DOM-IT Jessie Parker South Renovation - Addendum #03

This document is Addendum #03 issued on April 28, 2026, by the Iowa Department of Administrative Services for the DOM-IT Jessie Parker South Renovation project located at the Jessie Parker Building, 510 East 12th Street, Des Moines, Iowa. The addendum modifies and clarifies the original project drawings and specifications for a comprehensive renovation of approximately 53,729 square feet across a basement, Level 1, and Level 2 of an existing reinforced concrete framed building. The scope includes demolition and replacement of walls, flooring, ceilings, and mechanical, electrical, and plumbing systems. Addendum #03 replaces six specification sections (Table of Contents, Joint Sealants, Acoustical Ceilings, Tile Carpeting, Wall and Door Protection, and Window Shades) and revises fifteen architectural and mechanical/electrical drawing sheets to incorporate design clarifications and corrections identified through requests for information (RFI-2). Notable changes include removal of a bulkhead in Open Office/JS106, correction of graphic issues for glass walls, addition of existing floor drain details with instructions to replace caps and fill with leveler to be flush with floor surfaces, revision of VAV refurbishment notes to evaluation notes, and addition of door rough-in details for access control systems. The original bid deadline was April 30, 2026, at 2:00 PM with virtual bid opening at 3:30 PM via Google Meet. Construction is scheduled to commence on May 8, 2026, with substantial completion targeted for October 7, 2026.

The flooring package budget is estimated at $249,499.75. The project is divided into four separate bid packages: General Construction (BP 01), Flooring (BP 02), Electrical/Low Voltage/Fire Alarm (BP 03), and Mechanical/Plumbing (BP 04), with one additive alternate for thermostat replacement. Bidders are required to submit bid security equal to 5% of the total bid amount and must provide performance and payment bonds upon contract award. The contract will be executed on a ConsensusDOCS 802 form with modifications, and work must be coordinated through the Construction Manager, DCI Group. All work must comply with the 2024 International Building Code, 2024 International Existing Building Code, 2012 IECC, Iowa State Building Code, and applicable federal, state, and local regulations. The project is not subject to Davis-Bacon wage requirements, and work is exempt from Iowa sales tax. Contractors must maintain on-site supervision, provide daily cleanup, comply with Capitol Complex security procedures including background checks for personnel, and adhere to strict indoor air quality maintenance protocols for occupied facility construction. No specific contract award value is stated; however, the scope and complexity of the multi-phase, five-month renovation project with extensive MEP upgrades suggests a substantial contract value.

View the file

Other files

File Type Posted
RFB951800-01 - Addendum #04.pdf PDF
RFB951800-01 - Project Manual.pdf PDF
RFB951800-01 - Addendum #02.pdf PDF
RFB951800-01 - Addendum #01.pdf PDF
RFB951800-01 - Addendum #05.pdf PDF
RFB951800-01 - Bid Form.pdf PDF
RFB951800-01 - Drawings.pdf PDF
RFB951800-01 - Notice to Bidders.pdf PDF
RFB951800-01 - Addendum #01.pdf PDF
1383626-event.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Project #9518.00 Addendum #03 Page 1 of 38

Addendum #03 for RFB #951800-01

Project Name: DOM-IT Jessie Parker South Renovation

DAS RFB #: 951800-01

DAS Project: 9518.00

Date: April 28, 2026

Addendum #03:

This addendum is issued to modify, clarify, or amend the original Project Drawings and Specifications and is hereby made part of the Contract Documents. The Contractor shall be responsible for incorporating items in this Addendum to the Work. The following shall take precedence over anything to the contrary in the Drawings or Specifications. This addendum shall also supersede any previous addenda.

The receipt of this Addendum shall be acknowledged by inserting its number and date in the space provided on the

Bid Form.

This Addendum consists of:

General Items:

1. Addendum Pages (2 Pages)

2. 00 01 10 – Table of Contents (4 pages)

3. 07 92 00 – Joint Sealants (4 pages)

4. 09 51 00 – Acoustical Ceilings (4 pages)

5. 09 68 13 – Tile Carpeting (2 pages)

6. 10 26 00 – Wall and Door Protection (2 pages)

7. 12 24 00 – Window Shades (4 pages)

8. Drawings Sheets – A0.80, A0.81, A0.92, A1.00, A1.01, A1.02, A3.01, A3.02, A7.02, M201, M202, E230, E231, E232, E400 (15 Pages)

Changes to Specifications

1. Section 00 01 10 – Table of Contents

a. REPLACE original specification with the revised specification included in this addendum.

2. Section 07 92 00 – Joint Sealants

a. REPLACE original specification with the revised specification included in this addendum.

3. Section 09 51 00 – Acoustical Ceilings

a. REPLACE original specification with the revised specification included in this addendum.

4. Section 09 68 13 – Tile Carpeting

a. REPLACE original specification with the revised specification included in this addendum.

5. Section 10 26 00 – Wall and Door Protection

a. REPLACE original specification with the revised specification included in this addendum.

6. Section 12 24 00 – Window Shades

a. REPLACE original specification with the revised specification included in this addendum.

Changes to Drawings

1. A0.80 – DEMOLITION PLAN – LOWER LEVEL

a. REPLACE original sheet with the revised sheet included in this addendum.

i. Revises Door Hardware

2. A0.81 – DEMOLITION PLAN – LOWER LEVEL

a. REPLACE original sheet with the revised sheet included in this addendum.

i. Revises Demolition Keynote 13 (per RFI-2 Response)

3. A0.92 – REFLECTED CEILING DEMO PLAN – LEVEL 2

https://www.dcigroup-us.com/

Project #9518.00 Addendum #03 Page 2 of 38

a. REPLACE original sheet with the revised sheet included in this addendum.

i. Corrects graphic issue for south glass wall of Office/232.

4. A1.00 – FLOOR PLAN – LOWER LEVEL

a. REPLACE original sheet with the revised sheet included in this addendum.

i. Add existing floor drain and cleanout to Records/012.

5. A1.01 – FLOOR PLAN –LEVEL 1

a. REPLACE original sheet with the revised sheet included in this addendum.

i. Add existing floor drain and cleanout to IT Staff/JS016.

ii. Add New Construction Keynotes 25 to read “Existing floor drain. Replace cap, fill w/ leveler to be flush with floor surface.

6. A1.02 – FLOOR PLAN –LEVEL 2

a. REPLACE original sheet with the revised sheet included in this addendum.

i. Add New Construction Keynotes 25 to read “Existing floor drain. Replace cap, fill w/ leveler to be flush with floor surface.

7. A3.01 – REFLECTED CEILING PLAN – LEVEL 1

a. REPLACE original sheet with the revised sheet included in this addendum.

i. Removes bulkhead from Open Office/JS106 (per RFI-2 Response).

8. A3.02 – REFLECTED CEILING PLAN – LEVEL 2

a. REPLACE original sheet with the revised sheet included in this addendum.

i. Corrects graphic issue for south glass wall of Admin/JS217.

9. A7.02 - Schedules

a. REPLACE original sheet with the revised sheet included in this addendum.

i. Add New Construction Keynotes 25 to read “Existing floor drain. Replace cap, fill w/ leveler to be flush with floor surface.

10. M201 – Level 1 Plan - Mechanical

a. REPLACE original sheet with the revised sheet included in this addendum.

i. Revises VAV refurbishment note to an evaluation note.

11. M202 – Level 2 Plan - Mechanical

a. REPLACE original sheet with the revised sheet included in this addendum.

i. Revises VAV refurbishment note to an evaluation note.

12. E230 – Lower Level Floor Plan - Systems

a. REPLACE original sheet with the revised sheet included in this addendum.

i. Adds Keynote #1.

13. E231 – Level 1 Floor Plan - Systems

a. REPLACE original sheet with the revised sheet included in this addendum.

i. Adds Keynote #4.

14. E232 – Level 2 Floor Plan - Systems

a. REPLACE original sheet with the revised sheet included in this addendum.

i. Adds Keynote #2.

15. E400 – Electrical Details

a. REPLACE original sheet with the revised sheet included in this addendum.

i. Adds Door Rough-in Detail.

Questions and Answers:

Q1. What is the estimated valuation of the Flooring package?

A1. Flooring package budget is estimated at $249,499.75.

https://www.dcigroup-us.com/

9518.00 TABLE OF CONTENTS 00 0110 - 1

SECTION 00 0110

TABLE OF CONTENTS

PROCUREMENT AND CONTRACTING REQUIREMENTS

DIVISION 00 -- PROCUREMENT AND CONTRACTING REQUIREMENTS

00 0101 - Project Title Page 00 0107 - Seals Page 00 0110 - Table of Contents 00 0115 - List of Drawing Sheets 00 0116 - Bid Submittal Checklist 00 0113 - Notice to Bidders 00 2113 - Instructions to Bidders 00 2113.01 - IMPACS Electronic Procurement System Instructions 00 2113.02 - Sample Contractor Certificate of Insurance 00 3113 - Preliminary Schedule 00 3126 - Existing Hazardous Material Information 00 3143 - Permit Application 00 4116 - Bid Form 00 4116.01 - Non Descrimination Clause Information 00 4116.02 - Targeted Small Business Information 00 4313 - Bid Security Forms 00 5200 - Agreement Form 00 6000 - Payment Bond and Performance Bond Forms

SPECIFICATIONS

DIVISION 01 -- GENERAL REQUIREMENTS

01 1200 - Contract Summary 01 1201 - Special Work Requirements 01 1202 - General Work Requirements 01 2500 - Substitution Procedures 01 2600 - Contract Modification Procedures 01 2900 - Payment Procedures 01 3100 - Project Management and Coordination 01 3100.01 - Web Based Construction Management 01 3200 - Construction Progress Documentation 01 3300 - Submittal Procedures 01 4000 - Quality Requirements 01 5000 - Temporary Facilities and Controls 01 6000 - Product Requirements 01 7300 - Execution 01 7700 - Closeout Procedures

DIVISION 02 -- EXISTING CONDITIONS

02 4100 - Demolition

DIVISION 03 -- CONCRETE

03 3511 - Concrete Floor Finishes

9518.00 TABLE OF CONTENTS 00 0110 - 2

DIVISION 04 -- MASONRY (NOT USED)

DIVISION 05 -- METALS

05 5000 - Metal Fabrications

DIVISION 06 -- WOOD, PLASTICS, AND COMPOSITES

06 1053 - Miscellaneous Rough Carpentry 06 4100 - Architectural Wood Casework

DIVISION 07 -- THERMAL AND MOISTURE PROTECTION

07 9200 - Joint Sealants

DIVISION 08 -- OPENINGS

08 1113 - Hollow Metal Doors and Frames 08 1416 - Flush Wood Doors 08 7100 - Door Hardware

DIVISION 09 -- FINISHES

09 2116 - Gypsum Board Assemblies 09 3000 - Tiling 09 5100 - Acoustical Ceilings 09 6500 - Resilient Flooring 09 6813 - Tile Carpeting 09 9123 - Interior Painting

DIVISION 10 -- SPECIALTIES

10 2239 - Folding Panel Partitions

10 2600 - Wall and Door Protection

DIVISION 11 -- EQUIPMENT (NOT USED)

DIVISION 12 -- FURNISHINGS

12 2400 - Window Shades 12 3600 - Countertops

DIVISION 13 -- SPECIAL CONSTRUCTION (NOT USED)

DIVISION 14 -- CONVEYING EQUIPMENT (NOT USED)

DIVISION 21 -- FIRE SUPPRESSION (NOT USED)

DIVISION 22 -- PLUMBING

22 0500 - Basic Plumbing Requirements 22 0505 - Plumbing Demolition for Remodeling 22 0529 - Plumbing Supports and Anchors 22 0719 - Plumbing Piping Insulation 22 1000 - Plumbing Piping 22 1030 - Plumbing Specialties

9518.00 TABLE OF CONTENTS 00 0110 - 3

22 4000 - Plumbing Fixtures

DIVISION 23 -- HEATING, VENTILATING, AND AIR-CONDITIONING (HVAC)

23 0500 - Basic HVAC Requirements 23 0505 - HVAC Demoltion for Remodeling 23 0593 - Testing, Adjusting, and Balancing 23 0713 - Ductwork Insulation 23 3100 - Ductwork 23 3300 - Ductwork Accessories 23 3700 - Air Inlets and Outlets

DIVISION 25 -- INTEGRATED AUTOMATION (NOT USED)

DIVISION 26 -- ELECTRICAL

26 0500 - Basic Electrical Requirements 26 0505 - Electrical Demolition for Remodeling 26 0513 - Wire and Cables 26 0526 - Grounding and Bonding 26 0527 - Supporting Devices 26 0533 - Conduit and Boxes 26 0542 - Equipment Wiring Systems 26 0553 - Electrical Identification 26 0933 - Lighting Control Systems 26 2726 - Wiring Devices 26 5119 - LED Lighting

DIVISION 27 -- COMMUNICATIONS (NOT USED)

27 5119 - Sound Masking System

DIVISION 28 -- ELECTRONIC SAFETY AND SECURITY

28 3100 - Fire Alarm and Detection Systems

DIVISION 29 -- RESERVED (NOT USED)

DIVISION 30 -- RESERVED (NOT USED)

DIVISION 31 -- EARTHWORK (NOT USED)

DIVISION 32 -- EXTERIOR IMPROVEMENTS (NOT USED)

DIVISION 33 -- UTILITIES (NOT USED)

DIVISION 34 -- TRANSPORTATION (NOT USED)

DIVISION 40 -- PROCESS INTEGRATION (NOT USED)

END OF SECTION

This page intentionally left blank

9518.00 JOINT SEALANTS 07 9200 - 1

SECTION 07 9200

JOINT SEALANTS

PART 1 GENERAL

1.01 SECTION INCLUDES

A. Nonsag gunnable joint sealants.

B. Joint backings and accessories.

1.02 REFERENCE STANDARDS

A. ASTM C661 - Standard Test Method for Indentation Hardness of Elastomeric-Type Sealants by

Means of a Durometer; 2015 (Reapproved 2022).

B. ASTM C834 - Standard Specification for Latex Sealants; 2017 (Reapproved 2023).

C. ASTM C920 - Standard Specification for Elastomeric Joint Sealants; 2018 (Reapproved 2024).

D. ASTM C1193 - Standard Guide for Use of Joint Sealants; 2025.

E. ASTM C1330 - Standard Specification for Cylindrical Sealant Backing for Use with Cold Liquid-

Applied Sealants; 2023.

1.03 SUBMITTALS

A. See Section 01 3300 - Submittal Procedures for submittal procedures.

B. Product Data: Submit manufacturer's technical datasheets for each product to be used; include the following:

1. Physical characteristics, including movement capability, VOC content, hardness, cure time, and color availability.

2. List of backing materials approved for use with the specific product.

3. Backing material recommended by sealant manufacturer.

4. Substrates that product is known to satisfactorily adhere to and with which it is compatible.

5. Substrates the product should not be used on.

6. Installation instructions, including precautions, limitations, and recommended backing materials and tools.

7. Sample product warranty.

C. Product Data for Accessory Products: Submit manufacturer's technical data sheet for each product to be used, including physical characteristics, installation instructions, and recommended tools.

D. Color Cards for Selection: Where sealant color is not specified, submit manufacturer's color cards showing standard colors available for selection.

E. Samples for Verification: Where custom sealant color is specified, obtain directions from Architect and submit at least two physical samples for verification of color of each required sealant.

1.04 WARRANTY

A. See Section 01 7700 - Closeout Procedures for additional warranty requirements.

B. Manufacturer Warranty: Provide 2-year manufacturer warranty for installed sealants and accessories that fail to achieve a watertight seal, exhibit loss of adhesion or cohesion, or do not cure. Complete forms in Owner's name and register with manufacturer.

PART 2 PRODUCTS

2.01 MANUFACTURERS

A. Nonsag Sealants:

1. Bostik Inc: www.bostik-us.com/#sle.

2. Master Builders Solutions: www.master-builders-solutions.com/en-us/#sle.

9518.00 JOINT SEALANTS 07 9200 - 2

3. Pecora Corporation: www.pecora.com/#sle.

4. Sika Corporation: usa.sika.com/#sle.

5. Tremco Commercial Sealants & Waterproofing: www.tremcosealants.com/#sle.

6. W. R. Meadows, Inc: www.wrmeadows.com/#sle.

7. Or pre-approved equivalent.

2.02 JOINT SEALANT APPLICATIONS

A. Scope:

1. Interior Joints:

a. Do not seal gaps and openings in gypsum board and suspended ceilings

b. Do not seal through-penetrations in sound-rated assemblies that are also fire-rated assemblies.

c. Seal open joints except specific open joints indicated on drawings as not sealed.

d. Seal the following joints:

1) Joints between door frames and window frames and adjacent construction.

2) In sound-rated wall and ceiling assemblies, gaps at electrical outlets, wiring devices, and piping penetrations.

3) In sound-rated wall and ceiling assemblies, seal joints between wall assemblies and ceiling assemblies; between wall assemblies and other construction;

between ceiling assemblies and other construction.

B. Interior Joints: Use nonsag polyurethane sealant, unless otherwise indicated.

1. Wall and Ceiling Joints in Nonwet Areas: Acrylic emulsion latex sealant.

2. Wall and Ceiling Joints in Wet Areas: Nonsag polyurethane sealant for continuous liquid immersion.

3. Joints between Tile in Wet Areas and Floors, Walls, and Ceilings: Mildew-resistant silicone sealant.

4. In Sound-Rated Assemblies: Acrylic emulsion latex sealant.

C. Interior Wet Areas: Bathrooms, restrooms, and kitchens; fixtures in wet areas include plumbing fixtures, countertops, cabinets, and other similar items.

D. Sound-Rated Assemblies: Walls and ceilings identified as STC-rated, sound-rated, or acoustical.

2.03 NONSAG JOINT SEALANTS

A. Mildew-Resistant Silicone Sealant: ASTM C920, Grade NS, Uses M and A; single component, mildew resistant; not expected to withstand continuous water immersion or traffic.

1. Color: As selected by architect from manufacturer's full line.

2. Products:

a. Pecora Corporation; Pecora 898 NST (Non-Staining Technology):

www.pecora.com/#sle.

b. Sika Corporation; Sikasil N Plus US: usa.sika.com/#sle.

c. Sika Corporation; Sikasil GP: usa.sika.com/#sle.

d. Or pre-approved equivalent.

B. Polyurethane Sealant: ASTM C920, Grade NS, Uses M and A; single or multi-component; not expected to withstand continuous water immersion or traffic.

1. Movement Capability: Plus and minus 35 percent, minimum.

2. Hardness Range: 20 to 35, Shore A, when tested in accordance with ASTM C661.

3. Color: To be selected by Architect from manufacturer's standard range.

4. Service Temperature Range: Minus 40 to 180 degrees F (Minus 40 to 82 degrees C).

5. Products:

a. Master Builders Solutions; MasterSeal NP1: www.master-builders-solutions.com/en-us/#sle.

b. Sika Corporation; Sikaflex NP 1: usa.sika.com/#sle.

c. Sika Corporation; Sikaflex NP 2: usa.sika.com/#sle.

9518.00 JOINT SEALANTS 07 9200 - 3

d. Tremco Commercial Sealants & Waterproofing; Dymonic 100:

www.tremcosealants.com/#sle.

e. Or pre-approved equivalent.

C. Polyurethane Sealant for Continuous Water Immersion: ASTM C920, Grade NS, Uses M and

A; single or multicomponent; explicitly approved by manufacturer for continuous water immersion; suitable for traffic exposure when recessed below traffic surface.

1. Movement Capability: Plus and minus 35 percent, minimum.

2. Water Compatibility: Non-Potable.

3. Hardness Range: 20 to 35, Shore A, when tested in accordance with ASTM C661.

4. Color: To be selected by Architect from manufacturer's standard range.

5. Service Temperature Range: Minus 40 to 180 degrees F (Minus 40 to 82 degrees C).

6. Products:

a. Sika Corporation; Sikaflex NP 1: usa.sika.com/#sle.

b. Sika Corporation; Sikaflex NP 2: usa.sika.com/#sle.

c. Or pre-approved equivalent.

D. Acrylic Emulsion Latex: Water-based; ASTM C834, single component, nonstaining, nonbleeding, nonsagging; not intended for exterior use.

1. Color: To be selected by Architect from manufacturer's standard range.

2. Grade: ASTM C834; Grade 0 Degrees F (Minus 18 Degrees C).

3. Products:

a. Pecora Corporation; AC-20 +Silicone: www.pecora.com/#sle.

b. Tremco Commercial Sealants & Waterproofing; Tremflex 834:

www.tremcosealants.com/#sle.

c. Or pre-approved equivalent.

2.04 ACCESSORIES

A. Sealant Backing Materials, General: Materials placed in joint before applying sealants; assists sealant performance and service life by developing optimum sealant profile and preventing three-sided adhesion; type and size recommended by sealant manufacturer for compatibility with sealant, substrate, and application.

B. Sealant Backing Rod, Closed-Cell Type:

1. Cylindrical flexible sealant backings complying with ASTM C1330 Type C.

2. Size: 25 to 50 percent larger in diameter than joint width.

C. Backing Tape: Self-adhesive polyethylene tape with surface that sealant will not adhere to and recommended by tape and sealant manufacturers for specific application.

D. Masking Tape: Self-adhesive, nonabsorbent, nonstaining, removable without adhesive residue, and compatible with surfaces adjacent to joints and sealants.

E. Joint Cleaner: Noncorrosive and nonstaining type, type recommended by sealant manufacturer; compatible with joint forming materials.

F. Primers: Type recommended by sealant manufacturer to suit application; nonstaining.

PART 3 EXECUTION

3.01 EXAMINATION

A. Verify that joints are ready to receive work.

B. Verify that backing materials are compatible with sealants.

C. Verify that backer rods are of the correct size.

3.02 PREPARATION

A. Remove loose materials and foreign matter that could impair adhesion of sealant.

B. Clean joints, and prime as necessary, in accordance with manufacturer's instructions.

C. Perform preparation in accordance with manufacturer's instructions and ASTM C1193.

9518.00 JOINT SEALANTS 07 9200 - 4

D. Mask elements and surfaces adjacent to joints from damage and disfigurement due to sealant work; be aware that sealant drips and smears may not be completely removable.

3.03 INSTALLATION

A. Install this work in accordance with sealant manufacturer's requirements for preparation of surfaces and material installation instructions.

B. Provide joint sealant installations complying with ASTM C1193.

C. Measure joint dimensions and size joint backers to achieve width-to-depth ratio, neck dimension, and surface bond area as recommended by manufacturer, except where specific dimensions are indicated.

D. Install bond breaker backing tape where backer rod cannot be used.

E. Install sealant free of air pockets, foreign embedded matter, ridges, and sags, and without getting sealant on adjacent surfaces.

F. Do not install sealant when ambient temperature is outside manufacturer's recommended temperature range, or will be outside that range during the entire curing period, unless manufacturer's approval is obtained and instructions are followed.

G. Nonsag Sealants: Tool surface concave, unless otherwise indicated; remove masking tape immediately after tooling sealant surface.

3.04 POST-OCCUPANCY

A. Post-Occupancy Inspection: Perform visual inspection of entire length of project sealant joints at a time that joints have opened to their greatest width, i.e., at low temperature in thermal cycle. Report failures immediately and repair them.

9518.00 ACOUSTICAL CEILINGS 09 5100 - 1

SECTION 09 5100

ACOUSTICAL CEILINGS

PART 1 GENERAL

1.01 SECTION INCLUDES

A. Suspended metal grid ceiling system.

B. Acoustical units.

C. Supplementary insulation above ceiling.

1.02 REFERENCE STANDARDS

A. ASTM A653/A653M - Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-

Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process; 2025a.

B. ASTM C635/C635M - Standard Specification for Manufacture, Performance, and Testing of

Metal Suspension Systems for Acoustical Tile and Lay-in Panel Ceilings; 2022.

C. ASTM E1264 - Standard Classification for Acoustical Ceiling Products; 2023.

1.03 SUBMITTALS

A. See Section 01 3300 - Submittal Procedures for submittal procedures.

B. Shop Drawings: Indicate grid layout and related dimensioning.

C. Product Data: Provide data on suspension system components and acoustical units.

D. Samples: Submit two samples 6 by 6 inch (120 by 120 mm) in size illustrating material and finish of acoustical units.

PART 2 PRODUCTS

2.01 MANUFACTURERS

A. Acoustic Tiles/Panels:

1. Armstrong World Industries, Inc: www.armstrongceilings.com/#sle.

2. USG Corporation: www.usg.com/#sle.

3. Or pre-approved equivalent.

2.02 PERFORMANCE REQUIREMENTS

2.03 ACOUSTICAL UNITS

A. Acoustical Panels, Type ACT-1: Painted mineral fiber, with the following characteristics:

1. Classification: ASTM E1264 Type A.

a. Form: A1.4, cast or molded.

b. Pattern: E - lightly textured.

2. Size: 24 by 24 inches (610 by 610 mm).

3. Thickness: 3/4 inch (19 mm).

4. Light Reflectance: 84 percent, in accordance with ASTM E1264.

5. Noise Reduction Coefficient (NRC) Range: .70 to .90, in accordance with ASTM E1264.

6. Ceiling Attenuation Class (CAC): 36, in accordance with ASTM E1264.

7. Panel Edge: Shadowline Bevel.

8. Color: White.

9. Suspension System: Exposed grid.

10. Products:

a. Armstrong World Industries, Inc; Dune: www.armstrongceilings.com/#sle.

b. Basis of Design: USG Corporation; Frost 414 SLB Acoustical Panels:

www.usg.com/#sle.

c. Or pre-approved equivalent.

9518.00 ACOUSTICAL CEILINGS 09 5100 - 2

2.04 SUSPENSION SYSTEMS

A. Metal Suspension Systems - General: Complying with ASTM C635/C635M; die cut and interlocking components, with perimeter moldings, stabilizer bars, clips, and splices as required.

1. Materials:

a. Steel Grid: ASTM A653/A653M, G30 coating, unless otherwise indicated.

B. Exposed Suspension System: Hot-dip galvanized steel grid with steel cap.

1. Structural Classification: Intermediate-duty, when tested in accordance with ASTM C635/C635M.

2. Profile: Tee; 15/16 inch (24 mm) face width.

3. Finish: Baked enamel.

4. Color: White.

5. Products:

a. Armstrong World Industries, Inc; Prelude XL: www.armstrongceilings.com/#sle.

b. USG Corporation; Donn Brand DX 15/16 inch Acoustical Suspension System:

www.usg.com/#sle.

c. Or pre-approved equivalent.

2.05 ACCESSORIES

A. Support Channels and Hangers: Galvanized steel; size and type to suit application, seismic requirements, and ceiling system flatness requirement specified.

B. Hanger Wire: 12 gauge, 0.08 inch (2 mm) galvanized steel wire.

C. Perimeter Moldings: Same metal and finish as grid.

1. Size: As required for installation conditions.

2. Angle Molding: L-shaped, for mounting at same elevation as face of grid.

D. Acoustical Insulation: ASTM C665 friction fit type, unfaced batts.

1. Thickness: 2 inch (51 mm).

2. Size: To fit acoustical suspension system.

E. Touch-up Paint: Type and color to match acoustical and grid units.

PART 3 EXECUTION

3.01 EXAMINATION

A. Verify existing conditions before starting work.

B. Verify that layout of hangers will not interfere with other work.

3.02 PREPARATION

A. Install after major above-ceiling work is complete.

B. Coordinate the location of hangers with other work.

C. Provide hanger clips during steel deck erection. Provide additional hangers and inserts as required.

3.03 INSTALLATION - SUSPENSION SYSTEM

A. Rigidly secure system, including integral mechanical and electrical components, for maximum deflection of 1:360.

B. Lay out system to a balanced grid design with edge units no less than 50 percent of acoustical unit size.

C. Locate system on room axis according to reflected plan.

D. Perimeter Molding: Install at intersection of ceiling and vertical surfaces and at junctions with other interruptions.

1. Use longest practical lengths.

9518.00 ACOUSTICAL CEILINGS 09 5100 - 3

E. Suspension System, Non-Seismic: Hang suspension system independent of walls, columns, ducts, pipes and conduit. Where carrying members are spliced, avoid visible displacement of face plane of adjacent members.

F. Where ducts or other equipment prevent the regular spacing of hangers, reinforce the nearest affected hangers and related carrying channels to span the extra distance.

G. Do not support components on main runners or cross runners if weight causes total dead load to exceed deflection capability.

H. Support fixture loads using supplementary hangers located within 6 inches (152 mm) of each corner, or support components independently.

I. Do not eccentrically load system or induce rotation of runners.

3.04 INSTALLATION - ACOUSTICAL UNITS

A. Install acoustical units in accordance with manufacturer's instructions.

B. Fit acoustical units in place, free from damaged edges or other defects detrimental to appearance and function.

C. Fit border trim neatly against abutting surfaces.

D. Install acoustical units level, in uniform plane, and free from twist, warp, and dents.

E. Cutting Acoustical Units:

1. Make field cut edges of same profile as factory edges.

F. Lay acoustical insulation for a distance of 48 inches (1219 mm) either side of acoustical partitions.

3.05 TOLERANCES

A. Maximum Variation from Flat and Level Surface: 1/8 inch in 10 feet (3 mm in 3 m).

B. Maximum Variation from Plumb of Grid Members Caused by Eccentric Loads: 2 degrees.

3.06 CLEANING

A. See Section 01 7300 - Execution and 01 7700 - Closeout Procedures for additional requirements.

B. Clean surfaces.

C. Replace damaged or abraded components.

This page intentionally left blank

9518.00 TILE CARPETING 09 6813 - 1

SECTION 09 6813

TILE CARPETING

PART 1 GENERAL

1.01 SECTION INCLUDES

A. Carpet tile, fully adhered.

B. Removal of existing carpet tile.

1.02 REFERENCE STANDARDS

A. ASTM D2859 - Standard Test Method for Ignition Characteristics of Finished Textile Floor

Covering Materials; 2016 (Reapproved 2021).

B. ASTM F710 - Standard Practice for Preparing Concrete Floors to Receive Resilient Flooring;

2022.

C. CRI 104 - Standard for Installation of Commercial Carpet; 2018.

1.03 SUBMITTALS

A. See Section 013300 - Submittal Procedures for submittal procedures.

B. Product Data: Provide data on specified products, describing physical and performance characteristics; sizes, patterns, colors available, and method of installation.

C. Shop Drawings: Indicate layout of joints.

D. Samples: Submit two carpet tiles illustrating color and pattern design for each carpet color selected.

E. Accessory Samples: Submit two 6 inch (125 mm) long samples of edge strip and base cap.

F. Operation and Maintenance Data: Include maintenance procedures, recommended maintenance materials, and suggested schedule for cleaning.

1.04 FIELD CONDITIONS

A. Store materials in area of installation for minimum period of 24 hours prior to installation.

PART 2 PRODUCTS

2.01 MANUFACTURERS

A. Tile Carpeting:

1. Basis of Design: Shaw Contract; www.shawcontract.com; Simply By Nature, Offset Tile

5T296, Sterling Silver 84515, installed Ashlar.

2. Interface, Inc: www.interface.com/#sle.

3. Mohawk Group: www.mohawkgroup.com/#sle.

4. Or architect pre-approved equivalent.

2.02 MATERIALS

A. Tile Carpeting: Tufted, manufactured in one color dye lot.

1. Tile Size: 24 by 24 inch (61 by 61 mm), nominal.

2. Thickness: .253 inch (6.43 mm).

3. Surface Flammability Ignition: Pass ASTM D2859 (the "pill test").

4. Wear Rating as classified by ASTM D5252: Severe.

5. Maximum Electrostatic Charge: ____ Kv. at 20 percent relative humidity.

6. Gauge: 1/10 in (39.4 per 10 cm).

7. Stitches: 10 per inch (40.5 per 10 cm).

8. Tufted Weight: 16 oz/sq yd (542.5 gm/sq m).

9. Average Density: 4500 oz/yd3 (0.167 g/cm3)

10. Primary Backing Material: Synthetic.

11. Installation Method: Ashlar.

9518.00 TILE CARPETING 09 6813 - 2

2.03 ACCESSORIES

A. Subfloor Filler: White premix latex; type recommended by flooring material manufacturer.

B. Adhesives:

1. Compatible with materials being adhered; maximum VOC content of 50 g/L; CRI (GLP) certified; in lieu of labeled product, independent test report showing compliance is acceptable.

C. Carpet Tile Adhesive: Recommended by carpet tile manufacturer; releasable type.

PART 3 EXECUTION

3.01 EXAMINATION

A. Verify that subfloor surfaces are smooth and flat within tolerances specified for that type of work and are ready to receive carpet tile.

3.02 PREPARATION

A. Remove existing carpet tile.

B. Prepare floor substrates as recommended by flooring and adhesive manufacturers.

C. Remove subfloor ridges and bumps. Fill minor or local low spots, cracks, joints, holes, and other defects with subfloor filler.

D. Apply, trowel, and float filler to achieve smooth, flat, hard surface. Prohibit traffic until filler is cured.

E. Vacuum clean substrate.

3.03 INSTALLATION

A. Starting installation constitutes acceptance of subfloor conditions.

B. Install carpet tile in accordance with manufacturer's instructions.

C. Blend carpet from different cartons to ensure minimal variation in color match.

D. Cut carpet tile clean. Fit carpet tight to intersection with vertical surfaces without gaps.

E. Lay carpet tile in square pattern, with pile direction parallel to next unit, set parallel to building lines.

F. Locate change of color or pattern between rooms under door centerline.

G. Fully adhere carpet tile to substrate.

H. Trim carpet tile neatly at walls and around interruptions.

3.04 CLEANING

A. See Section 01 7300 - Execution and 01 7700 - Closeout Procedures for additional requirements.

B. Remove excess adhesive without damage, from floor, base, and wall surfaces.

C. Clean and vacuum carpet surfaces.

9518.00 WALL AND DOOR

PROTECTION 10 2600 - 1

SECTION 10 2600

WALL AND DOOR PROTECTION

PART 1 GENERAL

1.01 SECTION INCLUDES

A. Corner guards.

1.02 REFERENCE STANDARDS

A. ASTM D256 - Standard Test Methods for Determining the Izod Pendulum Impact Resistance of Plastics; 2024.

B. ASTM D543 - Standard Practices for Evaluating the Resistance of Plastics to Chemical Reagents; 2021.

C. ASTM F476 - Standard Test Methods for Security of Swinging Door Assemblies; 2023.

D. ASTM G21 - Standard Practice for Determining Resistance of Synthetic Polymeric Materials to

Fungi; 2015, with Editorial Revision (2021).

1.03 SUBMITTALS

A. See Section 01 3300 - Submittal Procedures for submittal procedures.

B. Product Data: Indicate physical dimensions, features, and anchorage details.

C. Samples: Submit samples illustrating component design, configurations, joinery, color and finish.

1. Submit two sections of corner guards, 24 inches (610 mm) long.

D. Warranty Documentation: Submit manufacturer warranty and ensure that forms have been completed in Owner's name and registered with manufacturer.

E. Maintenance Materials: Furnish the following for Owner's use in maintenance of project:

1. See Section 01 6000 - Product Requirements, for additional provisions.

2. Extra Stock Materials: One package(s) of minimum 96 inches (2438 mm) long unit of each kind of covers for corner guards.

1.04 DELIVERY, STORAGE, AND HANDLING

A. Deliver wall and door protection items in original, undamaged protective packaging. Label items to designate installation locations.

B. Protect work from moisture damage.

C. Protect work from UV light damage.

D. Do not deliver products to project site until areas for storage and installation are fully enclosed, and interior temperature and humidity are in compliance with manufacturer's recommendations for each type of item.

E. Store products in either horizontal or vertical position, in compliance with manufacturer's instructions.

1.05 WARRANTY

A. See Section 01 7800 - Closeout Submittals for additional warranty requirements.

B. Manufacturer Warranty: Provide 5-year manufacturer warranty for metal crash rails. Complete forms in Owner's name and register with manufacturer.

PART 2 PRODUCTS

2.01 MANUFACTURERS

A. Corner Guards:

1. Construction Specialties, Inc: www.c-sgroup.com/#sle.

9518.00 WALL AND DOOR

PROTECTION 10 2600 - 2

2. Inpro Corporation: www.inprocorp.com/#sle.

3. Koroseal Interior Products: www.koroseal.com/#sle.

4. Wallprotex: www.wallprotex.com/#sle.

5. Wolf-Gordon: www.wolfgordon.com/#sle.

6. Or architect pre-approved equivalent.

2.02 PERFORMANCE CRITERIA

A. Impact Strength: Unless otherwise noted, provide protection products and assemblies that have been successfully tested for compliance with applicable provisions of ASTM D256 and/or

ASTM F476.

B. Chemical and Stain Resistance: Unless otherwise noted, provide protection products and assemblies with chemical and stain resistance complying with applicable provisions of ASTM D543.

C. Fungal Resistance: Unless otherwise noted, provide protection products and assemblies which pass ASTM G21 testing.

2.03 PRODUCT TYPES

A. Corner Guards - Surface Mounted:

1. Material: High impact vinyl.

2. Thickness: 0.100 inch (2.5 mm).

3. Width of Wings: 2 inches (51 mm).

4. Corner: Square.

5. Color: As selected from manufacturer's standard colors.

6. Length: One piece, 48 inches (1219 mm).

7. Mounting: Clear adhesive.

2.04 FABRICATION

A. Fabricate components with tight joints, corners and seams.

PART 3 EXECUTION

3.01 EXAMINATION

A. Verify that field measurements are as indicated on drawings.

B. Verify that substrate surfaces for adhered items are clean and smooth.

1. Test painted or wall covering surfaces for adhesion in inconspicuous area, as recommended by manufacturer. Follow adhesive manufacturer's recommendations for remedial measures at locations and/or application conditions where adhesion test's results are unsatisfactory.

C. Start of installation constitutes acceptance of project conditions.

3.02 INSTALLATION

A. Install components in accordance with manufacturer's instructions, level and plumb, secured rigidly in position to supporting construction.

B. Position bottom of corner guard immediately above wall base.

3.03 TOLERANCES

A. Maximum Variation From Required Height: 1/8 inch (3 mm).

B. Maximum Variation From Level or Plane For Visible Length: 1/4 inch (6 mm).

3.04 CLEANING

A. Clean protection items of excess adhesive, dust, dirt, and other contaminants.

9518.00 WINDOW SHADES 12 2400 - 1

SECTION 12 2400

WINDOW SHADES

PART 1 GENERAL

1.01 SECTION INCLUDES

A. Interior manual roller shades.

1.02 REFERENCE STANDARDS

A. ASTM E2180 - Standard Test Method for Determining the Activity of Incorporated Antimicrobial Agent(s) in Polymeric or Hydrophobic Materials; 2024.

B. ASTM G21 - Standard Practice for Determining Resistance of Synthetic Polymeric Materials to Fungi; 2015, with Editorial Revision (2021).

C. NFPA 701 - Standard Methods of Fire Tests for Flame Propagation of Textiles and Films; 2023, with Errata.

D. UL 325 - Standard for Door, Drapery, Gate, Louver, and Window Operators and Systems;

Current Edition, Including All Revisions.

E. WCMA A100.1 - Standard for Safety of Window Covering Products; 2022.

1.03 ADMINISTRATIVE REQUIREMENTS

A. Preinstallation Meeting: Convene one week prior to commencing work related to products of this section; require attendance of affected installers.

B. Sequencing:

1. Do not fabricate shades until field dimensions for each opening have been taken with field conditions in place.

2. Do not install shades until final surface finishes and painting are complete.

1.04 SUBMITTALS

A. See Section 01 3300 Submittal Procedures, for submittal procedures.

B. Product Data: Provide manufacturer's standard catalog pages and data sheets, including materials, finishes, fabrication details, dimensions, profiles, mounting requirements, and accessories.

C. Shop Drawings: Include shade schedule indicating size, location and keys to details, head, jamb and sill details, mounting dimension requirements for each product and condition, and operation direction.

D. Selection Samples: Include fabric samples in full range of available colors and patterns.

E. Verification Samples: Minimum size 6 inches (150 mm) square, representing actual materials, color and pattern.

F. Manufacturer's Instructions: Include instructions for storage, handling, protection, examination, preparation, and installation of product.

G. Project Record Documents: Record actual locations of control systems and show interconnecting wiring.

H. Operation and Maintenance Data: List of all components with part numbers, sources of supply, and operation and maintenance instructions; include copy of shop drawings.

I. Warranty: Submit sample of manufacturer's warranty and documentation of final executed warranty completed in Owner's name and registered with manufacturer.

1.05 QUALITY ASSURANCE

A. Installer Qualifications: Company specializing in performing work of this type and a manufacturer's authorized representative.

9518.00 WINDOW SHADES 12 2400 - 2

1.06 MOCK-UP

A. Mock-Up: Provide full size mock-up of window shade system complete with selected shade fabric including example of seams and batten pockets when applicable.

1. Obtain Owner's approval of light and privacy characteristics of fabric prior to fabrication.

2. Full-sized mock-up may become part of the final installation.

1.07 DELIVERY, STORAGE, AND HANDLING

A. Deliver shades in manufacturer's unopened packaging, labeled to identify each shade for each opening.

B. Handle and store shades in accordance with manufacturer's recommendations.

1.08 FIELD CONDITIONS

A. Do not install products under environmental conditions outside manufacturer's absolute limits.

1.09 WARRANTY

A. See Section 01 7200 Execution and 01 7700 Closeout Procedures, for additional warranty requirements.

B. Provide manufacturer's warranty from Date of Substantial Completion, covering the following:

1. Shade Hardware: Five years.

2. Fabric: Five years.

3. Aluminum and Steel Coatings: Five years.

PART 2 PRODUCTS

2.01 MANUFACTURERS

A. Interior Manually Operated Roller Shades:

1. Hunter Douglas Architectural; RB500+ Manual Roller Shades:

www.hunterdouglasarchitectural.com/#sle.

2. Lutron Electronics Co., Inc; Contract Roller Manual Shades: www.lutron.com/#sle.

3. MechoShade Systems LLC; Mecho/5x System: www.mechoshade.com/#sle.

4. Or architect pre-approved equivalent.

2.02 ROLLER SHADES

A. General:

1. Provide shade system components that are easy to remove or adjust without removal of mounted shade brackets.

2. Provide shade system that operates smoothly when shades are raised or lowered.

B. Roller Shades:

1. Basis of Design: MechoShade Mecho/5x.

2. Description - Interior Roller Shades: Single roller, manually operated fabric window shade system complete with mounting brackets, roller tubes, hembars, hardware, and accessories.

a. Drop Position: Regular roll.

b. Roll Direction: Roll down, closed position is at window sill.

c. Mounting: Wall mounted.

d. Size: As indicated on drawings.

e. Fabric: As indicated under Shade Fabric article.

3. Brackets and Mounting Hardware: As recommended by manufacturer for mounting indicated and to accommodate shade fabric roll-up size and weight.

a. Material: Stamped steel.

4. Roller Tubes: As required for type of shade operation.

a. Material: Extruded aluminum, clear anodized finish.

b. Size: As recommended by manufacturer; selected for suitability for installation conditions, span, and weight of shades.

9518.00 WINDOW SHADES 12 2400 - 3

c. Fabric Attachment: Utilize extruded channel in tube to accept vinyl spline welded to fabric edge.

5. Hembars: Designed to maintain bottom of shade straight and flat.

a. Style: Exposed aluminum bottom bar, flat profile with closed ends; baked enamel finish, color to match shade fabric.

6. Accessories:

a. Fascia: Extruded aluminum, size as required to conceal shade mounting, attachable to brackets without exposed fasteners; baked enamel finish.

1) Color: Architect to select from manufacturer's full line.

2) Profile: Square.

3) Configuration: Captured; fascia stops at bracket end.

b. Fasteners: Noncorrosive, and as recommended by shade manufacturer.

2.03 SHADE FABRIC

A. Fabric for Light-Filtering Shades: Nonflammable, color-fast, impervious to heat and moisture, and able to retain its shape under normal operation.

1. Manufacturers:

a. MechoShade Systems LLC; ThermoVeil - 1000 Series (2-3% open):

www.mechoshade.com/#sle.

b. MechoShade Systems LLC; EcoVeil Screens - 1550 Series (3% open):

www.mechoshade.com/#sle.

c. Mermet Corporation; E-Screen - 3%: www.mermetusa.com/#sle.

d. Mermet Corporation; M-Screen - 3%: www.mermetusa.com/#sle.

e. Or architect pre-approved equivalent.

2. Material: Vinyl coated polyester.

3. Performance Requirements:

a. Flammability: Pass NFPA 701 large and small tests.

b. Fungal Resistance: No growth when tested in accordance with ASTM G21.

c. Antimicrobial Resistance: Greater than 95 percent reduction of bacteria when tested in accordance with ASTM E2180.

4. Roll Width: 78 inches (1981 mm) minimum.

5. Color: As selected by Architect from manufacturer’s full range of colors.

6. Fabrication:

a. Fabric Orientation: Railroaded, fabric is turned 90 degrees off the roll.

b. If height of opening requires multiple panels of railroaded fabric, use battens at seams.

c. Battens: Full width of shade.

2.04 ROLLER SHADE FABRICATION

A. Field measure finished openings prior to ordering or fabrication.

B. Dimensional Tolerances: Fabricate shades to fit openings within specified tolerances.

1. Vertical Dimensions: Fill openings from head to sill with 1/4 inch (6.5 mm) space between bottom bar and window stool.

2. Horizontal Dimensions - Inside Mounting: Provide symmetrical light gaps on both sides of shade not to exceed 1/2 inch (13 mm) total.

3. Horizontal Dimensions - Outside Mounting: Extend shades 2 inches (50 mm) beyond jambs on each side.

PART 3 EXECUTION

3.01 EXAMINATION

A. Examine finished openings for deficiencies that may preclude satisfactory installation.

B. If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding.

9518.00 WINDOW SHADES 12 2400 - 4

C. Start of installation shall be considered acceptance of substrates.

3.02 INSTALLATION

A. Install in accordance with manufacturer's instructions and approved shop drawings, using mounting devices as indicated.

B. Replace shades that exceed specified dimensional tolerances at no extra cost to Owner.

C. Adjust level, projection, and shade centering from mounting bracket. Verify there is no telescoping of shade fabric. Ensure smooth shade operation.

3.03 CLEANING

A. Clean soiled shades and exposed components as recommended by manufacturer.

B. Replace shades that cannot be cleaned to "like new" condition.

3.04 CLOSEOUT ACTIVITIES

A. See Section 01 7300 - Execution and 01 7700 - Closeout Procedures, for closeout submittals.

B. Demonstration: Demonstrate operation and maintenance of window shade system to Owner's personnel.

3.05 PROTECTION

A. Protect installed products from subsequent construction operations.

B. Touch-up, repair, or replace damaged products before Substantial Completion.

CG CG

CGCG

FD

FD

SC

SD

SE

SF

SG

SH

SB

S3S2S1 S5 S6 S7 S9 S12S11S10 S13

SA

S15

PLAN

NORTH

ELEVELEV

RECORDS

RECORDS

MOTHERS ROOM

ADM (CORNER GUARDS ADDED)

ADM

STUD PARTITION OR EXTERIOR CAVITY WALL -

REFER TO WALL TYPE SHEET FOR ADDITIONAL INFO

CMU WALL

EXISTING WALLS AND BUILDING ELEMENTS TO

REMAIN ARE DRAWN IN HALFTONE

CAST-IN-PLACE WALL

WALLS AND BUILDING ELEMENTS TO BE

DEMOLISHED ARE DRAWN WITH DASHED LINES

1t

PARTITION GRAPHICS / PHASING LEGEND

O P

N G

F L R

OPNG

4'-0" FLR

DEMOLISHED ELEMENTS SHOWN IN

PROJECTION ARE SURROUNDED BY DASHED

LINES AND FILLED WITH A DIAGONAL HATCH

Ph.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

B

A

C

D

E

F

G

H

J

K

L www.imegcorp.com

Des Moines, IA 50322

2822 106th Street

MEP Engineer

IMEG Corp.

515 334 9906

C op yr ig ht

S ub st an ce , L

LC

1300 Walnut Street, Suite 201 Des Moines, Iowa 50309 Ph. 515 243 4407 www.substancearchitecture.com

Revisions

Substance No.:

#9518

16 17 18

M

N

P

Date:

/2

/2

:1

:3

P M

A u to d e s k D o c s /0

-0

D

O M

-I T

J e s s ie

P a rk e r S o u th B u ild in g

R e n o v a ti o n

/D O

M -I

T J e s s ie

P a rk e r S o u th B ld g

R e n o

A R

C H

R

.r v t

D O

M -I

T D

O M

-I T

J e s s ie P a rk e r

S o u th

R e n o v a ti o n

D o c u m e n ts

A0.80

DEMOLITION PLAN - LOWER LEVEL

DOM-IT No.:

0719-01

April 10, 2026

SCALE: 1/8" = 1'-0"A1

LOWER LEVEL DEMOLITION PLAN

DEMOLITION KEYNOTES

KEY NOTE

1 DEMO WALL BASE. (FLOORING TO BE DEMO'D W/ ABATEMENT NIC)

2 DEMO CARPET TILE AND WALL BASE. PREP FOR NEW FLOORING AND

BASE.

3 DEMO WALL AS NEEDED FOR NEW DOOR AND FRAME. VERIFY NO MEPT

CONFLICTS.

4 DEMO FLOORING AND WALL BASE. PREP FOR NEW FLOORING AND

BASE.

5 DEMO WINDOW COVERING

6 DEMO WALL, WALL BASE, DOOR/WINDOW/FRAME, AND ALL DEVICES

(DEMO CABELING BACK TO NEAREST J-BOX TO REMAIN). SALVAGE

DOOR/WINDOW/FRAME AS NEEDED FOR BUILD-BACK. TYP.

7 DEMO HANDRAIL (CUT FLUSH W/ FLOOR), GRIND TO BE BELOW FLOOR

SURFACE, PATCH FLOOR SLAB TO BE FLUSH AND SMOOTH WITH

SURROUNDING SURFACE.

8 DEMO CASEWORK AND COUNTER TOP. IF WALL TO REMAIN PREP/PATCH

FOR REPAINTING.

9 DEMO GLASS WALL AND FRAMING. SALVAGE END CAPS FOR

REINSTALLATION.

10 DEMO COUNTER AND PLUMBING FIXTURE. PREP FOR NEW.

11 DEMO GLASS WALL AND DOOR

12 DEMO WINDOW

13 DEMO WALL, WALL BASE, DOOR/WINDOW/FRAME, AND ALL DEVICES

(DEMO CABELING BACK TO NEAREST J-BOX TO REMAIN). SALVAGE

DOOR/WINDOW/FRAME AS NEEDED FOR BUILD-BACK. LEAVE 12"

BULKHEAD

14 DEMO/SALVAGE FOR REUSE FLOOR MOUNTED FIXTURES AND TOILET

PARTITIONS. DEMO CERAMIC TILE (MAINTAIN COVE WALL BASE), PREP

FOR NEW FLOORING.

15 DEMO WALL, WALL BASE, DOOR/WINDOW/FRAME, AND ALL DEVICES

(DEMO CABELING BACK TO NEAREST J-BOX TO REMAIN). SALVAGE

DOOR/WINDOW/FRAME AS NEEDED FOR BUILD-BACK. TYP. WALL TO BE

REBUILT W/ CLERESTROY WINDOWS AND ADDITIONAL FRAMING

SUPPORT ABOVE CEILING

16 SALVAGE DOOR AND TURN OVER TO OWNER.

17 SALVAGE DOOR AND FRAME FOR REUSE, MARK DOOR NUMBER W/ TAPE

AND COORDINATE W/ OWNER/CONTRACTOR FOR STORAGE LOCATION

18 DEMO RECEPTION DESK TO THE WEST OF COLUMN, DEMO COUNTER

UNDER GLASS TRANSACTION WINDOW (REMOVE/SALVAGE

TRANSACTION WINDOW LEAVING TRANSUM GLASS IN PLACE)

19 DEMO BASE CABINET, counter, AND SINK

20 DEMO WALL FOR NEW OPENING OR DOOR

21 DEMO DOOR, FRAME, AND SIDELIGHT (IF APPLICABLE)

DEMOLITION GENERAL NOTES

1 DEMO ANY ITEMS ON WALLS LEFT BY PREVIOUS TENANTS (IE.

SIGNANGE, VINYL GRAPHICS...)

2 DEMO/SALVAGE ALL FLOOR MOUNTED POWER/DATA "TOMBSTONES"

(GIVE TO OWNER FOR STORAGE), REMOVE WIRE, CAP ALL OPENINGS IN

FLOOR.

3 DEMO ALL VINYL WALL BASE THROUGHOUT.

4 DEMO ALL ROOM, DOOR SIGNS

MARK DESCRIPTION DATE

2 ADM 24-APR-26

3 ADM 28-Apr-26

CGCG CGCG

CG

CG

CGCG

CG

CGCG

CGCG CGCG

CG

CGCG

CGCG

CG

CG

CG

CG CG CGCGCG

CGCG

CG

CG

CG CG

CG

CG

CGCG

CG

CGCG

CG

CG

CG CG

CG

CG

CG

CG

CG

CG

CG

CG

CG

CG

CG

CG

CG

CG

CG

CGCG

CG

CG

CG CGCG

CGCGCG

CG CG

CGCG CG

CG

CGCG

CG CG

CGCG

CG CG

CGCG

CG

CGCG

CG CG

CGCG

CG CG

CG CG

CG

CG

CG

CG

CG

CG

CG

CG

CG

CG

CG

CG

CG

CG

CG

CG

CG

CG

CG

CG CG

CG CG

CG CG

CG

CG CGCG

CG

CG CG

CG CG

CG CG

CG

CG CG

CG

CG

CG

CG

CG

CG

CG

CG

CG

CG

CGCG

CG

CGCG

CG

CG

CG

CG

CG

CG

CG

CG

CG CG

CG

CG CG

CG

CGCG

CG

CG

CG

CG

CG

CG

CG

CG

CG

CG

CGCG

CG

CG

CG

CG

CG

CG

CG

CG

CG

CG

CG

CG

CGCG

CG

CG

CG

CG

CG

CG

CG

CG

CG CG

CG

CG

CG

CG

CG

CGCG

CG

CG

SC

SD

SE

SF

SG

SH

SB

S3S2S1 S5 S6 S7 S9 S12S11S10 S13

SA

S15

PLAN

NORTH

ELEVELEV

CONFERENCE

BREAK ROOM

WORK ROOM

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

STORAGE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

STORAGE

OPEN OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

TRAINING

133132

1B

DISPLAY

LOBBY

STORAGE

5'-2"

10 10

5 5 555

555555555555

5 5 5 5 5 5

5 5 5 5

2 2

2 2

2 2

2 2 2 2

2 2 2 2

MEN

WOMEN

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

CONFERENCE ROOM

HALLWAY

HALLWAY

STORAGE

HALLWAY

OPEN OFFICE

WORK ROOM

HALLWAY

HALLWAY

HALLWAY

HALLWAY

CONFERENCE RM

HALLWAY

OFFICE

OFFICE

2 158

OFFICE

2 159

OFFICE

2 160

OFFICE

HALLWAY

CONFERENCE ROOM

HALLWAY

RECEPTION / LOBBY

WAITING

VEST

MEN

WOMEN

14 14

A

A

A

B

104 103

102 101 100

A

B

A

143A

143B

ROOF

NIC NIC

+/- 13'-11 1/2"

REM

/2 "3

/2

2'-8"

3'-5" 7'-2 1/2" VIF

ADM (CORNER GUARDS ADDED)

STUD PARTITION OR EXTERIOR CAVITY WALL -

REFER TO WALL TYPE SHEET FOR ADDITIONAL INFO

CMU WALL

EXISTING WALLS AND BUILDING ELEMENTS TO

REMAIN ARE DRAWN IN HALFTONE

CAST-IN-PLACE WALL

WALLS AND BUILDING ELEMENTS TO BE

DEMOLISHED ARE DRAWN WITH DASHED LINES

1t

PARTITION GRAPHICS / PHASING LEGEND

O P

N G

F L R

OPNG

4'-0" FLR

DEMOLISHED ELEMENTS SHOWN IN

PROJECTION ARE SURROUNDED BY DASHED

LINES AND FILLED WITH A DIAGONAL HATCH

Ph.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

B

A

C

D

E

F

G

H

J

K

L www.imegcorp.com

Des Moines, IA 50322

2822 106th Street

MEP Engineer

IMEG Corp.

515 334 9906

C op yr ig ht

S ub st an ce , L

LC

1300 Walnut Street, Suite 201 Des Moines, Iowa 50309 Ph. 515 243 4407 www.substancearchitecture.com

Revisions

Substance No.:

#9518

16 17 18

M

N

P

Date:

/2

/2

:0

:3

A M

A u to d e s k D o c s /0

-0

D

O M

-I T

J e s s ie

P a rk e r S o u th B u ild in g

R e n o v a ti o n

/D O

M -I

T J e s s ie

P a rk e r S o u th B ld g

R e n o

A R

C H

R

.r v t

D O

M -I

T D

O M

-I T

J e s s ie P a rk e r

S o u th

R e n o v a ti o n

D o c u m e n ts

A0.81

DEMOLITION PLAN - LEVEL 1

DOM-IT No.:

0719-01

April 10, 2026

SCALE: 1/8" = 1'-0"A1

LEVEL 1 DEMOLITION PLAN

DEMOLITION KEYNOTES

KEY NOTE

1 DEMO WALL BASE. (FLOORING TO BE DEMO'D W/ ABATEMENT NIC)

2 DEMO CARPET TILE AND WALL BASE. PREP FOR NEW FLOORING AND

BASE.

3 DEMO WALL AS NEEDED FOR NEW DOOR AND FRAME. VERIFY NO MEPT

CONFLICTS.

4 DEMO FLOORING AND WALL BASE. PREP FOR NEW FLOORING AND

BASE.

5 DEMO WINDOW COVERING

6 DEMO WALL, WALL BASE, DOOR/WINDOW/FRAME, AND ALL DEVICES

(DEMO CABELING BACK TO NEAREST J-BOX TO REMAIN). SALVAGE

DOOR/WINDOW/FRAME AS NEEDED FOR BUILD-BACK. TYP.

7 DEMO HANDRAIL (CUT FLUSH W/ FLOOR), GRIND TO BE BELOW FLOOR

SURFACE, PATCH FLOOR SLAB TO BE FLUSH AND SMOOTH WITH

SURROUNDING SURFACE.

8 DEMO CASEWORK AND COUNTER TOP. IF WALL TO REMAIN PREP/PATCH

FOR REPAINTING.

9 DEMO GLASS WALL AND FRAMING. SALVAGE END CAPS FOR

REINSTALLATION.

10 DEMO COUNTER AND PLUMBING FIXTURE. PREP FOR NEW.

11 DEMO GLASS WALL AND DOOR

12 DEMO WINDOW

13 DEMO WALL, WALL BASE, DOOR/WINDOW/FRAME, AND ALL DEVICES

(DEMO CABELING BACK TO NEAREST J-BOX TO REMAIN). SALVAGE

DOOR/WINDOW/FRAME AS NEEDED FOR BUILD-BACK.

14 DEMO/SALVAGE FOR REUSE FLOOR MOUNTED FIXTURES AND TOILET

PARTITIONS. DEMO CERAMIC TILE (MAINTAIN COVE WALL BASE), PREP

FOR NEW FLOORING.

15 DEMO WALL, WALL BASE, DOOR/WINDOW/FRAME, AND ALL DEVICES

(DEMO CABELING BACK TO NEAREST J-BOX TO REMAIN). SALVAGE

DOOR/WINDOW/FRAME AS NEEDED FOR BUILD-BACK. TYP. WALL TO BE

REBUILT W/ CLERESTROY WINDOWS AND ADDITIONAL FRAMING

SUPPORT ABOVE CEILING

16 SALVAGE DOOR AND TURN OVER TO OWNER.

17 SALVAGE DOOR AND FRAME FOR REUSE, MARK DOOR NUMBER W/ TAPE

AND COORDINATE W/ OWNER/CONTRACTOR FOR STORAGE LOCATION

18 DEMO RECEPTION DESK TO THE WEST OF COLUMN, DEMO COUNTER

UNDER GLASS TRANSACTION WINDOW (REMOVE/SALVAGE

TRANSACTION WINDOW LEAVING TRANSUM GLASS IN PLACE)

19 DEMO BASE CABINET, counter, AND SINK

20 DEMO WALL FOR NEW OPENING OR DOOR

21 DEMO DOOR, FRAME, AND SIDELIGHT (IF APPLICABLE)

DEMOLITION GENERAL NOTES

1 DEMO ANY ITEMS ON WALLS LEFT BY PREVIOUS TENANTS (IE.

SIGNANGE, VINYL GRAPHICS...)

2 DEMO/SALVAGE ALL FLOOR MOUNTED POWER/DATA "TOMBSTONES"

(GIVE TO OWNER FOR STORAGE), REMOVE WIRE, CAP ALL OPENINGS IN

FLOOR.

3 DEMO ALL VINYL WALL BASE THROUGHOUT.

4 DEMO ALL ROOM, DOOR SIGNS

MARK DESCRIPTION DATE

2 ADM 24-APR-26

3 ADM 28-Apr-263

ADM

APC-1

10' - 0"

GYPSUM BOARD

CEILING

CEILING MATERIALS

ACOUSTIC CEILING PANEL AND

GRID

CEILING

IDENTIFICATION

L1 P4N3

DENOTES ASSEMBLY TYPE

DENOTES HEIGHT (ABOVE FINISH

FLOOR UNLESS NOTED OTHERWISE)

LIGHTING FIXTURES

IF PROVIDED, ADJACENT TEXT INDICATES FIXTURE

TYPE, OTHERWISE REFER TO ELECTRICAL

DRAWINGS

HVAC FIXTURES

SUPPLY AIR RETURN AIR

COMMUNICATION AND DETECTION

FIXTURES

ACCESS

PANEL

SPRINKLER

HEAD

CAMERA

FIRE HORN /

STROBE

OCCUPAN

T SENSOR

SMOKE

DETECTOR

SPEAKER EXIT SIGN

M2

REFLECTED CEILING PLAN LEGEND

EXISTING

GYPSUM BOARD CEILING

EXISTING

ACOUSTIC CEILING PANEL AND

GRID

EXISTING BUILDING ELEMENTS TO REMAIN ARE DRAWN IN HALFTONE

BUILDING ELEMENTS TO BE DEMOLISHED ARE DRAWN WITH DASHED LINES

DEMOLISHED ELEMENTS SHOWN IN PROJECTION ARE SURROUNDED…