QP 11-1-9609-1 Pack Tray T-11R SP 17 Nov 2022.pdf
PDF 98 KB Posted
- Solicitation number
- W56HZV23R0115
About this file
This document outlines quality assurance provisions for the assembly of Pack Tray T-11R Single Pin units. Inspection requirements include a first article inspection verifying conformance to drawings, specifications and manufacturing requirements, with any defects constituting rejection. Conformance inspections will sample lot sizes of assemblies using ANSI/ASQ Z1.4 level S-3 inspection, examining materials, visual characteristics and dimensions according to the drawings and MIL-STD-849 Table VI, considering any sample with one major defect or more than three minor defects as nonconforming. The Army Materiel Command TACOM Life Cycle Management Command solicitation W56HZV23R0115 seeks T-11 Reserve Spares including the items covered by these quality provisions: NSNs 1670-01-696-3468, 1670-01-696-3150, 1670-01-696-3467, and 1670-01-696-3640.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
17 Nov 2022
Quality Assurance Provisions For
Pack Tray Assembly, T-11R Single Pin
MIL-DTL-6645
P/N 11-1-9609-1
1. First Article.
1.1 Inspection. Inspect in accordance with the First Article requirements of paragraph 6.2, subparagraph (d.) of MIL-DTL-6645. These requirements include a component and material inspection, in-process inspection, examination of the assembly to ensure conformance to the visual, construction, manufacturing and dimensional requirements of 11-1-9609, its associated drawings and specifications.
1.2 Acceptance/Rejection. Any defect or nonconformance shall be cause for rejection of the First Article.
2. Conformance/Lot Inspection.
2.1 Sampling. Sampling for the inspection shall be performed in accordance with ANSI/ASQ Z1.4. The lot size shall be expressed in units of Pack Tray Assemblies. The Inspection Level shall be S-3. The sample unit shall be one Pack Tray Assembly.
2.2 Inspection. Inspect in accordance with the conformance inspection requirements of paragraph 4.4 of MIL-DTL-6645 including material, visual and dimensional examinations as specified in 11-1-9609, its associated drawings and Table VI of MIL-STD-849.
2.3 Acceptance/Rejection. Any sample unit having one major defect or more than three minor defects shall be considered a nonconforming unit. Major and minor defects are classified in Table VI of MIL-STD-849. The Acceptable Quality Limit (AQL) shall be 1.0.
3. Classification of Defects. Classification of nonconformities/defects not specified in MIL-STD-849 for the FAI and Conformance Inspections shall be specified by the procuring activity.
DISTRIBUTION STATEMENT A
THIS DOCUMENT IS APPROVED FOR PUBLIC RELEASE, DISTRIBUTION IS UNLIMITED.