R-7296 Addendum 1 with Drawings.pdf

PDF 22 MB Posted

Attached to
R-7296 REBID TID Radio & Asset Services Building
Solicitation number
PW-26-754
Issued by
Los Angeles County, California

About this file

This is Bid Addendum No. 1 issued by the City of Long Beach Department of Public Works for Plans and Specifications No. R-7296 concerning the TID Radio & Asset Services Building. The addendum, dated July 6, 2026, replaces all previously posted drawings in their entirety with an updated set titled "B-4854 TID Bldg. 100% Drawings 7.6.26." The project involves office and warehouse improvements to a 10,772 square-foot, one-story facility classified as Business (B) and Storage (S-1) occupancy. The scope of work encompasses asbestos abatement, ADA-compliant restrooms, millwork, HVAC ductwork, new roof installation, electrical and lighting systems, plumbing, interior finishes, chain link enclosures, rollup door, electric vehicle charging infrastructure, parking stall improvements, and vehicle exhaust control systems. The updated drawings include 68 total sheets covering architectural, mechanical, and electrical specifications, including site plans, demolition plans, partition plans, roof plans, reflected ceiling plans, exterior elevations, building sections, finish plans, restroom details, and door schedules. A mandatory pre-bid conference was scheduled for July 9, 2026 at 11:00 a.m. via Microsoft Teams, with a mandatory job-site walkthrough from 1:00 p.m. to 2:30 p.m. at 2961 Redondo Avenue. Bids were due August 6, 2026 at 11:00 a.m., and work must be completed within 243 calendar days of notice to proceed.

The project is subject to Title 24, Part 2 of the California Code of Regulations regarding disabled access and adaptability requirements, as well as the 2022 California Building Code, California Energy Code, California Fire Code, and California Green Building Standards Code. The Long Beach Small Business Enterprise Program applies with a 10% combined goal for SBE/VSBE/LSBE participation. A Citywide Project Labor Agreement with the Los Angeles/Orange Counties Building and Construction Trades Council establishes prevailing wage requirements and local hiring goals of 40% calculated on total hours worked, plus a 10% goal for transitional workers and veterans. Bidders must hold a valid California Class B contractor license and be registered with the Department of Industrial Relations, with bid security of 10% required. Certified payroll records must be submitted electronically in compliance with prevailing wage rates determined by the California Department of Industrial Relations. Workers' compensation insurance, commercial general liability insurance with minimum limits, and pollution/environmental impairment liability coverage are required.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

7/6/2026

July 6, 2026

BID ADDENDUM NO. 1

PLANS AND SPECIFICATIONS NO. R-7296

TID RADIO & ASSET SERVICES BUILDING

NOTICE TO HOLDERS OF PLANS AND SPECIFICATIONS

Please note the following changes, clarifications, and additions:

1. The drawings posted in LB Buys are replaced in their entirety with an updated set of drawings:

“B-4854 TID Bldg. 100% Drawings 7.6.26”

PREPARED BY: Nancy Villaseñor

ACKNOWLEDGED BY: ___________________________________________

Company Name

Print Name Title

Signature Date

Department of Public Works 411 West Ocean Boulevard, 5th Floor Long Beach, CA 90802

(562) 570-6383

THIS PROJECT IS SUBJECT TO TITLE 24, PART 2, OF THE CALIFORNIA CODE

OF REGULATIONS, SECTIONS 1.8.2.1.2, 1.9.1 AND 1103B, THE STATE’S

DISABLED ACCESS AND ADAPTABILITY REQUIREMENTS. THE DESIGN

PROFESSIONAL OF RECORD SHALL SIGN A STATEMENT ON THE PLANS TO

THE EFFECT:

"I CERTIFY THAT THE PRIMARY PATH OF TRAVEL TO THE SPECIFIC AREA OF

ALTERATION, STRUCTURAL REPAIR OR ADDITION FROM THE PUBLIC WAY

OR ACCESSIBLE PARKING SPACE AS INDICATED ON THE PLANS DOES NOT

INCLUDE STEPS OR A SLOPE EXCEEDING 1:20 EXCEPT WHERE ACCESS IS

PROVIDED BY A RAMP WITH 1:12 MAXIMUM SLOPE, ACCESSIBLE ELEVATOR

OR OTHERWISE GRANTED BY AN UNREASONABLE HARDSHIP EXEMPTION. I

UNDERSTAND THAT IF THE PRIMARY PATH OF TRAVEL IS FOUND NOT TO

BE AS INDICATED, SIGNIFICANT DELAYS MAY RESULT.

FURTHERMORE, I CERTIFY THAT THESE PLANS WERE PREPARED UNDER MY

DIRECT SUPERVISION AND THAT THE AREA OF SPECIFIC ALTERATION,

STRUCTURAL REPAIR OR ADDITION, INCLUDING A PRIMARY ENTRANCE TO

THE EXISTING BUILDING AND, WHEN APPLICABLE, SANITATION FACILITIES,

DRINKING FOUNTAINS, SIGNS AND PUBLIC TELEPHONES SERVING THE

AREA COMPLIES WITH CURRENT CA TITLE 24 ACCESSIBILITY

REQUIREMENTS."

SIGNATURE TITLE

PRINT DATE

SHEET INDEX

A-0.00 COVER SHEET

GENERAL

SHEET DESCRIPTION IS

SU

E

FO

R

0%

A-0.11 GENERAL NOTES

A-0.12 GENERAL NOTES

A-0.13 GENERAL NOTES

A-0.14 2022 CBC CHAPTER 11B

A-0.21 2022 CALGREEN NON-RESIDENTIAL

A-0.22 2022 CALGREEN NON-RESIDENTIAL

A-0.23 2022 CALGREEN NON-RESIDENTIAL

A-0.24 2022 CALGREEN NON-RESIDENTIAL

A-0.61 EGRESS PLAN

AD-1.00 DEMOLITION SITE PLAN

ARCHITECTURAL DEMOLITION

AD-1.01 DEMOLITION PARTITION PLAN

AD-1.11 DEMOLITION ROOF PLAN

A-1.00 SITE PLAN

ARCHITECTURAL

A-1.01 PARTITION PLAN

A-1.11 ROOF PLAN

A-2.01 REFLECTED CEILING PLAN

A-3.01

EXTERIOR ELEVATIONSA-4.01

BUILDING SECTIONSA-5.01

FINISH PLAN - FLOOR

A-7.01 ENLARGED RESTROOM PLAN

D-1.01 DETAILS - WALL

D-8.01 DETAILS - DOOR

D-2.01 DETAILS - CEILING

A-8.01 DOOR SCHEDULE

AD-2.01 DEMOLITION REFLECTED CEILING PLAN

MECHANICAL

ELECTRICAL

TOTAL SHEETS: 68

M-0.01 GENERAL NOTES, LEGEND, CODES AND SHEET INDEX

M-0.02

MECHANICAL DEMO PLAN - LEVEL 1

MD-2.02 MECHANICAL DEMO PLAN - ROOF LEVEL

M-2.01 MECHANICAL PLAN - LEVEL 1

MD-2.01

MECHANICAL SCHEDULES

M-2.02 MECHANICAL PLAN - ROOF LEVEL

M-6.01 MECHANICAL DETAILS

E-0.01 ELECTRICAL GENERAL NOTES AND SHEET INDEX

E-0.02

ELECTRICAL SINGLE LINE DIAGRAM

ED-2.01 ELECTRICAL DEMOLITION POWER PLAN

ED-2.02 ELECTRICAL DEMOLITION LIGHTING PLAN

ELECTRICAL SYMBOLS LIST AND ABBREVIATIONS

E-1.01 ELECTRICAL SITE REMODEL POWER PLAN

E-2.01 ELECTRICAL REMODEL POWER PLAN

DETAILS - ROOFD-1.11

THE CONTRACTOR SHALL CONFORM TO ALL CODES, ORDINANCES, ETC.

WHICH HAVE JURISDICTION OVER THE WORK. THE CONTRACTOR SHALL

RETAIN RESPONSIBILITY FOR COMPLIANCE WITH LATEST REVISIONS OF ALL

OTHER APPLICABLE CODES AND ORDINANCES INCLUDING THE FOLLOWING:

CALIFORNIA CODE OF REGULATIONS:

TITLE 19 - CALIFORNIA CODE OF REGULATIONS

TITLE 24 - BUILDING STANDARDS CODE:

2022 CALIFORNIA ADMINISTRATIVE CODE

2022 CALIFORNIA ENERGY CODE - TITLE 24

2022 CALIFORNIA EXISTING BUILDING CODE

2022 CALIFORNIA BUILDING CODE (CBC)

2022 CALIFORNIA ELECTRICAL CODE (CEC)

2022 CALIFORNIA MECHANICAL CODE (CMC)

2022 CALIFORNIA PLUMBING CODE (CPC)

2022 CALIFORNIA FIRE CODE (CFC)

2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CGBSC)

LONG BEACH MUNICIPAL CODE:

TITLE 18 - LONG BEACH BUILDING STANDARDS CODE

TITLE 21 - ZONING

OWNER

CITY OF LONG BEACH

411 W. OCEAN BLVD

LONG BEACH, CA 90802

CONTACT: NANCY VILLASENOR

PHONE: 562.570.4634

EMAIL: NANCY.VILLASENOR@LONGBEACH.GOV

ARCHITECT

KARDENT

11 GOLDEN SHORE, SUITE 540

LONG BEACH, CA 90802

CONTACT: ERICA BOARD

PHONE: 562-436-9900

EMAIL: EBOARD@KARDENTDESIGN.COM

(E) EXISTING

(N) NEW

L ANGLE

& AND

@ AT

# POUND OR NUMBER

CL CENTERLINE

DIA DIAMETER OR ROUND

ACOUS. ACOUSTICAL

ACT ACOUSTICAL CEILING TILE

A.D. AREA DRAIN

ARCH. ARCHITECTURAL

AES.ST. AESTHETIC STEEL

AGG. AGGREGATE

ALUM. ALUMINUM

ANO. ANODIZED

APPROX. APPROXIMATE

ARCH. ARCHITECTURAL

ASPH. ASPHALT

BD. BOARD

BITUM. BITUMINOUS

BLDG. BUILDING

BLK. BLOCK

BLKG. BLOCKING

BM. BEAM

BOT. BOTTOM

CAB. CABINET

C.B. CATCH BASIN

CEM. CEMENT

CER. CERAMIC

C.G. CORNER GUARD

C.I. CAST IRON

CLG. CEILING

CLKG. CAULKING

CLO. CLOSET

CLR. CLEAR

CNTR. CENTER

C.O. CASED OPENING

COL. COLUMN

CONC. CONCRETE

CONN. CONNECTION

CONSTR. CONSTRUCTION

CONT. CONTINUOUS

CORR. CORRIDOR

CP COMMON PATH

CTSK. COUNTERSUNK

CTR. COUNTER

DBL. DOUBLE

DEPT. DEPARTMENT

DET. DETAIL

D.F. DRINKING FOUNTAIN

DIA. DIAMETER

DIM. DIMENSION

DISP. DISPENSER

DN. DOWN

D.O. DOOR OPENING

DR. DOOR

D.S. DOWNSPOUT

D.S.P. DRY STANDPIPE

DWG. DRAWING

DWR. DRAWER

E EXISTING

EA. EACH

E.D.F. ELECTRICAL DRINKING FOUNTAIN

E.J. EXPANSION JOINT

EL. ELEVATION

ELEC. ELECTRICAL

ELEV. ELEVATOR

EMER. EMERGENCY

ENCL. ENCLOSURE

E.P. ELECTRICAL PANEL BOARD

EQ. EQUAL

EQPT. EQUIPMENT

E.W.C. ELECTRICAL WATER COOLER

EXST. EXISTING

EXP. EXPANSION

EXPO. EXPOSED

EXT. EXTERIOR

F.A. FIRE ALARM

F.B. FLAT BAR

F.D. FLOOR DRAIN

FDN. FOUNDATION

F.A. FIRE EXTINGUISHER

F.A.C. FIRE EXTINGUISHER CABINET

F.B. FINISH FLOOR

FE FIRE EXTINGUISHER

F.H.C. FIRE HOSE CABINET

FIN. FINISH

FL. FLOOR

FLASH. FLASHING

FLUOR. FLUORESCENT

F.O.C. FACE OF CONCRETE

F.O.F. FACE OF MASONRY

F.O.S. FACE OF STUD

FP FIRE ALARM PULL

FPRF. FIREPROOF

F.R. FIRE-RATED

F.S. FULL SIZE

FT. FOOT OR FEET

FTG. FOOTING

FURR. FURRING

FUT. FUTURE

GA. GAUGE

GALV. GALVANIZED

G.B. GRAB BAR

G.C. GENERAL CONTRACTOR

GFA GROSS FLOOR AREA

G.I.S.M GALVANIZED IRON SHEET METAL

GL. GLASS

GND. GROUND

GR. GRADE

GYP. GYPSUM

H.B. HOSE BIB

H.C. HOLLOW CORE

HDWD. HARDWOOD

HDWE. HARDWARE

H.M. HOLLOW METAL

HORIZ. HORIZONTAL

HR. HOUR

H. HEIGHT

ID. INSIDE DIAMETER

IN. INCH OR INCHES

INSUL. INSULATION

INT. INTERIOR

JAN. JANITOR

JT. JOINT

KIT. KITCHEN

LAB. LABORATORY

LAM. LAMINATE

LAV. LAVATORY

LKR. LOCKER

LT. LIGHT

MAX. MAXIMUM

M.D. MEDICINE CABINET

MECH. MECHANICAL

MEMB. MEMBRANE

MET. METAL

MFR. MANUFACTURER

MH. MANHOLE

MIN. MINIMUM OR MINUTES

MIR. MIRROR

MISC. MISCELLANEOUS

M.O. MASONRY OPENING

MTD MOUNTED

MTL MATERIAL

MUL. MULLION

N NEW

NA NOT APPLICABLE

N.I.C. NOT IN CONTRACT

NO. NUMBER

NOM. NOMINAL

N.R. NOT RATED

N.T.S. NOT TO SCALE

O.A. OVERALL

OBS. OBSCURE

O.C. ON CENTER

O.D. OUTSIDE DIAMETER

OFF. OFFICE

OPNG. OPENING

OPP. OPPOSITE

O.L.F. OCCUPANT LOAD FACTOR

P.F. PRE-FINISHED

P.LAM. PLASTIC LAMINATE

P.T.D. PAPER TOWEL DISPENSER

COMBINATION

P.T.D./R PAPER TOWEL DISPENSER

& RECEPTACLE

PL. PLATE

PLAS. PLASTER

PLYWD. PLYWOOD

PR. PAIR

PRCST. PRE-CAST

PT. POINT OR PAINTED

Q.T. QUARRY TILE

R. RISER

RAD. RADIUS

RCP REFLECTED CEILING PLAN

R.D. ROOF DRAIN

REF. REFERENCE

REFR. REFRIGERATOR

RGTR. REGISTER

REINF. REINFORCED

REQ. REQUIRED

RESIL. RESILIENT

RM. ROOM

R.O. ROUGH OPENING

RWD. REDWOOD

R.W.L. RAIN WATER LEADER

S.C. SOLID CORE

S.C.D. SEAT COVER DISPENSER

SCHED. SCHEDULE

S.A. SOAP DISPENSER

SECT. SECTION

SH. SHELL

SHR. SHOWER

SHT. SHEET

SIM. SIMILAR

S.N.D. SANITARY NAPKIN DISPENSER

S.N.R. SANITARY NAPKIN RECEPTACLE

SPEC. SPECIFICATION

SQ. FT. SQUARE FEET

S.ST. STAINLESS STEEL

S.SK. SERVICE SINK

ST. STAINED

STA. STATION

STD. STANDARD

STL. STEEL

STOR. STORAGE

STRL. STRUCTURAL

SUSP. SUSPENDED

SYM. SYMMETRICAL

T. TEMPERED

TD TRAVEL DISTANCE

TRD. THREAD

T.B. TOWEL BAR

T.C. TOP OF CURB

TEL. TELEPHONE

TER. TERRAZZO

T.&G. TONGUE AND GROOVE

THK. THICK

T.O.C. TOP OF CANOPY

T.O.M.S. TOP OF MECHANICAL SCREEN

T.O.P. TOP OF PARAPET

T.O.S. TOP OF SURFACE

T.O.W. TOP OF WALL

T.P. TOP OF PAVEMENT

T.P.D. TOILET PAPER DISPENSER

T.V. TELEVISION

TYP. TYPICAL

U.N.O. UNLESS NOTED OTHERWISE

V.P. VISION PANEL

VERT. VERTICAL

VEST. VESTIBULE

W/ WITH

W.C. WATER CLOSET

WD. WOOD

W/O WITHOUT

W.P. WATERPROOF

WT. WEIGHT

MEP ENGINEER

STRUCTURAL ENGINEER

PBS ENGINEERS

279 E ARROW HIGHWAY, SUITE 201

SAN DIMAS, CA 91773

CONTACT: LOUIS (LOU) R. PEREZ

PHONE: 626.691.3090

EMAIL: LPEREZ@PBSENGINEERS.COM

INSIGHT STRUCTURAL ENGINEERS

855 NORTH DOUGLAS ST, FIRST FLOOR

EL SEGUNDO, CA 90245

CONTACT: VANESSA L. CHOW

PHONE: 310.640.0123 X103

EMAIL: VCHOW@INSIGHT-SE.COM

PROJECT TEAM

ABBREVIATIONS SCOPE OF WORK

USE OF BUILDING: B; S-1 - EXISTING NO CHANGE

TYPE OF CONSTRUCTION: III-B

NUMBER OF STORIES: 1 STORY - EXISTING NO CHANGE

SQUARE FOOTAGE: 10,772 - EXISTING NO CHANGE

FULLY FIRE SPRINKLERED: YES - EXISTING

FIRE ALARM SYSTEM: YES - EXISTING

OCCUPANCY GROUP: B- BUSINESS (OFFICE USE); S-1 - EXISTING, NO CHANGE

OCCUPANCY LOAD: 80 OCCUPANTS

EXITS REQUIRED: 2

EXITS PROVIDED: 4

TRAVEL DISTANCE: 176'-5"<300' MAX FULLY SPRINKLERED

COMMON PATH OF TRAVEL: 57'-10"<100' MAX FULLY SPRINKLERED

ZONING CLASSIFICATION: SP-3-IG

PARKING CALCULATION:

WAREHOUSE 1 PER 1,000 GFA (OFFICE AREA GREATER THAN 25% IS CALCULATED

SEPARATELY)

B 4,474 GFA = 5 SPACES

S-1 6,298 GFA = 7 SPACES

TOTAL 12 SPACES

TOTAL PARKING PROVIDED = 19 SPACES

ACCESSIBLE VAN PARKING = 1

ACCESSIBLE PARKING = 1

STANDARD PARKING = 15

EV FLEET PARKING = 2

CODE COMPLIANCE

SEPARATE SUBMITTALS

MECHANICAL, ELECTRICAL, PLUMBING

BMEC323524 BELE323525 BPLM323527

UNDER SEPARATE REVIEW & PERMIT

PRIVATE OFFICE IMPROVEMENTS:

NEW COPY AREA MILLWORK, PARTITION TO SPLIT CONFERENCE 115, ASSOCIATED

MECHANICAL, ELECTRICAL, LIGHTING, & PATCH/REPAIR FINISHES

ACCESSIBLE RESTROOM IMPROVEMENTS:

ENLARGING MEN & WOMEN, ADJUSTING FIXTURE LOCATIONS, ADDING WATER CLOSET,

CONVERTING EXISTING RESTROOM TO ACCESSIBLE SINGLE OCCUPANCY; ASSOCIATED

MECHANICAL, ELECTRICAL, LIGHTING, & FINISHES

WAREHOUSE IMPROVEMENTS:

NEW WORK ROOM, FINISHES, NEW MILLWORK, NEW CHAINLINK ENCLOSURE WITH

ROLLING GATE AND TWO MAN GATE OPENINGS, STRUCTURAL SUPPORTS TO ENLARGE

ROLL UP DOOR OPENING AT EXTERIOR WALL, NEW ROLL UP DOOR; ASSOCIATED

MECHANICAL, ELECTRICAL, LIGHTING, ETC.

ROOF IMPROVEMENTS:

NEW ROOF HATCH, ROOF RESTORATION

SITE IMPROVEMENTS:

NEW EV PARKING, NEW PARKING STRIPING, ADDING ENLARGED ROLLING GATE OPENING

AT EXISTING FENCING, ACCESSIBLE PARKING SIGNAGE, NEW 400A PANEL

BUILDING INFORMATION

TI

D

R A

D

IO

A

SS

ET

S

ER

VI

C

ES

W

. O C

EA

N

B

LV

D

LO

N

G B

EA

C

H

C A

C

IT

Y

O F

LO

N

G B

EA

C

H

D

EP

A R

TM

EN

T O

F

PU

B

LI

C W

O R

K S

PL

O

T D

A

TE

M ay . 4

, 2

SA

V

ED

P

A

TH

P:

\k ar de nt d es ig n\

PR

O

JE

C

TS

\1

.1 ti d ra di o a ss et s er vi ce s bu ild in g\ dr aw in g fil es

\0 4_ co nd oc s

LA

ST

S A

V

ED

B Y:

e bo ar d

PROJECT SITE:

2961 REDONDO AVE

SCALE: NONE

VICINITY MAP

CITY OF

LONG BEACH

R

ED

O N

D O

A

VE

, L O

N G

B

EA

C H

, C A

City of Long Beach, California 2025.

KARDENT

A R C H I T E C T U R E D E S I G N

11 Golden Shore, Suite 540 | Long Beach | CA 90802 | 562.436.9900 c

EB

JLJL

EB

B-4854

TID RADIO & ASSET SERVICES BUILDING

2961 REDONDO AVE, LONG BEACH, CA, 90806

March 31, 2027

G E N L I

L I C

ENSED ARCH I TECT

STATE OF CAL I FORN IA

C-39258

RENEWAL

DATE

/2

6/

PL

A N

C H

EC

K

R

ES

U B

M

IT

TA

L

B R

M D

/1

0/

PL

A N

C H

EC

K

S U

B M

IT

TA

L

/0

9/

PL

A N

C H

EC

K

R

ES

U B

M

IT

TA

L

/0

3/

IS

SU

E

FO

R

C O

N

SR

U C

TI

O

N

A-0.00

COVER SHEET

IS

SU

E

FO

R

0%

IS

SU

E

FO

R

0%

A-1.02 POWER SIGNAL PLAN

INTERIOR & MILLWORK ELEVATIONS

FINISH PLAN - WALL

A-6.01

DETAILS - MILLWORKD-3.01

A-6.02

ARCHITECTURAL DETAILS

M-6.02 MECHANICAL DETAILS

M-6.03 MECHANICAL DETAILS

E-2.02 ELECTRICAL REMODEL LIGHTING PLAN

PLUMBING

P-0.01 GENERAL NOTES, LEGEND, SCHEDULES & SHEET INDEX

P-2.01

PLUMBING REMODEL PLAN

P-3.01 PLUMBING ENLARGED PLAN

P-2.02

PLUMBING DEMOLITION PLAN

STRUCTURAL

S-0.1 GENERAL STRUCTURAL NOTES & DRAWING INDEX

S-0.2 GENERAL STRUCTURAL NOTES CONT.

S-0.3 SYMBOLS AND ABBREVIATIONS

S-2.01 FIRST FLOOR PLAN

S-2.02 ROOF FRAMING PLAN

S-3.01 SECTIONS AND DETAILS

DEFERRED SUBMITTALS

FIRE SPRINKLER, FIRE ALARM,

PALLET RACKS, WIRE RACKS

UNDER SEPARATE REVIEW & PERMIT

E-0.04 INDOOR T-24 COMPLIANCE FORMS

E-0.05 OUTDOOR T-24 COMPLIANCE FORMS

E-0.06 NORMAL PHOTOMETRIC CALCULATIONS

E-0.07

E-6.01 ELECTRICAL DETAILS

M-0.03 T-24 COMPLIANCE FORMS

M-0.04 T-24 COMPLIANCE FORMS

M-0.05 T-24 COMPLIANCE FORMS

E-3.01 ELECTRICAL PLAN ROOF LEVEL

PLUMBING ROOF PLANP-2.03

M-6.04 MECHANICAL DETAILS

A-3.02 INTERIOR ELEVATIONS

FOR BIDDING PURPOSES ONLY

# OF

FEMALE WATERCLOSETS

MALE FEMALE

OCCUPANCY TYPE: B / OFFICE

11 1

2022 CPC

TABLE 4-1

OCC.

LOAD

FACTOR

3,046/150 =21

# OF

MALE

URINALS

MALE FEMALE

BATHTUBS

OR

SHOWERS

DRINKING

FOUNTAINS

# OF

FEMALE

OCCUPANCY TYPE: S-1

2022 CPC

TABLE 4-1

OCC.

LOAD

FACTOR

6,247/4000 =2

1 PER 250

# OF

MALE

NA 1

LAVATORIES

REQUIRED

PROVIDED

REQUIRED

PROVIDED

SERVICE

SINK

1 1 1

MALE 1 PER 150

WATERCLOSETS URINALS

BATHTUBS

OR

SHOWERS

DRINKING

FOUNTAINS

LAVATORIES SERVICE

SINK

MALE FEMALE MALE FEMALEMALE

NANA1 1 1 1 1 1

1 3 2 02 2 00

1 0 0 101

PLUMBING FIXTURE CALCULATION

TABLE 422.1 MIN PLUMBING FACILITIES

TABLE 422.1 MIN PLUMBING FACILITIES

EXISTING

EXISTING

1 2 2 02 2 00

1 0 1 03 0 10

PL

A

N C

H

EC

K R

E-

SU

B M

IT

TA

L

1 68

R E-

SU

B

M

IT

TA

L navilla Text Box

FOR BIDDING PURPOSES ONLY

1. CONSTRUCTION WASTE MATERIALS ARE TO BE RECYCLED, CONTRACTOR TO

FOLLOW THE REQUIREMENTS OF THE LOCAL JURISDICTION. CONTRACTOR TO

SUBMIT WASTE MANAGEMENT FORMS AND DEPOSIT PRIOR TO PULLING PERMITS.

G.C. CONSTRUCTION WASTE NOTES

G.C. DEMOLITION NOTES

1. REVIEW CONSTRUCTION DOCUMENTS AND FIELD CONDITIONS PRIOR TO

COMMENCING WITH DEMOLITION AND IMMEDIATELY REPORT DISCREPANCIES TO

KARDENT FOR DIRECTION ON HOW TO PROCEED

2. UPON DISCOVERY OF CONCEALED OR UNANTICIPATED ITEMS (ASBESTOS, PLUMBING,

DUCTWORK, ETC.) CONTACT KARDENT PRIOR TO REMOVAL OF THESE ITEMS

3. DEMOLITION IS NOT NECESSARILY LIMITED TO WHAT IS SHOWN, BUT IS TO INCLUDE

WHAT IS NECESSARY TO COMPLETE THE WORK IN ACCORDANCE WITH FULL SCOPE OF

THESE DOCUMENTS

4. COORDINATE DEMOLITION PLAN WITH PARTITION PLAN INCLUDING ALL GENERAL

NOTES AND PLAN INFORMATION

5. DEMOLITION DRAWINGS PREPARED BY KARDENT ARE FOR A GENERAL DESCRIPTION

OF EXISTING BUILDING COMPONENTS, ASSEMBLIES AND MATERIALS TO BE REMOVED.

VERIFY ALL EXISTING CONDITION AND QUANTITIES

6. PROTECT EXISTING CONSTRUCTION PRIOR TO AND DURING DEMOLITION PHASE.

PROTECTION TO BE MAINTAINED UNTIL COMPLETION OF DEMOLITION AND

CONSTRUCTION. ANY DAMAGE TO NEW AND EXISTING CONSTRUCTION STRUCTURE

OR EQUIPMENT SHALL BE CONTRACTOR'S RESPONSIBILITY AND SHALL BE

IMMEDIATELY REPAIRED OR REPLACED TO THE SATISFACTION OF THE CLIENT AT THE

EXPENSE OF THE GENERAL CONTRACTOR

7. FURNISH ALL LABOR, MATERIALS & EQUIPMENT AS REQUIRED TO COMPLETE

DEMOLITION AND REMOVAL OF ALL ITEMS AS INDICATED OR DIRECTED BY KARDENT

8. COORDINATE WITH CLIENT REPRESENTATIVE ALL ASPECTS OF THE DEMOLITION AND

CONSTRUCTION WORK. EXECUTE ALL WORK WITHIN THE REGULATIONS OF PROPERTY

CLIENT FOR DEMOLITION & REMOVAL OF DEBRIS, INCLUDING AFTER HOUR WORK, AS

REQUIRED

9. COORDINATE WITH CLIENT REPRESENTATIVE REGARDING SCHEDULING OF

CUTTING/CORING OF SLAB, SHOOTING OF TRACK, PLUMBING AND OTHER

NOISE-RELATED CONSTRUCTION ACTIVITIES.

10. REMOVAL OF ANY EQUIPMENT, CABLING, SWITCHES AND CONDUIT PERTAINING TO

DATA, COMMUNICATIONS AND TELEPHONES SHALL BE VERIFIED WITH CLIENT

REPRESENTATIVE AS REQUIRED TO PREVENT CONSTRUCTION DELAYS

11. REMOVE AND DISPOSE OF ALL DEMOLISHED MATERIALS IN A MANNER COMPLIANT TO

FEDERAL, STATE AND LOCAL MUNICIPAL REQUIREMENTS AND GUIDELINES

12. REFERENCE PLUMBING, MECHANICAL AND ELECTRICAL DEMOLITION DRAWINGS FOR

ADDITIONAL COORDINATION OF ITEMS TO BE REMOVED OR PROTECTED IN PLACE

13. WHERE CONSTRUCTION TO BE REMOVED INTERSECTS CONSTRUCTION TO REMAIN,

WORK SHALL INCLUDE OF ALL ATTACHMENT DEVICES (SHOT PINS, ANCHORS, LAG

BOLTS, NAILS, NAILERS, SHIMS, ETC.)

14. COORDINATE THE STORAGE OF SALVAGED MATERIALS: DOORS, FRAMES, HARDWARE,

HVAC EQUIPMENT, LIGHT FIXTURES, MILLWORK AND FURNITURE WITH THE CLIENT

REPRESENTATIVE

15. FURNISH THE CLIENT REPRESENTATIVE WITH A COMPLETE INVENTORY LIST OF ALL

ITEMS THAT CAN BE REUSED AND/OR STORED IN BUILDING ATTIC STOCK, AND OBTAIN

DIRECTIVE REGARDING THEIR DISPOSITION

16. ALL DEMOLISHED MATERIAL OTHER THAN ITEMS TO BE SALVAGED, REUSED OR

RETURNED TO THE CLIENT SHALL BECOME CONTRACTORS PROPERTY UNO, AND

SHALL BE REMOVED FROM THE PREMISES. CLEAN UP AND DISPOSE OF DEBRIS

PROMPTLY AND CONTINUOUSLY AS THE WORK PROGRESSES. SECURE AND PAY FOR

REQUIRED HAULING PERMITS, PAY DUMPING FEES AND CHARGES.

17. REMOVE FROM PREMISES ALL CONDUITS, BOXES, PLATES, BRIDGES, OR ANY OTHER

TELEPHONE AND/OR ELECTRICAL WIRING & EQUIPMENT LEFT AFTER WALL

DEMOLITION

18. REMOVE ALL UNUSED DATA/TELE CABLING IN CEILING BACK TO SOURCE UNO

19. REMOVE EXISTING CEILING FINISHES (ACOUSTICAL TILE) AND SUBSTRATE (GYPSUM

BOARD, PLASTER) AND RELATED SUSPENSION SYSTEMS WHERE NOTED ON DRAWINGS

IN ALL ROOMS DESIGNATED TO RECEIVE NEW CEILING FINISHES (AND SUSPENSION

SYSTEMS) PER REFLECTED CEILING PLAN

20. REMOVE EXISTING WALL FINISHES (CERAMIC TILE, VINYL WALL COVERING, PLYWOOD,

GYPSUM BOARD SUBSTRATES, PLASTER, ETC.) IN ALL ROOMS DESIGNATED TO RECEIVE

NEW WALL FINISHES PER INTERIOR FINISH SCHEDULE

21. REMOVE EXISTING FLOORING & BASE (CERAMIC TILE, CARPET, PADDING AND

ACCESSORIES) IN ALL ROOMS DESIGNATED TO RECEIVE NEW FLOORING AND BASE PER

INTERIOR FINISH PLANS

22. PROVIDE ALL FLOOR CUT-OUTS AND PATCHING REQUIRED FOR THE INSTALLATION OF

ALL WORK

23. VERIFY NECESSITY OF SLAB X-RAYING PRIOR TO COMMENCEMENT OF CORING OR

CUTTING OF SLAB, REFERENCE ELECTRICAL PLANS. NOTIFY KARDENT OF ANY

STRUCTURAL OR EQUIPMENT CONFLICTS PRIOR TO CORING OR CUTTING OF SLAB

24. PATCH ALL CRACKS, HOLES OR OTHER IMPERFECTIONS (PROJECTIONS SHALL BE

REMOVED AND PATCHED) TO PROVIDE A CONTINUOUS SMOOTH FLOOR SURFACE

25. PREPARE UNEVEN AND OR DAMAGED SUB-FLOOR (WHERE EXISTS) AS NEEDED FOR

SMOOTH AND LEVEL FLOORING. NOTIFY KARDENT AFTER FLOOR PATCHING IS DONE

TO RECEIVE APPROVAL PRIOR TO INSTALLATION OF FINISHED FLOORING

26. REMOVE ALL EXISTING IRREGULAR MATERIALS WHICH MIGHT CAUSE RISE IN FLOORING

SURFACE; SUCH AS: FASTENERS, OUTLETS, FLASH PATCH, CONCRETE FILL, ETC. UNO

27. DOWEL/FILL/PATCH SLAB AFTER SAWCUTTING TO ENSURE SLAB STRUCTURAL

INTEGRITY

28. PATCH ALL SCARS, BLEMISHES AND RELATED DUE TO DEMOLITION. PREPARE

DEMOLISHED AREA FOR NEW WORK.

29. REPAIR ALL SURFACES DESIGNATED TO RECEIVE NEW FLOOR, WALL, AND CEILING

FINISHES AS REQUIRED TO PROVIDE A SOUND AND FLUSH SUBSTRATE

30. COMPLETE ALL CUTTING, FITTING AND PATCHING WORK THAT MAY BE REQUIRED TO

MAKE ALL PARTS COME TOGETHER PROPERLY, AND FIT TO RECEIVE OR BE RECEIVED BY

WORK OF OTHER CONTRACTS WHERE SHOWN, OR REASONABLY IMPLIED BY THE

DRAWINGS AND NOTES

31. ALL PROJECTING PLUMBING, FLOOR ELECTRICAL/TELEPHONE OUTLETS AND ALL

OTHER PROJECTING ITEMS WHICH ARE BEING ABANDONED TO BE CAPPED TO

PROVIDE FLUSH FINISHED SURFACES. PATCH PENETRATIONS IN FLOOR WHERE

PLUMBING OR ELECTRICAL HAVE BEEN REMOVED OR ABANDONED. FIRE RATING

(WHERE OCCURS) OF FLOOR SHALL BE MAINTAINED

32. SURVEY ALL EXISTING FINISHED SURFACES TO REMAIN FOR CHIPS, CRACKS, HOLES,

AND OTHER DAMAGES. THESE DEFECTIVE SURFACES SHALL BE REPAIRED, OF IF BEYOND

REPAIRING, THEN NOTIFY KARDENT OR CLIENT REPRESENTATIVE IMMEDIATELY FOR

FURTHER INSTRUCTIONS

33. INSPECT ALL EXISTING SURFACES TO REMAIN, AFTER DEMOLITION OF EXISTING

FINISHES (I.E. WALLCOVERING, WALL BASE, ETC.). IF SURFACE IS NOT SMOOTH AND

FLUSH TO RECEIVE NEW FINISH, SKIM COAT AND SAND SMOOTH

34. ALL EXISTING OR NEW CONSTRUCTION WORK SHOWN ON THE DRAWINGS THAT IS

DAMAGED AS A RESULT OF WORK FOR THIS PROJECT, SHALL BE PATCHED OR REPAIRED

TO MATCH IMMEDIATE EXISTING ADJACENT AREAS IN MATERIALS, FIRE RATING, FINISH,

AND COLOR UNO

35. ALL EXISTING ITEMS TO REMAIN SHALL BE REFURBISHED UNO. LOOSE ITEMS SHALL BE

TIGHTENED AND ANY MISSING OR BROKEN PARTS SHALL BE REPLACE BY THE

CONTRACTOR TO ACHIEVE A FINISHED "LIKE NEW" APPEARANCE. PATCH AND REPAIR

EXISTING DOORS, FRAMES AND HARDWARE AS NEEDED

36. UPON COMPLETION OF THE DEMOLITION WORK, ENSURE THAT ALL AREAS ARE LEFT IN

A CLEAN AND BROOM SWEPT CONDITION

G.C. GENERAL NOTES

1. VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO COMMENCEMENT OF

WORK. THIS INCLUDES: UTILITIES, ALL OTHER WORKS AND FACILITIES THAT AFFECT THIS

PROJECT. NO ALLOWANCE SHALL BE MADE FOR ANY EXTRA EXPENSE OR EXTENSION OF

TIME DUE TO CONTRACTORS FAILURE OR NEGLECT OF COMPLETE EXAMINATION OF THE

JOB SITE

2. ANY DISCREPANCIES, CONFLICTS OR OMISSIONS ETC., SHALL BE NOTIFIED TO KARDENT

PRIOR TO PROCEEDING WITH THE WORK

3. SUBMIT TO THE CLIENT REPRESENTATIVE A DETAILED CONSTRUCTION SCHEDULE

INDICATING PHASING OF WORK FROM START TO FINISH OF PROJECT, INCLUDING A

CRITICAL PATH SCHEDULE

4. ENTERING INTO AN AGREEMENT WITH THE CLIENT INDICATES THAT THE CONTRACTOR(S)

HAVE VISITED THE JOB SITE, FAMILIARIZED THEMSELVES WITH EXISTING CONDITIONS

AND REVIEWED THE SAME WITH THE REQUIREMENTS OF THE CONTRACT DOCUMENTS

5. PROVIDE NECESSARY PERMITS REQUIRED BY FEDERAL, STATE AND LOCAL MUNICIPAL

AGENCIES HAVING JURISDICTIONAL AUTHORITY. THE CONTRACTOR SHALL OBTAIN AND

PAY FOR THE BUILDING PERMIT. EACH SUBCONTRACTOR SHALL OBTAIN AND PAY FOR

SUCH PERMITS, LICENSES AND INSPECTIONS NECESSARY FOR PERFORMANCES OF HIS

WORK AND INCLUDE THOSE IN THE COST OF THE WORK TO THE CLIENT

6. PROVIDE THE MINIMUM INSURANCE REQUIREMENTS SET FORTH IN ARTICLE II A.I.A.

DOCUMENTS A201, GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION

7. MAINTAIN A CURRENT AND COMPLETE SET OF CONSTRUCTION DOCUMENTS ON THE

JOB SITE DURING ALL PHASES OF CONSTRUCTION FOR USE BY ALL TRADES AND PROVIDE

ALL SUB CONTRACTORS WITH CURRENT CONSTRUCTION DOCUMENTS.

8. ANY AND ALL REVISIONS SHALL BE WRITTEN CHANGE ORDER FORM, APPROVED AND

AUTHORIZED BY KARDENT BEFORE BEGINNING WORK.

9. THE INTENT OF THE DRAWING IS TO SHOW EXISTING BUILDING CONDITIONS WITH

INFORMATION DEVELOPED FROM VISUAL OBSERVATION. UNIDENTIFIED ITEMS SHALL BE

BROUGHT TO THE IMMEDIATE ATTENTION OF THE CLIENT REPRESENTATIVE AND

KARDENT PRIOR TO REMOVAL

10. DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN, UNLESS OTHERWISE NOTED. LARGE

SCALE DETAILS GOVERN OVER SMALL SCALE DETAILS

11. ALL SYMBOLS AND ABBREVIATIONS USED ON THE DRAWINGS ARE CONSIDERED

CONSTRUCTION STANDARDS. IF THE CONTRACTOR HAS QUESTIONS REGARDING THEIR

EXACT MEANING, CLARIFICATION SHALL BE REQUESTED FROM KARDENT

12. INSURE THAT INSTALLATION METHODS CONFORM TO ALL BUILDING CODE

REQUIREMENTS. THE MATERIALS SPECIFIED ARE INTENDED TO MEET CODE

REQUIREMENTS. DISCREPANCIES BETWEEN THE CONSTRUCTION DOCUMENTS AND CODE

REQUIREMENTS SHALL BE BROUGHT TO THE ATTENTION OF KARDENT IMMEDIATELY BY

THE CONTRACTOR PRIOR TO PROCEEDING WITH FURTHER WORK

13. IT SHALL BE UNDERSTOOD, UNO, THAT ALL MATERIALS AND WORKMANSHIP SHALL BE

GUARANTEED FOR A MINIMUM PERIOD OF ONE YEAR FROM THE ACCEPTANCE OF THE

PROJECT BY THE CLIENT.

14. NO SUBSTITUTIONS OF SPECIFIED MATERIALS SHALL BE PERMITTED WITHOUT FIRST

SUBMITTING SPECIFICATIONS, SAMPLES AND COST IMPACT FOR KARDENT'S REVIEW AND

APPROVAL

15. ANY REVISION OR ADDITIONAL WORK REQUIRED BY THE CLIENT, FIELD CONDITIONS OR

LOCAL GOVERNING AUTHORITIES SHALL BE BROUGHT TO THE ATTENTION OF THE

CLIENT OR KARDENT BEFORE PROCEEDING REGARDLESS OF COST, TIME OR MATERIAL

INCREASE

16. THE CONSTRUCTION DOCUMENTS ARE PROVIDED TO ILLUSTRATE THE DESIGN AND

GENERAL TYPE OF CONSTRUCTION DESIRED AND IMPLY THE FINEST QUALITY OF

CONSTRUCTION, MATERIALS AND WORKMANSHIP. THE GENERAL CONTRACTOR IN

ASSUMING RESPONSIBILITY FOR THE WORK INDICATED SHALL COMPLY WITH THE SPIRIT

AS WELL AS THE LETTER IN WHICH THEY WERE DRAWN.

17. PROTECT AREA AND NEW OR EXISTING MATERIALS AND FINISHES FROM DAMAGE WHICH

MAY OCCUR FROM CONSTRUCTION, DEMOLITION,DUST,WATER, ETC. AND PROVIDE

AND MAINTAIN TEMPORARY BARRICADES, CLOSURE WALLS,ETC. AS REQUIRED TO

PROTECT THE PUBLIC DURING CONSTRUCTION. DAMAGE TO NEW AND EXISTING

MATERIAL,FINISHES, STRUCTURE AND EQUIPMENT SHALL BE REPAIRED OR REPLACED TO

THE SATISFACTION OF THE CLIENT'S REPRESENTATIVE AT THE EXPENSE OF THE

CONTRACTOR

18. PROVIDE A VISQUEEN SEAL FROM FLOOR TO CEILING AT INTERFACES TO PROTECT

ADJACENT BUILDING SUITE/SPACE WHILE DEMOLITION AND CONSTRUCTION ARE IN

PROGRESS. THIS SEAL IS TO BE KEPT CLOSED AT ALL TIME

19. VERIFY REQUIRED LOCATIONS OF ALL NECESSARY ACCESS PANELS (IN PARTITIONS,

FLOORS OR CEILINGS) AND COORDINATE EXACT LOCATIONS WITH ALL TRADES AND

CONFIRM WITH KARDENT

20. LEAVE THE BUILDING IN A LOCKABLE CONDITION DURING THE PERIOD OF THIS WORK

WHEN CONTRACTOR'S AND SUBCONTRACTORS' WORKERS ARE NOT AT THE JOB SITE

21. DEACTIVATE ALL UTILITY LINES IN CONTRACT AREA BEFORE STARTING WORK AND SECURE

PERMISSION FROM CLIENT/PROPERTY MANAGEMENT PRIOR TO DEACTIVATION

22. PATCH, REPAIR, REPLACE AND/OR REFINISH ANY EXISTING CONSTRUCTION IN THE

CONTRACT AREA, UNO

23. PROVIDE ALL WORK SHOWN ON THE DRAWINGS UNLESS SPECIFICALLY NOTED AS NOT

IN CONTRACT. (N.I.C.)

24. THE BUILDING SHALL COMPLY WITH TITLE 24, CHAPTER 11B ACCESSIBILITY

REQUIREMENTS FROM THE PATH OF TRAVEL FROM THE PUBLIC WAY TO THE ACCESSIBLE

PARKING AND BUILDING ENTRANCE(S) TO THE AREA BEING REMODELED AND

RESTROOMS SERVING THE AREA.

25. ALL CONSTRUCTION WORK, STRUCTURAL, ARCHITECTURAL, MECHANICAL, ELECTRICAL,

PLUMBING, ETC. SHALL CONFORM TO THE LATEST EDITION OF ALL GOVERNING CODES

AND REGULATIONS

26. ALL WORK LISTED, SHOWN OR IMPLIED ON ANY CONSTRUCTION DOCUMENT SHALL BE

SUPPLIED AND INSTALLED BY THE GENERAL CONTRACTOR UNO. THE GENERAL

CONTRACTOR SHALL CLOSELY COORDINATE HIS WORK WITH THAT OF OTHER

SUB-CONTRACTORS

27. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY BLOCKING, BACKING, FRAMING,

HANGERS OR OTHER SUPPORT FOR ALL FIXTURES, EQUIPMENT, CABINETRY, FURNISHINGS

AND ALL OTHER ITEMS REQUIRING THE SAME.

28. CONFINE EQUIPMENT, DELIVERY AND STORAGE OF MATERIALS AND THE OPERATION OF

WORKMEN TO THE LIMITS DEFINED BY THE CLIENT REPRESENTATIVE

29. STORE OF ALL MATERIALS DURING CONSTRUCTION IN A MANNER THAT PREVENTS LIVE

LOADS FROM EXCEEDING THOSE ALLOWED IN THE BUILDINGS STRUCTURAL DESIGN

30. REMOVE ALL RUBBISH AND WASTE MATERIALS ON A REGULAR BASIS, OF ALL

SUB-CONTRACTORS AND TRADES. EXERCISE STRICT CONTROL OVER JOB CLEANING

THROUGHOUT CONSTRUCTION, INCLUDING FINAL CLEAN UP UPON COMPLETION OF

WORK.

31. BEFORE ACCEPTANCE BY THE GENERAL CONTRACTOR, THE COMPLETED CONSTRUCTION

SHALL BE CLEANED, LABELS REMOVED AND ALL OTHER TOUCH UP COMPLETED PRIOR TO

SCHEDULING A PUNCH WALK WITH KARDENT, CLIENT AND/OR BUILDING MANAGEMENT

32. AT THE TIME OF FINAL BID SUBMITTAL, THE CONTRACTOR SHALL ADVISE KARDENT (IN

WRITING) OF ANY SPECIFIED MATERIALS OR EQUIPMENT WHICH ARE EITHER

UNAVAILABLE OR WILL CAUSE A DELAY IN THE CONSTRUCTION COMPLETION SCHEDULE

33. BID PRICING SHALL BE ITEMIZED AS FOLLOWS: DEMOLITION, CONCRETE WORK,

MASONRY, STEEL/METALS, WOOD, MILLWORK, DOORS/FRAMES & HARDWARE,

GLASS/GLAZING, DRYWALL & ACOUSTICAL CEILINGS, FLOORING, PAINTING, PLUMBING,

ELECTRICAL, HVAC, AND ROOFING. CONTRACTOR SHALL ALSO INCLUDE: CLEANING

AND PROTECTION/DUMPSTERS, GENERAL CONDITIONS AND INSURANCE, AND

SUPERVISION FEES.

1. SUBMIT ALL REQUESTED FABRICATION SHOP DRAWINGS, SAMPLES AND FIXTURE CUT

SHEETS TO KARDENT FOR REVIEW, COMMENTS AND/OR APPROVAL. ALL SHOP

DRAWINGS AND CUT SHEETS SIGNED "APPROVED" SHALL SUPERSEDE ORIGINAL

DRAWINGS IN DESIGN APPEARANCE ONLY. SUBCONTRACTORS SHALL ASSUME

RESPONSIBILITY FOR ERRORS IN THEIR DRAWINGS.

2. REVIEW ALL SUBCONTRACTORS' SUBMITTED DRAWINGS AND CUT SHEETS, VERIFY FIELD

MEASUREMENTS AS REQUIRED AND SUBMIT TO KARDENT FOR REVIEW AND APPROVAL.

3. DISAPPROVE AND RETURN TO SUBCONTRACTOR ANY SUBMITTALS NOT MEETING THE

REQUIREMENTS OF THE CONTRACT DOCUMENTS. GENERAL CONTRACTOR SHALL

MAINTAIN AN UP-TO-DATE SUBMITTAL LOG, DISTRIBUTE THE LOG WEEKLY AND A FINAL

LOG AT COMPLETION OF THE PROJECT.

4. KARDENT WILL REVIEW, AND EITHER ACCEPT OR REJECT, WITH REASONABLE

PROMPTNESS AND AS OUTLINED IN THE ACCEPTED SUBMITTAL SCHEDULE, DATA, AND

DRAWINGS SUBMITTED BY THE CONTRACTOR. THE ARCHITECT WILL REVIEW

SUBMITTALS FOR CONFORMANCE WITH THE INTENT OF THE DESIGN, AND FOR

COMPLIANCE WITH SPECIFIC AND RELEVANT REQUIREMENTS OF THE CONTRACT

DOCUMENTS.

5. KARDENT WILL REJECT AND RETURN TO THE CONTRACTOR, SHOP DRAWINGS AND

CUT SHEETS SUBMITTED WITHOUT THE CONTRACTOR'S REVIEW STAMP AND/OR NOT

THOROUGHLY REVIEWED BY CONTRACTOR PRIOR TO SUBMITTAL.

6. KARDENT IS NOT RESPONSIBLE FOR DELAYS CAUSED BY REJECTION OF SHOP

DRAWINGS SUBMITTED BY THE CONTRACTOR.

7. REVIEW WILL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR ERRORS.

8. REVIEW OF SUBMITTALS BY KARDENT SHALL NOT BE CONSTRUED AS AUTHORIZING

CHANGES IN THE CONTRACT SUM OR CONTRACT, TIME NOR SHALL IT BE CONSTRUED

AS RELIEVING THE CONTRACTOR OF HIS RESPONSIBILITY FOR COORDINATION OF

WORK WITH OTHER TRADES, OR INTERPRETED AS APPROVING QUANTITIES AND

DIMENSIONS.

9. KARDENT'S REVIEW OF SUBMITTALS OR DATA SHALL NOT RELIEVE THE CONTRACTOR

FROM RESPONSIBILITY FOR DEVIATIONS FROM THE CONTRACT DRAWINGS OR

SPECIFICATIONS UNLESS THE CONTRACTOR HAS CALLED THE ARCHITECT'S AND

CLIENT'S ATTENTION TO DEVIATIONS AND SECURED WRITTEN ACCEPTANCE, NOR

SHALL IT RELIEVE HIM OF RESPONSIBILITY FOR ERRORS IN SHOP DRAWINGS OR OTHER

DATA.

G.C. SUBMITTAL PROCEDURES

G.C. STORM WATER PREVENTION NOTES

1. FUELS, OIL, SOLVENTS & OTHER TOXIC MATERIALS SHALL BE STORED IN

ACCORDANCE WITH THEIR LISTING & ARE NOT TO CONTAMINATE THE SOIL &

SURFACE WATERS. ALL APPROVED STORAGE CONTAINERS ARE TO BE PROTECTED

FROM THE WEATHER. SPILLS MUST BE CLEANED UP IMMEDIATELY & DISPOSED OF IN A

PROPER MANNER. SPILLS MAY NOT BE WASHED INTO THE DRAINAGE SYSTEM, NOR BE

ALLOWED TO SETTLE OR INFILTRATE INTO SOIL.

2. EXCESS OR WASTE CONCRETE MAY NOT BE WASHED INTO THE PUBLIC WAY OR ANY

OTHER DRAINAGE SYSTEM. PROVISIONS SHALL BE MADE TO RETAIN CONCRETE

WASTE ON SITE UNTIL THEY CAN BE DISPOSED OF AS SOLID WASTES.

3. TRASH & CONSTRUCTION SOLID WASTES SHALL BE DEPOSITED INTO A COVERED

RECEPTACLE TO PREVENT CONTAMINATION OF RAINWATER & DISPERSAL BY WIND.

4. SEDIMENTS & OTHER MATERIALS MAY NOT BE TRACKED FROM THE SITE BY

VEHICULAR TRAFFIC. THE CONSTRUCTION ENTRANCE ROADWAYS MUST BE

STABILIZED SO AS TO INHIBIT SEDIMENTS FROM BEING DEPOSITED INTO THE PUBLIC

WAY. ACCIDENTAL DEPOSITS SHALL BE SWEPT UP IMMEDIATELY & MAY NOT BE

WASHED DOWN BY RAIN OR OTHER MEANS.

5. ANY SLOPES WITH DISTURBED SOILS OR REMOVED VEGETATION SHALL BE STABILIZED

TO INHIBIT EROSION BY WIND & WATER.

6. STORM WATER POLLUTION PREVENTION DEVICES &/OR PRACTICES SHALL BE

MODIFIED AS NEEDED AS THE PROJECT PROGRESS TO ENSURE EFFECTIVENESS.

EB EB

PL

O

T D

A

TE

M ay . 4

, 2

SA

V

ED

P

A

TH

P:

\k ar de nt d es ig n\

PR

O

JE

C

TS

\1

.1 ti d ra di o a ss et s er vi ce s bu ild in g\ dr aw in g fil es

\0 4_ co nd oc s

LA

ST

S A

V

ED

B Y:

e bo ar d KARDENT

A R C H I T E C T U R E D E S I G N

11 Golden Shore, Suite 540 | Long Beach | CA 90802 | 562.436.9900

JL JL

TI

D

R A

D

IO

A

SS

ET

S

ER

VI

C

ES

R

ED

O

N D

O A

VE

, L

O N

G B

EA

C

H , C

A

B-4854

March 31, 2027

G E N L I

L I C

ENSED ARCH I TECT

STATE OF CAL I FORN IA

C-39258

RENEWAL

DATE

/2

6/

PL

A N

C H

EC

K

R

ES

U B

M

IT

TA

L

B R

M D

/1

0/

PL

A N

C H

EC

K

S U

B M

IT

TA

L

City of Long Beach, California 2025.c

/0

9/

PL

A N

C H

EC

K

R

ES

U B

M

IT

TA

L

/0

3/

IS

SU

E

FO

R

C O

N

ST

R U

C

TI

O N

A-0.11

GENERAL NOTES

1. NOTIFY THE MECHANICAL ENGINEER FOR REVIEW OF MECHANICAL WORK PRIOR TO

INSPECTION AND CLOSING-UP CEILING

2. HVAC SUBCONTRACTOR SHALL BE RESPONSIBLE FOR FIELD SUPERVISION OF ALL

THEIR WORK DURING INSTALLATION AND SHALL INSPECT ALL SYSTEMS FOR PROPER

OPERATIONS AT COMPLETION OF JOB

3. SUBMIT SHOP DRAWINGS OF ALL HVAC EQUIPMENT, REGISTERS, INCLUDING ACCESS

PANELS IF REQUIRED TO KARDENT FOR REVIEW AND APPROVAL PRIOR TO

PROCEEDING WITH FABRICATION AND/OR INSTALLATION OR RELOCATION

4. COORDINATE INSTALLATION WITH ALL TRADES AS REQUIRED FOR PROPER ASSEMBLY.

CEILING DIFFUSERS TO BE RELOCATED TO ACCOMMODATE NEW LIGHT FIXTURE

PATTERNS INDICATED ON THE DRAWINGS. NOTIFY KARDENT IMMEDIATELY OF ANY

DISCREPANCIES FROM FIELD CONDITIONS

5. THE MECHANICAL ENGINEER SHALL PROVIDE NECESSARY ENGINEERING DRAWINGS

AND CALCULATIONS TO REWORK ALL EXISTING EQUIPMENT AND TO DETERMINE ALL

NEW EQUIPMENT TO MEET THE CLIENT'S REQUIREMENT

6. VERIFY HVAC CONDITIONS/ZONING WITH BUILDING ENGINEER TO ENSURE

ADEQUACY OF EXISTING UNITS. ANY ADDITIONS TO HVAC TO BE INCLUDED IN

SCOPE AND BID. G.C. TO VERIFY CAPACITY OF EXISTING ELECTRICAL PANEL/

TRANSFORMER IS ADEQUATE

7. PROTECT EXISTING T-STAT (WHERE OCCURS) DURING DEMOLITION UNO

1. PROVIDE AND INSTALL ALL PLUMBING ROUGH-INS, FINAL HOOK-UP, FIXTURES,

ALLIANCES AND ACCESSORIES AS SHOWN OR IMPLIED ON THE CONSTRUCTION

DOCUMENTS UNO, AND PER CODE

2. SUBMIT CUT SHEETS OF ALL NEW FIXTURES, FITTINGS AND ACCESSORIES TO KARDENT

FOR REVIEW AND APPROVAL PRIOR TO PLACING ORDER

3. COORDINATE WORK OF THE PLUMBING SUBCONTRACTOR WITH ALL OF THE OTHER

TRADES

4. FURNISH ALL VALVES AS INDICATED ON THE DRAWINGS, OR AS MAY BE REQUIRED

FOR THE PROPER CONTROL OF THE VARIOUS APPARATUS AND PIPELINES INSTALLED

UNDER THIS SECTION SO THAT ANY FIXTURE LINES OR PIECE OF APPARATUS MAY BE

CUT OFF FOR REPAIR WITHOUT INTERFERENCE OR INTERRUPTION OF THE SERVICE

TO THE REST OF THE BUILDING

5. PROVIDE & INSTALL FOAM OR FIBER INSULATION WITH PROTECTIVE OVERLAP ON

DRAIN, HOT WATER SUPPLY AND SHARP OBJECTS BELOW LAVATORY.

6. BEFORE BEING COVERED UP OR BUILT-IN, PIPING SHALL BE TESTED AS REQUIRED BY

THE AUTHORITIES HAVING JURISDICTION

7. PROVIDE ACCESS PANELS AT ALL CLEAN OUTS

1. GENERAL: CONSTRUCTION SHALL COMPLY WITH THE AIR LEAKAGE REQUIREMENTS

OF THE CALIFORNIA ENERGY CODE 140.3 FOR WINDOWS, DOORS, CAULKING AND

SEALING

2. WINDOWS: (UNDER SHELL BUILDING WORK) FIXED WINDOWS CONSTRUCTED

AND/OR ERECTED ON SITE SHALL BE SEALED TO LIMIT AIR INFILTRATION IN

ACCORDANCE WITH LOCAL CODE AND MANUFACTURER SPECIFICATIONS

3. DOORS: (UNDER SHELL BUILDING WORK) ALL EXTERIOR DOORS SHALL BE SO

DESIGNED TO LIMIT AIR LEAKAGE AROUND THE PERIMETER WHEN IN A CLOSED

POSITION

a. ALL DOORS SHALL BE PROVIDED WITH A SEAL, ASTRAGAL OR BAFFLE AT THE

HEAD AND SILL

b. DOORS REQUIRING VERTICAL TRACK OR GLIDES SHALL USE A CONTINUOUS

MOUNTING ANGLE AND SEALED IN ACCORDANCE WITH SECTION T120-1495 ( E)

AT EACH END

c. DOORS MOUNTED BETWEEN THE JAMBS SHALL HAVE A CONTINUOUS SEAL OR

BAFFLE AT EACH JAMB

d. DOUBLE DOORS SHALL BE PROVIDED WITH A WEATHER-TIGHT ASTRAGAL OR

CLOSURE AT THE CENTER JAMB.MANUFACTURED DOORS SHALL HAVE AIR

INFILTRATION RATES CERTIFIED BY THE MANUFACTURER AS NOT EXCEEDING .50

CFM/SQ.FT. OF DOOR AREA FOR SINGLE DOORS, AND 1.00 CFM/SQ.FT. OF DOOR

AREA FOR DOUBLE DOORS

4. CAULKING AND SEALING: OPEN EXTERIOR JOINTS AROUND WINDOW AND DOOR

FRAMES, BETWEEN WALL AND FOUNDATION, BETWEEN WALL AND ROOF, BETWEEN

WALL PANELS, AT PENETRATIONS OF UTILITY SERVICES THROUGH WALLS, FLOORS

AND ROOFS AND ALL OTHER OPENINGS IN THE EXTERIOR ENVELOPE SHALL BE

SEALED, CAULKED OR WEATHER-STRIPPED TO LIMIT AIR LEAKAGE

5. SITE-CONSTRUCTED DOORS AND WINDOWS, EXTERIOR JOINTS, AND OPENINGS IN

THE BUILDING ENVELOPE THAT ARE OBSERVABLE SOURCES OF AIR LEAKAGE SHALL BE

CAULKED, GASKETED, WEATHER-STRIPPED OR OTHERWISE SEALED

G.C. HVAC NOTES

1. SUBMIT 1 SET OF SHOP DRAWINGS AND THREE (3) SETS OF FINISH SAMPLES TO KARDENT

FOR REVIEW

2. REFERENCE FINISH PLANS AND DETAILS FOR MILLWORK FINISH AND MATERIAL QUALITY

SPECIFICATIONS TO MEET OR EXCEED AWI STANDARDS

3. CLOSELY COORDINATE WORK WITH THAT OF THE MILLWORK SUBCONTRACTOR

4. ALL "INSTALLED" CABINETRY SHALL COMPLY WITH APPLICABLE BUILDING CODES AND

ADA REQUIREMENTS

5. ALL "INSTALLED" CABINETS SHALL BE SCRIBED TO WALL OR CEILING, UNO

6. MILLWORK SUBCONTRACTOR SHALL CHECK AND FIELD VERIFY ALL DIMENSIONS AND

CONDITIONS AT THE JOB SITE. NOTIFY ARCHITECT IMMEDIATELY OF ANY

DISCREPANCIES

7. ALL FINISHED WORK SHALL, AS FAR AS PRACTICAL, BE ASSEMBLED AND FINISHED IN THE

SHOP AND DELIVERED TO THE BUILDING READY TO INSTALL IN PLACE.

8. ALL THE WORK SHALL BE FABRICATED, ASSEMBLED, FINISHED AND INSTALLED TO MEET

WIC "STANDARD" GRADE FOR PLASTIC LAMINATE AND "PREMIUM" GRADE FOR ALL WOOD

9. WHERE FILE CABINETS ARE SHOWN AS BEING SET INTO CABINETWORK, THE MILLWORK

CONTRACTOR SHALL SET AND BOLT ALL FILE CABINETS TOGETHER, UNO

10. ALL MILLWORK SHOP DRAWINGS ARE TO CALL OUT ALL MATERIALS AND FINISHES. ALL

JOINTS, CORNERS, EDGES ARE TO BE DETAILED IN INDIVIDUAL DETAILS. ALL DIMENSIONS

CRITICAL OR OTHERWISE ARE TO BE CALLED OUT ON THE SHOP DRAWINGS. ARCHITECT

WILL NOT REVIEW DRAWINGS, WHICH ARE INCOMPLETE SHOWING MINIMAL REQUIRED

DETAILING AND INFORMATION

11. COORDINATE MILLWORK, STONE, AND/OR OTHER SPECIALTIES CONTRACTORS.

12. FULLY CONCEALED CABINET INTERIORS TO BE MELAMINE, COLOR: WHITE AT PLASTIC

LAMINATE AND COLOR: BLACK AT WOOD VENEER CABINETS, UNO

1. ALL DOOR GLAZING TO BE TEMPERED GLASS. ALL TEMPERED GLAZING SHALL BE

INDICATED AS SUCH BY A SYMBOL OR THE WORD TEMPERED GLASS ETCHED ONTO

THE GLASS

2. EACH PANE SHALL BEAR THE MANUFACTURER'S MARK DESIGNATING THE TYPE AND

THICKNESS OF THE GLASS OR GLAZING MATERIAL. THE IDENTIFICATION SHALL NOT

BE OMITTED UNLESS APPROVED AND AN AFFIDAVIT IS FURNISHED BY THE GLAZING

CONTRACTOR CERTIFYING THAT EACH LIGHT IS GLAZED IN ACCORDANCE WITH

APPROVED CONSTRUCTION DOCUMENTS THAT COMPLY WITH THE PROVISIONS OF

THIS CHAPTER. SAFETY GLAZING SHALL BE IDENTIFIED IN ACCORDANCE WITH

SECTION 2406.3

3. EACH PANE OF TEMPERED GLASS, EXCEPT TEMPERED SPANDREL GLASS, SHALL BE

PERMANENTLY IDENTIFIED BY THE MANUFACTURER. THE IDENTIFICATION MARK

SHALL BE ACID ETCHED, SAND BLASTED, CERAMIC FIRED, LASER ETCHED, EMBOSSED

OR OF A TYPE THAT, ONCE APPLIED, CANNOT BE REMOVED WITHOUT BEING

DESTROYED

4. FIRE-PROTECTION-RATED GLAZING. GLAZING IN FIRE WINDOW ASSEMBLIES SHALL BE

FIRE-PROTECTION RATED IN ACCORDANCE WITH THIS SECTION AND TABLE 716.6.

GLAZING IN FIRE DOOR ASSEMBLIES SHALL COMPLY WITH SECTION 716.5.8.

FIRE-PROTECTION-RATED GLAZING SHALL BE TESTED IN ACCORDANCE WITH AND

SHALL MEET THE ACCEPTANCE CRITERIA OF NFPA 257 OR UL 9.

FIRE-PROTECTION-RATED GLAZING SHALL ALSO COMPLY WITH NFPA 80. OPENINGS

IN NONFIRE-RESISTANCE-RATED EXTERIOR WALL ASSEMBLIES THAT REQUIRE

PROTECTION IN ACCORDANCE WITH SECTION 705.3, 705.8, 705.8.5 OR 705.8.6 SHALL

HAVE A FIRE-PROTECTION RATING OF NOT LESS THAN 3/4 HOUR.

FIRE-PROTECTION-RATED GLAZING IN 0.5-HOUR FIRE-RESISTANCE-RATED PARTITIONS

IS PERMITTED TO HAVE A 0.33-HOUR FIRE PROTECTION RATING. (CBC SEC 716.6)

G.C. MILLWORK NOTES

G.C. PLUMBING NOTES

G.C. ENERGY NOTES

G.C. GLAZING NOTES

2 68

1. FURNISH AND INSTALL ALL LIGHT FIXTURES AND ELECTRICAL WORK AS SHOWN OR

IMPLIED ON ALL DRAWINGS AND NOTES, UNO

2. INSTALL FIXTURES IN ACCORDANCE TO THE MANUFACTURER'S SPECIFICATIONS

3. THE WORK SHALL BE INSTALLED IN A STRICT ACCORDANCE WITH THE REQUIREMENTS OF

THE NATIONAL BOARD OF FIRE UNDERWRITERS, PUBLIC UTILITIES COMPANY, TELEPHONE

COMPANY, AND ALL OTHER AUTHORITIES HAVING JURISDICTION

4. ALL NEW MATERIALS REQUIRED SHALL CONFORM WITH THE STANDARDS OF THE

UNDERWRITERS LABORATORIES, INC., WHERE SUCH STANDARDS HAVE BEEN

ESTABLISHED FOR THE PARTICULAR TYPE OF MATERIAL OR FIXTURE IN QUESTION, UNO

5. PROPOSALS SHALL BE BASED UPON REMOVING AND/OR RE-INSTALLING EXISTING LIGHT

FIXTURES (INCLUDING NEW LAMPS), FURNISHING AND INSTALLING NEW LIGHT FIXTURES

OF TYPES AND MANUFACTURERS AS INDICATED ON PLANS

6. SUBMIT CUT SHEETS OF ALL FIXTURES AND CONTROLS TO KARDENT FOR REVIEW,

KARDENT TO APPROVE PRIOR TO INSTALL

7. ALL DOWNLIGHTS, WALL WASHERS, SPRINKLER HEADS, SPEAKERS, SENSORS, AND OTHER

CEILING-MOUNTED FIXTURES SHALL BE CENTERED ON THE 2'X2' OR 2'X4' MODULE

CREATED BY CEILING GRIDS AND CEILING TILE SCORE LINE, UNLESS OTHERWISE NOTED.

ARCHITECT SHALL BE NOTIFIED OF ANY CONFLICTS.

8. ALL LAMPS SHALL BE IDENTICAL FROM THE SAME MANUFACTURER. CONTRACTOR SHALL

REPLACE ALL NON-CONFORMING LAMPS. ALL LAMPS ARE TO BE SINGLE COLOR

TEMPERATURE UNO

9. ALL RECESSED FIXTURES SHALL BE SET FLUSH INTO CEILINGS

10. ALL DOWNLIGHTS, WALL WASHERS, SPRINKLER HEADS, ETC. SHALL ALIGN IN A STRAIGHT

LINE, UNO

11. ALL EMERGENCY LIGHTING TO BE UPGRADED TO MATCH BUILDING STANDARD/ TITLE 24

REQUIREMENTS, REFER TO ENGINEER DRAWINGS FOR EXACT LOCATIONS. REFER TO G.C.

FIRE DEPARTMENT NOTES FOR ADDITIONAL INFORMATION

12. ELECTRICAL SUBCONTRACTOR SHALL COORDINATE ANY ELECTRICAL OR LIGHTING

INSTALLATION INTO CABINETWORK (WHERE OCCURS) WITH CABINET SUBCONTRACTOR

AS REQUIRED

13. ELECTRICAL SUBCONTRACTOR SHALL COORDINATE ANY TELEPHONE/DATA/SECURITY

AND AUDIO-VISUAL REQUIREMENTS WITH THE CLIENT'S VENDORS AS REQUIRED

14. ELECTRICAL SUBCONTRACTOR SHALL PROVIDE ALL TEMPORARY LIGHTING AND

ELECTRICAL SERVICE FOR ALL TRADES AS REQUIRED THROUGHOUT DURATION OF

CONSTRUCTION

15. WHERE MORE THAN ONE SWITCH OCCURS IN THE SAME LOCATION, THEY SHALL BE

INSTALLED IN GANG TYPE BOX UNDER ONE COVER PLATE

16. ALL ELECTRICAL, DATA/TELEPHONE RECEPTACLES AND LIGHT FIXTURES SHALL BE

LOCATED WHERE DIMENSIONED ON PLANS. ALL FURNITURE FEEDS/J-BOXES TO BE

LOCATED PER DIMENSIONS PROVIDED BY CLIENT'S FURNITURE VENDOR OR KARDENT

17. ALL NEW OUTLETS ON COLUMNS (WHERE OCCURS) WILL BE CENTERED ON FACE, UNO

18. ALL ELECTRICAL, TELEPHONE/DATA RECEPTACLES SHALL BE INSTALLED VERTICALLY AT 18"

ABOVE FINISH FLOOR TO CENTER OF BOX. (MINIMUM 15" AFF TO BOTTOM OF BOX)

19. ALL THERMOSTATS AND CONTROL DEVICES SHALL BE A MAXIMUM OF 44" TO THE

CENTERLINE ABOVE FINISH FLOOR, UNLESS OTHERWISE NOTED. THERMOSTATS AND

LIGHTING CONTROLS OCCURRING WITHIN THE SAME ROOM SHALL BE LOCATED PER

TYPICAL INSTALLATION ELEVATION IN DRAWINGS.

20. ALL SIDE BY SIDE OUTLETS SHALL BE NO MORE THAN 6" ON CENTER, APART

21. PROVIDE NEW BLANK COVER PLATES FOR EXISTING RECEPTACLES NOT BEING USED WHEN

NOTED. COVER PLATES TO MATCH BUILDING STANDARD, AND/OR TO MATCHING

EXISTING, UNLESS OTHERWISE NOTED. CONFIRM WITH ARCHITECT PRIOR TO

INSTALLATION

22. RECEPTACLES AT BACK TO BACK LOCATIONS ARE TO BE STAGGERED

23. RECEPTACLES OCCURRING ON MILLWORK OR OTHER FINISH PANELS SHALL BE INSTALLED

FLUSH WITH FACE OF MILLWORK, OR FINISHED PANEL

24. TELEPHONE/DATA RECEPTACLES SHALL CONSIST OF A 2-GANG BOX WITH A PULL STRING

AND 3/4 " CONDUIT, STUBBED 6" ABOVE CEILING, UNO

25. ALL DIMENSIONS ON THE POWER AND SIGNAL PLAN ARE ON CENTER LINE AS INDICATED,

UNO

1. PROVIDE AND INSTALL NEW CEILING SYSTEM IN DESIGNATED AREAS AS SHOWN

ON THE REFLECTED CEILING PLAN

2. REVIEW ALL CEILING HEIGHTS AND CEILING PLENUM CONDITIONS WITH

SUBCONTRACTORS FOR CLEARANCE OF DUCTWORK, LIGHTING AND OTHER

OBSTRUCTIONS TO ASSURE THE FINISHED CEILING HEIGHT SHOWN ON

DRAWINGS IS ACHIEVABLE AND CONTINUOUS. ANY DISCREPANCIES SHALL BE

BROUGHT TO ARCHITECT'S ATTENTION PRIOR TO FINAL PRICING

3. CEILING HEIGHTS SHALL BE AS SHOWN ON DRAWINGS AND DETAILS. ANY

DEVIATION FROM HEIGHTS SHOWN BASED UPON EXISTING FIELD CONDITIONS

SHALL BE SUBMITTED TO ARCHITECT FOR REVIEW PRIOR TO START OF WORK IN

QUESTION, OR RELATED WORK

6. CLOSELY COORDINATE CEILING SUBCONTRACTOR'S WORK WITH OTHER

SUBCONTRACTORS AND CLIENT VENDORS WHEREVER THEIR RESPECTIVE WORK IS

CONTIGUOUS

7. PROVIDE AND INSTALL ALL CEILING ACCESS PANELS IN GYPSUM BOARD CEILINGS

AS REQUIRED FOR MECHANICAL, ELECTRICAL AND PLUMBING ACCESS PER LOCAL

CODES, WHETHER INDICATED ON DRAWINGS OR NOT. COORDINATE LOCATIONS

SIZE AND TYPE WITH KARDENT PRIOR TO INSTALLATION

8. PRIOR TO CLOSING UP ANY CEILING, ALL PLENUM SYSTEMS (HVAC, PLUMBING,

ELECTRICAL, ETC.) SHALL BE INSPECTED AND WHERE REQUIRED, TESTED BY

CONTRACTOR'S ENGINEERS, TO ENSURE THEIR PROPER INSTALLATION AND

FUNCTION

9. CEILINGS IN CLOSETS SHALL BE OF THE SAME HEIGHTS AND CONSTRUCTION AS

THAT OF ADJOINING SPACE, UNO

10. THE GENERAL CONTRACTOR SHALL PROVIDE CUT-OUTS AND OTHER SPECIAL

PROVISIONS IN ACOUSTICAL WORK AS REQUIRED FOR LIGHT FIXTURES, REGISTERS,

DIFFUSERS AND OTHER INSERTED ITEMS

11. SUSPENDED CEILINGS (WHERE OCCURS) SHALL BE INSTALLED OR CONSTRUCTED

IN ACCORDANCE WITH STATE AND LOCAL CODES AND ASCE 7-05

12. ALL FIRE SPRINKLERS (WHERE OCCURS) IN DRYWALL CEILING AREAS SHALL HAVE

CONCEALED HEAD ASSEMBLIES. COLOR OF TRIM SHALL MATCH ADJACENT CEILING

FINISH

13. CABLING TO BE PLENUM RATED AND SUSPENDED FROM THE STRUCTURE ABOVE.

CABLING MAY NOT REST ON CEILING GRID OR BE ATTACHED TO ANY OTHER

ELEMENTS ABOVE THE CEILING GRID. G.C. TO PROVIDE PULL STRING & OUTLET

14. FASCIAS OR ANY BREAK IN THE CEILING HEIGHTS SHALL BE AS SHOWN ON

DRAWINGS AND SHALL BE FORMED OF GYPSUM WALLBOARD ON METAL FRAMING

UNO

1. ALL EXISTING WINDOW COVERINGS SHALL BE INSPECTED BY THE CONTRACTOR AND

ALL INOPERABLE OR DAMAGED CONDITIONS SHALL BE REPAIRED OR REPLACED

2. ALL EXISTING WINDOW COVERINGS SHALL BE PROTECTED THROUGHOUT THE

DURATION OF DEMOLITION AND CONSTRUCTION

3. PRIOR TO INSTALLATION OF FLOORING AND WINDOW COVERINGS, GENERAL

CONTRACTOR SHALL MAINTAIN THE SPACE IN BROOM CLEAN CONDITION WHETHER

OR NOT INSTALLATION OF FLOORING AND WINDOW COVERING ARE THE

RESPONSIBILITY OF THE CONTRACTOR

4. PROVIDE NEW BUILDING STANDARD WINDOW COVERINGS AT ALL EXTERIOR

WINDOWS, UNO

1. SUBMIT THREE (3) SAMPLES OF EACH FINISH TO KARDENT FOR REVIEW INCLUDING

SEAMING/PATTERN LAYOUTS AS APPLICABLE PRIOR TO PURCHASE AND

INSTALLATION

2. ALL FINISHES SHALL BE BID AS SPECIFIED, ANY SUBSTITUTIONS MUST BE APPROVED

BY KARDENT PRIOR TO SUBMISSION OF BID

3. ALL INTERIOR FINISHES SHALL MEET LOCAL AND STATE CODES, THE CONTRACTOR

SHALL NOTIFY KARDENT IMMEDIATELY UPON DISCOVERY OF NON COMPLIANT

FINISHES

4. ALL FINISHES SHALL BE INSPECTED UPON ARRIVAL TO THE JOB SITE FOR DEFECTS

AND DYE LOT CONSISTENCY. NOTIFY KARDENT OF ANY DEFECT PRIOR TO

INSTALLATION

5. ALL FINISHES SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS

6. ALL SURFACES SHALL BE PREPARED APPROPRIATELY TO RECEIVE SPECIFIED FINISHES

7. ENSURE ALL HOLES, SCRAPES AND GOUGES HAVE BEEN PATCHED AND PREPARED TO

RECEIVE NEW FINISHES

8. PROTECT NEW INSTALLED FINISHES FROM DAMAGE THAT MAY OCCUR BY OTHER

TRADES DURING DEMOLITION OR CONSTRUCTION

9. EXAMINE ALL FINISH SURFACES AFTER COMPLETION OF WORK AND PROCEED WITH

TOUCH UP AS REQUIRED

10. ALL FINISHES SHALL BE LEFT IN "LIKE NEW" CONDITIONS

11. IN SOUND RATED ROOMS, ALL WALL AND FLOOR PENETRATIONS FOR PIPES DUCTS

AND OUTLETS SHALL BE SEALED WITH AN ACOUSTIC SEALANT, AND CONCEALED OR

RECESSED FIXTURES SHALL BE COVERED OR BACKED WITH A SOUND ATTENUATION

BLANKET.

12. REFER TO FIRE DEPARTMENT NOTES ON SHEET A-0.1 FOR ADDITIONAL

REQUIREMENTS

1. SUBMIT THREE (3) PAINT DRAW DOWN SAMPLES (8.5"X11") OF EACH FINISH FOR

KARDENT TO REVIEW PRIOR TO PURCHASE AND INSTALLATION. PROVIDE SEAMING

DIAGRAM AND/OR PATTERN LAYOUT (WHERE OCCURS).

2. WALLCOVERING SUBCONTRACTOR TO REVIEW PERTINENT WALL PATCHING NOTES

IN SECTION 3.01, PATCHING AND CUTTING ON THIS SHEET, AND ENSURE SURFACES

ARE PROPERLY PREPPED PRIOR TO INSTALLING OF NEW MATERIALS AND/OR FINISHES.

3. INSTALL WALLCOVERINGS AS PER MANUFACTURER'S INSTALLATION SPECIFICATIONS,

WHERE DESIGNATED. ALL WALLCOVERINGS SHALL BE SMOOTH, WITH NO WRINKLES,

BUBBLES OR LOOSE EDGES, ALL PASTE AND BRUSH MARKS SHALL BE THOROUGHLY

REMOVED. WALLCOVERING ADJOIN WOOD OR METAL TRIM SHALL BE CUT STRAIGHT

AND SQUARE.

4. WALLS SHALL INCLUDE SURFACES FROM FLOOR TO CEILING, INCLUDING PILASTERS,

FASCIAS, AND ALL VERTICAL SURFACES NOT INCLUDED IN CEILING, UNO.

5. ALL WALLS AND CEILINGS SHALL BE PROPERLY PREPARED, PATCHED, SANDED, ETC.

TO PROVIDE A LEVEL 4 FINISH. PROVIDE LEVEL 5 FINISH ONLY WHERE INDICATED ON

PLAN.

6. ALL OPEN PORES IN WOOD SHELVING AND PAINTED DOORS SHALL BE FILLED AND

SHALL RECEIVE PRIMING, SANDING AND TWO FULL FINISH COATS FREE OF BRUSH

MARKS, UNLESS OTHERWISE NOTED. GLOSS FINISH PER SCHEDULE.

7. REMOVE ALL ELECTRICAL SWITCH AND RECEPTACLE PLATES, SURFACE HARDWARE,

ETC., AND PROTECT EXPOSED AREAS PRIOR TO PAINTING. REINSTALL OR REPLACE

ANY DAMAGED PLATES OR HARDWARE WHEN PAINTING HAS BEEN COMPLETED.

CONTRACTOR SHALL REMOVE ALL PAINT FROM SURFACES WHERE SPILLS, SPLASHES

OR SPLATTERS HAVE OCCURRED, INCLUDING BUT NOT LIMITED TO LIGHT FIXTURES,

DIFFUSERS, REGISTERS, ETC.

8. USE A LATEX BASE PAINT IN COLORS AND FINISHES SELECTED BY ARCHITECT.

PROPERLY PREPARE ALL SURFACES TO RECEIVE ONE (1) PRIMER COAT AND TWO (2)

FINISH COATS OF PAINT IN COLOR SELECTED BY ARCHITECT. INCLUDE ADDITIONAL

FINISH COATS AS REQUIRED TO ACHIEVE COLOR TO MATCH CONTROL SAMPLE.

9. UNEVENNESS IN EXISTING PARTITIONS SHALL BE SANDED OR CHIPPED AWAY AND

SURFACE PATCHED TO INSURE A PERFECTLY EVEN SURFACE.

10. EXAMINE ALL AREAS OF CONSTRUCTION AFTER COMPLETION OF WORK BY ALL

TRADES (INCLUDING TELEPHONE INSTALLATION, FLOORING, ETC.) AND COMPLETE

ALL NECESSARY "TOUCH-UP" PAINTING AND /OR PATCHING PRIOR TO SCHEDULING

A PUNCH WALK.

11. IT IS THE INTENT OF THE DRAWINGS THAT ALL EXPOSED SURFACES RECEIVE FINISHES

UNLESS SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS. ANY SURFACES

WHICH DO NOT HAVE A SPECIFIC FINISH NOTED, OR ARE NOTED TO REMAIN

UNFINISHED, SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND

FINISHED PER ARCHITECT'S INSTRUCTIONS.

12. TREAT JOINTS AND FASTENERS IN GYPSUM BOARD IN ACCORDANCE WITH GYPSUM

ASSOCIATION GA-214

13. RE-PAINT ALL EXISTING METAL SURFACES, INCLUDING HOLLOW METAL DOOR FRAME,

FIRE EXTINGUISHER CABINETS, ACCESS PANELS, ETC.

14. WHEN PAINTING PUBLIC CORRIDORS, ELEVATOR LOBBIES, STAIRWAYS, COMMON

AREA RESTROOMS, ETC. CHECK WITH BUILDING MANAGEMENT FOR BUILDING

STANDARD FINISH SPECIFICATIONS AND IN-STOCK AVAILABILITY

15. CONTRACTOR TO PREPARE ALL WALLS (NEW & EXISTING) TAPED, SANDED AND

SMOOTH TO RECEIVE NEW APPROVED WALL FINISH

1. SUBMIT THREE (3) FULL SIZE SAMPLES AND A DIMENSIONED SEAMING DIAGRAM TO

KARDENT FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION OF SPECIFIED FLOOR

COVERING AND BASIC MATERIALS

2. REVIEW PERTINENT FLOOR PATCHING & CUTTING NOTES ON THE DRAWINGS. ALL

SURFACES TO BE PREPPED PER MANUFACTURER'S INSTRUCTIONS AND

SPECIFICATIONS. ENSURE SURFACES ARE PROPERLY PREPPED PRIOR TO INSTALLING

NEW MATERIALS AND/OR FINISHES

3. ANY MAJOR AND MINOR FLOOR PREPARATION IS THE RESPONSIBILITY OF THE

CONTRACTOR. FILL, SAND, AND LEVEL AS REQUIRED PRIOR TO INSTALLATION FINISH

MATERIAL TO PROVIDE A FLUSH AND EVEN SUBSTRATE. ALL SELF LEVELING

COMPOUNDS USED SHALL BE CEMENTITIOUS. ALL IMPERFECTIONS AND SLIGHT

DEPRESSIONS IN THE FLOOR SURFACE SHALL BE SKIM COATED

4. ALL NEW FLOORING IS TO BE PROVIDED AND INSTALLED BY GENERAL

CONTRACTOR AND SHALL BE AS SPECIFIED ON THE DRAWINGS, UNO

5. FLOORING TILES SHALL BE LAID IN SQUARE PATTERN WITH COURSES, PARALLEL TO

WALLS, UNO

6. TILES SHALL BE SECURELY CEMENTED AND SHALL BE LAID WITH TIGHT JOINTS. THE

ADHESIVE USED FOR CEMENTING TILE SHALL BE APPLIED FAR ENOUGH IN ADVANCE

OF THE SETTING TO PERMIT THE ADHESIVE TO REACH ITS INITIAL SET, BUT NOT ITS

FINAL SET. ALL STONE AND TILE FLOORING SHALL BE INSTALLED OVER CRACKED

ISOLATION /WATERPROOFING MEMBRANE. CONTRACTOR TO TEST SLAB FOR

MOISTURE PRIOR TO INSTALLATION OF RESILIENT FLOORING, AND INSTALL PER

MANUFACTURER'S INSTRUCTIONS

7. AREAS BEING SURFACED SHALL BE CLOSED TO TRAFFIC AND OTHER WORK DURING

THE LAYING OF FLOORING. STONE FLOORS SHALL BE COVERED AFTER INSTALLATION

FOR PROTECTION

8. CLEAN, REMOVE ALL SPOTS OF ADHESIVE AND SURFACES STAINS AND SCRAPS;

CARTONS AND CONTAINERS SHALL BE REMOVED FROM THE BUILDING UPON

COMPLETION OF WORK

9. APPLY TWO APPLICATIONS OF AN APPROVED NON-SLIP WAX OVER RESILIENT TILE

FLOOR, WHICH IS TO BE THOROUGHLY MACHINE BUFFED AND LEFT IN A

CONDITION SATISFACTORY TO THE CLIENT REPRESENTATIVE

10. PROVIDE AND MAINTAIN ADEQUATE PROTECTION FOR ALL FLOORING WORK FOR

THE DURATION OF THE CONTRACT AND REMOVE ALL PROTECTION PRIOR TO

PUNCHLIST. ONLY CLIENT APPROVED CARPET PROTECTION SHALL BE USED,

ENSURING NO RESIDUE WILL REMAIN UPON REMOVAL

11. COORDINATE ALL FLOORING SUBCONTRACTORS INVOLVED TO ENSURE FLUSH

INSTALLATION OF VARYING FLOOR MATERIALS SPECIFIED ON THE DRAWINGS. ALL

TRANSITION METHODS TO BE APPROVED BY ARCHITECT PRIOR TO INSTALLATION

12. PROVIDE REDUCER STRIP OR METAL TRANSITION STRIP WHERE MATERIAL

TRANSITIONS OCCUR.