RTA DRAWINGS VOL2.pdf
PDF 14 MB Posted
- Attached to
- FY21 SOF Combined Squad Ops Facility, Duke Field, FL Federal contract opportunity
- Solicitation number
- W9127821R0006
About this file
This document provides details on a federal contract solicitation for construction services. The U.S. Army Corps of Engineers Engineering District Mobile is seeking proposals to construct a 36,700 square foot two-story operations facility at Duke Field in Florida for approximately $10-25 million. Functional areas for the facility include administration, planning and briefing areas, formal training, secure open storage and planning vault, mobility storage, and aircrew flight equipment storage and maintenance. Interested parties must register in the System for Award Management to access the solicitation documents on beta.sam.gov by the response due date. The solicitation uses best value source selection and has a small business set-aside definition. Questions must be submitted through the ProjNet system. Proposals are due based on the posting date.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| W9127821R0006 JA for Trane HVAC at Combined Squad Ops Facility Duke Field (Final)_Redacted.pdf | ||
| W9127821R0006 AM05 DRAWINGS.pdf | ||
| W9127821R0006 AM05.pdf | ||
| W9127821R0006 AM04.pdf | ||
| W9127821R0006 AM04 DRAWINGS.pdf | ||
| W9127821R0006 AM03.pdf | ||
| W9127821R0006 AM02.pdf | ||
| W9127821R0006 Minutes-Pre-Bid site visit.pdf | ||
| W9127821R0006 AM01.pdf | ||
| VOL2.PDF | ||
| VOL4.PDF | ||
| EM 385-1-1.pdf | ||
| VOL3.PDF | ||
| VOL1.PDF | ||
| RTA DRAWINGS VOL1.pdf |
Show all 15
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
US Army Corps of Engineers®
MOBILE DISTRICT
109 SAINT JOSEPH STREET
MOBILE, AL 36602
FTFA163002 SOF COMBINED SQUAD OPS FACILITY
DUKE FIELD
APRIL 2021
20009 21R
VOLUME 2 OF 2
A
SHEET
IDENTIFICATION
US Army Corps of
Engineers ®
Mobile District
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D E
S
IG
N E
D B
Y
B U
L L
O C
K T
IC
E
A S
S O
C
IA
T E
S
E
C
E R
V A
N T
E S
S T
R E
E T
S
U
IT
E B
P E
N S
A C
O L
A F
L O
R
ID
A
2 3 4 5
B
C
D
D R
A W
N B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
S
U E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
P R
O J E
C T
N U
M B
E R
F
IL
E N
A M
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E x
M O
B
IL
E D
IS
T
R
IC
T
S
A
IN
T J
O S
E P
H S
T R
E E
T
M O
B
IL
E A
L A
B A
M A
F T
F A
S O
F C
O M
B
IN
E D
S Q
U A
D O
P S
F A
C
IL
IT
Y
D
U K
E F
IE
L
D
D U
K E
F
IE
L D
F
L O
R
ID
A
G-002BFTFA 163002
D R
A W
IN
G
I N
D E
X
J G
H
J G
H
R C
R
B T
A
-3
-2
M E
F G
B
.D W
G
W
-2
-R
-0
INDEX OF DRAWINGS - VOLUME I
SHEET
NUMBER SHEET NAME
I-450 INTERIOR DETAILS & FURNITURE SCHEDULE
I-601 FIRST FLOOR FINISH SCHEDULE AND DETAILS
I-602 SECOND FLOOR FINISH SCHEDULE AND KEY
I-603 SIGNAGE SCHEDULE AND SIGN TYPES
INDEX OF DRAWINGS - VOLUME I
SHEET
NUMBER SHEET NAME
S-410 2ND FLOOR SECTIONS
S-411 2ND FLOOR SECTIONS
S-420 LOW ROOF SECTIONS
S-421 LOW ROOF SECTIONS
S-430 ROOF SECTIONS
S-501 TYPICAL FOUNDATION DETAILS
S-502 TYPICAL COLUMN DETAILS
S-503 TYPICAL STEEL DETAILS
S-504 TYPICAL STEEL DETAILS
S-505 TYPICAL STEEL DETAILS
S-601 TYPICAL MASONRY DETAILS
S-700 DUMPSTER ENCLOSURE PLAN AND SECTION
ARCHITECTURAL
A-001 LEGENDS AND ABBREVIATIONS
A-002 INTERIOR METAL STUD WALL TYPES
A-003 INTERIOR CMU AND EXTERIOR WALL TYPES
A-101 OVERALL 1ST FLOOR PLAN
A-102 OVERALL 2ND FLOOR PLAN
A-110 PARTIAL 1ST FLOOR NOTE PLAN - WEST
A-111 PARTIAL 1ST FLOOR NOTE PLAN - EAST
A-112 PARTIAL 2ND FLOOR NOTE PLAN - WEST
A-113 PARTIAL 2ND FLOOR NOTE PLAN - EAST
A-114 PARTIAL 1ST FLOOR DIMENSION PLAN - WEST
A-115 PARTIAL 1ST FLOOR DIMENSION PLAN - EAST
A-116 PARTIAL 2ND FLOOR DIMENSION PLAN - WEST
A-117 PARTIAL 2ND FLOOR DIMENSION PLAN - EAST
A-140 ROOF PLAN
A-141 ROOF DETAILS
A-142 ROOF DETAILS
A-150 PARTIAL 1ST FLOOR CEILING PLAN - WEST
A-151 PARTIAL 1ST FLOOR CEILING PLAN - EAST
A-152 PARTIAL 2ND FLOOR CEILING PLAN - WEST
A-153 PARTIAL 2ND FLOOR CEILING PLAN - EAST
A-201 EXTERIOR ELEVATIONS
A-202 EXTERIOR ELEVATIONS
A-301 BUILDING SECTIONS
A-302 BUILDING SECTIONS
A-310 WALL SECTIONS
A-311 WALL SECTIONS
A-312 WALL SECTIONS
A-320 ELEVATOR SECTION
A-401 ENLARGED PLANS AND ELEVATIONS
A-402 ENLARGED PLANS AND CASEWORK ELEVATIONS
A-403 ENLARGED PLANS AND CASEWORK ELEVATIONS
A-410 ENLARGED STAIR PLANS
A-411 ENLARGED STAIR PLANS AND SECTIONS - LOBBY
A-412 STAIRS - TYPICAL DETAILS
A-413 EQUIPMENT YARD PLANS AND SECTIONS
A-450 LOBBY INTERIOR ELEVATIONS & STAIR DETAILS
A-501 PLAN DETAILS
A-502 PLAN DETAILS
A-503 PLAN AND SECTION DETAILS
A-504 SECTION DETAILS
A-601 DOOR SCHEDULE - 1ST FLOOR
A-602 DOOR SCHEDULE - 2ND FLOOR
A-603 WINDOW ELEVATIONS
A-604 INTERIOR OPENING DETAILS
A-605 EXTERIOR OPENING DETAILS
A-606 EXTERIOR OPENING DETAILS
A-701 CASEWORK SECTIONS
INTERIOR
I-101 FIRST FLOOR FINISH PLAN
I-102 SECOND FLOOR FINISH PLAN
I-103 FIRST FLOOR FURNITURE PLAN
I-104 SECOND FLOOR FURNITURE PLAN
I-105 FIRST FLOOR SIGNAGE AND CORNER GUARD PLAN
I-106 SECOND FLOOR SIGNAGE AND CORNER GUARD PLAN
I-201 WORKSTATION AND DESKING TYPICAL VIEWS AND NOTES
I-202 ENLARGED DEMOUNTABLE PARTITION PLAN AND ELEVATIONS
I-203 ENLARGED DEMOUNTABLE PARTITION PLAN AND ELEVATIONS
I-204 ENLARGED DEMOUNTABLE PARTITION PLAN AND ELEVATIONS
I-205 ENLARGED DEMOUNTABLE PARTITION PLAN AND ELEVATIONS
I-206 ENLARGED DEMOUNTABLE PARTITION PLAN AND ELEVATIONS
I-207 ENLARGED DEMOUNTABLE PARTITION PLAN AND ELEVATIONS
I-208 ENLARGED DEMOUNTABLE PARTITION PLAN AND ELEVATIONS
I-209 ENLARGED DEMOUNTABLE PARTITION PLAN AND ELEVATIONS
INDEX OF DRAWINGS - VOLUME I
SHEET
NUMBER SHEET NAME
GENERAL
G-001A TITLE SHEET - VOLUME I
G-002A DRAWING INDEX
G-003 SITE LOCATION AND ACCESS LOCATION
G-004 STAGING AND LAYDOWN AREA
G-005 CODE SUMMARY
G-101 FIRST FLOOR PLAN - LIFE SAFETY
G-102 SECOND FLOOR PLAN - LIFE SAFETY
G-110 AIR BARRIER 1ST FLOOR PLAN DIAGRAM
G-111 AIR BARRIER 2ND FLOOR PLAN DIAGRAM
G-112 AIR BARRIER SECTION DIAGRAMS
CIVIL
V-101 TOPOGRAPHIC SURVEY
C-001 GENERAL CIVIL NOTES
C-002 GENERAL NOTES AND LEGEND
C-101 DEMOLITION AND REMOVAL PLAN
C-102 OVERALL SITE PLAN
C-103 SITE PLAN NORTHEAST
C-104 SITE PLAN NORTHWEST
C-105 SITE PLAN SOUTHEAST
C-106 SITE PLAN SOUTHWEST
C-107 ALIGNMENT TABLES
C-110 GRADING PAVING AND DRAINAGE OVERALL PLAN
C-111 GRADING PAVING AND DRAINAGE PLAN NORTHEAST
C-112 GRADING PAVING AND DRAINAGE PLAN NORTHWEST
C-113 GRADING PAVING AND DRAINAGE PLAN SOUTHEAST
C-114 GRADING PAVING AND DRAINAGE PLAN SOUTHWEST
C-115 EROSION CONTROL OVERALL PLAN
C-116 EROSION CONTROL PLAN NORTHEAST
C-117 EROSION CONTROL PLAN NORTHWEST
C-118 EROSION CONTROL PLAN SOUTHEAST
C-119 EROSION CONTROL PLAN SOUTHWEST
C-120 OVERALL UTILITY PLAN
C-121 UTILITY PLAN NORTHEAST
C-122 UTILITY PLAN NORTHWEST
C-123 UTILITY PLAN SOUTHEAST
C-124 UTILITY PLAN SOUTHWEST
C-130 CONCRETE LAYOUT AND JOINT PLAN
C-131 CONCRETE LAYOUT AND JOINT PLAN
C-132 CONCRETE LAYOUT AND JOINT PLAN
C-201 B STREET & HEMBY STREET PROFILES
C-202 ACCESS DRIVE PROFILES
C-203 PARKING AISLE PROFILES
C-204 PARKING AISLE PROFILES
C-205 STORM SEWER PROFILES
C-206 SWMF SECTIONS AND UTILITY SEPARATION DETAILS
C-500 PAVING TYPICAL SECTIONS
C-501 PAVING DETAILS
C-502 CIVIL DETAILS
C-503 DRAINAGE DETAILS
C-504 CONCRETE JOINT DETAILS
C-505 EROSION CONTROL DETAILS
C-506 SWMF OVERFLOW DETAIL AND MISCELLANEOUS UTILITY DETAILS
C-507 STORMWATER POLLUTION PREVENTION PLAN
C-600 STORMWATER STRUCTURE TABLES
CATHODIC PROTECTION
X-101 CATHODIC PROTECTION PLAN
X-501 CATHODIC PROTECTION DETAILS
LANDSCAPE
L-100 LANDSCAPING PLAN
L-101 LANDSCAPE DETAILS
STRUCTURAL
S-001 GENERAL NOTES
S-002 GENERAL NOTES & WIND INFORMATION
S-003 SCHEDULES, LEGENDS & NOTES FOR FRAMING PLANS
S-110 FOUNDATIONS & SLAB-ON-GRADE PLAN
S-120 2ND FLOOR & LOW ROOF FRAMING PLAN
S-130 ROOF FRAMING PLAN
S-140 MECHANICAL YARD SCREENWALL PLANS & DETAILS
S-201 FRAMING ELEVATIONS
S-202 CANOPY ELEVATIONS & DETAILS
S-301 BUILDING SECTIONS
S-302 BUILDING SECTIONS
S-401 FOUNDATION SECTIONS
INDEX OF DRAWINGS - VOLUME II
SHEET
NUMBER SHEET NAME
M-602 CONTROLS
M-603 CONTROLS
M-604 CONTROLS
M-605 CONTROLS
M-606 CONTROLS
M-607 CONTROLS
ELECTRICAL
E-001 ELECTRICAL LEGEND AND NOTES
E-002 ELECTRICAL SCHEDULES
E-100 ELECTRICAL SITE PLAN
E-101 OVERALL 1ST FLOOR PLAN
E-102 OVERALL 2ND FLOOR PLAN
E-110 PARTIAL 1ST FLOOR ELECTRICAL LIGHTNING PLAN - WEST
E-111 PARTIAL 1ST FLOOR ELECTRICAL LIGHTNING PLAN - EAST
E-112 PARTIAL 2ND FLOOR ELECTRICAL LIGTHNING PLAN - WEST
E-113 PARTIAL 2ND FLOOR ELECTRICAL LIGTHNING PLAN - EAST
E-120 PARTIAL 1ST FLOOR ELECTRICAL POWER PLAN - WEST
E-121 PARTIAL 1ST FLOOR ELECTRICAL POWER PLAN - EAST
E-122 PARTIAL 2ND FLOOR ELECTRICAL POWER PLAN - WEST
E-123 PARTIAL 2ND FLOOR ELECTRICAL POWER PLAN - EAST
E-130 PARTIAL 1ST FLOOR MECH. POWER PLAN - WEST
E-131 PARTIAL 1ST FLOOR MECH. POWER PLAN - EAST
E-132 PARTIAL 2ND FLOOR MECH. POWER PLAN - WEST
E-133 PARTIAL 2ND FLOOR MECH. POWER PLAN - EAST
E-141 ELECTRICAL ENLARGED PLANS
E-300 LIGHTNING PROTECTION PLAN
E-401 ELECTRICAL DETAILS
E-402 ELECTRICAL DETAILS
E-403 ELECTRICAL DETAILS
E-404 ELECTRICAL DETAILS
E-501 ELECTRICAL SINGLE LINE DIAGRAM
E-502 ELECTRICAL SCHEDULES
E-503 ELECTRICAL SCHEDULES
E-504 ELECTRICAL SCHEDULES
E-505 ELECTRICAL SCHEDULES
E-506 ELECTRICAL SCHEDULES
E-507 ELECTRICAL SCHEDULES
E-508 ELECTRICAL SCHEDULES
E-509 ELECTRICAL SCHEDULES
TELECOMMUNICATIONS
T-001 TELECOMMUNICATIONS LEGEND, NOTES, AND ABBREVIATIONS
T-100 TELECOMMUNICATIONS SITE PLAN
T-101 OVERALL 1ST FLOOR PLAN
T-102 OVERALL 2ND FLOOR PLAN
T-110 PARTIAL 1ST FLOOR TELECOMMUNICATIONS PLAN - WEST
T-111 PARTIAL 1ST FLOOR TELECOMMUNICATIONS PLAN - EAST
T-112 PARTIAL 2ND FLOOR PLAN TELECOMMUNICATIONS PLAN - WEST
T-113 PARTIAL 2ND FLOOR PLAN TELECOMMUNICATIONS PLAN - EAST
T-300 ENLARGED TELECOMMUNICATIONS ROOMS
T-400 TELECOMMUNICATIONS DETAILS
T-401 TELECOMMUNICATIONS DETAILS
T-402 TELECOMMUNICATIONS DETAILS
T-403 TELECOMMUNICATIONS DETAILS
T-404 TELECOMMUNICATIONS DETAILS
T-405 TELECOMMUNICATIONS DETAILS
T-406 TELECOMMUNICATIONS DETAILS
T-407 TELECOMMUNICATIONS DETAILS
T-501 DATA AND VOICE SINGLE LINE DIAGRAM
T-502 SECOND FLOOR DATA AND VOICE SINGLE LINE DIAGRAM
T-503 CATV SINGLE LINE DIAGRAM
T-600 TELECOMMUNICATIONS RACK ELEVATIONS
INDEX OF DRAWINGS - VOLUME II
SHEET
NUMBER SHEET NAME
GENERAL
G-001B TITLE SHEET - VOLUME II
G-002B DRAWING INDEX
FIRE PROTECTION
FA101 FIRST FLOOR PLAN - FIRE ALARM
FA102 SECOND FLOOR PLAN - FIRE ALARM
FA501 DETAILS - FIRE ALARM
FX101 FIRST FLOOR PLAN - FIRE PROTECTION
FX102 SECOND FLOOR PLAN - FIRE PROTECTION
FX501 DETAILS - FIRE PROTECTION
PLUMBING
P-001 PLUMBING LEGEND, NOTES, AND ABBREVIATIONS
P-002 PLUMBING SCHEDULE AND NOTES
P-003 PLUMBING SCHEDULES
P-101 PLUMBING SANITARY & VENT OVERALL FIRST FLOOR PLAN
P-102 PLUMBING SANITARY & VENT OVERALL SECOND FLOOR PLAN
P-110 PARTIAL SANITARY AND VENT 1ST FLOOR PLAN - WEST
P-111 PARTIAL SANITARY AND VENT 1ST FLOOR PLAN - EAST
P-112 PARTIAL SANITARY AND VENT 2ND FLOOR PLAN - WEST
P-113 PARTIAL SANITARY AND VENT 2ND FLOOR PLAN - EAST
P-201 PLUMBING DOMESTIC WATER & GAS OVERALL FIRST FLOOR PLAN
P-202 PLUMBING DOMESTIC WATER & GAS OVERALL SECOND FLOOR PLAN
P-210 PARTIAL DOMESTIC WATER & GAS 1ST FLOOR PLAN - WEST
P-211 PARTIAL DOMESTIC WATER & GAS 1ST FLOOR PLAN - EAST
P-212 PARTIAL DOMESTIC WATER & GAS 2ND FLOOR PLAN - WEST
P-213 PARTIAL DOMESTIC WATER & GAS 2ND FLOOR PLAN - EAST
P-300 PLUMBING SANITARY & VENT RISER DIAGRAM
P-301 PLUMBING DOMESTIC WATER & GAS RISER DIAGRAM
P-400 PLUMBING DETAILS
P-401 PLUMBING DETAILS
P-402 PLUMBING DETAILS
MECHANICAL
M-001 MECHANICAL LEGEND
M-002 MECHANICAL SCHEDULES
M-003 MECHANICAL SCHEDULES
M-004 MECHANICAL SCHEDULES
M-005 MECHANICAL SCHEDULES
M-006 MECHANICAL SCHEDULES
M-101 1ST FLOOR - OVERALL MECHANICAL PLAN
M-102 2ND FLOOR - OVERALL MECHANICAL PLAN
M-110 PARTIAL 1ST FLOOR - MECHANICAL PLAN - WEST
M-111 PARTIAL 1ST FLOOR - MECHANICAL PLAN - EAST
M-112 PARTIAL 2ND FLOOR - MECHANICAL PLAN - WEST
M-113 PARTIAL 2ND FLOOR - MECHANICAL PLAN - EAST
M-201 1ST FLOOR - OVERALL PIPING PLAN
M-202 2ND FLOOR - OVERALL PIPING PLAN
M-210 PARTIAL 1ST FLOOR - PIPING PLAN - WEST
M-211 PARTIAL 1ST FLOOR - PIPING PLAN - EAST
M-212 PARTIAL 2ND FLOOR - PIPING PLAN - WEST
M-213 PARTIAL 2ND FLOOR - PIPING PLAN - EAST
M-301 ENLARGED MECHANICAL PLANS
M-302 ENLARGED MECHANICAL PLANS
M-401 MECHANICAL SECTIONS
M-402 MECHANICAL SECTIONS
M-403 MECHANICAL ROOM SECTION
M-501 MECHANICAL DETAILS
M-502 MECHANICAL DETAILS
M-503 MECHANICAL DETAILS
M-504 MECHANICAL DETAILS
M-505 MECHANICAL DETAILS
M-506 MECHANICAL DETAILS
M-507 MECHANICAL DETAILS
M-508 MECHANICAL DETAILS
M-509 MECHANICAL DETAILS
M-601 CONTROLS
FSA
LOC
L O
C
LOC
XMIT
A B C D E F G H J K M P Q L R S T U V
STAIRS
MASS BRIEFING
ROOM
MECHANICAL
COMM
ELEC
RA
ADO
ARMS
JOINT USE
110AVIATION FLIGHT
EQUIPMENT
BREAKROOM
ELEV. LOBBY
ELEV. EQUIP.
ELEV
SUPPLY
PILOT RESERVE
FLIGHT ROOM
FLIGHT
PLANNING
BRIEFING
BRIEFING
RESERVE SMA
TRAINING
CORRIDOR
CORRIDOR
LOBBY
VEST.
STAIRS
STOR.
105A
JAN
OPS DESK
ACU
FIRST SGT
READINESS
FUNCTIONAL
MOBILITY OIC
TRAINING OIC
SAFETY OIC
WOMENS
MENS
LACTATION
CORRIDOR
CORRIDOR
MENS SHOWER
WOMENS
SHOWER
SUPPLY OFFICE
BRIEFING
BRIEFING
OPS OIC
BRIEFING
ARMS
SUPERVISOR
114A
P P
P
P
P
WP
WPWP
WP
WP
P
MM
MM
MM MM
R R
RR
TEXT
TEXT
MM
MM
MM
MM
MM
MM
T E
X T
TEXT
TEXT
MM
MM
P
P
WP
75 WP
75 WP
75 75
FMCP
FLIGHT ROOM
MANAGER
123A
NVG STORAGE
118A
SMA MANAGER
124A
SPRINKLER CONTROL VALVE
WITH TAMPER SWITCH TO
ELEVATOR MACHINE ROOM
SPRINKLER FLOW SWITCH TO
ELEVATOR MACHINE ROOM
SPRINKLER CONTROL
VALVE WITH TAMPER
SWITCH TO ELEVATOR PIT
MONITOR ELEVATOR
SHUNT TRIP POWER
PRIMARY RECALL, SECONDARY
RECALL, FIRE HAT, AND SHUNT
TRIP OF ELEVATOR POWER
MANUAL PULL STATION
FIRE ALARM AND MASS NOTIFICATION SPEAKER
(CEILING-MOUNTED)
MONITOR MODULE
INDICATES WEATHERPROOFWP
LOCAL OPERATOR CONSOLE (RECESSED)
W/REMOTE MICROPHONE AND HVAC
SHUTDOWN SWITCH
WATERFLOW SWITCH
TAMPER SWITCH
RELAY MODULE
LOC
MM
R
FIRE ALARM LEGEND
P
FIRE ALARM AND MASS NOTIFICATION SPEAKER /
STROBE WITH CLEAR LENS
(WALL-MOUNTED)
XX
XX
XX
CANDELA RATINGXX
FIRE ALARM AND MASS NOTIFICATION SPEAKER
(WALL-MOUNTED)
FIRE ALARM AND MASS NOTIFICATION SPEAKER /
STROBE WITH CLEAR LENS
(CEILING-MOUNTED)
FIRE ALARM AND MASS NOTIFICATION SPEAKER /
STROBE WITH CLEAR LENS
(CEILING-MOUNTED)
TEXT SCOLLING LED TEXT SIGNS
FMCP FIRE ALARM AND MASS NOTIFICATION CONTROL
PANEL
FSA
XMIT
REMOTE ANNUNCIATOR PANEL
MONACO TRANSCEIVER
PHOTOELECTRIC SMOKE DETECTOR
EOL END-OF-LINE RESISTOR
FIRE ALARM NOTES
1. SEE SHEET FA501 FOR FIRE ALARM AND MASS NOTIFICATION
SYSTEM NOTES AND DETAILS.
A
SHEET
IDENTIFICATION
US Army Corps of Engineers ®
Mobile District
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D E
S
IG
N E
D B
Y
B U
L L
O C
K T
IC
E
A S
S O
C
IA
T E
S
E
C
E R
V A
N T
E S
S T
R E
E T
S
U
IT
E B
P
E N
S A
C O
L A
F
L O
R
ID
A
2 3 4 5
B
C
D
D R
A W
N B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
S
U E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
P R
O J
E C
T N
U M
B E
R
F
IL
E N
A M
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E x
M O
B
IL
E D
IS
T
R
IC
T
S
A
IN
T J
O S
E P
H S
T R
E E
T M
O B
IL
E
A
L A
B A
M A
F T
F A
S O
F C
O M
B
IN
E D
S Q
U A
D O
P S
F A
C
IL
IT
Y
D
U K
E F
IE
L
D
W
-2 -R
-0
D U
K E
F
IE
L D
F
L O
R
ID
A
FA101FTFA 163002
F
IR
S T
F L
O O
R P
L A
N
F
IR
E A
L A
R M
J
J O
H N
H
M E
A D
O W
S
J
J O
H N
F
IS
H E
R E
N G
IN
E
E R
IN
G
IN
C
-3
-2
M E
F
F A
.D W
G
3/32" = 1'-0"FA101
1 FIRST FLOOR PLAN - FIRE ALARM
SCALE: 3/32" = 1'-0"
0 5'-4" 10'-8" 21'-4"
PLAN
NORTH
LOC
L O
C
LOC
A B C D E F G H J K M P Q L R S T U V
INTEL TRAINING /
SOC SOUTH
BRIEFING
SOC SOUTH
MISSION
PLANNING
PLANS
FTU CLASSROOM
225A
FTU OPEN
OFFICE
COMMAND SUITE
- ACTIVE
COMMAND SUITE
- RESERVE
BREAKROOM
STAIR
ELEV.
STAND EVAL
CONFERENCE
ROOM
FIRST SGT
WOMENS
MENS
MECHANICAL
ELEC
COMM
COMMANDER
SR ENL MGR
STAIR
DIRECTOR OF
RESERVE OPS
SR ENL MGR
STAIRS
COMMANDER
ELEV. LOBBY
CORRIDOR
INTEL OFFICE
INTEL
SECURE COMM
INTEL OFFICE
INTEL
COMMANDER
DIR OPS
SQUADRON
HEALTH
POTFF
PLANS OIC
TACTICS OIC
WOMENS
SHOWER
CORRIDOR
CORRIDOR
SECURE ROOM
STAND EVAL
SUPERVISOR
222A
TEXT
MM
MM
TEXT
T E
X T
MM
MM
P
15 WP
15 WP
P
P
JAN
MANUAL PULL STATION
FIRE ALARM AND MASS NOTIFICATION SPEAKER
(CEILING-MOUNTED)
MONITOR MODULE
INDICATES WEATHERPROOFWP
LOCAL OPERATOR CONSOLE (RECESSED)
W/REMOTE MICROPHONE AND HVAC
SHUTDOWN SWITCH
WATERFLOW SWITCH
TAMPER SWITCH
RELAY MODULE
LOC
MM
R
FIRE ALARM LEGEND
P
FIRE ALARM AND MASS NOTIFICATION SPEAKER /
STROBE WITH CLEAR LENS
(WALL-MOUNTED)
XX
XX
XX
CANDELA RATINGXX
FIRE ALARM AND MASS NOTIFICATION SPEAKER
(WALL-MOUNTED)
FIRE ALARM AND MASS NOTIFICATION SPEAKER /
STROBE WITH CLEAR LENS
(CEILING-MOUNTED)
FIRE ALARM AND MASS NOTIFICATION SPEAKER /
STROBE WITH CLEAR LENS
(CEILING-MOUNTED)
TEXT SCOLLING LED TEXT SIGNS
FMCP FIRE ALARM AND MASS NOTIFICATION CONTROL
PANEL
FSA
XMIT
REMOTE ANNUNCIATOR PANEL
MONACO TRANSCEIVER
PHOTOELECTRIC SMOKE DETECTOR
EOL END-OF-LINE RESISTOR
FIRE ALARM NOTES
1. SEE SHEET FA501 FOR FIRE ALARM AND MASS NOTIFICATION
SYSTEM NOTES AND DETAILS.
A
SHEET
IDENTIFICATION
US Army Corps of Engineers ®
Mobile District
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D E
S
IG
N E
D B
Y
B U
L L
O C
K T
IC
E
A S
S O
C
IA
T E
S
E
C
E R
V A
N T
E S
S T
R E
E T
S
U
IT
E B
P
E N
S A
C O
L A
F
L O
R
ID
A
2 3 4 5
B
C
D
D R
A W
N B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
S
U E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
P R
O J
E C
T N
U M
B E
R
F
IL
E N
A M
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E x
M O
B
IL
E D
IS
T
R
IC
T
S
A
IN
T J
O S
E P
H S
T R
E E
T M
O B
IL
E
A
L A
B A
M A
F T
F A
S O
F C
O M
B
IN
E D
S Q
U A
D O
P S
F A
C
IL
IT
Y
D
U K
E F
IE
L
D
W
-2 -R
-0
D U
K E
F
IE
L D
F
L O
R
ID
A
FA102FTFA 163002
S E
C O
N D
F L
O O
R P
L A
N
F
IR
E A
L A
R M
J
J O
H N
H
M E
A D
O W
S
J
J O
H N
F
IS
H E
R E
N G
IN
E
E R
IN
G
IN
C
-3
-2
M E
F
F A
.D W
G
3/32" = 1'-0"FA102
1 SECOND FLOOR PLAN - FIRE ALARM
SCALE: 3/32" = 1'-0"
0 5'-4" 10'-8" 21'-4"
FIRE ALARM SYSTEM SEQUENCE OF OPERATION MATRIX
MANUAL PULL STATION
ALARM AT
FMCP & FSA
SUPERVISORY
AT FMCP &
FSA
TROUBLE AT
FMCP & FSA
ALARM AT
RECEIVING
STATION
TROUBLE
AT
RECEIVING
STATION
SUPERVISORY
AT RECEIVING
STATION
ACTIVATE
SPEAKERS
& STROBES
SILENCE
SPEAKERS
& STROBES
REMAIN
ACTIVE
SHUTDOWN
AHU / ERV
SMOKE DETECTOR
WATERFLOW SWITCH
INPUT RECEIVED FROM
MASS NOTIFICATION
SYSTEM (MNS)
TAMPER SWITCH
FIRE ALARM TROUBLE
CONDITION (OPENS,
SHORTS OR GROUNDS)
ALARM SILENCE AT
FMCP OR FSA
DUCT SMOKE
DETECTOR
MNS TROUBLE
OVERRIDE FA
MESSAGE
OVERRIDE
PA
SYSTEM
MNS SYSTEM
TROUBLE AT
RECEIVING
STATION
SHUNT
ELEVATOR
POWER
RECALL
ELEVATOR
TO FIRST
FLOOR
RECALL
ELEVATOR
TO
SECOND
FLOOR
ACTIVATE
FIREFIGHTER
HAT
SMOKE DETECTOR IN
2ND FLOOR LOBBY
SMOKE DETECTOR IN
1ST FLOOR LOBBY
SMOKE DETECTOR
ELEVATOR MACHINE
ROOM
WATERFLOW SWITCH
FOR ELEVATOR
MACHINE ROOM
FIRE ALARM NOTES
1. PROVIDE AN ADDRESSABLE COMBINATION FIRE ALARM/MASS NOTIFICATION
SYSTEM IN ACCORDANCE WITH NFPA 72, NFPA 101, UFC 3-600-01, UFC
4-021-01, THE SPECIFICATION AND THE SCOPE OF WORK DOCUMENTS. THE
FIRE ALARM SYSTEM SHALL BE COMPATIBLE WITH THE MASS NOTIFICATION
SYSTEM RECEIVER AND BE ABLE TO RELAY OUTPUTS FROM THE RECEIVER
OVER THE VOICE EVACUATION SYSTEM TO THE SPEAKERS. THE
CONTRACTOR SHALL COORDINATE WITH THE BASE TO ENSURE THE
RECEIVER IS COMPATIBLE WITH THE BASE-WIDE MASS NOTIFICATION
SYSTEM. MASS NOTIFICATION SIGNALS SHALL TAKE PRECEDENCE OVER FIRE
ALARM SIGNALS.
2. THE FIRE ALARM SYSTEM SHALL MONITOR ALL SPRINKLER SYSTEM ALARM,
SUPERVISORY AND TROUBLE CONDITIONS.
3. AIR HANDLING UNITS OVER 2,000 CFM, SHALL HAVE DUCT SMOKE SENSORS
INSTALLED ON THE SUPPLY DUCTS.
4. ALL SOFTWARE, HARDWARE, PASSWORDS, ETC REQUIRED FOR THE
MAINTENANCE, TESTING, AND REPROGRAMMING OF THE FIRE ALARM SYSTEM
SHALL BE UNCONDITIONALLY TURNED OVER TO THE GOVERNMENT, AND THE
ABOVE NOTED SOFTWARE, HARDWARE, PASSWORDS, ETC WILL BECOME THE
UNCONDITIONAL PROPERTY OF THE GOVERNMENT. SOFTWARE TURNED
OVER TO GOVERNMENT SHALL BE ORIGINAL SOFTWARE ON COMPACT DISK
(CD) WITH JEWELED CASE. COPIES OF SOFTWARE SHALL NOT BE
ACCEPTABLE. SOFTWARE AND CD SHALL BE BRAND NEW AND UNUSED.
PROVIDE AN 8-HOUR BLOCK OF TRAINING ON SOFTWARE, REGARDING
MAINTENANCE, TESTING, AND REPROGRAMMING OF THE FIRE ALARM SYSTEM
FOR 6 PERSONNEL. TRAINING SHALL BE PROVIDED ON SITE.
5. THE FIRE ALARM SYSTEM SHALL REPORT ALL CONDITIONS TO THE BASE-WIDE
REPORTING SYSTEM AS NECESSARY. THE CONTRACTOR SHALL COORDINATE
WITH THE BASE TO ENSURE THE SYSTEM IS COMPATIBLE WITH THE BASE-
WIDE (MONACO BT- XF) SYSTEM AND THE PROPER TRANSMITTING
EQUIPMENT IS PROVIDED. THE TRANSCEIVER SHALL BE PROVIDED AND
INSTALLED BY THE CONTRACTOR AS PART OF THE COMPLETE FIRE ALARM
SYSTEM.
6. THE FIRE ALARM/MNS LAYOUT IS DIAGRAMMATICAL ONLY. THE ACTUAL
BUILDING LAYOUT MAY VARY FROM THE DRAWINGS. THE CONTRACTOR SHALL
VERIFY CEILING HEIGHTS, WALL AND PARTITION LOCATIONS AND DOOR
LOCATIONS PRIOR TO INSTALLATION.
7. ALL FIRE ALARM AND MNS CONDUCTORS SHALL BE SOLID COPPER, CLASS A
AND SHALL BE INSTALLED IN CONDUIT. ALL CONDUIT SHALL BE FACTORY
PAINTED RED.
MANUAL PULL STATION
FIRE ALARM AND MASS NOTIFICATION SPEAKER
(CEILING-MOUNTED)
MONITOR MODULE
INDICATES WEATHERPROOFWP
LOCAL OPERATOR CONSOLE (RECESSED)
W/REMOTE MICROPHONE AND HVAC
SHUTDOWN SWITCH
WATERFLOW SWITCH
TAMPER SWITCH
RELAY MODULE
LOC
MM
R
FIRE ALARM LEGEND
P
FIRE ALARM AND MASS NOTIFICATION SPEAKER /
STROBE WITH CLEAR LENS
(WALL-MOUNTED)
XX
XX
XX
CANDELA RATINGXX
FIRE ALARM AND MASS NOTIFICATION SPEAKER
(WALL-MOUNTED)
FIRE ALARM AND MASS NOTIFICATION SPEAKER /
STROBE WITH CLEAR LENS
(CEILING-MOUNTED)
FIRE ALARM AND MASS NOTIFICATION SPEAKER /
STROBE WITH CLEAR LENS
(CEILING-MOUNTED)
TEXT SCOLLING LED TEXT SIGNS
FMCP FIRE ALARM AND MASS NOTIFICATION CONTROL
PANEL
FSA
XMIT
REMOTE ANNUNCIATOR PANEL
MONACO TRANSCEIVER
PHOTOELECTRIC SMOKE DETECTOR
EOL END-OF-LINE RESISTOR
FMCP
SPEAKER/
STROBES
SPEAKER/
STROBES SPEAKERS SPEAKERS
FLOOR
LOC
FSA
DUCT SMOKE
DETECTORS
R R
AHU / ERV
SHUTDOWN
MANUAL PULL
STATIONS
15 30 30
LOC
MM
SPRINKLER
WATERFLOW
MM
CONTROL
VALVES
OVERRIDE PA
SYSTEM
(FIELD LOCATE
RELAY)
TO
VAC
MM
BACKFLOW
PREVENTER TEST
HEADER (NORMALLY
CLOSED)
R
SMOKE
DETECTOR
TO 120 VAC
PANEL / CIRCUIT
P P
XMIT
30 30 75 75
SPEAKER/
STROBES
SPEAKER/
STROBES
SPD
SPD
EXTERIOR
SPEAKERS
WP WP
R R
ELEVATOR
RECALL
R
ELEVATOR
SHUNT
R
ELEVATOR
FIRE HAT
MM
CONTROL
VALVES
MM MM
STROBES
LOC
" 5
T O
MANUAL PULL
STATION
FMCP
WALL-MOUNTED
SPEAKER/STROBE
FSA
T O
WALL-MOUNTED
STROBE
SCALE: NONEFA501
1 SEQUENCE OF OPERATION MATRIX
A
SHEET
IDENTIFICATION
US Army Corps of Engineers ®
Mobile District
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D E
S
IG
N E
D B
Y
B U
L L
O C
K T
IC
E
A S
S O
C
IA
T E
S
E
C
E R
V A
N T
E S
S T
R E
E T
S
U
IT
E B
P
E N
S A
C O
L A
F
L O
R
ID
A
2 3 4 5
B
C
D
D R
A W
N B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
S
U E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
P R
O J
E C
T N
U M
B E
R
F
IL
E N
A M
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E x
M O
B
IL
E D
IS
T
R
IC
T
S
A
IN
T J
O S
E P
H S
T R
E E
T M
O B
IL
E
A
L A
B A
M A
F T
F A
S O
F C
O M
B
IN
E D
S Q
U A
D O
P S
F A
C
IL
IT
Y
D
U K
E F
IE
L
D
W
-2 -R
-0
D U
K E
F
IE
L D
F
L O
R
ID
A
FA501FTFA 163002
D E
T A
IL
S
F
IR
E
A L
A R
M
J
J O
H N
H
M E
A D
O W
S
J
J O
H N
F
IS
H E
R E
N G
IN
E
E R
IN
G
IN
C
-3
-2
M E
F
F A
.D W
G
SCALE: NONEFA501
3 TYPICAL RISER DIAGRAM
SCALE: NONEFA501
2 FIRE ALARM ELEVATION (TYPICAL)
A B C D E F G H J K M P Q L R S T U V
STAIRS
MASS BRIEFING
ROOM
MECHANICAL
COMM
ELEC
RA
ADO
ARMS
JOINT USE
AVIATION FLIGHT
EQUIPMENT
BREAKROOM
ELEV. LOBBY
ELEV. EQUIP.
ELEV
SUPPLY
PILOT RESERVE
FLIGHT ROOM
FLIGHT
PLANNING
BRIEFING
BRIEFING
RESERVE SMA
TRAINING
CORRIDOR
CORRIDOR
LOBBY
VEST.
STAIRS
STOR.
105A
JAN
OPS DESK
ACU
FIRST SGT
112READINESS
FUNCTIONAL
MOBILITY OIC
TRAINING OIC
SAFETY OIC
WOMENS
MENS
LACTATION
CORRIDOR
CORRIDOR
MENS SHOWER
WOMENS
SHOWER
SUPPLY OFFICE
BRIEFING
BRIEFING
OPS OIC
BRIEFING
ARMS
SUPERVISOR
114A
SPRINKLER LEAD-IN. SEE C-122 FOR
CONTINUATION OF FIRE LINE
TEST HEADER CONNECTION
WATER MOTOR GONG
STANDPIPE
FLIGHT ROOM
MANAGER
123A
SMA MANAGER
124A
NVG STORAGE
118A
PROVIDE SPRINKLER FLOW SWITCH FOR SHUNT TRIP
OF ELEVATOR POWER AND CONTROL VALVE WITH
TAMPER SWITCH TO ELEVATOR MACHINE ROOM.
LOCATE OUTSIDE THE ELEVATOR MACHINE ROOM
PROVIDE SPRINKLER CONTROL
VALVE WITH TAMPER SWITCH
TO ELEVATOR PIT SPRINKLER
LIGHT HAZARD
0.10 GPM/SF OVER HYDRAULICALLY
MOST REMOTE 1,500 SF
WATER MOTOR GONG
ORDINARY HAZARD
0.20 GPM/SF OVER HYDRAULICALLY
MOST REMOTE 2,500 SF
FIRE PROTECTION LEGEND
TEST HEADER
FIRE PROTECTION NOTES
1. SEE SHEET FX501 FOR FIRE PROTECTION NOTES AND DETAILS.
A
SHEET
IDENTIFICATION
US Army Corps of Engineers ®
Mobile District
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D E
S
IG
N E
D B
Y
B U
L L
O C
K T
IC
E
A S
S O
C
IA
T E
S
E
C
E R
V A
N T
E S
S T
R E
E T
S
U
IT
E B
P
E N
S A
C O
L A
F
L O
R
ID
A
2 3 4 5
B
C
D
D R
A W
N B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
S
U E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
P R
O J
E C
T N
U M
B E
R
F
IL
E N
A M
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E x
M O
B
IL
E D
IS
T
R
IC
T
S
A
IN
T J
O S
E P
H S
T R
E E
T M
O B
IL
E
A
L A
B A
M A
F T
F A
S O
F C
O M
B
IN
E D
S Q
U A
D O
P S
F A
C
IL
IT
Y
D
U K
E F
IE
L
D
W
-2 -R
-0
D U
K E
F
IE
L D
F
L O
R
ID
A
FX101FTFA 163002
F
IR
S T
F L
O O
R P
L A
N
F
IR
E P
R O
T E
C T
IO
N
J
J O
H N
H
M E
A D
O W
S
J
J O
H N
F
IS
H E
R E
N G
IN
E
E R
IN
G
IN
C
-3
-2
M E
F
F X
.D
W G
3/32" = 1'-0"FX101
1 FIRST FLOOR PLAN - FIRE PROTECTION
SCALE: 3/32" = 1'-0"
0 5'-4" 10'-8" 21'-4"
A B C D E F G H J K M P Q L R S T U V
INTEL TRAINING /
SOC SOUTH
BRIEFING
SOC SOUTH
MISSION
PLANNING
PLANS
FTU CLASSROOM
225A
FTU OPEN
OFFICE
COMMAND SUITE
- ACTIVE
COMMAND SUITE
- RESERVE
BREAKROOM
STAIR
ELEV.
STAND EVAL
CONFERENCE
ROOM
FIRST SGT
WOMENS
MENS
MECHANICAL
ELEC
COMM
COMMANDER
SR ENL MGR
STAIR
DIRECTOR OF
RESERVE OPS
211SR ENL MGR
STAIRS
COMMANDER
ELEV. LOBBY
CORRIDOR
INTEL OFFICE
INTEL
SECURE COMM
INTEL OFFICE
INTEL
COMMANDER
DIR OPS
SQUADRON
HEALTH
POTFF
PLANS OIC
235TACTICS OIC
WOMENS
SHOWER
CORRIDOR
CORRIDOR
SECURE ROOM
STAND EVAL
SUPERVISOR
222A
STANDPIPE
JAN
LIGHT HAZARD
0.10 GPM/SF OVER HYDRAULICALLY
MOST REMOTE 1,500 SF
WATER MOTOR GONG
ORDINARY HAZARD
0.20 GPM/SF OVER HYDRAULICALLY
MOST REMOTE 2,500 SF
FIRE PROTECTION LEGEND
TEST HEADER
FIRE PROTECTION NOTES
1. SEE SHEET FX501 FOR FIRE PROTECTION NOTES AND DETAILS.
A
SHEET
IDENTIFICATION
US Army Corps of Engineers ®
Mobile District
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D E
S
IG
N E
D B
Y
B U
L L
O C
K T
IC
E
A S
S O
C
IA
T E
S
E
C
E R
V A
N T
E S
S T
R E
E T
S
U
IT
E B
P
E N
S A
C O
L A
F
L O
R
ID
A
2 3 4 5
B
C
D
D R
A W
N B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
S
U E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
P R
O J
E C
T N
U M
B E
R
F
IL
E N
A M
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E x
M O
B
IL
E D
IS
T
R
IC
T
S
A
IN
T J
O S
E P
H S
T R
E E
T M
O B
IL
E
A
L A
B A
M A
F T
F A
S O
F C
O M
B
IN
E D
S Q
U A
D O
P S
F A
C
IL
IT
Y
D
U K
E F
IE
L
D
W
-2 -R
-0
D U
K E
F
IE
L D
F
L O
R
ID
A
FX102FTFA 163002
S E
C O
N D
F L
O O
R P
L A
N
F
IR
E P
R O
T E
C T
IO
N
J
J O
H N
H
M E
A D
O W
S
J
J O
H N
F
IS
H E
R E
N G
IN
E
E R
IN
G
IN
C
-3
-2
M E
F
F X
.D
W G
3/32" = 1'-0"FX102
1 SECOND FLOOR PLAN - FIRE PROTECTION
SCALE: 3/32" = 1'-0"
0 5'-4" 10'-8" 21'-4"
FIRE PROTECTION NOTES
1. THE CONTRACTOR SHALL HYDRAULICALLY DESIGN AN AUTOMATIC WET
PIPE FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA 13,
UFC 3-600-01, THE SPECIFICATION AND THE SCOPE OF WORK DOCUMENTS.
SPRINKLERS SHALL BE INSTALLED IN ALL AREAS REQUIRED TO BE
PROTECTED BY NFPA 13 AND NFPA 101.
2. CONTRACTOR SHALL PROVIDE ALL NECESSARY AUXILIARY DRAINS AND
INSPECTORS' TEST CONNECTIONS AS REQUIRED BY NFPA 13. INSPECTORS'
TEST CONNECTIONS DRAINS SHALL DISCHARGE TO A SAFE LOCATION
OUTSIDE THE BUILDING.
3. CONTRACTOR SHALL PROVIDE ALL NECESSARY PIPE HANGERS AND
SUPPORTS AS REQUIRED BY NFPA 13.
4. ALL WATERFLOW SWITCHES SHALL BE CONNECTED TO THE FIRE ALARM
SYSTEM BY THE FIRE ALARM CONTRACTOR.
5. ALL VALVES CONTROLLING WATERFLOW TO THE SPRINKLER SYSTEM SHALL
BE PROVIDED WITH TAMPER SWITCHES TO BE CONNECTED TO THE FIRE
ALARM SYSTEM BY THE FIRE ALARM CONTRACTOR.
6. ALL PENETRATIONS THROUGH FIRE-RESISTANT ASSEMBLIES SHALL BE
PROTECTED BY A UL-LISTED THROUGH-PENETRATION FIRESTOP SYSTEM.
ALL PENETRATIONS THROUGH SMOKE PARTITIONS SHALL BE SEALED WITH
NON-COMBUSTIBLE MATERIAL.
7. CONTRACTOR SHALL BE RESPONSIBLE FOR AVOIDING ALL CONFLICTS WITH
LIGHTING FIXTURES, DIFFUSERS, GRILLS, DUCTS, CABLE TRAYS, CABLE
BUNDLES, CONDUIT, UTILITY PIPING AND ALL OTHER OBSTRUCTIONS
ENCOUNTERED.
8. CONTRACTOR SHALL VERIFY ELEVATIONS AND LOCATIONS OF NEW
SPRINKLER PIPING AND EQUIPMENT PRIOR TO INSTALLATION.
9. CONTRACTOR SHALL TAKE ALL NECESSARY MEASURES TO KEEP THE
PREMISES DRY AT ALL TIMES AND TO PREVENT WATER DAMAGE.
CONTRACTOR SHALL REPAIR WATER DAMAGE RESULTING FROM THE
WORK, WHETHER INTENTIONAL OR NOT, AT NO COST TO, AND TO THE
SATISFACTION OF THE OWNER.
10. NEITHER THE OWNER NOR THE ENGINEER SHALL BE RESPONSIBLE FOR
PROVIDING A SAFE WORKING PLACE FOR THE CONTRACTOR,
SUBCONTRACTORS, OR THEIR EMPLOYEES, OR ANY OTHER INDIVIDUAL
RESPONSIBLE TO THEM FOR THE WORK. THIS RESPONSIBILITY RESTS
SOLELY ON THE CONTRACTOR'S PROJECT SUPERINTENDENT.
11. ALL PIPING IN AREAS WITH SUSPENDED CEILINGS SHALL BE CONCEALED
ABOVE CEILINGS. ALL EXPOSED PIPE SHALL BE PAINTED AND/OR LABELED
IN ACCORDANCE WITH THE SPECIFICATION.
12. PIPE LAYOUT, SIZES AND ROUTING ARE DIAGRAMMATICAL ONLY. THE
CONTRACTOR SHALL VERIFY PIPING AND SPRINKLER LOCATIONS IN THE
FIELD PRIOR TO INSTALLATION. THE CONTRACTOR SHALL SIZE ALL PIPING
ACCORDING TO THE AVAILABLE WATER SUPPLY.
13. THE BACKFLOW PREVENTER TEST HEADER CONTROL VALVE SHALL BE
MONITORED VIA THE FMCP IN THE NORMALLY CLOSED POSITION.
14. INSPECTOR'S TEST CONNECTION SHALL BE INSTALLED AT THE REMOTE
BRANCH LINE AT EACH LEVEL.
15. A HYDRANT FLOW TEST WAS CONDUCTED ON JANUARY 23, 2019 AT 10:13
AM BY FISHER ENGINEERING RESULTING IN A STATIC PRESSURE OF 60 PSI
AND A RESIDUAL PRESSURE OF 56 PSI WHILE FLOWING 1,060 GPM.
6" DUCTILE IRON
COMPACTED BACKFILL
CONCRETE THRUST BLOCKING
SEAL SPACE BETWEEN PIPE
AND FLOOR WITH FLEXIBLE
WATERPROOF MATERIAL
SLAB ON GRADE, RE: PLAN
DIAMETER OF FLOOR OPENING
SHALL BE 4" LARGER THAN PIPE
DIAMETERCMU WALL
FLANGED SPIGOT PIECE
TERMINATE 1'-0" A.F.F., DRILLED
TO ANSI B16- CLASS 125
RODS
PRESSURE GUAGE
ALARM CHECK VALVE
ASSEMBLY WITH WATER
MOTOR GONG
DRAIN VALVE
OS&Y VALVE
TEST HEADER
EXTERIOR WALL
OS&Y VALVE
VANE-TYPE
WATERFLOW
SWITCH
TO RISER
NOTE: SEE CIVIL DRAWINGS FOR BACKFLOW
PREVENTER AND REMOTE, FREE-STANDING
FIRE DEPARTMENT CONNECTION LOCATIONS.
INDICATING-TYPE FLOOR CONTROL
VALVE WITH SUPERVISORY SWITCH
TO DRAIN
RISER
TO SYSTEM
WATER FLOW SWITCH
PRESSURE GAUGE
CHECK VALVE
STAIR LANDING
4'
A F
F
7'
A F
F
6-
IN
C H
S P
R
IN
K
LE
R R
IS
E
R
SCALE: 3/4" = 1'-0"
0 8" 1'-4" 2'-8"
A
SHEET
IDENTIFICATION
US Army Corps of Engineers ®
Mobile District
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D E
S
IG
N E
D B
Y
B U
L L
O C
K T
IC
E
A S
S O
C
IA
T E
S
E
C
E R
V A
N T
E S
S T
R E
E T
S
U
IT
E B
P
E N
S A
C O
L A
F
L O
R
ID
A
2 3 4 5
B
C
D
D R
A W
N B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
S
U E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
P R
O J
E C
T N
U M
B E
R
F
IL
E N
A M
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E x
M O
B
IL
E D
IS
T
R
IC
T
S
A
IN
T J
O S
E P
H S
T R
E E
T M
O B
IL
E
A
L A
B A
M A
F T
F A
S O
F C
O M
B
IN
E D
S Q
U A
D O
P S
F A
C
IL
IT
Y
D
U K
E F
IE
L
D
W
-2 -R
-0
D U
K E
F
IE
L D
F
L O
R
ID
A
FX501FTFA 163002
D E
T A
IL
S
F
IR
E
P R
O T
E C
T
IO
N
J
J O
H N
H
M E
A D
O W
S
J
J O
H N
F
IS
H E
R E
N G
IN
E
E R
IN
G
IN
C
-3
-2
M E
F
F X
.D
W G
SCALE: NONEFX501
2 STUB-IN DETAIL (TYPICAL)
1/2" = 1'-0"FX501
3 RISER DETAIL
NOT TO SCALEFX501
1 FLOOR CONTROL VALVE (TYPICAL)
SHEET NOTE
HOT WATER RETURN PIPING
HOSE BIBB (HB) OR
WALL HYDRANT (WH)
CLEANOUT TO FLOOR
FLOOR DRAIN
CLEANOUT TO GRADE
VENT THRU ROOF
FD
COTG
VTR
UNION
CO
SANITARY PIPING
COLD WATER SUPPLY PIPING
HOT WATER SUPPLY PIPING
VENT PIPING
G GAS PIPING
LEGEND
ABBREVIATIONS GENERAL NOTES
AAV
ABA
AFF
BFP
CFH
CFM
CFU
CO
CONC
COTG
CP
CW
DF
DFU
DIA
DN
EL OR
ELEV
EWC
FCO
FD
FS
FT
FV
GALV
GPC
GPF
GPM
GWH
HFU
HW
HWR
INV
MECH
MV
NC
NG
NO
PSI
S
SD
SH
SK
SS
TLT
TYP
U
V
VTR
W W/
WC
WCO
WH
WHA
AIR ADMITTANCE VALVE
ARCHITECTURAL BARRIERS ACT
ABOVE FINISH FLOOR
BACKFLOW PREVENTER
CUBIC FEET PER HOUR
CUBIC FEET PER MINUTE
COLD WATER FIXTURE UNITS
CLEANOUT
CONCRETE
CLEANOUT TO GRADE
CIRCULATION PUMP
COLD WATER
DRINKING FOUNTAIN
DRAINAGE FIXTURE UNITS
DIAMETER
DOWN
ELEVATION
ELECTRICAL WATER COOLER
FLOOR CLEANOUT
FLOOR DRAIN
FLOW SWITCH
FOOT OR FEET
FLUSH VALVE
GALVANIZED
GALLONS PER CYCLE
GALLONS PER FLUSH
GALLONS PER MINUTE
GAS WATER HEATER
HOT WATER FIXTURE UNITS
HOT WATER
HOT WATER RETURN
INVERT
MECHANICAL
MIXING VALVE
NORMALLY CLOSED
NATURAL GAS
NORMALLY OPEN
POUNDS PER SQUARE INCH
SANITARY
SHOWER DRAIN
SHOWER
SINK
STAINLESS STEEL
TOILET
TYPICAL
URINAL
VENT
VENT THROUGH ROOF
WASTE
WITH
WATER CLOSET (TOILET)
WALL CLEANOUT
WALL HYDRANT
WATER HAMMER ARRESTOR
1. CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS, SIZES, AND CONNECTION LOCATIONS BEFORE ANY PIPE CUTTING IS COMMENCED.
2. THE PIPING SHOWN ON THESE DRAWINGS ARE DIAGRAMMATIC. CONTRACTOR SHALL ARRANGE WORK IN A NEAT AND ORDERLY MANNER.
THE CONTRACTOR SHALL MAKE ANY OFFSETS, TRANSITIONS, AND OTHER MINOR ADJUSTMENTS AS REQUIRED FOR A COMPLETE AND WORKING SYSTEM INSTALLATION. COORDINATE ALL PIPING WITH DUCTWORK SHOP DRAWINGS. ROUTE PIPING AS REQUIRED TO AVOID
CONFLICTS.
3. PRIOR TO START OF ANY WORK, COORDINATE SANITARY SEWER AND POTABLE WATER PIPING WITH CIVIL DRAWINGS. FIELD VERIFY PIPE
INVERTS PRIOR TO LAYING OUT SANITARY SEWER PIPING.
4. CONTRACTOR SHALL PROVIDE ALL TEMPORARY OR PERMANENT CAPS FOR PIPING. CONTRACTOR SHALL NOT LEAVE PIPING OPEN ENDED.
5. DRAWINGS SHOW GENERAL SIZE AND APPROXIMATE LOCATIONS. THE DRAWINGS ARE INTENDED TO SHOW THE GENERAL ARRANGEMENT
OF THE UTILITY SYSTEM. THE CONTRACTOR SHALL FIELD VERIFY ALL UTILITY CONNECTIONS SIZE, LOCATION, DEPTH. THE CONTRACTOR SHALL INSTALL ALL SYSTEMS ACCORDING TO THE ACTUAL FIELD CONDITIONS FOUND. ANY PLUMBING SYSTEM COMPONENT INSTALLED INCORRECTLY DUE TO FIELD CONDITIONS SHALL BE REMOVED AND INSTALLED CORRECTLY AT THE EXPENSE OF THE CONTRACTOR.
6. REFER TO RISERS FOR SIZES NOT INDICATED ON PLAN VIEWS. RISERS ARE DIAGRAMMATIC AND ARE NOT INTENDED TO INDICATE ALL
OFFSETS, BENDS, FITTINGS, ETC.
7. CONTRACTOR SHALL PROVIDE ALL CONNECTIONS, FITTINGS, APPURTENANCES, ETC. AS NECESSARY FOR INSTALLATION AND OPERATION OF
OWNER FURNISHED EQUIPMENT.
8. INSTALL ALL EQUIPMENT AND PIPING PER MANUFACTURERS REQUIREMENTS AND TO MANUFACTURERS RECOMMENDED CLEARANCES.
9. ALL TRAP PRIMERS AND DOMESTIC WATER ISOLATION VALVES SHALL BE ACCESSIBLE. ISOLATION VALVES SHALL BE OF THE QUARTER TURN
BALL TYPE.
10. PROVIDE ACCESS DOORS/PANELS IN NON-ACCESSIBLE WALLS AND CEILINGS FOR ALL VALVES, SHOCK ABSORBERS, AND ALL OTHER ITEMS
THAT REQUIRE ACCESS FOR PROPER MAINTENANCE. COORDINATE COLOR AND INSTALLATION OF ACCESS DOORS WITH ARCHITECTURAL.
11. BALL VALVES SHALL BE PROVIDED ON ALL WATER BRANCH LINES TO ALL EQUIPMENT, HOSE BIBBS, AND RISER TAKE-OFFS.
12. THE CONTRACTOR SHALL NOT CUT ANY STRUCTURAL MEMBERS OF BUILDING.
13. DO NOT MOUNT DISCONNECT SWITCHES ON PLUMBING EQUIPMENT EXCEPT AS RECOMMENDED BY MANUFACTURER.
14. CONTRACTOR TO COORDINATE WITH OTHER TRADES AS REQUIRED FOR INSTALLATION OF EQUIPMENT AND ANY OTHER PLUMBING ITEMS.
15. ALL PIPING PENETRATIONS OF FIREWALLS, CEILINGS, FLOORS, ETC. SHALL BE UL LISTED FIRESTOPS AND SHALL BE INSTALLED AS PER
MANUFACTURER'S RECOMMENDATION. CONTRACTOR SHALL OBTAIN MANUFACTURER SHOP DRAWINGS AT JOBSITE FOR ALL
PENETRATIONS.
16. ALL VENT THROUGH ROOF (VTR) PENETRATIONS INDICATED ON PLANS ARE PRELIMINARY. FINAL LOCATIONS SHALL BE COORDINATED WITH ALL TRADES. ALL VTR'S SHALL BE A MINIMUM OF 10'-0" FROM ALL FRESH AIR INTAKE OPENINGS
17. PROVIDE ESCUTCHEON PLATES FOR ALL WALL PIPING PENETRATIONS.
18. CONTRACTOR SHALL PROVIDE ALL CONNECTIONS, FITTINGS, APPURTENANCES, ETC. AS NECESSARY FOR INSTALLATION AND OPERATION OF
OWNER FURNISHED EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS.
19. COMPLY WITH SPECIFICATIONS FOR PIPE SLEEVES, HANGER SELECTIONS, AND APPLICATIONS.
20. ENGAGE A FACTORY AUTHORIZED SERVICE REPRESENTATIVE TO PERFORM START-UP SERVICES AND TO TRAIN OWNER'S MAINTENANCE
PERSONNEL TO ADJUST, OPERATE AND MAINTAIN EQUIPMENT.
21. ALL ITEMS PROJECTING THROUGH ROOF SHALL BE FLASHED AND COUNTER-FLASHED A MINIMUM OF 12" AND SHALL BE PAINTED TO MATCH
ROOF COLOR. PROVIDE APPROVED SEALS AT ALL ROOF PENETRATIONS.
22. PROVIDE PREFABRICATED WATER HAMMER ARRESTOR AT EACH NEW BATHROOM GROUP ON HOT AND COLD WATER PIPING.
23. PROVIDE VACUUM BREAKERS AT FIXTURES WITH HOSE THREAD CONNECTIONS.
24. PROVIDE DIELECTRIC UNIONS AT ALL DISSIMILAR METAL PIPE CONNECTIONS.
25. UNDER SLAB SOIL, WASTE AND VENT PIPING PASSING TO UNDERSIDE OR THROUGH FOUNDATION FOOTING, WALL OR GRADE BEAM SHALL BE
PROVIDED WITH A RELIEVING ARCH OR PIPE SLEEVE 2 (TWO) PIPE SIZES GREATER THAN PIPE SIZE INDICATED ON PLANS. COORDINATE FINAL
PIPE ROUTING AND LAYOUT WITH STRUCTURAL DRAWINGS.
26. SEE TOILET ROOM ELEVATIONS ON ARCHITECTURAL DRAWINGS FOR PLUMBING FIXTURE MOUNTING HEIGHT.
27. COORDINATE EXACT LOCATION OF ALL EXTERIOR WALL HYDRANTS WITH ARCHITECT DRAWINGS.
28. PRIOR TO SUBSTANTIAL COMPLETION OF NEW WORK AREAS, CONTRACTOR SHALL HAVE SANITARY PLUMBING SYSTEM CLEARED OF DEBRIS
OR ANY MATTER THAT WOULD INTERFERE OR PREVENT ADEQUATE CONVEYANCE OF MATERIALS FROM MOVING THROUGH AND
TERMINATING INTO BUILDING OR PUBLIC DISPOSAL FACILITIES.
29. COORDINATE FLOOR DRAIN LOCATIONS IN GANG TOILET ROOMS WITH ARCHITECTURAL PLANS.
30. ALL COMPONENTS OF PLUMBING SYSTEMS ARE TO BE INSTALLED PER MANUFACTURERS INSTRUCTIONS.
31. WATER LINES FOR ICE MAKERS SHALL BE BRAIDED STAINLESS STEEL.
32. ALL WORK SHALL COMPLY WITH THE FOLLOWING AGENCIES:
-2018 INTERNATIONAL BUILDING CODE
-2018 INTERNATIONAL PLUMBING CODE
-2018 INTERNATION FUEL GAS CODE
-NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
-AMERICAN SOCIETY OF HEATING AND REFRIGERATION ENGINEERS (ASHRAE)
-UFC 3-420-01 PLUMBING
-ALL APPLICABLE LOCAL CODES, ORDINANCES, AND THE AUTHORITY HAVING JURISDICTION
WATER HAMMER ARRESTOR
EQUIPMENT TAG
DRAWING DESCRIPTION
GATE VALVE
BALL VALVE
BUTTERFLY VALVE
SWING CHECK VALVE
SPRING CHECK VALVE
PRESSURE REDUCING VALVE
PRESSURE RELIEF VALVE. PIPE
FULL SIZE DISCHARGE TO FLOOR DRAIN.
GLOBE VALVE
THERMAL EXPANSION VALVE
ANGLE VALVE
SOLENOID VALVE
FLEXIBLE PIPE CONNECTOR
STRAINER WITH BLOW DOWN GATE VALVE FULL
SIZE OF STRAINER AND 3/4" HOSE END
CONNECTION WITH CAP
ELBOW TURN UP
ELBOW TURN DOWN
CONNECTION, BOTTOM
CONNECTION, TOP
PIPE SIZE TRANSITION
PRV
EF
NOT TO SCALE
DETAIL
P-XXX
CONSULTING GROUP,INC.
WILLIAM JOSEPH JONES P.E.
FLORIDA LICENSE NUMBER 58080
901 W. Garden St. Pensacola, FL 32502
P: 850-438-0050 F: 850-432-8631
FLORIDA LICENSE NUMBER 05371
MECHANICAL ELECTRICAL STRUCTURAL
COMMUNICATIONS INDUSTRIAL
S C H M I D T
SCG PROJECT: 2018-129
A
SHEET
IDENTIFICATION
US Army Corps of
Engineers ®
Mobile District
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D E
S
IG
N E
D B
Y
B U
L L
O C
K T
IC
E
A S
S O
C
IA
T E
S
E
C
E R
V A
N T
E S
S T
R E
E T
S
U
IT
E B
P E
N S
A C
O L
A F
L O
R
ID
A
2 3 4 5
B
C
D
D R
A W
N B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
S
U E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
P R
O J E
C T
N U
M B
E R
F
IL
E N
A M
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E x
M O
B
IL
E D
IS
T
R
IC
T
S
A
IN
T J
O S
E P
H S
T R
E E
T
M O
B
IL
E A
L A
B A
M A
F T
F A
S O
F C
O M
B
IN
E D
S Q
U A
D O
P S
F A
C
IL
IT
Y
D
U K
E F
IE
L
D
D U
K E
F
IE
L D
F
L O
R
ID
A
P-001FTFA 163002
P L
U M
B
IN
G L
E G
E N
D
N O
T E
S
A N
D A
B B
R E
V
IA
T
IO
N S
C
P E
T E
R S
O N
C
P E
T E
R S
O N
C
D A
Y
W
J O
N E
S
-3
-2
M E
F
P
.D W
GW
-2
-R
-0
PLUMBING FIXTURE SCHEDULE
MARK
FIXTURE CONNECTIONS
FIXTURE NAME TYPE
BASIS OF
DESIGN DESCRIPTION
WASTE CW HW
IN IN IN
P-1 WATER CLOSET FLOOR MOUNT
AMERICAN
STANDARD
FLOOR MOUNT, ELONGATED, TOP SPUD, VITREOUS CHINA, 15" RIM HEIGHT, WHITE TOILET SEAT. COMPLIES WITH ANSI/ASME A112.19.2/ CSA B45.1-08
3 1 -
AMERICAN
STANDARD
1.28 GPF, MANUAL, FLUSH VALVE, SELF CLEANING, CHROME PLATED. COMPLIES WITH ASSE 1037 AND ANSI/ASME A112.19.2
P-1A WATER CLOSET (ABA) FLOOR MOUNT
AMERICAN
STANDARD
FLOOR MOUNT, ELONGATED, TOP SPUD, VITREOUS CHINA, ABA RIM HEIGHT, WHITE OPEN FRONT TOILET SEAT. COMPLIES WITH ANSI/ASME A112.19.2 AND CSA B45.
3 1 -
AMERICAN
STANDARD
1.28 GPF, MANUAL, FLUSH VALVE, SELF CLEANING, CHROME PLATED. COMPLIES WITH ASSE 1037 AND ANSI/ASME A112.19.2
P-2 URINAL (ABA) WALL MOUNT
AMERICAN
STANDARD
TOP SPUD, VITREOUS CHINA, ELONGATED RIM. PROVIDE WITH CONCEALED WALL SUPPORTS. COMPLIES WITH ASME A112.19.2-2008/CSA B45.1-08 AND ANSI A117.1
2 3/4 -
AMERICAN
STANDARD
0.125 GPF, MANUAL FLUSH VALVE, SELF CLEANING, CHROME PLATED. PROVIDE WITH WALL CARRIER WITH CONCEALED ARMS. COMPLIES WITH ASSE 1037
AND ANSI/ASME A112.19.2
P-3 LAVATORY COUNTERMOUNT
AMERICAN
STANDARD
20"x17", SELF RIMMING, VITREOUS CHINA, 6-5/8" BOWL DEPTH. 4" CENTERSET FAUCET HOLES. COORDINATE OPENINGS WITH FAUCET. NO CAPPED
OPENINGS ALLOWED. COMPLIES WITH ANSI/ASME A112.19.2, ANSI A117.1, AND CSA B45.
2 1/2 1/2
AMERICAN
STANDARD
4" CENTERSET, CHROME PLATED, SLOW-CLOSING PUSH BUTTON METERING FAUCET WITH INTEGRAL SHANKS, EASY ADJUSTABLE CYCLE TIME, PRESET TO 10 SECONDS. PROVIDE WITH .25 GPC FLOW. PROVIDE WITH POINT OF USE MIXING VALVE. COMPLIES WITH ANSI A112.18.1 AND A117.1.
P-4 SINK COUNTERMOUNT
ELKAY
19" x 17", 6 1/8" BOWL DEPTH, FULLY UNDERCOATED. SINGLE BOWL #20 GAUGE STAINLESS STEEL WITH INTEGRAL MOUNTING RIM. 4" CENTERSET FAUSCET HOLES. COORDINATE OPENINGS WITH FAUCET. NO CAPPED OPENINGS. COMPLIES WITH ANSI A112.19.3M.
2 1/2 1/2
AMERICAN
STANDARD
4" CENTERSET, 0.5 GPM, TOP MOUNT, SWIVEL SPOUT, VANDAL RESISTANT COLOR CODED METAL LEVER HANDLES, CHROME PLATED, LESS SPRAY.
COMPLIES WITH ASME A112.18.1 AND CSA B 125.
P-5 SINK COUNTERMOUNT
ELKAY
27" x 18", 8" BOWL DEPTH, FULLY UNDERCOATED. SINGLE BOWL #20 GAUGE STAINLESS STEEL WITH INTEGRAL MOUNTING RIM. COORDINATE OPENINGS
WITH FAUCET. NO CAPPED OPENINGS. COMPLIES WITH ANSI A112.19.3M.
2 1/2 1/2
AMERICAN
STANDARD
0.5 GPM, TOP MOUNT, SWIVEL SPOUT, VANDAL RESISTANT COLOR CODED METAL LEVER HANDLES, CHROME PLATED, LESS SPRAY. COMPLIES WITH
ASME A112.18.1 AND CSA B 125.
P-6 SHOWER -
- REFER TO ARCHITECTURE FOR SHOWER WALLS AND FLOOR.
- 1/2 1/2AMERICAN
STANDARD
1.5 GPM SHOWER HEAD, PRESSURE BALANCE VALVE WITH CAST BRASS BODY, ADJUSTABLE HOT LIMIT SAFETY STOP, CHROME FINISH. COMPLIES WITH ANSI A
117.1, ASSE 1016, ASME A112.18.1, AND CSA B125.1.
P-6A SHOWER ABA
- REFER TO ARCHITECTURE FOR SHOWER WALLS AND FLOOR.
- 1/2 1/2AMERICAN
STANDARD
1.5 GPM SHOWER SYSTEM, PRESSURE BALANCE VALVE WITH CAST BRASS BODY, ADJUSTABLE HOT LIMIT SAFETY STOP, HAND HELD SHOWER HEAD, 25" SLIDE BAR, ADJUSTABLE HANDSHOWER HOLDER, HOSE, CHROME FINISH. COMPLIES WITH ANSI A 117.1, ASSE 1016, ASME A112.18.1.
P-7 MOP SINK -
FIAT
36"x36"x12" CORNER MODEL, PRECAST TERRAZZO MADE OF MARBLE CHIPS CAST IN WHITE PORTLAND CEMENT, S.S. STRAINTER, S.S. BUMPER GUARD ON
ALL CURBS.
3 1/2 1/2
ZURN CHROME PLATED, ADJUSTABLE WALL BRACE, PAIL HOOK, FOUR ARM HANDLES, HOSE THREADED SPOUT. COMPLIES WITH ASME A112.18.1-2005/CSA B125.1-2005
P-8 DRINKING FOUNTAIN - ELKAY
DOUBLE HUNG WATER FOUNTAIN WITH INTEGRAL BOTTLE FILLING STATION SHALL DELIVER 8 GPH OF 50°F DRINKING WATER AT 90°F AMBIENT AND 80°F INLET WATER. UNITS SHALL BE STAINLESS STEEL CONSTRUCTION. SENSOR-ACTIVATION WITH AN AUTO 20-SECOND SHUT-OFF TIMER. BOTTLE FILLER SHALL PROVIDE 1.1 GPM FLOW RATE. UNIT SHALL MEET ADA GUIDELINES. UNIT SHALL BE LEAD-FREE DESIGN WHICH IS CERTIFIED TO NSF/ANSI 61 AND 372 AND MEETS FEDERAL AND STATE LOW-LEAD REQUIREMENTS. UNIT SHALL BE CERTIFIED TO UL399 AND CAN/CSA 22.2 NO. 120 120V/60Hz/1PH. 5.0 FLA. UNIT SHALL BE
PROVIDED WITH A FILTER. SEE ARCHITECTURAL FOR MOUNTING ELEVATION.
1 1/2 1/2 -
P-9 ICE MAKER BOX - OATEY METAL BOX AND FACE PLATE, QUARTER TURN BALL VALVE, COPPER SWEAT - 1/2 -
FD FLOOR DRAIN - ZURN CAST IRON BODY, BOTTOM OUTLET, INVERTIBLE MEMBRANE CLAMP, ADJUSTABLE COLLAR, NICKEL BRONZE STRAINER, TRAP PRIMER CONNECTION. 3 1/2 -
SD SHOWER DRAIN - ZURN CAST IRON BODY, BOTTOM OUTLET, INVERTIBLE MEMBRANE CLAMP, ADJUSTABLE COLLAR, NICKEL BRONZE STRAINER, TRAP PRIMER CONNECTION. 2 1/2 -
WH WALL HYDRANT - WOODFORD
AUTOMATIC DRAINING, FREEZELESS, WITH HOSE CONNECTION, ANTI SIPHON VACUUM BREAKER, FLUSH MOUNTED BOX AND DOOR, LOOSE KEY
OPERATED, CHROME FINISH.
- 3/4 -
MV MIXING VALVE - LEONARD THERMOSTATIC, 1 GPM MIN. FLOW, WITH DIAL THERMOMETER, ADJUSTABLE HIGH TEMPERATURE LIMIT, 5 GPM AT 5 PSI LOSS, 125 PSI OPERATING PRESSURE. - 3/4 3/4
NOTES:
1. WATER SUPPLY TAPPING TO EACH FIXTURE SHALL BE FULL SIZE.
2. PROVIDE WATER HAMMER ARRESTORS ON HOT & COLD WATER SUPPLY BRANCHES SERVING SINGULAR, MULTIPLE OR GROUPS OF PLUMBING FIXTURES. ADHERENCE TO THE PLUMBING AND DRAINAGE INSTITUTE
STANDARD P.D.I.-WH201 (PER SPECIFICATIONS) SHALL BE EMPLOYED IN DETERMINING PROPER SIZE, SELECTION, PLACEMENT, LOCATION AND INSTALLATION OF ARRESTORS.
3. MOUNT PLUMBING FIXTURES LABELED "ABA" IN ACCORDANCE WITH ABA REQUIREMENTS.
COORDINATE WITH ARCHITECTURAL DRAWINGS.
4. SEE ARCHITECTURAL FOR FIXTURE MOUNTING HEIGHTS.
5. PROVIDE FIXTURES WITH ALL APPURTENANCES AS NECESSARY FOR A COMPLETE INSTALLATION.
HD HUB DRAIN - ZURN 2" FUNNEL DRAIN, WITH P-TRAP, LESS STRAINER, LESS CLEANOUT, COORDINATE OUTLET CONNECTION WITH PIPE TYPE. 2 - -
CONSULTING GROUP,INC.
WILLIAM JOSEPH JONES P.E.
FLORIDA LICENSE NUMBER 58080
901 W. Garden St. Pensacola, FL 32502
P: 850-438-0050 F: 850-432-8631
FLORIDA LICENSE NUMBER 05371
MECHANICAL ELECTRICAL STRUCTURAL
COMMUNICATIONS INDUSTRIAL
S C H M I D T
SCG PROJECT: 2018-129
A
SHEET
IDENTIFICATION
US Army Corps of
Engineers ®
Mobile District
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D E
S
IG
N E
D B
Y
B U
L L
O C
K T
IC
E
A S
S O
C
IA
T E
S
E
C
E R
V A
N T
E S
S T
R E
E T
S
U
IT
E B
P E
N S
A C
O L
A F
L O
R
ID
A
2 3 4 5
B
C
D
D R
A W
N B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
S
U E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
P R
O J E
C T
N U
M B
E R
F
IL
E N
A M
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E x
M O
B
IL
E D
IS
T
R
IC
T
S
A
IN
T J
O S
E P
H S
T R
E E
T
M O
B
IL
E A
L A
B A
M A
F T
F A
S O
F C
O M
B
IN
E D
S Q
U A
D O
P S
F A
C
IL
IT
Y
D
U K
E F
IE
L
D
D U
K E
F
IE
L D
F
L O
R
ID
A
P-002FTFA 163002
P L
U M
B
IN
G S
C H
E D
U L
E A
N D
N O
T E
S
C
P E
T E
R S
O N
C
P E
T E
R S
O N
C
D A
Y
W
J O
N E
S
-3
-2
M E
F
P
.D W
GW
-2
-R
-0
SUMP PUMP SCHEDULE
MARK
PERFORMANCE DATA ELECTRICAL DATA
CAPACITY
(GPM)
PUMP HEAD
(FT. W.C.)
MAX. SPEED
(RPM) MIN. HP VOLTS PHASE Hz
SP-1 50.0 20.0 3,450 1/2 120 1 60
NOTES:
1. PROVIDE SUBMERSIBLE SUMP PUMP.
2. PROVIDE WITH HIGH WATER AND OIL SENSING ALARMS, ALARM PANEL, AUDIBLE AND LIGHT
ALARMS WITH DRY CONTACTS, AND PLUG IN POWER CORD.
3. COORDINATE POWER REQUIREMENTS WITH ELECTRICAL.
4. ROUTE 2" PIPE TO LOCATION INDICATED ON PLANS.
NATURAL GAS DEMAND
EQUIPMENT DEMAND (CFH) QUANTITY DEMAND(CFH)
BOILER 950 1 950
WATER HEATER 120 1 120
TOTAL 1070
WATER HAMMER ARRESTOR SCHEDULE
P.D.I. SIZE FIXTURE UNITS SIZE
TYPE/MODEL NUMBER (WROUGHT
COPPER SHELL) NOTES
A 1-11 1/2" 75001-S 1,2
B 12-32 3/4" 75002-S 1,2
C 33-60 1" 75003-S 1,2
NOTES:
1. REPRESENTS PLUMBING AND DRAINAGE INSTITUTE "STANDARD P.D.I.-WH201".
2. REPRESENTS ARRESTOR TYPE AND ASSOCIATED MODEL NUMBER DERIVED FROM JOSAM CO.
(SHOCK ABSORBERS, WROUGHT COPPER SHELL) AND IS USED AS A STANDARD FOR HELPING
DETERMINE PROPER SELECTION FROM OTHER MANUFACTURERS EQUALLY COMPETENT IN THE
FABRICATION OF AND USING THE SIZING METHOD ESTABLISHED IN ACCORDANCE WITH
PLUMBING DRAINAGE INSTITUTE (P.D.I.).
RECIRCULATION PUMP SCHEDULE
MARK SERVICE TYPE
PERFORMANCE DATA ELECTRICAL DATA
CAPACITY -
GPM
PUMP HEAD
(FT. W.C.) MIN. EFF (%)
MAX. SPEED
(RPM) MIN. HP VOLTS PHASE Hz
CP-1 HOT WATER RECIRC. IL 6.0 26.0 50% 3,450 1/6 120 1 60
NOTES:
1. IL - INLINE 3. COORDINATE POWER REQUIREMENTS WITH ELECTRICAL.
2. PUMP SHALL HAVE 200 PSI MAX. WORKING PRESSURE. 4. MATERIAL OF CONSTRUCTION SHALL BE BRONZE.
GAS WATER HEATER SCHEDULE
WATER HEATER RATINGS
FUEL TYPE
COMBUSTION
CONTROL
ELECTRICAL DATA
CAPACITY
(GALLON)
MIN. GAS CONSUMPTION
INPUT(CFH) MIN. OUTPUT (MBH) EFFICIENCY
RECOVERY @ 100
DEG F RISE VOLTS PHASE Hz
GWH-1 60 120.0 114.0 95% 138 NATURAL GAS MODULATING 120 1 60
NOTES:
1. PROVIDE GAS FIRED WATER HEATER WITH MODULATING CAPACIBILITY.
2. COORDINATE POWER REQUIREMENTS WITH ELECTRICAL.
3. PROVIDE WATER HEATER WITH CONDENSATE NEUTRALIZATION KIT AND ROUTE CONDENSATE TO FLOOR DRAIN.
4. INSTALL UNIT AND ITS ACCESSORIES AS PER MFG RECOMMENDATIONS.
5. PROVIDE 4" PVC CONCENTRIC VENT KIT AND STAINLESS STEEL SIDEWALL TERMINATION KIT.
6. WATER HEATER SHALL HAVE SEAMLESS ASME TANK CONSTRUCTION, GLASS LINED WATER SIDE SURFACES. 160 PSI WORKING PRESSURE.
7. WATER HEATER SHALL MEET THE THERMAL EFFICIENCY AND/OR STANDBY LOSS REQUIREMENTS OF THE U.S. DEPARTMENT OF ENERGY AND CURRENT EDITION OF ASHRAE/IESNA 90.1.
8. WATER HEATER SHALL BE CERTIFIED BY UNDERWRITERS LABORATORIES (UL), INC. ACCORDING TO ANSI Z21.10.3. - CSA 4.3 STANDARDS.
9. PROVIDE WITH CSA CERTIFIED AND ASME RATED T&P RELIEF VALVES.
10. PROVIDE WITH GAS PRESSURE REGULATOR.
ABOVE GROUND GAS PIPING NOTES
FABRICATE AND INSTALL GAS SYSTEMS IN ACCORDANCE WITH NFPA 54 "NATIONAL FUEL GAS CODE", 2015 INTERNATIONAL BUILDING CODE, AND
WITH LOCAL GAS UTILITY COMPANY REQUIREMENTS AND STANDARDS.
SUBMIT MANUFACTURER'S TECHNICAL PRODUCT DATA AND INSTALLATION INSTRUCTIONS FOR GAS SYSTEMS PRODUCTS.
SUBMIT MAINTENANCE DATA AND PARTS LISTS FOR GAS SYSTEMS MATERIALS AND PRODUCTS. INCLUDE THIS DATA, PRODUCT DATA, SHOP
DRAWINGS, AND RECORD DRAWINGS IN MAINTENANCE MANUAL.
PROVIDE PIPING MATERIALS AND FACTORY-FABRICATED PIPING PRODUCTS OF SIZES, TYPES, PRESSURE RATINGS, AND CAPACITIES AS INDICATED. WHERE NOT INDICATED, PROVIDE PROPER SELECTION AS DETERMINED BY INSTALLER TO COMPLY WITH INSTALLATION REQUIREMENTS. PROVIDE MATERIALS AND PRODUCTS COMPLYING WITH NFPA 54 WHERE APPLICABLE; BASE PRESSURE RATING ON GAS PIPING SYSTEM MAXIMUM DESIGN PRESSURES. PROVIDE SIZES AND TYPES MATCHING PIPING AND EQUIPMENT CONNECTIONS; PROVIDE FITTINGS OF MATERIALS WHICH MATCH PIPE MATERIALS USED IN NATURAL GAS SYSTEMS. WHERE MORE THAN ONE TYPE OF MATERIALS OR PRODUCTS ARE INDICATED, SELECTION IS INSTALLER'S OPTION. PROVIDE IDENTIFICATION AND PAINT GAS PIPING YELLOW.
ALL GAS PIPING UNDER THIS CONTRACT SHALL BE BLACK STEEL PIPE; SCHEDULE 40; MALLEABLE IRON THREADED FITTINGS.
PROVIDE AND INSTALL PIPING SPECIALTIES IN ACCORDANCE WITH THE PIPE ESCUTCHEONS, DIELECTRIC UNIONS, PIPE SLEEVES, AND SLEEVE
SEALS. PROVIDE AND INSTALL SUPPORTS AND ANCHORS.
PROVIDE AGA APPROVED SPECIAL VALVES REQUIRED FOR GAS SYSTEMS INCLUD-ING THE FOLLOWING TYPES:
1. GAS COCKS 2" AND SMALLER: 150 PSI NON-SHOCK WOG, BRONZE STRAIGHTWAY COCK, FLAT OR SQUARE HEAD, THREADED ENDS.
2. WRENCHES: PROVIDE OPERATING WRENCHES FOR ALL GAS COCKS SERVING BOILERS.
3. ACCEPTABLE PRODUCERS FOR GAS COCKS: DEZURIK, JENKINS BROS., LUNKEN-HEIMER, NIBCO, POWELL, STOCKHAM, WALWORTH, ROCKWELL.
4. MASTER GAS CONTROL VALVE: BRONZE OR ALUMINUM BODY, PACKLESS, SINGLE SEAT, SUITABLE FOR FUEL GAS, SOLENOID OPERATED, NORMALLY OPEN, UL-APPROVED, MANUAL RESET, 24 VOLT DC. THE VALVE TO CLOSE WHEN DE-ENERGIZED BY THE FACP. ACCEPTABLE
PRODUCER: AUTOMATIC SWITCH CO., BULLETIN 8044, OR APPROVED EQUAL.
GAS REGULATORS
1. FIRST STAGE REGULATORS: PROVIDE UL LISTED FIRST STAGE (HIGH PRESSURE) REGULATORS. SEE PLANS FOR PRESSURE
REQUIREMENTS.
2. SECOND STAGE REGULATORS: PROVIDE UL LISTED SECOND STAGE ADJUSTABLE REGULATORS WITH INTEGRAL RELIEF VALVES. SEE
PLANS FOR PRESSURE REQUIREMENTS.
3. ACCEPTABLE PRODUCERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE REGULATORS BY REGO, OR APPROVED EQUAL.
4. GAS METER AND REGULATOR: PROVIDED BY LOCAL UTILITY COMPANY.
5. EXAMINE AREAS AND CONDITIONS UNDER WHICH GAS SYSTEMS, MATERIALS, AND PRODUCTS ARE TO BE INSTALLED. DO NOT PROCEED
WITH WORK UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED IN MANNER ACCEPTABLE TO INSTALLER. COORDINATE WITH
GAS SUPPLIER PRIOR TO STARTING WORK.
INSTALL GAS PIPING IN ACCORDANCE WITH DIVISION-23 BASIC MECHANICAL MATERIALS AND METHODS.
1. USE SEALANTS ON METAL GAS PIPING THREADS WHICH ARE CHEMICALLY RESISTANT TO GAS. USE SEALANTS SPARINGLY, AND APPLY TO
ONLY MALE THREADS OF METAL JOINTS.
2. REMOVE CUTTING AND THREADING BURRS BEFORE ASSEMBLING PIPING.
3. DO NOT INSTALL DEFECTIVE PIPING OR FITTINGS. DO NOT USE PIPE WITH THREADS WHICH ARE CHIPPED, STRIPPED OR DAMAGED. DO
NOT USE BUSHINGS IN THE GAS SYSTEM.
4. PLUG EACH GAS OUTLET, INCLUDING VALVES, WITH THREADED PLUG OR CAP IMMEDIATELY AFTER INSTALLATION AND RETAIN UNTIL
CONTINUING PIPING, OR EQUIPMENT CONNECTIONS ARE COMPLETED.
5. GROUND GAS PIPING ELECTRICALLY AND CONTINUOUSLY WITHIN PROJECT, AND BOND TIGHTLY TO GROUNDING CONNECTION.
6. INSTALL DRIPLEGS IN GAS PIPING WHERE INDICATED, AND WHERE REQUIRED BY CODE OR REGULATION.
7. INSTALL "TEE" FITTING WITH BOTTOM OUTLET PLUGGED OR CAPPED, AT BOTTOM OF PIPE RISERS.
8. USE DIELECTRIC UNIONS WHERE DISSIMILAR METALS ARE JOINED TOGETHER.
9. INSTALL PIPING WITH 1/64" PER FOOT (1/8%) DOWNWARD SLOPE IN DIRECTION OF FLOW.
10. INSTALL PIPING PARALLEL TO OTHER PIPING, BUT MAINTAIN MINIMUM OF 12" CLEARANCE BETWEEN GAS PIPING AND STEAM OR HYDRONIC
PIPING ABOVE 200°F.
VALVES INSTALLATION:
• GAS COCKS: PROVIDE AT CONNECTION TO GAS TRAIN FOR EACH GAS-FIRED EQUIPMENT ITEM; AND ON RISERS AND BRANCHES WHERE
INDICATED.
• LOCATE GAS COCKS WHERE EASILY ACCESSIBLE, AND WHERE THEY WILL BE PROTECTED FROM POSSIBLE INJURY.
• CONTROL VALVES: INSTALL AS INDICATED. REFER TO ELECTRICAL FOR WIRING; NOT WORK OF THIS SECTION.
• CONNECT GAS PIPING TO EACH GAS-FIRED EQUIPMENT ITEM, WITH DRIP LEG AND SHUTOFF GAS COCK. COMPLY WITH EQUIPMENT
MANUFACTURER'S INSTRUCTIONS.
GAS VENT INSTALLATION:
• INSTALL GAS VENTS FOR ALL DRAFT GAS-FIRED APPLIANCES IN ACCORDANCE WITH NFPA 54 AND THE MANUFACTURER'S INSTRUCTIONS.
• GAS VENTS SHALL TERMINATE AT LEAST 3 FEET ABOVE THE ROOF AND 2 FEET HIGHER THAN ANY PORTION OF A BUILDING WITHIN A
HORIZONTAL DISTANCE OF 10 FEET.
• MINIMUM VERTICAL GAS VENT LENGTH IS 5 FEET.
• SLOPE HORIZONTAL GAS VENT CONNECTORS UPWARD AT LEAST 1/4 INCH PER FOOT.
• INSPECT, TEST, AND PURGE GAS SYSTEMS IN ACCORDANCE WITH NFPA 54, LOCAL UTILITY REQUIREMENTS, AND AS PER SPECIFICATION
SECTION "TESTING, CLEANING AND STERILIZATION OF PIPING SYSTEMS".
CONSULTING GROUP,INC.
WILLIAM JOSEPH JONES P.E.
FLORIDA LICENSE NUMBER 58080
901 W. Garden St. Pensacola, FL 32502
P: 850-438-0050 F: 850-432-8631
FLORIDA LICENSE NUMBER 05371
MECHANICAL ELECTRICAL STRUCTURAL
COMMUNICATIONS INDUSTRIAL
S C H M I D T
SCG PROJECT: 2018-129
A
SHEET
IDENTIFICATION
US Army Corps of
Engineers ®
Mobile District
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D E
S
IG
N E
D B
Y
B U
L L
O C
K T
IC
E
A S
S O
C
IA
T E
S
E
C
E R
V A
N T
E S
S T
R E
E T
S
U
IT
E B
P E
N S
A C
O L
A F
L O
R
ID
A
2 3 4 5
B
C
D
D R
A W
N B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
S
U E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
P R
O J E
C T
N U
M B
E R
F
IL
E N
A M
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E x
M O
B
IL
E D
IS
T
R
IC
T
S
A
IN
T J
O S
E P
H S
T R
E E
T
M O
B
IL
E A
L A
B A
M A
F T
F A
S O
F C
O M
B
IN
E D
S Q
U A
D O
P S
F A
C
IL
IT
Y
D
U K
E F
IE
L
D
D U
K E
F
IE
L D
F
L O
R
ID
A
P-003FTFA 163002
P L
U M
B
IN
G S
C H
E D
U L
E S
C
P E
T E
R S
O N
C
P E
T E
R S
O N
C
D A
Y
W
J O
N E
S
-3
-2
M E
F
P
.D W
GW
-2
-R
-0
BREAKROOM
RESERVE SMA
PILOT RESERVE
FLIGHT ROOM
SUPPLY
AVIATION FLIGHT
EQUIPMENT
ARMS
TRAINING
FLIGHT
PLANNING
STAIRS
BRIEFING
BRIEFING
C O
R R
ID
O
R
MECHANICAL
COMM
ELEC
CORRIDOR
OPS DESK
STAIRS
JOINT USE
FIRST SGT
OPS OIC
COR…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .