S02_Attachment-4_Drawings_847CM3020_Part3.pdf
PDF 11 MB Posted
- Solicitation number
- 36C78621B0019
About this file
This notice describes a federal contract opportunity for renovating a maintenance building at Fort Smith National Cemetery. The Department of Veterans Affairs, National Cemetery Administration intends to issue a solicitation for the project, with an estimated value between $500,000 and $1,000,000. The solicitation will be open only to verified Service-Disabled Veteran-Owned Small Businesses, with a NAICS code of 236220 and size standard of $36.5 million. Electronic copies of the solicitation will be available on SAM.gov starting August 10, 2021. Bids are due on the date specified in the solicitation. Interested parties must register on Vendor Information Pages and System for Award Management websites. The point of contact for questions is Jerry L. Hodson Jr. via email.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WH
AD-200 2
AD-201
1 1 1 1
AD-2011
AD-200
6 6
9 9 9 9
EQUIPMENT
STORAGE
MB103
LOCKER BREAK
MB107
RESTROOM
MB106
UNISEX TOILET
MB102
EQUIPMENT
STORAGE
MB101
SHOWER
MB108
GENERAL NOTES
A. VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE.
B. VERIFY EXACT COMPOSITION OF EXISTING WALLS TO BE REMOVED.
C. REMOVE ALL EXISTING WALL MOUNTED EQUIPMENT AND FIXTURES
AS NEEDED TO APPLY NEW FINISHES. REF. MEP DRAWINGS FOR
ADDITIONAL ITEMS AND NOTES. COORDINATE WITH NCA TO
CONFIRM SALVAGING AND DISPOSAL.
D. REFER TO MEP DRAWINGS FOR ADDITIONAL DEMOLITION ITEMS
AND NOTES. COORDINATE WORK WITH MEP REQUIREMENTS.
E. ALL EXISTING ABANDONED MEP EQUIPMENT AND ALL ASSOCIATED
PIPING AND CONDUIT DISCOVERED DURING DEMOLITION IS TO BE
REMOVED AND PROPERLY DISPOSED BY CONTRACTOR.
F. ALL EXISTING COLUMNS, BEAMS, LOAD BEARING WALLS AND
STRUCTURAL ASSEMBLIES TO REMAIN UNLESS NOTED OTHERWISE.
PROTECT DURING CONSTRUCTION.
DASHED LINE
DENOTES
ITEM TO BE
REMOVED
LINE DENOTES
ITEM TO
REMAIN
EXISTING WALLS
TO BE REMOVED
EXISTING WALLS
TO REMAIN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PROJECT ARCHITECT STAMPCONSULTANT
321 4 5 6 7 8 9 10
N/A
FORTH SMITH, AR
INTERIORSARCHITECTURE
COX DESIGN ASSOCIATES
PLANNING
Austin 5121 Bee Caves Road, Suite 203 Austin, Texas 78746 T: 512-327-4149 F: 512-327-7679e info@coxdesignassociates.com
BI
M
FO
R T
SM
IT
H N
AT
IO
N
AL
C
EM
ET
ER
Y/
FO
R T.
S M
IT
H
N
AT
IO
N
AL
C
EM
ET
ER
Y_
AR
C
H _0
1.
rv t
7/
/2
:0 1:
A
M
AD-100
MAINTENANCE BLDG. FLOOR
PLAN - DEMO
RENOVATE MAINTENANCE
FACILITY
07/15/2021 RHC MAG
847CM3020
SCALE: 1/4" = 1'-0"1 MAINTENANCE BLDG. FLOOR PLAN - DEMO
1 EXISTING WINDOW - REMOVE AND DISPOSE ENTIRE ASSEMBLY.
2 EXISTING DOOR AND FRAME - REMOVE AND DISPOSE OF ENTIRE
ASSEMBLY.
3 PER STATEMENT OF WORK CHANGE BY COR, EXISTING DOOR AND
FRAME ASSEMBLY TO BE REFURBISHED AND RE-PAINTED
INCLUDING ALL COMPONENTS AND ACCESSORIES FOR A FULLY
FUNCTIONAL DOOR.
4 EXISTING LIGHT FIXTURES, SUPPLY, RETURN AND EXHAUST
GRILLES TO BE REMOVED. PREPARE EXISTING CEILINGS FOR NEW
FIXTURES. REF. MEP DRAWINGS.
5 EXISTING EXTERIOR WALL TO REMAIN - EXISTING FINISHES AT
INTERIOR FACE OF PARTITION COMMON TO THE IDENTIFIED WORK
AREA ARE TO BE PATCHED, REPAIRED AND PREPARED FOR NEW
APPLIED FINISHES AS SCHEDULED.
6 EXISTING PARTITION TO REMAIN - EXISTING FINISHES AT FACE OF
PARTITION COMMON TO THE IDENTIFIED WORK AREA ARE TO BE
PATCHED, REPAIRED AND PREPARED FOR NEW APPLIED FINISHES
AS SCHEDULED.
7 EXISTING PLUMBING FIXTURE - REMOVE AND DISPOSE OF ENTIRE
ASSEMBLY. REF. MEP DRAWINGS.
8 REMOVE ALL EXISTING ELECTRICAL / DATA OUTLETS,
COVERPLATES, MEP ACCESS PANELS AND WALL MOUNTED MEP
FIXTURES IN PREPARATION FOR NEW WALL FINISHES. SALVAGE
AND STORE ITEMS FOR REINSTALLATION, COORDINATE WITH NCA.
REF. MEP DRAWINGS.
9 REMOVE EXISTING SPLASHBLOCK.
10 EXISTING CASEWORK ASSEMBLY TO BE REMOVED.
11 EXISTING CEILING ASSEMBLY - REMOVE AND DISPOSE OF ENTIRE
ASSEMBLY.
12 EXISTING BRICK COLUMN TO REMAIN, PROTECT DURING
CONSTRUCTION.
13 PREPARE EXISTING DOOR TO RECEIVE A NEW 12"X12" AIR GRILLE.
14 PREPARE EXISTING DOOR TO RECEIVE A NEW 12"X24" AIR GRILLE.
KEY NOTES
GRAPHIC LEGEND
BID Set
Revisions: Date:
AD-200 2
AD-201
AD-2011
AD-200
VI
F
/8
GENERAL NOTES
A. VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE.
B. VERIFY EXACT COMPOSITION OF EXISTING WALLS TO BE REMOVED.
C. REMOVE ALL EXISTING WALL MOUNTED EQUIPMENT AND FIXTURES
AS NEEDED TO APPLY NEW FINISHES. REF. MEP DRAWINGS FOR
ADDITIONAL ITEMS AND NOTES. COORDINATE WITH NCA TO
CONFIRM SALVAGING AND DISPOSAL.
D. REFER TO MEP DRAWINGS FOR ADDITIONAL DEMOLITION ITEMS
AND NOTES. COORDINATE WORK WITH MEP REQUIREMENTS.
E. ALL EXISTING ABANDONED MEP EQUIPMENT AND ALL ASSOCIATED
PIPING AND CONDUIT DISCOVERED DURING DEMOLITION IS TO BE
REMOVED AND PROPERLY DISPOSED BY CONTRACTOR.
F. ALL EXISTING COLUMNS, BEAMS, LOAD BEARING WALLS AND
STRUCTURAL ASSEMBLIES TO REMAIN UNLESS NOTED OTHERWISE.
PROTECT DURING CONSTRUCTION.
DASHED LINE
DENOTES
ITEM TO BE
REMOVED
LINE DENOTES
ITEM TO
REMAIN
EXISTING WALLS
TO BE REMOVED
EXISTING WALLS
TO REMAIN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PROJECT ARCHITECT STAMPCONSULTANT
321 4 5 6 7 8 9 10
N/A
FORTH SMITH, AR
INTERIORSARCHITECTURE
COX DESIGN ASSOCIATES
PLANNING
Austin 5121 Bee Caves Road, Suite 203 Austin, Texas 78746 T: 512-327-4149 F: 512-327-7679e info@coxdesignassociates.com
BI
M
FO
R T
SM
IT
H N
AT
IO
N
AL
C
EM
ET
ER
Y/
FO
R T.
S M
IT
H
N
AT
IO
N
AL
C
EM
ET
ER
Y_
AR
C
H _0
1.
rv t
7/
/2
:0 1:
A
M
AD-101
MAINTENANCE BLDG. ROOF
PLAN - DEMO
RENOVATE MAINTENANCE
FACILITY
07/15/2021 RHC MAG
847CM3020
SCALE: 1/4" = 1'-0"1 MAINTENANCE BLDG. ROOF PLAN - DEMO
1 EXISTING ROOFING MEMBRANE TO BE REPAIRED AROUND VICINITY
OF MECHANICAL EQUIPMENT. COORDINATE WITH INSTALLATION
OF NEW MECHANICAL EQUIPMENT ASSEMBLY.
2 EXISTING CONCRETE COPING AND ALUMINUM FLASHING TO BE
REMOVED, REPAIR (APPROXIMATELY 20% OF COPING,
CONTRACTOR TO VERIFY) AND CLEAN CONCRETE COPING AND
PREPARE EXISTING SURFACES FOR REINSTALLATION.
3 EXISTING MECHANICAL EQUIPMENT TO BE REMOVED, REF. MEP
DRAWINGS.
4 MECHANICAL EQUIPMENT, RE. MEP DRAWINGS.
5 EXISTING METAL PANEL ASSEMBLY TO BE REMOVED AND
PREPARED FOR NEW PAINT FINISH, PAINTED AND REINSTALLED
AFTER NEW FLASHING IS INSTALLED.
6 REMOVE DAMAGED PORTION OF THE EXISTING ROOF ASSEMBLY
AROUND VICINITY OF EXISTING MECHANICAL EQUIPMENT CURB.
PREPARE ROOF TO RECEIVE NEW MECHANICAL EQUIPMENT, REF.
MEP DRAWINGS. CONTRACTOR SHALL COORDINATE ROOF REPAIR
AND MECHANICAL EQUIPMENT INSTALLATION, BUILDING TO BE
WEATHER TIGHT AT ALL TIMES.
KEY NOTES
GRAPHIC LEGEND
DN
DN
GENERAL NOTES
A. VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE.
B. VERIFY EXACT COMPOSITION OF EXISTING WALLS TO BE REMOVED.
C. REMOVE ALL EXISTING WALL MOUNTED EQUIPMENT AND FIXTURES
AS NEEDED TO APPLY NEW FINISHES. REF. MEP DRAWINGS FOR
ADDITIONAL ITEMS AND NOTES. COORDINATE WITH NCA TO
CONFIRM SALVAGING AND DISPOSAL.
D. REFER TO MEP DRAWINGS FOR ADDITIONAL DEMOLITION ITEMS
AND NOTES. COORDINATE WORK WITH MEP REQUIREMENTS.
E. ALL EXISTING ABANDONED MEP EQUIPMENT AND ALL ASSOCIATED
PIPING AND CONDUIT DISCOVERED DURING DEMOLITION IS TO BE
REMOVED AND PROPERLY DISPOSED BY CONTRACTOR.
F. ALL EXISTING COLUMNS, BEAMS, LOAD BEARING WALLS AND
STRUCTURAL ASSEMBLIES TO REMAIN UNLESS NOTED OTHERWISE.
PROTECT DURING CONSTRUCTION.
DASHED LINE
DENOTES
ITEM TO BE
REMOVED
LINE DENOTES
ITEM TO
REMAIN
EXISTING WALLS
TO BE REMOVED
EXISTING WALLS
TO REMAIN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PROJECT ARCHITECT STAMPCONSULTANT
321 4 5 6 7 8 9 10
N/A
FORTH SMITH, AR
INTERIORSARCHITECTURE
COX DESIGN ASSOCIATES
PLANNING
Austin 5121 Bee Caves Road, Suite 203 Austin, Texas 78746 T: 512-327-4149 F: 512-327-7679e info@coxdesignassociates.com
BI
M
FO
R T
SM
IT
H N
AT
IO
N
AL
C
EM
ET
ER
Y/
FO
R T.
S M
IT
H
N
AT
IO
N
AL
C
EM
ET
ER
Y_
AR
C
H _0
1.
rv t
7/
/2
:0 1:
A
M
AD-102
LODGE BLDG. FLOOR PLANS -
DEMO
RENOVATE MAINTENANCE
FACILITY
07/15/2021 RHC MAG
847CM3020
SCALE: 3/16" = 1'-0"1 LODGE BLDG. BASEMENT FLOOR PLAN - DEMO
SCALE: 3/16" = 1'-0"2 LODGE BLDG. FIRST FLOOR PLAN - DEMO
SCALE: 3/16" = 1'-0"3 LODGE BLDG. SECOND FLOOR PLAN - DEMO
SCALE: 3/16" = 1'-0"4 LODGE BLDG. ROOF PLAN - DEMO
1 REMOVE EXISTING BATHTUB, LAVATORY, CASEWORK, CEILING,
WALL FINISH ASSEMBLIES AND PREPARE ROOM TO RECEIVE NEW
FIXTURES AND FINISHES. REF. MEP DRAWINGS.
2 REMOVE ALL EXISTING MECHANICAL DIFFUSERS AND GRILLES,
REF. MECHANICAL DRAWINGS.
3 EXISTING FLOOR FINISH ASSEMBLY TO BE REMOVED, PREPARE
SUBSTRATE FOR NEW FLOOR FINISH AS SCHEDULED.
4 EXISTING RAILING TO BE REMOVED, PREPARED FOR NEW PAINT
FINISH, REPAINTED AND REINSTALLED.
5 EXISTING STAIR TREAD NOSINGS TO BE REMOVED, REPAIR
EXISTING CONCRETE SURFACE AND PREPARE FOR NOSINGS TO
REINSTALLED. REINSTALL EXISTING NOSINGS WITH EPOXY AND
ANCHORS.
6 EXISTING RAILING TO BE PREPARED FOR NEW PAINT FINISH AND
REPAINTED.
KEY NOTES
GRAPHIC LEGEND
22 7
222224
GENERAL NOTES
A. VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE.
B. VERIFY EXACT COMPOSITION OF EXISTING WALLS TO BE REMOVED.
C. REMOVE ALL EXISTING WALL MOUNTED EQUIPMENT AND FIXTURES
AS NEEDED TO APPLY NEW FINISHES. REF. MEP DRAWINGS FOR
ADDITIONAL ITEMS AND NOTES. COORDINATE WITH NCA TO
CONFIRM SALVAGING AND DISPOSAL.
D. REFER TO MEP DRAWINGS FOR ADDITIONAL DEMOLITION ITEMS
AND NOTES. COORDINATE WORK WITH MEP REQUIREMENTS.
E. ALL EXISTING ABANDONED MEP EQUIPMENT AND ALL ASSOCIATED
PIPING AND CONDUIT DISCOVERED DURING DEMOLITION IS TO BE
REMOVED AND PROPERLY DISPOSED BY CONTRACTOR.
F. ALL EXISTING COLUMNS, BEAMS, LOAD BEARING WALLS AND
STRUCTURAL ASSEMBLIES TO REMAIN UNLESS NOTED OTHERWISE.
PROTECT DURING CONSTRUCTION.
DASHED LINE
DENOTES
ITEM TO BE
REMOVED
LINE DENOTES
ITEM TO
REMAIN
EXISTING WALLS
TO BE REMOVED
EXISTING WALLS
TO REMAIN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PROJECT ARCHITECT STAMPCONSULTANT
321 4 5 6 7 8 9 10
N/A
FORTH SMITH, AR
INTERIORSARCHITECTURE
COX DESIGN ASSOCIATES
PLANNING
Austin 5121 Bee Caves Road, Suite 203 Austin, Texas 78746 T: 512-327-4149 F: 512-327-7679e info@coxdesignassociates.com
BI
M
FO
R T
SM
IT
H N
AT
IO
N
AL
C
EM
ET
ER
Y/
FO
R T.
S M
IT
H
N
AT
IO
N
AL
C
EM
ET
ER
Y_
AR
C
H _0
1.
rv t
7/
/2
:0 1:
A
M
AD-200
MAINTENANCE BLDG. EXTERIOR
ELEVATIONS - DEMO
RENOVATE MAINTENANCE
FACILITY
07/15/2021 RHC MAG
847CM3020
SCALE: 1/4" = 1'-0"1 MAINTENANCE BLDG. EXTERIOR ELEVATION - NORTH - DEMO
SCALE: 1/4" = 1'-0"2 MAINTENANCE BLDG. EXTERIOR ELEVATION - EAST - DEMO
1 EXISTING DOOR AND FRAME - REMOVE AND DISPOSE OF ENTIRE
ASSEMBLY.
2 EXISTING BRICK VENEER - REMOVE AND REPLACE DAMAGED OR
CRACKED BRICKS (APPROXIMATELY 10% OF THIS WALL SURFACE
PLANE). EXISTING MORTAR JOINTS (APPROXIMATELY 30% OF THIS
WALL SURFACE PLANE) TO BE TUCKPOINTED AS REQUIRED.
3 EXISTING CONCRETE COPING AND ALUMINUM FLASHING TO BE
REMOVED, REPAIR (APPROXIMATELY 20% OF COPING,
CONTRACTOR TO VERIFY) AND CLEAN CONCRETE COPING AND
PREPARE EXISTING SURFACES FOR REINSTALLATION.
4 EXISTING BRICK VENEER - REMOVE AND REPLACE DAMAGED OR
CRACKED BRICKS (APPROXIMATELY 30% OF THIS WALL SURFACE
PLANE). EXISTING MORTAR JOINTS (APPROXIMATELY 30% OF THIS
WALL SURFACE PLANE) TO BE TUCKPOINTED AS REQUIRED.
5 PER STATEMENT OF WORK CHANGE BY COR, EXISTING DOOR AND
FRAME ASSEMBLY TO BE REFURBISHED AND RE-PAINTED
INCLUDING ALL COMPONENTS AND ACCESSORIES FOR A FULLY
FUNCTIONAL DOOR.
6 EXISTING WINDOW - REMOVE AND DISPOSE ENTIRE ASSEMBLY.
7 EXISTING LIGHT FIXTURE TO BE REMOVED, REF. ELECTRICAL
DRAWINGS.
8 EXISTING TRIM TO BE REMOVED AND REPLACED WITH NEW.
PREPARE TO RECEIVE NEW PAINT FINISH AS SCHEDULED.
KEY NOTES
GRAPHIC LEGEND
6 6
1 11 1
4 5
9 9
1111 11
GENERAL NOTES
A. VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE.
B. VERIFY EXACT COMPOSITION OF EXISTING WALLS TO BE REMOVED.
C. REMOVE ALL EXISTING WALL MOUNTED EQUIPMENT AND FIXTURES
AS NEEDED TO APPLY NEW FINISHES. REF. MEP DRAWINGS FOR
ADDITIONAL ITEMS AND NOTES. COORDINATE WITH NCA TO
CONFIRM SALVAGING AND DISPOSAL.
D. REFER TO MEP DRAWINGS FOR ADDITIONAL DEMOLITION ITEMS
AND NOTES. COORDINATE WORK WITH MEP REQUIREMENTS.
E. ALL EXISTING ABANDONED MEP EQUIPMENT AND ALL ASSOCIATED
PIPING AND CONDUIT DISCOVERED DURING DEMOLITION IS TO BE
REMOVED AND PROPERLY DISPOSED BY CONTRACTOR.
F. ALL EXISTING COLUMNS, BEAMS, LOAD BEARING WALLS AND
STRUCTURAL ASSEMBLIES TO REMAIN UNLESS NOTED OTHERWISE.
PROTECT DURING CONSTRUCTION.
DASHED LINE
DENOTES
ITEM TO BE
REMOVED
LINE DENOTES
ITEM TO
REMAIN
EXISTING WALLS
TO BE REMOVED
EXISTING WALLS
TO REMAIN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PROJECT ARCHITECT STAMPCONSULTANT
321 4 5 6 7 8 9 10
N/A
FORTH SMITH, AR
INTERIORSARCHITECTURE
COX DESIGN ASSOCIATES
PLANNING
Austin 5121 Bee Caves Road, Suite 203 Austin, Texas 78746 T: 512-327-4149 F: 512-327-7679e info@coxdesignassociates.com
BI
M
FO
R T
SM
IT
H N
AT
IO
N
AL
C
EM
ET
ER
Y/
FO
R T.
S M
IT
H
N
AT
IO
N
AL
C
EM
ET
ER
Y_
AR
C
H _0
1.
rv t
7/
/2
:0 2:
A
M
AD-201
MAINTENANCE BLDG. EXTERIOR
ELEVATIONS - DEMO
RENOVATE MAINTENANCE
FACILITY
07/15/2021 RHC MAG
847CM3020
SCALE: 1/4" = 1'-0"1 MAINTENANCE BLDG. EXTERIOR ELEVATION - SOUTH - DEMO
SCALE: 1/4" = 1'-0"2 MAINTENANCE BLDG. EXTERIOR ELEVATION - WEST - DEMO
1 EXISTING WINDOW - REMOVE AND DISPOSE ENTIRE ASSEMBLY.
2 EXISTING BRICK VENEER - REMOVE AND REPLACE DAMAGED OR
CRACKED BRICKS (APPROXIMATELY 10% OF THIS WALL SURFACE
PLANE). EXISTING MORTAR JOINTS (APPROXIMATELY 30% OF THIS
WALL SURFACE PLANE) TO BE TUCKPOINTED AS REQUIRED.
3 EXISTING BRICK VENEER - REMOVE AND REPLACE DAMAGED OR
CRACKED BRICKS (APPROXIMATELY 30% OF THIS WALL SURFACE
PLANE). EXISTING MORTAR JOINTS (APPROXIMATELY 30% OF THIS
WALL SURFACE PLANE) TO BE TUCKPOINTED AS REQUIRED.
4 EXISTING CONCRETE COPING AND ALUMINUM FLASHING TO BE
REMOVED, REPAIR (APPROXIMATELY 20% OF COPING,
CONTRACTOR TO VERIFY) AND CLEAN CONCRETE COPING AND
PREPARE EXISTING SURFACES FOR REINSTALLATION.
5 EXISTING ROOFING MEMBRANE TO BE REPAIRED AROUND VICINITY
OF MECHANICAL EQUIPMENT. COORDINATE WITH INSTALLATION
OF NEW MECHANICAL EQUIPMENT ASSEMBLY.
6 PER STATEMENT OF WORK CHANGE BY COR, EXISTING DOOR AND
FRAME ASSEMBLY TO BE REFURBISHED AND RE-PAINTED
INCLUDING ALL COMPONENTS AND ACCESSORIES FOR A FULLY
FUNCTIONAL DOOR.
7 EXISTING DOOR AND FRAME - REMOVE AND DISPOSE OF ENTIRE
ASSEMBLY.
8 EXISTING LIGHT FIXTURE TO BE REMOVED, REF. ELECTRICAL
DRAWINGS.
9 EXISTING GUTTER / DOWNSPOUT TO BE REMOVED, CLEANED,
REPAIRED AND COMPONENTS SHALL BE REPLACED AS NEEDED.
10 MECHANICAL EQUIPMENT, RE. MEP DRAWINGS.
11 EXISTING TRIM TO BE REMOVED AND REPLACED WITH NEW.
PREPARE TO RECEIVE NEW PAINT FINISH AS SCHEDULED.
12 EXISTING METAL PANEL ASSEMBLY TO BE REMOVED AND
PREPARED FOR NEW PAINT FINISH, PAINTED AND REINSTALLED
AFTER NEW FLASHING IS INSTALLED.
KEY NOTES
GRAPHIC LEGEND
AS-201
AS-200
1LOCKER BREAK
MB107
RESTROOM
MB106
UNISEX TOILET
MB102
EQUIPMENT
STORAGE
MB103
EQUIPMENT
STORAGE
MB101
SHOWER
MB108
AS-200 2
AS-201
A A AA
04 03 02 01
B
C
D
AS-1002
VI
F
2'
3/
4" 4'
6"
2' - 1"
1 1
1 1
6 6 6 6
9 9 9
11 11 11 11 11
12 12 12 12
12 12
FIRST FLOOR
0' - 0"
2'
6" 1'
6"
2'
1' - 0"
CLEAR
2' - 6" 1' - 0"
1' - 0" 2' - 6" 1' - 0"
4' - 6"
VIF
2' - 8 3/4" 4' - 6"
AS-100
2'
6"
1/4" PLYWOOD BACKING
3/4" PLYWOOD CABINET DOOR
WITH PLASTIC
LAMINATE FINISH AT
ALL SURFACES
DOUBLE SLOTTED
METAL STANDARDS -
FLUSH MOUNTED
(TYPICAL)
PROVIDE FIRE
RETARDENT TREATED
2X6 WOOD BLOCKING
AS REQUIRED
PROVIDE FIRE
RETARDENT TREATED
2X6 WOOD BLOCKING
AS REQUIRED
3/4" ADJUSTABLE
PLYWOOD SHELVING
WITH PLASTIC LAMINATE
FINISH AT ALL SURFACES
FIRE RETARDENT TREATED
2X8 CONTINUOUS FRAMING
AT CABINETS CUT
BETWEEN STUDS
2' - 0"
0' - 8"
0'
1/
2" 0'
2"
0' - 6"
0'
9"
2'
R
EF
ER
T
O
IN
TE
R
IO
R
E
LE
VA
TI
O N
S
PLASTIC LAMINATE
COUNTERTOP, BACKSPLASH,
AND EDGES AS SCHEDULED
ON (2) LAYERS OF PLYWOOD
PLYWOOD BRACE LOCATED
BETWEEN LAVATORIES
PLASTIC LAMINATE APRON
COVER, SCREW ATTACHED
TO END SUPPORTS WITH
OVAL HEAD SCREWS AND
ESCUTCHEONS
BASE AS SCHEDULED
1' - 0"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PROJECT ARCHITECT STAMPCONSULTANT
321 4 5 6 7 8 9 10
N/A
FORTH SMITH, AR
INTERIORSARCHITECTURE
COX DESIGN ASSOCIATES
PLANNING
Austin 5121 Bee Caves Road, Suite 203 Austin, Texas 78746 T: 512-327-4149 F: 512-327-7679e info@coxdesignassociates.com
BI
M
FO
R T
SM
IT
H N
AT
IO
N
AL
C
EM
ET
ER
Y/
FO
R T.
S M
IT
H
N
AT
IO
N
AL
C
EM
ET
ER
Y_
AR
C
H _0
1.
rv t
7/
/2
:0 2:
A
M
AS-100
MAINTENANCE BLDG. FLOOR
PLAN
RENOVATE MAINTENANCE
FACILITY
07/15/2021 RHC MAG
847CM3020
1 NEW LOCKABLE TOOL/EQUIPMENT CABINET, 60"W X 20"D X 84"H,
TYPICAL.
2 NEW PAINT COAT ON ALL WALLS IN THIS AREA.
3 NEW WALL, 5/8" GYP BD. OVER 1 5/8" METAL STUDS WRAPPING
AROUND EXISTING BRICK COLUMN.
4 NEW PLUMBING FIXTURE, REF. MEP DRAWINGS.
5 NEW CASEWORK.
6 NEW 12"X24" CONCRETE SPLASHBLOCK.
7 NEW FLOOR FINISH AS SCHEDULED.
8 EXISTING RELOCATED LOCKERS.
9 NEW DOOR AND FRAME ASSEMBLY.
10 PER STATEMENT OF WORK CHANGE BY COR, EXISTING DOOR AND
FRAME ASSEMBLY TO BE REFURBISHED AND RE-PAINTED
INCLUDING ALL COMPONENTS AND ACCESSORIES FOR A FULLY
FUNCTIONAL DOOR.
11 NEW WINDOW ASSEMBLY.
12 PATCH, REPAIR AND PAINT ADJACENT WALL FINISHES AROUND
WINDOW/DOOR.
SCALE: 1/4" = 1'-0"1 MAINTENANCE BLDG. FLOOR PLAN
SCALE: 1/2" = 1'-0"2 INTERIOR ELEVATION - BREAK ROOM KITCHEN
KEY NOTES
SCALE: 1" = 1'-0"3 MILLWORK DETAIL
DN DN
AS-102
RESTROOM
AS-102
3'
1"
2' - 1"
1'
6"6
2ND LVL (LODGE)
14' - 10 1/32"
PT-1
CT-1
CT-12'
2ND LVL (LODGE)
14' - 10 1/32"
3' - 1"
2'
M
AX
3'
4"
1' - 6"
PT-1
CT-1
3'
6"
AS-100
2ND LVL (LODGE)
14' - 10 1/32"
CT-1
PT-1
1'
3"
0' - 7"
2ND LVL (LODGE)
14' - 10 1/32"
3'
6" CT-1
PT-1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PROJECT ARCHITECT STAMPCONSULTANT
321 4 5 6 7 8 9 10
N/A
FORTH SMITH, AR
INTERIORSARCHITECTURE
COX DESIGN ASSOCIATES
PLANNING
Austin 5121 Bee Caves Road, Suite 203 Austin, Texas 78746 T: 512-327-4149 F: 512-327-7679e info@coxdesignassociates.com
BI
M
FO
R T
SM
IT
H N
AT
IO
N
AL
C
EM
ET
ER
Y/
FO
R T.
S M
IT
H
N
AT
IO
N
AL
C
EM
ET
ER
Y_
AR
C
H _0
1.
rv t
7/
/2
:0 2:
A
M
AS-102
LODGE BLDG. FLOOR PLANS RENOVATE MAINTENANCE
FACILITY
07/15/2021 Checker Author
847CM3020
SCALE: 3/16" = 1'-0"1 LODGE BLDG. BASEMENT FLOOR PLAN SCALE: 3/16" = 1'-0"2 LODGE BLDG. FIRST FLOOR PLAN
SCALE: 3/16" = 1'-0"3 LODGE BLDG. SECOND FLOOR PLAN
SCALE: 3/16" = 1'-0"9 LODGE BLDG. ROOF PLAN
1 NEW CASEWORK.
2 NEW LIGHTNING PROTECTION SYSTEM, REF. ELECTRICAL
DRAWINGS.
3 NEW PLUMBING FIXTURE, REF. MEP DRAWINGS.
4 NEW CEILING ASSEMBLY AS SCHEDULED.
5 NEW FLOOR FINISH AS SCHEDULED.
6 NEW TILE BACKER BOARD SUBSTRATE OVER EXISTING STUDS,
PREPARE SURFACE FOR NEW WALL FINISHES AS SCHEDULED.
7 NEW STAINLESS STEEL TOILET TISSUE DISPENSER, ADD
ALTERNATE.
8 NEW 24"W X 36"H STAINLESS STEEL MIRROR, ADD ALTERNATE.
9 NEW STAINLESS STEEL PAPER TOWEL DISPENSER, ADD
ALTERNATE.
10 NEW STAINLESS STEEL SOAP DISPENSER, ADD ALTERNATE.
11 REFERENCE MEP DRAWINGS FOR CEILING MOUNTED FIXTURES
NOT SHOWN HERE.
KEY NOTES
SCALE: 3/8" = 1'-0"4 ENLARGED PLAN - RESTROOM
SCALE: 3/8" = 1'-0"5 INTERIOR ELEVATION - RESTROOM SOUTH
SCALE: 3/8" = 1'-0"6 INTERIOR ELEVATION - RESTROOM EAST
SCALE: 3/8" = 1'-0"8 INTERIOR ELEVATION - RESTROOM NORTH
SCALE: 3/8" = 1'-0"7 INTERIOR ELEVATION - RESTROOM WEST
SIM.
AS-201
AS-200
AS-200 2
AS-201
2 2
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PROJECT ARCHITECT STAMPCONSULTANT
321 4 5 6 7 8 9 10
N/A
FORTH SMITH, AR
INTERIORSARCHITECTURE
COX DESIGN ASSOCIATES
PLANNING
Austin 5121 Bee Caves Road, Suite 203 Austin, Texas 78746 T: 512-327-4149 F: 512-327-7679e info@coxdesignassociates.com
BI
M
FO
R T
SM
IT
H N
AT
IO
N
AL
C
EM
ET
ER
Y/
FO
R T.
S M
IT
H
N
AT
IO
N
AL
C
EM
ET
ER
Y_
AR
C
H _0
1.
rv t
7/
/2
:0 2:
A
M
AS-103
MAINTENANCE BLDG. ROOF
PLAN
RENOVATE MAINTENANCE
FACILITY
07/15/2021 RHC MAG
847CM3020
1 NEW LIGHTNING PROTECTION SYSTEM, REF. ELECTRICAL
DRAWINGS.
2 MECHANICAL EQUIPMENT, RE. MEP DRAWINGS.
3 NEW MECHANICAL EQUIPMENT, REF. MEP DRAWINGS.
4 EXISTING ROOFING MEMBRANE TO BE REPAIRED AROUND VICINITY
OF MECHANICAL EQUIPMENT. COORDINATE WITH INSTALLATION
OF NEW MECHANICAL EQUIPMENT ASSEMBLY.
5 EXISTING REPAIRED CONCRETE COPING TO BE REINSTALLED,
PROVIDE NEW ALUMINUM FLASHING ASSEMBLY BELOW COPING.
SCALE: 1/4" = 1'-0"1 MAINTENANCE BLDG. ROOF PLAN
KEY NOTES
9' - 0"
9' - 0"
9' - 0"
9' - 0"
EQUIPMENT
STORAGE
MB103
LOCKER BREAK
MB107
RESTROOM
MB106
UNISEX TOILET
MB102
SHOWER
MB108
EQUIPMENT
STORAGE
MB101
OS OS OS OS
OS
OS
OS
OS
OS
2'-0" x 2'-0"
SUSPENDED
EXPOSED GRID
ACOUSTIC CEILING
TILE
2' X 4' LUMINAIRE
DOWNLIGHT
SUPPLY GRILLE
EXHAUST GRILLE
RETURN GRILLE
EXHAUST GRILLE
SMOKE DETECTORSD
CEILING HEIGHT,
ABOVE FINISHED
FLOOR
+8'-0" A.F.F
OCCUPANCY SENSOROS
SINGLE SIDED EXIT SIGNAGE CEILING MOUNTED
WITH DIRECTIONAL ARROWS
DOUBLE SIDED EXIT SIGNAGE CEILING MOUNTED
WITH DIRECTIONAL ARROWS
DOUBLE SIDED EXIT SIGNAGE CEILING MOUNTED
SINGLE SIDED EXIT SIGNAGE CEILING MOUNTED
EXHAUST GRILLE
1' X 4' LUMINAIRE
EMERGENCY LIGHT
FIXTURE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PROJECT ARCHITECT STAMPCONSULTANT
321 4 5 6 7 8 9 10
N/A
FORTH SMITH, AR
INTERIORSARCHITECTURE
COX DESIGN ASSOCIATES
PLANNING
Austin 5121 Bee Caves Road, Suite 203 Austin, Texas 78746 T: 512-327-4149 F: 512-327-7679e info@coxdesignassociates.com
BI
M
FO
R T
SM
IT
H N
AT
IO
N
AL
C
EM
ET
ER
Y/
FO
R T.
S M
IT
H
N
AT
IO
N
AL
C
EM
ET
ER
Y_
AR
C
H _0
1.
rv t
7/
/2
:0 2:
A
M
AS-130
MAINTENANCE BLDG.
REFLECTED CEILING PLAN
RENOVATE MAINTENANCE
FACILITY
07/15/2021 RHC MAG
847CM3020
SCALE: 1/4" = 1'-0"1 MAINTENANCE BLDG. REFLECTED CEILING PLAN
GRAPHIC LEGEND
KEY NOTES
1 NEW CEILING ASSEMBLY AS SCHEDULED.
2 REFERENCE MEP DRAWINGS FOR CEILING MOUNTED FIXTURES
NOT SHOWN HERE.
C
03 02 01
1 1
6 6
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PROJECT ARCHITECT STAMPCONSULTANT
321 4 5 6 7 8 9 10
N/A
FORTH SMITH, AR
INTERIORSARCHITECTURE
COX DESIGN ASSOCIATES
PLANNING
Austin 5121 Bee Caves Road, Suite 203 Austin, Texas 78746 T: 512-327-4149 F: 512-327-7679e info@coxdesignassociates.com
BI
M
FO
R T
SM
IT
H N
AT
IO
N
AL
C
EM
ET
ER
Y/
FO
R T.
S M
IT
H
N
AT
IO
N
AL
C
EM
ET
ER
Y_
AR
C
H _0
1.
rv t
7/
/2
:0 2:
A
M
AS-200
MAINTENANCE BLDG. -
EXTERIOR ELEVATIONS
RENOVATE MAINTENANCE
FACILITY
07/15/2021 RHC MAG
847CM3020
1 NEW LIGHT FIXTURE, REF. ELECTRICAL DRAWINGS.
2 EXISTING CONCRETE COPING TO BE REINSTALLED.
3 EXISTING BRICK VENEER - REMOVE AND REPLACE DAMAGED OR
CRACKED BRICKS (APPROXIMATELY 10% OF THIS WALL SURFACE
PLANE). EXISTING MORTAR JOINTS (APPROXIMATELY 10% OF THIS
WALL SURFACE PLANE) TO BE TUCKPOINTED AS REQUIRED.
4 EXISTING BRICK VENEER - REMOVE AND REPLACE DAMAGED OR
CRACKED BRICKS (APPROXIMATELY 30% OF THIS WALL SURFACE
PLANE). EXISTING MORTAR JOINTS (APPROXIMATELY 30% OF THIS
WALL SURFACE PLANE) TO BE TUCKPOINTED AS REQUIRED.
5 PER STATEMENT OF WORK CHANGE BY COR, EXISTING DOOR AND
FRAME ASSEMBLY TO BE REFURBISHED AND RE-PAINTED
INCLUDING ALL COMPONENTS AND ACCESSORIES FOR A FULLY
FUNCTIONAL DOOR.
6 NEW DOOR AND FRAME ASSEMBLY.
SCALE: 1/4" = 1'-0"1 MAINTENANCE BLDG. EXTERIOR ELEVATION - NORTH
SCALE: 1/4" = 1'-0"2 MAINTENANCE BLDG. EXTERIOR ELEVATION - EAST
KEY NOTES
1 1
06 05
A A A A B
D
7 7
999 9 9 9
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PROJECT ARCHITECT STAMPCONSULTANT
321 4 5 6 7 8 9 10
N/A
FORTH SMITH, AR
INTERIORSARCHITECTURE
COX DESIGN ASSOCIATES
PLANNING
Austin 5121 Bee Caves Road, Suite 203 Austin, Texas 78746 T: 512-327-4149 F: 512-327-7679e info@coxdesignassociates.com
BI
M
FO
R T
SM
IT
H N
AT
IO
N
AL
C
EM
ET
ER
Y/
FO
R T.
S M
IT
H
N
AT
IO
N
AL
C
EM
ET
ER
Y_
AR
C
H _0
1.
rv t
7/
/2
:0 2:
A
M
AS-201
MAINTENANCE BLDG. -
EXTERIOR ELEVATIONS
RENOVATE MAINTENANCE
FACILITY
07/15/2021 RHC MAG
847CM3020
1 NEW LIGHT FIXTURE, REF. ELECTRICAL DRAWINGS.
2 EXISTING CONCRETE COPING TO BE REINSTALLED.
3 EXISTING METAL PANEL ASSEMBLY TO BE REMOVED AND
PREPARED FOR NEW PAINT FINISH, PAINTED AND REINSTALLED
AFTER NEW FLASHING IS INSTALLED.
4 PER STATEMENT OF WORK CHANGE BY COR, EXISTING DOOR AND
FRAME ASSEMBLY TO BE REFURBISHED AND RE-PAINTED
INCLUDING ALL COMPONENTS AND ACCESSORIES FOR A FULLY
FUNCTIONAL DOOR.
5 NEW DOOR AND FRAME ASSEMBLY.
6 EXISTING BRICK VENEER - REMOVE AND REPLACE DAMAGED OR
CRACKED BRICKS (APPROXIMATELY 10% OF THIS WALL SURFACE
PLANE). EXISTING MORTAR JOINTS (APPROXIMATELY 30% OF THIS
WALL SURFACE PLANE) TO BE TUCKPOINTED AS REQUIRED.
7 EXISTING BRICK VENEER - REMOVE AND REPLACE DAMAGED OR
CRACKED BRICKS (APPROXIMATELY 10% OF THIS WALL SURFACE
PLANE). EXISTING MORTAR JOINTS (APPROXIMATELY 10% OF THIS
WALL SURFACE PLANE) TO BE TUCKPOINTED AS REQUIRED.
8 EXISTING BRICK VENEER - REMOVE AND REPLACE DAMAGED OR
CRACKED BRICKS (APPROXIMATELY 30% OF THIS WALL SURFACE
PLANE). EXISTING MORTAR JOINTS (APPROXIMATELY 30% OF THIS
WALL SURFACE PLANE) TO BE TUCKPOINTED AS REQUIRED.
9 NEW WINDOW ASSEMBLY.
SCALE: 1/4" = 1'-0"1 MAINTENANCE BLDG. EXTERIOR ELEVATION - SOUTH
SCALE: 1/4" = 1'-0"2 MAINTENANCE BLDG. EXTERIOR ELEVATION - WEST
KEY NOTES
MIN. 3000 PSI CONCRETE REQ'D
GA0232 - 4 1/4"GA0232 - 4 1/4"
COILEXTERIOR
CP0001
FRONT
SLAT
BACK SLAT
POLYURETHANE
INSULATION
ASTRAGAL
BOTTOM BAR / SLAT DETAIL
WEATHERING
4" x 3 1/2" x 1/4"4" x 3 1/2" x 1/4"
4 1/4"
1/2" 1/2"
2 1/2"
6 1/4"
7 1/4"
4 1/4"
2 1/2"
6 1/4"
7 1/4"
7/8"3"
4"
16'-1"
16'-0"
36" 36"36" 36"
MK: 001
HEX HEAD CAP SCREW, GR. 8
- HEX HEAD NUT, GR. 8
- HARDENED FLAT WASHERS
HEX HEAD CAP SCREW, GR. 8
- HEX HEAD NUT, GR. 8
- HARDENED FLAT WASHERS
x 3-1/2"
MIN. EMBEDMENT DEPTH - 2-5/8"
SIMPSON WEDGE-ALL, - Ø3/8"
MIN. EMBEDMENT DEPTH - 2-5/8"
x 3-1/2"
MIN. 3000 PSI CONCRETE REQ'D
- Ø3/8" SIMPSON WEDGE-ALL,
1089 LBS STATIC LOAD
DESIGNED TO SUPPORT
STRUCTURE MUST BE
- Ø3/8-16 x 1-1/2" - Ø3/8-16 x 1-1/2"
AT ON CENTERAT ON CENTERAT ON CENTER AT ON CENTER
OPENING WIDTH
DISTANCE BETWEEN GUIDES
3/16" STEEL BRACKET PLATE ABOVE
PLAN OF OPENING
3" x 2" x 3/16" (TYP.)
3 1/2" x 3" x 1/4" (TYP.)
ASSEMBLY FASTENERS:WALL FASTENERS:WALL FASTENERS: ASSEMBLY FASTENERS:
2 3/4" 1 3/8"
1 1/2"
1 1/8"
2 3/4" 1 3/8"
1 1/8"
1 1/2"
AUXILIARY
HAND CHAIN
12-1/8"±
1-1/2" TOP HOOD BEAD
2"
O
PE
N
IN
G H
EI
G
H T
'L-TYPE' LINTEL
BRUSH SEAL
5"
?19-1/2"
O
VE
R
AL
L D
O O
R H
EI
G
H T
D O
O R
O
PE
N
IN
G H
EI
G
H T
WIDTH
H
EI
G H
T
TYPE "A"
FLUSH
TYPE "B"
ROLL-UP DOOR
WIDTH
H
EI
G
H T
TYPE "A"
HOLLOW METAL FRAME
SINGLE DOOR
TYPE "B"
STEEL ROLL-UP
DOOR FRAME
2" DOOR WIDTH 2"
2" D
O O
R H
EI
G
H T
2" DOOR WIDTH 2"
2" D
O O
R H
EI
G
H T
TYPE WIDTH
WINDOW SCHEDULE
HEIGHT GLAZING FRAME COMMENTS
A 3' - 6" 4' - 0" ALUMINUM
B 3' - 6" 3' - 0" ALUMINUM
C 1' - 4" 4' - 0" ALUMINUM
D 3' - 6" 1' - 4" CLEAR, LAMINATED, DOUBLE INSULATED, LOW-E ALUMINUM
U-VALUE SHGC
0.30 0.40
CLEAR, LAMINATED, DOUBLE INSULATED, LOW-E 0.30 0.40 FIELD VERIFY EXISTING WINDOW SIZE
CLEAR, LAMINATED, DOUBLE INSULATED, LOW-E
CLEAR, LAMINATED, DOUBLE INSULATED, LOW-E
0.30 0.40
0.30 0.40
FIELD VERIFY EXISTING WINDOW SIZE
FIELD VERIFY EXISTING WINDOW SIZE
FIELD VERIFY EXISTING WINDOW SIZE
2'
8" 4'
0"
3' - 6"
3'
8" 3'
0"
3' - 6"
4'
0" 4'
0"
1' - 4"
5'
4" 1'
4"
3' - 6"
TYPE "A" TYPE "B" TYPE "C" TYPE "D"3 3/4" 2"2"
7 5/8"
EXISTING WALL
ASSEMBLY
SEALANT
(BOTH SIDES)
HOLLOW METAL
DOOR FRAME
DOOR AS
SCHEDULED
3 3/4" 2"2"
2" 2"
7 5/8"
EXISTING WALL ASSEMBLY
SEALANT
(BOTH SIDES)
HOLLOW METAL
DOOR FRAME
DOOR AS
SCHEDULED
EXISTING WALL ASSEMBLY
EXISTING LINTEL
1/4" SHIM SPACE
WINDOW AS SCHEDULED
AIR SPACE
EXISTING FLASHING
EXISTING
FACE BRICK
SEALANT
METAL FLASHING
WITH DRIP
CONTINUOUS
BEAD OF SEALANT
(BOTH SIDES
OF WALL)
EXISTING WALL ASSEMBLY
1/4" SHIM SPACE
WINDOW AS SCHEDULED
AIR SPACE
EXISTING FLASHING,
OVERLAP NEW
FLASHING WITH
EXISTING FLASHING
EXISTING
FACE BRICK
CONTINUOUS
BEAD OF SEALANT
(BOTH SIDES
OF WALL)
EXISTING WALL ASSEMBLY
1/4" SHIM SPACE WINDOW AS SCHEDULED
AIR SPACE
EXISTING FLASHING,
OVERLAP NEW
FLASHING WITH
EXISTING FLASHING
EXISTING
FACE BRICK
CONTINUOUS
BEAD OF SEALANT
(BOTH SIDES
OF WALL)
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PROJECT ARCHITECT STAMPCONSULTANT
321 4 5 6 7 8 9 10
N/A
FORTH SMITH, AR
INTERIORSARCHITECTURE
COX DESIGN ASSOCIATES
PLANNING
Austin 5121 Bee Caves Road, Suite 203 Austin, Texas 78746 T: 512-327-4149 F: 512-327-7679e info@coxdesignassociates.com
BI
M
FO
R T
SM
IT
H N
AT
IO
N
AL
C
EM
ET
ER
Y/
FO
R T.
S M
IT
H
N
AT
IO
N
AL
C
EM
ET
ER
Y_
AR
C
H _0
1.
rv t
7/
/2
:0 2:
A
M
AS-600
DOOR / WINDOW / ROOM
SCHEDULES AND DETAILS
RENOVATE MAINTENANCE
FACILITY
07/15/2021 RHC MAG
847CM3020
DOOR SCHEDULE
DOOR
NUMBER
DOOR FRAME HARDWARE
GROUP NOTESWIDTH HEIGHT MATERIAL FINISH TYPE MATERIAL FINISH TYPE
01 16' - 0" 10' - 2" ALUMINUM N/A B STEEL N/A B HW-6 DOOR TO HAVE U-VALUE OF 0.125 02 16' - 0" 10' - 2" ALUMINUM N/A B STEEL N/A B HW-6 DOOR TO HAVE U-VALUE OF 0.125 03 8' - 0" 10' - 2" ALUMINUM N/A B STEEL N/A B HW-6 DOOR TO HAVE U-VALUE OF 0.125 04 3' - 0" 7' - 0" HOLLOW METAL PT A HOLLOW METAL PT A HW-14 DOOR TO HAVE U-VALUE OF 0.40 05 16' - 0" 10' - 2" ALUMINUM N/A B STEEL N/A B HW-6 DOOR TO HAVE U-VALUE OF 0.125 06 16' - 0" 10' - 2" ALUMINUM N/A B STEEL N/A B HW-6 DOOR TO HAVE U-VALUE OF 0.125 07 16' - 0" 10' - 2" ALUMINUM N/A B STEEL N/A B HW-6 DOOR TO HAVE U-VALUE OF 0.125
08 2' - 0" 7' - 0" HOLLOW METAL PT A HOLLOW METAL PT B HW-7
Grand total: 8
SCALE: 1/2" = 1'-0"
DOOR TYPES
SCALE: 1/2" = 1'-0"2 FRAME TYPES
SCALE: 1/2" = 1'-0"
WINDOW TYPES10
SCALE: 3" = 1'-0"3 HM DOOR FRAME HEAD
SCALE: 3" = 1'-0"4 HM DOOR FRAME JAMB
ROOM FINISH SCHEDULE
ROOM
NUMBER ROOM NAME FLOOR BASE NORTH EAST SOUTH WEST CEILING WINDOW TREATMENT REMARKS
L100 RESTROOM CT-2 CT-1 PT-1 / CT-1 PT-1 / CT-1 PT-1 / CT-1 PT-1 / CT-1 GYP BD. PT-1
MB101 EQUIPMENT STORAGE N/A N/A PT-1 PT-1 PT-1 PT-1 EXISTING
MB103 EQUIPMENT STORAGE N/A N/A PT-1 PT-1 PT-1 PT-1 EXISTING
MB107 LOCKER BREAK N/A RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1
MATERIAL FINISH SCHEDULE
FINISH CODE MATERIAL TYPE BASIS OF DESIGN MANUFACTURE NO. PATTERN COLOR SIZE GROUT COMMENTS
ACT-1 ACOUSTICAL CEILING
TILE
ARMSTRONG --- WHITE 2' X 2' ---
CT-1 CERAMIC TILE INTERCERAMIC --- SUBWAY WALL TILE COLLECTION BONE WHITE 3" X 6" LIGHT GRAY PROVIDE TILE AND GROUT FULL COLOR SAMPLES FOR REVIEW.
CT-2 CERAMIC TILE INTERCERAMIC --- CATALINA PEBBLE 13" X 13" LIGHT GRAY PROVIDE TILE AND GROUT FULL COLOR SAMPLES FOR REVIEW.
PT-1 PAINT COORDINATE W/ NCA --- --- WHITE TO
MATCH
EXISTING
--- COORDINATE WITH NCA FOR EXISTING PAINT MANUFACTURER'S INFORMATION.
RB-1 RUBBER WALL BASE ARMSTRONG --- --- FLAGSTONE 4" ---
SCALE: 1 1/2" = 1'-0"5 WINDOW HEAD DETAIL
SCALE: 1 1/2" = 1'-0"6 WINDOW JAMB DETAIL
SCALE: 1 1/2" = 1'-0"7 WINDOW SILL DETAIL
SCALE: 3" = 1'-0"8 ROLL UP DOOR DETAILS
SCALE: 3/4" = 1'-0"9 ROLL UP DOOR SECTION
(E)WC-1
(E)L-1
(E)B-1
| FT._SMITH_DRAWINGS_BIDSET_07152021.pdf |
| Sheets |
| AD-100 - MAINTENANCE BLDG. FLOOR PLAN - DEMO |
| AD-101 - MAINTENANCE BLDG. ROOF PLAN - DEMO |
| AD-102 - LODGE BLDG. FLOOR PLANS - DEMO |
| AD-200 - MAINTENANCE BLDG. EXTERIOR ELEVATIONS - DEMO |
| AD-201 - MAINTENANCE BLDG. EXTERIOR ELEVATIONS - DEMO |
| AS-100 - MAINTENANCE BLDG. FLOOR PLAN |
| AS-102 - LODGE BLDG. FLOOR PLANS |
| AS-103 - MAINTENANCE BLDG. ROOF PLAN |
| AS-130 - MAINTENANCE BLDG. REFLECTED CEILING PLAN |
File details come from the government source that posted it. Updated .