REISSUED STRUCTURAL SET DRAWINGS (REVISED ADD. 1).pdf
PDF 2 MB Posted
- Solicitation number
- 15095
- Issued by
- York County, Winchester City, Virginia
About this file
This document contains the reissued structural set drawings and general notes for the Water Street Restaurant Renovations project in Yorktown, Virginia. The project involves the renovation of two existing restaurants into a single restaurant, as outlined in the Contract Documents. The project is being procured by York County, Virginia through IFB No. B6542-EY.
The structural drawings provide details on the design criteria, foundation notes, cast-in-place concrete notes, concrete masonry notes, structural steel notes, and prefabricated metal-plate-connected wood truss notes for the project. The drawings specify the required live loads, snow loads, wind loads, and seismic loads, as well as the materials, construction, and inspection requirements for the structural elements. Contractors will need to coordinate the structural work with the architectural, civil, mechanical, plumbing, and electrical drawings and specifications.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
IIRISK CATEGORY
CLASSIFICATION OF BUILDING
SUPER IMPOSED ROOF DEAD LOADS - UNIFORM:
2 PSFSHEATHING
2 PSFCEILING
3 PSFROOFING
3 PSFDUCTS, LIGHTS, MISC. MECHANICAL
LIVE LOADS - UNIFORM:
100 PSFSLAB ON GRADE
20 PSFROOF
150 PSFMECHANICAL PLATFORM
300#ROOFS
300#GRATINGS
LIVE LOADS - CONCENTRATED:
15 PSFGROUND SNOW LOAD
15 PSFSLOPED ROOF LOAD
1.0THERMAL FACTOR (Ct) 1.0IMPORTANCE FACTOR (Is)
SNOW LOADS:
1.0EXPOSURE FACTOR (Ce)
115 MPHULTIMATE DESIGN WIND SPEED (VULT)
89 MPHNOMINAL DESIGN (VASD)[BASIC] WIND SPEED
±0.18INTERNAL PRESSURE COEFFICIENT
DEXPOSURE CATEGORY
WIND LOADS:
COMPONENT AND CLADDING PRESSURES:
58 PSFWALLS, ZONE 5 (10 SF)
90 PSFROOF, ZONE 3 (10 SF)
148 PSFPARAPET, END/CORNER (10 SF)
ULTIMATE WIND BASE SHEARS (FOR MWFRS):
11 KIPSVx 7 KIPSVy
COVERED OUTDOOR ENTRY:
DSITE CLASSIFICATION
ASEISMIC DESIGN CATEGORY
1.0IMPORTANCE FACTOR (IE)
SEISMIC LOADS:
SPECTRAL RESPONSE ACCELERATIONS:
0.103S 0.041S 0.165S 0.100S 0.110S 0.066S
EQUIVALENT LATERAL FORCEANALYSIS PROCEDURE
STEEL SYSTEMS NOT
SPECIFICALLY DETAILED FOR
SEISMIC RESISTANCE
LATERAL FORCE RESISTING SYSTEM
3.0RESPONSE MODIFICATION COEFFICIENT (R)
0.01SEISMIC RESPONSE COEFFICIENT (Cs)
2 KIPSULTIMATE SEISMIC BASE SHEAR (V)
WINDCONTROLLING LATERAL LOADS
LATERAL DESIGN CONTROL
1. THE STRUCTURAL DRAWINGS MUST BE USED IN CONJUNCTION WITH THE
ARCHITECTURAL, CIVIL, MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS,
AND THE SPECIFICATIONS. THE CONTRACTOR MUST VERIFY THE REQUIREMENTS
OF OTHER TRADES AS TO SLEEVES, CHASES, HANGERS, INSERTS, ANCHORS,
HOLES, AND ADDITIONAL ITEMS TO BE PLACED OR SET IN THE STRUCTURAL
WORK.
2. THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE WITH THE PROVISIONS
OF THE VIRGINIA CONSTRUCTION CODE, 2018 EDITION.
3. THE WORK OUTLINED IN SPECIFICATION SECTION 014100 IS SUBJECT TO SPECIAL
INSPECTIONS AS DESCRIBED IN THE TECHNICAL SPECIFICATIONS.
4. THE CONTRACTOR MUST PROVIDE TEMPORARY SHORING AND BRACING
REQUIRED TO ERECT AND HOLD THE STRUCTURE IN PROPER ALIGNMENT UNTIL
PERMANENT SUPPORTS AND LATERAL BRACING ARE IN PLACE.
5. PORTIONS OF THE STRUCTURE NOT ALTERED AND NOT AFFECTED BY THE
ALTERATION HAVE NOT BEEN REVIEWED FOR COMPLIANCE WITH THE CODE
REQUIREMENTS FOR A NEW STRUCTURE.
6. BEFORE PROCEEDING WITH WORK WITHIN THE EXISTING STRUCTURE, THE
CONTRACTOR MUST BECOME FAMILIAR WITH THE EXISTING STRUCTURAL
CONDITIONS. ANY SHORING OR BRACING SHOWN IS A PARTIAL AND SCHEMATIC
REPRESENTATION OF THAT REQUIRED. THE CONTRACTOR MUST BE SOLELY
RESPONSIBLE FOR THE DESIGN AND ERECTION OF ANY AND ALL SAFEGUARDS
NECESSARY TO PROTECT THE EXISTING STRUCTURE. THE CONTRACTOR MUST
PROVIDE SHORING, BRACING, AND OTHER SAFEGUARDS TO MAINTAIN ALL PARTS
OF THE STRUCTURE IN A SAFE CONDITION AT ALL TIMES DURING THE PROCESS
OF DEMOLITION AND CONSTRUCTION.
7. THE CONTRACTOR MUST FIELD VERIFY THE DIMENSIONS, ELEVATIONS, AND
OTHER REQUIREMENTS NECESSARY FOR THE PROPER CONSTRUCTION AND
ALIGNMENT OF THE NEW PORTIONS OF THE STRUCTURE TO THE EXISTING. ANY
DIMENSIONS SHOWN OF EXISTING STRUCTURES MUST BE CONSIDERED AS
APPROXIMATE AND ADEQUATE FOR BIDDING PURPOSES ONLY. THE
CONTRACTOR MUST MAKE ALL MEASUREMENTS NECESSARY FOR THE
FABRICATION AND ERECTION OF STRUCTURAL MEMBERS. DISCREPANCIES
MUST BE BROUGHT TO THE ATTENTION OF THE ARCHITECT.
8. DISCREPANCIES BETWEEN DRAWINGS, BETWEEN THE DRAWINGS AND THE
SPECIFICATIONS, OR WITHIN THE SPECIFICATIONS, MUST BE BROUGHT TO THE
ATTENTION OF THE ARCHITECT AND ENGINEER DURING THE BIDDING PROCESS
IN TIME TO PERMIT CLARIFICATION BY ADDENDUM. IF INCONSISTENCIES,
DISCREPANCIES OR CONTRADICTIONS IN THE CONTRACT DOCUMENTS ARE
DISCOVERED AFTER THE CLOSE OF BIDDING QUESTIONS, THE CONTRACTOR
MUST BE DEEMED BY SUBMITTAL OF HIS BID, TO HAVE BID THE MOST COSTLY AS
TO LABOR, MATERIALS, DURATION, SEQUENCE AND METHOD OF CONSTRUCTION
TO PROVIDE THE WORK.
9. PRIOR TO ISSUING THE STRUCTURAL DRAWINGS FOR ANY PURPOSE,
AUTHORIZATION MUST BE OBTAINED FROM THE STRUCTURAL ENGINEER OF
RECORD. WHEN AUTHORIZED, THE DOCUMENTS THAT ARE RELEASED MUST BE
CLEARLY IDENTIFIED WITH THE AUTHORIZED PURPOSE AND MUST INCLUDE THE
DATE OF RELEASE.
10. THESE STRUCTURAL DRAWINGS WERE PREPARED BASED, IN PART, ON
INFORMATION CONTAINED IN STRUCTURAL DRAWINGS PREPARED BY SPEIGHT
MARSHALL & FRANCIS LABELED 'RIVERWALK LANDING AT YORKTOWN
YORKTOWN COUNTY, VIRGINIA' DATED 09-29-03.
11. DESIGN CRITERIA:
GENERAL NOTES:
LIVE LOAD REDUCTION OF THE UNIFORMLY DISTRIBUTED FLOOR LIVE
LOADS HAS BEEN UTILIZED.
UNLESS OTHERWISE NOTED, CONCENTRATED LOADS ARE APPLIED
UNIFORMLY OVER 2'-6" x 2'-6" AREA.
S 1
MS M1
DS D1
1. FOUNDATIONS HAVE BEEN DESIGNED FOR A NET ALLOWABLE SOIL BEARING
PRESSURE OF 2000 PSF PER EXISTING STRUCTURAL DRAWINGS.
2. PRIOR TO PLACING FOUNDATION CONCRETE, ALL FOUNDATION EXCAVATIONS
MUST BE INSPECTED BY THE OWNER'S GEOTECHNICAL TESTING AGENCY
SPECIAL INSPECTOR TO EXPLORE THE EXTENT OF LOOSE, SOFT, EXPANSIVE, OR
OTHERWISE UNSATISFACTORY SOIL MATERIAL AND TO VERIFY DESIGN BEARING
PRESSURE. DIRECTION FOR CORRECTIVE ACTION WILL BE PROVIDED BY THE
OWNER'S GEOTECHNICAL TESTING AGENCY SPECIAL INSPECTOR WHERE
UNSATISFACTORY SOILS ARE PRESENT.
3. NO UNBALANCED BACKFILLING MUST BE DONE AGAINST MASONRY OR
CONCRETE WALLS UNLESS WALLS ARE SECURELY BRACED AGAINST
OVERTURNING, EITHER BY TEMPORARY CONSTRUCTION BRACING OR BY
PERMANENT CONSTRUCTION.
4. CONTROL GROUNDWATER AND SURFACE RUNOFF THROUGHOUT THE
CONSTRUCTION PROCESS. INUNDATION AND LONG TERM EXPOSURE OF
BEARING SURFACES WHICH RESULT IN DETERIORATION OF BEARING MUST BE
PREVENTED.
FOUNDATION NOTES:
1. CONCRETE MUST BE IN ACCORDANCE WITH AMERICAN CONCRETE INSTITUTE
(ACI) 301 AND 318.
2. CONCRETE MUST BE NORMAL WEIGHT AND MUST OBTAIN 28 DAY COMPRESSIVE
STRENGTHS AS FOLLOWS:
A. SLAB-ON-GRADE ............................................................ 3,500 PSI
B. CONCRETE NOT OTHERWISE NOTED.......................... 3,000 PSI
3. REINFORCING MATERIALS MUST BE AS FOLLOWS:
A. REINFORCING BARS - ASTM A615, GRADE 60, DEFORMED.
B. WELDED REINFORCING BARS - ASTM A706, GRADE 60.
C. WELDED WIRE REINFORCEMENT - ASTM A1064, WELDED STEEL WIRE
REINFORCEMENT; PROVIDE SHEET TYPE, ROLL TYPE IS NOT ACCEPTABLE.
4. ALL REINFORCING STEEL AND EMBEDDED ITEMS SUCH AS ANCHOR RODS AND
WELD PLATES MUST BE ACCURATELY PLACED AND ADEQUATELY TIED AND
SUPPORTED BEFORE CONCRETE IS PLACED TO PREVENT DISPLACEMENT
BEYOND PERMITTED TOLERANCES.
5. CONCRETE COVER TO REINFORCING STEEL MUST CONFORM TO THE MINIMUM
COVER RECOMMENDATIONS IN ACI 318, UNLESS THE DRAWINGS SHOW GREATER
COVER REQUIREMENTS.
6. LAP CONTINUOUS REINFORCING STEEL 57 X BAR DIAMETER, TYPICAL UNLESS
OTHERWISE NOTED.
CAST-IN-PLACE CONCRETE NOTES:
1. CONCRETE MASONRY MATERIALS AND CONSTRUCTION MUST CONFORM TO THE
AMERICAN CONCRETE INSTITUTE (ACI) 530.
2. CONCRETE MASONRY UNITS MUST CONFORM TO ASTM C90 AND MUST BE MADE
WITH NORMAL WEIGHT AGGREGATE. MINIMUM NET AREA COMPRESSIVE
STRENGTH OF MASONRY UNITS MUST BE 2,000 PSI AT 28 DAYS.
3. COMPRESSIVE STRENGTH OF MASONRY MUST BE DETERMINED BY THE UNIT
STRENGTH METHOD AS SET FORTH IN ACI 530.1. THE NET AREA COMPRESSIVE
STRENGTH OF MASONRY, f'm, MUST BE 2,000 PSI AT 28 DAYS.
4. MORTAR MUST BE TYPE 'M' OR 'S' AND MUST COMPLY WITH ASTM C270,
PROPORTIONS OR PROPERTIES SPECIFICATION.
5. GROUT MUST COMPLY WITH EITHER THE PROPORTIONS OR PROPERTIES
SPECIFICATION OF ASTM C476 AND THIS MIX MUST BE PROPORTIONED TO
OBTAIN A DOCUMENTED 28 DAY COMPRESSIVE STRENGTH OF 2,000 PSI, WITH AN
8-11 INCH SLUMP WHEN PLACED IN THE CONCRETE MASONRY UNITS.
6. REINFORCING STEEL MUST COMPLY WITH ASTM A615, GRADE 60. SHOP
FABRICATE REINFORCING BARS WHICH ARE SHOWN TO BE BENT OR HOOKED.
7. ALL BOND BEAMS, REINFORCED CELLS AND CELLS WITH EXPANSION BOLTS,
EMBED PLATES OR OTHER ANCHORS AND ALL CELLS BELOW GRADE MUST BE
GROUTED SOLID. GROUT PROCEDURE MUST COMPLY WITH ACI 530.1.
8. ALL CMU WALLS MUST BE REINFORCED CONTINUOUSLY FROM FOUNDATION TO
TOP OF WALL. WHERE REINFORCING IS INTERRUPTED, OFFSET AND LAP
ADDITIONAL BARS PER THE “TYPICAL OFFSET SPLICE AT MASONRY WALL
DETAILS.”
9. LAP ALL REINFORCING AS FOLLOWS UNLESS OTHERWISE NOTED:
10. PROVIDE MECHANICAL SPLICES FOR ALL BARS AT CONTRACTOR'S OPTION.
11. ALL NON-BEARING MASONRY WALLS MUST BE REINFORCED WITH #4 VERTICAL
BARS AT 40 INCHES ON CENTER, TYPICAL UNLESS OTHERWISE NOTED.
12. PROVIDE REINFORCING STEEL DOWELS OF THE SAME SIZE AND SPACING AS
VERTICAL REINFORCING FROM THE SUPPORTING STRUCTURE. DOWELS MUST
HAVE STANDARD ACI HOOKS.
13. PROVIDE STANDARD 9 GAGE TRUSS TYPE HORIZONTAL JOINT REINFORCING IN
CMU WALLS AT 16 INCHES ON CENTER AND IN TWO JOINTS IMMEDIATELY ABOVE
AND BELOW ALL OPENINGS, EXTENDING A MINIMUM OF 2 FEET BEYOND THE
JAMB ON EACH SIDE OF THE OPENING, EXCEPT AT CONTROL JOINTS.
#4
#5
BAR SIZE
12"
20"
8" CMU
12"
16"
10" CMU
12"
12"
12" CMU
CONCRETE MASONRY NOTES:
NOTES:
1. ASSUMES 2" CLEAR MASONRY COVER.
REINFORCING CENTERED
1. STRUCTURAL STEEL MUST BE IN ACCORDANCE WITH THE AMERICAN INSTITUTE
OF STEEL CONSTRUCTION (AISC) 360.
2. STRUCTURAL STEEL MUST COMPLY WITH THE FOLLOWING SPECIFICATIONS:
A. STRUCTURAL STEEL SHAPES, PLATES AND BARS UNLESS OTHERWISE
NOTED - ASTM A36, Fy = 36 KSI B. STRUCTURAL STEEL W-SHAPES - ASTM A992, Fy = 50 KSI
C. HOLLOW STRUCTURAL SECTIONS (HSS):
a. SQUARE AND RECTANGULAR - ASTM A500, GRADE C, Fy = 50 KSI
b. ROUND - ASTM A500, GRADE C, Fy = 46 KSI
D. ANCHOR RODS - ASTM F1554, GRADE 36
E. HIGH STRENGTH BOLTS - ASTM A325 (TYPICAL UON)
F. WASHERS - ASTM F436
G. NUTS - ASTM A563
3. UNLESS OTHERWISE NOTED, ALL REQUIRED DESIGN STRENGTHS AND
REACTIONS INDICATED ARE BASED ON THE "LOADING COMBINATIONS USING
STRENGTH DESIGN OR LOAD AND RESISTANCE FACTOR DESIGN" PER SECTION
1605.2 OF THE BUILDING CODE.
4. UNLESS OTHERWISE NOTED, BEAM CONNECTIONS MUST BE AISC "SIMPLE
SHEAR CONNECTIONS" WITH ASTM A325 BOLTS. DESIGN CONNECTIONS FOR THE
REACTIONS (LRFD FACTORED LOADING) SHOWN ON THE DRAWINGS AND THE
MINIMUM NUMBER OF BOLTS SHOWN BELOW. IF NO REACTION IS SHOWN,
DESIGN CONNECTIONS FOR REACTIONS AND THE MINIMUM NUMBER OF BOLTS
SHOWN BELOW.
5. REFER TO THE SPECIFICATIONS FOR REQUIREMENTS OF "DELEGATED DESIGN"
CONNECTIONS.
6. FOR STRUCTURAL STEEL CONNECTIONS INDICATED AS "DELEGATED DESIGN",
INCLUDE STRUCTURAL CALCULATIONS SIGNED AND SEALED BY THE QUALIFIED
PROFESSIONAL ENGINEER REGISTERED IN THE RESPONSIBLE FOR THEIR
PREPARATION. IN ADDITION, THE PROFESSIONAL ENGINEER RESPONSIBLE FOR
CONNECTION DESIGN MUST REVIEW THE SHOP DRAWINGS PRIOR TO SUBMITTAL
TO VERIFY THAT THE CONNECTIONS AS DETAILED ON THE SHOP DRAWINGS
COMPLY WITH THE CONNECTION DESIGN REQUIREMENTS OF THE FINAL
CALCULATIONS. A REVIEW LETTER, SIGNED AND SEALED BY THE PROFESSIONAL
ENGINEER RESPONSIBLE FOR CONNECTION DESIGN MUST BE PROVIDED WITH
THE SHOP DRAWINGS AND CALCULATION SUBMITTAL STATING THAT THIS
REVIEW AND VERIFICATION HAS BEEN COMPLETED.
7. DELEGATED DESIGN CONNECTIONS ARE AS FOLLOWS:
A. MOMENT FRAMES
8. WELDING MUST BE IN ACCORDANCE WITH AWS D1.1, "STRUCTURAL WELDING
CODE - STEEL." WELD ELECTRODES MUST BE E70XX LOW HYDROGEN. UNLESS
OTHERWISE NOTED, PROVIDE CONTINUOUS FILLET WELDS WITH MINIMUM SIZE
REQUIRED BY TABLE J2.4 AISC 360.
9. STRUCTURAL STEEL SCHEDULED TO RECEIVE SPRAYED-ON FIREPROOFING
MUST NOT BE PRIME PAINTED.
10. HOT-DIP GALVANIZE AFTER FABRICATION THE FOLLOWING:
A. ANGLES AND PLATES SUPPORTING MASONRY IN EXTERIOR WALLS.
B. LINTELS AND LINTEL ASSEMBLIES SUPPORTING MASONRY IN EXTERIOR
WALLS.
C. ALL STEEL EXPOSED TO WEATHER IN THE FINAL CONSTRUCTION.
D. ITEMS IDENTIFIED AS GALVANIZED ON ARCHITECTURAL OR STRUCTURAL
DRAWINGS.
11. STEEL MEMBERS MUST BE SPLICED ONLY WHERE INDICATED OR APPROVED.
STRUCTURAL STEEL NOTES:
W8
W12 AND W14
W10
BEAM SIZE
25 KIPS
DESIGN
REACTION (LRFD)
MIN # OF BOLTS
25 KIPS
43 KIPS
C O M M O
N W
EA
LTH OF
V I
R G I N I A
P R O F
E
SS IONAL EN
G
IN
E E R
Structural Engineers 1519 Summit Ave., Suite 101
Richmond, VA 23230
804.346.3935 - lynchmykins.com
All ideas, designs, arrangements and plans indicated or represented by this drawing are property of ENTEROS DESIGN, PC; created, evolved and developed for the sole use of this project. These ideas, design arrangements and/or plans shall not be used by or disclosed to any person, firm or corporation for any purpose without written permission from ENTEROS DESIGN, PC. Written dimensions on these drawings shall have precedence over scaled dimensions. Contractors shall verify and be responsible for all dimensions and conditions on the job. The Architect must be notified of any variations from the dimensions and conditions shown on these drawings.
© 2022 ENTEROS DESIGN, PC
7 NORTH 25TH STREET
RICHMOND, VA 23223
804.861.1200 P
4/14/23
W A
TE
R
S
TR
EE
T
R E
ST
A U
R A
N T
Y O
R K
TO
W
N V
IR
G
IN
IA
S0.01
PROJ. NO.: 211005
DATE: 04/14/23
DRAWN BY: BRW
GENERAL NOTES
CONSTRUCTION
DOCUMENTS
Lic. No. 017580
JOHN H. HANCOCK
REVISIONS
# DATE DESCRIPTION
1 05/09/2023 ADDENDUM 1
1. ROUGH CARPENTRY MUST BE IN ACCORDANCE WITH THE AMERICAN WOOD
COUNCIL (AWC) "NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION."
2. UNLESS OTHERWISE NOTED, USE 'COMMON' NAILS AND ALL NAILING MUST
CONFORM TO THE "FASTENING SCHEDULE" TABLE 2304.10.1 OF THE BUILDING
CODE.
3. WOOD FRAMING MEMBERS MUST COMPLY WITH PS 20 "AMERICAN SOFTWOOD
LUMBER STANDARD" AND THE FOLLOWING REQUIREMENTS:
A. MOISTURE CONTENT - SEASONED, WITH 19 PERCENT MAXIMUM MOISTURE
CONTENT.
B. GRADE - NO. 2, OR BETTER UNLESS OTHERWISE NOTED.
C. SPECIES - SPRUCE-PINE-FUR UNDER NLGA RULES.
4. WOOD STRUCTURAL PANELS (WSP) MUST COMPLY WITH PS 1 "U.S. PRODUCT
STANDARD FOR CONSTRUCTION AND INDUSTRIAL PLYWOOD" FOR PLYWOOD
CONSTRUCTION PANELS AND THE FOLLOWING REQUIREMENTS:
A. EXTERIOR WALL AND SHEAR WALL SHEATHING: 7/16" INCH, APA RATED
SHEATHING, EXTERIOR EXPOSURE DURABILITY CLASSIFICATION.
B. ROOF SHEATHING: 9/16" INCH, APA RATED SHEATHING, EXTERIOR
EXPOSURE DURABILITY CLASSIFICATION. PROVIDE TONGUE-AND-GROOVE
EDGES OR USE "PLY-CLIPS" AT MID-SPAN BETWEEN EACH SUPPORT.
5. ALL WOOD FRAMING MEMBERS PERMANENTLY EXPOSED TO THE WEATHER AND
ALL SILL PLATES IN CONTACT WITH CONCRETE MUST BE PRESERVATIVE-
TREATED. REFER TO THE SPECIFICATIONS.
6. METAL FRAMING ANCHORS, HOLD DOWNS, HURRICANE TIES, HANGERS, ETC.
MUST COMPLY WITH ASTM A653 AND BE CAPABLE OF SUPPORTING THE
REACTIONS SHOWN. WHERE PRODUCTS OF A SPECIFIC MANUFACTURER ARE
SHOWN, EQUAL PRODUCTS OF ANOTHER MANUFACTURER MAY BE USED IF
APPROVED.
7. UNLESS OTHERWISE NOTED, ATTACH BLOCKING AND NAILERS TO STEEL
FRAMING USING 3/16 INCH DIAMETER POWDER ACTUATED FASTENERS AT 24
INCHES ON CENTER OR 1/2 INCH DIAMETER BOLTS AT 48 INCHES ON CENTER.
STAGGER FASTENERS TO ALTERNATE SIDES OF BEAM WEB.
8. WHERE MULTIPLE FRAMING MEMBERS ARE INDICATED, SCAB CONTINGENT
MEMBERS TOGETHER WITH 16d NAILS AT 12 INCHES ON CENTER, ALTERNATING
AT 2 INCHES FROM EACH EDGE.
9. ALL CONNECTION HARDWARE IN CONTACT WITH PRESERVATIVE TREATED
WOOD MUST BE HOT-DIP GALVANIZED COATED.
10. POWDER ACTUATED FASTENERS (PAF) MUST HAVE A MINIMUM ALLOWABLE
CAPACITY INTO THE BASE MATERIAL AS FOLLOWS UNLESS OTHERWISE NOTED:
A. STEEL: SHEAR = 600 LBS
TENSION = 250 LBS
B. CONCRETE: SHEAR = 260 LBS
TENSION = 255 LBS
ROUGH CARPENTRY NOTES:
1. PREFABRICATED METAL-PLATE-CONNECTED WOOD TRUSSES MUST BE IN
ACCORDANCE WITH THE AMERICAN FOREST AND PAPER ASSOCIATION (AF&PA)
"NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION" AND THE TRUSS
PLATE INSTITUTE (TPI) "NATIONAL DESIGN STANDARDS FOR METAL-PLATE-
CONNECTED WOOD TRUSS CONSTRUCTION".
2. SUBMIT SHOP DRAWINGS SIGNED AND SEALED BY A VIRGINIA LICENSED
PROFESSIONAL ENGINEER RESPONSIBLE FOR THE DESIGN OF PREFABRICATED
METAL-PLATE-CONNECTED WOOD TRUSSES. SHOP DRAWINGS MUST INCLUDE
DESIGN LOADINGS AND REACTIONS APPLIED TO THE SUPPORTING STRUCTURE.
INCLUDE ALL TRUSS SPLICE DETAILS AND TRUSS-TO-TRUSS CONNECTION
DETAILS. SECONDARY BENDING STRESSES IN TRUSS TOP AND BOTTOM CHORDS
DUE TO MEMBER LOADS MUST BE CONSIDERED IN THE DESIGN.
3. WOOD TRUSS FRAMING MEMBERS MUST COMPLY WITH PS 20 "AMERICAN
SOFTWOOD LUMBER STANDARD" AND MUST BE SIZED BY THE MANUFACTURER
FOR THE LOADS INDICATED.
4. METAL CONNECTOR PLATES MUST COMPLY WITH ASTM A446, GRADE A WITH
COATING AS SPECIFIED.
5. WOOD TRUSS DESIGN LOADS MUST BE AS INDICATED IN "GENERAL NOTES" AND
AS FOLLOWS:
A. TOP CHORD DEAD LOAD: 10 PSF (PLUS ADDITIONAL 5 PSF AT
SUPERIMPOSED ROOF FRAMING AREAS).
B. WIND LOAD: WHEN CALCULATING NET UPLIFT REACTIONS, USE MAXIMUM
RESISTING DEAD LOAD = 7 PSF ON TOP CHORD AND 0 PSF ON BOTTOM
CHORD.
C. BOTTOM CHORD DEAD LOAD: 5 PSF.
6. WHERE MULTIPLE TRUSSES ARE INDICATED, SCAB CONTINGENT TRUSS
MEMBERS TOGETHER WITH 16d NAILS AT 12 INCHES ON CENTER.
7. IN ADDITION TO THE TRUSS BRACING SHOWN, THE CONTRACTOR MUST PROVIDE
ALL TEMPORARY AND PERMANENT BRACING AS REQUIRED FOR SAFE ERECTION
OF THE TRUSSES, OR AS RECOMMENDED BY THE MANUFACTURER. THE
GUIDELINES SET FORTH IN THE TRUSS PLATE INSTITUTE PUBLICATION "BRACING
WOOD TRUSSES, COMMENTARY AND RECOMMENDATIONS" MUST BE
CONSIDERED AS MINIMUM REQUIREMENTS.
8. PROVIDE ALL ADDITIONAL BRACING OF BOTH WEB AND CHORD MEMBERS
REQUIRED BY THE TRUSS SHOP DRAWINGS.
9. ALL CONNECTION HARDWARE FOR TRUSS-TO-TRUSS CONNECTIONS AND TRUSS
TO SUPPORTING STRUCTURE CONNECTIONS MUST BE SUPPLIED BY THE
MANUFACTURER.
10. FOR ADJACENT TRUSSES WHERE THE WEB CONFIGURATION IS CAPABLE OF
CONTAINING A RECTANGLE 42 INCHES HIGH BY 24 INCHES WIDE OR GREATER
BETWEEN TOP OF THE BOTTOM CHORD AND THE BOTTOM OF ANY OTHER TRUSS
MEMBER, SUCH AREAS MUST HAVE THE BOTTOM CHORD DESIGNED FOR A LIVE
LOAD OF 20 PSF IN ADDITION TO ANY OTHER LOADS SHOWN.
PREFABRICATED METAL-PLATE-
CONNECTED WOOD TRUSS NOTES:
AFF
ARCH
BD
BF
BEJ
BLDG
BM
BOD
BOT, B
BRG
BTWN
C TO C
CFMF
CJ
CL
CLR
CMU
COL
CONC
CONN
CONSTR
CONT
COORD
CTR
CTRD
CW
DBL
DCJ
DIA, Ø
DJ
DWGS
EA
EF
EJ
EL
ELEV
EMBED
EOD
EOS
EQ
EW
EXIST
EXP
EXT
FD
FDN
FO
FF EL
FIN
FIN FLR
FOB
FOC
FOM
FOS
FRMG
FTG
FV, ±
GALV
GEN
GR BM
H
HK
HORIZ
HSS
HT
ABOVE FINISHED FLOOR
ARCHITECT
BAR DIAMETER
BRACED FRAME
BUILDING EXPANSION JOINT
BUILDING
BEAM
BOTTOM OF DECK
BOTTOM
BEARING
BETWEEN
CENTER TO CENTER
COLD-FORMED METAL
FRAMING
CONTROL JOINT
CENTERLINE
CLEAR
CONCRETE MASONRY UNIT
COLUMN
CONCRETE
CONNECTION
CONSTRUCTION
CONTINUOUS
COORDINATE
CENTER
CENTERED
CURTAIN WALL
DOUBLE
DOWELED CONSTRUCTION
JOINT
DIAMETER
DOUBLE JOIST
DRAWINGS
EACH
EACH FACE
EXPANSION JOINT
ELEVATION
ELEVATOR
EMBEDMENT
EDGE OF DECK
EDGE OF SLAB
EQUAL
EACH WAY
EXISTING
EXPANSION
EXTERIOR
FLOOR DRAIN
FOUNDATION
FACE OF
FINISHED FLOOR
ELEVATION
FINISH
FINISHED FLOOR
FACE OF BUILDING
FACE OF CONCRETE
FACE OF MASONRY
FACE OF SLAB/ STUD
FRAMING
FOOTING
FIELD VERIFY
GALVANIZED
GENERAL
GRADE BEAM
HIGH
HOOK
HORIZONTAL
HOLLOW STRUCTURAL
SECTION
HEIGHT
HVY
INT
JBE
JT
KCJ
L
LLH
LLV
LSH
LSV
LTWT
LWC
MAS
MATL
MAX
MECH
MF
MFR
MID
MIN
MOD
MOS
NOM
NTS
OC
OPH
OPNG
PAF
PAR
PC
PEMB
PEN
PERP
PL
R
REF
REINF
REQD
REQMTS
SCHED
SF
SGB
SIM
SJ
SL
SOG
SPF
STD
TBE
T&B T&G
THK
TOC
TOF
TOM
TOP
TOS
TS
TYP
UON
VERT
W/
WP
WSP
WWR
HEAVY
INTERIOR
JOIST BEARING ELEVATION
JOINT
KEYED CONSTRUCTION JOINT
LOW
LONG LEG HORIZONTAL
LONG LEG VERTICAL
LONG SIDE HORIZONTAL
LONG SIDE VERTICAL
LIGHTWEIGHT
LIGHTWEIGHT CONCRETE
MASONRY
MATERIAL
MAXIMUM
MECHANICAL
MOMENT FRAME
MANUFACTURER
MIDDLE
MINIMUM
MODIFY
MIDDEPTH OF SLAB
NOMINAL
NOT TO SCALE
ON CENTER
OPPOSITE HAND
OPENING
POWDER ACTUATED
FASTENER
PARALLEL
PIECE
PRE-ENGINEERED METAL
BUILDING
PENETRATE, PENETRATION
PERPENDICULAR
PLATE
RADIUS
REFERENCE, REFER TO
REINFORCE, REINFORCED,
REINFORCING
REQUIRED
REQUIREMENTS
SCHEDULE
STEPPED FOOTING
STEPPED GRADE BEAM
SIMILAR
SAWED JOINT
SLOPE
SLAB-ON-GRADE
SIDEPLATE FRAME
STANDARD
TRUSS BEARING ELEVATION
TOP & BOTTOM
TONGUE AND GROOVE
THICKNESS
TOP OF CONCRETE
TOP OF FOOTING
TOP OF MASONRY
TOP OF PEDESTAL
TOP OF STEEL
THICKENED SLAB
TYPICAL
UNLESS OTHERWISE NOTED
VERTICAL
WITH
WORKING POINT
WOOD STRUCTURAL PANEL(S)
WELDED WIRE REINFORCING
ABBREVIATIONS:
XXX#
XXX#
X
= TOP OF STEEL ELEVATION MEASURED
FROM REFERENCED FINISHED FIRST
FLOOR ELEVATION = 0'-0"
= TOP OF MASONRY ELEVATION MEASURED
FROM REFERENCED FINISHED FIRST
FLOOR ELEVATION = 0'-0"
= TRUSS BEARING ELEVATION MEASURED
FROM REFERENCED FINISHED FIRST
FLOOR ELEVATION = 0'-0"
= JOIST BEARING ELEVATION MEASURED
FROM REFERENCED FINISHED FIRST
FLOOR ELEVATION = 0'-0"
= BOTTOM OF DECK ELEVATION MEASURED
FROM REFERENCED FINISHED FIRST
FLOOR ELEVATION = 0'-0"
= MECHANICAL UNIT SUPPORTED ABOVE
FRAMING (WEIGHT IN POUNDS) -
COORDINATE W/ MECH DWGS
= MECHANICAL UNIT SUPPORTED BELOW
FRAMING (WEIGHT IN POUNDS) -
COORDINATE W/ MECH DWGS
= FLOOR / ROOF OPENING
= TOP OF FOOTING ELEVATION MEASURED
FROM REFERENCED FINISHED FIRST
FLOOR ELEVATION = 0'-0"
(-X'-X")
= TOP OF PILE CAP / GRADE BEAM ELEVATION
MEASURED FROM REFERENCED FINISHED
FIRST FLOOR ELEVATION = 0'-0"
= TOP OF EXISTING FOOTING ELEVATION
MEASURED FROM REFERENCED FINISHED
FIRST FLOOR ELEVATION = 0'-0"
<-X'-X">
= TOP OF SLAB ELEVATION MEASURED
FROM REFERENCED FINISHED FIRST
FLOOR ELEVATION = 0'-0"
= CHANGE IN ELEVATION -
REF ARCH DWGS FOR DIMENSIONS
= DIRECTION OF SLOPE
KCJ, CJ, OR SJ LINE ON PLAN=
WARP LINE OF ROOF DECK=
S F
S F
PIPE
PIPE CROSSING FOOTING=
PLAN KEY NOTE MARK=
COLUMN GRID MARK=
X
SX
SECTION/DETAIL MARK=
SECTION/DETAIL NUMBER/LETTER
SHEET NUMBER WHERE
SECTION/DETAIL MARK IS DRAWN
MOMENT CONNECTION=
JOIST BOTTOM CHORD EXTENSION=
BEAM BOTTOM FLANGE BRACE=
BEAM SPLICE=
KNUCKLED BEAM=
HORIZONTAL BRIDGING=
CROSS BRIDGING=
TRUSS MARK=T-X
BEARING PLATE MARK=BP-X
CONCRETE / STEEL LINTEL MARK=L-X
WALL FOOTING MARK=WFX
COLUMN FOOTING MARK=CFX
FIELD VERIFY=±
S-X
SLAB MARK / SPAN DIRECTION=
(-X'-X")
PLAN LEGEND:
W16x26 (36) [2"]
BEAM SIZE
NUMBER OF
HEADED STUDS
CAMBER
REACTION (KIPS)
COMPOSITE BEAM NOTATION=
70k 35k
SL
X
TOS = +X'-X"
TOM = +X'-X"
TBE = +X'-X"
JBE = +X'-X"
BOD = +X'-X"
X'-X"
KB
SHEAR WALL MARK=SW-X
BEARING WALL MARK=BW-X
OVERBUILT FRAMING=
1. COLD-FORMED METAL FRAMING MUST BE IN ACCORDANCE WITH THE AMERICAN
IRON AND STEEL INSTITUTE (AISI) "NORTH AMERICAN STANDARD FOR COLD-
FORMED STEEL FRAMING - GENERAL PROVISIONS".
2. SUBMIT SHOP DRAWINGS SIGNED AND SEALED BY A VIRGINIA LICENSED
PROFESSIONAL ENGINEER RESPONSIBLE FOR THE DESIGN OF COLD-FORMED
METAL FRAMING. SHOP DRAWINGS MUST INCLUDE DESIGN LOADINGS AND
REACTIONS APPLIED TO THE SUPPORTING STRUCTURE. INCLUDE PLACING
DRAWINGS FOR FRAMING MEMBERS SHOWING SIZE AND GAGE DESIGNATIONS,
NUMBER, TYPE, LOCATION AND SPACING. INDICATE CONNECTIONS,
SUPPLEMENTAL STRAPPING, BRACING, SPLICES, BRIDGING, ACCESSORIES AND
DETAILS AND CONSTRUCTION SEQUENCE REQUIRED FOR PROPER AND SAFE
INSTALLATION. INCLUDE ALL TRUSS SPLICE DETAILS AND TRUSS TO TRUSS
CONNECTION DETAILS. SECONDARY BENDING STRESSES IN TRUSS TOP AND
BOTTOM CHORDS DUE TO MEMBER LOADS MUST BE CONSIDERED IN THE
DESIGN.
3. WELDING MUST BE IN ACCORDANCE WITH AWS D1.3, "STRUCTURAL WELDING
CODE - SHEET STEEL". TOUCH UP ALL WELDS WITH SPECIFIED COATING
SYSTEMS.
4. COLD-FORMED METAL FRAMING MEMBERS MUST CONFORM TO ASTM C955, AND
BE FORMED OF CORROSION-RESISTANT STEEL CONFORMING TO ASTM A653 AND
ASTM C955 WITH A MINIMUM YIELD STRENGTH OF 33 KSI FOR 43 MIL AND
THINNER MEMBERS AND 50 KSI FOR ALL OTHER MEMBERS.
5. MEMBER SECTION PROPERTIES MUST CONFORM TO PART 'I' OF THE "COLD-
FORMED STEEL DESIGN MANUAL."
6. COLD-FORMED METAL FRAMING MEMBERS, HEADERS AND CONNECTIONS
SHOWN ON STRUCTURAL AND ARCHITECTURAL DRAWINGS ARE SCHEMATIC
ONLY AND MUST BE DESIGNED TO MEET PERFORMANCE SPECIFICATION
REQUIREMENTS.
7. PROVIDE BRIDGING LINES AT 4'-0" MAXIMUM ON CENTER IN ALL WALLS UNLESS
OTHERWISE INDICATED. BRIDGING MUST BE FULLY INSTALLED AND ANCHORED
AT ENDS BEFORE SUPERIMPOSING LOADS ONTO THE STUDS.
8. COLD-FORMED METAL FRAMING DESIGN LOADS MUST BE AS INDICATED IN THE
"GENERAL NOTES".
COLD-FORMED METAL FRAMING NOTES:
1. ALL POST INSTALLED ANCHORS INDICATED ON THE DRAWINGS ARE BY HILTI,
INC, AND MUST BE CONSIDERED THE BASIS OF DESIGN PRODUCT. WHERE NOT
EXPLICITLY INDICATED IN THE DRAWINGS, THE FOLLOWING
ANCHORS/ADHESIVES MUST BE USED:
A. ANCHORAGE TO CONCRETE
1. ADHESIVE ANCHORS FOR CRACKED AND UNCRACKED CONCRETE USE:
a. HILTI HIT-HY 200 SAFE SET SYSTEM WITH HILTI HOLLOW DRILL BIT
(TE-CD OR TE-YD) AND VC 20/40 VACUUM SYSTEM (VC 20-U OR
VC40U) WITH STEEL THREADED ROD PER ICC ESR-3187.
2. SCREW ANCHORS FOR CRACKED AND UNCRACKED CONCRETE USE:
a. HILTI KWIK HUS EZ SCREW ANCHORS PER ICC ESR-3027.
B. REBAR DOWELING INTO CONCRETE
1. ADHESIVE ANCHORS FOR CRACKED AND UNCRACKED CONCRETE USE:
a. HILTI HIT-HY 200 SAFE SET SYSTEM WITH HILTI HOLLOW DRILL BIT
(TE-CD OR TE-YD) AND VC 20/40 VACUUM SYSTEM (VC 20-U OR VC
40-U) WITH CONTINUOUSLY DEFORMED REBAR PER ICC ESR-3187.
C. ANCHORAGE TO SOLID GROUTED MASONRY
1. ADHESIVE ANCHORS USE:
a. HILTI HIT-HY 270 MASONRY ADHESIVE ANCHORING SYSTEM (ICC
PENDING).
b. STEEL ANCHOR ELEMENT MUST BE HILTI HAS-E CONTINUOUSLY
THREADED ROD.
2. MECHANICAL ANCHORS USE:
a. HILTI KWIK HUS EZ SCREW ANCHORS PER ICC ESR 3056.
2. ALTERNATE POST INSTALLED ANCHOR PRODUCTS MAY BE SUBMITTED TO THE
ENGINEER FOR REVIEW AND POSSIBLE APPROVAL. ALL SUBSTITUTION
REQUESTS MUST BE ACCOMPANIED BY AN ICC ESR SHOWING COMPLIANCE WITH
THE RELEVANT BUILDING CODE FOR SEISMIC USES, LOAD RESISTANCE,
INSTALLATION CATEGORY, AND COMPREHENSIVE INSTALLATION INSTRUCTIONS.
ADHESIVE ANCHOR EVALUATION WILL ALSO CONSIDER CREEP, IN-SERVICE
TEMPERATURE AND INSTALLATION TEMPERATURE. ALTERNATE PRODUCTS MAY
REQUIRE MODIFICATIONS TO ANCHOR DIAMETER, SPACING, AND EMBEDMENT.
3. INSTALL ANCHORS PER THE MANUFACTURER INSTRUCTIONS, AS INCLUDED IN
THE ANCHOR PACKAGING.
4. THE CONTRACTOR MUST ARRANGE FOR AN ANCHOR MANUFACTURER'S
REPRESENTATIVE TO PROVIDE ONSITE INSTALLATION TRAINING FOR ALL OF
THEIR ANCHORING PRODUCTS SPECIFIED. THE STRUCTURAL ENGINEER OF
RECORD MUST RECEIVE DOCUMENTED CONFIRMATION THAT ALL OF THE
CONTRACTOR'S PERSONNEL WHO INSTALL ANCHORS ARE TRAINED PRIOR TO
THE COMMENCEMENT OF ANCHOR INSTALLATION.
5. ANCHOR CAPACITY IS DEPENDANT UPON SPACING BETWEEN ADJACENT
ANCHORS AND PROXIMITY OF ANCHORS TO EDGE OF CONCRETE. INSTALL
ANCHORS IN ACCORDANCE WITH SPACING AND EDGE CLEARANCES INDICATED
ON THE DRAWINGS.
6. EXISTING REINFORCING BARS IN THE CONCRETE STRUCTURE MAY CONFLICT
WITH SPECIFIC ANCHOR LOCATIONS. UNLESS NOTED ON THE DRAWINGS THAT
THE BARS CAN BE CUT, THE CONTRACTOR MUST LOCATE THE POSITION OF THE
REINFORCING BARS AT THE LOCATIONS OF THE CONCRETE ANCHORS, BY
FERROSCAN OR GPR.
7. ALL POST INSTALLED ANCHORS REQUIRE CONTINUOUS INSPECTIONS BY THE
OWNER'S MATERIALS TESTING AGENCY TO VERIFY INSTALLATION HAS BEEN
PERFORMED IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN
INSTRUCTIONS.
POST-INSTALLED ANCHOR NOTES:
C O M M O
N W
EA
LTH OF
V I
R G I N I A
P R O F
E
SS IONAL EN
G
IN
E E R
Structural Engineers 1519 Summit Ave., Suite 101
Richmond, VA 23230
804.346.3935 - lynchmykins.com
All ideas, designs, arrangements and plans indicated or represented by this drawing are property of ENTEROS DESIGN, PC; created, evolved and developed for the sole use of this project. These ideas, design arrangements and/or plans shall not be used by or disclosed to any person, firm or corporation for any purpose without written permission from ENTEROS DESIGN, PC. Written dimensions on these drawings shall have precedence over scaled dimensions. Contractors shall verify and be responsible for all dimensions and conditions on the job. The Architect must be notified of any variations from the dimensions and conditions shown on these drawings.
© 2022 ENTEROS DESIGN, PC
7 NORTH 25TH STREET
RICHMOND, VA 23223
804.861.1200 P
4/14/23
W A
TE
R
S
TR
EE
T
R E
ST
A U
R A
N T
Y O
R K
TO
W
N V
IR
G
IN
IA
S0.02
PROJ. NO.: 211005
DATE: 04/14/23
DRAWN BY: BRW
GENERAL NOTES
CONSTRUCTION
DOCUMENTS
Lic. No. 017580
JOHN H. HANCOCK
REVISIONS
D E F G H I J K L M N O P Q R
7.1
7.8
9.1
8.1
4.5
2.1
S3.02
0.5
R.1
1.9
CBA
2.4
4.8
AA AB
CF4
CF3 CF3 CF3
CF3
CF4 CF3 CF3 CF4
CF4 CF4
CF3 CF3
CF5
CF4 CF4
CF5
CF3
CF4
CF3
CF5
CF4
CF4
CF3
CF5 CF5 CF5
CF5CF5
CF4
CF4
CF3
CF3
CF3
CF3
CF3
CF4
CF5 CF5 CF4 CF5
CF4
CF3
22'-11" 1'-2" 8'-11" 12'-8" 8'-11" 8'-9 1/2" 7'-3" 8'-9 1/2" 22'-6" 8'-9 1/2" 7'-3" 8'-9 1/2" 22'-6" 8'-6" 3'-0"
1'-0 1/2"
14'-5"
1'-0 1/2"
3'-0" 4'-6" 12'-0"
6"
HSS6x 6x
3/
HSS6x 6x
3/
HSS6x 6x
3/
HSS6x 6x
3/
HSS6x 6x
3/
HSS6x 6x
3/
HSS6x 6x
3/
HSS6x 6x
3/
HSS6x 6x
3/
HSS6x6x3/8
HSS6x 6x
3/
HSS6x 6x
3/
HSS6x 6x
3/
HSS6x 6x
3/
HSS6x 6x
3/
HSS6x 6x
3/
HSS6x 6x
3/
HSS6x 6x
3/
HSS5x 5x
1/
HSS5x 5x
1/
HSS5x 5x
1/
HSS5x 5x
1/
HSS5x 5x
1/
HSS6x 6x
3/
HSS6x 6x
3/
HSS6x 6x
3/
HSS6x6x1/4HSS6x 6x
1/
HSS4x 4x
1/
HSS4x 4x
1/
HSS4x 4x
1/
HSS4x 4x
1/
HSS8x 8x
1/
HSS8x 8x
1/
HSS8x 8x
1/
HSS8x 8x
1/
HSS8x 8x
1/
HSS8x 8x
1/
HSS8x 8x
1/
HSS6x 6x
3/
HSS6x 6x
3/
HSS6x 6x
3/
HSS6x6x3/8 HSS6x
6x 3/
8 HSS6x6x3/8
HSS6x6x3/8
HSS6x6x3/8
HSS6x 6x
3/
HSS6x 6x
3/
HSS6x 6x
3/
HSS6x 6x
3/
HSS6x 6x
1/
HSS5x 5x
1/
HSS5x 5x
1/
HSS6x 6x
1/
HSS6x 6x
1/
HSS6x 6x
1/
HSS6x 6x
1/
CF3
CF3CF3
CF3
CF3CF3CF3
CF3
CF3CF3CF3
CF3
CF4 CF3 CF3 CF4
CF4 CF3
CF3
CF3
CF3CF4
CF4CF3CF3CF4
CF3
S3.01
S3.01
WF2
N.1 N.9
11.1
12.4
14'-5"
CF3 CF3
CF3CF3
HSS6x 6x
3/
TYP O
F 4
WF2
W F
05 05
WF2.5 (TYP UON)
WF2.5 (TYP UON)
CF3 CF3
CF3
CF3 CF3 CF3 CF3 CF3 CF3 CF3 CF3 CF3
S3.03
S3.03
S F
WF2.5 (TYP UON)
WF2
WF2.5 (TYP UON)
3 EQ SPACES
COORD W/ ARCH
3 EQ SPACES 3 EQ SPACES
8'-6"
COORD W/ ARCH
3 EQ SPACES 2 EQ SPACES
S3.01
S3.01
S3.01
TYP
TYP
-2
'-0
2'-0
-2
'-0
T Y
PS
F
S F
( -2 '-0
( -4 '-0
S F
S F
-1
'-4
( -3 '-4
W F
( -2 '-0
TYP
< -2'-0" >
TYP
S F
S F (
-1 '-4
-3
S F
S F (
-1 '-4
-3
'-4
'-0
T Y
P3'-0"
/4
( -2'-0" ) ±
S3.04
S3.04
S3.04
/2
/2
52'-0 1/8"
11'-7 7/8" 28'-8 3/8" 11'-7 7/8"
/8
R
4'
3/
6"
/8
14'-4 1/4"
S3.04
/8
S3.01
EQ EQ EQ
/2
0'-8 1/4" 1'-4 7/8"
01 TYP
TYP
TYP
( -4 '-0
( -2
'-0
C O M M O
N W
EA
LTH OF
V I
R G I N I A
P R O F
E
SS IONAL EN
G
IN
E E R
Structural Engineers 1519 Summit Ave., Suite 101
Richmond, VA 23230
804.346.3935 - lynchmykins.com
All ideas, designs, arrangements and plans indicated or represented by this drawing are property of ENTEROS DESIGN, PC; created, evolved and developed for the sole use of this project. These ideas, design arrangements and/or plans shall not be used by or disclosed to any person, firm or corporation for any purpose without written permission from ENTEROS DESIGN, PC. Written dimensions on these drawings shall have precedence over scaled dimensions. Contractors shall verify and be responsible for all dimensions and conditions on the job. The Architect must be notified of any variations from the dimensions and conditions shown on these drawings.
© 2022 ENTEROS DESIGN, PC
7 NORTH 25TH STREET
RICHMOND, VA 23223
804.861.1200 P
4/14/23
W A
TE
R
S
TR
EE
T
R E
ST
A U
R A
N T
Y O
R K
TO
W
N V
IR
G
IN
IA
S1.01
PROJ. NO.: 211005
DATE: 04/14/23
DRAWN BY: BRW
FOUNDATION PLAN
CONSTRUCTION
DOCUMENTS
FOUNDATION / SLAB-ON-GRADE PLAN NOTES
A. REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS TO NONBEARING
WALLS, WALL CONTROL JOINTS AND OPENINGS.
B. UNLESS OTHERWISE NOTED, ALL ELEVATIONS ARE BASED ON A FINISHED
FIRST FLOOR REFERENCE ELEVATION OF 0'-0". ACTUAL FINISHED FLOOR
ELEVATION IS 7.90'± (MATCH EXISTING). REFER TO ARCHITECTURAL
DRAWINGS FOR FINISHED FLOOR MATERIAL.
C. TOP OF ALL NEW FOOTINGS SHALL BE AT ELEVATION -1'-4" UNLESS
OTHERWISE NOTED.
D. NOT ALL UTILITY LOCATIONS ARE SHOWN ON PLAN. THE CONTRACTOR
SHALL COORDINATE THE LOCATIONS, SIZES, AND INVERTS OF UTILITIES. AT
LOCATIONS WHERE UTILITIES PASS BELOW THE TOP OF FOOTING
ELEVATION, STEP THE TOP OF FOOTING DOWN ON EACH SIDE PER THE
"STEPPED FOOTING DETAIL" AND SLEEVE THE UTILITY THROUGH THE
FOUNDATION WALL. THE CONTRACTOR MAY, AT THEIR OPTION, SLEEVE
THE UTILITY THROUGH THE FOUNDATION PER THE "UTILITY SLEEVE
DETAIL." ALL PENETRATIONS IN MASONRY WALLS GREATER THAN 1'-4"
REQUIRE A BOND BEAM LINTEL.
E. UNLESS OTHERWISE INDICATED, EXTEND WALL FOOTINGS A MINIMUM OF 6
INCHES BEYOND ENDS OF WALLS.
F. SLAB-ON-GRADE JOINTS SHALL BE SAWED JOINTS OR KEYED
CONSTRUCTION JOINTS UNLESS SPECIFICALLY DENOTED TO BE KEYED
CONSTRUCTION JOINTS. CONTRACTOR SHALL COORDINATE ALL SLAB
JOINTS WITH JOINTS IN BONDED FLOOR FINISHES. REFER TO
ARCHITECTURAL DRAWINGS FOR FLOOR FINISH JOINT LOCATIONS.
G. PLACE 1 - #4 x 3’-0” IN MIDDLE OF SLAB AT REENTRANT CORNERS WHERE A
SLAB CONTROL JOINT DOES NOT OCCUR.
H. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LIMITS OF SLAB
DEPRESSIONS.
J. FLOOR DRAINS AND FLOOR SINKS ARE NOT SHOWN ON PLAN. REFER TO
PLUMBING DRAWINGS FOR LOCATIONS.
K. REFER TO CIVIL DRAWINGS FOR EXTERIOR CONCRETE SLABS AND PAVING.
KEY NOTES
01 REFER TO TYPICAL DETAIL AT INTERSECTION OF NEW AND EXISTING
FOOTINGS.
05 ASSUMED EXISTING STEEL COLUMNS AND FOUNDATION AT COVERED
OUTDOOR AREA. FIELD VERIFY.
16 REMOVE ASSUMED EXISTING WOOD STUD WALL AND REPLACE WITH NEW
6" CFMF STUD WALL.
21 CMU PIER. REFER TO SECTION 2/S3.01 FOR PIER REINFORCING.
22 EXISTING UTILITY LINE. STEP FTG AND CORE NEW WALL FOOTING AS
REQUIRED FOR COORDINATION. REFER TO TYPICAL PIPE SLEEVE DETAILS
ON S5.01.
23 EXISTING UTILITY LINE. GC MUST COORDINATE THEIR EXCAVATION IN THIS
AREA TO AVOID DISTURBANCE OF EXISTING UTILITY LINE.
1/8" = 1'-0"
FOUNDATION PLAN
COLUMN FOOTING SCHEDULE
MARK
SIZE REINFORCING
REMARKSLENGTH WIDTH DEPTH BOTTOM TOP
CF3 3' - 0" 3' - 0" 1'-0" 3 - #5 EW - -
WALL FOOTING SCHEDULE
MARK
SIZE REINFORCING
REMARKSWIDTH DEPTH CONTINUOUS TRANSVERSE
WF2 2' - 0" 1'-0" 2 - #5 BOT #5 AT 48" OC BOT -
WF2.5 2' - 6" 1'-0" 3 - #5 BOT #5 AT 48" OC BOT -
Lic. No. 017580
JOHN H. HANCOCK
REVISIONS
7.1
7.8
9.1
8.1
4.5
2.1
S3.02
0.5
R.1
1.9
CBA
2.4
4.8
AA AB
S3.01
S3.01
N.1 N.9
11.1
12.4
S3.03
S3.03
S3.01
S3.01
S3.01
S3.04
TYP
TYP
S3.04
S3.04
TS
TS
S3.04
C O M M O
N W
EA
LTH OF
V I
R G I N I A
P R O F
E
SS IONAL EN
G
IN
E E R
Structural Engineers 1519 Summit Ave., Suite 101
Richmond, VA 23230
804.346.3935 - lynchmykins.com
All ideas, designs, arrangements and plans indicated or represented by this drawing are property of ENTEROS DESIGN, PC; created, evolved and developed for the sole use of this project. These ideas, design arrangements and/or plans shall not be used by or disclosed to any person, firm or corporation for any purpose without written permission from ENTEROS DESIGN, PC. Written dimensions on these drawings shall have precedence over scaled dimensions. Contractors shall verify and be responsible for all dimensions and conditions on the job. The Architect must be notified of any variations from the dimensions and conditions shown on these drawings.
© 2022 ENTEROS DESIGN, PC
7 NORTH 25TH STREET
RICHMOND, VA 23223
804.861.1200 P
4/14/23
W A
TE
R
S
TR
EE
T
R E
ST
A U
R A
N T
Y O
R K
TO
W
N V
IR
G
IN
IA
S1.02
PROJ. NO.: 211005
DATE: 04/14/23
DRAWN BY: BRW
SLAB ON GRADE
PLAN
CONSTRUCTION
DOCUMENTS
1/8" = 1'-0"
SLAB ON GRADE PLAN
FOUNDATION / SLAB-ON-GRADE PLAN NOTES
A. REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS TO NONBEARING
WALLS, WALL CONTROL JOINTS AND OPENINGS.
B. UNLESS OTHERWISE NOTED, ALL ELEVATIONS ARE BASED ON A FINISHED
FIRST FLOOR REFERENCE ELEVATION OF 0'-0". ACTUAL FINISHED FLOOR
ELEVATION IS 7.90'± (MATCH EXISTING). REFER TO ARCHITECTURAL
DRAWINGS FOR FINISHED FLOOR MATERIAL.
C. TOP OF ALL NEW FOOTINGS SHALL BE AT ELEVATION -1'-4" UNLESS
OTHERWISE NOTED.
D. NOT ALL UTILITY LOCATIONS ARE SHOWN ON PLAN. THE CONTRACTOR
SHALL COORDINATE THE LOCATIONS, SIZES, AND INVERTS OF UTILITIES. AT
LOCATIONS WHERE UTILITIES PASS BELOW THE TOP OF FOOTING
ELEVATION, STEP THE TOP OF FOOTING DOWN ON EACH SIDE PER THE
"STEPPED FOOTING DETAIL" AND SLEEVE THE UTILITY THROUGH THE
FOUNDATION WALL. THE CONTRACTOR MAY, AT THEIR OPTION, SLEEVE
THE UTILITY THROUGH THE FOUNDATION PER THE "UTILITY SLEEVE
DETAIL." ALL PENETRATIONS IN MASONRY WALLS GREATER THAN 1'-4"
REQUIRE A BOND BEAM LINTEL.
E. UNLESS OTHERWISE INDICATED, EXTEND WALL FOOTINGS A MINIMUM OF 6
INCHES BEYOND ENDS OF WALLS.
F. SLAB-ON-GRADE JOINTS SHALL BE SAWED JOINTS OR KEYED
CONSTRUCTION JOINTS UNLESS SPECIFICALLY DENOTED TO BE KEYED
CONSTRUCTION JOINTS. CONTRACTOR SHALL COORDINATE ALL SLAB
JOINTS WITH JOINTS IN BONDED FLOOR FINISHES. REFER TO
ARCHITECTURAL DRAWINGS FOR FLOOR FINISH JOINT LOCATIONS.
G. PLACE 1 - #4 x 3’-0” IN MIDDLE OF SLAB AT REENTRANT CORNERS WHERE A
SLAB CONTROL JOINT DOES NOT OCCUR.
H. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LIMITS OF SLAB
DEPRESSIONS.
J. FLOOR DRAINS AND FLOOR SINKS ARE NOT SHOWN ON PLAN. REFER TO
PLUMBING DRAWINGS FOR LOCATIONS.
K. REFER TO CIVIL DRAWINGS FOR EXTERIOR CONCRETE SLABS AND PAVING.
KEY NOTES
11 ALTERNATE: NEW THICKENED SLAB AT NEW
AQUARIUM. REFER TO ARCH DWGS.
19 NEW THICKENED SLAB AT SCREEN WALLS. REFER TO
ARCH DWGS FOR THE STEEL FRAME
20 4" CONCRETE SLAB-ON-GRADE OVER VAPOR
RETARDER AND 4" DEPTH OF POROUS FILL UNLESS
OTHERWISE INDICATED. REINFORCE SLAB WITH
6x6-W2.1xW2.1 WELDED WIRE REINFORCING PLACED 1"
CLEAR BELOW TOP OF SLAB. MAINTAIN
REINFORCEMENT IN POSITION ON BOLSTERS, CHAIRS
OR SPACERS DURING CONCRETE PLACEMENT.
24 REMOVE AND REPLACE EXISTING CONCRETE SLAB AS
REQUIRED FOR INSTALLATION OF NEW CONDUITS.
REFER TO TYPICAL SLAB REMOVAL AND REPLACEMENT
DETAIL.
34 NEW HOUSEKEEPING PAD FOR STORAGE TANKS.
COORDINATE SIZE WITH MEP DWGS. REFER TO
TYPICAL HOUSEKEEPING PAD ON S5.01.
37 THICKENED SLABS ARE UNDER NEW COLD FORMED
METAL FRAMING WALLS SUPPORTING THE
MECHANICAL PLATFORM ABOVE-REF ARCH FOR
LOCATION. REFERENCE TYPICAL DETAIL ON S5.01
Lic. No. 017580
JOHN H. HANCOCK
REVISIONS
# DATE DESCRIPTION
1 05/09/2023 ADDENDUM 1
7.1
7.8
9.1
8.1
4.5
2.1
S3.02
W16x40 W16x40 W16x40
W x
W16x40 W16x40 W16x40
W x
W x
HSS12x4x1/4 HSS12x4x1/4
H S
S x x /4
HSS12x4x1/4
W x
W x
W x
W x
W12x19 W12x19 W12x19
W16x26
W12x19 W12x19 W12x19
W16x26
H S
S x x /4
H S
S x x /4
W x
W x
W x
W x 2 HSS12x6x1/2 - L
HSS12x6x5/16 - L
W16x26
HSS12x6x1/2 - L
H S
S x x /4
W10x33
W10x33
W10x33
W x
W x
W10x33
H S
S x x /4
W10x33
W12x40
W12x40
W16x26
H S
S x x /4
W x
HSS12x4x1/4
W x
22'-11"
1'-2"
8'-11" 12'-8" 8'-11" 8'-9 1/2" 7'-3" 8'-9 1/2" 22'-6" 8'-9 1/2" 7'-3" 8'-9 1/2" 22'-6" 8'-6" 3'-0"
1'-0 1/2"
14'-5"
1'-0 1/2"
3'-0" 4'-6" 12'-0" 6"
9 3/4"
/2
/2
S3.02
S3.02
0.5
R.1
1.9
CBA
2.4
4.8
AA AB
W10x33
H S
S x x /4
W10x33
W16x26
W18x46
W x
W x
W x
W x
H S
S x x /4
H S
S x x /4
W x
W12x35
W x
W12x35 W12x35
W x
W x
W12x35 W12x35 W12x35
W x
W x
W12x35 W12x35 W12x35
W12x35
S3.01
S3.01
N.1 N.9
11.1
12.4
W14x22
S3.01
S3.01
S3.01
W10x33
W10x33
W x
W x
03 (4) 2x12
02 02
S3.03
S3.03
1515 15
RTU-1 - MAX
WT = 2500#
RTU-2 - MAX
WT = 2500#
RTU-3 - MAX
WT = 2500#
RTU-4 - MAX
WT = 2500#
HP-1 - MAX
WT = 700#
MAU-3 - MAX
WT = 2500#
S3.01
SIM TO
S3.02
S3.03
S3.03
S3.03
TOS = +9'-10"
UON
TOS = +10'-9 1/2"
TOS = +10'-9 1/2"
TOS = +10'-9 1/2"
S3.01
SIM TO
W x
W10x33
2x12 - DBL 26
LOW
W x
W x
W10x12
W8x18
S1.03
TYP
25 25
S3.03
S3.01
S3.03 _________ 40
2x12 - DBL
1 1 1
Q R
S3.03
S3.03
S3.03
SIM
C O M M O
N W
EA
LTH OF
V I
R G I N I A
P R O F
E
SS IONAL EN
G
IN
E E R
Structural Engineers 1519 Summit Ave., Suite 101
Richmond, VA 23230
804.346.3935 - lynchmykins.com
All ideas, designs, arrangements and plans indicated or represented by this drawing are property of ENTEROS DESIGN, PC; created, evolved and developed for the sole use of this project. These ideas, design arrangements and/or plans shall not be used by or disclosed to any person, firm or corporation for any purpose without written permission from ENTEROS DESIGN, PC. Written dimensions on these drawings shall have precedence over scaled dimensions. Contractors shall verify and be responsible for all dimensions and conditions on the job. The Architect must be notified of any variations from the dimensions and conditions shown on these drawings.
© 2022 ENTEROS DESIGN, PC
7 NORTH 25TH STREET
RICHMOND, VA 23223
804.861.1200 P
4/14/23
W A
TE
R
S
TR
EE
T
R E
ST
A U
R A
N T
Y O
R K
TO
W
N V
IR
G
IN
IA
S1.03
PROJ. NO.: 211005
DATE: 04/14/23
DRAWN BY: BRW
ROOF FRAMING
PLAN
CONSTRUCTION
DOCUMENTS
FRAMING PLAN NOTES
A. REFER TO FOUNDATION PLAN AND ARCHITECTURAL DRAWINGS FOR
DIMENSIONS NOT SHOWN.
B. PREFABRICATED WOOD TRUSSES AT 24" OC MAXIMUM.
C. TOP OF ROOF STEEL ELEVATIONS ARE SHOWN ON PLAN.
INTERMEDIATE ELEVATIONS SHALL BE STRAIGHT LINES BETWEEN
GIVEN ELEVATIONS. INTERPOLATE AS REQUIRED FOR INTERMEDIATE
BEARING ELEVATIONS, UNLESS OTHERWISE NOTED.
D. COORDINATE AND VERIFY ALL MEMBER LOCATIONS, DIMENSIONS,
WEIGHTS, OPENING SIZES, AND CURB DIMENSIONS FOR ALL
MECHANICAL EQUIPMENT WITH THE ACTUAL EQUIPMENT FURNISHED.
INCLUD THIS INFORMATION ON THE JOIST AND STRUCTURAL STEEL
SHOP DRAWINGS.
KEY NOTES
02 NEW PREFABRICATED ROOF TRUSSES AT 24" OC MAX.
03 ROOF OVERFRAMING. REFER TO TYPICAL BUILT-UP ROOF FRAMING DETAILS
04 EXISTING 2X8 AT 16" OC.
07 ASSUMED EXISTING STEEL STRUCTURE HSS BEAMS AT COVERED OUTDOOR AREA. CONTRACTOR TO FIELD VERIFY.
08 ASSUMED EXISTING STEEL HSS BEAMS AT ROOF RIDGE AT COVERED OUTDOOR AREA. CONTRACTOR TO FIELD VERIFY.
09 ASSUMED EXISTING STEEL HSS POST UP AT EXISTING HSS BEAMS AT COVERED OUTDOOR AREA. CONTRACTOR TO FIELD
VERIFY.
10 EXISTING FRAMING.
12 EXISTING 72" +/- DEEP FLAT WOOD ROOF TRUSSES AT 16" OC.
13 EXISTING PREFABRICATED WOOD ROOF TRUSSES AT 16" OC.
14 EXISTING 2X12 WOOD RAFTERS AT 16" OC.
15 NEW CFMF BULKHEAD SUSPENDED FROM EXISTING STEEL BEAMS. DESIGN OF BULKHEAD BY CFMF SPECIALTY ENGINEER.
18 NEW KITCHEN HOOD WITH A MAXIMUM WEIGHT OF 1000 LBS WITH 8 ATTACHMENT POINTS. PROVIDE BLOCKING BETWEEN EXIST TRUSSES AT ATTACHMENT POINTS. REFER TO TYPICAL KITCHEN HOOD SUPPORT DETAILS ON S5.02.
25 PREFABRICATED OUTLOOKER TRUSSES AT 24" OC MAX.
26 NEW OPENING FOR NEW VENTILATOR.
27 CUPOLA, REFER TO ARCHITECTURAL DRAWINGS. PREFABRICATED TRUSS FABRICATOR TO DESIGN ROOF TRUSSES TO
SUPPORT NEW CUPOLA.
28 2x8 AT 16" OC.
30 (2) 1 3/4"x12 1/4" LVL.
31 (2) - 2x8.
32 FRAME OUT OPENING WITH (2) 2x8.
33 NEW OAP-1, AHU-1, & AHU-2 UNITS LOCATED ON NEW MECHANICAL PLATFORM. COORDINATE WITH MEP AND ARCH DWGS.
35 ADD 2X4 BLOCKING BETWEEN RAFTERS OR TRUSS TOP CHORD ALONG RTU CURB.
36 REPLACE EXISTING WOOD BEAM WITH NEW STEEL BEAM. SHORE EXISTING CONSTRUCTION AS REQUIRED.
40 FRAME NEW BEAM TO EXISTING WITH STANDARD 2 BOLT SHEAR PLATE CONN
42 HSS 4X4X1/4 FOR TRUSS SUPPORT. WELD ALL AROUND TO COL FLANGE WITH 1/4" FILLETS
43 2X12 AT 16" O/C
44 SISTER EACH TRUSS TOP CHORD UNDER MECHANICAL UNITS WITH A CONTINUOUS 2X12 FULL LENGTH BETWEEN BEARING POINTS. SISTER EACH OF THE TRUSS VERTICALS OVER THE BEAMS WITH A NEW 2X4 TIGHT TO THE BOTTOM OF THE 2X12 AND
THE BOTTOM PLATE.
1/8" = 1'-0"
ROOF FRAMING PLAN
1/8" = 1'-0"
MECHANICAL PLATFORM
Lic. No. 017580
JOHN H. HANCOCK
REVISIONS
# DATE DESCRIPTION
1 05/09/2023 ADDENDUM 1
30.5
EXIST BEAM - REF
PLAN
OVERBUILT ROOF
TRUSS - REF PLAN
AND TYP DETAILS
NEW ROOF TRUSS
BTWN EXIST
RAFTERS - REF PLAN
CONT 2x6 NAILER
ATTACHED TO STEEL
BEAM W/ (2) 3/16" DIA PAF
AT 6" O/C EA SIDE OF BM
WEB
BEAM - REF PLAN
PRECAST CONC
CAP - REF ARCH
DWGS
BRICK VENEER -
REF ARCH
DWGS
8" CMU GROUTED
SOLID W/ #4 AT
40" OC
CONT CMU BOND
BEAM W/ (2) #4
EXIST WALL AND
FTG TO REMAIN
2x4 NAILER PL
ATTACHED TO STEEL
BEAM W/(2) 3/16" PAF IN
EA SECTION
ALUMINUM CLIPS BY PATIO
ENCLOSURE FABRICATOR
ON BOTH SIDES OF POST
W/ 1/2"Ø STAINLESS STEEL
THREADED ROD W/ HILTI
HIT-HY 200 (2 1/2" EMBED
INTO CONC SOG)
ALUMINUM POST
FOR VINYL PATIO
ENCLOSURE - REF
ARCH DWGS
VINYL PATIO
ENCLOSURE - REF
ARCH DWGS
2x4 BLOCKING BTWN
TRUSSES AT
ALUMINUM POSTS
1/2"Ø STAINLESS STEEL
THRU BOLT IN LONG-
SLOTTED VERT HOLE IN
ALUMINUM POST TO
ALLOW FOR VERT SLIP
HOLD-DOWNS BY
TRUSS MFR (TYP)
EXIST ROOF RAFTER TO
REMAIN, TRIM END OF
ROOF RAFTER AS NEEDED
FOR NEW CONSTRUCTION
BUT MAINTAIN FULL
BEARING
NEW WINDOW
ASSEMBLY - REF
ARCH DWGS
WALL FTG - REF
PLAN AND SCHED
EXIST PAVERS
ON EXIST SLAB-
ON-GRADE
TOP OF
MASONRY - REF
ARCH DWGS
BLOCKING PANEL
B/W ROOF TRUSSES -
REF TYP DETAILS
ROOF SHEATHING -
REF GENERAL
NOTES AND TYP
DETAILS
EXIST ROOF SHEATHING,
TO REMAIN
ADJUSTABLE FRAMING
CLIPS AT 12" OC TO ATTACH
NEW ROOF SHEATHING TO
EXISTING ROOF SHEATHING
COORDINATE W/ ARCH DWGS
19'-11" ±
/8
1:6
1'-4"
2X BLOCKING B/W
ROOF TRUSSES
AT TOP AND
BOTTOM CHORD
TOP OF MAS , REF
ARCH
TRUSS BRG
=9'-11 1/2"
REF ARCH
H2.5A
HURRICANE
TIE
2X4 BET TRUSSES
ROOF TRUSSES-
SPACE TO FALL
BTWN EXIST
RAFTER ON
LINE 3
CONT 2X6 OVER ROOF
SHEATHING NAIL TO EA
RAFTER W/ 2 12d NAILS
PROVIDE A HORIZ ROW OF 2" DIA
VENTILATION HOLES AT 4" OC IN THE
SHEATHING W/ BUG SCREENING
20.5
EXIST HSS BEAM -
REF PLAN
2x PLATES BET
EXIST STUDS
FOR DETAILS
NOT NOTED REF
SECTION 1/S3.01
12"X12" CMU PIER GROUTED
SOLID W/ (4) #4 VERT REINF
#2 SMOOTH TIES AT EA CMU
COURSE
ATTACHMENT OF ARCH COL
TO CMU PIER PER MFR'S
RECOMMENDATIONS
EXISTING WALL AND
ROOF STRUCTURE
TO REMAIN
REF ARCH
COORDINATE W/ ARCH DWGS
11'-11" ±
1:6
/8
TRUSS - REF PLAN, SPACE TRUSSES
TO FALL BETWEEN EXISTING WALL
FRAMING ON LINE 2
WALL SHEATHING -
ATTACH TO EA STUD AND
TRUSS VERT NOTCH AT EA
TRUSS CHORD
0'-3"
0'-3" CLR TYP
2X4'S BET TRUSS
TO CHORDS
EXIST 6" CFMF
M
IN
1/2" DIA THREADED
STUD - 2 FOR EA
SEGMENT OF
BLOCKING
ALIGN INSIDE
FACE OF TRUSS
VERT W/ FACE OF
EXIST CFMF
TRUSS VERT
SHALL BE A 2X6
ALIGN INSIDE FACE OF
TRUSS VERT W/ FACE
OF EXIST CFMF
TRUSS TOP
CHORD BEYOND
2X4 FRAMING AT 16"
O/C TO SUPPORT THE
AIR BARRIER REF
A5/S6.03
D
OUTLOOKER TRUSS -
REF PLAN
ROOF TRUSS - REF
PLAN
CONT 2x6 NAILER
ATTACHED TO
STEEL BEAM W/ (2)
3/16" DIA PAF AT 6"
O/C EA SIDE OF BM
WEB
BEAM - REF PLAN
GRID
D E
P T
H V
A R
IE
S
ROOF SHEATHING -
REF GENERAL NOTES
HOLD-DOWNS
BY TRUSS MFR
2X4 BET TRUSSES
T&B
WALL SHEATHING
1'-2 1/4"
ASSUMED WOOD
RAFTER - FIELD
VERIFY
ASSUMED STEEL
BEAM - FIELD
VERIFY
2x6 OUTLOOKERS
AT 24" OC
ROOF TRUSS - REF
PLAN
ROOF TRUSS WITH
DROPPED TOP
CHORD - REF PLAN
NEW ROOF
SHEATHING - REF
GENERAL NOTES
AND TYP DETAILS
EXIST ROOF
SHEATHING
ADJUSTABLE FRAMING
CLIPS AT 12" OC TO ATTACH
NEW ROOF SHEATHING TO
EXISTING ROOF SHEATHING
FRAMING CLIP TO
ATTACH OUTLOOKER
TO 2X6
2x6 BLOCKING BET
EA TRUSS
CONT 2X6 OVER ROOF
SHEATHING NAIL TO
EA RAFTER WITH 2
12d NAILS
MOVE CLIP UP TO BE
AT TOP OF NEW 2X6
ROOF SHEATHING -
REF GENERAL
NOTES AND TYP
DETAILS
EXIST RAFTER TO
REMAIN, TRIM END AS
NEEDED FOR NEW
CONSTRUCTION
EXIST ROOF
SHEATHING, CUT
AS NEEDED FOR
NEW FRAMING
EXIST DBL TOP PL
W/ HOOKED BOLTS
TO REMAIN
ROOF TRUSS -
SPACE TO FALL
BTWN EXIST
RAFTERS
EXIST CMU WALL
ADJUSTABLE FRAMING
CLIPS AT 12" OC TO
ATTACH NEW ROOF
SHEATHING TO EXISTING
ROOF SHEATHING
H2.5A
HURRICANE TIE
ROOF SHEATHING
BTWN EXIST
REFERS
8d NAIL AT 6" O/C
TYP
2X4 BTWN EXIST
RAFTERS T&B
CONT 2X6 OVER ROOF
SHEATHING NAIL TO EA
RAFTER W/ 2 12d NAILS
2X6 BET EXIST
RAFTER
PROVIDE A HORIZ ROW
OF 2" DIA VENTILATION
HOLES AT 4" OC IN THE
SHEATHING W/ BUG
SCREENING
NEW SLAB-ON-
GRADE - REF PLAN
8" CMU W/
#5 AT 40" OC GROUT
SOLID BELOW
GRADE
WALL FTG - REF
PLAN AND SCHED
BRICK PAVERS
ON CONC SLAB-
ON-GRADE - REF
CIVIL DWGS
CURTAIN WALL
SYSTEM - REF
ARCH DWGS
#4 CONT
#4 AT 12" O/C
WITH STD 90 DEG
HK
2'-0"
WALL FTG - REF
PLAN AND SCHED
EXT SLAB-ON-GRADE -
REF CIVIL DWGS
BRICK PAVERS - REF
ARCH DWGS
8" CMU WALL W/ #5 AT
32" OC
REF CIVIL DWGS
MASONRY VENEER -
REF ARCH DWGS
1'-4"
4" CMU BELOW
GRADE - GROUT
SOLID
MORTAR COLLAR
JT SOLID
WALL FTG - REF
PLAN AND SCHED
10" CMU W/ #5 AT
32" OC
WALL BEYOND -
REF ARCH DWGS
NEW SOG - REF
PLAN
NEW BRICK PAVERS
ON NEW SOG AS
REQUIRED FOR NEW
CONSTRUCTION
2'-0"
#4 CONT
#4 AT 12" O/C
WITH STD 90 DEG
HK
FOR DETAILS NOT NOTED
REF 6/S3.02
C O M M O
N W
EA
LTH OF
V I
R G I N I A
P R O F
E
SS IONAL EN
G
IN
E E R
Structural Engineers 1519 Summit Ave., Suite 101
Richmond, VA 23230
804.346.3935 - lynchmykins.com
All ideas, designs, arrangements and plans indicated or represented by this drawing are property of ENTEROS DESIGN, PC; created, evolved and developed for the sole use of this project. These ideas, design arrangements and/or plans shall not be used by or disclosed to any person, firm or corporation for any purpose without written permission from ENTEROS DESIGN, PC. Written dimensions on these drawings shall have precedence over scaled dimensions. Contractors shall verify and be responsible for all dimensions and conditions on the job. The Architect must be notified of any variations from the dimensions and conditions shown on these drawings.
© 2022 ENTEROS DESIGN, PC
7 NORTH 25TH STREET
RICHMOND, VA 23223
804.861.1200 P
4/14/23
W A
TE
R
S
TR
EE
T
R E
ST
A U
R A
N T
Y O
R K
TO
W
N V
IR
G
IN
IA
S3.01
PROJ. NO.: 211005
DATE: 04/14/23
DRAWN BY: BRW
SECTIONS
CONSTRUCTION
DOCUMENTS
3/4" = 1'-0"
SECTION
1 3/4" = 1'-0"
SECTION
2 3/4" = 1'-0"
SECTION
3/4" = 1'-0"
SECTION
4 3/4" = 1'-0"
SECTION
5 3/4" = 1'-0"
SECTION
6 3/4" = 1'-0"
SECTION
7 3/4" = 1'-0"
SECTION
Lic. No. 017580
JOHN H. HANCOCK
REVISIONS
# DATE DESCRIPTION
1 2
8" CFMF JOISTS AT 24" OC
MAX BY SPECIALTY
ENGINEER LOCATE BET
EXISTING WALL STUDS
6" CFMF STUDS AT 24" OC
BY SPECIALTY ENGINEER
EXIST HSS
BEAM
CONT 6" CFMF TRACK BY
SPECIALTY ENGINEER
CFMF CLIP AT EA JOIST
BY SPECIALTY ENGINEER
CONT 8" CFMF TRACK BY
SPECIALTY ENGINEER
CFMF CLIP
ATTACHED TO HSS
BEAM W/ PAF
FOR DETAILS NOT
NOTED REF
SECTION 8/S3.01
CONT 6" CFMF
TRACK ATTACHED
TO CONC SLAB W/
PAF AT EA STUD
EXIST FDN WALL
AND FTG TO
REMAIN. DEMO TOP
COURSE FOR NEW
PAVERS ON CONC
BASE - REF ARCH
DWGS
EXISTING CFMF WALL
TO REMAIN, MODIFY AS
REQUIRED FOR NEW
CONSTRUCTION - REF
ARCH DWGS
ROOF SHEATHING, REF
GENERAL NOTES
JOIST BEARS ON HSS
8" CFMF STUD BET
EA RAFTER
WALL SHEATHING
4" CFMF BY SPECIALTY
ENGINEER
N.1N.9
OVERBUILT TRUSSES OR
STICK FRAMING
AT 24" OC - REFER TO
TYPICAL BUILT-UP ROOF
FRAMING DETAILS
BEAM - REF PLAN
WOOD ROOF
TRUSSES - REF
PLAN
1:11:
ROOF SHEATHING -
REF GENERAL NOTES
ADJUSTABLE FRAMING
CLIPS AT 12" OC TO ATTACH
NEW ROOF SHEATHING
HOLD-DOWNS BY
TRUSS MFR (TYP)
WALL SHEATHING -
REF GENERAL NOTES
COORDINATE W/ ARCH DWGS
14'-5" ±
/8
CONT 2X4
BLOCKING B/W
ROOF TRUSSES
BLOCKING PANEL B/W
ROOF TRUSSES - REF
TYP DETAILS
2X6 BTWN EA TRUSS-
TAPPER TOP TO MATCH
ROOF SLOPE
CONT 2X4 TAPER EDGE
TO MATCH ROOF SLOPE
NAIL EA TRUSS OR
RAFTER WITH 2 12d
NAILS
TRUSS BRG ELEV=
9'-11"
CONT 2X4 T&B
2X4 AT 16" O/C
BUILT UP ROOF
FRAMING
2X4 BET EA
OUTLOOKER
2X4 OUTLOOKER AT
16" O/C
ELEV VARIES
CONT 2X4
1'-2 3/8"
CONT 2X6 - ATTACH
TO BM W/ (2) 3/16"
DIA PAF AT 6" O/C
EA SIDE OF BM WEB
0'-2 1/4"
9.1 11.1 12.4
BEAM - REF PLAN
WOOD TRUSS -
REF PLAN
BEAM - REF PLAN
GABLE END WOOD
ROOF TRUSS - REF
PLAN
OVERBUILT TRUSS AT 24" OC,
REFER TO TYPICAL BUILT-UP
ROOF FRAMING DETAILS
2x6 BRACES AT
24" OC
ROOF SHEATHING -
REF GENERAL NOTES
COORDINATE W/ ARCH DWGS
7'-2 1/2" ±
COORDINATE W/ ARCH DWGS
14'-5" ±
2X6 BLOCKING BTWN WOOD
TRUSSES AT RIDGE AND AT EA OVER
BUILT TRUSS
EXISTING
SLOPED W BEAM
INFILL OPENING
W/ CFMF STUDS
AND BRICK
VENEER - REF
ARCH DWGS
EXISTING
HSS BEAM
1:11:
2X4 BTWN EA TRUSS- TAPER
TOP TO MATCH ROOF SLOPE
REF ARCH
TRUSS BRG
ELEV=9'-11" H2.5A HURRICANE
TIE
DESIGN TRUSS TO
TRANSFER 250 PLF
FROM TOP CHORD TO
BOT
1" CLR BTWN
TRUSS AND
BRICK
ELEV VARIES
3 16d NAILS AT
EA END
0'-2 1/4"
WALL SHEATHING
CONT 2X6 - ATTACH
TO BM W/ (2) 3/16"
DIA PAF AT 6" O/C EA
SIDE OF BM WEB
2X4 AT 16" O/C
2X6 AT VERT
2X4 AT EA
VERT
CPMT 2X4
ROOF SHEATHING
2X4 BET EA
OUTLOOKER
CONT 2X4 TAPER EDGE
TO MATCH ROOF
SLOPE NAIL EA TRUSS
OR RAFTER W/ 2 12d
NAILS
CONT 2X4
NOTCH WALL
SHEATHING AT
OUTLOOKER
PROVIDE A HORIZ ROW
OF 2" DIA VENTILATION
HOLES AT 4" O/C IN
THE SHEATHING W/
BUG SCREENING
THREADED ROD,
CONNECTION BY
CUPOLA MANUF TO
STRUCTURE AT BASE
2X6 BTWN TRUSSES
UNDER ALL CUPOLA
WALLS
CUPOLA - REF ARCH
DWGS
ROOF SHEATHING -
REF GEN NOTES
ROOF TRUSSES - REF
PLAN
2x4 WOOD FRAMING
ATTACHED TO ROOF
TRUSSES AND BLOCKING
WITH SIMPSON SA STRAP
CONNECTOR AT EACH
CUPOLA CORNER
THREADED ROD
2x BLOCKING
BTWN TRUSSES
WASHER PL1/4X3X3
A
A
DETAIL A-A
DESIGN TRUSS FOR A
CONCENTRATED
LOAD OF 1500Lbs AT
EA CUPOLA CORNER
SUPPORT IN
ADDITION TO ALL
OTHER LOADS
1 1
DBL TOP PL
C O M M O
N W
EA
LTH OF
V I
R G I N I A
P R O F
E
SS IONAL EN
G
IN
E E R
Structural Engineers 1519 Summit Ave., Suite 101
Richmond, VA 23230
804.346.3935 - lynchmykins.com
All ideas, designs, arrangements and plans indicated or represented by this drawing are property of ENTEROS DESIGN, PC; created, evolved and developed for the sole use of this project. These ideas, design arrangements and/or plans shall not be used by or disclosed to any person, firm or corporation for any purpose without written permission from ENTEROS DESIGN, PC. Written dimensions on these drawings shall have precedence over scaled dimensions. Contractors shall verify and be responsible for all dimensions and conditions on the job. The Architect must be notified of any variations from the dimensions and conditions shown on these drawings.
© 2022 ENTEROS DESIGN, PC
7 NORTH 25TH STREET
RICHMOND, VA 23223
804.861.1200 P
4/14/23
W A
TE
R
S
TR
EE
T
R E
ST
A U
R A
N T
Y O
R K
TO
W
N V
IR
G
IN
IA
S3.02
PROJ. NO.: 211005
DATE: 04/14/23
DRAWN BY: BRW
SECTIONS
CONSTRUCTION
DOCUMENTS
3/4" = 1'-0"
SECTION
3/4" = 1'-0"
SECTION
3/4" = 1'-0"
SECTION
3/4" = 1'-0"
SECTION
Lic. No. 017580
JOHN H. HANCOCK
REVISIONS
# DATE DESCRIPTION
11.1
BRICK VENEER -
REF ARCH
DWGS
8" CMU GROUTED
SOLID W/ #4 AT
40" OC
WALL…