This is an AFMC Form 807, Recommended Quality Assurance Provisions and Special Inspection Requirements, issued by the Air Force on 14 April 2025.

The document establishes quality assurance and inspection requirements for a part identified by National Stock Number 2835015373778RP. Inspection occurs at the source, with acceptance also at the source per DFARS 246.402. The contract quality requirements specify production lot testing in accordance with ANSI/ASQ Z1.4 using General Inspection Level II and an Acceptance Quality Limit of 1.0. All shaft dimensions of the part referenced in drawing 3609195-1 must be inspected. Test report requirements may be satisfied by submitting lot inspection results to the local DCMA representative, or if unavailable, to 419 SCMS/GUEA. The item manager is Justin T. Ross (801-775-4959) and the equipment specification contact is Troy Rackham (801-586-3675). The technical authority is Taylor D. Olpin from 419 SCMS/GUEA (801-775-2073). The quality pre-award survey is not required as this is for a previous source. The document includes a statement confirming the requirement does not mandate the use of Class I ozone-depleting substances, and notes that quality provisions will not be downgraded without technical authority coordination.

View the file

Other files

File Type Posted
Special Packaging Instructions.pdf PDF
RDL_REPORT.pdf PDF
ITMDESC_REPORT.pdf PDF
CDRL_A005.pdf PDF
FA825226R0613.pdf PDF
PWS.pdf PDF
CDRL B1 PTO.pdf PDF
CAV AF Reporting Requirements.pdf PDF
PKGRQMT_REPORT.pdf PDF
QASP.pdf PDF
Ombudsman.pdf PDF
GFPFA8252R0613_1 Year 1.pdf PDF
IUID.pdf PDF
Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RECOMMENDED QUALITY ASSURANCE PROVISIONS

AND SPECIAL INSPECTION REQUIREMENTS

1. PR / MIPR NUMBER

2. NATIONAL STOCK NUMBER

2835015373778RP

3. POINT OF INSPECTION

SOURCE DESTINATION

X

SEE DFARS 246.402

4. POINT OF ACCEPTANCE

SOURCE DESTINATION

X

5. ITEM MANAGER / PHONE

Ross, Justin T / 801-775-4959

6. EQUIPMENT SPEC / PHONE

Rackham, Troy / 801-586-3675

7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS

CERTIFICATE OF CONFORMANCE

FAR 52.246-15

CONTRACT RESPONSIBILITY FOR INSPECTION

FAR 52.246-15

STANDARD INSPECTION

FAR 52.246-2,-3,-4,-5 OR -6 AS APPLICABLE TO CONTRACT

HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS FAR 52.246-11

COMMERCIAL ITEM INSPECTION

FAR 52.212-4

X OTHER (Describe in Block 8)

8. REMARKS

Hull, Carter ANAME: 14 APR 2025DATE:

Perform production lot testing in accordance with ANSI/ASQ Z1.4, using General Inspection Level II and an Acceptance Quality Limit of 1.0. Inspect all shaft dimensions of part, per drawing 3609195-1. Test Report Required may be satisfied by sending lot inspection results to local DCMA representative. If a local DCMA representative is not available, send results to 419 SCMS/GUEA.

Olpin, Taylor DNAME: 11 JAN 2023DATE:

Perform production lot testing in accordance with ANSI/ASQ Z1.4, using General Inspection Level II and an Acceptance Quality Limit of 1.0. Inspect all shaft dimensions of part, per drawing 3609195-1. Test Report Required may be satisfied by sending lot inspection results to local DCMA representative. If a local DCMA representative is not available, send results to 419 SCMS/GUEA.

8a. OZONE DEPLETING SUBSTANCES (ODS)

X STATEMENT

"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN

ONLY BE MET BY THE USE OF A CLASS I ODS."

WAIVER (SEE DAFFARS 5323.8)

NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.

9. QUALITY PRE-AWARD SURVEY

YES NEW SOURCE

X PREVIOUS SOURCEX NO

AFMC PARTICIPATION

RECOMMENDED

10. CODES

A. I&A

B. CQR

I

11. SIGNATURE OF TECHNICAL AUTHORITY

Olpin, Taylor D

ORGANIZATION / SYMBOL

419 SCMS / GUEA

PHONE

801-775-2073 / 775-2073

DATE

14 APR 2025

Page 1 of 1Prescribed by: AFMCI20-102 Version 4Generated by PRPS using Jasper Reports on 27 May 2025

AFMC FORM 807, 20230130 PREVIOUS EDITION IS OBSOLETE