RFP Attachment 07 - CSDB Observations.pdf

PDF 168 KB Posted

Attached to
Sensor Beam 2024 - DRAFT RFP
Solicitation number
FA7037-23-R-0002
Issued by

View the file

Other files

File Type Posted
RFP Exhibit A - Professional Compensation Plan Model.xlsx XLSX spreadsheet
RFP Attachment 13 - Sensor Beam 2024 CDRL A001-A004 DD 1423s 29 Aug 2022.pdf PDF
RFP Attachment 12 - DRAFT DD Form 254_Redacted.pdf PDF
DRAFT Solicitation - FA703723R0002.pdf PDF
RFP Attachment 07 - CSDB Radar Tasking.pdf PDF
RFP Attachment 07 - CSDB Database Problem.MLT.pdf PDF
RFP Exhibit B - Labor Rate Model.xlsx XLSX spreadsheet
RFP Attachment 14 - DoD Checklist for Reviewing Subk Plans.pdf PDF
RFP Attachment 13 - Sensor Beam 2024 CDRL A013-A014 DD 1423s 29 Aug 2022.pdf PDF
RFP Attachment 13 - Sensor Beam 2024 CDRL A005-A008 DD 1423s 29 Aug 2022.pdf PDF
RFP Attachment 11 - Small Business Participation Commitment Document.pdf PDF
RFP Attachment 07 - CSDB Radar.pdf PDF
RFP Attachment 05 - 57 IS Proficiency Quiz.pdf PDF
RFP Attachment 02 - DRAFT_Section L.pdf PDF
RFP Attachment 13 - Sensor Beam 2024 CDRL A009-A012 DD 1423s 29 Aug 2022.pdf PDF
RFP Attachment 08 - Past Performance Information.pdf PDF
RFP Attachment 06 - USELMS Database Problem.pdf PDF
RFP Attachment 04 - Conformance Review Checklist.pdf PDF
RFP Attachment 01 - DRAFT SB 2024 PWS 3Feb2023.pdf PDF
RFP Attachment 03 - DRAFT _Section M.pdf PDF
RFP Attachment 10 - Total Overall Evaluated Price Worksheet.xlsx XLSX spreadsheet
RFP Attachment 09 - Past Performance Questionnaire.pdf PDF
Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RFP Attachment 07 – CSDB Observations

FA7037-23-R-0002

The following is a consolidation of reporting for 1000 observations of the system over a several month period of time.

Summary: The system operates in X Band between 9367 and 9490 MHz. PRIs range from 300 to 2010 usec. Constant and Jitter PRI modes have been seen. Pulse duration ranges from 0.03 usec to 1.2 usec. Scan period ranges from 1.5 to 2.7 seconds. ERP ranged from 57.5 to 66 dBW.

Analysis Details:

RF: The majority of the observations fall within 9400 to 9420 MHz with no clear peak value.

PD / PRI: The majority of observations fall into three bands of values. Additionally a longer Pulse Duration was seen on two occasions. The PRI/PD modes follow:

Pulse Duration (usec) Constant PRI (usec) Jitter PRI (usec)

0.03 – 0.35 330-690 300-720

0.4 – 0.6 950-1050 920-1080

0.7 – 0.9 1650 – 1850 1620-1880

1.2 300 n/a

Scan: The overall scan period ranges from 1.5 to 2.7 seconds. There majority of the observations fall at 2.5 sec.

ERP: Only 15 observations provided ERP data. This data appears to fall into two ranges, supporting employment of both antennas seen in manufacturer brochures.

ERP (dBm) Lower Range Upper Range

87.5 93.2

88.7 93.5

88.9 93.7

89.2 93.8

89.3 94.0 -- 96.0 (88.7 dBm avg) (93.0 dBm avg)