PWS Attachment 3 Performance Requirements_10 Dec 2021.docx

DOCX document 22 KB Posted

Attached to
HVAC Equipment and System Maintenance Services IDIQ (NSWCPD)
Solicitation number
N6449822R5001
Issued by

View the file

Other files

File Type Posted
N6449822R5001 Amendment 0002.pdf PDF
N6449822R5001 Amendment 0001.pdf PDF
Attachment 8 Past Performance Questionnaire (PPQ).doc DOC document
PWS Attachment 2 HVAC_SYS EQUIP INVENTORY_25 MAY 2022.xlsx XLSX spreadsheet
CDRL A004 - Contractors Quality Management Plan_25 June 2021_signed.pdf PDF
CDRL A003 - Contractors Personnel Roster_25 June 2021_signed.pdf PDF
CDRL A002 - Contractors Maintenance Program Plan_25 June 2021_signed.pdf PDF
PWS Attachment 1 HVAC_PNBC Site Map_10 Dec 2021.pdf PDF
Attachment 8 Past Performance Questionnaire (PPQ).doc DOC document
N6449822R5001.pdf PDF
CDRL A001 - Contract Status Report_25 June 2021_signed.pdf PDF
CDRL A009 - Asbestos Containing Material Report_5 May 2022_signed.pdf PDF
CDRL A005 - Accident Prevention Plan_25 June 2021_signed.pdf PDF
PWS Attachment 5 NSWCPD COVID 19 ENTRY SCREENING ASSESSMENT.docx DOCX document
CDRL A008 - OSHA Citations and Violations Corrective Action Report_5 May 2022_signed.pdf PDF
Attachment 7 Price Proposal Form.xlsx XLSX spreadsheet
PWS Attachment 4 UFC-3-430-07 Testing and Certification of Boilers.pdf PDF
CDRL A007 - Accident Reports_25 June 2021_signed.pdf PDF
CDRL A006 - Activitiy Hazard Analysis_25 June 2021_signed.pdf PDF
PWS Attachment 6 CTF COVID Screening Questionnaire.pdf PDF
Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

HVAC Maintenance and Repair Contract PWS Attachment 3 10 December 2021

SOW Performance Requirements

Performance Objective
Standard
Method of Surveillance
Acceptable Threshold

Preventative Maintenance (PM) Services, Reference Section 3.4.1 3.4.2 and 3.4.3

All HVAC equipment fully operational at all times, unless otherwise scheduled and approved by the COR. Provide a detailed report/checklist within forty-eight (48) hours of completion.
100% Inspection

HVAC equipment PMs are completed for each building. 97% completed upon initial inspection and 100% are completed upon final inspection. Reports are submitted within forty-eight (48) hours 95% of the time. Reports are timely and accurate.

Timely and responsive to all Diagnostic service requests, and Corrective Maintenance Level I calls, Reference Sections 3.4.1.3 through 3.4.1.9

Repairs, general and emergency, are made in a timely manner; the contractor shall respond on the same day for requests submitted before 1200 (noon) and the next day for requests received after 1200; customers are informed of the expected repair time. Response and repairs are made within the specified time of twenty four (24) hours.
100% Inspection

Service calls are responded to on-time 90% of the time. Repairs are completed and HVAC equipment is returned to service on-time 95% of the time.

Submission of timely and accurate maintenance and repair reports, Reference Sections 3.4.1.9
Accurate and complete reports are delivered on schedule.

100% Inspection

100% of reports are timely and accurate.

HVAC Water Testing and Treatment, Boiler Water Testing and Treatment and Annual Boiler Testing and Certification and Reports, Reference Section 3.4.2.2, 3.4.2.3, 3.2.4.4, 3.4.2.5 and 3.4.4

HVAC equipment, water testing and treatment and boiler certifications are completed on schedule. Accurate and complete reports are delivered on schedule.

100% Inspection

100% of the equipment passes and receives certification for use. 100% of reports are timely and accurate.

Service Interruptions, Reference Section 3.3.5

Contractor shall schedule and perform service to the HVAC equipment in a manner that minimally disrupts building occupants and government business. Contractor notifies COR prior to taking equipment out of service.
100% Inspection

HVAC equipment downtime is not to exceed one time per piece of equipment per quarter. Downtime shall not exceed two (2) consecutive days.

Corrective Maintenance Level II Repairs, Reference Sections 3.4.5
Work is accomplished in accordance with the requirements of the scope of work. The HVAC equipment is operational and does not present a danger to personnel or equipment.
100% Inspection
95% of the work is completed upon initial inspection and 100% of work is completed upon final inspection.