RFB918604-01 - Drawings.pdf
PDF 12 MB Posted
- Attached to
- Hoover 3rd Floor Renovations
- Solicitation number
- RFB918604-01
- Issued by
- Polk County, Iowa
About this file
The provided document is a set of drawings (RFB918604-01 - Drawings.pdf) related to the Hoover 3rd Floor Renovations contract opportunity issued by the Department of Public Defense in the state of Iowa. This contract opportunity seeks proposals from qualified Respondents to modernize the Supervisory Control and Data Acquisition (SCADA) system. The document does not provide details on the project timeline, response due dates, site visits, or contract term.
The pricing terms, set asides, incumbent information, funding requirements, and other salient details are not included in the provided document. This document appears to be focused on providing the technical drawings related to the renovation project rather than the full solicitation details.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFB918604-01 - Bid Form.pdf | ||
| RFB918604-01 - Hoover 3rd Floor Schedule (FINAL).pdf | ||
| Project Manual RFB918604-01.html | HTML file | |
| Pre-Bid Meeting - Google Meet.html | HTML file | |
| Bid Opening - Google Meet.html | HTML file | |
| RFB918604-01 - Notice.pdf | ||
| RFB918604-01 - Project Manual.pdf | ||
| Bid Documents and Drawings.html | HTML file | |
| 1258264-event.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
XX
09 2116; MTL
FRAMING
09 2116; GYP BD
09 2116; GYP BD
07 2100;
ACOUSTIC BATT
INSUL
ASSEMBLY WIDTH
*BRACE ALL INTERIOR
PARITIONS @ HEAD CONDITION
ABOVE CEILING AS NECESSARY
L- LightGage Metal Stud Assemblies
M- CMU
S- Structural Metal Stud Assemblies W- Wood Stud Assemblies X- Exterior Wall
CORE MATERIAL
X#.#
WALL TYPE
DESIGNATION
NOMINAL CORE SIZE
Wall Type Naming Key
1. SEAL ALL PENETRATIONS THROUGH NON-FIRE RATED INTERIOR PARTITIONS
AND FLOOR SLABS NOT ON GRADE WITH ACOUSTIC SEALANT. ALL INTERIOR
WALLS ARE WALL TYPE "L4.3" UNLESS NOTED OTHERWISE
GENERAL NOTES
GENERAL FILL
BATT INSULATION
CONCRETE
GYPSUM BOARD
WOOD BLOCKING
RIGID INSULATION
STEEL
PLYWOOD
MINERAL FIBER
BOARD INSULATION
BRICK
CONCRETE
MASONRY UNIT
WOOD SHIM
GRANULAR
DRAINAGE FILL
FOAM-IN-PLACE
INSULATION
MATERIAL SYMBOLS
DETAIL SECTION
ELEVATION
WALL SECTION
BUILDING SECTION
WALL TYPE
DOOR NUMBER
WINDOW TAG
REVISION TAG
ELEVATIONS
ROOM IDENTIFICATION
DETAIL IDENTIFICATION
SHEET WHERE SHOWN
SHEET WHERE SHOWN
ELEVATION IDENTIFICATION
SECTION IDENTIFICATION
SHEET WHERE SHOWN
SECTION IDENTIFICATION
SHEET WHERE SHOWN
ROOM NAME
ROOM NUMBER
A-401
1 Ref
R e f
1 Ref
R e f
CASEWORK ELEVATION TAG
AWS SERIES
HEIGHT
WIDTH
DEPTH
NOTE:
HEIGHT IS TO TOP OF
COUNTER
NOTE:
DEPTH IS TO FACE OF
FINISHED WALL TO FACE
OF CABINET DOOR
G2
Issued by
1132 A
Room name
A-101
A1
SIM
A1
A-101
SIM
Name Elevation
A1
A-101
SIM
A1
A-101
SIM
ROOF TAG
FLOOR TAG
F1
R1
REFERENCE INDICATIONS
MODIFIED
DESCRIPTION
MODIFIED DESIGNATOR
LOCKED
SPECIALITY WALL FINISH
KEY NAME OF
INTERIOR MATERIAL
LINE OF INTERIOR
MATERIAL EXTENTS
212M24" 36"
24"
Modified Description
SHEET NUMBER
SHEET NAME
PROJECT NO.
OWNER
PROJECT NAME
CONSULTANTS
© NEUMANN MONSON INC.
Unauthorized copying, disclosure or construction without written permission by Neumann Monson Inc. is prohibited.
ARCHITECT OF RECORD
Neumann Monson Architects
221 East College Street | Suite 303
Iowa City, Iowa 52240
319.338.7878
111 East Grand Avenue | Suite 105
Des Moines, Iowa 50309
515.339.7800
ISSUE
DATE DESCRIPTION
KCL Engineering
MEP
300 4th St.
West Des Moines, IA 50265
515.724.7938
T B
V e rs io n
.3
VICINITY MAP
INDEX OF DRAWINGS
KEY PLAN
ALL ARCH SHEETS TO BE PRINTED IN COLOR
G-001
TITLE SHEET AND
DRAWING INDEX
24.048
STATE OF IOWA
RFB No. 918604-01
9186.04 - DHS CC
STRATEGIC
SPACE PLANNING
HOOVER 3RD
FLOOR DEPT OF
ADMIN SERVICES
DAS No. 9186.04
50% CONSTRUCTION DOCUMENTS07/17/2024
95% CONSTRUCTION DOCUMENTS08/09/2024
9186.04 - DHS CC STRATEGIC SPACE PLANNING
HOOVER 3RD FLOOR DEPT OF ADMIN SERVICES
1305 E Walnut Street Thrid Floor, Des Moines, IA 50319
100% CONSTRUCTION DOCUMENTS08/22/2024
GENERAL INFORMATION DRAWINGS
G-001 TITLE SHEET AND DRAWING INDEX
G-002 CODE INFORMATION
ARCHITECTURAL DRAWINGS
A-103 THIRD LEVEL FLOOR PLANS
A-113 THIRD LEVEL REFLECTED CEILING PLANS
A-411 INTERIOR ELEVATIONS
A-601 DOOR SCHEDULES, ROOM FINISH SCHEDULES
INTERIOR DRAWINGS
AF-103 THRID LEVEL FLOOR FINISH PLAN
FIRE PROTECTION DRAWINGS
FA-001 FIRE ALARM COVER
FA-103 THIRD LEVEL FIRE DETECTION & ALARM PLAN
F-103 THIRD LEVEL FIRE PROTECTION PLAN
MECHANICAL DRAWINGS
M-000 MECHANICAL GENERAL NOTES & SYMBOLS
MD-103 THIRD LEVEL MECHANICAL DEMOLITION
M-103 THIRD LEVEL MECHANICAL HVAC PLAN
M-301 MECHANICAL DETAILS
ELECTRICAL DRAWINGS
E-000 ELECTRICAL GENERAL NOTES & SYMBOLS
ED-103 THIRD LEVEL ELECTRICAL DEMOLITION
E-103 THIRD LEVEL ELECTRICAL POWER
E-203 THIRD LEVEL ELECTRICAL LIGHTING
E-301
TELECOMMUNICATION DRAWINGS
T-000 TECHNOLOGY COVER
TD-103 THIRD LEVEL TECHNOLOGY DEMOLITION PLAN
T-103 THIRD LEVEL TECHNOLOGY COMMUNICATIONS PLAN
T-203 THIRD LEVEL TECHNOLOGY SOUND MASKING PLAN
T-300 TECHNOLOGY DETAILS
@ AT
AC ACOUSTICAL COMPONENT
ACST ACOUSTICAL
ADJ ADJACENT OR ADJUSTABLE
AFF ABOVE FINISH FLOOR
AL ALUMINUM
ALT ALTERNATE
ANOD ANODIZED
APCC ARCHITECTURAL PRECAST CONCRETE
APPROX APPROXIMATE
ARCH ARCHITECTURAL
ATC ACOUSTICAL TILE CEILING
AV AUDIO VISUAL
AW ARCHITECTURAL WOODWORK
BD BOARD
BEJ BRICK EXPANSION JOINT
BLDG BUILDING
BLKG BLOCKING
BO_ BOTTOM OF ____
BRG BEARING
CG CORNER GUARD
CIPC CAST-IN-PLACE CONCRETE
CJ CONTROL JOINT
CL CENTER LINE
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
CPT CARPETING / CARPET TILE
CW CURTAIN WALL
DBL DOUBLE
DEMO DEMOLITION / DEMOLISH
DF DRINKING FOUNTAIN
DIA DIAMETER
DN DOWN
DR DOOR
DS DOWNSPOUT
DTL DETAIL
DW DISHWASHER
DWG DRAWING(S)
EA EACH
EIFS EXTERIOR INSULATION AND FINISH SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
EQ EQUAL
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
EX EXPOSED
EXH EXHAUST
EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR
FACP FIRE ALARM CONTROL PANEL
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FE FIRE EXTINGUISHER ON BRACKET
FEC FIRE EXTINGUISHER CABINET
FF FINISHED FACE OR FLOOR
FIN FINISH
FLEX FLEXIBLE
FLR FLOOR
FTG FOOTING
FURN FURNITURE/FURNISHINGS
G GROUT
GA GAGE
GALV GALVANIZED
GFR GLASS-FIBER-REINFORCED
GYP GYPSUM
GYP BD GYPSUM BOARD
HM HOLLOW METAL
HORIZ HORIZONTAL
HT HEIGHT
IB INTEGRAL BASE
INSUL INSULATION
INT INTERIOR
JT JOINT
LKR LOCKER
MAS MASONRY
MAT ENTRY WALK-OFF MAT
MAX MAXIMUM
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM
MIRR MIRROR OR MIRRORED
MTL METAL
MTLP METAL PANEL
L4.X METAL STUD ASSEMBLIES W/ 1 LAYER
GYP BD EACH SIDE AND ACOUSTIC INSULATION
Mark Stud Size
Assembly Width
UL Design Rating Comments
L4.3 3 5/8" 4 7/8" PNT-1
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER OR DIMENSION
OF/CI OWNER FURNISHED, CONTRACTOR INSTALLED
OF/OI OWNER FURNISHED, OWNER INSTALLED
OPNG OPENING
OPP OPPOSITE
ORD OVERFLOW ROOF DRAIN
PCC PRECAST CONCRETE
PCONC POLISHED CONCRETE
PEF POURED EPOXY FLOORING
PL PLATE
PLAM PLASTIC LAMINATE
PLBG PLUMBING
PLYWD PLYWOOD
PNT PAINT(ED)
PR PAIR
R RISER
RB RESILIENT BASE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REBAR REINFORCING BAR(S)
REF REFERENCE
REFR REFRIGERATOR
REINF REINFORCE OR REINFORCING
REQD REQUIRE(D)
RF RESILIENT FLOORING
RM ROOM
RO ROUGH OPENING
RR RESTROOM
RST REINFORCING STEEL
RWP RIGID SHEET WALL PROTECTION
SATC SUSPENDED ACOUSTICAL TILE CEILING
SCHED SCHEDULE
SCONC SEALED CONCRETE
SECT SECTION
SF SQUARE FOOT OR FEET
SHT SHEET
SHTHG SHEATHING
SIM SIMILAR
SIPS STRUCTURAL INSULATED PANELS
SLNT SEALANT
SLNT/BR SEALANT AND BACKER ROD
SOG SLAB-ON-GRADE
SSM SOLID SURFACING MATERIAL
SST STAINLESS STEEL
STD STANDARD
STF STOREFRONT
STL STEEL
STRUCT STRUCTURAL
SUSP SUSPENDED
T TREAD OR TILE
T&B TOP AND BOTTOM
TAC TACKBOARD
TELECOM TELECOMMUNICATION(S)
TOB TOP OF BEAM
TOC TOP OF CONCRETE/COUNTER
TOF TOP OF FRAME
TOJ TOP OF JOIST
TOM TOP OF MASONRY
TOS TOP OF SLAB OR STEEL
TOW TOP OF WALL
TYP TYPICAL
TZ TERRAZZO
UON UNLESS OTHERWISE NOTED
VAR VARIES
VERT VERTICAL
VIF VERIFY IN FIELD
W/ WITH
W/O WITHOUT
WB WALL BUMPER
WC WALL COVERING
WD WOOD
WDP WOOD PANEL
WWF WELDED WIRE FABRIC
PROJECT SITE
I hereby certify that the portion of this technical submission described below was prepared by me or under my direct supervision and responsible charge.
I am a duly licensed Architect under the laws of the State of Iowa.
Signature Date
License renewal date:
Pages or sheets covered by this seal:
License #:
June 30, 2026
G SHEETS & A SHEETS
Lyndley E. Kent
07563
08/22/2024Signature Date
License renewal date:
Pages or sheets covered by this seal:
I hereby certify that this engineering document was prepared by me or under my direct supervision and that I am a duly licensed Professional Engineer under the laws of the State of Iowa.
08/22/2024
December 31, 2025
F SHEETS & M SHEETS
CHAD D. BASS
LIST OF ABBREVIATIONS
1. REFER TO SPECIFICATION SECTION 09 2116 - GYPSUM BOARD ASSEMBLIES FOR MINIMUM STUD THICKNESS, MAXIMUM STUD SPACING, AND PERFORMANCE CRITERIA FOR NON-LOAD- BEARING METAL-FRAMED GYPSUM BOARD WALL AND SHAFT WALL ASSEMBLIES; INCLUDING MAXIMUM DEFLECTION, ACOUSTICAL-RATED, FIRE-RESISTANCE-RATED, AND SMOKE- RESISTANCE-RATED REQUIREMENTS. CONSTRUCT ACOUSTICAL-RATED, FIRE-RESISTANCE-RATED, AND SMOKE-RESISTANCE-RATED WALLS ACCORDING TO THEIR RESPECTIVE ASSEMBLY TEST REPORTS. ENSURE MATERIALS USED WITHIN AN ASSEMBLY COMPLIES WITH MANUFACTURER’S DATA AND THE PRODUCT QUALITIES INDICATED IN THEIR RESPECTIVE
ASSEMBLY SPECIFICATIONS AND TEST REPORTS.
2. PENETRATIONS THROUGH, AND THE PERIMETER OF FIRE-RESISTANCE-RATED WALLS, SHALL BE FILLED WITH AN APPROPRIATE FIRESTOPPING SYSTEM MEETING PERFORMANCE REQUIREMENTS INDICATED ON DRAWINGS AND AS SPECIFIED IN SECTION 07 8400 - FIRESTOPPING.
3. EXTEND WALL FRAMING TO BOTTOM OF EXISTING CEILING IN ALL LOCATIONS, UNLESS SPECIFICALLY NOTED OTHERWISE, ALLOWING FOR DEFLECTION WHILE MAINTAINING APPROPRIATE
ACOUSTICAL-RATING.
4. ACOUSTICAL-RATED WALLS SHALL HAVE ACOUSTIC SOUND BATT INSULATION WITHIN STUD SPACE FOR THE ENTIRE LENGTH AND HEIGHT OF WALL AND ACOUSTIC SEALANT AT ENTIRE PERIMETER OF GYPSUM BOARD, INCLUDING PENETRATIONS, EXCEPT WHERE FIRESTOPPING IS PROVIDED.
5. UL LISTINGS ON THIS DRAWING SHEET ONLY APPLY TO WALLS THAT ARE REQUIRED TO BE FIRE-RESISTANCE-RATED AND SMOKE-RESISTANCE-RATED. REFER TO CODE SHEET G-002 FOR IDENTIFICATION AND EXTENT OF WALLS REQUIRED TO BE FIRE-RESISTANCE-RATED AND SMOKE-RESISTANCE-RATED.
6. WALLS REQUIRED TO BE FIRE-RESISTANCE-RATED AND SMOKE-RESISTANCE-RATED SHALL BE IDENTIFIED WITH A LABEL ABOVE THE CEILING ON EACH SEGMENT OF WALL, LOCATED NO MORE THAN 20’-0” ON CENTER ON BOTH SIDES OF WALL OR AS OTHERWISE REQUIRED BY AHJ.
7. FIRE-RESISTANCE-RATED AND SMOKE-RESISTANCE-RATED WALLS SHALL EXTEND AND SEAL TO INTERIOR FACE OF EXTERIOR SHEATHING, INCLUDING EXTENSIONS THROUGH SOFFITS.
8. CUT GYPSUM TO CONTOURS OF ROOF DECK FLUTES AND SEAL WITH ACOUSTIC SEALANT ON EACH SIDE.
GENERAL WALL TYPES NOTES
Signature Date
License renewal date:
Pages or sheets covered by this seal:
I hereby certify that this engineering document was prepared by me or under my direct supervision and that I am a duly licensed Professional Engineer under the laws of the State of Iowa.
08/22/2024
December 31, 2025
E SHEETS & T SHEETS
ERIC HEYNEN
CODE PLAN LEGEND
SYMBOL DESCRIPTION NOTES
FIRE EXTINGUISHER
FIRE EXTINGUISHER
CABINET
COMPLY WITH
IFC906
1 HR RATED SEPARATION
2 HR RATED SEPARATION
3 HR RATED SEPARATION
1 HOUR FIRE RESISTANCE RATED
CONSTRUCTION.
3/4 HOUR RATED DOOR ASSEMBLIES (UNO)
FIRE & SMOKE DAMPERS.
2 HOUR FIRE RESISTANCE RATED
CONSTRUCTION.
1 1/2 HOUR RATED DOOR ASSEMBLIES (UNO)
FIRE & SMOKE DAMPERS.
3 HOUR FIRE RESISTANCE RATED
CONSTRUCTION.
2 HOUR RATED DOOR ASSEMBLIES
(UNO)
FIRE & SMOKE DAMPERS.
OCCUPANCY AREA TAG
MEANS OF EGRESS
DOOR TAG
NUMBER OF CALCULATED
OCCUPANTS
OCCUPANT LOAD
FACTOR (SQ. FT. /
PERSON)
TOTAL NUMBER OF
OCCUPANTS EXITING
CAPACITY OF EXIT
ELEMENT
ACTUAL EXIT WIDTH
(INCHES)
SQ. FT. OF AREA
NUMBER OF ADVANCING
OCCUPANTS
DIRECTION OF TRAVEL
TRAVEL DISTANCE
TRAVEL PATH
XXX
XXX
XX.X
STAIR
XXX
XXX
XX.X
TOTAL NUMBER OF
OCCUPANTS EXITING
CAPACITY OF EGRESS
STAIR
ACTUAL STAIR WIDTH
(INCHES)
MEANS OF EGRESS
STAIR TAG
XXX SF XXX
XX
FEC
FE
FECFEC
Path Length
156 SF
185 SF
177 SF
325 SF
150 205 SF
150 181 SF
288 SF
270 SF
167 SF
971 SF
3,589 SF
5,269 SF
27 SF
300 54 SF
25 SF
300 39 SF
300 31 SF
154'
FE
2,381 SF
32.88
32.88
32.88
44.88
38.88
FEC
NEW FIRE
EXTINGUISHER &
BRACKET
USE AND OCCUPANCY CLASSIFICATION LEGEND
A-3: ASSEMBLY
B: BUSINESS
S-1: STORAGE
SHEET NUMBER
SHEET NAME
PROJECT NO.
OWNER
PROJECT NAME
CONSULTANTS
© NEUMANN MONSON INC.
Unauthorized copying, disclosure or construction without written permission by Neumann Monson Inc. is prohibited.
ARCHITECT OF RECORD
Neumann Monson Architects
221 East College Street | Suite 303
Iowa City, Iowa 52240
319.338.7878
111 East Grand Avenue | Suite 105
Des Moines, Iowa 50309
515.339.7800
ISSUE
DATE DESCRIPTION
KCL Engineering
MEP
300 4th St.
West Des Moines, IA 50265
515.724.7938
T B
V e rs io n
.3
KEY PLAN
ALL ARCH SHEETS TO BE PRINTED IN COLOR
G-002
CODE
INFORMATION
24.048
STATE OF IOWA
RFB No. 918604-01
9186.04 - DHS CC
STRATEGIC
SPACE PLANNING
HOOVER 3RD
FLOOR DEPT OF
ADMIN SERVICES
DAS No. 9186.04
50% CONSTRUCTION DOCUMENTS07/17/2024
95% CONSTRUCTION DOCUMENTS08/09/2024
100% CONSTRUCTION DOCUMENTS08/22/2024
2015 International Building Code (New Building Code Analysis)
IBC Chapter 1 – Administration
105.1 Before construction an application shall be submitted to the building official to obtain the required permit.
107.3.1 An approved set of plans including plan review comments is to be kept on the job site and be available to the building inspectors.
IBC Chapter 2 – Definitions *Include applicable definitions if needed*
IBC Chapter 3 – Use and Occupancy B (Business Group) Level 3 A-3 (Assembly Group) Level 3
IBC Chapter 5 – Building Heights and Areas Allowable Heights and Areas (Construction Type IB, Sprinklered):
Heights/ Stories - 160ft/ 12 Stories Area - UL
Actual Heights and Areas Heights/ Stories - 58 ft / 4 Stories (renovation - 1 story) Area - 14,173 sf
IBC Chapter 6 – Type of Construction Type: I-B
Tbl 601 Fire-resistance Rating for Building Elements Structural frame 2 hr Bearing walls 2 hr Non-bearing walls 0 hr Floor Construction 2 hr Roof Construction 1 hr
IBC Chapter 7 – Fire and Smoke Protection
Tbl 705.5 Fire-resistance Rating for Exterior Walls 5ft ≤ X < 10ft 1 hr
Tbl 705.8 Maximum Area of Openings 5ft ≤ X < 10ft 25% 10ft ≤ X < 15ft 45%
713.4 Shaft enclosures shall have a fire-resistance rating of not less than 2 hours where connecting four or more stories, and not less than 1 hour where connecting less than four stories.
IBC Chapter 9 – Fire Protection Systems
903.2.8 An automatic sprinkler system in accordance with NFPA is provided.
906.1 Portable fire extinguishers shall be installed in occupancy groups B & R-2. Each dwelling unit shall be provided with a portable fire extinguisher with minimum rating of 1-A:10-B:C.
Tbl 906.3 Except in Group R-2, a 2-A rated extinguisher shall be located within a maximum travel distance of 75 feet.
IBC Chapter 10 – Means of Egress
Tbl 1004.5 Maximum Floor Area Per Occupant Business Areas 150 gross = 94 Occupants Assembly (A-3) 15 net = 64 Occupants Storage (S-1) 300 gross = 5 Occupants
Tbl 1017.2 Exit Access Travel Distance Group B (Sprinklered) 300ft Group A (Sprinklered) 250ft
IBC Chapter 11 – Accessibility
1110.15 Controls, operating mechanisms and hardware intended for operation, switches, and electrical outlets, in accessible spaces, shall be accessible.
IBC Chapter 29 – Plumbing
Tbl 2902.1 Minimum Number of Plumbing Fixtures, (or Tbl 422.1 of the Iowa State Plumbing Code) Required
Group B 1 WC per 25 1 Lav per 40 1 WC per 50 after 50 1 Lav per 80 exceeding 80
Group A 1 WC per 125 (M) 1 WC per 65 (F) 1 per 200 Total Group B: 2 (M)
Group B: 2 (F) Group A: 1 (M) Group A: 1 (F) 3 WC's Lav: Group B - 2 + Group A - 1 = 3 total Lavs
Drinking Fountains Group B 1 per 100 Group A 1 per 500 Total Group B: 1
Group A: 1
Provided Men 5 WCs, 3 Urinals 7 Lav Women 8 WCs 7 Lav Drinking Fountains 2 Total 16 WCs. (or Urinals) 14 Lavs 2 Drinking Fountains
*Per International Plumbing Code section 419.2 Substitution for water closets. In each bathroom or toilet room, urinals shall not be substituted for more than 67 percent of the required water closets in assembly and educational occupancies. Urinals shall not be substituted for more than 50 percent of the required water closets in all other occupancies.
IBC Chapter 30 – Elevators
3001.2 An emergency two-way communication system with visible text and audible modes shall be provided that:
1. When operating in each mode, include a live interactive system that allows back and forth conversation between the elevator occupants and emergency personnel.
2. Is operational when the elevator is operational.
3. Allows elevator occupants to select the text-based or audible modes.
1/16" = 1'-0"
LEVEL 3 USE & OCCUPANCY PLAN
Code Review (IEBC Analysis)
Project:9186.04 - DHS CC Strategic Space Planning Hoover 3rd Floor Dept of Admin Services
Address: 1305 E Walnut St Des Moines, IA 50319
Date: 2024.08.19
Applicable Codes 2015 International Building Code 2021 State Mechanical (Based on 2021 International Mechanical Code) 2015 International Fire Code 2020 National Electrical Code 2021 State Plumbing Code (Based on 2021 Uniform Plumbing Code) 2012 International Energy Conservation Code
Project Description Level 3 renovation of Hoover Building - DAS offices.
Primary: Group B, offices include professional or service-type transactions, including storage of records and accounts.
BASIC INFORMATION
Renovation 14,173 GSF (North portion of level 3 floor plate) Construction Type: I-B Occupancy Groups B (Level 3), A-3 (Level 3)
Chapter 1 - Scope and Administration Demolition work to follow IEBC Chapter 15 All sub-contractors will need to apply for and obtain their own specialty permits.
An approved set of plans including plan review comments is to be kept on the job site and be available to the building inspectors.
Chapter 2 - Definitions See IBC 2021
Proposed Building Type 1-A
Alterations – Level 2
14,159 GSF
3 stories above grade Building height: 58'-0" above grade plane average parapet height.
Fully sprinklered per Section 903 of the 2021 International Fire Code.
Chapter 4 – Repairs Construction Type: I-A
403 Fire Protection Repairs shall be done in a manner that maintains the level of fire protection provided.
(Table 601 IBC) REQ. PROVIDED Structural Frame including columns, girders & trusses 3 hr 3 hr Bearing Walls--Exterior 3 hr 3 hr Bearing Walls--Interior 3 hr 3 hr Nonbearing walls & partitions--Exterior 1 hr 1 hr* Nonbearing walls & partitions--Interior 0 hr Varies Floor Construction including supporting beams & joists 2 hr 2 hr Roof Construction including supporting beams & joists 1 hr 1 hr**
* New additions will be rated to 1 hr. Existing exterior walls will meet or exceed a 2hr rating.
Chapter 6 – Classification of Work
602.1 Scope
Level 1 alterations include the removal and replacement or the covering of existing materials, elements, equipment, or fixtures using new materials, elements, equipment, or fixtures that serve the same purpose.
602.2 Application
Level 1 alterations shall comply with the provisions of chapter 7.
603.1 Scope
Level 2 alterations include the reconfiguration of space, the addition or elimination of any door or window, the reconfiguration or extension of any system, or the installation of any additional equipment.
603.2 Application
Level 2 alterations shall comply with the provisions of Chapter 7 for Level 1 alterations as well as the provisions of Chapter 8.
606.1 General
Structural repairs shall be in compliance with section 606 and Section 601.2 and the detailing provisions of the International Building Code for new buildings of similar structure, purpose and location
707 Alterations - Level 1
702.1 Interior Finishes
Newly installed interior wall and ceiling finishes shall comply with Chapter 8 of the International Building Code.
702.2 Interior Floor Finish
New interior floor finish, including new carpeting used as an interior floor finish material, shall comply with Section 804 of the International Building Code.
702.3 Interior Trim
Newly installed interior trim materials shall comply with Section 806 of the International Building Code.
702.6 Materials and Methods
New work shall comply with the materials and methods requirements in the International Building Code, International Energy Conservation Code, International Mechanical Code, and International Plumbing Code, as applicable, that specify material standards, detail of installation and connection, joints, penetrations, and continuity of any element, component, or system in the building.
704.1 Means of Egress
Alterations shall be done in a manner that maintains the level of protection provided for the means of egress.
Chapter 8 – Alterations Level 2
801.2 Alteration Level 1 compliance
In addition to the requirements of this chapter, all work shall comply with the requirements of Chapter 7.
801.3 Compliance
New construction elements, components, systems and spaces shall comply with the requirements of the International Building Code.
Exceptions:
Windows may be added without requiring compliance with the light and ventilation requirements of the International Building Code.
803 Fire Protection The requirements of this section shall be limited to work areas in which Level 2 alterations are being per-formed, and where specified they shall apply throughout the floor on which the work areas are located or otherwise beyond the work area.
803.2 Automatic sprinkler systems
Automatic sprinkler systems shall be provided in accordance with the requirements of Sections 803.2.1 through
803.2.4. Installation requirements shall be in accordance with the International Building Code.
803.2.2 Groups A, B, E, F-1, H, I, M, R-1, R-2, R-4, S-1 and S-2.
In buildings with occupancies in Groups A, B, E, F-1, H, I, M, R-1, R-2, R-4, S-1 and S-2, work areas that have exits or corridors shared by more than one tenant or that have exits or corridors serving an occupant load greater than 30 shall be provided with automatic sprinkler protection where both of the following conditions occur:
805.8 Exit Signs
Exit signs shall be in accordance with this section, as applicable.
805.8.1 Work Areas
Means of egress in all work areas shall be provided with exit signs in accordance with the requirements of the
International Building Code.
2021 LIFE SAFETY - OCCUPANT LOADS
Number Name 2021 Space Function Per IBC Chapter 10 Area 2021 Occupancy Load Factor 2021 Occupant Load
H374 CONFERENCE
ROOM
Assembly W/out Fixed Seats-Unconcentrated (tables and chairs)
185 SF 15 13
H366 CONFERENCE
ROOM
Assembly W/out Fixed Seats-Unconcentrated (tables and chairs)
288 SF 15 20
H364 CONFERENCE
ROOM
Assembly W/out Fixed Seats-Unconcentrated (tables and chairs)
270 SF 15 19
H362 CONFERENCE
ROOM
Assembly W/out Fixed Seats-Unconcentrated (tables and chairs)
167 SF 15 12
H372 OFFICE Business Areas 156 SF 150 2
H368 OFFICE Business Areas 177 SF 150 2
H342 OPEN OFFICE Business Areas 325 SF 150 3
H344 OFFICE Business Areas 205 SF 150 2
H346 OFFICE Business Areas 181 SF 150 2
H352 OPEN OFFICE Business Areas 971 SF 150 7
H370 OFFICE Business Areas 3,589 SF 150 24
H354 OPEN OFFICE Business Areas 5,269 SF 150 36
H340 OPEN OFFICE Business Areas 2,381 SF 150 16
H348 ELEC Mercantile- Storage, Stock, Shipping Areas 27 SF 300 1
H350 COMM Mercantile- Storage, Stock, Shipping Areas 54 SF 300 1
H361 ELEC Mercantile- Storage, Stock, Shipping Areas 25 SF 300 1
H363 COMM Mercantile- Storage, Stock, Shipping Areas 39 SF 300 1
H366 STOR Mercantile- Storage, Stock, Shipping Areas 31 SF 300 1
14,339 SF 163
1. ALL DIMENSIONS ARE TO FINISH FACE, UNLESS OTHERWISE NOTED.
2. WALLS TO BE TYPE L4.3, UNLESS OTHERWISE NOTED.
3. REPAIR AND PATCH CONCRETE FLOOR WHERE DAMAGED OR UNFINISHED
RESULTING FROM DEMOLITION WORK.
4. WHEREVER DEMOLITION OF WALLS, CEILINGS, FLOORS, CASEWORK, OR OTHER
ITEMS RESULTS IN EXPOSED, UNFINISHED EDGES, PLANES, OR FACES OF ADJOINING
WALLS, CEILINGS, FLOORS, ETC., THESE UNFINISHED ELEMENTS SHALL BE REPAIRED,
PATCHED AND FINISHED WITH LIKE/COMPATIBLE MATERIALS AS REQUIRED TO MATCH
ADJACENT SURFACE, UNLESS OTHERWISE NOTED IN THE DOCUMENTS.
5. WHERE REMOVAL OF ITEMS REQUIRED BY THIS CONTRACT, INCLUDING PLUMBING,
MECHANICAL, ELECTRICAL, AND TELECOM ITEMS, LEAVES HOLES IN THE EXISTING
WALLS, FLOORING, FLOOR SLAB, CEILINGS, AND/OR ROOF DECK, CONTRACTOR
SHALL PATCH ALL HOLES LEFT FROM REMOVAL OF THESE ITEMS TO MATCH
ADJACENT ASSEMBLY AND SURFACE PRIOR TO REFINISHING.
6. REFER TO THE UNDERSLAB MEP PIPING PLANS FOR ADDITIONAL AREAS OF PATCHING
CONCRETE FLOORS FOR UNDERSLAB PIPING NOT SHOWN ON THE ARCHITECTURAL
PLANS.
7. ALL WALL MOUNTED FIRE EXTINGUISHERS AND BRACKETS TO BE PROTECTED /
REINSTALLED AFTER PAINTING OF WALL SURFACE.
GENERAL FLOOR PLAN NOTES
5 6 7 8 10 11
35'-0" 35'-0" 35'-0" 35'-0" 35'-0" 35'-0" 35'-0"
B
C
A
12943
2'-0"
14'-10"
/4
24'-6"
15'-0"
OFFICE
H342
OFFICE
H344
OFFICE
H346
OFFICE
H368
OFFICE
H372
CONFERENCE
ROOM
H374
CONFERENCE
ROOM
H366
CONFERENCE
ROOM
H364
CONFERENCE
ROOM
H362
OPEN OFFICE
H352
H 342 H
H
H374
H366
H364
H362
OPEN OFFICE
H340
OPEN OFFICE
H354
OPEN OFFICE
H360
OPEN OFFICE
H370
H 360-A
ELEC
H361
COMM
H363
STOR
H365
H
H
H
H
H368 H372
ELEC
H348
COMM
H350
H
H
2'-0"
H
H
359-AH
H -A
H340
CORRIDOR
H359
CORRIDOR
H353
WALL TO BE FILLED,
PATCHED, & FINISHED
TO MATCH ADJACENT
A L
IG
N
A-411
A4
B4
/2
ALIGN
ALIGN
EXISTING PUSH BUTTON FOR
DOOR H360A TO REMAIN
(EXACT LOCATION: VIF)
H
4'-0"
12 3600; SSM
COUNTERTOP
A L
IG
N
A-411
C4
A-411 C5
A-411
D5
A-411
D4
A-411 E5
H352-A
A-411
A2
EXISTING WINDOW
TO REMAIN
V
IF
EXISTING DOOR H360
TO BE MODIFIED WITH
HALF GLASS CUT OUT
NEW CLERESTORY GLAZING
SEE ELEVATION A4 / A-411
A L
IG
N
EXISTING WINDOW TO
BE FILLED - FINISH TO
MATCH ADJACENT
CR
EXISTING
CR
EXISTING
CR
EXISTING
A-411
A2
EXISTING PUSH BUTTON FOR
DOOR H360 TO REMAIN
(EXACT LOCATION: VIF)
A L
IG
N
E Q
E Q
A-411
E4 6'-2"
OWNER
PROVIDED
REFRIGERATOR
OWNER
PROVIDED
REFRIGERATOR
PATCH & REPAIR
WALL AS NECESSARY
FOR PAINTING
PATCH WALL WITH
METAL STUDS AND
DRYWALL WHERE
FEC WAS REMOVED
OWNER
PROVIDED
REFRIGERATOR
CENTER WALL ON MULLION CENTER WALL ON MULLION
SALVAGE EXISTING MAILSLOT IN
THE CORRIDOR H359 AND INSTALL
@ THIS LOCATION 42" AFF
5 6 7 8 10 11
B
C
2'-0" 35'-0" 35'-0" 35'-0" 35'-0" 35'-0" 35'-0" 35'-0" 2'-0"
A
12943
9'-10 1/2"
9'-11"
OFFICE
H342
OFFICE
H344
OPEN OFFICE
H352
OPEN OFFICE
H340
OPEN OFFICE
H370
CONF
H368
CONF
H356
CONF
H358
CONF
H346
H 342 H
H
H 360-A
H
H
3 H
ELEC
H361
COMM
H363
STOR
H365
ELEC
H348
COMM
H350
H
H
H340
H
359-AH
UP
EXISTNG WINDOW SHADES TO REMAIN
COVER & PROTECT THROUGH CONSTRUCTION
LINE OF EXISTING
SOFFIT OVERHEAD
D1
D2D3
D1
D1
D3
D1
D4D5
D6
D7
D7
D8
D9D9 D9
D9
OPEN OFFICE
H360
D10
D10 D10
D10
D10
D10
D10
D10
D10
D10
D10
D10
D10
D10 D10
D10
D10
D10
D11
D12
LINE OF EXISTING
SOFFIT OVERHEAD
REMOVE & REINSTALL
EXISTING "MIRROR" WHILE
PAINTING SURROUNDING
WALL.
DEMOLISH PORTION OF WALL FOR
INSTALLATION OF NEW DOOR
D2
D2
D2
V
IF
V
IF
H 360H
D13
D14
D12
D9
D12
D15 D16
LINE OF EXISTING
SOFFIT OVERHEAD
PATCH & REPAIR WALLS WHEN
RAISED FLOOR IS REMOVED TO
MATCH ADJACENT FINISH &
PREP FOR PAINT, TYP
D18
E.O. RAISED FLOOR
D12 D12
D12
SHEET NUMBER
SHEET NAME
PROJECT NO.
OWNER
PROJECT NAME
CONSULTANTS
© NEUMANN MONSON INC.
Unauthorized copying, disclosure or construction without written permission by Neumann Monson Inc. is prohibited.
ARCHITECT OF RECORD
Neumann Monson Architects
221 East College Street | Suite 303
Iowa City, Iowa 52240
319.338.7878
111 East Grand Avenue | Suite 105
Des Moines, Iowa 50309
515.339.7800
ISSUE
DATE DESCRIPTION
KCL Engineering
MEP
300 4th St.
West Des Moines, IA 50265
515.724.7938
T B
V e rs io n
.3
KEY PLAN
ALL ARCH SHEETS TO BE PRINTED IN COLOR
A-103
THIRD LEVEL
FLOOR PLANS
24.048
STATE OF IOWA
RFB No. 918604-01
9186.04 - DHS CC
STRATEGIC
SPACE PLANNING
HOOVER 3RD
FLOOR DEPT OF
ADMIN SERVICES
DAS No. 9186.04
50% CONSTRUCTION DOCUMENTS07/17/2024
95% CONSTRUCTION DOCUMENTS08/09/2024
100% CONSTRUCTION DOCUMENTS08/22/2024
1/8" = 1'-0"A1
THIRD LEVEL FLOOR PLAN
1/8" = 1'-0"C1
THIRD LEVEL DEMOLITION PLAN
DEMO NOTES
D1 FURNITURE VENDOR TO DEMOLISH WALL PRIOR TO START OF PROJECT. CONTRACTOR TO PATCH & REPAIR EXISTING FIXTURES & CEILING W/ ATTIC STOCK
PROVIDED BY OWNER.
D2 FURNITURE VENDOR TO DEMOLISH WALL PRIOR TO START OF PROJECT. CONTRACTOR TO PATCH & REPAIR EXISTING WALL.
D3 FURNITURE VENDOR TO DEMOLISH WALL PRIOR TO START OF PROJECT. CONTRACTOR TO PATCH & REPAIR EXISTING WINDOW / MULLION.
D4 DEMOLISH EXISTING OVERHEAD COILING DOOR. PATCH / FILL & FINISH WALL (MATCH ADJACENT).
D5 DEMOLISH EXISTING MAILBOXES. PATCH / FILL & FINISH WALL (MATCH ADJACENT).
D6 DEMOLISH EXISTING WINDOW. PATCH / FILL @ FINISH WALL (MATCH ADJACENT).
D7 DEMOLISH RAISED FLOOR & EXISTING RAMP IN OPEN OFFICE H370.
D8 DEMOLISH EXISTING LAMINATE FLOORING. INSTALL NEW LAMINATE TILE.
D9 REMOVE EXISTING CARPET. INSTALL NEW CARPET.
D10 REMOVE EXISTING WALL BASE & REPAIR WALL AS NEEDED.
D11 DEMOLISH EXISTING WOOD SHELF IN CORRIDOR H359.
D12 CONTRACTOR TO DEMOLISH EXISTING CHAIR RAILS & WALLPAPER. CONTRACTOR TO PATCH, PAINT & REPAIR WALLS.
D13 CONTRACTOR TO REMOVE EXISTING UNDERFLOOR SMOKE DETECTOR PANEL. PATCH & REPAIR EXISTING WALL.
D14 CONTRACTOR TO REMOVE EXISTING DEVICE SERVING DEVICES BELOW THE RAISED FLOOR. PATCH & REPAIR EXISTING WALL.
D15 CONTRACTOR TO DEMOLISH EXISTING COUNTERTOP & CASEWORK.
D16 REMOVE EXISTING FIRE EXTINGUISHER CABINET. CONTRACTOR TO PATCH W/ MTL STUD DRYWALL, FLUSH WITH SURROUNDING WALL. PAINT TO MATCH ADJACENT
MASONRY WALL COLOR.
D17 CONTRACTOR TO DEMOLISH EXISTING SLOTTED WOOD CEILING.
D18 REMOVE EXISTING MAIL SLOT(S) FOR INSTALLATION IN NEW LOCATION. PATCH / FILL & FINISH WALL - TO MATCH ADJACENT.
1. REMOVE ALL MEPT SYSTEM COMPONENTS WITHIN AREAS OF THE WORK OF THIS
CONTRACT THAT ARE NOTED AS ABANDONED OR TO BE ABANDONED BY THE WORK
OF THIS CONTRACT.
2. REFER TO MECHANICAL PLANS FOR LOCATIONS OF ADDITIONAL OPENINGS TO BE
CUT IN EXISTING WALLS FOR NEW DUCTWORK AND PIPING.
3. ALL EXISTING WALL SIGNAGE ARE TO BE PROTECTED WHILE PAINTING AND
REINSTALLED IN ITS ORIGINAL LOCATION UNLESS NOTED OTHERWISE.
4. ALL EXISTING DOOR HARDWARE (CLOSERS, REQUREST TO EXIT DEVICES, CARD
READERS, ETC.) ARE TO BE PROTECTED WHILE PAINTING DOORS & FRAMES.
5. ALL EXISTING STONE BASE TO BE PROTECTED / SALVAGED.
6. REFER TO MEP DRAWINGS FOR ADDITIONAL DEMOLITION OF DEVICE(S).
GENERAL DEMOLITION NOTES
EXISTING WOOD CEILING
CEILING LEGEND
EXISTING TYPE AR
CEILING (RADIANT PANEL)
EXISTING SLOT DIFFUSER
EXISTING TROFFER
5 6 7 8 10 11
B
C
A
12943
EXISTING / EXPOSED
WOOD BEAM
EXISTING
DRYWALL
SOFFIT
EXISTING
DRYWALL
SOFFIT
WALLS EXTEND TO
UNDERSIDE OF
CEILING, TYP
WALLS EXTEND TO
UNDERSIDE OF
CEILING, TYP
WALLS EXTEND TO
UNDERSIDE OF
CEILING, TYP
WALLS EXTEND TO
UNDERSIDE OF
CEILING, TYP
2'-0" 35'-0" 35'-0" 35'-0" 35'-0" 35'-0" 35'-0" 35'-0" 2'-0"
OFFICE
H342
OFFICE
H344
OFFICE
H346
OPEN OFFICE
H340
OPEN OFFICE
H352
CONFERENCE
ROOM
H362
CONFERENCE
ROOM
H364
OPEN OFFICE
H360
CONFERENCE
ROOM
H366
OFFICE
H368
OFFICE
H372
CONFERENCE
ROOM
H374
OPEN OFFICE
H370
EXISTING DRYWALL SOFFIT
NEW DRYWALL SOFFIT
EXISTING LIGHT FIXTURE
(EXTENDS OVER WALL)
APPROX LOCATION OF
WALLS (80" AFF) PROVIDED
BY FURNITURE CONRACT -
SHOWN FOR REFERENCE,
RED: EXISTING LIGHT FIXTURE
TO BE REMOVED & REPLACED
WITH OPAQUE PANEL FROM
OWNER PROVIDED ATTIC
STOCK, TYP
GREEN: EXISTING OPAQUE MTL
CEILING PANELS TO BE REPLACED
WITH LIGHT FIXTURE(S) FROM
OWNER PROVIDED ATTIC STOCK
OR FROM LIGHTS REMOVED
DURING THIS PROJECT, TYP
APPROX LOCATION OF
WALLS (80" AFF) PROVIDED
BY FURNITURE CONRACT -
SHOWN FOR REFERENCE,
APPROX LOCATION OF
WALLS (80" AFF) PROVIDED
BY FURNITURE CONRACT -
SHOWN FOR REFERENCE,
APPROX LOCATION OF
WALLS (80" AFF) PROVIDED
BY FURNITURE CONRACT -
SHOWN FOR REFERENCE,
PNT-4
(ALL EXISTING MTL
CEILING PANELS)
PNT-4
(ALL EXISTING MTL
CEILING PANELS)
PNT-4
(ALL EXISTING MTL
CEILING PANELS)
5 6 7 8 10 11
B
C
A
12943
D1 D1 D1
D4 D6
EXISTING / EXPOSED
WOOD BEAM
V
IF
DEMOLISH PORTION OF WALL FOR
INSTALLATION OF NEW DOOR
2'-0" 35'-0" 35'-0" 35'-0" 35'-0" 35'-0" 35'-0" 35'-0" 2'-0"
OFFICE
H342
OFFICE
H344
OFFICE
H346
OPEN OFFICE
H340
OPEN OFFICE
H352
OPEN OFFICE
H360
OPEN OFFICE
H370
OFFICE
H368
D17
SHEET NUMBER
SHEET NAME
PROJECT NO.
OWNER
PROJECT NAME
CONSULTANTS
© NEUMANN MONSON INC.
Unauthorized copying, disclosure or construction without written permission by Neumann Monson Inc. is prohibited.
ARCHITECT OF RECORD
Neumann Monson Architects
221 East College Street | Suite 303
Iowa City, Iowa 52240
319.338.7878
111 East Grand Avenue | Suite 105
Des Moines, Iowa 50309
515.339.7800
ISSUE
DATE DESCRIPTION
KCL Engineering
MEP
300 4th St.
West Des Moines, IA 50265
515.724.7938
T B
V e rs io n
.3
KEY PLAN
ALL ARCH SHEETS TO BE PRINTED IN COLOR
A-113
THIRD LEVEL
REFLECTED
CEILING PLANS
24.048
STATE OF IOWA
RFB No. 918604-01
9186.04 - DHS CC
STRATEGIC
SPACE PLANNING
HOOVER 3RD
FLOOR DEPT OF
ADMIN SERVICES
DAS No. 9186.04
50% CONSTRUCTION DOCUMENTS07/17/2024
95% CONSTRUCTION DOCUMENTS08/09/2024
100% CONSTRUCTION DOCUMENTS08/22/2024
1. AREAS WITH NO CEILING MATERIAL INDICATED ARE EXPOSED STRUCTURE.
2. CONTRACTOR TO REVIEW CEILING LAYOUT AS SHOWN AND NOTIFY ARCHITECT OF
ANY CONFLICTS WITH STRUCTURAL, ELECTRICAL, MECHANICAL, PLUMBING,
TELECOM, OR FIRE PROTECTION SYSTEMS, ETC. BEFORE PROCEEDING WITH
CONSTRUCTION.
3. CEILING ELEVATIONS ARE REFERENCED FROM THE FINISHED FLOOR OF THE ROOM IN
WHICH IT IS INSTALLED, UNLESS OTHERWISE NOTED.
4. THE REFLECTED CEILING PLAN(S) SHOW(S) AREAS TO RECEIVE NEW CEILING TILE
AND GRID. REMOVE EXISTING TILE AND GRID IN THESE AREAS.
5. INSTALL NEW CEILING TILE AND GRID AT THE SAME HEIGHT AS THE EXISTING CEILING
GRID UNLESS OTHERWISE NOTED.
6. REMOVE EXISTING CEILING TILES AND SUSPENSION GRID AS REQUIRED TO PERFORM
THE WORK OF THIS CONTRACT. REINSTALL TILES AND SUSPENSION SYSTEM. AT
COMPLETION OF THE WORK REPLACE ALL TILES, GRID, AND SUSPENSION SYSTEM
DAMAGED DURING THE EXECUTION OF THE WORK OF THIS CONTRACT. REPLACE ALL
TILES WITH HOLES, DISCOLORATION OR OTHER DEFECTS RESULTING FROM
REMOVAL OF PLUMBING, MECHANICAL, ELECTRICAL, OR TELECOM ITEMS, FIREALARM
DEVICES, CONDUIT, ETC. REMOVED AS PART OF THIS CONTRACT.
7. CUT GYPSUM TO CONTOURS OF ROOF DECK FLUTES AND SEAL WITH ACOUSTIC
SEALANT ON EACH SIDE.
8. ALL EXISTING METAL CEILING TILES & GRIDS ARE TO BE PAINTED (REMOVED &
PAINTED IF NECESSARY AND PLACED BACK IN THEIR ORIGINIAL LOCATION) UNLESS
OTHERWISE NOTED.
9. ALL EXISTING LIGHT TROFFERS & DIFFUSERS (TO BE PROTECTED DURING THE
PAINTING OF THE EXISTING CEILING TILES IF NECESSARY) ARE TO REMAIN IN THE
SPACE UNLESS OTHERWISE NOTED.
GENERAL RCP NOTES
1/8" = 1'-0"A1
THIRD LEVEL REFLECTED CEILING PLAN
1/8" = 1'-0"C1
THIRD LEVEL REFLECTED CEILING DEMOLITION PLAN
DEMO NOTES
D1 FURNITURE VENDOR TO DEMOLISH WALL PRIOR TO START OF PROJECT. CONTRACTOR TO PATCH & REPAIR EXISTING FIXTURES & CEILING W/ ATTIC STOCK
PROVIDED BY OWNER.
D2 FURNITURE VENDOR TO DEMOLISH WALL PRIOR TO START OF PROJECT. CONTRACTOR TO PATCH & REPAIR EXISTING WALL.
D3 FURNITURE VENDOR TO DEMOLISH WALL PRIOR TO START OF PROJECT. CONTRACTOR TO PATCH & REPAIR EXISTING WINDOW / MULLION.
D4 DEMOLISH EXISTING OVERHEAD COILING DOOR. PATCH / FILL & FINISH WALL (MATCH ADJACENT).
D5 DEMOLISH EXISTING MAILBOXES. PATCH / FILL & FINISH WALL (MATCH ADJACENT).
D6 DEMOLISH EXISTING WINDOW. PATCH / FILL @ FINISH WALL (MATCH ADJACENT).
D7 DEMOLISH RAISED FLOOR & EXISTING RAMP IN OPEN OFFICE H370.
D8 DEMOLISH EXISTING LAMINATE FLOORING. INSTALL NEW LAMINATE TILE.
D9 REMOVE EXISTING CARPET. INSTALL NEW CARPET.
D10 REMOVE EXISTING WALL BASE & REPAIR WALL AS NEEDED.
D11 DEMOLISH EXISTING WOOD SHELF IN CORRIDOR H359.
D12 CONTRACTOR TO DEMOLISH EXISTING CHAIR RAILS & WALLPAPER. CONTRACTOR TO PATCH, PAINT & REPAIR WALLS.
D13 CONTRACTOR TO REMOVE EXISTING UNDERFLOOR SMOKE DETECTOR PANEL. PATCH & REPAIR EXISTING WALL.
D14 CONTRACTOR TO REMOVE EXISTING DEVICE SERVING DEVICES BELOW THE RAISED FLOOR. PATCH & REPAIR EXISTING WALL.
D15 CONTRACTOR TO DEMOLISH EXISTING COUNTERTOP & CASEWORK.
D16 REMOVE EXISTING FIRE EXTINGUISHER CABINET. CONTRACTOR TO PATCH W/ MTL STUD DRYWALL, FLUSH WITH SURROUNDING WALL. PAINT TO MATCH ADJACENT
MASONRY WALL COLOR.
D17 CONTRACTOR TO DEMOLISH EXISTING SLOTTED WOOD CEILING.
D18 REMOVE EXISTING MAIL SLOT(S) FOR INSTALLATION IN NEW LOCATION. PATCH / FILL & FINISH WALL - TO MATCH ADJACENT.
EQEQEQEQ
09 6500;
RESILIENT BASE08 8000; GLAZING
COLUMN
EXISTING
COLUMN
EXISTING
12 3600; SSM
COUNTERTOP
09 6500;
RESILIENT BASE
REFRIGERATOR
NIC
20'-0"
4'-0"
24" 34" 112 24"
24" 34" 112 24"
C2
A-411
NEW FIRE
EXTINGUISHER &
BRACKET
EQ EQ
A F
F
09 6500;
RESILIENT BASE
EXPANSION JOINT REVEAL
NEW WALL EXTENTS
A
F F
MONITOR
NIC
@ MONITOR MOUNTING
4'-0"
09 6500;
RESILIENT BASE
06 1000; WD
BLOCKING
EQ EQ
*ALL AV / IT LOCATIONS TO BE COORDINATED W/ OWNER PRIOR TO INSTALLATION
UTILITIES
W D
B L
O C
K
IN
G
" UTILITIES
/4
EQ EQ
MONITOR NIC
@ MONITOR &
CAMERA MOUNTING
4'-0"4'-0"
09 6500;
RESILIENT BASE
06 1000; WD
BLOCKING
06 1000; WD
BLOCKING
A F
F
*ALL AV / IT LOCATIONS TO BE COORDINATED W/ OWNER PRIOR TO INSTALLATION
UTILITIES
06 1000; WD
BLOCKING
MONITOR NIC
@ MONITOR
MOUNTING
W D
B L
O C
K
IN
G
/4
UTILITIES
MONITOR
NIC
@ MONITOR & CAMERA
MOUNTING
06 1000; WD
BLOCKING
09 6500;
RESILIENT BASE
EQ EQ
4'-0"
A F
F
/2
*ALL AV / IT LOCATIONS TO BE COORDINATED W/ OWNER PRIOR TO INSTALLATION
UTILITIES
06 1000; WD
BLOCKING
W D
B L
O C
K
IN
G
/4 " 09 6500;
RESILIENT BASE
@ MONITOR &
CAMERA MOUNTING
A F
F
/2
EQEQ
06 1000; WD
BLOCKING
MONITOR
NIC
4'-0"
*ALL AV / IT LOCATIONS TO BE COORDINATED W/ OWNER PRIOR TO INSTALLATION
UTILITIES
06 1000; WD
BLOCKING
W D
B L
O C
K
IN
G
/4
A F
F
09 6500;
RESILIENT BASE
@ MONITOR MOUNTING
MONITOR
NIC
06 1000; WD
BLOCKING
4'-0"
*MONITOR SIZE & BLOCKING LOCATION TO BE
VERIFIED BY DAS PRIOR TO INSTALLATION.
EQ EQ
*ALL AV / IT LOCATIONS TO BE COORDINATED W/ OWNER PRIOR TO INSTALLATION
UTILITIES
W D
B L
O C
K
IN
G
/4
A
L4.3
EXISTING EXTERIOR
GLAZING & MULLION
EXTERIOR ALUMINUM
SILL BEYOND
END CAP
MULLION MATE
A L
IG
N
A L
IG
N
V
IF
09 2116; GYP BD
EDGE TRIM
LINE OF
EXISTING STONE
STOOL BEYOND
LINE OF
EXISTING STONE
SILL BEYOND
EXISTING STEEL
WINDOW
REINFORCEMENT - VIF
MINERAL WOOL
INSULATION
ALIGN
EQ EQ
24" 34" 112 24"
12 3600; SSM
COUNTERTOP
09 6500;
RESILIENT BASE
REINSTALL EXISTING FIRE
EXTINGUISHER & BRACKET
REMOVE EXISTING FIRE
EXTINGUISHER CABINET.
CONTRACTOR TO PATCH W/
DRYWALL, FLUSH WITH
SURROUNDING WALL. PAINT TO
MATCH ADJACENT MASONRY WALL
COLOR.
OWNER PROVIDED REFRIGERATOR
(RELOCATE AS SHOWN ON DRAWINGS)
24" 34" 112 24"
C2
A-411
OPEN
EXISTING FIRE EXTINGUISHER SIGNAGE
T Y
P
/8
M A
X
12 3600; SSM
COUNTERTOP
09 6500;
RESILIENT BASE
2'-0"
12 3600; SSM
BACKSPLASH
06 4100; PLASTIC
LAMINATE
A L
IG
N
SHEET NUMBER
SHEET NAME
PROJECT NO.
OWNER
PROJECT NAME
CONSULTANTS
© NEUMANN MONSON INC.
Unauthorized copying, disclosure or construction without written permission by Neumann Monson Inc. is prohibited.
ARCHITECT OF RECORD
Neumann Monson Architects
221 East College Street | Suite 303
Iowa City, Iowa 52240
319.338.7878
111 East Grand Avenue | Suite 105
Des Moines, Iowa 50309
515.339.7800
ISSUE
DATE DESCRIPTION
KCL Engineering
MEP
300 4th St.
West Des Moines, IA 50265
515.724.7938
T B
V e rs io n
.3
KEY PLAN
ALL ARCH SHEETS TO BE PRINTED IN COLOR
A-411
INTERIOR
ELEVATIONS
24.048
STATE OF IOWA
RFB No. 918604-01
9186.04 - DHS CC
STRATEGIC
SPACE PLANNING
HOOVER 3RD
FLOOR DEPT OF
ADMIN SERVICES
DAS No. 9186.04
50% CONSTRUCTION DOCUMENTS07/17/2024
95% CONSTRUCTION DOCUMENTS08/09/2024
100% CONSTRUCTION DOCUMENTS08/22/2024
1/4" = 1'-0"A4
OFFICE H360 - SOUTH
1/4" = 1'-0"B4
OFFICE H340 - NORTH
1/4" = 1'-0"C4
CONFERENCE ROOM H374 - SOUTH
1/4" = 1'-0"C5
CONFERENCE ROOM H366 - EAST
1/4" = 1'-0"D4
CONFERENCE ROOM H362 - SOUTH
1/4" = 1'-0"D5
CONFERENCE ROOM H364 - NORTH
1/4" = 1'-0"E5
CONFERENCE ROOM H342 - EAST
3" = 1'-0"A2
PLAN DTL @ INTERIOR PARTITION / EXTERIOR WALL / WINDOW
1/4" = 1'-0"E4
OPEN OFFICE H340 - SOUTH
1 1/2" = 1'-0"C2
SECTION DTL @ TYP CASEWORK
F N
PLAN VIEW
INDICATION OF
GLAZING OR
LOUVER, TYP.
VARIES
EXISTING LIGHT
V A
R
IE
S
E X
IS
T
IN
G
L
IG
H T
GHM1 HM3
S E
E S
C H
E D
U L E
2"
SCHEDULE
SEE 2"
S E
E S
C H
E D
U L E
2"
SCHEDULE
SEE 2"
HM2
S E
E S
C H
E D
U L E
2"
SCHEDULE
SEE
2"
SCHEDULE
SEE
2"
VIF
2"
EQEQEQ
20'-0"
HM4
EQ
1. ALL EXISTING SIGNAGE ON DOORS OR FRAMES TO BE PROTECTED DURING PAINTING AND / OR
REMOVED AND REINSTALLED IN THEIR ORIGINAL LOCATION UNLESS NOTED OTHERWISE.
2. INSTALL NEW DOOR NUMBER SIGNAGE ON FRAME.
3. ALL DOOR FRAMES TO BE PAINTED.
4. NEW DOOR HARDWARE TO MATCH EXISTING BRONZE FINISH.
NEW WORK TO BE COMPLETED
DOOR SCHEDULE NOTES
SHEET NUMBER
SHEET NAME
PROJECT NO.
OWNER
PROJECT NAME
CONSULTANTS
© NEUMANN MONSON INC.
Unauthorized copying, disclosure or construction without written permission by Neumann Monson Inc. is prohibited.
ARCHITECT OF RECORD
Neumann Monson Architects
221 East College Street | Suite 303
Iowa City, Iowa 52240
319.338.7878
111 East Grand Avenue | Suite 105
Des Moines, Iowa 50309
515.339.7800
ISSUE
DATE DESCRIPTION
KCL Engineering
MEP
300 4th St.
West Des Moines, IA 50265
515.724.7938
T B
V e rs io n
.3
KEY PLAN
ALL ARCH SHEETS TO BE PRINTED IN COLOR
A-601
DOOR
SCHEDULES,
ROOM FINISH
SCHEDULES
24.048
STATE OF IOWA
RFB No. 918604-01
9186.04 - DHS CC
STRATEGIC
SPACE PLANNING
HOOVER 3RD
FLOOR DEPT OF
ADMIN SERVICES
DAS No. 9186.04
50% CONSTRUCTION DOCUMENTS07/17/2024
95% CONSTRUCTION DOCUMENTS08/09/2024
100% CONSTRUCTION DOCUMENTS08/22/2024
DOOR SCHEDULE
No. ROOM
DOOR SIZE DOOR FRAME CARD
READER Existing NOTESWIDTH HEIGHT TYPE MAT FINISH GLAZE TYPE MAT FINISH GLAZE
H319-A OPEN OFFICE 3'-0" 7'-0" F WD ST HM1 HM PT-3 Yes 1,3
H340 OPEN OFFICE 3'-0" 7'-0" F WD ST HM1 HM PT-3 Yes 1,3
H342 OFFICE 3'-0" 7'-0" F WD ST HM1 HM PT-3 Yes 1,3
H344 OFFICE 3'-0" 7'-0" F WD ST HM1 HM PT-3 Yes 1,3
H346 OFFICE 3'-0" 7'-0" F WD ST HM3 HM PT-3 2'-0" SIDE LIGHT No 2,3,4
H348 ELEC 6'-0" 7'-0" F WD ST HM1 HM PT-3 Yes 1,3
H350 COMM 6'-0" 7'-0" F WD ST HM1 HM PT-3 Yes 1,3
H352 OPEN OFFICE 3'-0" 7'-0" F WD ST HM1 HM PT-3 Yes 1,3
H352-A OPEN OFFICE 3'-0" 7'-0" F WD ST HM1 HM PT-3 No 2,3,4
H353 OPEN OFFICE 3'-0" 7'-0" N WD ST YES HM2 HM PT-3 YES Yes 1,3
H359 OPEN OFFICE 3'-0" 7'-0" F WD ST HM2 HM PT-3 YES Yes 1,3
H359-A OPEN OFFICE 4'-0" 7'-0" N WD ST YES HM2 HM PT-3 YES Yes 1,3
H360 OPEN OFFICE 3'-6" 7'-0" G WD ST YES HM1 HM PT-3 HALF GLASS CUTOUT Yes 1,3
H360-A OPEN OFFICE 3'-6" 7'-0" N WD ST YES HM1 HM PT-3 Yes 1,3
H361 ELEC 6'-0" 7'-0" F WD ST HM1 HM PT-3 Yes 1,3
H362 CONFERENCE ROOM 3'-0" 7'-0" F WD ST HM3 HM PT-3 2'-0" SIDE LIGHT No 2,3,4
H363 COMM 6'-0" 7'-0" F WD ST HM1 HM PT-3 Yes 1,3
H364 CONFERENCE ROOM 3'-0" 7'-0" F WD ST HM3 HM PT-3 2'-0" SIDE LIGHT No 2,3,4
H365 STOR 3'-0" 7'-0" F WD ST HM1 HM PT-3 Yes 1,3
H366 CONFERENCE ROOM 3'-0" 7'-0" F WD ST HM3 HM PT-3 2'-0" SIDE LIGHT No 2,3,4
H368 OFFICE 3'-0" 7'-0" F WD ST HM3 HM PT-3 2'-0" SIDE LIGHT No 2,3,4
H372 OFFICE 3'-0" 7'-0" F WD ST HM3 HM PT-3 2'-0" SIDE LIGHT No 2,3,4
H374 CONFERENCE ROOM 3'-0" 7'-0" F WD ST HM3 HM PT-3 2'-0" SIDE LIGHT No 2,3,4
1/4" = 1'-0"
DOOR TYPES
1/4" = 1'-0"
FRAME TYPES
ROOM FINISH SCHEDULE
ROOM
FLOOR FINISH
BASE
FINISH
WALL
FINISH
SPECIALTY
WALL FINISH CEILING FINISH NOTESNo. NAME
H340 OPEN OFFICE CPT-1 / TILE-1 RB-1 PNT-1 PNT-2 - SEE B1/AF-103 EXISTING MTL PANEL (PNT-4) / PNT-1
GYP SOFFIT / EXISTING WOOD
CEILING
RES-1 IN KITCHENETTE AS
SHOWN ON AF-103
EXISTING WOOD CEILING
IN KITCHNETTE
H342 OFFICE CPT-1 RB-1 PNT-1 EXISTING MTL PANEL (PNT-4) / PNT-1
GYP SOFFIT
H344 OFFICE CPT-1 RB-1 PNT-1 EXISTING MTL PANEL (PNT-4)
H346 OFFICE CPT-1 RB-1 PNT-1 EXISTING MTL PANEL (PNT-4)
H348 ELEC CPT-1 RB-1 PNT-1 EXISTING MTL PANEL (PNT-4)
H350 COMM CPT-1 RB-1 PNT-1 EXISTING MTL PANEL (PNT-4)
H352 OPEN OFFICE CPT-1 RB-1 PNT-1 PNT-2 - SEE B1/AF-103 EXISTING MTL PANEL (PNT-4)
H353 CORRIDOR CPT-1 RB-1 PNT-1 EXISTING MTL PANEL (PNT-4)
H354 OPEN OFFICE CPT-1 RB-1 PNT-1 EXISTING MTL PANEL (PNT-4)
H359 CORRIDOR CPT-1 RB-1 PNT-1 EXISTING MTL PANEL (PNT-4)
H360 OPEN OFFICE CPT-1 RB-1 PNT-1 PNT-2 - SEE B1/AF-103 EXISTING MTL PANEL (PNT-4)
H361 ELEC CPT-1 RB-1 PNT-1 EXISTING MTL PANEL (PNT-4)
H362 CONFERENCE ROOM CPT-1 RB-1 PNT-1 EXISTING MTL PANEL (PNT-4)
H363 COMM CPT-1 RB-1 PNT-1 EXISTING MTL PANEL (PNT-4)
H364 CONFERENCE ROOM CPT-1 RB-1 PNT-1 EXISTING MTL PANEL (PNT-4)
H365 STOR CPT-1 RB-1 PNT-1 EXISTING MTL PANEL (PNT-4)
H366 CONFERENCE ROOM CPT-1 RB-1 PNT-1 EXISTING MTL PANEL (PNT-4)
H368 OFFICE CPT-1 RB-1 PNT-1 EXISTING MTL PANEL (PNT-4)
H370 OPEN OFFICE CPT-1 RB-1 PNT-1 EXISTING MTL PANEL (PNT-4) / PNT-1
GYP SOFFIT
H372 OFFICE CPT-1 RB-1 PNT-1 EXISTING MTL PANEL (PNT-4) / PNT-1
GYP SOFFIT
H374 CONFERENCE ROOM CPT-1 RB-1 PNT-1 EXISTING MTL PANEL (PNT-4) / PNT-1
GYP SOFFIT
* NEW SIGNAGE TO MATCH EXISTING (MATERIAL, SIZE,
FONT, ETC). SEE PHOTO ABOVE FOR REFERENCE.
* EXISTING DIRECTIONAL, INFORMATIONAL, AND ROOM
SIGNAGE TO BE REMOVED, SALVAGED, & REINSTALLED,
TYP. SEE PHOTO ABOVE FOR REFERENCE.
DOOR 360-A GLASS CUTOUT
FOR REFERENCE ONLY
TT
L
L LLL
L
L
L
L
5 6 7 8 10 11
B
C
2'-0" 35'-0" 35'-0" 35'-0" 35'-0" 35'-0" 35'-0" 35'-0" 2'-0"
A
12943
OFFICE
H372
CONFERENCE
ROOM
H374
OPEN OFFICE
H370
OFFICE
H368
OPEN OFFICE
H360
CONFERENCE
ROOM
H366
CONFERENCE
ROOM
H364
CONFERENCE
ROOM
H362
OPEN OFFICE
H352
OPEN OFFICE
H340
OFFICE
H346
OFFICE
H344
OFFICE
H342
ELEC
H348
COMM
H350
ELEC
H361
COMM
H363
STOR
H365
CORRIDORS H353 & H359 TO
RECIEVE NEW PAINT / WALL FINISH
E4
AF-103
INSTALL CARPET
BELOW
CASEWORK
PAINT SOFFIT
(PNT-1)
PAINT
SOFFIT
(PNT-1)
H 359-A
H
H
4H
H368 H372
H374
H
H
H
H
H366
H
H364
H362H352-A
H
H
H
0H
H -A
H340
H 360-A
E2
AF-103
E3
AF-103
E1
AF-103
OPEN OFFICE
H354
INSTALL RESILIENT
FLOORING UNDER
CASEWORK
ALIGN
09 6813; CARPET
TILE (CPT-1)
PNT-1
PNT-2
09 6500; RESILIENT
FLOORING (RES-1)
RES-1
LEVEL 3
28'-0"
09 6800; CARPET
09 6500;
RESILIENT
FLOORING
03 3000; CIP
CONC
(EXISTING TOPPING)
5 6 7 8 10 11
B
C
A
12943 2'-0" 35'-0" 35'-0" 35'-0" 35'-0" 35'-0" 35'-0" 35'-0" 2'-0"
OFFICE
H372
CONFERENCE
ROOM
H374OPEN OFFICE
H370
OFFICE
H368
OPEN OFFICE
H360
CONFERENCE
ROOM
H366
CONFERENCE
ROOM
H364
CONFERENCE
ROOM
H362
OPEN OFFICE
H352
OPEN OFFICE
H340
OFFICE
H346
OFFICE
H344
OFFICE
H342
ELEC
H348
COMM
H350
ELEC
H361
COMM
H363
STOR
H365
H 359-A
H 342 H
H
H368 H372
H374
H
H
H
H
H366
H
H364
H362H352-A
H
H
H
H -A
H340
H 360-A
H
OPEN OFFICE
H354
APPROX LOCATION OF
WALLS (80" AFF) PROVIDED
BY FURNITURE CONRACT -
SHOWN FOR REFERENCE,
APPROX LOCATION OF
WALLS (80" AFF) PROVIDED
BY FURNITURE CONRACT -
SHOWN FOR REFERENCE,
APPROX LOCATION OF
WALLS (80" AFF) PROVIDED
BY FURNITURE CONRACT -
SHOWN FOR REFERENCE,
APPROX LOCATION OF
WALLS (80" AFF) PROVIDED
BY FURNITURE CONRACT -
SHOWN FOR REFERENCE,
LEVEL 3
28'-0"
09 6813; CARPET TILE (NEW)
EXISTING CARPET
EXISTING CONCRETE
TOPPING
09 6566;
TRANSITION STRIP
EXISTING WOOD DOOR
LEVEL 3
28'-0"
09 6813; CARPET TILE (NEW)
EXISTING CONCRETE
TOPPING
09 6566;
TRANSITION STRIP
LEVEL 3
28'-0"
EXISTING CONCRETE
TOPPING
09 6566;
TRANSITION STRIP
09 6500; RESILIENT
FLOORING
EXISTING RESILIENT
FLOORING
EXISTING WOOD DOOR
MATERIAL SPECIFICATIONS - BASIS OF DESIGN
Key Name Material Name Manufacturer Description Comments SSM-1 12 3600 - Solid Surface Corian Solid Surface Glacier White COUNTERTOPS / BACKSPLASH
PNT-1 09 9000 - Paint Sherwin Williams SW7641, Colonnade Gray WALL PAINT, COLUMNS
PNT-2 09 9000 - Paint Sherwin Williams SW6716, Dancing Green WALL ACCENT PAINT
PNT-3 09 9000 - Paint Sherwin Williams SW7642, Pavestone DOOR FRAMES
PNT-4 09 9000 - Paint Sherwin Williams Pro Industrial Waterborne Acrylic Drywall Flat (B42W02181 White) CEILING PAINT
CPT-1 09 6813 Carpet Tile Shaw Contract Group Collection: Diffuse + Disperse, Riverfront 75335, Installation:
Quarter Turn
RB-1 09 6513 Resilient Base Johnsonite Silver Gray 55
RES-1 09 6500 - Resilient Flooring Mohawk Group Large and Local Cloudland 958 KITCHENETTE
PLAM-1 06 4100 - Plastic Laminate Formica Dover White - Matte Finish CASEWORK
1/8" = 1'-0"
FINISH FLOOR LEGEND
SHEET NUMBER
SHEET NAME
PROJECT NO.
OWNER
PROJECT NAME
CONSULTANTS
© NEUMANN MONSON INC.
Unauthorized copying, disclosure or construction without written permission by Neumann Monson Inc. is prohibited.
ARCHITECT OF RECORD
Neumann Monson Architects
221 East College Street | Suite 303
Iowa City, Iowa 52240
319.338.7878
111 East Grand Avenue | Suite 105
Des Moines, Iowa 50309
515.339.7800
ISSUE
DATE DESCRIPTION
KCL Engineering
MEP
300 4th St.
West Des Moines, IA 50265
515.724.7938
T B
V e rs io n
.3
KEY PLAN
ALL ARCH SHEETS TO BE PRINTED IN COLOR
AF-103
THRID LEVEL
FLOOR FINISH
PLAN
24.048
STATE OF IOWA
RFB No. 918604-01
9186.04 - DHS CC
STRATEGIC
SPACE PLANNING
HOOVER 3RD
FLOOR DEPT OF
ADMIN SERVICES
DAS No. 9186.04
50% CONSTRUCTION DOCUMENTS07/17/2024
95% CONSTRUCTION DOCUMENTS08/09/2024
100% CONSTRUCTION DOCUMENTS08/22/2024
1/8" = 1'-0"B1
THIRD LEVEL FLOOR FINISH PLAN
3" = 1'-0"E4
TRANSITION DTL @ CRPT - RES
1/8" = 1'-0"A1
THIRD LEVEL FURNITURE PLAN (FOR REFERENCE)
3" = 1'-0"E3
TRANSITION DTL @ CRPT - CRPT
3" = 1'-0"E2
TRANSITION DTL @ CRPT - CONC
3" = 1'-0"E1
TRANSITION DTL - RES - RES
COMMUNICATIONS - TELECOM SYSTEMS:
O
FO
I
RACKS, FRAMES AND ENCLOSURES
PLYWOOD BACKBOARDS
COPPER BACKBONE CABLING
OPTICAL FIBER BACKBONE CABLING
COAXIAL BACKBONE CABLING
COPPER HORIZONTAL CABLING
OPTICAL FIBER HORIZONTAL CABLING
COAXIAL BACKBONE CABLING
DATA COMMUNICATIONS SWITCHES AND HUBS
DATA COMMUNICATIONS WIRELESS ACCESS POINTS
VOICE COMMUNICATIONS SWITCHING AND ROUTING EQUIPMENT
CABLE MANAGEMENT
UNINTERRUPTIBLE POWER SUPPLIES (RACK MOUNT)
COMMUNICATIONS - AUDIO-VISUAL SYSTEMS:
FLAT PANEL DISPLAY(S)
MULTI-TOUCH DISPLAY(S)
MEDIA PLAYER(S)
HEAD-END EQUIPMENT
PUBLIC ADDRESS SYSTEM
SOUND MASKING / SPEECH PRIVACY SYSTEM - ADD ALTERNATE #1
INTERCOMMUNICATIONS SYSTEM
WIRED / WIRELESS CLOCK SYSTEM
NURSE CALL / CODE BLUE SYSTEM
COMMUNICATIONS - DISTRIBUTED SYSTEMS:
DISTRIBUTED ANTENNA SYSTEM
MASTER ANTENNA / COMMUNITY ANTENNA TELEVISION DISTRIBUTION
SECURITY - ACCESS CONTROL:
SECURITY MANAGEMENT SYSTEM - HEAD END COMPONENTS
ROUGH-IN, PATHWAYS AND SLEEVES
DOOR STATION(S)
HEAD END EQUIPMENT AND COMPONENTS
SECURITY MANAGEMENT SYSTEM - FIELD DEVICES
SECURITY MANAGEMENT SYSTEM - ELECTRIFIED DOOR HARDWARE
ROUGH-IN, PATHWAYS AND SLEEVES
ROUGH-IN, PATHWAYS AND SLEEVES
DISPLAY TECHNOLOGY MOUNTING HARDWARE
ROUGH-IN, PATHWAYS AND SLEEVES
ROUGH-IN, PATHWAYS AND SLEEVES
SECURITY - VIDEO INTERCOM:
ROUGH-IN, PATHWAYS AND SLEEVES
SECURITY - VIDEO SURVEILLANCE:
CAMERA(S)
HEAD END EQUIPMENT AND COMPONENTS
SECURITY - INTRUSION DETECTION:
ROUGH-IN, PATHWAYS AND SLEEVES
FIELD DEVICES (MOTION DETECTORS, GLASS BREAKS, DOOR SWITCHES)
HEAD END EQUIPMENT AND COMPONENTS
SAFETY - FIRE DETECTION AND ALARM:
ROUGH-IN, PATHWAYS AND SLEEVES
INITIATING FIELD DEVICES (SMOKE, MANUAL PULL, MONITOR MODULES)
NOTIFICATION APPLIANCES (HORNS, STROBES, SPEAKERS)
MISCELLANEOUS DEVICES (RELAYS, TEST STATION, ANNUNCIATOR)
TECHNOLOGY RESPONSIBILITY MATRIX
PROVISION RESPONSIBILITIES DEFINED
SECURITY MANAGEMENT SYSTEM - ALL CABLING
PROJECTOR(S)
OFOI
OFCI
CFCI
CFOI
OWNER FURNISHED & OWNER INSTALLED
OWNER FURNISHED & CONTRACTOR INSTALLED
CONTRACTOR FURNISHED & CONTRACTOR INSTALLED
CONTRACTOR FURNISHED & OWNER INSTALLED
GENERAL NOTE:
A. MATRIX IS NOT INTENDED TO BE EXHAUSTIVE TO COVER ALL MATERIALS NECESSARY FOR
SCOPE AND SHOULD ONLY BE USED TO QUICKLY IDENTIFY SYSTEMS AND RELATED
INFRASTRUCTURE INSIDE AND OUTSIDE THE BID OF THIS PROJECT. ANY ITEMS FURNISHED
OR INSTALLED BY THE BIDDING CONTRACTOR SHALL COVER ALL REQUIRED APPURTENANCES
NECESSARY FOR A COMPLETE SYSTEM. THIS SHALL INCLUDE BUT NOT BE LIMITED TO,
EQUIPMENT, ACCESSORIES, TERMINATIONS, TERMINATION COMPONENTS, ALL FINAL
CORDAGE CONNECTIVITY, SOFTWARE, PROGRAMMING, AND THE LABOR TO INSTALL.
O
FC
I
C
FC
I
C
FO
I
N/A N/A N/A N/A
N/A N/A N/A N/A
N/A N/A N/A N/A
N/A N/A N/A N/A
N/A N/A N/A N/A
N/A N/A N/A N/A
N/A N/A N/A N/A
N/A N/A N/A N/A
N/A N/A N/A N/A
N/A N/A N/A N/A
N/A N/A N/A N/A
N/A N/A N/A N/A
N/A N/A N/A N/A
N/A N/A N/A N/A
N/A N/A N/A N/A
N/A N/A N/A N/A
N/A N/A N/A N/A
N/A N/A N/A N/A
N/A N/A N/A N/A
N/A N/A N/A N/A
N/A N/A N/A N/A
N/A N/A N/A N/A
N/A N/A N/A N/A
N/A N/A N/A N/A
N/A N/A N/A N/A
N/A N/A N/A N/A
N/A N/A N/A N/A
N/A N/A N/A N/A
1. EXTEND THE EXISTING SIMPLEX 4100U FIRE DETECTION AND ALARM SYSTEM TO
LOCATIONS ILLUSTRATED ON THE DRAWINGS.
2. FIRE ALARM ITEMS AND DEVICES ARE SHOWN IN SUGGESTED LOCATIONS. FINAL
LAYOUTS, LOCATIONS, AND QUANTITIES SHALL BE IN ACCORDANCE WITH APPLICABLE
CODES, MANUFACTURER’S RECOMMENDATIONS, AND EQUIPMENT LISTINGS.
COORDINATE LOCATIONS WITH LIGHTING AND AIR HANDLING SYSTEMS.
3. ALL FIRE ALARM CIRCUITRY IN EXPOSED CEILING SPACES SHALL BE IN ¾” CONDUIT PER
SPECIFICATIONS. EXPOSED CABLING SHALL NOT BE ACCEPTED.
4. ALL CONCEALED, ACCESSIBLE CEILING TILE LOCATIONS SHALL BE ALLOWED TO HAVE
OPEN AIR CABLING INSTALLED. PROVIDE J-HOOKS, BRIDLE RINGS AND ASSOCIATED
CABLE SUPPORTS TO KEEP INFRASTRUCTURE MANAGED AND OFF OF THE CEILING TILE.
5. ELECTRICAL CONTRACTOR SHALL PROVIDE FIRESTOPPING AT ALL PENETRATIONS PER
SPECIFICATION.
FIRE DETECTION & ALARM NOTES
1. ALL EXISTING DEVICES AND DEVICE LOCATIONS WERE MADE BY CASUAL FIELD
OBSERVATION. CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING SYSTEM
COMPONENTS AND DEVICE LOCATIONS.
2. PROVIDE LABOR AND MATERIALS TO REMOVE ELECTRICAL FACILITIES AND CLEAR THE
AREA TO RECEIVE THE NEW WORK TO BE PROVIDED UNDER THIS CONTRACT.
3. SYSTEMS SCHEDULED TO BE REMOVED SHALL BE DONE SO IN THEIR ENTIRETY.
ABAND…