LI-Sheets.pdf
PDF 9 MB Posted
- Attached to
- Y1PC--Dallas National Cemetery
- Solicitation number
- 36C10F20R0056
About this file
This pre-solicitation notice is for a design-build construction project to expand the Dallas Fort Worth National Cemetery. The Department of Veterans Affairs will procure Phase 4 expansion as a 100% Service-Disabled Veteran Owned Small Business set-aside, requiring a general construction company with an NAICS code of 236220 and $39.5 million size standard. The project scope includes approximately 56 acres of additional land development with over 12,000 pre-placed crypt gravesites, 600 traditional gravesites, 3,000 in-ground cremains sites, and 300 natural burial sites. Additional site improvements consist of buildings, utilities, roads, parking, and a new irrigation system. The solicitation will be available on June 19, 2020 on beta.SAM.gov, where amendments will also be posted. A pre-proposal conference will be held. Proposals are due approximately 30 days following solicitation posting. The contract is valued between $20-50 million and requires performance and payment bonds with proposals.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| ATTACHMENT 2_PAST PERF QUEST 02.docx | DOCX document | |
| P-Sheets.pdf | ||
| CS-Sheets 3 of 3.pdf | ||
| G-Sheets.pdf | ||
| CD-Sheets.pdf | ||
| A-Sheets.pdf | ||
| E-Sheets.pdf | ||
| CG-Sheets 1 of 2.pdf | ||
| S-Sheets.pdf | ||
| ATTACHMENT 3 - Dallas Pre-Proposal Inquiry (PPI) Form.docx | DOCX document | |
| B-Sheets.pdf | ||
| DALLAS WAGE RATES.pdf | ||
| I-Sheets.pdf | ||
| 36C10F20R0056_3.docx | DOCX document | |
| F-Sheets.pdf | ||
| Base Bid Specification Package.pdf |
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
APPROVED DRAWING TITLE
DATE
LOCATION
CHECKED PROJECT NUMBER
DRAWING NUMBER
DESCRIPTION DATE
DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:
C
Office of Construction and Facilities Management
1 3 4 5 6
B
A
D
E
C
B
A
D
E
BUILDING NUMBER
DRAWN
SEAL:
MARK
DALLAS, TEXAS
916CM2012
DALLAS - FORT WORTH
NATIONAL CEMETERY
Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying
Calibre Engineering, Inc.
Cemetery Expertise:
MKEC Engineering, Inc.
Ken Kallenbach
(316) 684-9600
Architect:
TK-Architecture, LLC Tom Kapels
(719) 325-9303
Irrigation:
Aqua Engineering Bob Beccard
(970) 372-6104
RCDD:
APOGEE Consulting Jim Ezekiel
(919) 535-3878
MEP:
Miller Remick Tom Chapman
(856) 429-4000
Cost Estimating:
MOCA Cost Engineering Todd Waddle
(850) 389-8131
Surveying, Water Wells & Treatment:
Fabre Engineering & Surveying Frank Fabre
(850) 433-6438
Geotechnical Engineering:
Terracon Consultants Jennifer Peters
(210) 907-7648
PHASE 4 DEVELOPMENT
03-31-2020
OF 246
BID DOCUMENTS
LI100
JDL/RWBCCT
ROBERT W. BECCARD
84064P R O F E S S I O N A L E N G I N E E R
S T A T E O F T E X A S
L I C E N S E D
IRRIGATION NOTES AND
LEGEND
IRRIGATION SYSTEM GENERAL DESCRIPTION LEGEND
Q
A-1
2"
A
24 24
B
2 2
.5
GENERAL NOTES
FLAG NOTES
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
TT
ET
CO
CO
CO
CO
CO
CO
I
I
I
W
W
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
OH
E
OH
E
OH
E
OH
E
OH
E
OH
E
OH
E
OH
E
OH
E
OH
E
OH
E
OH
E
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
BE
BE
BE
BE
BE
BE
OH
E
BT
BT
BE
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
OH
E
OH
E
OH
E
OH
E
OH
E
OH
E
OH
E
OH
E
OH
E
OH
E
OH
E
OH
E
OHE
OHE
OHE
OHE
OHE
OHE
OPERATE EXISTING REMOTE CONTROL VALVE FROM
CONTROLLER TO VERIFY OPERATION OF CONTROL
WIRE. REMOVE EXISTING REMOTE CONTROL VALVE
AND REPLACE. RECONNECT EXISTING CONTROL WIRE.
OPERATE EXISTING REMOTE CONTROL VALVE FROM
CONTROLLER TO VERIFY OPERATION OF CONTROL
WIRE. REMOVE EXISTING REMOTE CONTROL VALVE
AND REPLACE. RECONNECT EXISTING CONTROL WIRE.
OPERATE EXISTING REMOTE CONTROL VALVE FROM
CONTROLLER TO VERIFY OPERATION OF CONTROL
WIRE. REMOVE EXISTING REMOTE CONTROL VALVE
AND REPLACE. RECONNECT EXISTING CONTROL WIRE.
ABANDON EXISTING MAINLINE AND
REMOTE CONTROL VALVES IN PLACE.
BRING CONTROL WIRE TO NEW
REMOTE CONTROL VALVES NEXT TO
ADMIN BUILDING.
12"
12"
12"
12"
12"
10" 10"
10"
4"
10"
APPROVED DRAWING TITLE
DATE
LOCATION
CHECKED PROJECT NUMBER
DRAWING NUMBER
DESCRIPTION DATE
DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:
C
Office of Construction and Facilities Management
1 3 4 5 6
B
A
D
E
C
B
A
D
E
BUILDING NUMBER
DRAWN
SEAL:
MARK
DALLAS, TEXAS
916CM2012
DALLAS - FORT WORTH
NATIONAL CEMETERY
Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying
Calibre Engineering, Inc.
Cemetery Expertise:
MKEC Engineering, Inc.
Ken Kallenbach
(316) 684-9600
Architect:
TK-Architecture, LLC Tom Kapels
(719) 325-9303
Irrigation:
Aqua Engineering Bob Beccard
(970) 372-6104
RCDD:
APOGEE Consulting Jim Ezekiel
(919) 535-3878
MEP:
Miller Remick Tom Chapman
(856) 429-4000
Cost Estimating:
MOCA Cost Engineering Todd Waddle
(850) 389-8131
Surveying, Water Wells & Treatment:
Fabre Engineering & Surveying Frank Fabre
(850) 433-6438
Geotechnical Engineering:
Terracon Consultants Jennifer Peters
(210) 907-7648
PHASE 4 DEVELOPMENT
03-31-2020
OF 246
BID DOCUMENTS
LI101
JDL/RWBCCT
ROBERT W. BECCARD
84064P R O F E S S I O N A L E N G I N E E R
S T A T E O F T E X A S
L I C E N S E D
IRRIGATION DEMOLITION
1" =
40' 0' 20' 40' 80'
40'
X X X X X X X X X X X X X X X X X X
X
X
NORTH
VICINITY MAP
SCALE 1"=1000'
MOUNTAIN CREEK PKWY
LO
N
E STAR CIR
R I O
G
RAND DR
ROAD 5
ROAD 4
ROAD 2 ROAD 1
ROAD 1
RO
AD 1
ROAD 3
LI101
TT
O O O O O O OO O O
O
O
FLO
R
AL /
G
R O
U N
D
S PO
LIC
Y
FLO
R
AL /
G
R O
U N
D
S PO
LIC
Y
FL
O
RA
L
GR
OU
ND
S
PO
LI
CY
FL
O
R
AL
G
R O
U N
D S
PO
LI
C Y
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
10"
10"
8"
8"
8"
4"7
2.5"
2"
1.5"
3"
4"
3" 3" 2.5" 2" 1.5"
4"
3" 3" 2.5" 2" 1.5"
4"
3" 3" 2.5" 2" 1.5"
4"
3"
3" 2.5"
2" 1.5"
3"
2.5"
2"
2"
1.25"
1.25"
3"
3" 2.5" 2" 1.5"
3"
3" 2.5" 2" 1.5"
3"
3" 2.5" 2" 1.5"
3"
3" 2.5" 2" 1.5"
3"
3" 2.5" 2" 1.5"
3"
3" 2.5" 2" 1.25"
3"
3" 2.5" 2" 1.5"
3"
2"
1.25"
2.5"
2"
1.25"
3"
3" 2.5" 2" 1.5"
3"
3" 2.5" 2" 1.5"
3" 2.5" 2" 1.25"
2.5"
1.25"
2"
1.25"
1.25"
2.5"
2.5" 2" 1.5"
3"
3"
2.5"
2" 1.25"
2.5" 2" 1.5"
2.5"
2"
1.5"
4"
3"3"2.5"2"1.5"
3"
3"2.5"2"1.5"
4"
3"3"2.5"2"1.5"
4"
3"3" 2.5"2"1.5"
3"
3"2.5"2"1.5"
3"
3"2.5"2"1.5"
3"
2.5"
2"
2"
1.25"
1.25"
3"
3"2.5"2"1.5"
3"
3"2.5"2"1.5"
3"
3"2.5"2"1.25"
3"
3"2.5"2"1.5"
3"
3"2.5"2"1.5"
3"
2.5"2"1.25"
3"
2.5"2"1.5"
3"
3"2.5"2"1.5"
3"
2"
1.25"
2.5"
2"
1.25"
3"
2"1.25" 2.5"
2"
2"
1.25"
4"
4"2.5"
2.5"
2.5"2"
2"1.25"
1.5"
3"
2.5"2"1.5"
4"
4"
4"
4"
4"
4"
3"
3"
3"
3"
8"
Q
Q
Q
Q
Q
Q
Q
Q
Q
Q
Q
Q
24 24
Q
A-1
3"
A-2
3"
A-3
3"
A-4
3"
A-6
2"
A-7
2"
A-8
2"
A-9
2"
A-10
2"
A-11
2"
A-12
2"
A-13
2"
A-15
2"
A-16
2"
A-17
2"
A-18
2"
A-19
2"
A-20
2"
A-21
2"
B-9
A-42
3"
A-41
2"
A-40
3"
A-39
3"
A-37
2"
A-36
2"
A-35
2"
A-34
2"
A-33
2"
A-32
2"
A-31
2"
A-30
2"
A-29
2"
A-28
2"
A-27
2"
A-26
2"
A-24
2"
A-23
3"
A-22
2"
.5
.5
.5 .5
.5
.5 .5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
A-38
1"
A-25
1"
A-14
1"
A-5
1"
.5
.5
.5
.5
1.25"
1.25"
.5
.5
1.25"
1.25"
.5
.5
.5
.5
.5
.5
.5
.5
1.25"
1.25"
.5
.5
.5
.5
.5
1.25"
1.25"
APPROVED DRAWING TITLE
DATE
LOCATION
CHECKED PROJECT NUMBER
DRAWING NUMBER
DESCRIPTION DATE
DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:
C
Office of Construction and Facilities Management
1 3 4 5 6
B
A
D
E
C
B
A
D
E
BUILDING NUMBER
DRAWN
SEAL:
MARK
DALLAS, TEXAS
916CM2012
DALLAS - FORT WORTH
NATIONAL CEMETERY
Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying
Calibre Engineering, Inc.
Cemetery Expertise:
MKEC Engineering, Inc.
Ken Kallenbach
(316) 684-9600
Architect:
TK-Architecture, LLC Tom Kapels
(719) 325-9303
Irrigation:
Aqua Engineering Bob Beccard
(970) 372-6104
RCDD:
APOGEE Consulting Jim Ezekiel
(919) 535-3878
MEP:
Miller Remick Tom Chapman
(856) 429-4000
Cost Estimating:
MOCA Cost Engineering Todd Waddle
(850) 389-8131
Surveying, Water Wells & Treatment:
Fabre Engineering & Surveying Frank Fabre
(850) 433-6438
Geotechnical Engineering:
Terracon Consultants Jennifer Peters
(210) 907-7648
PHASE 4 DEVELOPMENT
03-31-2020
OF 246
BID DOCUMENTS
LI201
JDL/RWBCCT
ROBERT W. BECCARD
84064P R O F E S S I O N A L E N G I N E E R
S T A T E O F T E X A S
L I C E N S E D
IRRIGATION PLAN
1" =
40' 0' 20' 40' 80'
40'
MATCHLINE SEE SHEET LI202
M
AT
C H
LI
N
E
SE
E
SH
EE
T
LI
X X X X X X X X X X X X X X X X X X
X
X
NORTH
VICINITY MAP
SCALE 1"=1000'
MOUNTAIN CREEK PKWY
LO
N
E STAR CIR
R I O
G
RAND DR
ROAD 5
ROAD 4
ROAD 2 ROAD 1
ROAD 1
RO
AD 1
ROAD 3
LI203
LI202
LI201
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
BE
BE
BE
BE
BE
BE
BE
BE
BE
BE
BE
BE
BE
BE
BE
BE
BE
BE
BE
BE
BE
BE
BE
BE
BE
BE
BE
BE
BE
BE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
FLORAL /
GROUNDS POLICY
FLORAL /
GROUNDS POLICY
FLORAL /
GROUNDS POLICY
8"
8"
8"
8"
8"
8"
8"
8"
8"
4"
4"
3"
3"
3"
8"
8"
8"
8"
8"
8"
3"
3"
3"
3" 2.5" 2" 1.5"
3"
3" 2.5" 2" 1.5"
3"
2"
1.25"
2.5" 2"
1.25"
3"
1.25" 3"
2.5"
2"
1.25"
3"
2"
2"
2"
1.25"1.25"
3"
2.5"
2"
1.5"
3"
2.5"
2"
1.25"
3"
2.5"
2"
1.5"
3"
3"
2.5"
2"
3"
2"
2"
2"
1.25"
1.25"
3"
2.5"
2"
1.5"
2.5"
2"
1.5"
2"
1.25"
8"
3" 2.5"
2"
2"1.25"
1.25"
3"
2.5"2"1.5"
3"
3"2.5"2"1.5"
3"
3"
2.5"
3"3"2.5"
3"
4"
2.5"
3"
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
1.25"
2"
4"
4"
3"
3"
2.5"
2"
1.5"
3"
3"
2.5"
2"
1.5"
2.5"
2"
2"
1.25"
2.5"
2"
1.25"
3"
3"
2.5"
2"
1.5"
3"
3"
2.5"
2"
1.5"
Q
Q
Q
Q
Q
A B
Q
Q
B-1
2"
B-2
2"
B-3
2"
B-4
2"
B-14
2"
B-15
2"
B-12
2"
- B-13
2"
B-11
2"
B-9
2"
B-5
2"
B-6
2"
B-7
2"
B-8
2"
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5.5 .5
.5 .5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5 .5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5.5
.5.5
Q
Q
Q
Q
Q
Q
Q
Q
Q
.5
.5
.5
.5
B-17
1.5"
.5
.5
B-16
1"
B-10
2"
Q
Q
Q
.5 .5
.5 .5
.5 .5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5 .5
.5
.5 .5
.5 .5
.5
.5 .5
.5
.5
.5
.5
.5 .5
.5
B-20
3"
B-19
2"
B-18
2"
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
1.25"
1.25"
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
2"
2" 1.5"
1.5"
1.25"
1.25"
.5
.5
.5
.5
.5
.5
.5
1.25"
2" 1.5"
1.5" 1.25"
1.5"
1.5"
1.25"
8"
8"
8" 8" 8"
8"
8"
.5
.5
.5
.5
.5
.5
.5
.5
.5
Q
Q
Q
.5.5
.5
1.25"
APPROVED DRAWING TITLE
DATE
LOCATION
CHECKED PROJECT NUMBER
DRAWING NUMBER
DESCRIPTION DATE
DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:
C
Office of Construction and Facilities Management
1 3 4 5 6
B
A
D
E
C
B
A
D
E
BUILDING NUMBER
DRAWN
SEAL:
MARK
DALLAS, TEXAS
916CM2012
DALLAS - FORT WORTH
NATIONAL CEMETERY
Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying
Calibre Engineering, Inc.
Cemetery Expertise:
MKEC Engineering, Inc.
Ken Kallenbach
(316) 684-9600
Architect:
TK-Architecture, LLC Tom Kapels
(719) 325-9303
Irrigation:
Aqua Engineering Bob Beccard
(970) 372-6104
RCDD:
APOGEE Consulting Jim Ezekiel
(919) 535-3878
MEP:
Miller Remick Tom Chapman
(856) 429-4000
Cost Estimating:
MOCA Cost Engineering Todd Waddle
(850) 389-8131
Surveying, Water Wells & Treatment:
Fabre Engineering & Surveying Frank Fabre
(850) 433-6438
Geotechnical Engineering:
Terracon Consultants Jennifer Peters
(210) 907-7648
PHASE 4 DEVELOPMENT
03-31-2020
OF 246
BID DOCUMENTS
LI202
JDL/RWBCCT
ROBERT W. BECCARD
84064P R O F E S S I O N A L E N G I N E E R
S T A T E O F T E X A S
L I C E N S E D
IRRIGATION PLAN
1" =
40' 0' 20' 40' 80'
40'
MATCHLINE SEE SHEET LI201
X X X X X X X X X X X X X X X X X X
X
X
NORTH
VICINITY MAP
SCALE 1"=1000'
MOUNTAIN CREEK PKWY
LO
N
E STAR CIR
R I O
G
RAND DR
ROAD 5
ROAD 4
ROAD 2 ROAD 1
ROAD 1
RO
AD 1
ROAD 3
LI203
LI202
LI201
M
AT
C
H
LI
N E
SE
E
SH
EE
T
LI
MATCHLINE THIS SHEET
MATCHLINE THIS SHEET
I
I
I
I
I
I
I
I
I
I
I
I
I
I
TT
ET
CO
CO
CO
CO
CO
CO
I
I
I
W
W
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
OH
E
OH
E
OH
E
OH
E
OH
E
OH
E
OH
E
OH
E
OH
E
OHE
OHE
OHE
OHE
OHE
OHE
BE
BE
BE
BE
BE
OH
E
BT
BT
BE
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
BT
OH
E
OH
E
OH
E
OH
E
OH
E
OH
E
OH
E
OH
E
OH
E
OHE
OHE
OHE
OHE
OHE
FLO
RAL /
G R
O U
N D
S PO
LIC
Y
POTHOLE AND LOCATE EXISTING POTABLE WATER MAIN
PRIOR TO INSTALLATION OF IRRIGATION MAINLINE.
DEPTH OF POTABLE WATER MAIN IS NOT KNOWN. INSTALL
IRRIGATION MAINLINE BELOW POTABLE WATER MAIN.
12"
12"
12"
12"
12"
12"
10" 10"
8" 8"
8"
8"
8"
8"
10"
4"
10"
4"
4"
8"
8"
8"
3"
2.5"
2"
1.5"
4"
4"
4" 4"
1.25"
1.25"
3"
3"
2.5"
3"
2.5"
2"
1.5"
2"
1.25"3"
2"
1.25"
2"
1.25"
2"
2"
1.5"
1.25"
1.5"
8"
3"
2.5"
2"
2"
1.5"
1.25"
2.5"
2"
1.25"
3" 2.5"
2"
3"
Q
A B
Q
A-1
3"
A-2
3"
A-3
3"
A-4
3"
A-6
2"
A-7
2"
A-8
2"
A-9
2"
B-24
2"
B-25
2"
B-26
2"
.5
.5
.5
D-30
1.5"
D-21
1.5"
D-22
2"
D-24
2"
D-25
1.5"
D-26
1.5"
D-27
2"
D-28
1"
Q
Q
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
A-5
1"
B-28
1"
B-27
1.5"
Q
Q
.5 .5
.5 .5
.5 .5
.5
.5
B-23
2"
B-22
2"
B-21
2"
.5
.5
.5
Q
2 2
2 2
2"
2"
1.25" 1.25"
1.25"
1.25"
1.5"
1.5"
1.25"
1.25" 1.25"
2.5" 1.25"
1.25"
2.5" 1.25"2"
1.25"
2" 1.5"
1.25" 1.25"
1.5"
1.25"
1.25"
.5
.5
.5
.5
1.25"
.5
.5
2"
.5 .5
.5 .5
.5 .5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5 .5
.5
.5
.5
.5
.5
.5
1.25"
1.25"
D-29
1"
.5 .5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5.5 .5 .5
.5
.5
.5 .5
.5
.5
.5
.5
.5
.5
.5 .5
.5
.5
.5
2"
1.5"
1.25"
D-23
1"
.5 .5
1.25"
.5
.5
1.5"
1.25" 1.25"
3"
3"
2"
2.5"
2"
1.25"
2"
2"
1.25"
APPROVED DRAWING TITLE
DATE
LOCATION
CHECKED PROJECT NUMBER
DRAWING NUMBER
DESCRIPTION DATE
DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:
C
Office of Construction and Facilities Management
1 3 4 5 6
B
A
D
E
C
B
A
D
E
BUILDING NUMBER
DRAWN
SEAL:
MARK
DALLAS, TEXAS
916CM2012
DALLAS - FORT WORTH
NATIONAL CEMETERY
Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying
Calibre Engineering, Inc.
Cemetery Expertise:
MKEC Engineering, Inc.
Ken Kallenbach
(316) 684-9600
Architect:
TK-Architecture, LLC Tom Kapels
(719) 325-9303
Irrigation:
Aqua Engineering Bob Beccard
(970) 372-6104
RCDD:
APOGEE Consulting Jim Ezekiel
(919) 535-3878
MEP:
Miller Remick Tom Chapman
(856) 429-4000
Cost Estimating:
MOCA Cost Engineering Todd Waddle
(850) 389-8131
Surveying, Water Wells & Treatment:
Fabre Engineering & Surveying Frank Fabre
(850) 433-6438
Geotechnical Engineering:
Terracon Consultants Jennifer Peters
(210) 907-7648
PHASE 4 DEVELOPMENT
03-31-2020
OF 246
BID DOCUMENTS
LI203
JDL/RWBCCT
ROBERT W. BECCARD
84064P R O F E S S I O N A L E N G I N E E R
S T A T E O F T E X A S
L I C E N S E D
IRRIGATION PLAN
1" =
40' 0' 20' 40' 80'
40'
M
AT
C H
LI
N
E
SE
E
SH
EE
T
LI
M
AT
C
H
LI
N E
SE
E
SH
EE
T
LI
LI203
LI202
LI201
X X X X X X X X X X X X X X X X X X
X
X
NORTH
VICINITY MAP
SCALE 1"=1000'
MOUNTAIN CREEK PKWY
LO
N
E STAR CIR
R I O
G
RAND DR
ROAD 5
ROAD 4
ROAD 2 ROAD 1
ROAD 1
RO
AD 1
ROAD 3
LOCATION
CHECKED PROJECT NUMBER
DRAWING NUMBER
DESCRIPTION DATE
DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:
C
Office of Construction and Facilities Management
1 3 4 5 6
B
A
D
E
C
B
A
D
E
BUILDING NUMBER
DRAWN
SEAL:
MARK
DALLAS, TEXAS
916CM2012
DALLAS - FORT WORTH
NATIONAL CEMETERY
Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying
Calibre Engineering, Inc.
Cemetery Expertise:
MKEC Engineering, Inc.
Ken Kallenbach
(316) 684-9600
Architect:
TK-Architecture, LLC Tom Kapels
(719) 325-9303
Irrigation:
Aqua Engineering Bob Beccard
(970) 372-6104
RCDD:
APOGEE Consulting Jim Ezekiel
(919) 535-3878
MEP:
Miller Remick Tom Chapman
(856) 429-4000
Cost Estimating:
MOCA Cost Engineering Todd Waddle
(850) 389-8131
Surveying, Water Wells & Treatment:
Fabre Engineering & Surveying Frank Fabre
(850) 433-6438
Geotechnical Engineering:
Terracon Consultants Jennifer Peters
(210) 907-7648
PHASE 4 DEVELOPMENT
03-31-2020
OF 246
BID DOCUMENTS
LI501
JDL/RWBCCT
ROBERT W. BECCARD
84064P R O F E S S I O N A L E N G I N E E R
S T A T E O F T E X A S
L I C E N S E D
IRRIGATION DETAILS
1 AIR/VACUUM RELIEF VALVE
ASSEMBLY N.T.S. 2 ISOLATION GATE VALVE
ASSEMBLY N.T.S. 3 QUICK COUPLER VALVE
ASSEMBLY N.T.S.
Q
4 POP-UP ROTOR SPRINKLER
ASSEMBLY N.T.S. 5 POP-UP SPRAY SPRINKLER
ASSEMBLY N.T.S. 6 REMOTE CONTROL VALVE 3"
ASSEMBLY N.T.S.
LOCATION
CHECKED PROJECT NUMBER
DRAWING NUMBER
DESCRIPTION DATE
DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:
C
Office of Construction and Facilities Management
1 3 4 5 6
B
A
D
E
C
B
A
D
E
BUILDING NUMBER
DRAWN
SEAL:
MARK
DALLAS, TEXAS
916CM2012
DALLAS - FORT WORTH
NATIONAL CEMETERY
Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying
Calibre Engineering, Inc.
Cemetery Expertise:
MKEC Engineering, Inc.
Ken Kallenbach
(316) 684-9600
Architect:
TK-Architecture, LLC Tom Kapels
(719) 325-9303
Irrigation:
Aqua Engineering Bob Beccard
(970) 372-6104
RCDD:
APOGEE Consulting Jim Ezekiel
(919) 535-3878
MEP:
Miller Remick Tom Chapman
(856) 429-4000
Cost Estimating:
MOCA Cost Engineering Todd Waddle
(850) 389-8131
Surveying, Water Wells & Treatment:
Fabre Engineering & Surveying Frank Fabre
(850) 433-6438
Geotechnical Engineering:
Terracon Consultants Jennifer Peters
(210) 907-7648
PHASE 4 DEVELOPMENT
03-31-2020
OF 246
BID DOCUMENTS
LI502
JDL/RWBCCT
ROBERT W. BECCARD
84064P R O F E S S I O N A L E N G I N E E R
S T A T E O F T E X A S
L I C E N S E D
IRRIGATION DETAILS
1 REMOTE CONTROL VALVE
ASSEMBLY N.T.S.
MAINLINE PIPE
REMOTE CONTROL VALVE
ASSEMBLY
SOLVENT
WELD TEE
ISOLATION ANGLE VALVE
ON SERVICE TEE
2 SPRINKLER PLACEMENT
DETAIL N.T.S.
52" MIN.
55.5"
IRRIGATION
AISLE BOUNDARY
8"
4'
LOCATION
CHECKED PROJECT NUMBER
DRAWING NUMBER
DESCRIPTION DATE
DESIGN CONSULTANTS: ARCHITECT / ENGINEER OF RECORD:
C
Office of Construction and Facilities Management
1 3 4 5 6
B
A
D
E
C
B
A
D
E
BUILDING NUMBER
DRAWN
SEAL:
MARK
DALLAS, TEXAS
916CM2012
DALLAS - FORT WORTH
NATIONAL CEMETERY
Calibre 9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com Construction Management Civil Engineering Surveying
Calibre Engineering, Inc.
Cemetery Expertise:
MKEC Engineering, Inc.
Ken Kallenbach
(316) 684-9600
Architect:
TK-Architecture, LLC Tom Kapels
(719) 325-9303
Irrigation:
Aqua Engineering Bob Beccard
(970) 372-6104
RCDD:
APOGEE Consulting Jim Ezekiel
(919) 535-3878
MEP:
Miller Remick Tom Chapman
(856) 429-4000
Cost Estimating:
MOCA Cost Engineering Todd Waddle
(850) 389-8131
Surveying, Water Wells & Treatment:
Fabre Engineering & Surveying Frank Fabre
(850) 433-6438
Geotechnical Engineering:
Terracon Consultants Jennifer Peters
(210) 907-7648
PHASE 4 DEVELOPMENT
03-31-2020
OF 246
BID DOCUMENTS
LI503
JDL/RWBCCT
ROBERT W. BECCARD
84064P R O F E S S I O N A L E N G I N E E R
S T A T E O F T E X A S
L I C E N S E D
IRRIGATION DETAILS
1 FLOWER WATER STATION
ASSEMBLY N.T.S. 2 TRENCH
DETAIL N.T.S. 3 JOINT RESTRAINT FITTINGS
ASSEMBLY N.T.S.
Pipe Fitting with Joint Restraint
11.25° BEND (IPS)
(PJ x PJ)
TEE w/ REDUCER IN
BRANCH & RUN (IPS)
(PJ x PJ x PJ)
45° BEND (IPS)
(PJ x PJ)
22.5° BEND (IPS)
(PJ x PJ)
TEE (IPS)
(PJ x PJ x PJ)
90° BEND (IPS)
(PJ x PJ)
REDUCER (IPS)
(PJ x PJ)
PIPE BELL
PLAN VIEW
A. IRRIGATION CONTROLLER ASSEMBLY
B. UL LISTED 5/8" X 10' COPPER-CLAD GROUNDING
ROD
C. UL LISTED 4" X 8' COPPER GROUNDING PLATE
D. 9" ROUND POLYMER CONCRETE VALVE BOX
AND LID
E. CADWELD CONNECTION: PAIGE ELECTRIC
F. 3" MINIMUM DEPTH OF 3/4" WASHED GRAVEL
G. BRICK (1 OF 4)
H. #6 AWG INSULATED SOLID COPPER WIRE. NO
SHARP BENDS.
I. SPHERE OF INFLUENCE
J. EARTH CONTACT MATERIAL, POWERSET© OR
POWERFILL© DEPENDING ON SOIL CONDITIONS
K. FINISH GRADE
A
C
B
8'
10'
11'
I
I
30" MINIMUM
12"
SECTION VIEW
H
H
H
B
C J
D
G
F
E
NOTES:
1. CONNECT ALL #6 AWG WIRES INSIDE THE
CONTROLLER. CONNECT ONE WIRE TO
THE CONTROLLER GROUND LUG AND
USE A #4 SPLIT BOLT TO CONNECT ALL
WIRES TOGETHER.
2. EARTH CONTACT MATERIAL MUST
COMPLETELY COVER THE WELD JOINT
ON THE GROUND PLATE.
K
4 THRUST BLOCK
DETAIL N.T.S.
5 GROUNDING
DETAIL N.T.S. 6 POP-UP BUBBLER
ASSEMBLY N.T.S.7 IRRIGATION CONTROLLER
ASSEMBLY N.T.S.
UNDISTURBED SOIL
THRUST BLOCK
WIRE
X Y
7 BUBBLER PLACEMENT
DETAIL N.T.S.
File details come from the government source that posted it. Updated .