RFP 112-26 Addendum No1.pdf
PDF 349 KB Posted
- Attached to
- RFP 112-26 Centralized Train Control System
- Solicitation number
- BD-27-1206-40000-40000-132719
- Issued by
- Suffolk County, Massachusetts
About this file
This is Addendum No. 1 to RFP 112-26 issued by the Massachusetts Bay Transportation Authority (MBTA) on August 24, 2026, amending the Centralized Train Control System solicitation. The addendum substantially expands Section 2.5 from "Reserved" to comprehensive Information Security requirements and adds Section 3.19 Insurance requirements with Attachment C minimum insurance specifications. The addendum also replaces Form B, Item B4 Technical Response regarding Information Security with detailed technical questions requiring bidders to address system security planning, NIST SP 800-53 control tailoring for operational technology environments, role-based access control design integrated with enterprise identity providers, tamper-evident protection records, remote access and telemetry capabilities, critical vulnerability response procedures, failover and recovery mechanisms, incident containment strategies, security zone architecture compliance with TSA Security Directive 1580/82-2022-01, independent security assessments, and downstream data publishing without creating inbound paths to operational zones. The original RFP deadline of September 9, 2026 at 4:00 p.m. remains in effect with the pre-bid conference scheduled for August 26, 2026 at 11:00 a.m. via Microsoft Teams.
The Information Security requirements mandate compliance with TSA Cybersecurity Directives 1580/1582, NIST standards (SP 800-53 Rev. 5, SP 800-82 Rev. 3, SP 800-161, SP 800-218), CISA joint guidance on Zero Trust Principles for Operational Technology, and APTA rail transit security zone architecture standards. Critical requirements include IT/OT network segmentation, vital wayside signal system independence, persistent blocking protection that survives all failover and restore events with zero data loss, role-based access control with multi-factor authentication, continuous monitoring with 90-day online and 3-year archived retention, secure development lifecycle conformance to IEC 62443-4-1, pre-production independent penetration testing, and comprehensive Software Bill of Materials in SPDX 3.x, CycloneDX 1.7.x, or SWID formats with Vulnerability Exploitability Exchange documents. Recovery Time Objectives are specified at five minutes for core CTC dispatch functions and 24 hours for historical data, with Recovery Point Objectives of zero for protective-state data and one minute for operational state. All other terms of RFP 112-26 remain in effect.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Massachusetts Bay Transportation Authority Ten Park Plaza, Boston, MA 02116 mbta.com
August 24, 2026
Attention Bidder(s):
SUBJECT: RFP# 112-26 MBTA ENTRALIZED TRAIN CONTROL SYSTEM
Addendum No. 1
The MBTA is amending the following terms within RFP# 112-26:
1. Updating Section 2.5 from “Reserved” to “Information Secuity”:
Section 2.5 and all related subsections shall be amended in the following ways:
• Section 2.5, Information Security
These requirements apply to the complete delivered System: the CTC application, the Contractor-supplied network, the field operations tool, all interfaces and APIs, and all Contractor-supplied test, development, training, and simulation environments. The CTC System is safety-critical and supports Roadway Worker
Protection (RWP)
• Section 2.5.1 Standards and Compliance o 2.5.1.1 The Contractor shall review Agency-provided cybersecurity standards, policies, and procedures and shall either adhere to them or propose superior standards or design for MBTA acceptance.
o 2.5.1.2 Comply with TSA Cybersecurity Directives 1580/1582 series, as amended, including: IT/OT segmentation such that OT continues to operate if IT is compromised; access control; continuous monitoring and detection; timely remediation of exploitable systems; a tested incident response plan; and reporting of cybersecurity incidents to CISA within 24 hours.
o 2.5.1.3 Design to NIST SP 800-53 Rev. 5 (Moderate and High baselines, with OT tailoring as applied by MBTA), NIST SP 800-82 Rev. 3, NIST SP 800-161, NIST
SP 800-218, and the CISA joint guidance Adapting Zero Trust Principles to
Operational Technology (April 2026). Segment the network and build it from inherently secure components per the APTA rail transit security zone architecture recommended practice and IEC 62443-3-2, -3-3, -4-1, and -4-2. Where these differ from the Federal requirements above, the Federal requirements govern.
o 2.5.1.4 The Massachusetts Department of Public Utilities is the State Safety
Oversight Agency; cybersecurity conditions affecting safe operation are addressed as hazards under MBTA's safety plan. The state imposes no separate OT cybersecurity standard on this System. Applicability determinations are reserved to
MBTA.
o 2.5.1.5 Handle and protect all System information as Sensitive Security
Information (SSI) per 49 CFR Part 1520. Route all requests for network diagrams, configurations, or interface details through the MBTA Information Security team.
• Section 2.5.2 Safety and Worker Protection o 2.5.2.1 Vital wayside signal systems perform train protection independently of the
CTC and shall continue to do so. No System function shall override, bypass, suppress, or delay a vital wayside function. Loss or compromise of the System shall not create an unsafe condition or prevent local control at interlocking and bungalow locations.
o 2.5.2.2 Blocking protection and track authority are worker-protection functions and shall be treated as the System's highest-consequence functions. An applied block shall persist through loss of communications, control-center failover, component restart, and database restore. A block shall be cleared only by authenticated release by an authorized user — never automatically, by timeout, or as a side effect of recovery or restore. A blocking device applied to any switch, signal, track segment, or interlocking shall render that asset unusable until the block is removed (a functional interlock, not an advisory reminder).
o 2.5.2.3 Where protection cannot be confirmed, the System shall alarm and display an unknown protection state rather than the last known value. (A stale indication is more dangerous than none.)
o 2.5.2.4 Every block and track-authority action shall be attributable to a named user, time-stamped, and written to a tamper-evident record that no account can modify or delete.
o 2.5.2.5 The Contractor shall identify each function for which the System is the sole means of enforcing a protective condition, document its failure modes, and specify the means of maintaining protection when the System is unavailable
• Section 2.5.3 Architecture, Zones and Conduits o 2.5.3.1 Partition the System into security zones and conduits based on consequence of compromise, at minimum separating: the field/wayside interface (segmented per line), the CTC application, dispatcher operations, maintenance and engineering, and a data exchange zone. Submit the zone-and-conduit model and its risk assessment for MBTA acceptance before procuring any network or security equipment. The network shall permit authorized access from local and remote workstations and local and remote programming terminals.
o 2.5.3.2 The data exchange zone shall be the only zone permitted to communicate across the CTC boundary. All external interfaces and APIs shall terminate there, with the CTC pushing or publishing data outward to a server, replica, or broker rather than accepting inbound requests. Egress from the CTC zone shall be one-directional where feasible (data diode / unidirectional gateway, or a hardened
DMZ/broker). No downstream, analytics, or rider-facing system shall write to or command the CTC — directly or through any relay, proxy, tunnel, or shared credential — so that a compromised outside system reaches only a copy of the data and never the systems that move trains.
o 2.5.3.3 The Contractor shall document every conduit crossing a zone boundary:
ports, protocols, direction of flow, and the trust boundary it crosses. Where MBTA operates middleware between the CTC and other systems, the security boundary shall be specified explicitly and enforced at the CTC egress.
o 2.5.3.4 Interfaces to other MBTA control systems, including traction power
SCADA, shall be agreed with the owning organization before they are built.
Traction power energization state shall derive from the power system's own indications and shall display as unknown when the interface is degraded or of uncertain currency.
o 2.5.3.5 Wireless communication of any kind — Wi-Fi, radio, or cellular — is prohibited unless approved in writing by MBTA. State whether any existing wireless or cellular path at an MBTA field location will be used, shared, or depended on.
o 2.5.3.6 The field operations tool shall default to observation-only. Any control, blocking, or track-authority capability shall be identified separately in the proposal, enabled by MBTA per role, and capable of being disabled by MBTA without vendor involvement.
• Section 2.5.4 Application Programming Interfaces (API) o 2.5.4.1 The System shall expose documented APIs that allow MBTA to ingest external train location and position data — for example GPS/AVL light-rail data or an MBTA-built middleware feed — for visualization alongside native signal and track-circuit data. The System shall not require a source-specific implementation;
MBTA shall be able to publish conforming location data into the System without vendor involvement.
o 2.5.4.2 Externally ingested location and status data shall be treated as non-vital, advisory information. It shall not originate, modify, suppress, or influence any vital or protective function, and shall be visually distinguishable from signal-derived data.
o 2.5.4.3 Every API call shall be authenticated (OAuth 2.0 or mutual TLS). No hardcoded keys or shared static credentials shall be used; all secrets shall be rotatable and rotated on a defined schedule. Calls shall be authorized via RBAC and least privilege.
o 2.5.4.4 Command and write APIs shall be architecturally separated from read-only
APIs. Command/write capability shall never be exposed to downstream analytics, rider-facing, or lower-trust consumers; such consumers shall receive read-only data only, through the egress boundary/broker of Section 3.
o 2.5.4.5 All API traffic shall be encrypted in transit (TLS 1.2 or higher). All inputs shall be schema-validated to prevent injection or malformed commands from reaching the CTC.
o 2.5.4.6 APIs shall be rate-limited and throttled with per-consumer quotas to prevent denial-of-service of a safety-related system.
o 2.5.4.7 Every API call — especially write/command calls — shall be logged with caller identity and forwarded to MBTA's SIEM (Section 6).
o 2.5.4.8 The Contractor shall provide a documented API security specification (e.g., OpenAPI). All APIs shall be delivered through, and consumable only via, an
MBTA-controlled API gateway.
• Section 2.5.5 Access Control and Authentication o 2.5.5.1 All Contractor, subcontractor, and manufacturer remote access shall be through MBTA's approved zero trust network access (ZTNA) platform with multi-factor authentication, enabled per maintenance window and recorded; out-of-band paths are prohibited. Disclose every remote, diagnostic, telemetry, cloud, and call-home capability of every item supplied. No warranty or service-level obligation shall be conditioned on a remote connection.
o 2.5.5.2 Enforce multi-factor authentication on all interactive and administrative access. Provide role-based access control with least privilege and separation of duties, integrated with MBTA's enterprise identity provider and privileged access management (PAM) platform, including just-in-time elevation. Dispatching continuity shall not depend on an external authentication service.
o 2.5.5.3 Use unique named accounts only; shared or generic accounts are prohibited.
Enforce session timeout and re-authentication. All authentication and privilege-use events shall be logged and forwarded per Section 6.
o 2.5.5.4 Change or delete all default and vendor credentials before FAT, and deliver all administrative credentials to MBTA at acceptance.
• Section 2.5.6 Logging, Monitoring and Detection o 2.5.6.1 The System shall emit security-relevant logs — including authentication, privilege changes, configuration changes, integrity events, and communications anomalies — in a standard format (syslog / CEF).
o 2.5.6.2 Forward all security-relevant events to MBTA's SIEM or nominated collection point, retaining 90 days online and 3 years archived.
o 2.5.6.3 The System shall support OT-aware intrusion and anomaly detection and integration with MBTA's Security Operations Center (SOC) and continuous-monitoring program.
o 2.5.6.4 Provide secure, authenticated time synchronization (NTP) across all components so that events are accurately time-stamped and can be correlated.
• Section 2.5.7 Software Assurance, Hardening and Secure Development o 2.5.7.1 Harden all components before FAT to a per-device-class standard accepted by MBTA and to recognized hardening baselines (CIS Benchmarks / DISA STIGs) for all delivered operating systems and appliances: disable unnecessary services, ports, and interfaces; block unused USB and wireless module slots on field devices; and replace insecure management protocols. Deliver all configurations in native editable form, under version control, licensed in MBTA's name.
o 2.5.7.2 Deliver all software at a currently supported version; end-of-life software is not acceptable. Disclose components reaching end of support within five years, provide a software bill of materials (SBOM) and asset inventory, and support patching through the warranty period with a priced ten-year extension. No warranty shall be invalidated by MBTA applying a patch the Contractor has not identified in writing as incompatible within 30 days. Describe the version-control and update process by which the software will be kept current and prevented from reaching an end-of-life condition.
o 2.5.7.3 Provide evidence of a secure development lifecycle conforming to IEC
62443-4-1.
o 2.5.7.4 FAT and SAT shall include explicit security test cases. An independent penetration test / security assessment of the integrated system shall be conducted before production cutover, with remediation of all high and critical findings as a go-live gate.
• Section 2.5.8 Resilience, Backup and Recovery (RTO / RPO) o 2.5.8.1 Protective-state data — applied blocks, track authority, and the tamper-evident audit records of Section 2 — shall have a Recovery Point Objective of zero
(no data loss) and shall survive all failover, restart, and restore events. This is the
System's highest-priority recovery obligation and governs where it conflicts with any other objective below.
o 2.5.8.2 Core CTC / dispatch function shall meet a Recovery Time Objective of [≤ 5 minutes] via automated failover and an operational-state Recovery Point Objective of [≤ 1 minute].
o 2.5.8.3 Historical, playback, and log data shall meet a Recovery Time Objective of
[≤ 24 hours] and a Recovery Point Objective of [≤ 15 minutes].
o 2.5.8.4All backups and data extracts — including those used for playback, simulation, and training — shall have integrity verification and access control so that recovered or reused data cannot be tampered with.
o 2.5.8.5Demonstrate security controls, backup and restore, achievement of the
RTO/RPO above, and survival of applied blocking through failover and restore at both FAT and SAT.
• Section 2.5.9 Incident Response and Vendor Obligations o 2.5.9.1 The Contractor shall notify MBTA of any confirmed or suspected security incident affecting the product or any hosted component within [24–72 hours].
Vendor terms shall not delay MBTA's TSA obligation to report qualifying cybersecurity incidents to CISA within 24 hours.
o 2.5.9.2 The Contractor shall cooperate with MBTA and CISA incident response and shall preserve forensic evidence.
o 2.5.9.3 The Contractor shall support MBTA's Cybersecurity Incident Response
Plan exercises.
o 2.5.9.4 Service-level agreements shall address security incidents, not only availability outages, including response and remediation obligations for security events.
• Section 2.5.10 Supply Chain - Software Bill of Materials (SBOM) Requirements
The Supplier shall provide complete, accurate, and machine-readable SBOMs for all software, firmware, and embedded components delivered under this contract.
(SR-3 – Supply Chain Controls and Processes; SR-5 – Acquisition Strategies, Tools, and Methods; SA-4 – Acquisition Process). SBOM requirements apply to all TCS software, firmware, field devices, integration components, and containerized workloads that are provided by the selected bidder. (SR-3 – Supply
Chain Controls and Processes; SA-4 – Acquisition Process; SA-5 –
System/Services Documentation) o 2.5.10.1 Accepted SBOM Formats - SBOMs shall be provided in SPDX 3.x, CycloneDX 1.7.x+, SWID (or equivalent formats). (SA-4 – Acquisition Process;
SR-5 – Standardized Procurement Methods) o 2.5.10.2 Minimum SBOM Content Requirements - SBOMs shall include component identifiers, versions, dependencies, licensing, provenance, and build metadata. (SR-3 – Supply Chain Controls and Processes; SR-4 – Provenance; SI-7
– Software Integrity; SA-8 – Security Engineering Principles) o 2.5.10.3 Vulnerability Exploitability Exchange (VEX) - Supplier shall provide machine-readable VEX documents (or equivalent) identifying exploitability status
(affected, not affected, fixed, under investigation). (RA-5 – Vulnerability
Monitoring and Scanning; SI-2 – Flaw Remediation; IR-4 – Incident Handling;
SR-3 – Supply Chain Controls) o 2.5.10.4 SBOM Generation and Delivery Cadence - SBOMs shall be generated at build time, delivered with each release, updated quarterly, and refreshed within 48 hours of critical vulnerability discovery. (SA-10 – Developer Configuration
Management; SA-11 – Developer Testing and Evaluation; SA-15 – Development
Process; SR-6 – Supplier Reviews) o 2.5.10.5 Integrity, Signing, and Secure Development Attestation - SBOMs and
VEX (or equivalent) documents must be cryptographically signed and accompanied by attestation of conformance to secure development practices. (SI-7
– Software Integrity; SA-15 – Development Process, Standards & Tools; SA-3 –
SDLC; SA-18 – Tamper Resistance) o 2.5.10.6Ingestion & Interoperability Requirements - SBOMs must support automated ingestion, analysis, and integration with agency tooling. PDF-only SBOMs are not acceptable. (SA-4 – Acquisition Process; SR-5 – Standardized
Methods; PL-8 – Security Architecture) o 2.5.10.7 OT/ICS-Specific SBOM Requirements - SBOMs shall include firmware details, RTOS components, device-level drivers, and safety-certified component references for OT environments. (SR-4 – Provenance; SA-8 – Security Engineering
Principles; SI-7 – Software Integrity; RA-2 – Security Categorization) o 2.5.10.8Vulnerability Management Integration - Supplier shall map SBOM entries to vulnerability sources and support cybersecurity incident workflows. (RA-5 –
Vulnerability Monitoring; SI-2 – Flaw Remediation; IR-4 – Incident Handling; SR-
3 – Supply Chain Controls) o 2.5.10.9 Maintenance and Updates - SBOM and VEX information must be kept current throughout the software lifecycle and updated for component or vulnerability changes. (SR-6 – Supplier Assessments; SA-12 – Supply Chain
Protection; SI-2 – Flaw Remediation) o 2.5.10.10 Access and Confidentiality - SBOMs and VEX artifacts shall be shared with the Agency and security partners; essential component data may not be withheld. (AC-6 – Least Privilege; MP-4 – Media Protection; PL-2 – Security
Planning; SA-4 – Acquisition Process)
2. Adding Section 3.19 “Insurance”:
Adding Attachment C – Minimum Insurance Requirements
3. Updating Section: Form B: Technical Response, Item B4 “Information Security”:
Section Form B: Technical Response, Item B4-Information Security shall be replaced with the following:
a. Provide a redacted System Security Plan (SSP) from a comparable control system deployment.
Describe how you would develop and maintain the SSP for this System: how you define the authorization boundary, how controls are allocated among your system, inherited MBTA services (identity provider, remote access platform, and monitoring), and MBTA-owned responsibilities, and how the SSP stays current through design changes and patches.
b. MBTA applies NIST SP 800-53 Revision 5 at the Moderate and High baselines with operational technology tailoring. Select a control that conflicts with safe dispatching, for example session termination (AC-12) or account lockout after unsuccessful logon attempts
(AC-7) on a dispatcher console and walk through how you would tailor it and what compensating controls you would document.
c. Describe your role-based access control design for dispatcher, supervisor, roadway worker in charge, maintainer, and administrator roles. How do you integrate with an enterprise identity provider and a privileged access management platform while guaranteeing that dispatching continues and remains individually attributable when the external authentication service is unreachable?
d. Blocking and track authority records must survive even a hostile administrator. Technically, how does your product prevent any account, including root and your own service accounts, from modifying or deleting a protection record, and how would you prove to MBTA that a record has not been altered?
e. Identify every remote access, diagnostic, telemetry, licensing, update, cloud, and call-home capability that exists anywhere in the product set you are proposing, whether or not you intend to enable it. Then describe how you deliver and support your system for a customer who prohibits all vendor-initiated connectivity: how updates, license management, and warranty support work, and whether any warranty or service level commitment in your standard terms is conditioned on a remote connection.
f. Walk us through your most recent critical vulnerability response on a deployed system, from disclosure of a vulnerability with a Common Vulnerability Scoring System (CVSS) rating of
7.0 or higher or an entry in the Cybersecurity and Infrastructure Security Agency (CISA)
Known Exploited Vulnerabilities catalog, through to a tested patch position, on a system that cannot take a full outage. Describe your software bill of materials practice and how you verify firmware integrity independently of the delivery channel.
g. Describe the actual mechanism, not the policy, by which an applied block survives control center failover and a database restore from backup, and how the system presents restored protection state to the dispatcher. State the recovery time and recovery point objectives you would commit to per component, and how you would prove a bare-metal restore at Site
Acceptance Testing using only the media and documentation delivered to MBTA.
h. You detect anomalous traffic from a field interface device during revenue service. Walk through your response step by step: containment options that do not stop safe train movement, evidence preservation, and how you support MBTA's obligation to report cybersecurity incidents to CISA within 24 hours, recognizing that your notification to MBTA cannot wait for your investigation to finish.
i. Describe the security zone and conduit model you would propose for this System: the minimum zones you would establish, which zone is permitted to communicate outside the system boundary and what terminates there, and how your architecture satisfies Section III.B of
Transportation Security Administration (TSA) Security Directive 1580/82-2022-01 series (Rail
Cybersecurity Mitigation Actions and Testing), which requires network segmentation policies and controls designed to prevent operational disruption to the operational technology system if the information technology system is compromised. Describe how a web-based tool for field users would be served without creating a path into the zones that control operations. State the risk assessment method you use to decide the partitioning, and provide a redacted zone architecture from a comparable deployment.
j. Describe the most recent independent security assessment or penetration test performed against the product version you are proposing: who performed it, when, the most significant finding, and what changed in the product as a result. Then describe how you support customer-commissioned security testing, including penetration testing before revenue service, and your position on remediating findings attributable to your delivered system during the warranty period.
k. Describe the mechanism by which operational data is published to downstream and rider-facing consumers without creating any inbound path into the operational zones — where the publish boundary sits, whether unidirectional enforcement or a read-only DMZ store is used, and how a compromised consumer is prevented from affecting train movement. Provide a redacted integration architecture from a comparable deployment.
All other terms and conditions of RFP# 112-26 shall remain in effect.
Respectfully, Kiana Hall and Terunii Senevirratne
File details come from the government source that posted it. Updated .