RFQ_CDS250400_Roof_Replacement_-_Ingram_2421_NW_20th_Street_-_EXHIBIT_F-A000-Cover_sheet_Ingram_Header.pdf

PDF 925 KB Posted

Attached to
Roof Replacement - Ingram 2421 NW 20th Street
Solicitation number
RFQ# CDS/250400
Issued by
Marion County, Orlando City, Florida

About this file

This document is a construction drawing (A000 sheet) for a beam replacement project for the Ingram Residence located at 2421 NW 20th Street in Ocala, Florida, prepared by Rispoli Architects. The scope of work involves replacing an existing wood beam consisting of (2) 2x8s with like materials, including careful removal and reinstallation of decorative column wraps, installing new H1A hurricane ties at rafter connections, and replacing existing roof components. The project is designed under the Florida Building Code 2023 8th Edition and follows Type VB (unprotected & unsprinklered) construction for a residential R3 occupancy.

The drawing provides detailed technical specifications for the beam replacement, including maintaining existing structural wood posts, removing and replacing exterior ceiling elements, and reinstalling roof shingles. Specific instructions include using Simpson Strong-Tie hardware, temporary support/shoring during construction, and field verification of dimensions and existing conditions. The architectural plan is digitally signed and dated 01-24-25, with the project number RAA 2504, indicating a precise and professionally documented renovation approach for the residential property.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EXISTING SINGLE

STORY RESIDENCE

SCOPE OF

WORK

EXISTING COVERED ENTRY

26'-0" EXISTING CONCRETE SLAB

8'-6"8'-0"8'-6"

8"

4" (VERIFY)

E

X I S

T I N

G

C O

N C

R E

T E

S

L A

B

O H

EXISTING WOOD BEAM CONSISTING OF (2) 2X8S WITH

1X UNDER BEAM TO BE REPLACED WITH LIKE

MATERIALS. PROVIDE TEMPORARY SUPPORT/SHORING

AS REQUIRED; PROVIDE NEW H1A HURRICANE TIES BY

SIMPSON STRONG-TIE AT EACH RAFTER CONNECTION

(TYP)

CAREFULLY REMOVE EXISTING

DECORATIVE COLUMN WRAP

AROUND EXISTING 4X4 WOOD

POST. REINSTALL DECORATIVE

COLUMN WRAP AFTER BEAM

REPLACEMENT. STRUCTURAL

WOOD POST TO REMAIN IN

PLACE (TYP. 4)

A

GENERAL PAINTING NOTE:

FOR ALL NEW WOOD AND METAL SHALL BE SURFACE

PREPPED, PRIMED AND PAINTED WITH SHERWIN

WILLIAMS EXTERIOR SUPER PAINT, TYP. INSTALL IN

STRICT ACCORDANCE WITH MANUFACTURER'S

INSTRUCTIONS. ALSO PATCH OVER ALL JOINTS OR

SEAMS AND EXPOSED WOOD END GRAINS WITH

ELASTOMERIC KNIFE BLADE PATCHING COMPOUND.

EXISTING ALUMINUM WRAPPED 2X FASCIA BOARD TO REMAIN

EXISTING PRE-FINISHED ALUM. DRIP EDGE TO BE REMOVED

AND REPLACED WITH NEW

EL. 8'-0"

EXISTING BEARING HT.

(VERIFY)

CAREFULLY REMOVE EXISTING DECORATIVE COLUMN WRAP

AROUND EXISTING 4X4 WOOD POST. CLEAN, REPAINT AND

REINSTALL DECORATIVE COLUMN WRAP AFTER BEAM

REPLACEMENT. STRUCTURAL WOOD POST TO REMAIN IN PLACE

(TYP)

EXISTING SHINGLE ROOF TO BE REPLACED WITH NEW

DIMENSIONAL ASPHALT SHINGLES OVER GAF TIGERPAW

UNDERLAYMENT; INSPECT AND REPLACE DAMAGED EXISTING

PLYWOOD DECKING WITH NEW; NOTIFY OWNER AND

ARCHITECT IF SUBSTANTIAL DAMAGE IS FOUND

EXISTING PLYWOOD CEILING TO BE REMOVED AND REPLACED

WITH NEW PLYWOOD AND 1X BATTENS AT SEAMS; VERIFY IN

FIELD EXISTING SIZES/THICKNESSES

EXISTING WOOD BEAM CONSISTING OF (2) 2X8S

WITH 1X UNDER BEAM TO BE REPLACED WITH LIKE

MATERIALS. PROVIDE TEMPORARY

SUPPORT/SHORING AS REQUIRED; PROVIDE NEW

H1A HURRICANE TIES BY SIMPSON STRONG-TIE AT

EACH RAFTER CONNECTION (TYP)

EXISTING 4X4 STRUCTURAL WOOD

POST TO REMAIN (TYP)

NEW H1A HURRICANE TIE AT EACH RAFTER

REPLACE EXISTING 2X8X8 SQ COLUMN CAP TO

MATCH EXISTING (TYP; FIELD VERIFY)

REMOVE EXISTING STRAP AND PROVIDE NEW

LSTA12 STRAP BY SIMPSON STRONG TIE AT EACH

SIDE OF COLUMNS (TYP)

SCALE: 1/8" = 1'-0" (PRINTED @ 24X36)

A000

SHEET NO.

PROJECT NO.DRAWN

CHECKED DATE

AL

L R

IGH

TS

RE

SE

RV

ED

, TH

ES

E

PL

AN

S A

RE

PR

OT

EC

TE

D B

Y

CO

PY

RIG

HT

LA

W S.

UN

AU

TH

OR

IZE

D U

SE

M

AY

RE

SU

LT

IN

LEG

AL

AC

TIO

N.

CO

PY

RIG

HT

RE

VI

SI

O

N S

01-24-25

2504RAA

RAA

CO

N

ST

RU

CT

IO

N D

O

CU

M

EN

TS

SO

U

TH

M

AG

N

O

LI

A

AV

EN

U

E, O

CA

LA

, F

LO

RI

DA

(3

) 6

-0

W W

W .R

IS

PO

LI

AR

CH

IT

EC

T.

CO

M

JO

E@

RI

SP

O

LI

AR

CH

IT

EC

T.

CO

M

A

HE

AD

ER

R

EP

LA

CE

M

EN

T

FO

R:

TH

E

IN

G

RA

M

R

ES

ID

EN

CE

N

W

T

H S

T R

E E

T

O C

A L A

F

L O

R I D

A

JOSEPH A. RISPOLI, AIA

ARCHITECT, FL. LICENSE: AR95439

DIGITAL SIGNATURE

A BEAM REPLACEMENT FOR:

THE INGRAM

RESIDENCE

2421 NW 20TH STREET,

OCALA, FL 34475

INDEX OF DRAWINGS

SCOPE OF WORK

CODE REFERENCE

TYPE OF CONSTRUCTION (FBC CHAPTER 6): TYPE VB (UNPROTECTED & UNSPRINKLERED)

OCCUPANCY (FBC CHAPTER 3):

RESIDENTIAL - GROUP R3

A BEAM REPLACEMENT FOR INGRAM RESIDENCE, CONSISTING OF A NEW WOOD BEAM TO MATCH EXISTING, REPLACEMENT OF EXISTING EXTERIOR CEILING AND REPLACEMENT OF EXISTING ROOF SHINGLES.

LOCATION OF RESIDENCE IS 2421 NORTHWEST 20TH STREET, OCALA FLORIDA.

GENERAL CONDITIONS

A000 COVER, PROJECT INFORMATION, PLAN & DETAILS

APPLICABLE CODES:

FLORIDA BUILDING CODE 2023 8th EDITION

(BUILDING, PLUMBING, FUEL & GAS, MECHANICAL & ACCESSIBILITY VOLUMES)

NEC 2020 NATIONAL ELECTRICAL CODE

FFPC 2020 7th EDITION

ASCE 7-22 EDITION

KEY PLAN

SCALE: 3/8" = 1'-0" (PRINTED @ 24X36)

FLOOR PLAN - DIMENSIONS

SCALE: NTS = (PRINTED @ 11X17)

NOTE:

CONTRACTOR MUST FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS.

SCALE: NTS = (PRINTED @ 11X17)

SCALE: 3/4" = 1'-0" (PRINTED @ 24X36)

BEAM SECTION

SCALE: NTS = (PRINTED @ 11X17)

A

Sheets and Views
RESIDENTIAL NEW CODE
2025-02-05T09:12:09-0500
Joseph A Rispoli

File details come from the government source that posted it. Updated .