S-Sheets.pdf
PDF 1 MB Posted
- Attached to
- Y1PC--Dallas National Cemetery
- Solicitation number
- 36C10F20R0056
About this file
This pre-solicitation notice is for the design-build construction of Phase 4 expansion at the Dallas Fort Worth National Cemetery in Dallas, Texas. The Department of Veterans Affairs seeks to award a 100% Service-Disabled Veteran Owned Small Business set-aside contract valued between $20-50 million to provide additional gravesites, buildings including a new administration building and soil storage building, utilities, roads, parking and other site improvements across approximately 56 acres. Offerors must be general construction companies with an approved NAICS code and bonding capacity. Proposals may include or exclude a Project Labor Agreement. The work must be completed within 900 calendar days of the notice to proceed. The solicitation will be available on June 19, 2020 through the SAM.gov website and amendments will be posted there. A pre-proposal conference will be scheduled.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| ATTACHMENT 2_PAST PERF QUEST 02.docx | DOCX document | |
| P-Sheets.pdf | ||
| LI-Sheets.pdf | ||
| CS-Sheets 3 of 3.pdf | ||
| G-Sheets.pdf | ||
| CD-Sheets.pdf | ||
| A-Sheets.pdf | ||
| E-Sheets.pdf | ||
| CG-Sheets 1 of 2.pdf | ||
| ATTACHMENT 3 - Dallas Pre-Proposal Inquiry (PPI) Form.docx | DOCX document | |
| B-Sheets.pdf | ||
| DALLAS WAGE RATES.pdf | ||
| I-Sheets.pdf | ||
| 36C10F20R0056_3.docx | DOCX document | |
| F-Sheets.pdf | ||
| Base Bid Specification Package.pdf |
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TABLE: MIN. LAP, LENGTH & STD.
HOOK FOR VERT. & HORIZ. BARS FOR CONCRETE
LENGTH
MIN. LAP
STD. HOOKBARS
10"
1'-0" 11"
1'-6" 1'-4" 1'-2"
4'-3" 3'-0" 2'-6"
6'-4" 5'-8" 5'-0"
#5
#7 #6
#10 #9 #8
#5
CORNER BARS TO
MATCH HORIZ. REINF.
MIN. LAP
RE: TABLE
TYPICAL CORNER
#5
TYPICAL INTERSECTION
STD HOOK
ST
D H
O O
K
GRADE BEAM (REINF. NOT
SHOWN FOR CLARITY)
18"Ø DRILLED PIER
INSTALLATION OF DRILLED PIERS SHALL BE
OBSERVED BY A LICENSED TEXAS
GEOTECHNICAL PROFESSIONAL ENGINEER.
DEPTH OF DRILLED PIER SHALL BE
DETERMINED BY THE GEOTECHNICAL
ENGINEER.
'-0
M
IN
GRAY SHALE
9' -0
M
IN
#3 TIES @ 12"O.C.
5- #8 VERT
EXTEND REINF. TERMINATE
W/ STD. HOOK
PILASTER (REINF. NOT
SHOWN FOR CLARITY)
~EXTEND 6'-0" INTO
DRILLED PIER BELOW
36"Ø DRILLED PIER
'-0
M
IN
GRAY SHALE
9' -0
M
IN
#3 TIES @ 12"O.C.
10- #9 VERT
1' -0
EDGE
NOTE: WELDS BASED ON 36" WIDE PANEL
ROOF:
1 1/2"x20ga. METAL DECKING
MIN. PROPERTIES PER FT OF WIDTH:
I+ = .201 IN4
I- = .222 IN4
S+ = .234 IN3
S- = .247 IN3
JOINT INTERMEDIATE
TRUSSTRUSS
#12 TEK SCREWS
@12"O.C.
SIDE LAPS:
#10 TEK SCREWS
@12"O.C.
#12 TEK SCREWS
~5 PER PANEL
#10 TEK SCREWS
@12"O.C.
CLOSURE
#12 TEK SCREWS
~5 PER PANELSILL BOLTING PER
SCHEDULE
BOUNDARY FASTENERS,
PER SCHEDULE, TYP.
STAGGER HORIZONTAL
PANEL JOINTS
VERTICAL PANEL JOINTS,
CENTER ON STUDS, TYP.
EDGE FASTENERS, PER
SCHEDULE, TYP.
BOUNDARY FASTENERS,
PER SCHEDULE, TYP.
16GA. TRACK
TOP OF FDN.
EDGE FASTENERS, PER
SCHEDULE, TYP.
BOUNDARY FASTENERS,
PER SCHEDULE, TYP.
FIELD FASTENERS,
PER SCHEDULE, TYP.
BLOCKING, CENTER
ON PANEL JOINTS, AS
REQUIRED
PANEL
THICKNESS
(in)
1/2
PLY
SCREW
SIZE
#10 6"O.C.
BOUNDARY EDGE
6"O.C.
FIELD
12"O.C.
SILL BOLTING
TO CONCRETE
1/2"Ø @32"O.C.
EMBED 6"
NOTES:
USE SELF DRILLING TEK SCREWS.
BLOCK ALL PANEL EDGES.
1.
2.
I
MARK
FASTENER SCHEDULE
6"x16ga. TRACK CUT BOTH
FLANGES EACH END, BEND 90°
& SCREW TO STUD FLANGE &
STRAP BRIDGING AS SHOWN
2"x20ga. FLAT CONT.
STRAP BRIDGING BOTH
FACES @ 4'-0"O.C. MAX.
W/ 1- #8 SCREW EACH
FLANGE
6"x16ga. TRACK AT
EVERY FOURTH STUD
AT EACH BRIDGING
LOCATION. REFER TO
DETAIL.
DETAIL
N.T.S.
A
8"
2" C
LR
.#5 @ 12"O.C. EA. WAY,
COORDINATE PLAN SIZE OF PAD WITH
MECHANICAL UNIT SUBMITTAL
3"
3/4" CHAMFER
(TYP.)
6. DO NOT USE ADMIXTURES AND COLORS (EXCEPT AS NOTED HEREIN)
UNLESS SUBSTANTIATING DATA IS SUBMITTED TO AND ACCEPTED
BY THE ENGINEER AND ARCHITECT.
7. PROVIDE 3/4" CHAMFER ON ALL EXPOSED EDGES.
8. FORM REMOVAL.
REMOVE FORMS IN ACCORDANCE WITH THE FOLLOWING SCHEDULE"
A. SIDE FORMS OF GRADE BEAMS.
B. FOUNDATION WALLS: 3 DAYS
9. SLEEVE PLUMBING OPENINGS IN SLABS BEFORE PLACING CONCRETE
AND BENDING REINFORCING STEEL AROUND SLEEVES.
10. REINFORCING STEEL SHALL BE CONTINUOUS THROUGH
ALL CONSTRUCTION JOINTS U.N.O..
11. TESTING LABORATORY SHALL PROVIDE:
A. BATCH PLANT INSPECTION.
B. CONTINUOUS PLACEMENT INSPECTION.
C. CYLINDER TESTS.
COPIES OF ALL TESTS AND INSPECTION SHALL BE SENT IMMEDIATELY
TO THE ENGINEER FOR HIS REVIEW.
12. EPOXY ADHESIVE SHALL BE HILTI HIT HY200.
9. WELDING OF REINFORCING SHALL NOT BE DONE EXCEPT AS SPECIFICALLY
REINFORCING STEEL
DETAILED ON THESE DRAWINGS. WELDED REINFORCEMENT SHALL CONFORM TO ASTM A706.
SPECIAL INSPECTION REQUIRED.
1. DESIGN, FABRICATION AND ERECTION SHALL CONFORM TO "MANUAL OF
STEEL CONSTRUCTION, NINTH EDITION", AS PUBLISHED BY THE AMERICAN
INSTITUTE OF STEEL CONSTRUCTION.
CONCRETE
CONTRACTOR NOTES
5. THIS FIRM DOES NOT PRACTICE OR CONSULT IN THE FIELD OF SAFETY
ENGINEERING. WE DO NOT DIRECT THE CONTRACTOR'S OPERATIONS, AND WE
CANNOT BE RESPONSIBLE FOR THE SAFETY OF PERSONNEL ON THE SITE. SAFETY
IS THE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR SHALL NOTIFY
THE OWNER IF HE CONSIDERS ANY OF THE RECOMMENDED ACTIONS PRESENTED
HEREIN TO BE UNSAFE.
6. THE CONTRACTOR SHALL CONFORM TO ALL SAFETY ORDINANCES, RULES, AND
CODES. OBSERVATION VISITS TO THE SITE BY THE STRUCTURAL ENGINEER SHALL NOT
INCLUDE INSPECTION OF SAFETY ITEMS.
7. UNLESS OTHERWISE SHOWN OR NOTED, ALL PHASES OF WORK ARE TO CONFORM
TO THE MINIMUM STANDARDS OF THE CODES AND SPECIFICATIONS REFERENCED
HEREIN. WHERE CONFLICT BETWEEN CODES AND SPECIFICATIONS OCCUR , THE
MOST STRINGENT REQUIREMENTS SHALL GOVERN.
1. THE CONTRACTOR SHALL VERIFY AND COORDINATE ALL DIMENSIONS
AND ELEVATIONS ON ALL DRAWINGS PRIOR TO STARTING WORK AND
SHALL NOTIFY THE ARCHITECT AND ENGINEER IMMEDIATELY OF ANY
DISCREPANCIES OR INCONSISTENCIES PRIOR TO PROCEEDING.
STRUCTURAL STEEL DESIGN CRITERIA
GENERAL STRUCTURAL NOTES
CODES:
S =.095g S =.052g F = 1.60 F = 2.40 S = .152g S = .124g S = .101g S = .083g a v
MS
M1
10. ALL REINFORCING SHALL BE CONTINUOUS ACROSS CONST. JOINTS, U.N.O..
1. ALL CONCRETE WORK SHALL CONFORM TO ACI 318-14 "BUILDING
CODE REQUIREMENTS FOR STRUCTURAL CONCRETE", AND
ACI 301 "SPECIFICATIONS FOR STRUCTURAL BUILDINGS," EXCEPT
AS MODIFIED BY THE SUPPLEMENTAL REQUIREMENTS CONTAINED
HEREIN OR SHOWN ON THE DRAWINGS.
1. FABRICATE AND PLACE REINFORCING BARS IN ACCORDANCE WITH
CRSI "MANUAL OF STANDARD PRACTICE" AND CRSI "RECOMMENDED
PRACTICE FOR PLACING REINFORCING BARS", AND ACI 318.
2. REINFORCING STEEL TO COMPLY WITH ASTM A615, GRADE 60.
3. WELDED WIRE MESH SHALL CONFORM TO ASTM A185.
4. LAP REINFORCING STEEL IN CONCRETE AS SPECIFIED IN DETAIL
1/S-001.
6. PROVIDE REINFORCING STEEL WITH THE FOLLOWING MINIMUM
PROTECTIVE COVERING OF CONCRETE:
FOOTINGS
EXPOSED TO EARTH OR WEATHER = 2"
CAST AGAINST EARTH = 3"
7. DO NOT USE BRICK OR POROUS MATERIAL TO SUPPORT REINF.
STEEL OFF THE GROUND.
8. SUBMIT SHOP DRAWINGS.
2. SEE ARCHITECTURAL DRAWINGS FOR THE LOCATION OF
ARCHITECTURAL FINISHES.
3. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH
AT 28 DAYS OF 3,000 PSI.
4. CEMENT SHALL CONFORM TO ASTM C 150, TYPE II; AGGREGATES
ASTM C 33.
5. WATER / CEMENT RATIO SHALL BE LESS THAN OR EQUAL TO 0.50.
3. WIND - 115 MPH EXP. C
1. 2015 IBC
2. SEISMIC:
4. DESIGN LOADS:
FLOOR LIVE LOAD = 100psf ROOF LIVE LOAD = 20psf
2. REFERENCE ARCHITECTURAL, CIVIL, MECHANICAL, AND ELECTRICAL
DRAWINGS FOR THE FOLLOWING:
A. SIZE AND LOCATIONS OF ALL OPENINGS
B. SIZE AND LOCATIONS OF ALL NON-BEARING PARTITIONS
C. SIZE AND LOCATION OF ALL CONCRETE CURBS, WALKS, ROOF
AND FLOOR DRAINS, SLOPES, DEPRESSED SLAB AREAS, ETC.
D. FLOOR AND ROOF FINISHES
3. WHERE NO CONSTRUCTION DETAILS ARE SHOWN OR NOTED FOR ANY
PART OF THE WORK, THE DETAILS SHALL BE THE SAME AS FOR
OTHER SIMILAR WORK.
4. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT
LIFE AND THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES SHALL
INCLUDE BUT NOT BE LIMITED TO BRACING AND SHORING OF LOADS DUE TO
CONSTRUCTION, EQUIPMENT, WIND, SEISMIC, ETC.
2. QUALIFIED AND CERTIFIED WELDERS TO BE USED FOR ALL WELDING.
WELDING TO BE PERFORMED IN THE SHOP OF A CERTIFIED FABRICATOR.
ALL WELDING TO CONFORM TO THE LATEST EDITION OF THE AMERICAN
WELDING SOCIETY STRUCTURAL WELDING CODE D1.1.
3. MATERIALS:
WIDE FLANGE SECTIONS: ASTM A992
OTHER ROLLED STRUCTURAL STEEL SHAPES AND PLATES: ASTM A36 U.N.O.
CONTINUITY PLATES IN MOMENT CONNECTIONS: ASTM A572 GRADE 50
STRUCTURAL STEEL TUBES: ASTM A500, GRADE B
STRUCTURAL STEEL PIPE: ASTM A53 TYPE E, GRADE B
WELDING ELECTRODES: ASTM A5.1 OR A5.5, E70-XX ELECTRODE
NUTS AND BOLTS: ASTM A325N
HEADED ANCHOR BOLTS: ASTM F1554, GRADE 55
RUST-INHIBITING PRIMER: TT-P-31
4. CONTRACTOR SHALL INSTALL AND MAINTAIN ADEQUATE BRACING AND
SHORING UNTIL PERMANENT CONNECTIONS TO THE STRUCTURE ARE
EFFECTIVE.
5. SUBMIT SHOP DRAWINGS.
S
DS
D1
SITE CLASS D
RISK CATEGORY II
SEISMIC USE GROUP 1
SEISMIC DESIGN GROUP B
APPROVED DRAWING TITLE
DATE
LOCATION
CHECKED PROJECT NUMBER
DRAWING NUMBER
DESCRIPTION DATE
DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:
C
Office of Construction and Facilities Management
1 3 4 5 6
B
A
D
E
C
B
A
D
E
BUILDING NUMBER
DRAWN
SEAL:
MARK
DALLAS, TEXAS
DALLAS - FORT WORTH
NATIONAL CEMETERY
Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying
Calibre Engineering, Inc.
BID DOCUMENTS
PHASE 4 DEVELOPMENT
916CM2012
OF 246
Cemetery Expertise:
MKEC Engineering Ken Kallenbach
(316) 684-9600
Architect:
TK Architecture Tom Kapels
(719) 325-9303
Irrigation:
Aqua Engineering Bob Beccard
(970) 372-6104
RCDD:
APOGEE Consulting Jim Ezekiel
(919) 535-3878
MEP:
Miller Remick MEP Tom Chapman
(856) 429-4000
Cost Estimating:
MOCA Cost Engineering Todd Waddle
(850) 389-8131
Surveying, Water Wells & Treatment:
Fabre Engineering & Surveying Frank Fabre
(850) 433-6438
Geotechnical Engineering:
Terracon Consultants Jennifer Peters
(210) 907-7648
GENERAL STRUCTURAL
NOTES & DETAILS
03-31-2020 JJB GR
S-001
Scale: 1/2" = 1'-0"1 AND CORNERS OF GRADE BEAMS
TYP. REINF. AT INTERSECTIONS
Scale: 3/4" = 1'-0"2 TYPICAL DRILLED PIER
WOOD
1. LOAD-BEARING STRUCTURAL TIMBER DESIGN AND INSTALLATION SHALL CONFORM TO THE
PROVISIONS AND REQUIREMENTS OF THE IBC AND NDS.
2. SAWN LUMBER USED FOR STRUCTURAL PURPOSES SHALL BE SOLID, S4S STANDARD
NOMINAL SIZE, AND SHALL BE IDENTIFIED BY THE GRADE MARK OF, OR CERTIFICATE OF
INSPECTION ISSUED BY, A LUMBER GRADING OR INSPECTION BUREAU OR AGENCY
RECOGNIZED AS BEING COMPETENT.
3. UNLESS OTHERWISE NOTED, LUMBER SHALL BE USED AT OR BELOW A MOISTURE
CONTENT OF 19%.
4. SAWN LUMBER SHALL BE DOUGLAS FIR-LARCH, VISUALLY GRADED CONFORMING TO THE
FOLLOWING GRADES:
POSTS................................................................................................................SELECT STRUCTURAL HEADERS, JOISTS, RAFTERS, OVERFRAMING, BEAMS & PLATES.......................NO. 1 & BETTER STUDS & TRIMMERS....................................................................................................NO. 2 & BETTER SILLS AND OTHER MEMBERS..........................................................................STANDARD & BETTER
5. EACH PLYWOOD PANEL SHALL BEAR THE TRADEMARK OF THE AMERICAN PLYWOOD
ASSOCIATION. ALL GRADING AND INSTALLATION SHALL CONFORM TO PS 1 OR PS 2. USE
THICKNESS AND FASTENING AS SHOWN ON THE DRAWINGS. SHEATHING SHALL HAVE AN
EXPOSURE RATING AS APPROPRIATE PER THE CONTRACTOR'S CONSTRUCTION SCHEDULE
AND WEATHER CONDITIONS AS SPECIFIED BY THE CONTRACTOR.
6. FOR SHEATHING, PROVIDE: LUMBER BLOCKING, PANEL EDGE CLIPS (ONE MIDWAY
BETWEEN EACH SUPPORT), TONGUE-AND-GROOVE PANEL EDGES, OR OTHER APPROVED
TYPE OF EDGE SUPPORT.
7. WALL DIAPHRAGMS: 1/2" APA RATED WALL SHEATHING. STRUCT I. RE: 3/S-001 FOR NAILING.
8. UNLESS OTHERWISE NOTED OR SHOWN, STRUCTURAL MEMBERS SHALL BE FASTENED
ACCORDING TO IBC TABLE 23O4.9.1 FASTENING SCHEDULE. USE COMMON NAILS.
9. FRAMING CONNECTORS, WHEN USED, SHALL BE MANUFACTURED BY SIMPSON STRONG-TIE
COMPANY, INC. OTHER ICBO APPROVED MANUFACTURERS MAY BE APPROVED BY THE
ENGINEER WHEN SUBMITTED IN WRITING BY THE CONTRACTOR. FRAMING CONNECTORS
IDENTIFIED ON THE DRAWINGS USE SIMPSON DESIGNATIONS.
10. FRAMING CONNECTORS SHALL BE INSTALLED ACCORDING TO THE MANUFACTURER'S
INSTRUCTIONS AND RECOMMENDATIONS.
11. BOLTS, IN WOOD, IF USED, SHALL BE NOT LESS THAN SEVEN DIAMETERS FROM THE END
AND FOUR DIAMETERS FROM THE EDGE OF MEMBERS BEING JOINED.
12. ALL BOLTS SHALL BE RETIGHTENED PRIOR TO THE APPLICATION OF DRYWALL,
SHEATHING, ETC.
13. STRUCTURAL MEMBERS SHALL NOT BE CUT, BORED OR NOTCHED IN EXCESS OF THE
LIMITATIONS SPECIFIED IN NDS, UNLESS OTHERWISE NOTED OR SHOWN.
14. USE COMMON NAILS. SINKER AND BOX NAILS SHALL NOT BE ALLOWED.
15. SHEATHING SHALL BE PROTECTED FROM DAMAGE CAUSED BY THE ELEMENTS OF
WEATHER AT ALL TIMES DURING CONSTRUCTION. PANELS DAMAGED BY WATER OR OTHER
MEANS SHALL BE REPLACED. ROOF SHEATHING LAID EACH DAY SHALL BE COVERED WITH
ROOFING FELT AT THE END OF EACH DAY.
16. PRESERVATIVE TREAT WOOD IN CONTACT WITH CONCRETE.
FOUNDATIONS
1. FOUNDATIONS WERE DESIGNED IN ACCORDANCE WITH THE
GEOTECHNICAL ENGINEERING REPORT PREPARED BY TERRACON
CONSULTANTS, INC., PROJECT #9418P078 DATED NOV 29, 2018.
2. DRILLED PIERS:
MAX. ALLOWABLE END BEARING PRESSURE = 13,500 PSF
MAX. ALLOWABLE SIDE SHEAR = 2,000 PSF
3. HOLES SHALL BE CASED, IF REQUIRED. IF WATER IS ENCOUNTERED
IN THE HOLES, THE CONCRETE SHALL BE PLACED BY USE OF THE
TREMIE TUBE METHOD TO AVOID SEPARATION OF AGGREGATE.
4. INSTALLATION OF DRILLED PIERS SHALL BE OBSERVED BY A
REPRESENTATIVE OF TERRACON CONSULTANTS, INC., WORK SHALL
BE IN ACCORDANCE WITH THE REPORT.
5. REFER TO THE REPORT FOR COMPACTION REQUIREMENTS,
FIELD OBSERVATIONS, TESTING AND OTHER RECOMMENDATIONS.
Scale: NTS4 TYPICAL DECK FASTENERS & SHAPE Scale: NTS3 TYPICAL SHEAR WALL FASTENING
1. THE CONTRACTOR SHALL SUBMIT STRUCTURAL CALCULATIONS AND SHOP
DRAWINGS FOR ALL WALL AND JOIST FRAMING AND CONNECTIONS TO THE
STRUCTURE TO THE ENGINEER OF RECORD FOR REVIEW AND APPROVAL
PRIOR TO FABRICATION. DESIGN SHALL BE IN ACCORDANCE WITH DESIGN
CRITERIA (CODES AND LOADING) AS NOTED UNDER DESIGN CRITERIA THIS
SHEET. WALL DEFLECTION SHALL BE LIMITED TO L/360.
2. ALL METAL STUDS AND JOISTS SHALL BE 16 GAGE C CHANNELS WITH A MINIMUM
FLANGE WIDTH OF 1 5/8". RETURN OF 1/2" DEPTH, U.N.O. STUDS COMPRISING
HEADERS SHALL BE 12 GAGE. RE: DETAIL A THIS SHEET.
3. STUDS AND JOISTS FOR 16ga. AND THICKER SHALL CONFORM TO ASTM A653
GRADE 50 AND HAVE A MINIMUM YIELD STRENGTH OF 50,000 PSI.
4. BRIDGING AND OTHER ACCESSORIES SHALL BE IN ACCORDANCE WITH THE
MANUFACTURER'S RECOMMENDATIONS.
5. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECT
SPECIFICATIONS.
6. RE: DETAIL A THIS DRAWING FOR BRIDGING DETAILS.
1. ALL SCREWS SHALL BE SELF TAPPING, SELF DRILLING UNLESS NOTED
OTHERWISE.
2. WAFER HEAD SCREWS SHALL BE USED WHERE SHEATHING OVERLAYS SCREW.
FASTENERS AND SCREWS (CFSF)
COLD FORMED STEEL FRAMING (CFSF)
- EXTERIOR WALLS & INTERIOR SHEAR WALLS
ADMINISTRATION BUILDING SOIL STORAGE BUILDING
Scale: NTS5 MECHANICAL CONCRETE PAD
HSS4x 4x
3 8~
TYP
SB101
H G F E D C B
A
10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0"
'-0
'-0
'-0
'-0
'-0
25'-0"
SB101
1'-6" (TYP)1'-6" (TYP)
#8 @ 12"O.C. (TOP)
#8 @ 12"O.C. (BOT)
#5
2"
O .C
TO
P) #5
2" O
.C
BO
T)
I
"Ø D
RILL
ED PIER
RE: 2
/S-00
1 (
TYP.)
SB101
SB101
'-0
9"
86'-0"
9" 21'-0"
'-0
9"
9"
'-1 0"
'-1
0"
10" CONCRETE SLAB
OVER 12" VOID FORM
STAGGER REINF. STEEL
INTERIOR SHEAR WALL: 3 5 8"x16ga @16"O.C.
SHEATH THIS EDGE WITH 1/2" PLY.
RE: 3/S-001 FOR FASTENERS
EXTERIOR WALLS: 6"x16ga STUDS @16"O.C.
OUTSIDE EDGE SHALL BE SHEATHED WITH
1/2" PLY. RE: 3/S-001 FOR FASTENERS
DENOTES SHEAR WALL FASTENING
MARK FOR WALL LINE
SB101
21'-3" 21'-3"
SB101
SIM
SIDEWALK
RE: ARCH / CIVIL
6" THICK CONCRETE
STOOP W/ #3 @12"OC
HOLD DOWN 12"
OMIT VOID FORM AT
PIPING LOCATIONS
BAR SPLICES;
WHEN REQUIRED, SPLICE
TOP BARS AT MIDSPAN OF
SLAB AND BOTTOM BARS
OVER GRADE BEAMS
15'-8" 4'-8"
'-8
3'
-4
11'-8"8'-8"
INTERIOR SHEAR WALL: 3 5 8"x16ga @16"O.C.
SHEATH THIS EDGE WITH 1/2" PLY.
RE: 3/S-001 FOR FASTENERS
1 1
1 1
1 DENOTES SIMPSON S/HD85 LIGHT GAGE
HOLDOWN W/ DOUBLE STUD. INSTALL W/
TEK SCREWS TO STUD AND 5 8"Ø HEADED
ANCHOR BOLT IN CONCRETE. EMBED 8"
"Ø
D
RILL
ED PIER
RE: 2
/S-00
1 (
TYP.)
"Ø
D
RILL
ED PIER
RE: 2
/S-00
1 (
TYP.)
#3 DOWELS x 4'-0" @12"O.C.
AT DOOR. EXTEND BARS 1'-6"
INTO GRADE BEAM
#3 DOWELS x 4'-0" @12"O.C.
AT DOOR. EXTEND BARS 1'-6"
INTO GRADE BEAM
#3 DOWELS x 4'-0" @12"O.C.
AT DOOR. EXTEND BARS 1'-6"
INTO GRADE BEAM
2' -6
1'-6"
1 1/2"
CLR.
#5 EACH SIDE
AT MIDHEIGHT
#4 STIRRUPS
@ 8"O.C.
VOID FORM
TERMINATE TOP
BAR W/ 90° STD. HOOK
4-#8
TOP & BOTTOM
2' -6
1'-6"
#4 STIRRUPS
@ 9"O.C.
VOID FORM
5-#8 TOP & BOTTOM
6"x16ga STUDS @16"O.C.
BRICK VENEER
WALL SHEATHING
1 1/2"
COL RE: PLAN
1' -4
8"
1/4
1 1/2"
CLR.
1'-8" SQ.
18"Ø DRILLED PIER
PIER CAP BELOW
3- #4 TIES
@ 6"O.C.
8- #5 VERT
CL PIER
PL3
4x11x0'-11" W/
4-3 4"Ø HEADED ANCHOR
BOLTS~EMBED 12"
T.O. SLAB INSIDE BUILDING
BRICK VENEER
RE: ARCH
2" EXPANSION JOINT
FILLER
PAVEMENT
RE: ARCH
"4"
4"
EXTERIOR
SIDEWALK
AT SIM
#5 EACH SIDE
AT MIDHEIGHT
12ga TRACK W/ 12"Ø ANCHOR
BOLTS @32"O.C.
~EMBED 6"
1' -0
1'
-0
3-#3 TIES @3"O.C.
AROUND ANCHOR BOLTS
APPROVED DRAWING TITLE
DATE
LOCATION
CHECKED PROJECT NUMBER
DRAWING NUMBER
DESCRIPTION DATE
DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:
C
Office of Construction and Facilities Management
1 3 4 5 6
B
A
D
E
C
B
A
D
E
BUILDING NUMBER
DRAWN
SEAL:
MARK
DALLAS, TEXAS
DALLAS - FORT WORTH
NATIONAL CEMETERY
Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying
Calibre Engineering, Inc.
BID DOCUMENTS
PHASE 4 DEVELOPMENT
916CM2012
OF 246
Cemetery Expertise:
MKEC Engineering Ken Kallenbach
(316) 684-9600
Architect:
TK Architecture Tom Kapels
(719) 325-9303
Irrigation:
Aqua Engineering Bob Beccard
(970) 372-6104
RCDD:
APOGEE Consulting Jim Ezekiel
(919) 535-3878
MEP:
Miller Remick MEP Tom Chapman
(856) 429-4000
Cost Estimating:
MOCA Cost Engineering Todd Waddle
(850) 389-8131
Surveying, Water Wells & Treatment:
Fabre Engineering & Surveying Frank Fabre
(850) 433-6438
Geotechnical Engineering:
Terracon Consultants Jennifer Peters
(210) 907-7648
0 2 4 8Scale: 1/4" = 1'-0"1 FOUNDATION PLAN
PL
A
N N
O R
TH
ADMINISTRATION BUILDING
FOUNDATION PLAN
03-31-2020 JJB GR
SB101
NOTES:
1. COORDINATE PLAN WITH ARCH, MECH & PLUMBING PLANS.
Scale: 3/4" = 1'-0"2 SECTION
Scale: 3/4" = 1'-0"4 SECTION
Scale: 3/4" = 1'-0"3 SECTION
A
D
2 4 5 63
B
C
'-0
'-0
7' -4
3'
-4
7' -4
'-0
'-0
91'-0"
1' -0
TY
P.
18'-0" 18'-0" 18'-0" 18'-0" 18'-0"
'-0
"Ø
D
RILL
ED PIER
RE: 2
/S-00
1 (
TYP.)
SB102
SB102
3' -4
1'-0" (TYP.)
'-4
'-4
CORNER PILASTERS
24" SQUARE.
REINF PER 3/SB102
1'-4"x2'-0" PILASTER
~TYP 4 PLACES.
ADJACENT TO GARAGE DOORS.
REINF. PER 3/SB102
DRILLED PIER CENTERLINES
SHALL COINCIDE W/
INSIDE FACE OF WALLS
~TYP
1' -4
6" 6"
#6 @12"O.C. HORIZ.
#6 @12"O.C. VERT.
EL RE: ARCH
DRILLED PIER BEYOND
VOID FORM
DRILLED PIER
FACE OF WALL BEYOND
9" 9"
1'-0"
WALL REINF. NOT
SHOWN FOR CLARITY.
HORIZ. BARS CONT.
THRU PILASTER
4 TIES @ 12"O.C.
8-#10 EXTEND 6'-0"
INTO DRILLED PIER
BELOW
PEMB COLUMN
2'-0"
1' -6
1' -0
(T
YP
1'-0"
CONCRETE PILASTER
6' -0
EL RE: ARCH
PEMB WALL
VERTICAL DOWELS
(SEE ABOVE)
VOID FORM BEYOND
1' -0
PIER REINF NOT
SHOWN FOR CLARITY
3-#3 TIES @3"O.C.
AROUND ANCHOR BOLTS
USE HEADED
ANCHOR BOLTS
ASTM F1554
GRADE 55
1' -0
1'
-0
L2x2x1
4 GALVANIZED
FULL HEIGHT AT EACH
CORNER W/ 12"Ø x 3"
HEADED ANCHOR STUDS
@1'-6"O.C.
0 2 4 8
APPROVED DRAWING TITLE
DATE
LOCATION
CHECKED PROJECT NUMBER
DRAWING NUMBER
DESCRIPTION DATE
DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:
C
Office of Construction and Facilities Management
1 3 4 5 6
B
A
D
E
C
B
A
D
E
BUILDING NUMBER
DRAWN
SEAL:
MARK
DALLAS, TEXAS
DALLAS - FORT WORTH
NATIONAL CEMETERY
Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying
Calibre Engineering, Inc.
BID DOCUMENTS
PHASE 4 DEVELOPMENT
916CM2012
OF 246
Cemetery Expertise:
MKEC Engineering Ken Kallenbach
(316) 684-9600
Architect:
TK Architecture Tom Kapels
(719) 325-9303
Irrigation:
Aqua Engineering Bob Beccard
(970) 372-6104
RCDD:
APOGEE Consulting Jim Ezekiel
(919) 535-3878
MEP:
Miller Remick MEP Tom Chapman
(856) 429-4000
Cost Estimating:
MOCA Cost Engineering Todd Waddle
(850) 389-8131
Surveying, Water Wells & Treatment:
Fabre Engineering & Surveying Frank Fabre
(850) 433-6438
Geotechnical Engineering:
Terracon Consultants Jennifer Peters
(210) 907-7648
Scale: 1/4" = 1'-0"1 FOUNDATION PLAN
PLAN
NORTH
SOIL STORAGE BUILDING
FOUNDATION PLAN
03-31-2020 JJB GR
SB102
Scale: 3/4" = 1'-0"2 SECTION
Scale: 3/4" = 1'-0"3 SECTION
PRE-ENGINEERED METAL BUILDING (PEMB)
1. SUBMIT DRAWINGS AND CALCULATIONS FOR THE PRE-ENGINEERED METAL
BUILDING TO THE ENGINEER FOR APPROVAL. DRAWINGS AND CALCULATIONS
SHALL BE STAMPED BY A LICENSED TEXAS PROFESSIONAL ENGINEER.
2. SUBMIT COLUMN REACTIONS TO THE ENGINEER TO VERIFY STRUCTURAL DESIGN
ON DRAWINGS. DRAWINGS MAY BE ALTERED BASED ON COLUMN REACTIONS
RECEIVED.
3. RE: STRUCTURAL NOTES, DESIGN CRITERIA FOR WIND, SEISMIC, AND ROOF
LOADS. APPLIED LOADS AND LOAD COMBINATIONS SHALL BE IN
ACCORDANCE WITH IBC 2015. LIMIT LATERAL DEFLECTION OF FRAMES VIA WIND
TO .005H AT EAVES.
4. CONTRACTOR SHALL COORDINATE COLUMN AND ANCHOR BOLT SIZES AND
LOCATIONS WITH THE PRE-ENGINEERED METAL BUILDING DRAWINGS. WALL
AND PILASTER SIZES MAY NEED TO BE ALTERED BASED ON DRAWINGS
RECEIVED.
5. RE: PRE-ENGINEERED METAL BUILDING DRAWINGS FOR LOCATION AND SIZE OF
CROSS BRACING IN LONGITUDINAL WALLS.
6. ALL STRUCTURAL STEEL INCLUDING FRAMES, COLUMNS, GIRTS, PURLINS, ETC.
SHALL BE GALVANIZED.
7. RE: SPECIFICATIONS FOR PAINTING REQUIREMENTS AND ADDITIONAL
INFORMATION.
8. EAST BUILDING WALL SHALL BE DESIGNED TO ACCEPT BUILDING EXPANSION IN
FUTURE.
NOTES:
1. COORDINATE PLAN WITH ARCH DRAWINGS.
SF102
6x126x126x126x126x126x12
6x
6x
6x
6x
6x
2x8 @ 24"O.C. (TYP)
2x
4" O
.C
TY
P)
8'-0"
(TYP.)
G T
/ S D
T
HT
HT
HT
HT
SF102
H G F E D C B
A
10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0"
'-0
'-0
'-0
'-0
'-0
2 EQUAL SPACES
4'-0"
8'-0"
(TYP.)
2 EQUAL SPACES
4'-0"
4'-0" 4'-0"
4' -4
4'
-4
SP
AC
ES
6'
-0 "O
C
2'
-0
(J
AC
K
TR
U
SS
ES
SD
T
SD
T
TRUSSES AT 6 EQUAL SPACES
G T
/ S D
T
SD
T
SD
T
SF102
SF102
SF102
4x10
1 1/2"x20ga. METAL DECK, 3 SPAN CONT., (TYP.)
RE: 4/S-001 FOR DECK
FASTENERS AND PROPERTIES
HEADER BELOW
RE: 3/SF102
SHEARWALL
BELOW
ALIGN TRUSS
OVER SHEARWALL
SHEARWALL
BELOW
ALIGN TRUSS
OVER SHEARWALL
SF102
SF102
SF102
2x WOOD DECK TO RAFTERS (TYP.)
2x8 @ 24"O.C. (TYP)
6x
6x
6x12
6x
2x
4" O
.C
TY
P)
2x
4" O
.C
TY
P)
6x6 POST W/BC POST
CAP ABOVE AND BELOW
2x10 AT VALLEYS
(TYP EACH SIDE)
APPROVED DRAWING TITLE
DATE
LOCATION
CHECKED PROJECT NUMBER
DRAWING NUMBER
DESCRIPTION DATE
DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:
C
Office of Construction and Facilities Management
1 3 4 5 6
B
A
D
E
C
B
A
D
E
BUILDING NUMBER
DRAWN
SEAL:
MARK
DALLAS, TEXAS
DALLAS - FORT WORTH
NATIONAL CEMETERY
Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying
Calibre Engineering, Inc.
BID DOCUMENTS
PHASE 4 DEVELOPMENT
916CM2012
OF 246
Cemetery Expertise:
MKEC Engineering Ken Kallenbach
(316) 684-9600
Architect:
TK Architecture Tom Kapels
(719) 325-9303
Irrigation:
Aqua Engineering Bob Beccard
(970) 372-6104
RCDD:
APOGEE Consulting Jim Ezekiel
(919) 535-3878
MEP:
Miller Remick MEP Tom Chapman
(856) 429-4000
Cost Estimating:
MOCA Cost Engineering Todd Waddle
(850) 389-8131
Surveying, Water Wells & Treatment:
Fabre Engineering & Surveying Frank Fabre
(850) 433-6438
Geotechnical Engineering:
Terracon Consultants Jennifer Peters
(210) 907-7648
ADMINISTRATION BUILDING
ROOF FRAMING PLAN
03-31-2020 JJB GR
SF101
NOTES:
1. COORDINATE WITH ARCH ROOF PLAN.
2. GT DENOTES GIRDER TRUSS.
3. HT DENOTES HIP TRUSS.
4. SDT DENOTES STEP DOWN TRUSS.
0 2 4 8Scale: 1/4" = 1'-0"1 ROOF FRAMING PLAN
PL
A
N N
O R
TH
MASONRY VENEER
6" STUDS
12GA. TRACK
LIGHT GAGE
STEEL TRUSSES
RE: PLAN
TRUSS TO GIRDER TRUSS CONN.
BY TRUSS FABRICATOR (TYP.)
METAL DECK
METAL DECK
LIGHT GAGE
STEEL TRUSS
RE: PLAN
Scale: 3/4" = 1'-0"1 SECTION Scale: 3/4" = 1'-0"2 SECTION
GIRDER TRUSS
HSS6x2x1 4 *
12ga BLOCKING
BETWEEN TRUSSES
W/#12 TEK SCREWS
@8"O.C. TO HSS
STAGGERED
6" 1-12
12ga BENT CLOSURE AT EAVE.
ATTACH TO TRUSS
W/2-4-#12 TEK SCREWS
2x FASCIA
RE: ARCH TRUSS TO TUBE CONNECTION
BY TRUSS FABRICATOR SHALL
RESIST UPLIFT AND PROVIDE
LATERAL SUPPORT FOR WALL
* BUTT WELD TUBES (4 SIDES)
AT SPLICES. INSTALL BACKING
BAR AROUND INSIDE PERIMETER
OF TUBE
6" BLOCKING
WALL
SHEATHING
TEK SCREWS TO
BLOCKING
RE: 4/S-001
TRUSS NOTES:
1. TRUSSES SHALL BE DESIGNED FOR THE FOLLOWING APPLIED LOADS IN ADDITION TO THE WEIGHT OF THE TRUSS SYSTEM.
DEAD LOAD: 15 PSF
LIVE LOAD: 20 PSF
BOTTOM CHORD DEAD LOAD = 10 PSF
RE: PLAN FOR MECH. UNIT WEIGHTS AND LOCATIONS.
WIND LOAD:
DESIGN FOR WIND LOAD SHALL BE IN ACCORDANCE WITH ASCE 7-10 AND UFC 3-310-04. APPLICATION OF WIND FORCES SHALL CONSIDER WIND PRESSURES FOR THE MAIN WIND FORCE RESISTING SYSTEMS AND FOR COMPONENTS AND
CLADDING.
2. TRUSSES SHALL BE TEMPORARILY BRACED UNTIL ALL PERMANENT BRACING AND ROOF DECK IS INSTALLED.
3. TRUSSES SHALL BE DESIGNED TO WITHSTAND THE DEAD, LIVE AND WIND LOADS INDICATED. THE CONTRACTOR SHALL BE RESPONSIBLE TO HAVE THE TRUSSES DESIGNED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF TEXAS. ALL DESIGN CALCULATIONS AND DRAWINGS SHALL BE SEALED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF TEXAS. DATA SHALL BE SUBMITTED FOR REVIEW.
4. TRUSS BRACING, BRIDGING, ETC. SHALL BE PROVIDED AS REQUIRED BY THE TRUSS DESIGNER. IN ADDITION, TRUSS BOTTOM CHORDS SHALL BE
BRACED WITH BOTTOM CHORD BRIDGING NOT EXCEEDING 8'-0" ON CENTER.
5. FOR TRUSS DIMENSIONS, ELEVATIONS, ETC., REFER TO RELEVANT STRUCTURAL AND ARCHITECTURAL DETAILS.
6. WEB CONFIGURATIONS SHALL BE DESIGNED BY MFGR. AND COORDINATED WITH ARCHITECTURAL AND MECHANICAL REQUIREMENTS PRIOR TO
FABRICATION.
7. METAL CONNECTORS, WHERE USED, SHALL BE OF SIZE TO FIT MEMBERS AND OF SUFFICIENT STRENGTH TO DEVELOP THE FULL STRENGTH OF THE
SUPPORTED MEMBER, COMPLETE WITH SPECIAL FASTENERS AS REQUIRED.
8. TRUSS DESIGNER SHALL DESIGN STRUCTURAL FASCIA MEMBERS AT CORNERS OF BUILDINGS AS NOTED ON DRAWINGS.
9. TRUSS FABRICATOR SHALL BE RESPONSIBLE FOR PROVIDING PANEL BLOCKING BETWEEN TRUSSES FOR TRANSFER OF DIAPHRAGM SHEAR TO MASONRY BELOW. BLOCKING SHALL BE DESIGNED FOR A LOAD OF 200 POUNDS PER LINEAR FOOT. TRUSS FABRICATOR SHALL PROVIDE
CONNECTIONS BETWEEN PANEL BLOCKING AT EMBED PLATES AT TRUSSES.
LIGHT GAGE STEEL TRUSSES:
1. PROVIDE AND INSTALL ALL MANUFACTURER'S STANDARD STEEL TRUSS COMPONENTS AND
ACCESSORIES AS REQUIRED BY THE MANUFACTURER.
2. FABRICATION SHALL BE PERFORMED BY A COLD-FORMED STEEL TRUSS FABRICATOR
WITH EXPERIENCE DESIGNING AND FABRICATING TRUSS SYSTEMS EQUAL IN MATERIAL,
DESIGN AND EXTENT TO THE SYSTEMS REQUIRED FOR THIS PROJECT.
3. FABRICATE TRUSS FRAMING SYSTEMS AND COMPONENTS OF STRUCTURAL QUALITY STEEL
SHEET IN ACCORDANCE TO ASTM A653 WITH A MINIMUM YIELD STRENGTH OF 50 KSI.
4. BRACING, BRIDGING AND BLOCKING MEMBERS MAY BE FABRICATED OF COMMERCIAL
QUALITY STEEL SHEET IN ACCORDANCE TO ASTM A653 WITH A MINIMUM YIELD STRENGTH
OF 33 KSI.
5. MINIMUM MATERIAL THICKNESS FOR ALL MEMBERS AND COMPONENTS SHALL BE 16 GAGE
UNCOATED THICKNESS.
6. ALL MEMBERS AND COMPONENTS SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM A653,
MINIMUM G60 COATING.
7. WELDING SHALL BE DONE IN ACCORDANCE WITH AWS D1.1, "STRUCTURAL WELDING CODE -
STEEL", AND AWS D1.3, "STRUCTURAL WELDING CODE - SHEET STEEL".
8. WELDERS SHALL BE QUALIFIED IN ACCORDANCE WITH AWS "STANDARD QUALIFICATION
PROCEDURE".
9. VERTICAL DEFLECTION OF TRUSSES SHALL BE LESS THAN OR EQUAL TO 1/240 OF THE SPAN FOR TOTAL LOAD.
10. FRAMING SYSTEMS SHALL BE DESIGNED TO PROVIDE FOR MOVEMENT OF FRAMING MEMBERS
WITHOUT DAMAGE OR OVERSTRESSING, SHEATHING FAILURE, CONNECTION FAILURE, UNDUE
STRAIN ON FASTENERS AND ANCHORS, OR DETRIMENTAL EFFECTS CAUSED BY A MAXIMUM
AMBIENT TEMPERATURE CHANGE OF 153 DEGREES FAHRENHEIT.
11. MEMBERS AND COMPONENTS OF THE TRUSS FRAMING SYSTEMS SHALL BE CUT SQUARELY,
OR AS REQUIRED FOR AN ANGULAR FIT AGAINST ABUTTING MEMBERS.
12. FRAMING MEMBERS SHALL BE HELD POSITIVELY IN PLACE AND PROPERLY FASTENED.
13. ERECTION OF TRUSSES, INCLUDING PROPER HANDLING, SAFETY PRECAUTIONS, TEMPORARY
BRACING AND OTHER SAFEGUARDS AND PROCEDURES ARE THE RESPONSIBILITY OF THE
CONTRACTOR AND THE CONTRACTOR'S INSTALLER.
14. ERECT TRUSSES WITH THE PLANE OF THE WEBS VERTICAL AND PARALLEL TO EACH OTHER
AND ACCURATELY LOCATED AS INDICATED ON THESE DRAWINGS.
15. SUBMIT SHOP DRAWINGS AND CALCULATIONS STAMPED BY A LICENSE TEXAS
PROFESSIONAL ENGINEER FOR APPROVAL PRIOR TO FABRICATION.
TYPICAL END JACK TRUSS
NO SCALE
TYPICAL STEP-DOWN TRUSS
TYPICAL TRUSS
NO SCALE
NO SCALE
STEP DOWN TRUSS RIDGE,
HEIGHT VARIES
FOR TRUSS DETAIL AT
EXTERIOR SUPPORT, REFER TO
PLANS AND DETAILS
F.O. BLDG.
FOR TRUSS DETAIL AT
EXTERIOR SUPPORT, REFER TO
PLANS AND DETAILS
FOR TRUSS DETAIL AT
SUPPORT, REFER TO PLANS
AND DETAILS
F.O. BLDG.
TRUSS GIRDER
F.O. BLDG.
F.O. BLDG. F.O. BLDG.
STEEL BEAM (TYP.)
Scale: 3/4" = 1'-0"5 SECTION Scale: 3/4" = 1'-0"6 SECTION
2x DECKING
RE: SECTION 1 FOR
ITEMS NOT NOTED
2x DECKING
2x RAFTERS
RE: PLAN
COLUMN
CCO COLUMN
CAP
3/16
PLATE
LINE
H2.5 TIE
6" STUDSSLOPE U
HANGER
2x RAFTERS
RE: PLAN
2x10 LEDGER W/
#12 TEK SCREWS @12"O.C.
TOP & BOTTOM (2 ROWS)
TO CLOSURE AND TUBE
12ga BENT CLOSURE AT EAVE.
ATTACH TO EACH TRUSS
W/3"x3"x12ga CLIP ANGLE W/
4-#12 TEK SCREWS EACH LEG
6" CLOSURE
WALL
SHEATHING
#12 TEK SCREWS @8"O.C.
TEK SCREWS TO CLOSURE
RE: 4/S-001
1 1/2x1 1/2x16ga. x5"
LONG CLIP EACH
END W/ 4- #8
SCREWS EACH LEG
FORM HEADER
FROM 2- 6" 12ga.
TRACK AND 2- 8"
12ga. METAL
STUDS W/#8
SCREWS @ 12"O.C.
2"Ø ANCHOR BOLTS
@32"O.C.~EMBED 6"
EL. RE: ARCH.
FORM JAMB FROM
6" 16ga. TRACK AND 2- 6" 16ga. METAL
STUDS
#8 SCREWS
@ 12"O.C.
L4x4x1/4 (LOOSE)
Scale: 1" = 1'-0"3 SECTION
VENEER
PLY. SHEATHING
EN
RE: 3/S-001
FOR FASTENERS 35
8" STUDS
ALIGN TRUSS
OVER WALL
A35 CLIP * (FLAT)
@ 24"O.C. W/
12-#8 TEK SCREWS
3"x3"x12ga CLIP ANGLE W/
3-#10 TEK SCREWS EACH LEG
8" (STUD) BRACE @
4'-0"OC
3-#10 TEK SCREWS
8" STUD @ 4'-0"O.C.
TEK SCREWS
RE: 4/S-001
12ga TRACK
A35 CLIP *
3"x3"x12ga CLIP ANGLE W/
3-#10 TEK SCREWS EACH LEG
* INSTALL W/ 6-#8
TEK SCREWS
EACH LEG
Scale: 3/4" = 1'-0"4 SECTION
METAL DECK
APPROVED DRAWING TITLE
DATE
LOCATION
CHECKED PROJECT NUMBER
DRAWING NUMBER
DESCRIPTION DATE
DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:
C
Office of Construction and Facilities Management
1 3 4 5 6
B
A
D
E
C
B
A
D
E
BUILDING NUMBER
DRAWN
SEAL:
MARK
DALLAS, TEXAS
DALLAS - FORT WORTH
NATIONAL CEMETERY
Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying
Calibre Engineering, Inc.
BID DOCUMENTS
PHASE 4 DEVELOPMENT
916CM2003
OF 246
Cemetery Expertise:
MKEC Engineering Ken Kallenbach
(316) 684-9600
Architect:
TK Architecture Tom Kapels
(719) 325-9303
Irrigation:
Aqua Engineering Bob Beccard
(970) 372-6104
RCDD:
APOGEE Consulting Jim Ezekiel
(919) 535-3878
MEP:
Miller Remick MEP Tom Chapman
(856) 429-4000
Cost Estimating:
MOCA Cost Engineering Todd Waddle
(850) 389-8131
Surveying, Water Wells & Treatment:
Fabre Engineering & Surveying Frank Fabre
(850) 433-6438
Geotechnical Engineering:
Terracon Consultants Jennifer Peters
(210) 907-7648
ADMINISTRATION BUILDING
ROOF TRUSSES AND DETAILS
03-31-2020 JJB GR
SF102
PROJECT NU
916CM2012