING

GROSS FLOOR AREA:

MINIMUM FIRE RESISTIVE REQUIRMENTS:

ELEMENT RATING

BEARING WALLS, EXTERIOR 0-HOUR

BEARING WALLS, INTERIOR 0-HOUR

NON-BEARING WALLS, INTERIOR 0-HOUR

STRUCTURAL FRAME 0-HOUR

STRUCTURAL FRAME, ROOF ONLY 0-HOUR

SHAFT ENCLOSURES 0-HOUR

FLOORS AND FLOOR/CEILINGS 0-HOUR

ROOFS AND ROOF/CELINGS 0-HOUR

HORIZONTAL EXIT 0-HOUR

HAZARDOUS AREA SEPARATIONS

SOILED LINEN AREAS 1-HOUR

STORAGE ROOM >100 FT 1-HOUR

MAXIMUM TRAVEL DISTANCE TO EXITS

(NFPA 101, CHAPTER 21)

DEAD-END CORRIDORS (21.2.5.2) 50 FT

COMMON PATH OF TRAVEL (21.2.5.3.1) 100 FT

OVERALL DISTANCE TO EXIT (21.2.6.2) 200 FT

91,684 SQUARE FEET

T.B.R. To Be Removed

U.O.N.

MARTINEZ B19 SPECIALTY CARE INTERIOR REMODEL:

A.H.U. Air Handling Unit

L.P. Low Point

H.P. High Point

S.S.D.

See Structural Drawing

5.

THE CONSTRUCTION HOURS SHALL BE MONDAY THROUGH FRIDAY FROM 5:00 PM TO 6:00 AM,

SATURDAY AND SUNDAY ALL DAY UNLESS OTHERWISE NOTED. VA STAFF TO BE PRESENT AT ALL

TIMES.

6.

7.

CONF. Conference

MEMB. Membrane

R.D. Roof Drain

S.O.G. Slab On Grade

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

ARCHITECT OF RECORD

B

IM

/M a rt in e z B

/6

-1

-3

A

.r v t

/3

/2

:5 :0

P

M

GI002

PROJECT TEAM, PROJECT DATA,

ABBREVIATIONS, SYMBOLS AND

MATERIALS

CONCOURSE FEDERAL GROUP

213 SOUTH ROYAL STREET

ALEXANDRIA, VA 22314

GENE KLOW

REMODEL SPECIALTY

CARE - BUILDING 19

VA MARTINEZ

612-18-329

03/26/2021

100% - BID SET

DESIGN NARRATIVE

Project scope consists of developing construction documents for the renovation of existing building space for specialty care services at Martinez, Building 19. Scope will include expanding specialty clinical services by renovating existing space vacated by Hematology/Oncology and Pharmacy Services who have moved to a newly renovated space within Building 19.

The work presented herein is to be constructed in two distinct phases. Specifically, all construction noted as "Phase 1" in these documents must be completed, operational and approved by the COR prior to the start of any work described in these documents as "Phase 2."

E.O.S. Edge Of Slab

RAD. Radius

PERP. Perpendicular

C.J. Construction Joint

(E) ELEV 2

(E) ELEV 1

TEAM ROOM

B145B

WS WAITING

B170

PC EXAM

B132

PC EXAM

B133

LAB/PC TOILET

B131

PC EXAM

B146

PC EXAM

B145

BLOOD DRAW

B130

PC Exam B144A

PC EXAM

B143A

WS CONSULT

B175

PC EXAM

B143

PC EXAM

B144

RECEPTION/GREETER

B170A

WS EXAM

B173

WS TOILET

B174

HAC

B180

WS TOILET

B171A

EXTERIOR

COURTYARD

TO

TA

L D

IS

TA

N C

E T

O E

X

IT

: 1

'-0

TO

TA

L D

IS

TA

N C

E T

O E

X

IT

: 2

'-4

POINT A

WS PROCEDURE

B171

SOILED UTILITY

B172

5 5 10 15 20 25 30

3/32" = 1'-0"

FEETSCALE

BREAKROOM

B145A

FEC

FEC

FEC

FIRE EXTINGUISHER CABINET

EXIT PATH

EXIT W/ NO. OF OCCUPANTS

1-HOUR SMOKE PARTITION

1-HOUR FIRE PARTITION

2-HOUR FIRE PARTITION

NOT IN SCOPE OF WORK

ASSEMBLY USE GROUP

15 SF PER OCCUPANT

AMBULATORY CARE DEPARTMENTS

150 SF PER OCCUPANT

DIRECTION OF TRAVEL

3/32" = 1'-0"

FIRST FLOOR FIRE SAFETY, EXIT PLAN

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

ARCHITECT OF RECORD

B

IM

/M a rt in e z B

/6

-1

-3

A

.r v t

/3

/2

:5 :1

P

M

GI003

FLOOR 1 FIRE AND SAFETY

INFORMATION

CONCOURSE FEDERAL GROUP

213 SOUTH ROYAL STREET

ALEXANDRIA, VA 22314

GENE KLOW

REMODEL SPECIALTY

CARE - BUILDING 19

VA MARTINEZ

612-18-329

03/26/2021

100% - BID SET

EGRESS LEGEND

CODE ANALYSIS

EXIT DISCHARGE A

EXIT

DISCHARGE B

1. AREA OF WORK IS FULLY SPRINKLERED PER NFPA 13.

SEE FIRE PROTECTION SHEET FP001 FOR MORE

INFORMATION.

2. AREA OF WORK IS FULLY ALARMED PER NFPA 72. SEE

FIRE PROTECTION SHEET FP001 FOR MORE

INFORMATION AND EF1-1 FOR ALARM LOCATIONS.

3. ALL INFORMATION RELATING TO FIRE RATED

CONSTRUCTION, AND EXITING WERE BASED ON

EXISTING DRAWINGS PROVIDED BY DEPARTMENT OF

VETERAN AFFAIRS. THE ARCHITECT WILL NOT BE

RESPONSIBLE FOR ACCURACY OR FOR

INTERPRETATION OF INFORMATION ON PREVIOUS

DRAWINGS.

4. SEE SHEET ES2-1, ES2-2, AND ES2-3 FOR EXIT SIGN

LOCATIONS.

CODE NOTES

N

KEY PLAN

Floor 1

PROPOSED OCCUPANCY EXISTING OCCUPANCY

AMBULATORY CARE AND ASSEMBLY USE AMBULATORY CARE AND ASSEMBLY USE

AMBULATORY CARE USE: AMBULATORY CARE USE:

4376 SQUARE FEET AT 150 SF / OCCUPANT 4776 SQUARE FEET AT 150 SF / OCCUPANT

30 OCCUPANTS 32 OCCUPANTS

ASSEMBLY USE: ASSEMBLY USE:

480 SQUARE FEET AT 15 SF / OCCUPANT 440 SQUARE FEET AT 15 SF / OCCUPANT

32 OCCUPANTS 30 OCCUPANTS

TOTAL OCCUPANT LOAD 62 OCCUPANTS (NFPA 101 TABLE 7.3.1.2) TOTAL OCCUPANT LOAD 62 OCCUPANTS

NO CHANGE IN OCCUPANCY

EGRESS

PRIMARY EXIT DISCHARGES FOR AREA OF WORK ARE 'EXIT DISCHARGE A' AND 'EXIT DISCHARGE B.'

EXIT DISCHARGE A:

DOOR: 6'-4" WIDE, 380 CAPACITY

CORRIDOR: 6'-1" WIDE, 365 CAPACITY

EXIT DISCHARGE B:

DOOR: 5'-4" WIDE, 320 CAPACITY

CORRIDOR: 14'-3" WIDE, 855 CAPACITY (NFPA 101 TABLE 7.3.3.1)

COMMON PATH OF TRAVEL FROM POINT A: 39' - 0"

MAXIMUM COMMON PATH OF TRAVEL: 100 FT (NFPA 101 21.2.5..3.1)

ELEV 2

CHARTING

C201

BREAK ROOM

B208

MD TECH WKSTN

B206

EXAM/ TREATMENT 7

B207

CORRIDOR

PRE-SCREENING/ EXAM 2

B202

CATARACT SURGERY

TESTING

B213

EXAM/ TREATMENT 9

B209

EXAM/ TREATMENT 8

B210

VISUAL FIELD

B212

PRE-SCREENING/ EXAM 3

B203

WAITING

B349

RECEPTION - EYE CLINIC

B216A

WAITING

B204

PRE-SCREENING/ EXAM 1

B201

POINT A

POINT B

ST-2

ST-3

PROCEDURE

B214A

EXAM

B214B

EXAM

B214E

EXAM

B214G

EXAM

B214I

TEAM ROOM

B214J

ENT EXAM

B214K

OCT IMAGING/FUNDUS

PHOTO

B211

CLEAN UTILITY / OMNI

B214F

TOILET

B214H

SOILED UTILITY

B214L

OFFICE

B214D

OFFICE

B214C

CORRIDOR

CORRIDOR

CORRIDOR

5 5 10 15 20 25 30

3/32" = 1'-0"

FEETSCALE

FEC

FEC

FEC

FIRE EXTINGUISHER CABINET

EXIT PATH

EXIT W/ NO. OF OCCUPANTS

1-HOUR SMOKE PARTITION

1-HOUR FIRE PARTITION

2-HOUR FIRE PARTITION

NOT IN SCOPE OF WORK

ASSEMBLY USE GROUP

15 SF PER OCCUPANT

AMBULATORY CARE DEPARTMENTS

150 SF PER OCCUPANT

DIRECTION OF TRAVEL

3/32" = 1'-0"

SECOND FLOOR FIRE SAFETY, EXIT PLAN

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

ARCHITECT OF RECORD

B

IM

/M a rt in e z B

/6

-1

-3

A

.r v t

/3

/2

:5 :2

P

M

GI004

FLOOR 2 FIRE AND SAFETY

INFORMATION

CONCOURSE FEDERAL GROUP

213 SOUTH ROYAL STREET

ALEXANDRIA, VA 22314

GENE KLOW

REMODEL SPECIALTY

CARE - BUILDING 19

VA MARTINEZ

612-18-329

03/26/2021

100% - BID SET

EGRESS LEGEND

CODE ANALYSIS

PROPOSED OCCUPANCY EXISTING OCCUPANCY

AMBULATORY CARE AND ASSEMBLY USE AMBULATORY CARE AND ASSEMBLY USE

AMBULATORY CARE USE: AMBULATORY CARE USE:

5135 SQUARE FEET AT 150 SF / OCCUPANT 5383 SQUARE FEET AT 150 SF / OCCUPANT

35 OCCUPANTS 36 OCCUPANTS

ASSEMBLY USE: ASSEMBLY USE:

502 SQUARE FEET AT 15 SF / OCCUPANT 254 SQUARE FEET AT 15 SF / OCCUPANT

35 OCCUPANTS 17 OCCUPANTS

TOTAL OCCUPANT LOAD 70 OCCUPANTS (NFPA 101 TABLE 7.3.1.2) TOTAL OCCUPANT LOAD 53 OCCUPANTS

INCREASE OF 17 OCCUPANTS

EGRESS

PRIMARY EXITS FOR AREA OF WORK ARE STAIRWAYS ST-2 AND ST-3

EXIT A:

DOOR ST-3: 36" WIDE, 180 CAPACITY

STAIRWAY ST-3: 3'-4" WIDE, 133 CAPACITY

EXIT B:

STAIRWAY ST-2: 3'-8" WIDE, 146 CAPACITY (NFPA 101 TABLE 7.3.3.1)

COMMON PATH OF TRAVEL FROM POINT A: 24' - 0"

COMMON PATH OF TRAVEL FROM POINT B: 95' - 0"

MAXIMUM COMMON PATH OF TRAVEL: 100 FT (NFPA 101 21.2.5..3.1)

1. AREA OF WORK IS FULLY SPRINKLERED PER NFPA 13. SEE FIRE PROTECTION SHEET

FP001 FOR MORE INFORMATION.

2. AREA OF WORK IS FULLY ALARMED PER NFPA 72. SEE FIRE PROTECTION SHEET FP001

FOR MORE INFORMATION AND EF1-1 FOR ALARM LOCATIONS.

3. ALL INFORMATION RELATING TO FIRE RATED CONSTRUCTION, AND EXITING WERE BASED

ON EXISTING DRAWINGS PROVIDED BY DEPARTMENT OF VETERAN AFFAIRS. THE

ARCHITECT WILL NOT BE RESPONSIBLE FOR ACCURACY OR FOR INTERPRETATION OF

INFORMATION ON PREVIOUS DRAWINGS.

4. SEE SHEET ES2-1, ES-2, AND ES2-3 FOR EXIT SIGN LOCATIONS.

CODE NOTES

STAIR 1

N

KEY PLAN

Floor 2

5 6 7

N

P

Q

R

S

T

U

V

1A

(E)

DUMBWAITER

R.2

177 SF

B130

(E) LAB

137 SF

(E) VESTIBULE

44 SF

B193

(E) TOILET

114 SF

B132

(E) EXAM

ROOM

115 SF

B133

(E) EXAM

ROOM

126 SF

B146

(E) EXAM

ROOM

116 SF

B145

(E) EXAM

ROOM

129 SF

B143B

(E) OFFICE

229 SF

B143A

(E) KITCHEN

102 SF

(E) VACANT

1139 SF

(E) VACANT

113 SF

(E) OFFICE

47 SF

(E) HAC

87 SF

(E) ANTE

ROOM

VESTIBULE

51 SF

(E) AIRLOCK

62 SF

Room

50 SF

Room

105 SF

Room

PHASE 2

2 2 4 6 8 10

1/4" = 1'-0"

FEETSCALE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

ARCHITECT OF RECORD

B

IM

/M a rt in e z B

/6

-1

-3

A

.r v t

/3

/2

:5 :3

P

M

GI005

FIRST FLOOR PHASING PLAN

CONCOURSE FEDERAL GROUP

213 SOUTH ROYAL STREET

ALEXANDRIA, VA 22314

GENE KLOW

REMODEL SPECIALTY

CARE - BUILDING 19

VA MARTINEZ

612-18-329

03/26/2021

100% - BID SET

1/4" = 1'-0"

FIRST FLOOR PHASE 2 PLAN

N

KEY PLAN

Floor 1

CONSTRUCTION

FIRE BARRIER

2 3 4 5

P

Q

R

S

T

U

V

167 SF

B226

(E) OCT /

PHOTOGRAPHY

ANGIOGRAPHY

/ STORAGE

162 SF

B225

(E) EXAM

159 SF

B224

(E) EXAM

125 SF

B227

(E) TECH

WORK AREA

682 SF

B216

(E)

RECEPTION

Redundant Room

CORRIDOR

141 SF

B223

(E)

OFFICE/EXAM

113 SF

B205

(E) LASER

336 SF

B214C

(E)

TREATMENT

111 SF

B214D

(E) EXAM

103 SF

B214A

(E) OFFICE

124 SF

B214E

(E) EXAM

104 SF

B214G

(E) EXAM

51 SF

B214I

(E) STORAGE

129 SF

B214J

(E) EXAM

126 SF

B214K

(E) EXAM

132 SF

B214L

(E) EXAM

100 SF

B214M

(E) EXAM

106 SF

B214H

(E) EXAM

109 SF

B214F

(E) EXAM

96 SF

B214N

(E) EXAM

81 SF

B214O

(E) TOILET

165 SF

B214P

(E) EXAM

586 SF

(E) CORRIDOR

50 SF

B214B

(E) TOILET

120 SF

B210

(E) EXAM

254 SF

B209

(E) CONF

145 SF

B208

(E) EXAM

113 SF

B214A

(E) OFFICE

160 SF

B207

(E) OFFICE

161 SF

B206

(E) OFFICE

90 SF

B202

(E) OFFICE

446 SF

(E) CORRIDOR

48 SF

B214Q

(E) CONTROL

ROOM

46 SF

B214R

(E) EXAM

48 SF

B214T

(E) CONTROL

ROOM

46 SF

B214V

(E) EXAM

105 SF

B214

(E) SOUND

ROOM

91 SF

B203

(E) SOUND

ROOM

Redundant Room

(E) CORRIDOR

PHASE 1 PHASE 2

R.2

E

F

G

88 SF

C201

OFFICE

144 SF

C204

CORRIDOR

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

ARCHITECT OF RECORD

B

IM

/M a rt in e z B

/6

-1

-3

A

.r v t

/3

/2

:5 :3

P

M

GI006

SECOND FLOOR PHASING PLAN

CONCOURSE FEDERAL GROUP

213 SOUTH ROYAL STREET

ALEXANDRIA, VA 22314

GENE KLOW

REMODEL SPECIALTY

CARE - BUILDING 19

VA MARTINEZ

612-18-329

03/26/2021

100% - BID SET

1/4" = 1'-0"

SECOND FLOOR PHASE 1 AND PHASE 2 PLAN

1/4" = 1'-0"

SECOND FLOOR NORTH PHASE 1 PLAN

N

KEY PLAN

Floor 2

2 2 4 6 8 10

1/4" = 1'-0"

FEETSCALE

CONSTRUCTION

FIRE BARRIER

M A

X

C L R

COAT HOOK (OFCI)

CL

O

P E

R A

T

IN

G

D E

V

IC

E F

O R

A

C C

E S

S

IB

L E

U N

IT

SURFACE

MOUNTED SOAP

DISPENSER

(OFCI)

O

P E

R A

T

IN

G

D

V

IC

E

6"

M A

X

MOTION SENSOR

PAPER TOWEL

DISPENSER (OFCI)

LIGHT SWITCH

WALL MOUNTED

ACCESSIBLE RESTROOM

SIGN

DOOR MOUNTED

ACCESSIBLE

RESTROOM SIGN

DOOR/EXIT

LIGHT W.O.

EQ EQ

2"

4"

2"

THERMOSTAT

FINISH FLOOR

GRAB BAR

LAVATORY -

WITH ADA

COMPLIANT PIPE

PROTECTOR

MIN.

1' - 4"

NURSE CALL

WITH PULL CORD

MIRROR

CL

IN

F

U S

IO

N

C H

A

IR

A T

C O

U N

T E

R

F O

R A

B O

V

M

IN

ACCESSIBLE

TOILET

TOILET PAPER

DISPENSER (OFCI)

2" 2"

T Y

P

ELEC. RECEPTACLE/ DATA OUTLET /

TELEPHONE OUTLET/ JUNCTION BOX

DATA OUTLET

MED. GASES OUTLET

NURSE CALL

O P

E R

A T

IN

G

D E

V I C

E

A T

FIRE ALARM MANUAL

PULL STATION

FIRE ALARM STROBE

LIGHT / HORN

H

A N

D L E

F.E.C.

CL

CL

"2"

4"

1' - 2"

8"

TOILET SEAT COVER

DISPENSER (OFCI)

MIN

1' - 4"

M A

X

ACCESSIBLE

URINAL

1' - 1"

NOTE:

THE 30" X 48" WHEELCHAIR CLEAR FLOOR SPACE IS

LOCATED A MAX 10" FROM THE WALL

NOTE:

IF THE DEPTH OF THE OBSTRUCTION IS 24" AND

THE MAXIMUM HEIGHT OF THE OBSTRUCTION IN

34", THE MAXIMUM HIGH SIDE REACH OVER THE

OBSTRUCTION IS 46".

NOTE:

THE 30" X 48" WHEELCHAIR CLEAR FLOOR SPACE IS

LOCATED A MAX 10" FROM THE WALL

NOTE:

X SHALL BE ≤ 25"; Z SHALL BE > X, WHEN X < 20", THEN Y SHALL BE 48" MAXIMUM.

WHEN X IS 20-25", THEN Y SHALL BE 44" MAXIMUM.

THE MAXIMUM LEVEL FORWARD REACH OVER AN OBSTRUCTION WITH KNEE SPACE BELOW IS 25".

WHEN THE OBSTRUCTION IS LESS THAN 20" DEEP, THE MAXIMUM HIGH FORWARD REACH IS 48".

WHEN THE OBSTRUCTION PROJECTS 20-25", THE MAXIMUM HIGH FORWARD REACH IS 44".

Z

X =

Y

Z

X

Y

10" MAX30"

FACE OF SWITCH OR

RECEPTACLE COVER PLATE

FACE OF SWITCH OR

RECEPTACLE COVER PLATE

30" 10" MAX

FACE OF SWITCH OR

RECEPTACLE COVER PLATE

30" > 10-24" MAX

FACE OF SWITCH OR

RECEPTACLE COVER PLATE

FACE OF SWITCH OR

RECEPTACLE COVER PLATE

48" 48"

16" MIN

30" MIN.

M

IN

16"−18"

SIZE OF CLEARANCE AT WATER

CLOSET PER PG 18-13 VA BARRIER

FREE DESIGN STANDARD

SIZE OF CLEARANCE

AT SINK PER 305;

ALSO REFERENCE 306

16" MIN

30" MIN.

M

IN

SIZE OF CLEARANCE

AT URINAL PER 305

M

IN

72" MIN.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

ARCHITECT OF RECORD

B

IM

/M a rt in e z B

/6

-1

-3

A

.r v t

/3

/2

:5 :4

P

M

GI100

ADA CLEARANCES AND TYPICAL

MOUNTING HEIGHTS

CONCOURSE FEDERAL GROUP

213 SOUTH ROYAL STREET

ALEXANDRIA, VA 22314

GENE KLOW

REMODEL SPECIALTY

CARE - BUILDING 19

VA MARTINEZ

612-18-329

03/26/2021

100% - BID SET

1/2" = 1'-0"

TYPICAL MOUNTING HEIGHT

3/8" = 1'-0"

MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS

3/8" = 1'-0"

MAXIMUM REACH HEIGHTS

3/8" = 1'-0"

MANUEVERING CLEARANCE APPROACHES

3/8" = 1'-0"

CLEARANCE AT PLUMBING FIXTURES

P

Q

R

S

T

U

V

1A

(E)

DUMBWAITER

B144

HAC

B130

LAB

B132

EXAM ROOM

B133

EXAM ROOM

B146

EXAM ROOM

B145

EXAM ROOM

B143B

OFFICE

B143A

STAFF

BREAKROOM

VACANT

B143F

HALLWAY

VACANT

B143E

OFFICE

B143D

(E)

RECEPTION

B193

TOILET

(E)

PRESCRIPTION

RECEIVING

(E)

PRESCRIPTION

RECEIVING

(E) OFFICE

(E) OFFICE,

SUPERVISORY

PHARMACIST

(E)

DISPENSING

B287

(E) ANTE

ROOM

VESTIBULE

B387

(E) AIRLOCK

B388

(E) CHEMO

HOOD ROOM

B389

(E) IV BUFFER

B390

(E) ANTE

ROOM

(E)

RECEPTION

/A 114 SF

EXAM

/A 115 SF

OFFICE

/A 97 SF

EXAM

137 SF

EXAM

/A 120 SF

B147

EXAM

(E) STORAGE,

CONTROLLED

SUBSTANCES,

SECURED

DISPENSING

REMOVE EXISTING PLUMBING FIXTURES;

ALSO SEE PLUMBING DWGS

REMOVE EXISTING PLUMBING

FIXTURE; ALSO SEE PLUMBING DWGS

REMOVE EXISTING WALL,

SHOWN DASHED; TYP

REMOVE EXISTING WALL,

SHOWN DASHED; TYP

REMOVE EXISTING DOORS,

FRAMES AND HARDWARE

REMOVE PORTION

OF EXISTING WALL

AS SHOWN

REMOVE PASS-THRU;

TYP. OF SIX (6) AND

MILLWORK ABOVE.

REMOVE EXISTING DOOR,

FRAME AND HARDWARE

REMOVE

EXISTING

WALL

REMOVE EXISTING WALL,

SHOWN DASHED; TYP

REMOVE EXISTING DOOR,

FRAME AND HARDWARE

REMOVE EXISTING DOOR,

FRAME AND HARDWARE

REMOVE EXISTING

WALL

REMOVE EXISTING DOORS,

FRAME AND HARDWARE

REMOVE EXISTING MILLWORK,

TYP OF FOUR (4)

REMOVE EXISTING

MILLWORK

REMOVE EXISTING PASS-THRU,

PREPARE WALL FOR NEW PASS-

THRU; GC TO COORDINATE

REMOVE EXISTING GLAZING

AND HARDWARE

REMOVE

EXISTING BARN

DOOR, FRAME

AND HARDWARE

REMOVE EXISTING GRAB BARS

REMOVE EXISTING MILLWORK

AND PLUMBING FIXTURE;

ALSO SEE PLUMBING DWGS

REMOVE EXISTING WALLS,

TYP OF THREE (3)

REMOVE EXISTING

TILE FROM FLOOR

EXISTING DUMBWAITER TO REMAIN; SEE ELECTRICAL

DWGS FOR RELOCATION OF CONTROLS

REMOVE EXISTING MILLWORK

(UPPER & LOWER CABINETS)

AND PLUMBING FIXTURE;

ALSO SEE PLUMBING DWGS

REMOVE EXISTING

TEMPORARY WALL

REMOVE EXISTING TILE FLOOR

AND WAINSCOT

REMOVE EXISTING MONITOR /

DISPLAY AND RETURN TO OWNER

REMOVE EXISTING

WOOD SHELF

REMOVE EXISTING OVERHEAD

COILING DOOR AND ALL HARDWARE

REMOVE EXISTING WALLS

REMOVE EXISTING MILLWORK

CAREFULLY REMOVE EXISTING

GYP BD TO INVESTIGATE IF CHASES

HAVE BUILDING SYSTEMS WITHIN. IF

SO CONTACT ARCH. REP. ON SITE.

IF NOT REMOVE EXISTING WALLS.

REMOVE EXISTING WALL

AND BULKHEAD

REMOVE EXISTING PLUMBING FIXTURE;

ALSO SEE PLUMBING DWGS

REMOVE EXISTING MILLWORK,

REMOVE EXISTING MILLWORK

AND PLUMBING FIXTURE;

ALSO SEE PLUMBING DWGS

REMOVE EXISTING

MILLWORK

REMOVE EXISTING

MILLWORK

REMOVE EXISTING MILLWORK

(UPPER & LOWER CABINETS)

AND PLUMBING FIXTURE;

ALSO SEE PLUMBING DWGS

REMOVE EXISTING MILLWORK

(UPPER & LOWER CABINETS)

AND PLUMBING FIXTURE;

ALSO SEE PLUMBING DWGS

REMOVE EXISTING

WOOD SHELFS

REMOVE EXISTING MILLWORK

REMOVE EXISTING DOOR,

FRAME AND HARDWARE

REMOVE EXISTING

DOOR, FRAME AND

HARDWARE; TYP

REMOVE EXISTING DOOR,

FRAME AND HARDWARE; TYP

REMOVE EXISTING

DOOR , FRAME,

SIDELIGHT AND

HARDWARE.

REMOVE EXISTING DOOR,

FRAME AND HARDWARE;TYP

REMOVE EXISTING WALL,

SHOWN DASHED; TYP

REMOVE EXISTING WALL,

SHOWN DASHED; TYP

REMOVE EXISTING WALL,

SHOWN DASHED; TYP

REMOVE EXISTING

RECESSED FIRE

EXTINGUISHER

CABINET

EXISTING WALL AND ACOUSTICAL

SEPARATION TO REMAIN

EXISTING STRUCTURAL

BRACE FURRING TO REMAIN

REMOVE EXISTING

WALL

R.2

EXISTING DOOR TO REMAIN

CONSTUCT TEMPORARY CONSTRUCTION BARRIER;

TO BE REMOVED AFTER CONSTRUCTION

CONSTRUCT TEMPORARY

CONSTRUCTION BARRIER;

TO BE REMOVED AFTER CONSTRUCTION

REMOVE EXISTING DOOR,

FRAME AND HARDWARE; TYP

EXISTING BLOOD DRAW

KIOSK. GC TO COORDINATE

TEMPORARY LOCATION

DURING CONSTRUCTION. SEE

ELEC DRAWINGS AND AI101

FOR FINAL LOCATION

EXISTING PHARMACY KIOSK. GC TO

RELOCATE DURING CONSTRUCTION. WORK

WITH TO COORDINATE FINAL LOCATION.

FOR WORK IN THIS AREA,

REF: DRAWING AD111

EXISTING WALL / PARTITION /

FURRING TO REMAIN

EXISTING WALL OR PARTITION TO BE

REMOVED

LEGEND

AREA NOT IN SCOPE OF WORK

EXISTING DOOR, FRAME AND

HARDWARE TO BE REMOVED

EXISTING DOOR, FRAME AND

HARDWARE TO REMAIN

EXISTING WINDOW, HARDWARE

AND/OR WINDOW TREATMENT

TO BE REMOVED

CONSTRUCTION BARRIER,

TO BE REMOVED

AFTER CONSTRUCTION

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

ARCHITECT OF RECORD

B

IM

/M a rt in e z B

/6

-1

-3

A

.r v t

/3

/2

:4 :1

P

M

AD101

ENLARGED PHASE 2 FIRST FLOOR

DEMOLITION PLAN - EAST

CONCOURSE FEDERAL GROUP

213 SOUTH ROYAL STREET

ALEXANDRIA, VA 22314

GENE KLOW

REMODEL SPECIALTY

CARE - BUILDING 19

VA MARTINEZ

612-18-329

03/26/2021

100% - BID SET

1/4" = 1'-0"

ENLARGED PHASE 2 FIRST FLOOR DEMOLITION PLAN - EAST

N

2 2 4 6 8 10

1/4" = 1'-0"

FEETSCALE

KEY PLAN

Floor 1

1. THIS DRAWING IS ONLY TO ASSIST IN SHOWING THE SCOPE OF DEMOLITION WORK AND IS NOT INTENDED TO INDICATE ALL DEMOLITION. CONTRACTOR SHALL REMOVE ALL EXISTING ITEMS AS REQUIRED TO COMPLETE THE JOB.

2. CONTRACTOR TO PROVIDE TEMPORARY BARRIER AROUND ALL AREAS OF WORK THAT SHALL PROTECT THE

FUNCTIONING SURROUNDING AREAS FREE OF DUST.

3. CONSTRUCTION BARRIER, DOORS AND OTHER MATERIAL TO BE REMOVED AFTER CONSTRUCTION HAS BEEN

COMPLETED AND SIGNED OFF.

4. REFER TO MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR EXTENT OF DEMOLITION TO THOSE SYSTEMS.

5. PROTECT ALL EXISTING STRUCTURE, SYSTEMS AND GENERAL CONSTRUCTION THAT ARE TO REMAIN THROUGHOUT

THE COURSE OF THE WORK TO PREVENT DAMAGE OR LOSS.

6. PROVIDE STRICT CONTROL OF JOB CLEANING AND PREVENT DUST AND DEBRIS FROM EMANATING FROM

DEMOLITION / CONSTRUCTION AREA. PROVIDE TEMPORARY PARTITIONS / BARRIERS AS REQUIRED.

7. DEMOLITION IS TO BE DONE IN A CAREFUL AND ORDERLY MANNER SO AS NOT TO DAMAGE FINISHES OR EQUIPMENT

TO REMAIN.

8. ALL WORK WILL BE PERFORMED IN THE BEST WORKMANSHIP POSSIBLE IN ACCORDANCE WITH THAT TRADE'S BEST

INDUSTRY STANDARDS.

9. WASTE MATERIAL AND RUBBISH FROM THE DEMOLITION OPERATION SHALL BE REMOVED FROM SITE AS RAPIDLY AS

POSSIBLE AND SHALL NOT BE ALLOWED TO ACCUMULATE ON PREMISES.

10. CONTRACTOR SHALL CHECK AND VERIFY ALL NOTES AND DIMENSIONS BEFORE PROCEEDING WITH WORK.

11. DO NOT SCALE DRAWINGS TO OBTAIN DIMENSIONS. USE WRITTEN DIMENSIONS ONLY AND VERIFY IN FIELD.

12. CONTRACTOR SHALL EXERCISE EXTREME CARE WHEN REMOVING EXISTING ITEMS THAT ARE SCHEDULED TO BE

RELOCATED AND/OR REUSED. PROTECT AND STORE THESE ITEMS ON SITE.

13. PATCH AND REPAIR EXISTING CONCRETE SLAB REMOVED OR DAMAGED BY NEW CONSTRUCTION WORK WITHIN OR

OUTSIDE THE PROJECT AREA. PATCH WORK SHALL MATCH EXISTING ADJACENT IN CONSTRUCTION, MATERIALS, BELOW SLAB VAPOR BARRIER, AGGREGATE BASE, SUB-BASE, COLORS, AND FINISHES.

14. EXISTING CONCRETE FLOOR SLABS AND / OR SURFACES SHALL BE PREPARED SO AS TO REMOVE ALL GREASE, BLUE, ETC., FILL ALL EXISTING CRACKS, DEPRESSIONS, AND INSTALL LEVELING COMPOUND TO PROVIDE A CLEAN AND

SMOOTH SUB-FLOOR FOR FINISHED FLOORING.

15. PATCH ALL FINISHES TO MATCH EXISTING, INCLUDING BUT NOT LIMITED, GYPSUM BOARD, PLASTER ACOUSTIC SYSTEMS, WOOD TRIM, COVERS, BASE AND RAILS. VERIFY MATCH OF NEW FINISHES TO EXISTING IN COLOR

TEXTURE, THICKNESS, CUT, ETC...TO SATISFACTION OF OWNER PRIOR TO INSTALLATIONS

GENERAL DEMOLITION NOTES

DEMOLITION NOTES

1. REMOVE ALL EXISTING SURFACE MOUNTED MIRRORS, PAPER TOWEL DISPENSERS, SOAP / LOTION DISPENSERS, TOILET PAPER HOLDERS AND SANITRY TOILET SEAT DISPENSERS.

2. REMOVE ALL EXISTING RECESSED PAPER TOWEL DISPENSERS AND TRASH RECEPTACLE

3. REMOVE ALL EXISTING WINDOW TREATMENTS AND HARDWARE

4. EXPANSION OF ROUGH OPENINGS FOR 42" DOORS AT EXAM ROOMS B132 AND B133 TO BE COORDINATED WITH THE

COR TO MINIMIZE DOWNTIME TO THOSE CLINICAL SPACES.

P

Q

R

S

T

U

V

B214B

TOILET

B214A

TREATMENT

B214C

OFFICE

B214D

EXAM

B214E

EXAM

B214F

EXAM

B214P

OFFICE

B214O

TOILET

B214N

LACTATION

B214M

EXAM

B214H

EXAM

B214G

EXAM

B214I

STORAGE

B214J

EXAM

B214K

EXAM

/A 120 SF

B210

AUDIOLOGY

TECHS

/A 254 SF

B209

CONF

/A 145 SF

B208

SUPPLY LAB

B214L

EXAM

/A 113 SF

B214A

OFFICE

/A 160 SF

B207

OFFICE

/A 161 SF

B206

OFFICE

/A Not Enclosed

B216A

RECEPTION

/A 90 SF

B202

AUDIOLOGY

ADMIN ASST

/A 91 SF

B203

AUDIOLOGY

LAB 1

/A 48 SF

B214Q

CONTROL

/A 46 SF

B214R

AUDIO BOOTH

/A 48 SF

B214T

CONTROL

/A 46 SF

B214V

AUDIO BOOTH

/A 105 SF

B204

AUDIOLOGY

LAB 2

/A 226 SF

B216

(E)

RECEPTION

/A 125 SF

B227

TECH WORK

/A 167 SF

B226

(E) OCT/

PHOTO/ ANGIO

/A 162 SF

B225

(E) EXAM

/A 159 SF

B224

(E) EXAM

B205

(E) OFFICE B223

(E) OFFICE /

EXAM

/A 70 SF

B392

(E) HUDDLE

(E)

CIRCULATION

LEAVE EXISTING COLUMN AND

BRACING FURRING WALLS.

LEAVE EXISTING COLUMN AND

BRACING FURRING WALLS.

LEAVE BRACING

FURRING.

LEAVE BRACING FURRING.

LEAVE EXISTING COLUMN AND

BRACING FURRING WALLS.

REMOVE EXISTING PLUMBING FIXTURES;

ALSO SEE PLUMBING DWGS

REMOVE EXISTING PLUMBING FIXTURES;

ALSO SEE PLUMBING DWGS

REMOVE EXISTING MILLWORK

(UPPER & LOWER CABINETS)

REMOVE EXISTING MILLWORK

AND PLUMBING FIXTURE;

ALSO SEE PLUMBING DWGS

REMOVE EXISTING MILLWORK

(UPPER & LOWER CABINETS)

AND PLUMBING FIXTURE;

ALSO SEE PLUMBING DWGS

REMOVE EXISTING MILLWORK

(UPPER & LOWER CABINETS)

AND PLUMBING FIXTURE;

ALSO SEE PLUMBING DWGS

REMOVE EXISTING MILLWORK

(UPPER & LOWER CABINETS)

AND PLUMBING FIXTURE;

ALSO SEE PLUMBING DWGS

REMOVE EXISTING MILLWORK

(UPPER & LOWER CABINETS)

AND PLUMBING FIXTURE;

ALSO SEE PLUMBING DWGS

REMOVE EXISTING WALL MOUNTED

DISPLAY SCREEN, IF PRESENT AND

RETURN TO OWNER

REMOVE EXISTING MILLWORK

(UPPER & LOWER CABINETS)

AND PLUMBING FIXTURE;

ALSO SEE PLUMBING DWGS

REMOVE EXISTING MILLWORK

(UPPER & LOWER CABINETS)

AND PLUMBING FIXTURE;

ALSO SEE PLUMBING DWGS

REMOVE EXISTING MILLWORK

(UPPER & LOWER CABINETS)

AND PLUMBING FIXTURE;

ALSO SEE PLUMBING DWGS

REMOVE EXISTING MILLWORK

(UPPER & LOWER CABINETS)

AND PLUMBING FIXTURE;

ALSO SEE PLUMBING DWGS

REMOVE EXISTING MILLWORK

(UPPER & LOWER CABINETS)

AND PLUMBING FIXTURE;

ALSO SEE PLUMBING DWGS

REMOVE EXISTING GRAB BARS

REMOVE EXISTING MILLWORK

REMOVE PORTION OF EXISTING

WALL, PREPARE FRAMING TO

RECEIVE NEW GWB; REF. 1/AE103

REMOVE

EXISTING

WALLS

REMOVE EXISTING DOOR,

FRAME AND HARDWARE

REMOVE EXISTING DOOR,

FRAME AND HARDWARE

REMOVE EXISTING

RECESSED FIRE

EXTINGUISHER CABINET

REMOVE EXISTING DOOR,

FRAME AND HARDWARE

REMOVE EXISTING WALL

REMOVE EXISTING WALL,

SHOWN DASHED; TYP

REMOVE EXISTING

WINDOW

REMOVE EXISTING

MILLWORK

REMOVE EXISTING DOOR,

FRAME AND HARDWARE;

SHOWN DASHED, TYP

REMOVE EXISTING GRAB BARS

PHASE 1 DEMOLITION PHASE 2 DEMOLITION

PHASE 2 DEMOLITION

/A 238 SF

CORRIDOR

/A 208 SF

CORRIDOR

REMOVE EXISTING WALL,

SHOWN DASHED; TYP

REMOVE EXISTING WALL,

SHOWN DASHED; TYP

REMOVE EXISTING TILE

FLOORING AND WAINSCOT

REMOVE EXISTING DOOR,

FRAME AND HARDWARE;

SHOWN DASHED, TYP

REMOVE EXISTING DOOR,

FRAME AND HARDWARE;

SHOWN DASHED, TYP

REMOVE EXISTING WALL,

SHOWN DASHED; TYP

REMOVE EXISTING DOOR,

FRAME AND HARDWARE;

SHOWN DASHED, TYP

REMOVE EXISTING WALL,

SHOWN DASHED; TYP

REMOVE EXISTING DOOR,

FRAME AND HARDWARE

REMOVE EXISTING MILLWORK

(UPPER & LOWER CABINETS)

AND PLUMBING FIXTURE;

ALSO SEE PLUMBING DWGS

REMOVE EXISTING MILLWORK

(UPPER & LOWER CABINETS)

AND PLUMBING FIXTURE;

ALSO SEE PLUMBING DWGS

REMOVE EXISTING

FRAMING AROUND COLUMN

REMOVE EXISTING

FRAMING AROUND COLUMN

R.2

CONSTRUCT TEMPORARY CONSTRUCTION BARRIER;

TO BE REMOVED AFTER CONSTRUCTION

BEFORE COMMENCING PHASE ONE

DEMOLITION, INSTALL TEMPORARY

SIGNAGE WARNING OF CONSTRUCTION

AREA ON FACE OF DOOR

PROVIDE POLY ATTACHED TO THE

STRUCTURE ABOVE AND AFFIXED

TO THE FACE OF THE (E) WALL

(MIN. 2'-0" BELOW T.O.W.) ENTIRE PERIMETER;

TO CONTROL DUST FROM MIGRATING INTO

ADJOINING OCCUPIED SPACES.

PROVIDE POLY ATTACHED TO THE

STRUCTURE ABOVE AND AFFIXED

TO THE FACE OF THE (E) WALL

(MIN. 2'-0" BELOW T.O.W.) ENTIRE PERIMETER;

TO CONTROL DUST FROM MIGRATING INTO

ADJOINING OCCUPIED SPACES.

E

F

G

REMOVE EXISTING DOOR

AND HARDWARE

C201

SURGERYOFFICE

REMOVE EXISTING

PARTITIONS

REMOVE EXISTING PARTITIONS

REMOVE EXISTING

MILLWORK

REMOVE EXISTING LOCKERS

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

ARCHITECT OF RECORD

B

IM

/M a rt in e z B

/6

-1

-3

A

.r v t

/3

/2

:4 :1

P

M

AD102

ENLARGED PHASE 1 SECOND

FLOOR DEMOLITION PLANS

CONCOURSE FEDERAL GROUP

213 SOUTH ROYAL STREET

ALEXANDRIA, VA 22314

GENE KLOW

REMODEL SPECIALTY

CARE - BUILDING 19

VA MARTINEZ

612-18-329

03/26/2021

100% - BID SET

1/4" = 1'-0"

ENLARGED PHASE 1 SECOND FLOOR DEMOLITION PLAN

1/4" = 1'-0"

ENLARGED PHASE 1 SECOND FLOOR

DEMOLITION PLAN - NORTH

N

KEY PLAN

Floor 2

2 2 4 6 8 10

1/4" = 1'-0"

FEETSCALE

1. THIS DRAWING IS ONLY TO ASSIST IN SHOWING THE SCOPE OF DEMOLITION WORK AND IS NOT INTENDED TO INDICATE ALL DEMOLITION. CONTRACTOR SHALL REMOVE ALL EXISTING ITEMS AS REQUIRED TO COMPLETE THE JOB.

2. CONTRACTOR TO PROVIDE TEMPORARY BARRIER AROUND ALL AREAS OF WORK THAT SHALL PROTECT THE

FUNCTIONING SURROUNDING AREAS FREE OF DUST.

3. CONSTRUCTION BARRIER, DOORS AND OTHER MATERIAL TO BE REMOVED AFTER CONSTRUCTION HAS BEEN

COMPLETED AND SIGNED OFF.

4. REFER TO MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR EXTENT OF DEMOLITION TO THOSE SYSTEMS.

5. PROTECT ALL EXISTING STRUCTURE, SYSTEMS AND GENERAL CONSTRUCTION THAT ARE TO REMAIN THROUGHOUT

THE COURSE OF THE WORK TO PREVENT DAMAGE OR LOSS.

6. PROVIDE STRICT CONTROL OF JOB CLEANING AND PREVENT DUST AND DEBRIS FROM EMANATING FROM

DEMOLITION / CONSTRUCTION AREA. PROVIDE TEMPORARY PARTITIONS / BARRIERS AS REQUIRED.

7. DEMOLITION IS TO BE DONE IN A CAREFUL AND ORDERLY MANNER SO AS NOT TO DAMAGE FINISHES OR EQUIPMENT

TO REMAIN.

8. ALL WORK WILL BE PERFORMED IN THE BEST WORKMANSHIP POSSIBLE IN ACCORDANCE WITH THAT TRADE'S BEST

INDUSTRY STANDARDS.

9. WASTE MATERIAL AND RUBBISH FROM THE DEMOLITION OPERATION SHALL BE REMOVED FROM SITE AS RAPIDLY AS

POSSIBLE AND SHALL NOT BE ALLOWED TO ACCUMULATE ON PREMISES.

10. CONTRACTOR SHALL CHECK AND VERIFY ALL NOTES AND DIMENSIONS BEFORE PROCEEDING WITH WORK.

11. DO NOT SCALE DRAWINGS TO OBTAIN DIMENSIONS. USE WRITTEN DIMENSIONS ONLY AND VERIFY IN FIELD.

12. CONTRACTOR SHALL EXERCISE EXTREME CARE WHEN REMOVING EXISTING ITEMS THAT ARE SCHEDULED TO BE

RELOCATED AND/OR REUSED. PROTECT AND STORE THESE ITEMS ON SITE.

13. PATCH AND REPAIR EXISTING CONCRETE SLAB REMOVED OR DAMAGED BY NEW CONSTRUCTION WORK WITHIN OR

OUTSIDE THE PROJECT AREA. PATCH WORK SHALL MATCH EXISTING ADJACENT IN CONSTRUCTION, MATERIALS, BELOW SLAB VAPOR BARRIER, AGGREGATE BASE, SUB-BASE, COLORS, AND FINISHES.

14. EXISTING CONCRETE FLOOR SLABS AND / OR SURFACES SHALL BE PREPARED SO AS TO REMOVE ALL GREASE, BLUE, ETC., FILL ALL EXISTING CRACKS, DEPRESSIONS, AND INSTALL LEVELING COMPOUND TO PROVIDE A CLEAN AND

SMOOTH SUB-FLOOR FOR FINISHED FLOORING.

15. PATCH ALL FINISHES TO MATCH EXISTING, INCLUDING BUT NOT LIMITED, GYPSUM BOARD, PLASTER ACOUSTIC SYSTEMS, WOOD TRIM, COVERS, BASE AND RAILS. VERIFY MATCH OF NEW FINISHES TO EXISTING IN COLOR

TEXTURE, THICKNESS, CUT, ETC...TO SATISFACTION OF OWNER PRIOR TO INSTALLATIONS

GENERAL DEMOLITION NOTES

DEMOLITION NOTES

1. REMOVE ALL EXISTING SURFACE MOUNTED MIRRORS, PAPER TOWEL DISPENSERS, SOAP / LOTION DISPENSERS, TOILET PAPER HOLDERS AND SANITARY TOILET SEAT DISPENSERS.

2. REMOVE ALL EXISTING RECESSED PAPER TOWEL DISPENSERS AND TRASH RECEPTACLE

3. REMOVE ALL EXISTING WINDOW TREATMENT AND HARDWARE

4. ALL PHASE 1 WORK TO BE COMPLETED, OPERATIONAL AND APPROVED BY THE COR PRIOR TO ANY PHASE 2

DEMOLITION COMMENCING.

P

Q

R

S

T

U

V

/A 226 SF

B216

(E)

RECEPTION

/A 125 SF

B227

RN/ PA OFFICE

/A 167 SF

B226

PROCEDURE/

EXAM

/A 162 SF

B225

(E) EXAM 4

/A 159 SF

B224

(E) EXAM 3

/A 113 SF

B205

(E) EXAM/

TREATMENT 5

/A 141 SF

B223

(E) OFFICE /

EXAM

/A 386 SF

(E)

CIRCULATION

/A 417 SF

B349

WAITING /A 139 SF

B216A

RECEPTION -

EYE CLINIC

RCP1

/A 67 SF

B391

(E)

CIRCULATION

/A 70 SF

B392

(E) HUDDLE

REMOVE EXISTING PLUMBING FIXTURES;

ALSO SEE PLUMBING DWGS

REMOVE EXISTING PLUMBING FIXTURES;

ALSO SEE PLUMBING DWGS

REMOVE

EXISTING

WINDOW

REMOVE EXISTING PLUMBING FIXTURES;

ALSO SEE PLUMBING DWGS

CAREFULLY REMOVE EXISTING

ACOUSTICAL WALL FINISH

REMOVE EXISTING MILLWORK

(UPPER & LOWER CABINETS)

AND PLUMBING FIXTURE;

ALSO SEE PLUMBING DWGS

REMOVE EXISTING MILLWORK

(UPPER & LOWER CABINETS)

REMOVE EXISTING MILLWORK

REMOVE EXISTING

RECESSED FIRE

EXTINGUISHER CABINET

PHASE 1 COMPLETED

CONSTRUCTION

PHASE 2 DEMOLITION

AUDIOLOGY

TECHS

B210

A 120 SF /

CONF

B209

A 254 SF /

AUDIOLOGY

ADMIN ASST

B202

A 90 SF /

AUDIOLOGY

LAB 1

B203

A 91 SF /

SUPPLY LAB

B208

A 145 SF /

AUDIOLOGY

LAB 2

B204

A 105 SF /

CONTROL

B214T

A 48 SF /

CONTROL

B214Q

A 48 SF /

AUDIO BOOTH

B214R

A 46 SF /

AUDIO BOOTH

B214V

A 46 SF /

OFFICE

B214A

A 113 SF /

OFFICE

B207

A 160 SF /

OFFICE

B206

A 161 SF /

CORRIDOR

A 177 SF /

CORRIDOR

A 208 SF /

CAREFULLY REMOVE EXISTING

ACOUSTICAL WALL FINISH

REMOVE EXISTING WALL,

SHOWN DASHED; TYP

REMOVE ENTIRE AUDIO

BOOTH AND ALL IT'S

COMPONENTS

REMOVE ENTIRE AUDIO

BOOTH AND ALL IT'S

COMPONENTS

REMOVE EXISTING DOOR,

FRAME AND HARDWARE,

SHOWN DASHED; TYP

REMOVE EXISTING MILLWORK

(UPPER & LOWER CABINETS)

AND PLUMBING FIXTURE;

ALSO SEE PLUMBING DWGS

REMOVE EXISTING WALL,

SHOWN DASHED; TYP

REMOVE EXISTING DOOR,

FRAME AND HARDWARE,

SHOWN DASHED; TYP

REMOVE EXISTING WALL,

SHOWN DASHED; TYP

REMOVE EXISTING DOOR,

FRAME AND HARDWARE,

SHOWN DASHED; TYP

REMOVE EXISTING DOOR,

FRAME AND HARDWARE,

SHOWN DASHED; TYP

REMOVE EXISTING

WALL, SHOWN

DASHED; TYP

R.2

CONSTRUCT TEMPORARY

CONSTRUCTION BARRIER;

TO BE REMOVED

AFTER CONSTRUCTION

BEFORE COMMENCING PHASE TWO DEMOLITION,

INSTALL TEMPORARY SIGNAGE WARNING OF

CONSTRUCTION AREA ON FACE OF DOOR

PROVIDE POLY ATTACHED TO THE

STRUCTURE ABOVE AND AFFIXED

TO THE FACE OF THE (E) WALL

(MIN. 2'-0" BELOW T.O.W.) ENTIRE PERIMETER;

TO CONTROL DUST FROM MIGRATING INTO

ADJOINING OCCUPIED SPACES.

THE GENERAL CONTRACTOR SHALL

PROVIDE ADEQUATE PROTECTION

TO ENSURE THAT NO DAMAGE

OCCURS TO FINISHED MATERIALS

THAT WERE INSTALLED DURING

PHASE 1.

COVER ANY PENETRATIONS

IN NEW PARTITION TO

CONTROL DUST FROM

MIGRATING INTO

ADJOINING OCCUPIED SPACES

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

ARCHITECT OF RECORD

B

IM

/M a rt in e z B

/6

-1

-3

A

.r v t

/3

/2

:4 :2

P

M

AD103

ENLARGED PHASE 2 SECOND

FLOOR DEMOLITION PLAN

CONCOURSE FEDERAL GROUP

213 SOUTH ROYAL STREET

ALEXANDRIA, VA 22314

GENE KLOW

REMODEL SPECIALTY

CARE - BUILDING 19

VA MARTINEZ

612-18-329

03/26/2021

100% - BID SET

N

KEY PLAN

Floor 2

2 2 4 6 8 10

1/4" = 1'-0"

FEETSCALE

1/4" = 1'-0"

ENLARGED PHASE 2 SECOND FLOOR DEMOLITION PLAN

1. THIS DRAWING IS ONLY TO ASSIST IN SHOWING THE SCOPE OF DEMOLITION WORK AND IS NOT INTENDED TO INDICATE ALL DEMOLITION. CONTRACTOR SHALL REMOVE ALL EXISTING ITEMS AS REQUIRED TO COMPLETE THE JOB.

2. CONTRACTOR TO PROVIDE TEMPORARY BARRIER AROUND ALL AREAS OF WORK THAT SHALL PROTECT THE

FUNCTIONING SURROUNDING AREAS FREE OF DUST.

3. CONSTRUCTION BARRIER, DOORS AND OTHER MATERIAL TO BE REMOVED AFTER CONSTRUCTION HAS BEEN

COMPLETED AND SIGNED OFF.

4. REFER TO MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR EXTENT OF DEMOLITION TO THOSE SYSTEMS.

5. PROTECT ALL EXISTING STRUCTURE, SYSTEMS AND GENERAL CONSTRUCTION THAT ARE TO REMAIN THROUGHOUT

THE COURSE OF THE WORK TO PREVENT DAMAGE OR LOSS.

6. PROVIDE STRICT CONTROL OF JOB CLEANING AND PREVENT DUST AND DEBRIS FROM EMANATING FROM

DEMOLITION / CONSTRUCTION AREA. PROVIDE TEMPORARY PARTITIONS / BARRIERS AS REQUIRED.

7. DEMOLITION IS TO BE DONE IN A CAREFUL AND ORDERLY MANNER SO AS NOT TO DAMAGE FINISHES OR EQUIPMENT

TO REMAIN.

8. ALL WORK WILL BE PERFORMED IN THE BEST WORKMANSHIP POSSIBLE IN ACCORDANCE WITH THAT TRADE'S BEST

INDUSTRY STANDARDS.

9. WASTE MATERIAL AND RUBBISH FROM THE DEMOLITION OPERATION SHALL BE REMOVED FROM SITE AS RAPIDLY AS

POSSIBLE AND SHALL NOT BE ALLOWED TO ACCUMULATE ON PREMISES.

10. CONTRACTOR SHALL CHECK AND VERIFY ALL NOTES AND DIMENSIONS BEFORE PROCEEDING WITH WORK.

11. DO NOT SCALE DRAWINGS TO OBTAIN DIMENSIONS. USE WRITTEN DIMENSIONS ONLY AND VERIFY IN FIELD.

12. CONTRACTOR SHALL EXERCISE EXTREME CARE WHEN REMOVING EXISTING ITEMS THAT ARE SCHEDULED TO BE

RELOCATED AND/OR REUSED. PROTECT AND STORE THESE ITEMS ON SITE.

13. PATCH AND REPAIR EXISTING CONCRETE SLAB REMOVED OR DAMAGED BY NEW CONSTRUCTION WORK WITHIN OR

OUTSIDE THE PROJECT AREA. PATCH WORK SHALL MATCH EXISTING ADJACENT IN CONSTRUCTION, MATERIALS, BELOW SLAB VAPOR BARRIER, AGGREGATE BASE, SUB-BASE, COLORS, AND FINISHES.

14. EXISTING CONCRETE FLOOR SLABS AND / OR SURFACES SHALL BE PREPARED SO AS TO REMOVE ALL GREASE, BLUE, ETC., FILL ALL EXISTING CRACKS, DEPRESSIONS, AND INSTALL LEVELING COMPOUND TO PROVIDE A CLEAN AND

SMOOTH SUB-FLOOR FOR FINISHED FLOORING.

15. PATCH ALL FINISHES TO MATCH EXISTING, INCLUDING BUT NOT LIMITED, GYPSUM BOARD, PLASTER ACOUSTIC SYSTEMS, WOOD TRIM, COVERS, BASE AND RAILS. VERIFY MATCH OF NEW FINISHES TO EXISTING IN COLOR

TEXTURE, THICKNESS, CUT, ETC...TO SATISFACTION OF OWNER PRIOR TO INSTALLATIONS

GENERAL DEMOLITION NOTES

DEMOLITION NOTES

1. REMOVE ALL EXISTING SURFACE MOUNTED MIRRORS, PAPER TOWEL DISPENSERS, SOAP / LOTION DISPENSERS, TOILET PAPER HOLDERS AND SANITARY TOILET SEAT DISPENSERS.

2. REMOVE ALL EXISTING RECESSED PAPER TOWEL DISPENSERS AND TRASH RECEPTACLE

3. REMOVE ALL EXISTING WINDOW TREATMENT AND HARDWARE

4. EXPANSION OF ROUGH OPENINGS FOR 42" DOORS AT EXAM ROOMS B132 AND B133 TO BE COORDINATED WITH THE

COR TO MINIMIZE DOWNTIME TO THOSE CLINICAL SPACES.

5. ALL PHASE 1 WORK TO BE COMPLETED, OPERATIONAL AND APPROVED BY THE COR PRIOR TO ANY PHASE 2

DEMOLITION COMMENCING.

P

Q Q

R R

S

T

U

V V

1A

B144

HAC

B130

LAB

B132

EXAM ROOM

B133

EXAM ROOM

B146

EXAM ROOM

B145

EXAM ROOM

B143B

OFFICE

B143A

STAFF

BREAKROOM

VACANT

B143F

HALLWAY

VACANT

B143E

OFFICE

B143D

(E)

RECEPTION

B193

TOILET

/A 533 SF

(E)

PRESCRIPTION

RECEIVING

/A Redundant Room

(E)

PRESCRIPTION

RECEIVING

/A 121 SF

(E) OFFICE

/A 133 SF

(E) OFFICE,

SUPERVISORY

PHARMACIST

/A 172 SF

(E) STORAGE,

CONTROLLED

SUBSTANCES,

SECURED

DISPENSING

/A Not Enclosed

(E)

DISPENSING

/A 87 SF

B287

(E) ANTE

ROOM

VESTIBULE

/A 51 SF

B387

(E) AIRLOCK

/A 62 SF

B388

(E) CHEMO

HOOD ROOM

/A 50 SF

B389

(E) IV BUFFER

/A 105 SF

B390

(E) ANTE

ROOM

/A 151 SF

(E)

RECEPTI…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .