S02 - 556-23-104 CD Drawings.pdf

PDF 17 MB Posted

Attached to
Z1DA--556-23-104 Chilled Water Piping From Bldg. 188 to Bldg. 3
Solicitation number
36C25225B0002
Issued by

About this file

This is a construction drawing set for a chilled water piping project at the Captain James A. Lovell Federal Health Care Center (FHCC) in North Chicago, IL, connecting Building 188 to Building 3. The drawings detail architectural, mechanical, and electrical specifications for installing chilled water piping through multiple buildings and tunnels, with project number 556-23-104.

The drawing set includes site plans, floor plans, demolition plans, sections, and technical details for routing chilled water piping through Buildings 188, 4, 3, and connecting corridors. Key components include pipe penetrations through walls and floors, bypass valve assemblies, pressure sensors, and associated electrical work. The project includes three deduct alternates affecting different segments of the piping route. The drawings specify fully sprinklered requirements and include detailed sections for tunnel penetrations, access doors, concrete work, and mechanical/electrical interfaces. The work is being managed by the VA Office of Construction and Facilities Management, with Harrell Design Group PC as the architect/engineer of record.

View the file

Other files

File Type Posted
S06 - Wage Determination eff 3.21.2025.pdf PDF
36C25225B0002 0009.docx DOCX document
Provision and Clause Changes.pdf PDF
36C25225B0002 0008.docx DOCX document
S06 - VAAR 852.219-75_Submit with Bid.pdf PDF
S06 - 556-23-104 Amendment 0007_Attachment.pdf PDF
36C25225B0002 0007.docx DOCX document
36C25225B0002 0006.docx DOCX document
36C25225B0002 0005.docx DOCX document
36C25225B0002 0004.docx DOCX document
36C25225B0002 0003.docx DOCX document
2ndWALK-THRU SIGN-IN SHEET FHCC NORTH CHICAGO.pdf PDF
36C25225B0002 0002.docx DOCX document
36C25225B0002 0001.docx DOCX document
WALK THRU SIGN-IN SHEET Jan 21 2025-FHCC North Chicago.pdf PDF
S02 - 556-23-104 Addendum correcting select specification text rev20DEC24.docx DOCX document
S02 - 556-23-104 CD Specifications.pdf PDF
36C25225B0002_1.docx DOCX document
S02 - Wage Determination.pdf PDF
S02 - SECTION 01 35 26.docx DOCX document
S02 - Section 01 35 33.docx DOCX document
Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PIPING - SEE

MECHANICAL DRAWINGS

EXISTING CMU

CHASE

EXISTING CMU

CHASE

EXISTING H.M.

DOUBLE DOORS

E2

AE402

J

K

NEW EXPANSION JOINT

COVER - SEE B1/AF101

AREA OF FLOOR FLOOR

SLAB INFILL

MAINTAIN 6" CLEAR OF

WALL AND DOOR FRAME

FOR FLOOR SLAB

DEMOLITION AND INFILL

1' -0

PROTECT EXISTING

PIPING

PROTECT EXISTING H.M.

DOOR AND DOOR FRAME

EXISTING CONCRETE

SLAB FLOOR ON

GRADE

EXISTING CONCRETE

SLAB FLOOR (TUNNEL

BELOW)

13'-0"

6"

6"

6"

6"

4"

E6

AE403

CONTROL JOINT (CJ)

CJ

C J

CJ

C J

PROTECT EXISTING

CONDUIT RUNS

STAINLESS STEEL ESCUTCHEON RING

AT EACH PIPE PENETRATION

BOLLARDBOLLARDBOLLARD

2'-4" 2'-4"

4'-5"

FACE OF BOLLARDS FLUSH

WITH DOOR FRAME

EQ. EQ.

BLDG

BLDG

BLDG

BLDG

CONNECTING

CORRIDOR TOP

OF STEEL

11'-4"

FLOOR

0'-0"

3' -0

CONNECTING

CORRIDOR

BOTTOM OF BEAM

9'-7 3/8"

9'-0"

2' -0

1'-6"6"

10"

LAYER OF SAND OR FINE

GRAVEL PLACED AND

TAMPED IN TRENCH

INSULATED PIPE - SEE

MECHANICAL DRAWINGS

NEW CONCRETE

INFILL TO MATCH

EXISTING

AREA OF EXCAVATION IN CORRIDOR

AREA OF EXCAVATION AT DOORS

SAND OR FINE GRAVEL, COMPACTED

NEW PIPE WITH PIPE

HANGERS- SEE

MECHANICAL

DRAWINGS

EXISTING STRUCTURAL

STEEL

PROTECT EXISTING H.M.

DOORS AND DOOR FRAME

CONNECTING CORRIDOR

FROM BUILDING 188 TO

TRAMWAY

VAPOR BARRIER

WITH 4" GRAVEL

4"

STAINLESS STEEL ESCUTCHEON RING

AT EACH PIPE PENETRATION

#3@12" O.C.. EACH WAY, TOP AND

BOTTOM (TYPICAL)

PIPE ELBOW

SEE B3/AF101 FOR CONNECTION

E6

AE403

COORDINATE WITH

MECH DRAWINGS

3' -5

EXISTING CONDUIT

EXISTING FIRE PIPE

EXISTING INSULATED PIPE

PROJECT NUMBER

BUILDING NUMBER

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

APPROVED

A

FULLY SPRINKLERED

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASEARCHITECT/ENGINEER OF RECORD

A/E:

STAMP

321 4 5 6 7 8 9 10

HARRELL DESIGN GROUP PC

10720 SIKES PLACE, SUITE 100

CHARLOTTE, NC 28227

704-814-1346 POC: LEE HARRELL PE, LEED AP, QCxP

PRESIDENT

COPYRIGHT © 2024

556-23-104

JULY 26, 2024

CAPTAIN JAMES A. LOVELL FEDERAL HEALTH CARE

CENTER (FHCC)

CHILLED WATER FROM B188 TO B3100% CONSTRUCTION

DOCUMENTS - ISSUED

FOR CONSTRUCTION

HDG PROJECT: 22018Revision Number Revisions: Date:

CONTRACT NO. - 36C25219D0022

TASK ORDER NO. - 36C25223N0287

AE402

CORRIDOR PLAN AND SECTION

X

GGJC

GENERAL SHEET NOTES

A. FIELD VERIFY EXISTING OPENINGS PRIOR TO FABRICATION.

B. USE EXISTING DOORS AS A MODEL FOR CONSTRUCTION NEW

DOORS.

C. ALL GRILLES TO BE GALVANIZED, PAINTED.

D. ALL WOOD TO BE TREATED, PAINTED.

E. CONTROL JOINT THICKNESS IS EXISTING SLAB. USE STRIPPABLE

CONTROL JOINT.

F. STOP REINFORCING EACH SIDE OF JOINT.

SHEET KEYNOTES 1

SEE F5/MP101 FOR MECHANICAL PLAN.

EXISTING WALL

PRE-INSULATED

CHILLED WATER

PIPING - SEE

MECHANICAL

DRAWINGS

BACKER ROD AND

SEALANT

BACKER ROD AND SEALANT

E6

AE402

E6

AE402

KEYPLANKEYPLAN

1 50% DD RESUBMISSION 08/29/2023

2 75% DD 05/17/2024

3 95% DD 06/18/2024

4 100% CD 07/26/2024

NOTES:

SEE E6/AE401 FOR LOCATION OF WALL

PENETRATION.

THIS DETAIL APPLIES TO ABOVE GRADE ONLY.

F8

MP501

2-HOUR RATED PARTITION

WALL RATING LEGEND

AREA OF

EXCAVATION

CHILLED WATER

PIPING - SEE

MECHANICAL

DRAWINGS

PROTECT LIGHTNING

PROTECTION

GROUND RING

BELOW GRADE

WATERPROOFING AT

EXPOSED CONCRETE

SEAL PIPE. SEE

F8/MP501

SEAL PIPE. SEE

F8/MP501

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text 3/4" = 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text 1'

AutoCAD SHX Text 2'

AutoCAD SHX Text 3'

AutoCAD SHX Text

CORRIDOR PLAN

AutoCAD SHX Text E6

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

NONE

AutoCAD SHX Text

SECTION-MECHANICAL

AutoCAD SHX Text

PENETRATION TRAMWAY WALL

AutoCAD SHX Text B4

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text 3/4" = 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text 1'

AutoCAD SHX Text 2'

AutoCAD SHX Text 3'

AutoCAD SHX Text

CORRIDOR SECTION

AutoCAD SHX Text E2

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text

NW

AutoCAD SHX Text

SW

AutoCAD SHX Text

NE

AutoCAD SHX Text

SE

AutoCAD SHX Text S

AutoCAD SHX Text W

AutoCAD SHX Text

AutoCAD SHX Text 1/2" = 1'-0"

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text 1'

AutoCAD SHX Text 2'

AutoCAD SHX Text 4'

AutoCAD SHX Text

PARTIAL BUILDING 3 CRAWL SPACE

AutoCAD SHX Text

CHILLED WATER PIPING PLAN

AutoCAD SHX Text B7

63140

183 184

11 159

72 166

164 163

165A

162A

185A

182A

Co Gen

ES001

CLELEH

PROJECT NUMBER

BUILDING NUMBER

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

APPROVED

A

FULLY SPRINKLERED

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASEARCHITECT/ENGINEER OF RECORD

A/E:

STAMP

321 4 5 6 7 8 9 10

HARRELL DESIGN GROUP PC

10720 SIKES PLACE, SUITE 100

CHARLOTTE, NC 28227

704-814-1346 POC: LEE HARRELL PE, LEED AP, QCxP

PRESIDENT

COPYRIGHT © 2024

556-23-104

JULY 26, 2024

CAPTAIN JAMES A. LOVELL FEDERAL HEALTH CARE

CENTER (FHCC)

CHILLED WATER FROM B188 TO B3100% CONSTRUCTION

DOCUMENTS - ISSUED

FOR CONSTRUCTION

HDG PROJECT: 22018Revision Number Revisions: Date:

CONTRACT NO. - 36C25219D0022

TASK ORDER NO. - 36C25223N0287

KEYPLANKEYPLAN

OVERALL ELECTRICAL SITE

PLAN

GENERAL SHEET NOTES

SHEET KEYNOTES

1 75% DD 05/17/2024

2 95% DD 06/18/2024

3 100% CD 07/26/2024

F5

EP103

F5

EP101

E4

EP102

F5

EP104

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text

NW

AutoCAD SHX Text

SW

AutoCAD SHX Text

NE

AutoCAD SHX Text

SE

AutoCAD SHX Text S

AutoCAD SHX Text W

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text

NW

AutoCAD SHX Text

SW

AutoCAD SHX Text

NE

AutoCAD SHX Text

SE

AutoCAD SHX Text S

AutoCAD SHX Text W

AutoCAD SHX Text

AutoCAD SHX Text 50'

AutoCAD SHX Text 100'

AutoCAD SHX Text 200'

AutoCAD SHX Text 1" = 100'"

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

OVERALL SITE PLAN

AutoCAD SHX Text F5

AutoCAD SHX Text A. VOLTAGE DROP SHALL NOT EXCEED VA DESIGN MANUAL VOLTAGE DROP SHALL NOT EXCEED VA DESIGN MANUAL GUIDELINES; 3% MAXIMUM ON BRANCH CIRCUITS AND 2% MAXIMUM ON FEEDERS. B. COORDINATE EXACT CONDUIT ROUTING IN THE FIELD COORDINATE EXACT CONDUIT ROUTING IN THE FIELD PRIOR TO ROUGH-IN AND INSTALLATION. PATCH ANY HOLES CREATED IN HORIZONTAL AND VERTICAL SURFACES TO MAINTAIN ANY EXISTING RATINGS. C. PROTECT AND MAINTAIN EXISTING BUILDING GROUNDING PROTECT AND MAINTAIN EXISTING BUILDING GROUNDING SYSTEMS (I.E. GROUND RINGS, RODS, ETC.) OF ALL BUILDINGS IN SCOPE WHEN ENCOUNTERED. D. COORDINATE ALL UNDERGROUND CONSTRUCTION WITH VA COORDINATE ALL UNDERGROUND CONSTRUCTION WITH VA CAMPUS SECURITY. E. DAMAGE TO ANY EXISTING UTILITIES SHALL BE REPAIRED DAMAGE TO ANY EXISTING UTILITIES SHALL BE REPAIRED IN ACCORDANCE WITH THE VA STANDARD CONSTRUCTION SPECIFICATIONS AT NO ADDITIONAL COST.

AutoCAD SHX Text

1. ELECTRICAL CONTRACTOR TO ROUTE BYPASS VALVE ELECTRICAL CONTRACTOR TO ROUTE BYPASS VALVE ELECTRICAL CONDUIT TIGHT TO BOTTOM OF CEILING STRUCTURE TO CHILLED WATER TUNNEL. CONTINUE ELECTRICAL CONDUIT ROUTING TO FOLLOW 6" CHILLED WATER PIPING TO BUILDING 3 CRAWL SPACE.

PROJECT SCOPE

LIMIT

PROJECT SCOPE LIMIT

BUILDING 188

EXISTING STRUCTURE

BUILDING 4

EP101

CLE

PROJECT NUMBER

BUILDING NUMBER

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

APPROVED

A

FULLY SPRINKLERED

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASEARCHITECT/ENGINEER OF RECORD

A/E:

STAMP

321 4 5 6 7 8 9 10

HARRELL DESIGN GROUP PC

10720 SIKES PLACE, SUITE 100

CHARLOTTE, NC 28227

704-814-1346 POC: LEE HARRELL PE, LEED AP, QCxP

PRESIDENT

COPYRIGHT © 2024

556-23-104

JULY 26, 2024

CAPTAIN JAMES A. LOVELL FEDERAL HEALTH CARE

CENTER (FHCC)

CHILLED WATER FROM B188 TO B3100% CONSTRUCTION

DOCUMENTS - ISSUED

FOR CONSTRUCTION

HDG PROJECT: 22018Revision Number Revisions: Date:

CONTRACT NO. - 36C25219D0022

TASK ORDER NO. - 36C25223N0287

KEYPLANKEYPLAN

BUILDING 188 FLOOR PLAN

GENERAL SHEET NOTES

SHEET KEYNOTES #

F5

EL101

75% DD 05/17/2024

95% DD 06/18/2024

100% CD 07/26/2024

1 2

LEH

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text

NW

AutoCAD SHX Text

SW

AutoCAD SHX Text

NE

AutoCAD SHX Text

SE

AutoCAD SHX Text S

AutoCAD SHX Text W

AutoCAD SHX Text

AutoCAD SHX Text 1/16" = 1'-0"

AutoCAD SHX Text 8'

AutoCAD SHX Text 16'

AutoCAD SHX Text 32'

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

BUILDING 188 FLOOR PLAN

AutoCAD SHX Text F5

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text

NW

AutoCAD SHX Text

SW

AutoCAD SHX Text

NE

AutoCAD SHX Text

SE

AutoCAD SHX Text S

AutoCAD SHX Text W

AutoCAD SHX Text

1. ELECTRICAL CONTRACTOR TO DISCONNECT AND REMOVE ELECTRICAL CONTRACTOR TO DISCONNECT AND REMOVE ALL LIGHTING FIXTURES WITHIN THE AREA OF WORK. COORDINATE SHUTDOWN OF EXISTING LIGHT FIXTURE CIRCUIT WITH VA PRIOR TO DEMOLITION. COORDINATE FINAL MOUNTING HEIGHT OF LIGHTING FIXTURE, DURING REINSTALLATION TO EXISTING LIGHTING CIRCUIT SERVING THE AREA. 2. ELECTRICAL CONTRACTOR TO REMOVE WALL MOUNTED ELECTRICAL CONTRACTOR TO REMOVE WALL MOUNTED OSCILLATING FAN. COORDINATE FINAL LOCATION AND MOUNTING HEIGHT OF OSCILLATING FAN DURING REINSTALLATION.

A. VOLTAGE DROP SHALL NOT EXCEED VA DESIGN MANUAL VOLTAGE DROP SHALL NOT EXCEED VA DESIGN MANUAL GUIDELINES; 3% MAXIMUM ON BRANCH CIRCUITS AND 2% MAXIMUM ON FEEDERS.

DEDUCT ALT. 3DEDUCT ALT. 2 DEDUCT ALT. 3

B8

EP102

B8

EP102

BYPASS VALVE

PRESSURE

SENSOR

NOTE: BYPASS VALVE ASSEMBLY SHALL BE USED

IN THE EVENT DEDUCT ALT NO. 1, 2 OR 3 IS TAKEN.

EP102

CLE

PROJECT NUMBER

BUILDING NUMBER

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

APPROVED

A

FULLY SPRINKLERED

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASEARCHITECT/ENGINEER OF RECORD

A/E:

STAMP

321 4 5 6 7 8 9 10

HARRELL DESIGN GROUP PC

10720 SIKES PLACE, SUITE 100

CHARLOTTE, NC 28227

704-814-1346 POC: LEE HARRELL PE, LEED AP, QCxP

PRESIDENT

COPYRIGHT © 2024

556-23-104

JULY 26, 2024

CAPTAIN JAMES A. LOVELL FEDERAL HEALTH CARE

CENTER (FHCC)

CHILLED WATER FROM B188 TO B3100% CONSTRUCTION

DOCUMENTS - ISSUED

FOR CONSTRUCTION

HDG PROJECT: 22018Revision Number Revisions: Date:

CONTRACT NO. - 36C25219D0022

TASK ORDER NO. - 36C25223N0287

KEYPLANKEYPLAN

BUILDING 4 FLOOR PLAN

GENERAL SHEET NOTES

SHEET KEYNOTES #

F4

EP102

1 100% CD 07/26/2024

LEH

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text

NW

AutoCAD SHX Text

SW

AutoCAD SHX Text

NE

AutoCAD SHX Text

SE

AutoCAD SHX Text S

AutoCAD SHX Text W

AutoCAD SHX Text A. NEW CHILLED WATER PIPING SHALL BE ROUTED WITHIN NEW CHILLED WATER PIPING SHALL BE ROUTED WITHIN PIPING TUNNEL, UNLESS NOTED OTHERWISE. B. VOLTAGE DROP SHALL NOT EXCEED VA DESIGN MANUAL VOLTAGE DROP SHALL NOT EXCEED VA DESIGN MANUAL GUIDELINES; 3% MAXIMUM ON BRANCH CIRCUITS AND 2% MAXIMUM ON FEEDERS. C. COORDINATE EXACT ELECTRICAL CONDUIT ROUTING IN COORDINATE EXACT ELECTRICAL CONDUIT ROUTING IN THE FIELD PRIOR TO ROUGH-IN AND INSTALLATION. PATCH ANY HOLES CREATED IN HORIZONTAL AND VERTICAL SURFACES TO MAINTAIN ANY EXISTING RATINGS.

AutoCAD SHX Text

1. ELECTRICAL CONTRACTOR TO ROUTE BYPASS VALVE ELECTRICAL CONTRACTOR TO ROUTE BYPASS VALVE ELECTRICAL CONDUIT TIGHT TO BOTTOM OF CEILING STRUCTURE. CONTINUE ELECTRICAL CONDUIT ROUTING TO FOLLOW 6" CHILLED WATER PIPING TO BUILDING 3 CRAWL SPACE. COORDINATE EXACT CONDUIT ROUTING IN THE FIELD PRIOR TO ROUGH-IN AND INSTALLATION. 2. FOR DEDUCTIVE ALTERNATE NO. 2 SHALL INCLUDE FOR DEDUCTIVE ALTERNATE NO. 2 SHALL INCLUDE DEDUCTIVE ALTERNATE NO. 1 MINUS ALL WORK ASSOCIATED WITH THE TUNNEL FROM BUILDING 5 & 3. IF DEDUCT IS TAKEN INSTALL BYPASS CONTROL VALVE CIRCUIT ON THE MAIN LINE, PER KEYNOTE 3. REFER TO DETAIL B8/EP102 FOR BYPASS VALVE ASSEMBLY DESIGNATED FOR USE IF DEDUCT ALTERNATES ARE TAKEN. 3. FOR DEDUCTIVE ALTERNATE NO. 3 SHALL INCLUDE FOR DEDUCTIVE ALTERNATE NO. 3 SHALL INCLUDE DEDUCTIVE ALTERNATE NO. 2 MINUS ALL WORK ASSOCIATED WITH THE CHILLED PIPING SERVING BUILDING 1. IF DEDUCT IS TAKEN INSTALL BYPASS CONTROL VALVE CIRCUIT ON THE MAIN LINE, PER KEYNOTE 3. REFER TO DETAIL B8/EP102 FOR BYPASS VALVE ASSEMBLY DESIGNATED FOR USE IF DEDUCT ALTERNATES ARE TAKEN. 4. ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL ONE ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL ONE (1) 20A, 120V ELECTRICAL CONNECTION. CIRCUIT MOTOR OPERATED BYPASS CONTROL VALVE TO AN AVAILABLE SPACE IN BUILDING 1 DISTRIBUTION EQUIPMENT, SEE SHEET EP104. COORDINATE EXACT REQUIREMENTS WITH MANUFACTURER AND FINAL LOCATION IN THE FIELD PRIOR TO ROUGH-IN AND INSTALLATION.

AutoCAD SHX Text

AutoCAD SHX Text 1/16" = 1'-0"

AutoCAD SHX Text 8'

AutoCAD SHX Text 16'

AutoCAD SHX Text 32'

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

BUILDING 4 FLOOR PLAN

AutoCAD SHX Text E4

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text

NW

AutoCAD SHX Text

SW

AutoCAD SHX Text

NE

AutoCAD SHX Text

SE

AutoCAD SHX Text S

AutoCAD SHX Text W

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

NONE

AutoCAD SHX Text

DEDUCT ALTERNATE NO. 2 OR 3:

AutoCAD SHX Text

CHILLED WATER PIPING BYPASS

B8

END OF PIPE

TUNNEL.

END OF PIPE

TUNNEL.

EXISTING ACESS.

UNEXCAVATED

UN

EX

CA

VA

TE

D

SERVICE

SR2

UNEXCAVATED

SERVICE

SR1

STAIR 1

SW-B-01

OPEN SPACE

B01

C8

EP103

ELEC.

ROOM

DEDUCT

ALT. 2

DEDUCT

ALT. 1

E8

EP103

BYPASS VALVE

PRESSURE

SENSOR

NOTE: BYPASS VALVE ASSEMBLY SHALL BE USED

IN THE EVENT DEDUCT ALT NO. 1, 2 OR 3 IS TAKEN.

3, 5

EP103

CLELEH

PROJECT NUMBER

BUILDING NUMBER

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

APPROVED

A

FULLY SPRINKLERED

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASEARCHITECT/ENGINEER OF RECORD

A/E:

STAMP

321 4 5 6 7 8 9 10

HARRELL DESIGN GROUP PC

10720 SIKES PLACE, SUITE 100

CHARLOTTE, NC 28227

704-814-1346 POC: LEE HARRELL PE, LEED AP, QCxP

PRESIDENT

COPYRIGHT © 2024

556-23-104

JULY 26, 2024

CAPTAIN JAMES A. LOVELL FEDERAL HEALTH CARE

CENTER (FHCC)

CHILLED WATER FROM B188 TO B3100% CONSTRUCTION

DOCUMENTS - ISSUED

FOR CONSTRUCTION

HDG PROJECT: 22018Revision Number Revisions: Date:

CONTRACT NO. - 36C25219D0022

TASK ORDER NO. - 36C25223N0287

KEYPLANKEYPLAN

BUILDING 3 AND 5 FLOOR PLAN

GENERAL SHEET NOTES

SHEET KEYNOTES 1

F5

EP103

1 100% CD 07/26/2024

BYPASS VALVE

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text

NW

AutoCAD SHX Text

SW

AutoCAD SHX Text

NE

AutoCAD SHX Text

SE

AutoCAD SHX Text S

AutoCAD SHX Text W

AutoCAD SHX Text A. VOLTAGE DROP SHALL NOT EXCEED VA DESIGN MANUAL VOLTAGE DROP SHALL NOT EXCEED VA DESIGN MANUAL GUIDELINES; 3% MAXIMUM ON BRANCH CIRCUITS AND 2% MAXIMUM ON FEEDERS. B. COORDINATE EXACT CONDUIT ROUTING IN THE FIELD PRIOR COORDINATE EXACT CONDUIT ROUTING IN THE FIELD PRIOR TO ROUGH-IN AND INSTALLATION. INSTALL ALL CONDUIT PER VA DESIGN STANDARDS. C. PATCH ANY HOLES CREATED IN HORIZONTAL AND VERTICAL PATCH ANY HOLES CREATED IN HORIZONTAL AND VERTICAL SURFACES TO MAINTAIN ANY EXISTING RATINGS.

AutoCAD SHX Text

1. ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL ONE ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL ONE (1) 20A, 120V ELECTRICAL CONNECTION. CIRCUIT MOTOR OPERATED BYPASS CONTROL VALVE TO AN AVAILABLE SPACE IN BUILDING 1 DISTRIBUTION EQUIPMENT, SEE SHEET EP104. COORDINATE EXACT REQUIREMENTS WITH MANUFACTURER AND FINAL LOCATION IN THE FIELD PRIOR TO ROUGH-IN AND INSTALLATION. 2. CONTRACTOR SHALL ROUTE NEW ELECTRICAL ALONG CONTRACTOR SHALL ROUTE NEW ELECTRICAL ALONG CHS/R PIPING 7'-0" BELOW EXISTING GRADE TO AVOID CONFLICTS WITH EXISTING UNDERGROUND UTILITIES. 3. CONTRACTOR SHALL ROUTE NEW ELECTRICAL ALONG CONTRACTOR SHALL ROUTE NEW ELECTRICAL ALONG CHS/R PIPING BELOW THE CEILING SURFACE. COORDINATE EXACT CONDUIT ROUTING IN THE FIELD PRIOR TO ROUGH-IN AND INSTALLATION. 4. EXISTING EHRM UNDERGROUND CONDUIT. EXISTING EHRM UNDERGROUND CONDUIT. 5. EXISTING TREE. EXISTING TREE. 6. EXISTING EHRM MANHOLE. EXISTING EHRM MANHOLE. 7. FOR DEDUCTIVE ALTERNATE NO. 1: INCLUDES BASE BID FOR DEDUCTIVE ALTERNATE NO. 1: INCLUDES BASE BID MINUS ALL WORK ASSOCIATED WITH BASEMENT OF BUILDING 3. IF DEDUCT IS TAKEN INSTALL BYPASS CONTROL VALVE CIRCUIT IN BUILDING 5 TUNNEL ON THE MAIN LINE BRANCH PIPING, PER SHEET KEYNOTE 1. REFER TO DETAIL E8/EP103 FOR BYPASS VALVE ASSEMBLY DESIGNATED FOR USE IF DEDUCT ALTERNATES ARE TAKEN.

AutoCAD SHX Text

AutoCAD SHX Text 1/16" = 1'-0"

AutoCAD SHX Text 8'

AutoCAD SHX Text 16'

AutoCAD SHX Text 32'

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

BUILDING 3 AND 5 FLOOR PLAN

AutoCAD SHX Text F4

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text

NW

AutoCAD SHX Text

SW

AutoCAD SHX Text

NE

AutoCAD SHX Text

SE

AutoCAD SHX Text S

AutoCAD SHX Text W

AutoCAD SHX Text

AutoCAD SHX Text 1/16" = 1'-0"

AutoCAD SHX Text 8'

AutoCAD SHX Text 16'

AutoCAD SHX Text 32'

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

PARTIAL BUILDING 3 CRAWL SPACE

AutoCAD SHX Text

CHILLED WATER PIPING PLAN

AutoCAD SHX Text C8

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

NONE

AutoCAD SHX Text

DEDUCT ALTERNATE NO. 1:

AutoCAD SHX Text

CHILLED WATER PIPING BYPASS

E8

AHU

ELEC PANELS

EP104

CLE

PROJECT NUMBER

BUILDING NUMBER

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

APPROVED

A

FULLY SPRINKLERED

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASEARCHITECT/ENGINEER OF RECORD

A/E:

STAMP

321 4 5 6 7 8 9 10

HARRELL DESIGN GROUP PC

10720 SIKES PLACE, SUITE 100

CHARLOTTE, NC 28227

704-814-1346 POC: LEE HARRELL PE, LEED AP, QCxP

PRESIDENT

COPYRIGHT © 2024

556-23-104

JULY 26, 2024

CAPTAIN JAMES A. LOVELL FEDERAL HEALTH CARE

CENTER (FHCC)

CHILLED WATER FROM B188 TO B3100% CONSTRUCTION

DOCUMENTS - ISSUED

FOR CONSTRUCTION

HDG PROJECT: 22018Revision Number Revisions: Date:

CONTRACT NO. - 36C25219D0022

TASK ORDER NO. - 36C25223N0287

KEYPLANKEYPLAN

BUILDING 1 FLOOR PLAN

GENERAL SHEET NOTES

SHEET KEYNOTES #

F5

EP104

1 100% CD 07/26/2024

LEH

CONDUIT COLOR CHART & NOTES

2-HOUR RATED PARTITION

WALL RATING LEGEND

AutoCAD SHX Text

PNL 'VA-FREEZER 1ST-2ND FLR'

AutoCAD SHX Text

PNL 'XLS'

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text

NW

AutoCAD SHX Text

SW

AutoCAD SHX Text

NE

AutoCAD SHX Text

SE

AutoCAD SHX Text S

AutoCAD SHX Text W

AutoCAD SHX Text A. VOLTAGE DROP SHALL NOT EXCEED VA DESIGN MANUAL VOLTAGE DROP SHALL NOT EXCEED VA DESIGN MANUAL GUIDELINES; 3% MAXIMUM ON BRANCH CIRCUITS AND 2% MAXIMUM ON FEEDERS. B. COORDINATE EXACT CONDUIT ROUTING IN THE FIELD PRIOR COORDINATE EXACT CONDUIT ROUTING IN THE FIELD PRIOR TO ROUGH-IN AND INSTALLATION. CONDUIT TYPES AND INSTALLATION METHODS PER VA DESIGN STANDARDS. C. PATCH ANY HOLES CREATED IN HORIZONTAL AND VERTICAL PATCH ANY HOLES CREATED IN HORIZONTAL AND VERTICAL SURFACES TO MAINTAIN ANY EXISTING RATINGS.

AutoCAD SHX Text

AutoCAD SHX Text 1/16" = 1'-0"

AutoCAD SHX Text 8'

AutoCAD SHX Text 16'

AutoCAD SHX Text 32'

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

BUILDING 1 FLOOR PLAN

AutoCAD SHX Text F5

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text

NW

AutoCAD SHX Text

SW

AutoCAD SHX Text

NE

AutoCAD SHX Text

SE

AutoCAD SHX Text S

AutoCAD SHX Text W

AutoCAD SHX Text

1. ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL 20A, ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL 20A, 120V, SINGLE PHASE CIRCUIT BREAKER FOR A BYPASS CONTROL VALVE TO BUILDING 1 PANEL "VA-FREEZER 1ST-2ND FLR". SEE PANEL SCHEDULE THIS SHEET. 2. ELECTRICAL CONTRACTOR TO ROUTE NEW ELECTRICAL ELECTRICAL CONTRACTOR TO ROUTE NEW ELECTRICAL CONDUIT ABOVE THE CEILING. PRESERVE ALL CEILING MOUNTED LIGHTING, POWER, AND SYSTEM DEVICES DURING CONSTRUCTION AND REINSTALL ALL WORK. COORDINATE POWER SHUTDOWN WITH VA PRIOR TO DEMOLITION. COORDINATE EXACT ROUTING IN THE FIELD PRIOR TO ROUGH-IN AND INSTALLATION. 3. ELECTRICAL CONTRACTOR TO ROUTE NEW ELECTRICAL ELECTRICAL CONTRACTOR TO ROUTE NEW ELECTRICAL CONDUIT ALONG CEILING STRUCTURE SIMILAR TO OTHER EXISTING CONDUIT IN THIS SPACE. COORDINATE EXACT ROUTING IN THE FIELD PRIOR TO ROUGH-IN AND INSTALLATION. 4. DRILL HOLE IN WALL FOR A MINIMUM 1" CONDUIT. DRILL HOLE IN WALL FOR A MINIMUM 1" CONDUIT. ROUTE ALONG WALL AS SHOWN. 5. ELECTRICAL CONTRACTOR TO COORDINATE, PRIOR TO ELECTRICAL CONTRACTOR TO COORDINATE, PRIOR TO ROUGH-IN AND INSTALLATION, ROUTING OF NEW ELECTRICAL CONDUIT AROUND EXISTING DUCTWORK, IN MECHANICAL ROOM, PRIOR TO ROUTING DOWN TO LEVEL BELOW. CONTINUE ELECTRICAL CONDUIT ROUTING TO FOLLOW 6" CHILLED WATER PIPING TO BUILDING 3 CRAWL SPACE.

AutoCAD SHX Text SYSTEM (APPLICATION) COLOR COLOR 1. FIRE ALARM RED FIRE ALARM RED RED 2. HVAC, CONTROL, BAS BLUE HVAC, CONTROL, BAS BLUE BLUE 3. FIBER OPTIC COMMUNICATIONS ORANGE FIBER OPTIC COMMUNICATIONS ORANGE ORANGE 4. NORMAL POWER GREEN NORMAL POWER GREEN GREEN 5. EMERGENCY POWER, CRITICAL POWER YELLOW EMERGENCY POWER, CRITICAL POWER YELLOW YELLOW 6. SECURITY BLACK SECURITY BLACK BLACK 7. MEDICAL SYSTEMS, NURSE CALL, MED GAS ALARMS PURPLEMEDICAL SYSTEMS, NURSE CALL, MED GAS ALARMS PURPLEPURPLE

ALL CONDUITS ARE TO BE PRE-PAINTED AT THE FACTORY ACCORDING TO THIS LIST. ALL CONDUITS SHALL BE UL APPROVED, FACTORY-POWDER COAT PAINTED, COLORED RIGID METAL CONDUIT (RMC) AND UL APPROVED, FACTORY POLYMER PAINTED, COLORED ELECTRICAL METAL TUBING (EMT)

556-23-104 100% CD Drawings test4
TEST2
AE402 PRINT
556-23-104 100% CD Drawings TEST
556-23-104 100% CD Drawings test
Arch 7-29-2024 print seal
22018 MECHANICAL 7-29-2024
ELECTRICAL SS
EG001-EG001
ES001-ES001
ES001-ES001
EP101-EP101
EP101-EP101
EP102-EP103-EP102
EP102-EP103-EP102
EP102-EP103-EP103
EP102-EP103-EP103
EP104-EP104
EP104-EP104

EE501-EE501

MECHANICAL SS

AE402 PRINT
AE402 PRINT
AE402 PRINT
AE402 PRINT
AE402 PRINT
AE402 PRINT
AE402 PRINT
AE403 PRINT
AE402 PRINT
AE402 PRINT
AE402 PRINT
AE402 PRINT
AE402 PRINT
AE402 PRINT
AE402 PRINT
AE402 PRINT
AE402 PRINT
AE402 PRINT
AE402 PRINT
AE402 PRINT
AE402 PRINT
AE402 PRINT
AE402 PRINT
AE402 PRINT
AE402
AE402

MP101-501 SS

File details come from the government source that posted it. Updated .