Restated_Exhibit_A._MDAD_Sites_and_Equipment_Location.xlsx
XLSX spreadsheet 40 KB Posted
- Attached to
- MDAD HVAC CHILLERS
- Solicitation number
- EVN0060585
- Issued by
- Miami-Dade County, Fruitville CDP, Florida
About this file
This is a restated exhibit detailing HVAC chiller sites and equipment locations for the Miami-Dade Aviation Department (MDAD) full-service chillers maintenance contract, organized across five geographic zones. The document provides comprehensive equipment inventories for 30 sites containing chiller systems, including original equipment manufacturer specifications, model numbers, serial numbers, installation years, tonnage capacities, and refrigerant types and vintages. Auxiliary equipment specifications are detailed for each site, including water treatment pumps, cooling towers, condenser water pumps, chilled water pumps, and air compressors with horsepower ratings and quantities. The associated ITB EVN0060585 solicitation establishes a ten-year (120-month) contract term commencing on the first calendar day following Board of County Commissioners approval. Bids are due October 14, 2026, with a pre-bid conference scheduled for September 8, 2026 at 9:00 a.m. at Miami International Airport Building 5A. Site visits are available September 8, 9, and 10, 2026 for different facility locations. Bidders may submit proposals for one, multiple, or all five zones, but each bidder may be awarded only one zone, with award made independently and sequentially to the lowest responsive, responsible bidder.
Pricing is structured on a unit-price basis through the INFORMS electronic system, with all costs including labor, materials, equipment, mobilization, and disposal embedded in bid prices. Initial prices remain fixed for twelve months from the solicitation end date, with subsequent adjustments based on the Consumer Price Index for the Miami-Fort Lauderdale-West Palm Beach area. The contract includes an allowance account not to exceed 20 percent of total contract value for contingencies, price adjustments, additional sites, services, and replacement parts. Scope includes comprehensive maintenance, preventive service, repairs, emergency response, chiller overhauls, water treatment programs, and lifecycle management for all HVAC systems, chillers, cooling towers, water treatment equipment, and associated auxiliary systems. Bidders must possess a Florida Mechanical Contractor or Class A Air Conditioning Contractor license; EPA Universal Refrigerant Certification for technicians; ASNT NDT Level II and III certifications for testing personnel; and documented references demonstrating experience with HVAC chillers, water treatment, and oil analysis services. Insurance requirements include $1,000,000 commercial general liability per occurrence (or $5,000,000 for airfield operations), $1,000,000 automobile liability, and $2,000,000 environmental liability. All bid documents and questions must be submitted electronically through INFORMS before the October 14, 2026 deadline.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Zone 1
| ZONE 1 | ||||||||||
| Site # | Equipment Location | HVAC - Chiller | ||||||||
| 20 | Building 2122/719 | |||||||||
| DHS BLDG. | Chiller # | Original Equipment Manufacture | Equipment Type | Model # | Serial # | Year Installed | Tonnage | Refrigerant Types & Vintages | ||
| 1 | York Air | Scroll | YLAA0070 | 2GMA021451 | 2013 | 70 | R-22 R410A | |||
| 2 | York Air | Scroll | YLAA0070 | 2GMA021450 | 2013 | 70 | R-22 R410A | |||
| 3 | York Air | Scroll | YLAA0070 | 2GMA021452 | 2013 | 70 | R-410A | |||
| 4 | York Air | Scroll | YLAA0070 | 2GMA021449 | 2013 | 70 | R-410A | |||
| Auxiliary Equipment - Water Treatment Services | ||||||||||
| Equipment Type | Original Equipment Manufacture | Pump # | Quantity # | Type / Horse Power | ||||||
| Chilled H2O Pump | N/A | 2 | 2 | 7.5 | ||||||
| N/A | 2 | 2 | 5 | |||||||
| Air Compressor | N/A | 1 | 1 | Duplex / 3 |
| Site # | Equipment Location | HVAC - Chiller | |||||||
| 21 | MIA MIC Station | Chiller # | Original Equipment Manufacture | Equipment Type | Model # | Serial # | Year Installed | Tonnage | Refrigerant Types & Vintages |
| 1 | Trane Air Cooled | Screw | RTAA1254YT01A3 | U09F04340 | 2009 | 125 | R-134A | ||
| 2 | Trane Air Cooled | Screw | RTAA1254YT01A3 | U09F04343 | 2009 | 125 | R-134A | ||
| 3 | Trane Air Cooled | Screw | RTAA1254YT01A3 | U09F04341 | 2009 | 125 | R-134A | ||
| Auxiliary Equipment - Water Treatment Services | |||||||||
| Equipment Type | Original Equipment Manufacture | Pump # | Quantity # | Type / Horse Power | |||||
| Chilled H2O Pump | N/A | N/A | 3 | 20 |
| Site # | Equipment Location | HVAC - Chiller | |||||||
| 23 | Building 716A | Chiller # | Original Equipment Manufacture | Equipment Type | Model # | Serial # | Year Installed | Tonnage | Refrigerant Types & Vintages |
| 1 | QUANTECH | Scroll | QTC3070TSE46XFBSDTXAXXBLXCXX44SE1XXX | 82012L31944309 | 2023 | 70 | R-410A | ||
| 2 | Trane Air Cooled | Screw | CGAM070F2R03AXB2A1B1A1AXXA1A1A4X XXXX | U19A72485 | 2020 | 70 | R-410A | ||
| Auxiliary Equipment - Water Treatment Services | |||||||||
| Equipment Type | Original Equipment Manufacture | Pump # | Quantity # | Type / Horse Power | |||||
| Pump | WEG 3 HP / 208 230-460V / 1765 RPM / 182-4T Frame | 1 | 1 | N/A | |||||
| WEG 3 HP / 208 230-460V / 1765 RPM / 182-4T Frame | 2 | 1 | N/A | ||||||
| Chilled H2O Pump | N/A | 2 | 2 | 7.5 | |||||
| Air Compressor | N/A | 1 | 1 | Duplex / 1.5 |
| Site # | Equipment Location | HVAC - Chiller | ||||||||
| 24 | Building 716B | |||||||||
| AOA | Chiller # | Original Equipment Manufacture | Equipment Type | Model # | Serial # | Year Installed | Tonnage | Refrigerant Types & Vintages | ||
| 1 | Carrier Air Cooled | Reciprocal | 30RAP0206 | 2016Q56622 | 2016 | 20 | R-410A | |||
| Auxiliary Equipment - Water Treatment Services | ||||||||||
| Equipment Type | Original Equipment Manufacture | Pump # | Quantity # | Type / Horse Power | ||||||
| Chilled H2O Pump | N/A | 2 | 2 | 1.5 | ||||||
| Site # | Equipment Location | HVAC - Chiller | ||||||||
| 29 | Miami Intermodal Center (MIC) |
3811 NW 21 ST
| Miami, FL 33142 | Chiller # | Original Equipment Manufacture | Equipment Type | Model # | Serial # | Year Installed | Tonnage | Refrigerant Types & Vintages | ||
| 1 | Trane | Screw | RTAA 1254 YT01 A3L0 NBPC | U09F04342 | N/A | 125 | R-22 | |||
| Auxiliary Equipment - Water Treatment Services | ||||||||||
| Equipment Type | Original Equipment Manufacture | Pump # | Quantity # | Type / Horse Power | ||||||
| Chilled H2O Pump | N/A | 1 | 1 | 20 |
Zone 2
| ZONE 2 | ||||||||||
| Site # | Equipment Location | HVAC - Chiller | ||||||||
| 1 | Building 5A | Chiller # | Original Equipment Manufacture | Equipment Type | Model # | Serial # | Year Installed | Tonnage | Refrigerant Types & Vintages | |
| 1 | Trane | Centrifugal | CVHE450 | L13J04013 | 2013 | 325 | R-123 | |||
| 2 | Trane | Centrifugal | CVHE450 | L18D01882 | 2018 | 325 | R-123 | |||
| Auxiliary Equipment - Water Treatment Services | ||||||||||
| Equipment Type | Original Equipment Manufacture | Pump # | Quantity # | Type / Horse Power | ||||||
| Pump | TECO 30 HP / 230-460 V / 1770 RPM / 286 T Frame | 1 | 1 | N/A | ||||||
| MARATHON 30 HP / 230-460 V / 1775 RPM / 286 T Frame | 2 | 1 | N/A | |||||||
| Cooling Tower | Evapco Stainless | 1 - 2 Cell | 1 | N/A | ||||||
| Condenser H2O | N/A | 2 | 2 | 30 | ||||||
| Chilled H2O Pumps | N/A | 2 | 2 | 20 | ||||||
| Air Compressor | N/A | 1 | 1 | Duplex / 5 | ||||||
| Site # | Equipment Location | HVAC - Chiller | ||||||||
| 2 | Building 33 | Chiller # | Original Equipment Manufacture | Equipment Type | Model # | Serial # | Year Installed | Tonnage | Refrigerant Types & Vintages | |
| 1 | Trane | Centrifugal | CVHE500 | L10D02228 | 2010 | 325 | R-123 | |||
| 2 | Trane | Centrifugal | CVHE500 | L13L04840 | 2013 | 325 | R-123 | |||
| Auxiliary Equipment - Water Treatment Services | ||||||||||
| Equipment Type | Original Equipment Manufacture | Pump # | Quantity # | Type / Horse Power | ||||||
| Pump | Allis-Chalmers #8000 / 1080156 / 8x6x12L / 10.5 " IMP | |||||||||
| BALDOR 40 HP / 230-460V / 1775 RPM / 324 T Frame / TEFC | 1 | 1 | N/A | |||||||
| Allis-Chalmers #8000 / 1080156 / 8x6x12L / 10.5 " IMP | ||||||||||
| BALDOR 40 HP / 230-460V / 1775 RPM / 324 T Frame / TEFC | 2 | 1 | N/A | |||||||
| Cooling Tower | Evapco Stainless | 1 - 2 Cell | 2 | N/A | ||||||
| Condenser H2O | N/A | 2 | 2 | 30 | ||||||
| Chilled H2O Pumps | N/A | 2 | 2 | 25 | ||||||
| Air Compressor | N/A | 1 | 1 | Duplex / 5 |
| Site # | Equipment Location | HVAC - Chiller | ||||||||
| 4 | Building 60 | |||||||||
| AOA | Chiller # | Original Equipment Manufacture | Equipment Type | Model # | Serial # | Year Installed | Tonnage | Refrigerant Types & Vintages | ||
| 1 | Trane | Centrifugal | CVHE500 | L08J04345 | 2008 | 400 | R-123 | |||
| 2 | Trane | Centrifugal | CVHE500 | L08J04351 | 2008 | 400 | R-123 | |||
| Auxiliary Equipment - Water Treatment Services | ||||||||||
| Equipment Type | Original Equipment Manufacture | Pump # | Quantity # | Type / Horse Power | ||||||
| Cooling Tower | Evapco Stainless | 2 | 2 | N/A | ||||||
| Condenser H2O | N/A | 3 | 3 | 25 | ||||||
| Chilled H2O Pumps | N/A | 2 | 2 | 7.5 | ||||||
| Air Compressor | N/A | 1 | 3 | Duplex / 2 |
| Site # | Equipment Location | HVAC - Chiller | |||||||
| 6 | Building 707 | Chiller # | Original Equipment Manufacture | Equipment Type | Model # | Serial # | Year Installed | Tonnage | Refrigerant Types & Vintages |
| 1 | York | Screw | YMC2 - S0879AAS | SGFM - 192320 | 2019 | 250 | R-134A | ||
| 2 | York | Screw | YMC2 - S0879AAS | SGFM - 192460 | 2019 | 250 | R-134A | ||
| 3 | York | Screw | YMC2 - S0879AAS | SGFM - 192600 | 2019 | 250 | R-134A | ||
| Auxiliary Equipment - Water Treatment Services | |||||||||
| Equipment Type | Original Equipment Manufacture | Pump # | Quantity # | Type / Horse Power | |||||
| Pump | AURORA 93-13221-1 / 411 BF / 4X5X15 / 750 GPM / 140 FT. HD WEG 40 HP / 230-460 V / 1775 RPM / 324-6T Frame / TEFC | 1 | 1 | N/A | |||||
| AURORA 93-13221-2 / 411 BF / 4X5X15 / 750 GPM / 140 FT. HD US MOTOR 40 HP / 230-460 V / 1780 RPM / 324 Frame / ODP | 2 | 1 | N/A | ||||||
| Cooling Tower | Marley | 3 | 3 | N/A | |||||
| Condenser H2O | N/A | 3 | 3 | 15 | |||||
| Chilled H2O Pumps | N/A | 3 | 3 | 7.5 | |||||
| Air Compressor | N/A | 1 | 1 | Duplex / 5 | |||||
| Site # | Equipment Location | HVAC - Chiller | |||||||
| 22 | GAC Building 841 | Chiller # | Original Equipment Manufacture | Equipment Type | Model # | Serial # | Year Installed | Tonnage | Refrigerant Types & Vintages |
| 1 | QUANTECH | Scroll | QTC3050THE46XCBSDTXAXXBLXCXX44SE1XXX | C06B00854 | 2022 | 50 | R-410A | ||
| Auxiliary Equipment - Water Treatment Services | |||||||||
| Equipment Type | Original Equipment Manufacture | Pump # | Quantity # | Type / Horse Power | |||||
| Chilled H2O Pumps | N/A | 2 | 2 | 3 | |||||
| Site # | Equipment Location | HVAC - Chiller | |||||||
| 27 | Building 101 | Chiller # | Original Equipment Manufacture | Equipment Type | Model # | Serial # | Year Installed | Tonnage | Refrigerant Types & Vintages |
| 1 | Carrier | Scroll | 30RAP02063C00910 | 1122Q72798 | 2011 | 19 | R-410A | ||
| Auxiliary Equipment - Water Treatment Services | |||||||||
| Equipment Type | Original Equipment Manufacture | Pump # | Quantity # | Type / Horse Power | |||||
| Chilled H2O Pumps | N/A | 1 | 1 | 1 |
Zone 3
| ZONE 3 | ||
| Site # | Equipment Location | HVAC - Chiller |
| 14 | Concourse D East |
PCA Plant I
| AOA | Chiller # | Original Equipment Manufacture | Equipment Type | Model # | Serial # | Year Installed | Tonnage | Refrigerant Types & Vintages | ||
| 1 | York | Centrifugal | YKGPECQ7-ELHS | SGLM-347980 | 2024 | 367 | R-134A | |||
| 2 | York | Centrifugal | YKGPECQ7-ELHS | SHLM-360800 | 2024 | 367 | R-134A | |||
| 3 | York | Centrifugal | YKGPECQ7-ELHS | SHLM-375200 | 2024 | 367 | R-134A | |||
| Auxiliary Equipment - Water Treatment Services | ||||||||||
| Equipment Type | Original Equipment Manufacture | Pump # | Quantity # | Type / Horse Power | ||||||
| Pump | AURORA #B5-S48684-1 / 411BF / 6X8X18A / 750 GPM / 330 FT. HD. | |||||||||
| WEG 150 HP / 460 V / 1785 RPM / 444-5TS Frame / ODP 1.15 SF | 1 | 1 | N/A | |||||||
| AURORA #B5-S48684-2 / 411BF / 6X8X18A / 750 GPM / 330 FT. HD. | ||||||||||
| WEG 150 HP / 460 V / 1785 RPM / 444-5TS Frame / ODP 1.15 SF | 2 | 1 | N/A | |||||||
| Condenser H2O | N/A | 3 | 3 | 20 | ||||||
| Chilled H2O Pumps | N/A | 2 | 2 | 40 |
| Site # | Equipment Location | HVAC - Chiller | ||||||||
| 15 | Concourse D Central PCA Plant II | |||||||||
| AOA | Chiller # | Original Equipment Manufacture | Equipment Type | Model # | Serial # | Year Installed | Tonnage | Refrigerant Types & Vintages | ||
| 1 | Trane | Screw | RTH1C1F | U02H06219 | 2006 | 200 | R-22 | |||
| 2 | Trane | Screw | RTH1C1F | U02H06220 | 2006 | 200 | R-22 | |||
| 3 | Trane | Screw | RTH1C1F | U02H06226 | 2006 | 200 | R-22 | |||
| Auxiliary Equipment - Water Treatment Services | ||||||||||
| Equipment Type | Original Equipment Manufacture | Pump # | Quantity # | Type / Horse Power | ||||||
| Pump | AURORA #B5-B48634-1 / 411BF / 5X6X17 / 1000 GPM / 240 FT. HD. | |||||||||
| BALDOR 125 HP / 460 V / 1775 RPM / 405TS Frame / ODP 1.15 SF | 1 | 1 | N/A | |||||||
| AURORA #B5-B48634-2 / 411BF / 5X6X17 / 1000 GPM / 240 FT. HD. | ||||||||||
| WEG 125 HP / 460 V / 1780 RPM / 404-5TS Frame / ODP 1.15 SF | 2 | 1 | N/A | |||||||
| Condenser H2O | N/A | 3 | 3 | 15 | ||||||
| Chilled H2O Pumps | N/A | 2 | 2 | 15 | ||||||
| Air Compressor | N/A | 1 | 1 | Duplex / 7.5 |
| Site # | Equipment Location | HVAC - Chiller | ||||||||
| 16 | Concourse D Extension PCA Plant III | |||||||||
| AOA | Chiller # | Original Equipment Manufacture | Equipment Type | Model # | Serial # | Year Installed | Tonnage | Refrigerant Types & Vintages | ||
| 1 | Trane | Screw | RTHC1C2FOH0G1L3G | U02H06227 | 2004 | 200 | R-134A | |||
| 2 | Trane | Screw | RTHC1C2FOH0G1L3G | U02J06229 | 2004 | 200 | R-134A | |||
| 3 | Trane | Screw | RTHC1C2FOH0G1L3G | U02H06228 | 2004 | 200 | R-134A | |||
| Auxiliary Equipment - Water Treatment Services | ||||||||||
| Equipment Type | Original Equipment Manufacture | Pump # | Quantity # | Type / Horse Power | ||||||
| Pump | AURORA #95-07610-1 / 411 BF / 4X5X15 / 800 GPM / 174 FT. HD | |||||||||
| MARATHON 50 HP / 460 V / 1770 / 326 T Frame / TEFC/ 1.15 SF | 1 | 1 | N/A | |||||||
| AURORA #95-07610-2 / 411 BF / 4X5X15 / 800 GPM / 174 FT. HD | ||||||||||
| MARATHON 50 HP / 460 V / 1770 / 326 T Frame / TEFC/ 1.15 SF | 2 | 1 | N/A | |||||||
| Condenser H2O | N/A | 3 | 3 | 30 | ||||||
| Chilled H2O Pumps | N/A | 2 | 2 | 60 | ||||||
| Air Compressor | N/A | 1 | 1 | Duplex / 10 |
| Site # | Equipment Location | HVAC - Chiller | ||||||||
| 17 | Concourse J PCA Plant IV | |||||||||
| AOA | Chiller # | Original Equipment Manufacture | Equipment Type | Model # | Serial # | Year Installed | Tonnage | Refrigerant Types & Vintages | ||
| 1 | Trane | Screw | RTHDUD1F | U04M09166 | 2004 | 200 | R-22 | |||
| 2 | Trane | Screw | RTHDUD1F | U04M09167 | 2004 | 200 | R-22 | |||
| 3 | Trane | Screw | RTHDUD1F | U04M09168 | 2004 | 200 | R-22 | |||
| Auxiliary Equipment - Water Treatment Services | ||||||||||
| Equipment Type | Original Equipment Manufacture | Pump # | Quantity # | Type / Horse Power | ||||||
| Pump | AURORA B4 - 1085389-1 / 411BF / 4X5X15 / 560 GPM / 185 FT. HD | |||||||||
| A.O. SMITH 50 HP / 230-460V / 1780 RPM / 326 T Frame | 1 | 1 | N/A | |||||||
| AURORA B4 - 1085389-2 / 411BF / 4X5X15 / 560 GPM / 185 FT. HD | ||||||||||
| A.O. SMITH 50 HP / 230-460V / 1780 RPM / 326 T Frame | 2 | 2 | N/A | |||||||
| Condenser H2O Pump | N/A | 2 | 2 | 15 | ||||||
| Chilled H2O Pumps | N/A | 2 | 2 | 40 |
| Site # | Equipment Location | HVAC - Chiller | ||||||||
| 18 | Concourse E PCA Plant V | |||||||||
| AOA | Chiller # | Original Equipment Manufacture | Equipment Type | Model # | Serial # | Year Installed | Tonnage | Refrigerant Types & Vintages | ||
| 1 | York | Screw | YSFCFASS5CPBS | YCCH233L0073YFZ | ||||||
| R | 1997 | 425 | R-22 | REMOVE FROM CONTRACT | ||||||
| 2 | York | Screw | YSFCFASS5CPBS | YCCH233L0230YFZ | ||||||
| R | 1997 | 425 | R-22 | |||||||
| 3 | York | Screw | YVAA0523 | 11551L98394194 | 2019 | 280 | R-134A | |||
| 4 | York | Screw | YVAA0523 | 11551L98394198 | 2019 | 280 | R-134A | |||
| Auxiliary Equipment - Water Treatment Services | ||||||||||
| Equipment Type | Original Equipment Manufacture | Pump # | Quantity # | Type / Horse Power | ||||||
| Pump | AURORA #95-07610-1 / 411 BF / 4X5X15 / 800 GPM / 174 FT. HD | |||||||||
| MARATHON 50 HP / 23--460 / 1770 RPM / 326 T Frame | 1 | 1 | N/A | |||||||
| AURORA #95-07610-2 / 411 BF / 4X5X15 / 800 GPM / 174 FT. HD | ||||||||||
| MARATHON 50 HP / 23--460 / 1770 RPM / 326 T Frame | 2 | 1 | N/A | |||||||
| Condenser H2O | N/A | 3 | 3 | 20 | ||||||
| Chilled H2O Pumps | N/A | 6 | 6 | 40 | ||||||
| Air Compressor | N/A | 1 | 1 | Duplex / 5 |
| Site # | Equipment Location | HVAC - Chiller | ||||||||
| 19 | Concourse H PCA Plant VI | |||||||||
| AOA | Chiller # | Original Equipment Manufacture | Equipment Type | Model # | Serial # | Year Installed | Tonnage | Refrigerant Types & Vintages | ||
| 1 | Trane | Screw | RTHC1D1F0H0D1L3E | U03C09229 | 2004 | 200 | R-134A | |||
| 2 | Trane | Screw | RTHC1D1F0H0D1L3E | U03C09227 | 2004 | 200 | R-134A | |||
| 3 | Trane | Screw | RTHC1D1F0H0D1L3E | U03C09228 | 2004 | 200 | R-134A | |||
| Auxiliary Equipment - Water Treatment Services | ||||||||||
| Equipment Type | Original Equipment Manufacture | Pump # | Quantity # | Type / Horse Power | ||||||
| Pump | AURORA 03-892406-1 / 421 BF / 3X4X14A / 430 GPM / 250 FT.HD. | |||||||||
| A.O. SMITH 50 HP / 230-460 / 1780 RPM / 326 T Frame | 1 | 1 | N/A | |||||||
| AURORA 3-892406-2 / 421 BF / 3X4X14A / 430 GPM / 250 FT.HD. | ||||||||||
| BALDOR 50 HP / 230-460 / 1775 RPM / 326 T Frame | 2 | 1 | N/A | |||||||
| Condenser H2O | N/A | 3 | 3 | 20 | ||||||
| Chilled H2O Pumps | N/A | 2 | 2 | 25 |
Zone 4
| ZONE 4 | ||||||||||
| Site # | Equipment Location | HVAC - Chiller | ||||||||
| 3 | Building 43/875 | Chiller # | Original Equipment Manufacture | Equipment Type | Model # | Serial # | Year Installed | Tonnage | Refrigerant Types & Vintages | |
| 1 | York | Centrifugal | YDHFY32V00 | 36Y51556204 | 2008 | 352 | R-134A | |||
| 2 | York | Centrifugal | YKERRQQ4-CJG | SLBM075910 | 2014 | 325 | R-123 | |||
| Auxiliary Equipment - Water Treatment Services | ||||||||||
| Equipment Type | Original Equipment Manufacture | Pump # | Quantity # | Type / Horse Power | ||||||
| Cooling Tower | Marley Stainless | 1 - 2 Cell | 2 | N/A | ||||||
| Condenser H2O Pump | N/A | 2 | 2 | 20 | ||||||
| Chilled H2O Pumps | N/A | 2 | 2 | 30 | ||||||
| Air Compressor | N/A | 1 | 1 | Duplex / 5 | ||||||
| Site # | Equipment Location | HVAC - Chiller | ||||||||
| 5 | Building 100/845 | Chiller # | Original Equipment Manufacture | Equipment Type | Model # | Serial # | Year Installed | Tonnage | Refrigerant Types & Vintages | |
| 1 | Trane | Centrifugal | CVHE500 | L04H04019 | 2004 | 450 | R-123 | |||
| 2 | Trane | Centrifugal | CVHE500 | L04H04025 | 2004 | 450 | R-123 | |||
| Auxiliary Equipment - Water Treatment Services | ||||||||||
| Equipment Type | Original Equipment Manufacture | Pump # | Quantity # | Type / Horse Power | ||||||
| Pump | Bell & Gossett e-HSC 12"/ C298853-01 / 175 PSI | |||||||||
| WEG 50 HP / 230-460 V / 1775 RPM / 324-6 T Frame | 1 | 1 | N/A | |||||||
| Bell & Gossett e-HSC 12"/ C298853-02 / 175 PSI | ||||||||||
| MARATHON 50 HP / 230-460 V / 1780 RPM / 326 T Frame | 2 | 1 | N/A | |||||||
| Cooling Tower | Evapco Stainless | 2 | 2 | N/A | ||||||
| Condenser H2O | N/A | 2 | 2 | 30 | ||||||
| Chilled H2O Pumps | N/A | 2 | 2 | 15 | ||||||
| Air Compressor | N/A | 1 | 1 | Duplex / 10 | ||||||
| Site # | Equipment Location | HVAC - Chiller | ||||||||
| 9 | Building 2208 / 721 | Chiller # | Original Equipment Manufacture | Equipment Type | Model # | Serial # | Year Installed | Tonnage | Refrigerant Types & Vintages | |
| 1 | Trane | CENTRVAC | CVHF485 | L18K04275 | 2019 | 500 | R-514 | |||
| 2 | Trane | CENTRVAC | CVHF485 | L18K04276 | 2019 | 500 | R-514 | |||
| Auxiliary Equipment - Water Treatment Services | ||||||||||
| Equipment Type | Original Equipment Manufacture | Pump # | Quantity # | Type / Horse Power | ||||||
| Pump | WEG 50 HP / 230-460 v / 1775 RPM / 324-6T Frame / ODP | |||||||||
| 1 | 1 | N/A | ||||||||
| WEG 50 HP / 230-460 v / 1775 RPM / 324-6T Frame / ODP | 2 | 1 | N/A | |||||||
| Cooling Tower | EVAPCO | 2 CELLS | 2 | N/A | ||||||
| Condenser H2O | N/A | 3 | 3 | 50 | ||||||
| Chilled H2O Pumps | N/A | 2 | 2 | 15 | ||||||
| Air Compressor | N/A | 1 | 1 | Duplex / 5 | ||||||
| Site # | Equipment Location | HVAC - Chiller | ||||||||
| 11 | Building 3090 | Chiller # | Original Equipment Manufacture | Equipment Type | Model # | Serial # | Year Installed | Tonnage | Refrigerant Types & Vintages | |
| 1 | York | YMC^2 | YMC2-S2708201 | SAGM-302390 | 2020 | 770 | R-134A | |||
| 2 | York | YMC^2 | YMC2-S2708201 | SAGM-302400 | 2020 | 770 | R-134A | |||
| Auxiliary Equipment - Water Treatment Services | ||||||||||
| Equipment Type | Original Equipment Manufacture | Pump # | Quantity # | Type / Horse Power | ||||||
| Cooling Tower | Evapco Stainless | 2 - 2 cell | 2 | N/A | ||||||
| Condenser H2O | N/A | 2 | 2 | 60 | ||||||
| Chilled H2O Pumps | N/A | 2 | 2 | 75 | ||||||
| Site # | Equipment Location | HVAC - Chiller | ||||||||
| 12 | Building 3099 CCPE | Chiller # | Original Equipment Manufacture | Equipment Type | Model # | Serial # | Year Installed | Tonnage | Refrigerant Types & Vintages | |
| 1 | York | Centrifugal | YKZ4Z4K7-DJGS | SLFM-243860 | 2019 | 2500 | R-134A | |||
| 2 | York | Centrifugal | YKZ4Z4K7-DJGS | SKCM-338150 | 2016 | 2500 | R-134A | |||
| 3 | York | Centrifugal | YKZ4Z4K7-DJGS | SLFM-244070 | 2019 | 2500 | R-134A | |||
| 4 | York | Centrifugal | YKJGJDJ4-DFES | GB1M-171807 | 2003 | 1800 | R-134A | |||
| 5 | York | Centrifugal | YKJGJDJ4-DFES | GB1M-171808 | 2003 | 1800 | R-134A | |||
| 6 | York | Centrifugal | OM 4000 | GHL0252801 | 2005 | 4000 | R-134A | |||
| 7 | York | Centrifugal | OM 4000 | GFL0112796 | 2005 | 4000 | R-134A | |||
| 8 | York | Centrifugal | OM 4000 | GKL0162805 | 2005 | 4000 | R-134A | |||
| 9 | York | Centrifugal | OM 4000 | GMP023869 | 2005 | 4000 | R-134A | |||
| 10 | York | Centrifugal | YS FB FA S5-CT ES | SBMM-877970 | 2005 | 500 | R-22 | |||
| 11 | York | Centrifugal | YS FB FA S5-CT ES | SBMM-877820 | 2005 | 500 | R-22 |
| Auxiliary Equipment - Water Treatment Services | ||||
| Equipment Type | Original Equipment Manufacture | Pump # | Quantity # | Type / Horse Power |
| Pump | AURORA 06-1343440 / 411-BF / 10X12X15B / 4000 GPM / 130 FT. HD. LINCOLN 200 HP / 460 V / 1780 RPM / 445-TS | 1 | 1 | N/A |
| AURORA 88-12874-2 / 411-BF / 10X12X15B / 4000 GPM / 130 FT.HD. LINCOLN 200 HP / 460 V / 1780 RPM / 445-TS | 2 | 1 | N/A | |
| AURORA 88-12874-4 / 411-BF / 10X12X15B / 4000 GPM / 130 FT.HD. LINCOLN 200 HP / 460 V / 1780 RPM / 445-TS | 3 | 1 | N/A | |
| AURORA 88-12874-4 / 411-BF / 10X12X15B / 4000 GPM / 130 FT.HD. LINCOLN 200 HP / 460 V / 1780 RPM / 445-TS | 4 | 1 | N/A | |
| PEERLESS 200 HP / 460 V / 1780 RPM / 445-TS US MOTOR 200 HP / 460 V / 1785 RPM / 445-T | 5 | 1 | N/A | |
| PEERLESS 200 HP / 460 V / 1780 RPM / 445-TS US MOTOR 200 HP / 460 V / 1785 RPM / 445-T | 6 | 1 | N/A | |
| PEERLESS 200 HP / 460 V / 1780 RPM / 445-TS US MOTOR 200 HP / 460 V / 1785 RPM / 445-T | 7 | 1 | N/A | |
| PEERLESS 200 HP / 460 V / 1780 RPM / 445-TS US MOTOR 200 HP / 460 V / 1785 RPM / 445-T | 8 | 1 | N/A | |
| PEERLESS 200 HP / 460 V / 1780 RPM / 445-TS US MOTOR 200 HP / 460 V / 1785 RPM / 445-T | 9 | 1 | N/A | |
| PEERLESS 200 HP / 460 V / 1780 RPM / 445-TS US MOTOR 200 HP / 460 V / 1785 RPM / 445-T | 10 | 1 | N/A | |
| PEERLESS 200 HP / 460 V / 1780 RPM / 445-TS US MOTOR 200 HP / 460 V / 1785 RPM / 445-T | 11 | 1 | N/A | |
| PEERLESS 200 HP / 460 V / 1780 RPM / 445-TS US MOTOR 200 HP / 460 V / 1785 RPM / 445-T | 12 | 1 | N/A | |
| PEERLESS 200 HP / 460 V / 1780 RPM / 445-TS US MOTOR 200 HP / 460 V / 1785 RPM / 445-T | 13 | 1 | N/A | |
| Cooling Tower | Marley | 1 - 8 Cell | 8 | N/A |
| Condenser H2O | N/A | 6 | 6 | 500 |
| N/A | 3 | 3 | 300 | |
| Chilled H2O Pumps | N/A | 4 | 4 | 125 |
| N/A | 7 | 7 | 100 | |
| N/A | 2 | 2 | 50 | |
| Air Compressor | N/A | 2 | Duplex / 10 | |
| Inventory pumps | WEG 2HP 3450RPM | 2 | 2 | 2 |
| Motor Cooling Pumps | N/A | 9 | 9 | 4 - 7 1/2 HP |
3 - 2 1/2 HP
2 - 1 HP
Zone 5
| ZONE 5 | ||||||||||
| Site # | Equipment Location | HVAC - Chiller | ||||||||
| 7 | Building 720 | |||||||||
| AOA | Chiller # | Original Equipment Manufacture | Equipment Type | Model # | Serial # | Year Installed | Tonnage | Refrigerant Types & Vintages | ||
| 1 | Trane | Centrifugal | CVHE-320 | L18G03205 | 2019 | 250 | R-514A | |||
| 2 | Trane | Centrifugal | CVHE-320 | L18G03207 | 2019 | 250 | R-514A | |||
| 3 | Trane | Centrifugal | CVHE-320 | L18G03206 | 2019 | 250 | R-514A | |||
| Auxiliary Equipment - Water Treatment Services | ||||||||||
| Equipment Type | Original Equipment Manufacture | Pump # | Quantity # | Type / Horse Power | ||||||
| Pump | AURORA 20-2582361-1 / 411 / 5X6X11G / 750 GPM / 75 FT.HD. WEG 20 HP / 230-460 V / 1765 RPM / 254-6T Frame / TEFC | 1 | 1 | N/A | ||||||
| AURORA 20-2582361-2 / 411 / 5X6X11G / 750 GPM / 75 FT.HD. WEG 20 HP / 230-460 V / 1765 RPM / 254-6T Frame / TEFC | 2 | 1 | N/A | |||||||
| Cooling Tower | Evapco | 3 | 3 | N/A | ||||||
| Condenser H2O Pump | N/A | 3 | 3 | 10 | ||||||
| Chilled H2O Pump | N/A | 3 | 3 | 5 | ||||||
| Site # | Equipment Location | HVAC - Chiller | ||||||||
| 8 | Building 815 | Chiller # | Original Equipment Manufacture | Equipment Type | Model # | Serial # | Year Installed | Tonnage | Refrigerant Types & Vintages | |
| 1 | York | Screw | YR VD VD to 46 A | SKLM-783320 | 2005 | 250 | R-134A | |||
| 2 | York | Screw | YR VD VD to 46 A | SKLM-783460 | 2005 | 250 | R-134A | |||
| Auxiliary Equipment - Water Treatment Services | ||||||||||
| Equipment Type | Original Equipment Manufacture | Pump # | Quantity # | Type / Horse Power | ||||||
| Cooling Tower | Marley Stainless | 1 - 2 Cell | 2 | N/A | ||||||
| Condenser H2O Pump | N/A | 2 | 2 | 20 | ||||||
| Chilled H2O Pump | N/A | 2 | 2 | 30 | ||||||
| Site # | Equipment Location | HVAC - Chiller | ||||||||
| 13 | Concourse G | |||||||||
| AOA | Chiller # | Original Equipment Manufacture | Equipment Type | Model # | Serial # | Year Installed | Tonnage | Refrigerant Types & Vintages | ||
| 1 | York | MaxE Centrifugal | YK4G4SQ7-EPHS | SAHM-475770 | 2020 | 500 | R-134A | |||
| 2 | Trane | Centrifugal | CVHF570 | L16E02609 | 2016 | 500 | R-123 | |||
| Auxiliary Equipment - Water Treatment Services | ||||||||||
| Equipment Type | Original Equipment Manufacture | Pump # | Quantity # | Type / Horse Power | ||||||
| PUMP G-5 | BALDOR 15 HP / 230-460 V / 1760 RPM / 284U Frame | 1 | 1 | N/A | ||||||
| Cooling Tower | Evapco Stainless | 1 | 1 | N/A | ||||||
| Condenser H2O Pump | N/A | 2 | 2 | 30 | ||||||
| Chilled H2O Pump | N/A | 3 | 3 | 15 | ||||||
| Air Compressor | N/A | 1 | 1 | Simplex / 0.5 | ||||||
| N/A | 1 | 1 | Simplx / 5 | |||||||
| 28 | Miami-Opa Locka | Chiller # | Original Equipment Manufacture | Equipment Type | Model # | Serial # | Year Installed | Tonnage | Refrigerant Types & Vintages | |
| 1 | Trane Air Cooled | Screw | CGAM 110F | 410E15819 | 2012 | 110 | R-134A | |||
| Auxiliary Equipment - Water Treatment Services | ||||||||||
| Equipment Type | Original Equipment Manufacture | Pump # | Quantity # | Type / Horse Power | ||||||
| Chilled H2O Pump | N/A | 4 | 4 | 2 | ||||||
| 30 | 7200 NW 19th Street | Chiller # | Original Equipment Manufacture | Equipment Type | Model # | Serial # | Year Installed | Tonnage | Refrigerant Types & Vintages | |
| 1 | TRANE | C-VAC | CHE032FA3A)3UE | L99HO3288M | N/A | 320 | 134A | |||
| 2 | TRANE | C-VAC | RTHDUB2FXHOUA | UO7B01909 | N/A | 320 | 22 | |||
| Auxiliary Equipment - Water Treatment Services | ||||||||||
| Equipment Type | Original Equipment Manufacture | Pump # | Quantity # | Type / Horse Power | ||||||
| Cooling Tower | Marley | 1 | 1 | N/A | ||||||
| Marley | 2 | 1 | N/A | |||||||
| Condenser H2O Pump | N/A | 1 | 1 | N/A | ||||||
| N/A | 2 | 1 | N/A | |||||||
| Chilled H2O Pump | N/A | 1 | 1 | N/A | ||||||
| N/A | 2 | 1 | N/A | |||||||
| Air Compressor | N/A | 2 | 1 | N/A |