Quality Assurance Special Instructions.pdf
PDF 86 KB Posted
- Attached to
- B-1B Power Take-Off (PTO) Shaft Repair IDIQ
- Solicitation number
- FA825226R0613
About this file
This is an AFMC Form 807, Recommended Quality Assurance Provisions and Special Inspection Requirements, issued by the Air Force on 14 April 2025.
The document establishes quality assurance and inspection requirements for a part identified by National Stock Number 2835015373778RP. Inspection occurs at the source, with acceptance also at the source per DFARS 246.402. The contract quality requirements specify production lot testing in accordance with ANSI/ASQ Z1.4 using General Inspection Level II and an Acceptance Quality Limit of 1.0. All shaft dimensions of the part referenced in drawing 3609195-1 must be inspected. Test report requirements may be satisfied by submitting lot inspection results to the local DCMA representative, or if unavailable, to 419 SCMS/GUEA. The item manager is Justin T. Ross (801-775-4959) and the equipment specification contact is Troy Rackham (801-586-3675). The technical authority is Taylor D. Olpin from 419 SCMS/GUEA (801-775-2073). The quality pre-award survey is not required as this is for a previous source. The document includes a statement confirming the requirement does not mandate the use of Class I ozone-depleting substances, and notes that quality provisions will not be downgraded without technical authority coordination.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Special Packaging Instructions.pdf | ||
| RDL_REPORT.pdf | ||
| ITMDESC_REPORT.pdf | ||
| CDRL_A005.pdf | ||
| FA825226R0613.pdf | ||
| PWS.pdf | ||
| CDRL B1 PTO.pdf | ||
| CAV AF Reporting Requirements.pdf | ||
| PKGRQMT_REPORT.pdf | ||
| QASP.pdf | ||
| Ombudsman.pdf | ||
| GFPFA8252R0613_1 Year 1.pdf | ||
| IUID.pdf |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RECOMMENDED QUALITY ASSURANCE PROVISIONS
AND SPECIAL INSPECTION REQUIREMENTS
1. PR / MIPR NUMBER
2. NATIONAL STOCK NUMBER
2835015373778RP
3. POINT OF INSPECTION
SOURCE DESTINATION
X
SEE DFARS 246.402
4. POINT OF ACCEPTANCE
SOURCE DESTINATION
X
5. ITEM MANAGER / PHONE
Ross, Justin T / 801-775-4959
6. EQUIPMENT SPEC / PHONE
Rackham, Troy / 801-586-3675
7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS
CERTIFICATE OF CONFORMANCE
FAR 52.246-15
CONTRACT RESPONSIBILITY FOR INSPECTION
FAR 52.246-15
STANDARD INSPECTION
FAR 52.246-2,-3,-4,-5 OR -6 AS APPLICABLE TO CONTRACT
HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS FAR 52.246-11
COMMERCIAL ITEM INSPECTION
FAR 52.212-4
X OTHER (Describe in Block 8)
8. REMARKS
Hull, Carter ANAME: 14 APR 2025DATE:
Perform production lot testing in accordance with ANSI/ASQ Z1.4, using General Inspection Level II and an Acceptance Quality Limit of 1.0. Inspect all shaft dimensions of part, per drawing 3609195-1. Test Report Required may be satisfied by sending lot inspection results to local DCMA representative. If a local DCMA representative is not available, send results to 419 SCMS/GUEA.
Olpin, Taylor DNAME: 11 JAN 2023DATE:
Perform production lot testing in accordance with ANSI/ASQ Z1.4, using General Inspection Level II and an Acceptance Quality Limit of 1.0. Inspect all shaft dimensions of part, per drawing 3609195-1. Test Report Required may be satisfied by sending lot inspection results to local DCMA representative. If a local DCMA representative is not available, send results to 419 SCMS/GUEA.
8a. OZONE DEPLETING SUBSTANCES (ODS)
X STATEMENT
"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN
ONLY BE MET BY THE USE OF A CLASS I ODS."
WAIVER (SEE DAFFARS 5323.8)
NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.
9. QUALITY PRE-AWARD SURVEY
YES NEW SOURCE
X PREVIOUS SOURCEX NO
AFMC PARTICIPATION
RECOMMENDED
10. CODES
A. I&A
B. CQR
I
11. SIGNATURE OF TECHNICAL AUTHORITY
Olpin, Taylor D
ORGANIZATION / SYMBOL
419 SCMS / GUEA
PHONE
801-775-2073 / 775-2073
DATE
14 APR 2025
Page 1 of 1Prescribed by: AFMCI20-102 Version 4Generated by PRPS using Jasper Reports on 27 May 2025