QP 11-1-9771-1 T-11R SP Extractor Assembly 17 Nov 2022.pdf

PDF 97 KB Posted

Attached to
W56HZV23R0115 Solicitation T-11 Reserve Spares: QPL Items NSN:1670-01-696-3468, 1670-01-696-3150, 1670-01-696-3467, 1670-01-696-3640
Solicitation number
W56HZV23R0115
Issued by

About this file

This document outlines quality assurance provisions for an extractor assembly component to be procured by the Department of the Army Materiel Command. Inspections will include a first article review examining materials, construction, and dimensions to ensure conformance with specifications. Production lots will be sampled according to ANSI/ASQ Z1.4 at an S-3 inspection level and AQL of 1.0, with any sample unit containing one major defect or more than one minor defect deemed nonconforming. Defect classifications will follow MIL-STD-849 or be specified by the procuring activity. This component is related to solicitation W56HZV23R0115 for T-11 reserve spares including four national stock numbers, issued by the TACOM Life Cycle Management Command.

View the file

Other files

Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

17 Nov 2022

Quality Assurance Provisions For

Extractor Assembly, T-11R Single Pin

MIL-DTL-6645

P/N 11-1-9771-1

1. First Article.

1.1 Inspection. Inspect in accordance with the First Article requirements of paragraph 6.2, subparagraph (d.) of MIL-DTL-6645. These requirements include a component and material inspection, in-process inspection, examination of the item to ensure conformance to the visual, construction, manufacturing and dimensional requirements of 11-1-9771, its associated drawings and specifications.

1.2 Acceptance/Rejection. Any defect, nonconformance or test failure shall be cause for rejection of the First Article.

2. Conformance/Lot Inspection.

2.1 Sampling. Sampling for the inspection shall be performed in accordance with ANSI/ASQ Z1.4. The lot size shall be expressed in units of extractor assemblies. The sample unit shall be one extractor assembly. The Inspection Level shall be S-3. The Acceptable Quality Limit (AQL) shall be 1.0.

2.2 Inspection. Inspect in accordance with conformance inspection requirements of paragraph 4.4 of MIL-DTL-6645 including material, visual, and dimensional examinations as specified in 11-1-9771 and Table VII of MIL-STD-849.

2.3 Acceptance/Rejection. Any sample unit having one major defect or more than one minor defect shall be considered a nonconforming unit. Major and minor defects are classified in Table VII of MIL-STD-849.

3. Classification of Defects. Classification of nonconformities/defects not specified in MIL-STD-849 for the FAI and Conformance Inspections shall be specified by the procuring activity.

DISTRIBUTION STATEMENT A

THIS DOCUMENT IS APPROVED FOR PUBLIC RELEASE, DISTRIBUTION IS UNLIMITED.

File details come from the government source that posted it. Updated .