NSWC EQ LIST
| SOW ATTACHMENT 2A OF HVAC MAINTENANCE AND REPAIR CONTRACT | 25/May/2022 | |||||||||
| NSWCPD EQUIPMENT INVENTORY | ||||||||||
| NOTE: This equipment list is subject to change due to system upgrades or equipment replacement. | ||||||||||
| BLDG | ID NO | DESCRIPTION | MFG MODEL | LOCATION | COOLING | TYPE | HP/MBH/CFM/Ton | QTY | ||
| 4 | 4-1 | 300 TON CHILLER | YORK | MECH RM E | TOWER | Centrifugal | 300 ton | 1 | ||
| 4 | 4-2 | 300 TON CHILLER | YORK | MECH RM W | TOWER | Centrifugal | 300 ton | 1 | ||
| 4 | 4-10 | 150 TON CHILLER | CARRIER 30RBX 15064-LNL3C | ROOF EAST SIDE | Air | Scroll | 150 ton | 1 | ||
| 4 | *4-1-1 | *AHU - 1 | YORK | PENTHOUSE | 45KCFM / 813 MBH CW Coil | 1 | ||||
| 4 | *4-1-2 | *AHU - 2 | YORK | PENTHOUSE | 46KCFM / 678 MBH CW Coil | 1 | ||||
| 4 | *4-1-3 | *AHU - 3 | YORK | PENTHOUSE | 30.7KCFM / 658 MBH CW Coil | 1 | ||||
| 4 | *4-1-4 | *AHU - 4 | YORK | PENTHOUSE | 18.5KCFM / 471 MBH CW Coil | 1 | ||||
| 4 | *4-1-5 | *AHU - 5 | YORK | PENTHOUSE | 30KCFM / 686 MBH CW Coil | 1 | ||||
| 4 | *4-1-6 | *AHU - 6 | YORK | PENTHOUSE | 1.8KCFM / 77 MBH CW Coil | 1 | ||||
| 4 | *4-3 | *14 TON COMP RM ACU | LIEBERT | 2ND FL UPS ROOM | GLYCOL | 14 ton | 1 | |||
| 4 | *4-4 | *14 TON COMP RM ACU | LIEBERT | 2ND FL COM RM E | GLYCOL | 14 ton | 1 | |||
| 4 | *4-5 | *14 TON COMP RM ACU | LIEBERT | 2ND FL COM RM W | GLYCOL | 14 ton | 1 | |||
| 4 | 4-1-24 | COOLING TOWER | BAC VXT | PENTHOUSE | 300 Ton | 1 | ||||
| 4 | 4-1-25 | COOLING TOWER | BAC VXT | PENTHOUSE | 300 Ton | 1 | ||||
| 4 | *4-1-1A | *LP Compressed Air System | Devair Compressor - CJ0-090301 - Dual Heads | PENTHOUSE | 1 | |||||
| 4 | *4-1-1A | *LP Compressed Air System | BelAir Dryer - AMD15-1 | PENTHOUSE | 15 SCFM | 1 | ||||
| 4 | *4-1-1A | *LP Compressed Air System | SPX HANKiSON Desiccant Dryer - DHW-25 | PENTHOUSE | 1 | |||||
| 4 | 4-1-1P | 20 HP TWR PMP | ALLIS CHAMBERS | PENTHOUSE | 20 hp | 1 | ||||
| 4 | 4-1-2P | 20 HP TWR PMP | ALLIS CHAMBERS | PENTHOUSE | 20 hp | 1 | ||||
| 4 | 4-1-3P | 20 HP TWR PMP | ALLIS CHAMBERS | PENTHOUSE | 20 hp | 1 | ||||
| 4 | 4-1-4P | 15 HP CW PMP | ALLIS CHAMBERS | PENTHOUSE | 15 hp | 1 | ||||
| 4 | 4-1-5P | 15 HP CW PMP | ALLIS CHAMBERS | PENTHOUSE | 15 hp | 1 | ||||
| 4 | 4-1-6P | 15 HP CW PMP | ALLIS CHAMBERS | PENTHOUSE | 15 hp | 1 | ||||
| 4 | *4-1-7P | *5 HP DUAL TEMP | ALLIS CHAMBERS | PENTHOUSE | 5 hp | 1 | ||||
| 4 | *4-1-8P | *5 HP DUAL TEMP | ALLIS CHAMBERS | PENTHOUSE | 5 hp | 1 | ||||
| 4 | 4-1-9P | PRIMARY HW | Weinman | PENTHOUSE | 3 HP - 300 GPM | 1 | ||||
| 4 | 4-1-10P | PRIMARY HW | Weinman | PENTHOUSE | 3 HP - 300 GPM | 1 | ||||
| 4 | 4-1-11P | GLYCOL PMP | ALLIS CHAMBERS | PENTHOUSE | 3 HP - 190 GPM | 1 | ||||
| 4 | 4-1-12P | GLYCOL PMP | ALLIS CHAMBERS | PENTHOUSE | 3 HP - 190 GPM | 1 | ||||
| 4 | 4-1-13P | HW PMP | ALLIS CHAMBERS | PENTHOUSE | 3 HP | 1 | ||||
| 4 | 4-1-14P | HW PMP | ALLIS CHAMBERS | PENTHOUSE | 3 HP | 1 | ||||
| 4 | 4-1-15P | SEC. HW PMP | The Valley Pump Group | PENTHOUSE | 1 HP - 48 GPM | 1 | ||||
| 4 | 4-1-16P | SEC. HW PMP | Weinman | PENTHOUSE | 1 HP - 48 GPM | 1 | ||||
| 4 | *4-1-20P | *5 HP DUAL TEMP PMP | ALLIS CHAMBERS | PENTHOUSE | 5 HP | 1 | ||||
| 4 | *4-3-1P | *GLYCOL PUMP | Liebert - S3A | ROOF N PMP | 3 HP | 1 | ||||
| 4 | *4-4-1P | *GLYCOL PUMP | Liebert - S3A | ROOF CENTER PMP | 3 HP | 1 | ||||
| 4 | *4-5-1P | *GLYCOL PUMP | Liebert - S3A | ROOF S PMP | 3 HP | 1 | ||||
| 4 | *4-7-1P | *GLYCOL PUMP | AO Smith - CATH706 | ROOF | 2 HP | 1 | ||||
| 4 | *4-1-1 FC THRU *4-1-147FC | *FAN COIL UNITS | YORK | PERIMETER 1ST & 2ND FLOOR | ~ 1 Ton | 147 | ||||
| 4 | *4-1-148FC THRU *4-1-152FC | *FAN COIL UNITS | Indeeco 922U05000C | 1st FLOOR ENTRANCES | 1.5 Tons | 5 | ||||
| 4 | *4-1-153 FC | *FAN COIL UNIT | YORK | PERIMETER 2ND FL N/W ROOM 2151 | ~ 1 Ton | 1 | ||||
| 4 | *4-7 | *4 TON SPLIT SYS | SKIL-AIRE | 2ND FL UTILITY RM | GLYCOL | 4 ton | 1 | |||
| 4 | *4-7(DC) | *DRY COOLER | LIEBERT | ROOF | AIR | 4 Ton | 1 | |||
| 4 | *4-8 | *3 TON SPLIT SYS | SKIL AIRE | 1ST FL CNTR EAST | AIR | 3 ton | 1 | |||
| 4 | *4-8-1 | *AHU | SKIL AIRE | PHONE ROOM | 3 ton | 1 | ||||
| 4 | *4-9 | *3 TON SPLIT SYS | SKIL AIRE | 1ST FL CNTR EAST | AIR | 3 ton | 1 | |||
| 4 | *4-9-1 | *AHU | SKIL AIRE | BELL ROOM | 3 ton | 1 | ||||
| 4 | *4-11 | *4 TON DUCTLESS | CARRIER | ROOF | AIR | 4 ton | 1 | |||
| 4 | *4-11-1 | *CEILING AHU | CARRIER | MEZZ. COMP RM SUPPORT | 4 ton | 1 | ||||
| 4 | *4-12 | *4 TON DUCTLESS | CARRIER | ROOF | AIR | 4 ton | 1 | |||
| 4 | *4-12-1 | *CEILING AHU | CARRIER | MEZZ. COMP RM SUPPORT | 4 ton | 1 | ||||
| 4 | *4-13 | *1.5 TON SPLIT SYS | Fujitsu - AOU18RLXFW1 | SIPERNET RM MEZZ NORTH | AIR | 1.5 ton | 1 | |||
| 4 | *4-13-1 | *WALL HUNG AHU | Fujitsu | SIPERNET RM MEZZ NORTH | 1.5 ton | 1 | ||||
| 4 | *4-14 | *1.5 TON SPLIT SYS | MITSUBISHI | SIPERNET RM MEZZ NORTH | AIR | 1.5 ton | 1 | |||
| 4 | *4-14-1 | *WALL HUNG AHU | MITSUBISHI | SIPERNET RM MEZZ NORTH | 1.5 ton | 1 | ||||
| 4 | *4-15-1 | *AHU - Perf. Climate Changer | TRANE - CSIA008 | CENTER EAST PAVILLION ATTIC SOUTH SIDE | 3.7KCFM / 102 MBH CW Coil | 1 | ||||
| 4 | *4-15-2 | *Ceiling mounted FCU Uni-Trane | TRANE- FCEB0602C**D0A10AF3M00-D1YX0H | CEILING OF PERSONNEL RAMP FROM 3RD FLOOR INFILL | 7.8 MBH | 1 | ||||
| 4 | 4-NGB-1 | NATURAL GAS BOILER | LOCHINVAR PBN 2001 | PENTHOUSE | 2000 MBH (Input) | 1 | ||||
| 4 | 4-NGB-2 | NATURAL GAS BOILER | LOCHINVAR PBN 2001 | PENTHOUSE | 2000 MBH (Input) | 1 | ||||
| 4 | 4-NGB-3 | NATURAL GAS BOILER | LOCHINVAR PBN 2001 | PENTHOUSE | 2000 MBH (Input) | 1 | ||||
| 4 | 4-NGB-4 | NATURAL GAS BOILER | LOCHINVAR PBN 2001 | PENTHOUSE | 2000 MBH (Input) | 1 | ||||
| 4 | *FAN COIL UNIT 119.5 | YORK | 2ND FLOOR SOUTH WING EXTERIOR | 1 Ton | 1 | |||||
| 4 | *FAN COIL UNIT 120.5 | YORK | 2ND FLOOR SOUTH WING EXTERIOR | 1 Ton | 1 | |||||
| 4 | *FAN COIL U NIT 121.5 | YORK | 2ND FLOOR SOUTH WING EXTERIOR | 1 Ton | 1 | |||||
| 4 | *FAN COIL UNIT 122.5 | YORK | 2ND FLOOR SOUTH WING EXTERIOR | 1 Ton | 1 | |||||
| 4 | *FAN COIL UNIT 125.5 | YORK | 2ND FLOOR SOUTH WING EXTERIOR | 1 Ton | 1 | |||||
| 4 | *FAN COIL UNIT 127.5 | YORK | 2ND FLOOR SOUTH WING EXTERIOR | 1 Ton | 1 | |||||
| 4 | *FAN COIL UNIT 118.5 | YORK | 2ND FLOOR SOUTHEASE PAVILLION SOUTH WALL | 1 Ton | 1 | |||||
| 4 | *4-16 | *MINI SPLIT CONDENSER | MITSUBISHI- PUYA18NHA6- CONDENSERI | BLDG. 4 ROOF | 1.5 ton | 1 | ||||
| 4 | *4-16-1 | *MINI SPLIT EVAPORATOR | MITSUBISHI- PKA-A18HA- EVAPATOR | BLDG.4 ELEVATOR MACHINE ROOM | 1.5 ton | 1 | ||||
| 4 | *4-17 | *MINI SPLIT CONDENSER | MITSUBISHI-PUYA18NHA6-CONDENSER | BLDG.4 ROOF | 1.5 ton | 1 | ||||
| 4 | *4-17-1 | *MINI SPLIT EVAPORATOR | MITSUBISHI-PKA-A18HA- EVAPTOR | BLDG. 4 ELEVATOR MACHINE ROOM | 1.5 ton | 1 | ||||
| 4 | *4-18 | *MINI SPLIT CONDENSER | MITSUBISHI- PUY-A24NHA CONDENSER | BLDG. 4 ROOF | 2 ton | 1 | ||||
| 4 | *4-18-1 | *MINI SPLIT EVAPORATOR | MITSUBISHI- PKA-A24HA-EVAPATOR | BLDG.4 MEZZ. SOUTH VTC ROOM | 2 ton | 1 | ||||
| 4 | *MINI SPLIT CONDENSER | MITSUBISH I- PUY-A30 | Bldg 4 SE Exterior | 2.5 Ton | 1 | |||||
| 4 | *MINI SPLIT EVAPORATOR | MITSUBISHI- PKA-A30 | Bldg. 4 SE Freight Elevator Machine Room | 2.5 Ton | 1 | |||||
| 4 | *AHU-7 | *AHU-7 | TRANE CENTRIFUGAL AIR FOIL FAN (Used as Bathroom Exhaust Fan) | BLDG.4 PENTHOUSE | 15,800 CFM | 1 | ||||
| 29 | *29-1 | *120 TON CHILLER | TRANE | ROOF | AIR | 120 ton | 1 | |||
| 29 | *BARD WALL MOUNT-SELF CONTAINED | BARD W36HBDA10 | TRAILERS | 3 TON | 16 | |||||
| 29 | *29-1-1 | *AHU-1 | TRANE CCDB08 ANEC | 3.2 KCFM / 77 MBH Cooling / 65 MBH HW Coil | 1 | |||||
| 29 | *29-1-2 | *AHU-2 | TRANE CCDB08ANEC | 3.3 KCFM / 79 MBH Cooling / 66 MBH HW Coil | 1 | |||||
| 29 | *29-1-3 | *AHU-3 | TRANE CCDB08ANEC | 4.4 KCFM / 102 MBH Cooling / 90 MBH HW Coil | 1 | |||||
| 29 | *29-1-4 | *AHU-4 | TRANE CCDB08ANEC | 4.1 KCFM / 97 MBH Cooling / 88 MBH HW Coil | 1 | |||||
| 29 | *29-1-5 | *AHU-5 | TRANE CCDB08ANEC | 4.1 KCFM / 97 MBH Cooling / 87 MBH HW Coil | 1 | |||||
| 29 | *29-1-6 | *AHU-6 | TRANE MCCA017GA | 2ND FL NE | 8.7KCFM / 240 MBH Cooling / 137 MBH HW Coil | 1 | ||||
| 29 | *29-1-7 | *AH-4 | TRANE MCCA021G | 1ST FL SE WAREHOUSE | 9.4KCFM / 214 MBH Cooling/ 188 MBH HW Coil | 1 | ||||
| 29 | *29-1-8 | *AH-5 | TRANE MCCA003GA | 1ST FL NE WAREHOUSE | 1.4KCFM / 50 MBH Cooling/ 57 MBH HW Coil | 1 | ||||
| 29 | *29-1-9 | *AH-2 | TRANE MCCA010G | 1ST FL SW WAREHOUSE | 5.1KCFM / 118 MBH Cooling/ 162 MBH HW Coil | 1 | ||||
| 29 | *29-1-10 | *FCU 5 | MEZZ Room 105 HALLWAY | 1000 CFM | 1 | |||||
| 29 | *29-1-11 | *FCU 4 | MEZZ MEN'S LADIES ROOM | 1000 CFM | 1 | |||||
| 29 | *29-1-12 | *AH3 | TRANE MCCA006GAV6 | 1ST FL NE OFFICE CLOSET | 3.1 KCFM / 102 MBH Cooling / 76 MBH HW Coil | 1 | ||||
| 29 | *29-1-1P | *CW PUMP | MARATHON | 1ST FL MECHANICAL ROOM | 15 HP | 1 | ||||
| 29 | *29-1-2P | *CW PUMP | MARATHON | 1ST FL MECHANICAL ROOM | 15 HP | 1 | ||||
| 29 | 29-1-3P | HW PUMP | MARATHON | 1ST FL MECHANICAL ROOM | 7.5 HP | 1 | ||||
| 29 | 29-1-4P | HW PUMP | MARATHON | 1ST FL MECHANICAL ROOM | 7.5 HP | 1 | ||||
| 29 | FAN COIL UNIT | 1ST NORTH ENTRANCE | ~ 1 ton | 1 | ||||||
| 29 | FAN COIL UNIT | 1ST SW STAIR WELL | ~ 1 ton | 1 | ||||||
| 29 | FAN COIL UNIT | 1ST SW ENTRANCE | ~ 1 ton | 1 | ||||||
| 29 | FAN COIL UNIT | 2ND SW STAIRWELL | ~ 1 ton | 1 | ||||||
| 29 | FAN COIL UNIT | 2ND N CENTER STAIRWELL | ~ 1 ton | 1 | ||||||
| 29 | RADIATOR HEAT | Permiter of Building | ||||||||
| 29 | HOT WATER UNIT HEATERS | Modine HSB/HC-165 | Center Warehouse | 3240 CFM / 117.8 MBH | 2 | |||||
| 29 | HOT WATER UNIT HEATERS | Modine HSB/HC-47 | South Warehouse | 730 CFM / 27.8 MBH | 1 | |||||
| 29 | HOT WATER UNIT HEATERS | Modine HSB/HC-47 | Old Steam Room/Potable booster Pump Room | 730 CFM / 27.8 MBH | 1 | |||||
| 29 | HOT WATER UNIT HEATERS | Sterling HSB024 | BOILER ROOM | 450 CFM / 17.4 MBH | 1 | |||||
| 29 | HOT WATER UNIT HEATERS | Modine V/VN-42 | 1ST FLOOR SW CORNER | 950 CFM / 27.1 MBH | 1 | |||||
| 29 | *York Split AHU | York AHU | Equipment Storage Space Adjacent to ATM | 1.5 Ton | 1 | |||||
| 29 | *York Split Condenser | York Condenser YHJF18S41S1A | Equipment Storage Space Adjacent to ATM | 1.5 Ton | 1 | |||||
| 29 | *29-2 | *20 TON PKG UNIT RTU-1 | AAON, INC. | CHEM LAB NW SIDE LOW ROOF | 20 ton | 1 | ||||
| 29 | *29-3 | *7.5 TON PKG UNIT RTU-2 RETURN EXHAUST FUME HOOD SYSTEM | AAON, INC. | CHEM LAB NE SIDE LOW ROOF | 7.5 ton with hood system | 1 | ||||
| 29 | *Fume Hood Exhaust Fan | Greenheck TCBLE-2-18-50-X | CHEM LAB NE SIDE LOW ROOF | ~8000 CFM | 1 | |||||
| 29 | 29-NGB-1 | NATURAL GAS BOILER | LOCHINVAR PBN2001 | PENTHOUSE | 2000 MBH (Input) | 1 | ||||
| 29 | 29-NGB-2 | NATURAL GAS BOILER | LOCHINVAR PBN2001 | PENTHOUSE | 2000 MBH (Input) | 1 | ||||
| 29 | * | *EF-1 (Mezz Toilets) | Mezz Toilets (Ceiling Hung) | 1/4 HP 900 CFM | 1 | |||||
| 29 | * | *EF-2 (1st Fl. Toilets) | 1st Fl. Toilets (Roof) | 1/6 HP 425 CFM | 1 | |||||
| 29 | * | *EF-3 (Secuirty Toilets) | Security Toilets (Ceiling) | 48 watts / 75 CFM | 1 | |||||
| 77 | H | *77-H-4 | *7.5 TON SPLIT SYS | Trane TTA090H400AA | Bldg. 87/756 Courtyard (Split #4) | 7.5 ton | 1 | |||
| 77 | H | *77-H-4-1 | *AHU | Trane, TWE090E300AA | ROOF DDG 51 (Split #4) | 7.5 ton | 1 | |||
| 77 | H | *77-H-5 | *30 TON SPLIT SYS | CARRIER, 38APD03064A18020 | WEST SIDE GROUND (Split #2) | AIR | 30 ton | 1 | ||
| 77 | H | *77-H-5-1 | *AHU | CARRIER, 40RUAA3053A6-0A0A0 | ROOF DDG 51 (Split #2) | 30 ton | 1 | |||
| 77 | H | *77-H-6 | *12.5 TON SPLIT SYSTEM | TRANE TTA150h400AA | BLDG. 87/756 COURTYARD (Split #1) | AIR | 12.5 ton | 1 | ||
| 77 | H | *77-H-6-1 | *AHU | TRANE TWE150E300A | ROOF DDG 51(Split #1) | 12.5 ton | 1 | |||
| 77 | H | 77-H-7 | *10 TON SPLIT SYS | TRANE, TTA12044DDA | 756 Roof (Split #3) | 10 Ton | 1 | |||
| 77 | H | *77-H-7-1 | *10 TON AHU | TRANE, TWE12044BAA | ROOF DDG 51 (Split #3) | 10 Ton | 1 | |||
| 77 | H | *77-H-12 | *5 TON PKG UNIT | YORK, PCE4B6031B | TEST CELL # 5 (Air-Compressor Test Site) | AIR | 5 ton | 1 | ||
| 77 | H | *77-H-13 | *7.5 TON HT PMP | TRANE, TTA09043DAA00AR | PARKING LOT | AIR | 7.5 ton | 1 | ||
| 77 | H | *77-H-13-1 | * AHU | TRANE, TWE09043BAA00R | ROOF FIBER OPTICS | AIR | 7.5 ton | 1 | ||
| 77 | H | *77-H-16 | *40 TON PKG CHILL | YORK | E SIDE CENTER (Volumetric Flow Lab) | AIR | 40 ton | 1 | ||
| 77 | H | 77H-17 | HEAT/VENT | ILG Industries - PTB-24 | SE LOFT | 1 | ||||
| 77 | H | 77H-18 | HEAT/VENT | ILG Industries - PTB-24 | SW LOFT | AIR | 1 | |||
| 77 | H | 77H-19 | HEAT/VENT | ILG Industries - PTB-24 | NE LOFT | 1 | ||||
| 77 | H | 77H-20 | HEAT/VENT | ILG Industries - PTB-24 | NW LOFT | 1 | ||||
| 77 | H | *77H-21 | *10 TON Split System | TRANE, TTA120H400AA | Roof DDG 51 (Split #6) | 10 ton | 1 | |||
| * | *10 TON AHU | TRANE, TWE120E300AC | 756 ROOF (Split #6) | 10 ton | 1 | |||||
| 77 | H | *77-H-22 | *15 TON Split System | TRANE, TTA180H400AA | Roof DDG 51 (Split #5) | 15 ton | 1 | |||
| * | *10 TON AHU | TRANE, TWE180E300AA | 756 ROOF (Split #5) | 15 ton | 1 | |||||
| 77 | H | 77-H-23 | HEATING AHU | YORK XTI-039X066-DAJA 046A | MEZZ SE VOL FLOW | AIR | 1 | |||
| 77 | H | 77-H-24 | HEATING AHU | TRANE MCCA006GAG0AAA0001EBAA00A0B00A0BA0000000000 | MEZZ SE REST RMS | AIR | 1 | |||
| 77 | H | *77-H-25 | *5 TON SPLIT SYS | LIEBERT | W WALL OUTSIDE | 5 ton | 1 | |||
| 77 | H | *77-H-25-1 | *5 TON AHU | LIEBERT CHALLENGER 3000, Bu067A-AS | DDG-51 CONTROL HSE (1st fl North East of Control House) | 5 ton | 1 | |||
| 77 | H | *77H-26 | *15 TON SPLIT SYS H.P. | TRANE, TWA180B400BD | ROOF B#756 (Split #7) | AIR | 15 ton | 1 | ||
| 77 | H | *77H-26-1 | *15 TON AHU | TRANE TWE180B400CA | SDC ROOF (Split #7) | 15 ton | 1 | |||
| 77 | H | *77H-27 | *15 TON SPLIT SYS H.P. | TRANE TWA090A400BC | ROOF B#756 (Split #8) | AIR | 15 ton | 1 | ||
| 77 | H | *77H-27-1 | *15 TON AHU | TRANE TWE090A300AC | SDC ROOF (Split #8) | 15 ton | 1 | |||
| 77 | H | *77H-28 | *15 TON SPLIT SYS H.P. | TRANE, TWA180B400BD | ROOF B#756 (Split #11) | AIR | 15 ton | 1 | ||
| 77 | H | *77H-28-1 | *15 TON AHU | TRANE TWE180B400CA | SDC ROOF (Split # 11) | 15 ton | 1 | |||
| 77 | H | *77H-29 | *15 TON SPLIT SYS H.P. | TRANE, TWA180B400BD | ROOF B#756 (Split #10) | AIR | 15 ton | 1 | ||
| 77 | H | *77H-29-1 | *15 TON AHU | TRANE TWE180B400CA | SDC ROOF (Split #10) | 15 ton | 1 | |||
| 77 | H | *77H-30 | *10 TON SPLIT SYS | TRANE TWA120A400FB | ROOF B#756 (Split #9) | AIR | 10 ton | 1 | ||
| 77 | H | *77H-30-1 | *10 TON AHU | TRANE, TWE120A300CA | SDC ROOF (Split #9) | 10 ton | 1 | |||
| 77 | H | *77H-31 | *15 TON SPLIT SYS | TRANE TWA180B400BD | ROOF B#756 (Split #12) | AIR | 7.5 ton | 1 | ||
| 77 | H | *77H-31-1 | *15 TON AHU | TRANE, TWE180B400CA | SDC ROOF (Split #12) | 7.5 ton | 1 | |||
| 77 | H | *77H-32 | *3 TON MINI SPLIT | EMI SCC36DF0000AA0A | ROOF DDG 51 | 3 ton | 1 | |||
| 77 | H | *77H-32-1 | *WALL HUNG AHU | EMI, WHP36D020AA0 | DDG51, 2ND FL CONT RM | 3 ton | 1 | |||
| 77 | H | *77-H-33 | *3 TON MINI SPLIT | EMI, SCC36DF0000AA0A | ROOF DDG 51 | AIR | 3 ton | 1 | ||
| 77 | H | *77H-33-1 | *WALL HUNG AHU | EMI, WHP36D020AA0 | DDG51, 2ND FL CONT RM | 3 ton | 1 | |||
| 77 | H | *77H-34 | *5 TON SPLIT SYS | DECHAMPS PV-W1-WHO DX | E SIDE | AIR | 5 ton | 1 | ||
| 77 | H | *77H-34-1 | *AHU #4 | DECHAMPS PV-W1-WHO | E SIDE MEZZ ROOF | 5 ton | 1 | |||
| 77 | H | *77H-35 | *20TON SPLIT SYS | CARRIER, 38AUDB25A0A6-0A0C0 | E SIDE | AIR | 20 ton | 1 | ||
| 77 | H | *77H-35-1 | *AHU | CARRIER AHU #3 (6500 CFM) | ||||||
| 40RUAA25T3A6-0A0A0 | E SIDE MEZZ. ROOF | 20 ton | 1 | |||||||
| 77 | H | *77-35-2 | *AHU-3 RETURN FAN | E. SIDE MEZZ. | 3HP | 1 | ||||
| 77 | H | *77H-36 | *4 TON SPLIT SYS H.P. | TRANE TWA030-072 (TWA048D300A0) | WEST SIDE FIBER OPTICS | AIR | 4 ton | |||
| 77 | H | *77H-36-1 | *AHU | TRANE TWE048C4000 | ABOVE CEILING | 4 ton | 1 | |||
| 77 | H | 77H-H-1 | HUMIDIFIER | VAPORMIST DRISTEAM | FIBER OPTICS LAB | |||||
| 77 | H | 77H-H-2 | HUMIDIFIER | VAPORMIST DRISTEAM | FIBER OPTICS LAB | |||||
| 77 | H | 77H-B | BOILER 150 HP | HURST | EAST SIDE BOILER ROOM | 150 HP | 1 | |||
| 77 | H | Steam Boiler Condensate Return Pumps (1-3) | MEPCO - ERVD1030-1E | Col. D11 , A11, SE Corner, | Daul Pumps, 1 hp each | 3 | ||||
| 77 | H | * | *15-TON CONDENSER | TRANE TTA180E400AA | VM FLOW LAB EASE SIDE EXTERIOR | 15 ton | 1 | |||
| 77 | H | * | *AHU | TRANE TWE180E300AA | VM FLOW LAB EAST SIDE INTERIOR | 15 ton | 1 | |||
| 77 | H | *77H-37 | *MINI SPLIT SYSTEM CONDENSER | MITSUBISHI MXZ-4B36NA | AIR COMPRESSOR TEST SITE ROOF | 3 ton | 1 | |||
| 77 | H | *77H-37-1 | *MINI SPLIT SYSTEM EVAPORATOR | MITSUBISHI MSZGE09NA | ROOM 120 | 3/4 ton | 1 | |||
| 77 | H | *77H-37-2 | *MINI SPLIT STSTEM EVAPORATOR | MITSUBISHI MSZGE09NA | ROOM 122 | 3/4 ton | 1 | |||
| 77 | H | *77H-37-3 | *MINI SPLIT SYSTEM EVAPORATOR | MITSUBISHI MSZGE12NA | ROOM 122A | 1 ton | 1 | |||
| 77 | H | * | *MINI SPLIT CONDENSER | Mitsubishi MXZ2B20NA | East of Ladies Room | 1.5 ton | 1 | |||
| 77 | H | * | *MINI SPLIT EVAPORATOR | MITSUBISHI MSZ-GE09NA-8 | East Side Ladies Room | 3/4 ton | 2 | |||
| 77 | H | * | *MINI SPLIT CONDENSER | SANYO CH2472 | East Side of Locker Room | 2 ton | 1 | |||
| 77 | H | * | *MINI SPLIT EVAPORATOR | SANYO KHS-2472 | East Locker Room | 2 ton | 1 | |||
| 77 | H | * | *MINI SPLIT CONDENSER | FRIEDRICH Mr18Y3D | West Side of Arc-Fault Lab | 1.5 ton | 1 | |||
| 77 | H | * | *MINI SPLIT EVAPORATOR | FRIEDRICH MW18Y3D | Arc Fault Controller Room | 1.5 ton | 1 | |||
| 77 | H | 77H-IR-1 THRU IR- 25 | INFRARED UNIT HEATER | SCHWANK JR75-Small | HIGHBAY | 25 | ||||
| 77 | H | 77H-IR-26 THRU IR-78 | INFRARED UNIT HEATER | SCHWANK 100-Large | HIGHBAY | 55 | ||||
| 77 | H | GUH-1 THRU 4 | GAS UNIT HEATER | MODINE HEATERS PV175AEM0163 | HIGHBAY | 4 | ||||
| 77 | H | GUH-5, 7, 8 | GAS UNIT HEATER | MODINE HEATERS PV300AEM0464 | HIGHBAY | 3 | ||||
| 77 | H | GUH-10 | GAS UNIT HEATER | MODINE HEATERS PV175AEM0163 | HIGHBAY (670) | 1 | ||||
| 77 | H | * | *Highbay Exhaust Fan (1-8) | Highbay Roof | ~30,000 CFM. | 8 | ||||
| 77 | H | * | *Highbay Exhaust Fan (1-4 - Runs with Modine HVU's) | Highbay Roof | ||||||
| 77 | H | * | *East Side Men's Room Exhaust Fan | 1/20 HP | East Side Men's Room | 1 | ||||
| 77 | H | * | *East Side Ladies Locker Room | Mitsubishi-Mr Slim | Model # MSZ-GE09NA-8 | 1 | ||||
| 77 | H | * | *East Side Ladies Bath Room | Mitsubishi-Mr Slim | Model # MSZ-GE09NA-8 | 1 | ||||
| 77 | H | * | *West Side, South Control House 1st. Fl Restroom Exhaust Fan | West Side South Control House | 1 | |||||
| 77 | H | * | *West Side, South Control House 2nd. Fl Restroom Exhaust Fan | West Side South Control House | 1 | |||||
| 77 | H | * | *West Side, North DDG Control House, 2nd Fl. Restroom Exhaust Fan | West Side North Control House | 1 | |||||
| 77 | H | * | White Box Mini-Split Evap | Sanyo KS2472 | White Box East Central | 1 | ||||
| 77 | H | * | White Box Mini-Split Condenser | Sanyo C2472 | Roof of White Box East Central | 1 | ||||
| 77 | H | * | White Box Mini-Split Evap | Sanyo KS2472 | White Box East Central | 1 | ||||
| 77 | H | * | White Box Mini-Split Condenser | Sanyo C2472 | Roof of White Box East Central | 1 | ||||
| 77 | L | 77L-1 | 300 TON CHILLER | YORK | 1ST FL MER | 300 ton | 1 | |||
| 77 | L | *77l-1-1 | AC-1 | SUPPLY & RETURN FANS | ABOVE MECH RM | 1,506,597 BTU/HR | 1 | |||
| 77 | L | * | *AC-1, R-4 | CHAMPION 400 | ABOVE MECH RM | 5 HP | 1 | |||
| 77 | L | * | *AC-1, R-5 | CHAMPION 300 | ABOVE MECH RM | 1-1/2 HP | 1 | |||
| 77 | L | * | *AC-1, R-6 | CHAMPION 402 | ABOVE Center Restrooms | 5 HP | 1 | |||
| 77 | L | * | *AC-1, S-1 | CHAMPION 300 | ABOVE MECH RM | 5 HP, 8,670 CFM | 1 | |||
| 77 | L | * | *AC-1, S-2 | CHAMPION 490 | ABOVE MECH RM | 20 HP, 30,475 CFM | 1 | |||
| 77 | L | * | *AC-1, S-3 | CHAMPION 270 | ABOVE MECH RM | 5 HP, 7,460 CFM | 1 | |||
| 77 | L | * | *AC-1 Exhaust Fans 1-4 | ABOVE MECH RM | 3/4 HP, 5,000 CFM | 4 | ||||
| 77 | L | * | *Machine Room Exhaust Fan | 24" DIA, 2SPD, PROP. EXHAUST FAN | ABOVE MECH RM | 3 HP, 9,350CFM | 1 | |||
| 77 | L | *77L-1-2 | *AHU #2 (AC2) | TRANE | Above 500 Area | 5HP, 5.6 KCFM, 225 MBH Cooling | 1 | |||
| 77 | L | *77L-1-3 | *AHU #3 (AC3) | CARRIER | COL. B-43 CEILING | 15 HP, 13030 CFM, 568 MBH Cooling | 1 | |||
| 77 | L | *77L-1-4 | *AHU#4 (AC4) | CARRIER | COL B-43 CEILING | 7.5 HP, 7500 CFM, 291 MBH Cooling | 1 | |||
| 77 | L | *77L-1-6 | *AHU #6 (AC5) | CARRIER | SW COR CEILING | 3 HP, 3200 CFM, 180 MBH Cooiling | 1 | |||
| 77 | L | 77L-1-7 | *AC-7 | Carrier- SN: 1807U12662 | Column G-46 (South of chiller room in overhead) | 10 HP, 9200 CFM, 375 MBH | 1 | |||
| 77 | L | 77L-1-8 | TOWER | BAC S3E-8518-05M | ROOF | 300 Ton | 1 | |||
| 77 | L | *77L-1-9 | *AHU #8 (AC8) | CARRIER | NE COR ABOVE OFF. ON PLATFRM | 10 HP, 7220 CFM, 290 MBH | 1 | |||
| 77 | L | *77L-1-10 | *AHU #9 (AC9) | LIEBERT | SW MOUNT TEST LAB (Col. F35) | 2HP, 4650 CFM, 115 MBH | 1 | |||
| 77 | L | *77L-7 | *20 TON PKG UNIT | YORK | SE CORNER ROOF | AIR | 20 ton | 1 | ||
| 77 | L | *77L-1-1A | *AIR COMP & DRYER | DEVAIR RE-NOMDMT-20 | MECH RM | AIR | 1 | |||
| 77 | L | 77L-1-1P | CIRC PMP | TACO - TA1224B2K1A6C0 | MECH RM | AIR | 25 HP 900 GPM | 1 | ||
| 77 | L | 77L-1-2P | CIRC PMP | TACO | MECH RM | 50 HP 750 GPM | 1 | |||
| 77 | L | 77L-1-3P | CIRC PMP | TACO | MECH RM | 50 HP 750 GPM | 1 | |||
| 77 | L | 77L-B-1 | BOILER 150 HP | HURST | SW BOILER ROOM | 150 HP | 1 | |||
| 77 | L | 77L-B-2 | BOILER 150 HP | HURST | SW BOILER ROOM | 150 HP | 1 | |||
| 77 | L | 300-TON CHILLER | MCQUAY | NE EXTERIOR SIDE OF BLDG. | 300 ton | 1 | ||||
| 77 | L | CHILLER PUMP #1 | BALDOR | NE MECHANICAL ROOM | 30 HP | 1 | ||||
| 77 | L | CHILLER PUMP #2 | BALDOR | NE MECHANICAL ROOM | 30 HP | 1 | ||||
| 77 | L | * | *9-TON PACKAGE UNIT | AAON - RN-009-8-0-EB0913A | NORTH CTR. OF ROOF SERVING MELVILLE SPACE | 9 ton | 1 | |||
| 77 | L | * | *Warnock St. Men's/Women's A Exhaust Fan System | Behind restroom in pipe-chase area. | 1 | |||||
| 77 | L | * | *Mellville Women's Room B Exhaust Fan | Above restroom by Mellville (in ceiling) | 1/4 HP | 1 | ||||
| 77 | L | * | *Mellville Men's Room B Exhaust Fan | Above ceiling in restroom by Mellville. | 1/4 HP | 1 | ||||
| 77 | L | * | *2nd Fl Men's Room C Exhaust Fan | In ceilings of Men's room in center of bldg. | 1/4 HP | 1 | ||||
| 77 | L | * | *Center Hallway Handicap Restroom Exhaust Fan | Loren Cook | Above 1st ceiling near handicap. | 1/4 HP | 1 | |||
| 77 | L | * | *Center substation Exhaust Fan | Loren Cook - 195 CPV | Above substation ceiling. | 1/2 HP | 1 | |||
| 77 | L | * | *Men's/Women's Restroom Exhaust Fan D Near 77H/77L Access Door | Above ceiling in Mens room | 1/4 HP | 1 | ||||
| 77 | L | * | *Pedal Lab Through the Wall Exhaust Fans (1 - 4) | ????? | Pedal Lab East Wall High Bay Area | 4 | ||||
| 77 | L | Pedal Lab Steam Unit Heaters (1-6) | Modine HS763S01 | Pedal Lab Highbay Area | 1/12 HP, 76,000 BTU | 6 | ||||
| 77 | L | Steam Unit Heater outside of Boiler Room | Modine HS33S01 | Outside of Boiler Room | 1/25 HP, 33,000 BTU | 1 | ||||
| 77 | L | Boiler Condensate Return Pumps (1-5) | MEPCO - ERVD1030-1E | Chiller Room, Warnock Street Restooms, 1600, Pedal lab, NE Mechancal | Dual pumps, 1 HP Each | 5 | ||||
| 771 | Steam Unit Heaters | Modine HS33S01 | 771 | 33,000 BTU | 2 | |||||
| 771 | Steam Unit Heaters | Modine HS63S01 | 771 | 63,000 BTU | 2 | |||||
| 771 | Steam Unit Heaters | MODINE HS24S01 | 771 | 24,000 BTU | 1 | |||||
| 771 | Steam Unit Heaters | Modine HS108S01 | 771 | 108,000 BTU | 2 | |||||
| 771 | Boiler Condensate Return Pumps | MEPCO - ERVD1030-1E | 771 | Dual pumps, 1 HP Each | 1 | |||||
| 77 | L | *77L-2 | *MINI SPLIT - CONDENSER | FUJITSU - AOU36CLX1 | 771 ROOF | 3 ton | 1 | |||
| 77 | L | *77L-2-1 | *MINI SPLIT EVAPORATOR | FUJITSU EVAPORATOR | NORTHEAST COMP. ROOM | 3 ton | 1 | |||
| 77 | L | *77L-3 | *MINI SPLIT - CONDENSER | FUJITSU - AOU36CLX1 | 771 ROOF | 3 ton | 1 | |||
| 77 | L | *77L-3-1 | *MINI SPLIT - EVAPORATOR | FUJITSU EVAPORATOR | NORTHEAST COMP. ROOM | 3 ton | 1 | |||
| 77 | L | *77L-4 | *MINI SPLIT CONDENSER | MITS. PUY-A24NHA6 | 771 ROOF | 2 ton | 1 | |||
| 77 | L | *77L-4-1 | *MINI SPLIT EVAPORATOR | MITS.PKA-A24HA EVAPORATOR | ROOM 703 | 2 ton | 1 | |||
| 77 | L | *77L-5 | *MINI SPLIT CONDENSER | MKITS. MXZ-4C36NAHZ | 771 ROOF | 3 ton | 1 | |||
| 77 | L | *77L5-1 | *MINI SPLIT EVAPORATOR | MITS. PLA-A18BA7 | ROOM 704 AND 705 | 1.5 ton | 1 | |||
| 77 | L | *77L-5-2 | *MINI SPLIT EVAPORATOR | MITS. PLA-A18BA7 | ROOM 704 AND 705 | 1.5 ton | 1 | |||
| 77 | L | *77L-6 | *10-TON SPLIT SYSTEM CONDENSER | TRANE TWL120 | WEST SIDE MACHINERY CTL. TEST SITE | 10 ton | 1 | |||
| 77 | L | *77L-6-1 | *10-TON SPLIT SYSTEM EVAPORATOR | TRANE TTA120 | WEST SIDE MACHINERY CTL. TEST SITE | 10 ton | 1 | |||
| 77 | L | *77L-7 | *10-TON SPLIT SYSTEM CONDENSER | TRANE TWL120 | WEST SIDE MACHINERY CTL. TEST SITE | 10 ton | 1 | |||
| 77 | L | *77L-7-1 | *10-TON SPLIT SYSTEM EVAPORATOR | TRANE TTA120 | WEST SIDE MACHINERY CTL. TEST SITE | 10 ton | 1 | |||
| 77 | L | *77L-8 | *MINI SPLIT CONDENSER | SANYO 24,000 BTU CONDENSER | 77L ROOF | 2 ton | 1 | |||
| 77 | L | *77-8-1 | *MINI SPLIT EVAPORATOR | SANYO KS2472 EVAPORATOR HEAD | CENTER COMPUTER ROOM | 2 ton | 1 | |||
| 77 | L | * | *10-TON SPLIT SYSTEM CONDENSER | TRANE TWL120 | WEST SIDE MACHINERY CTL. TEST SITE | 10 ton | 1 | |||
| 77 | L | * | *10-TON SPLIT SYSTEM EVAPORATOR | TRANE TTA120 | WEST SIDE MACHINERY CTL. TEST SITE | 10 ton | 1 | |||
| 77 | L | * | *10-TON SPLIT SYSTEM CONDENSER | TRANE TWL120 | WEST SIDE MACHINERY CTL. TEST SITE | 10 ton | 1 | |||
| 77 | L | * | *10-TON SPLIT SYSTEM EVAPORATOR | TRANE TTA120 | WEST SIDE MACHINERY CTL. TEST SITE | 10 ton | 1 | |||
| 77 | L | * | *10-TON SPLIT SYSTEM CONDENSER | TRANE TWL120 | WEST SIDE MACHINERY CTL. TEST SITE | 10 ton | 1 | |||
| 77 | L | * | *10-TON SPLIT SYSTEM EVAPORATOR | TRANE TTA120 | WEST SIDE MACHINERY CTL. TEST SITE | 10 ton | 1 | |||
| 77 | L | * | *ERV-1 | Greenheck Minivent-750-VG | WEST SIDE MACHINERY CTL. TEST SITE | 3/4 HP 350 CFM | 1 | |||
| 77 | L | 77L-1307-1* | Mini-Split Evap | Mitsubishi MSZ 15 | RM. 1307 | 1.25 Tons | 1 | |||
| 77 | L | 77L-1307-1-1* | Mini-Split Condenser | Mitsubishi MXZ-3C30NA2 | Roof | 3.5 Tons | 1 | |||
| 77 | L | 77L-1306-1* | Mini-Split Evap | Mitsubishi MSZ 15 | Rm. 1306 | 1.25 Tons | 1 | |||
| 87 | *87-1 THRU *87-33 | *1 TON HEAT PUMP (PTAC) | AMANA | E. & CNTR BAYS | 1 ton | 33 | ||||
| 87 | *87-45 | *VENTILATION UNIT | YORK 17,320 CFM | COL C-13 MEZZ CNTR BAY | 17,320 CFM | 1 | ||||
| 87 | 87-47 | 50 TON CHILLER | YORK ZB4K1-B46/50S | M.R. COL C-2 | 50 ton | 1 | ||||
| 87 | *87-47-1 | *25 TON AHU | YORK A/C -2 W/S & R FANS | AMR UPPER | 25 ton | 1 | ||||
| 87 | *87-47-2 | *25 TON AHU | YORK A/C -3 W/S & R FANS | AMR LOWER | TOWER/NOC | 25 ton | 1 | |||
| 87 | *87-47-3 | *5-TON AHU | TRANE | INSIDE P-107 AREA | 5 ton | 1 | ||||
| 87 | *87-47-4 | *5-TON AHU | TRANE | INSIDE P-107 AREA | 5 ton | 1 | ||||
| 87 | *87-47-5 | *5-TON AHU | TRANE | INSIDE P-107 AREA | 5 ton | 1 | ||||
| 87 | *87-47-6 | *5-TON AHU | TRANE | INSIDE P-107 AREA | 5 ton | 1 | ||||
| 87 | *87-46-7 | *5-TON AHU | TRANE | INSIDE P-107 AREA | 5 ton | 1 | ||||
| 87 | *87-46-8 | *5-TON AHU | TRANE | INSIDE P-107 AREA | 5 ton | 1 | ||||
| 87 | *87-46-9 | *5-TON AHU | TRANE | INSIDE P-107 AREA | 5 ton | 1 | ||||
| 87 | *87-47-10 | *5-TON AHU | TRANE | INSIDE P-107 AREA | 5 ton | 1 | ||||
| 87 | *87-47-11 | *5-TON AHU | TRANE | INSIDE P-107 AREA | 5 ton | 1 | ||||
| 87 | 87-47-1P | 7.5 HP CW PUMP | U.S. ELECTRIC | MECH ROOM COL. C-2 | 7.5 hp | 1 | ||||
| 87 | 87-CU-2 | CONDENSER UNIT (DRY COOLER) | HEATCRAFT - BFH060 | North Exterior GROUND LEVEL | 50 Tons | 1 | ||||
| 87 | 87-PP-1 | PUMP PACKAGE (DRY COOLER) | DRAKE - P57.5DA-T4 | GROUND LEVEL | dual pumps, 7.5 HP Each | 1 | ||||
| 87 | * | *P-107 CHILLER | TRANE - RTAA 0704YT01A300JGRANTPC | SOUTH EXTERIOR OF P107 | 70 Tons | 1 | ||||
| 87 | * | *P-107 AHU | TRANE - MCCB010 | ROOF SOUTH SIDE OFFICE AREA OF P107 | 7.5 HP / 5455 CFM / 255 MBH Cooling / 205 MBH Heating | 1 | ||||
| 87 | P-107 BOILER | LOCHIAVAR-EBN200 | P107 Roof | 168,000 BTU/HR Output | 1 | |||||
| 87 | P-107 BOILER | LOCHIAVAR-EBN200 | P107 Roof | 168,000 BTU/HR Output | 1 | |||||
| 87 | P-107 P-B-1 PUMP | Bell & Gossett Series 90 1-1/2a | P107 Roof | 1HP 31 GPM | 1 | |||||
| 87 | P-107 P-B-1 PUMP | Bell & Gossett Series 90 1-1/2a | P107 Roof | 1 HP 31 GPM | 1 | |||||
| 87 | * | *P-107 Pump-CH-1 | Bell & Gossett Series 80 | P107 Roof | 5 HP 134 GPM | 1 | ||||
| 87 | * | *P-107 Pump-CH-1 | Bell & Gossett Series 80 | P107 Roof | 5 HP 134 GPM | 1 | ||||
| 87 | * | * Cave 5-TON PACKAGE UNIT | CARRIER 50TC-A07A2A6A0A0G0 | UNIT ROOF OF CAVE SITE | 5 ton | 1 | ||||
| 87 | * | *Cave MiniSplit | MITSUBISHI Evap | CAVE SITE, SW CORNER RM | 2.5 ton | 1 | ||||
| 87 | * | *Cave MiniSplit | MITSUBISHI Condenser PUY-A30NHA | UNIT ROOF OF CAVE SITE | 2.5 ton | 1 | ||||
| 87 | * | *Elevator MR MiniSplit Evap | EMI Evap | Elevator machine room | 1 Ton | 1 | ||||
| 87 | * | *Elevator MR EMI MiniSplit Condenser | EMI Condenser | North of P-107 in highbay | 1 Ton | 1 | ||||
| 87 | * | *Elevator Machine Room Exhaust Fan | Greenheck CW-070-G | Elevator machine room | 1/60 HP / 100 CFM | 1 | ||||
| 87 | * | *Fan Coil Unit | Trane BCHD054 | P-107 DAS Room | 4.5 Tons | 1 | ||||
| 87 | 87-DAS-1* | DAS Mini Split Evap | Mitsubishi - PKA36 | P-107 DAS Room | 3 Tons | 1 | ||||
| 87 | 87-DAS-1-1* | DAS Mini Split Condenser | Mitsubishi - PUYA36NKA7 | P-107 DAS Room | 3 Tons | 1 | ||||
| 87 | 87-1210-1* | Rm 1210 Mini Split Evap | Trane/Mitsubishi TPLA0A0301EA70A | Rm 1210. | 2.5 Tons | 1 | ||||
| 87 | 87-1210-1-1* | Rm 1210 Mini Split Condenser | Trane/Mitsubishi TRUYA0301HA70NA | Rm 1212 Roof | 2.5 Tons | 1 | ||||
| 87 | 87-1210-2* | Rm 1210 Mini Split Evap | Trane/Mitsubishi TPLA0A0301EA70A | Rm 1210. | 2.5 Tons | 1 | ||||
| 87 | 87-1210-2-1* | Rm 1210 Mini Split Condenser | Trane/Mitsubishi TRUYA0301HA70NA | Rm 1212 Roof | 2.5 Tons | 1 | ||||
| 87 | *87-SS1 | *MINI SPLIT SYSTEM CONDENSER | PUZA42NKA7 | WEAPONS ELEVATOR CONTROL HOUSE ROOF | 3.5 ton | 1 | ||||
| 87 | *87-SS1-1 | *MINI SPLIT SYSTEM EVAPORATOR | PCA-42 | WEAPONS ELEVATOR CONTROL HOUSE | 3.5 ton | 1 | ||||
| 87 | *87-SS2 | *MINI SPLIT SYSTEM CONDENSER | PUZ-A18NKA7 | WEAPONS ELEVATOR CONTROL HOUSE ROOF | 1.5 ton | 1 | ||||
| 87 | *87-SS2-1 | *MINI SPLIT SYSTEM EVAPORATOR | PLA-A18 | WEAPONS ELEVATOR CONTROL HOUSE | 1.5 ton | 1 | ||||
| 87 | * | *MINI SPLIT CONDESNER | MITSUBISHI PUZ-A42NKA7 | Cake Box SW End (exterior of box) | 42,000 BTU | 1 | ||||
| 87 | * | *MINI SPLIT EVAPORATOR | MITSUBISHI | Inside Cake Box SW End. | 42,000 BTU | 1 | ||||
| 87 | * | * MINI SPLIT EVAPORATOR | Mitsubishi/Trane - TPLA0A0301EA70A | Room 1211 | 2.5 Tons | 2 | ||||
| 87 | * | *MINI SPLIT CONDESNER | Mitsubishi/Trane - TRUYA301HA70NA | Room 1212 Roof | 2.5 Tons | 2 | ||||
| 87 | * | *Highbay Exhaust Fan (1-9) | Highbay | ~30,000 CFM | 9 | |||||
| 87 | * | *North Restroom Exhaust Fan | North Restroom | 1 | ||||||
| 87 | * | *South Restroom Exhaust Fan | South Restroom | 1 | ||||||
| 87 | INFRARED UNIT HEATER | Re-Verber-Ray DR80 | HIGHBAY | 80,000 BTU | 68 | |||||
| 87 | INFRARED UNIT HEATER | Re-Verber-Ray DR60 | HIGHBAY | 60,000 BTU | 31 | |||||
| 87 | INFRARED UNIT HEATER | Re-Verber-Ray DR30 | HIGHBAY | 30,000 BTU | 3 | |||||
| 520 | 520-GUH-1 thru 2 | GAS UNIT HEATER | MODINE HDS-45 | HIGHBAY | 45,000 Input, 36,900 BTU ouput | 2 | ||||
| 520 | 520-GUH-3-14 | GAS UNIT HEATER | MODINE PTS-150 | HIGHBAY | 150,000 Input, 120,000 BTU Output | 12 | ||||
| 520 | 520-ARU-1 | AIR ROTATION UNIT | POWRMATIC TE-11 | EAST SIDE | 500,000 BTU Input, 400,000 BTU Output | 1 | ||||
| 520 | 520-ARU-2 | AIR ROTATION UNIT | POWRMATIC TE-11 | WEST SIDE | 500,000 BTU Input, 400,000 BTU Output | 1 | ||||
| 531 | * | *DUCTLESS SPLIT SYSTEM (MR. SLIM) | MITSUBISHI Evap - PLA-A-42 | MECHANICAL SPACE/BEHIND 531 | 3.5 Ton | 1 | ||||
| 531 | * | *DUCTLESS SPLIT SYSTEM (MR. SLIM) | MITSUBISHI Condenser - PUY-A42NHA3 | West Exterior 531 | 3.5 Ton | 1 | ||||
| 531 | * | *3 TON SPLIT SYSTEM | TRANE Condenser- 4TWR5036G1000 | West Exterior 531 | 3 ton | 1 | ||||
| 531 | * | *3 TON SPLIT SYSTEM (AHU) | Trane AHU - 4TEE3F36 | Attic | 3 ton | 1 | ||||
| 531 | * | *2 TON SPLIT SYSTEM | TRANE Condenser- 4TWR5024G1000 | West Exterior 531 | 2 ton | 1 | ||||
| 531 | * | *2 TON SPLIT SYSTEM (AHU) | Trane AHU - 4TEE3F24 | Attic | 2 ton | 1 | ||||
| 531 | * | *2 TON SPLIT SYSTEM | TRANE Condenser - 4TWR5024G1000 | West Exterior 531 | 2 ton | 1 | ||||
| 531 | * | *2 TON SPLIT SYSTEM (AHU) | Trane AHU - 4TEE3F24 | Attic | 2 ton | 1 | ||||
| 531 | * | *1.5 TON SPLIT SYSTEM | TRANE Condenser - 4TWRS018G1000 | West Exterior 531 | 1.5 ton | 1 | ||||
| 531 | * | *1.5 TON SPLIT SYSTEM (AHU) | Trane AHU - 4TEE3F18 | Attic | 1.5 ton | 1 | ||||
| 531 | * | *ERV System - 1 | Greenheck Minivent 750 | Attic | 1/3 HP / 500 CFM | 1 | ||||
| 531 | * | *Restroom Exhaust Fan | Greenheck SP-A410 | Women's Room | 250 CFM | 1 | ||||
| 531 | * | *Janitor's Exhaust Fan | Greenheck SP-CP-90 | Ceiling Cabinet | 50 CFM | 1 | ||||
| 531 | * | *Utility Rm Exhaust Fan | Greenheck SP-A710 | Ceiling Cabinet | 260 CFM | 1 | ||||
| 542 | IR Units | Reverberray DR-75 | Column Lines | 75,000 BTU | 55 | |||||
| 542 | GAS FIRED FURNACE HEATER-XR9C | TRANE - TUX1000C960D3 | SOUTHWEST CORNER | 100,000 BTU | 1 | |||||
| 542 | GAS FIRED FURNACE HEATER-XR9C | TRANE - TUX1000C960D3 | SOUTHWEST CORNER | 100,000 BTU | 1 | |||||
| 542 | GAS FIRED FURNACE HEATER-XR9C | TRANE - TUX1000C960D3 | SOUTHWEST CORNER | 100,000 BTU | 1 | |||||
| 542 | GAS FIRED FURNACE HEATER-XR9C | TRANE - TUX1000C960D3 | SOUTHWEST CORNER | 100,000 BTU | 1 | |||||
| 542 | * | *Restroom Exhaust Fans | South East Sde | 2 | ||||||
| 633 | *633-12 | *40 TON CHILLER | Carrier - 30RAND40---611CX | NE ROOF | AIR | 40 ton | 1 | |||
| 633 | *633-12-1 | *AHU #1 | LIEBERT - BF102C-AAEI9761 | TOACC-1ST FLOOR | GLYCOL | 5 Ton | 1 | |||
| 633 | *633-12-2 | *AHU #2 | LIEBERT - BF102C-AAEI9761 | TOACC-1ST FLOOR | GLYCOL | 5 Ton | 1 | |||
| 633 | *633-12-3 | *AHU #3 | LIEBERT - BF102C-AAEI9761 | TOACC-1ST FLOOR | GLYCOL | 5 Ton | 1 | |||
| 633 | *633-12-4 | *AHU #4 | LIEBERT - BF102C-AAEI9761 | TOACC-1ST FLOOR | GLYCOL | 5 Ton | 1 | |||
| 633 | *633-12-5 | *AHU #5 | LIEBERT - BF102C-AAEI9761 | TOACC-1ST FLOOR | GLYCOL | 5 Ton | 1 | |||
| 633 | *633-12-6 | *AHU #6 | EDPAC CWS-D5-00 | TOACC-1ST Conf. room | 1 | |||||
| 633 | 633-12-1P | HW CIRC PUMP | ARMSTRONG H52-BF | TOACC MECH RM 1ST | 1 | |||||
| 633 | 633-12-2P | HW CIRC PUMP | ARMSTRONG H52-BF | TOACC MECH RM 1ST | 1 | |||||
| 633 | 633-12-3P | HW CIRC PUMP | ARMSTRONG H41 | TOACC MECH RM 1ST | 1 | |||||
| 633 | *633-12-4P | *CW CIRC PUMP | VALLEY PUMP GROUP | TOACC MECH RM 1ST | 5 HP / 63 GPM | 1 | ||||
| 633 | *633-12-5P | *CW CIRC PUMP | VALLEY PUMP GROUP | TOACC MECH RM 1ST | 5 HP / 63 GPM | 1 | ||||
| 633 | *633-13 | *2 TON SPLIT SYS | YORK YCJD24S1S1A | NORTH ALLEY | 2 ton | 1 | ||||
| 633 | *633-13-1 | *AHU | YORK | TAPE STORAGE RM (vault) | 2 ton | 1 | ||||
| 633 | 633-MAU-1 | MAKE-UP AIR UNIT | REZNOR | ROOF, EAST SIDE | 12,000 cfm, 640 MBH output. | 1 | ||||
| 633 | 633-NGB-1 | NATURAL GAS BOILER SYSTEM | PRESTIGE - PT-399 | BOILER SHOP | Input 399 MBH, Output 379 MBH | 1 | ||||
| 633 | * | *5-TON SPLIT SYS | LIEBERT | P-104 Roof | 5 ton | 1 | ||||
| 633 | * | *5-TON AHU | LIEBERT | P-104 Control Room | 5 ton | 1 | ||||
| 633 | * | *P-104 Control Rm Exhaust Fan | Exhaust Fan | P-104 Control Room | 1/4 HP 120 CFM | 1 | ||||
| 633 | * | *59.2-TON CHILLER | CARRIER 30RAP060 | EAST ROOF SOUTH END | AIR | 59.2 ton | 1 | |||
| 633 | * | *59.2-TON CHILLER | CARRIER 30RAP060 | EAST ROOF SOUTH END | AIR | 59.2 ton | 1 | |||
| 633 | * | *AHU-1 RETURN FAN | PENNBARRY SX335BC | PENTHOUSE | 13,085 CFM | 1 | ||||
| 633 | * | * AHU -1 | CARRIER 30-39MN | PENTHOUSE SOUTH | 15,320 CFM | 1 | ||||
| 633 | HW BOILER | RBI CB-750 | PENTHOUSE NORTH | 750 MBH | 1 | |||||
| 633 | HW BOILER | RBI CB-750 | PENTHOUSE NORTH | 750 MBH | 1 | |||||
| 633 | 55 GPM HOT WATER PUMP | PATTERSON E1.5B9A0 | PENTHOUSE | 3 HP 55 GPM | 1 | |||||
| 633 | 55 GPM HOT WATER PUMP | PATTERSON E1.5B9A1 | PENTHOUSE | 3 HP 55 GPM | 1 | |||||
| 633 | * | *120 GPM CHILLED WATER PUMP | PATTERSON E1.5B9A1 | PENTHOUSE | 5 HP 120 GPM | 1 | ||||
| 633 | * | *120 GPM CHILLED WATER PUMP | PATTERSON E1.5B9A2 | PENTHOUSE | 5 HP 120 GPM | 1 | ||||
| 633 | *300 CFM FAN COIL UNIT | CARRIER CSS-42CE | 1ST FLOOR LOBBY CEILING | 300 CFM | 1 | |||||
| 633 | UNIT HEATERS | RITTLIING RH018H01SAC | 4 EACH IN PENTHOUSE/1 EACH IN FIRE PUMP ROOM | 1/30 HP / 310 CFM / 18,000 BTU Heating | 4 | |||||
| 633 | 275 CFM CABINET UNIT HEATERS | RITTLING RFRW | 1ST FLOOR VESTIBULE | 275 CFM | 1 | |||||
| 633 | * | *Mini-Split | Mits Condenser - MUZ-GE09NA | Penthouse Room | 1 Ton | 1 | ||||
| 633 | * | *Mini-Split | MITSUBISHI MSZ6E09NA | 3RD FLOOR, IT ROOM | 1 ton | 1 | ||||
| 633 | * | AIR ROTATION UNIT | POWRMATIC - TE-41 | SOUTHEAST CORNER | 2,187,000 BTU | 1 | ||||
| 633 | * | *DAS Liebert Mini-Mates | LIEBERT Condenser - PFH037A-AL7 | Roof | 3 ton | 2 | ||||
| 633 | * | *DAS Liebert Mini-Mates | LIEBERTEvap - MMD36E7A0SDD | 2ND FLOOR, DAS ROOM | 3 Tons | 2 | ||||
| 633 | * | *Telecom Room Mini-Split | Mits - Evap - MSY015NA | 2ND FLOOR, TELECOM ROOM | 15,000 BTU | 1 | ||||
| 633 | * | *Telecom Room Mini-Split | Mits - Condenser - MUYGE15NA | Penthouse Roof | 15,000 BTU | 1 | ||||
| 633 | * | *Mini-Split | Mits Evap - MSY-030NA | 2ND FLOOR, ELECTRICAL ROOM | 2.5 Tons | 1 | ||||
| 633 | * | *Mini-Split | Mits Condenser - MUYD30NA-1 | Penthouse Roof | 2.5 Tons | 1 | ||||
| 633 | * | * AHU - 2 | TRANE | PENTHOUSE | 20 HP, 89000 CFM, 380 MBH Cooling / | |||||
| 102 MBH Heating | 1 | |||||||||
| 633 | * | *FAN COIL UNIT (1.5 TONS) | TRANE | 1ST FLOOR LOBBY CEILING | 1.5 Tons | 1 | ||||
| 633 | * | *FAN COIL UNIT (3 TONS) | TRANE | 1ST FLOOR RESTROOM | 3 Tons | 1 | ||||
| 633 | * | *FAN COIL UNIT (4.5 TONS) | TRANE | 2ND FLOOR CONFERENCE ROOM | 4.5 Tons | 1 | ||||
| 633 | * | *EXHAUST FAN (1330 CFM) | AMERICAN COOLAIR | PENTHOUSE ROOF | 1330 CFM | 1 | ||||
| 633 | * | *EXHAUST FAN (800 CFM) | AMERICAN COOLAIR | 1ST FLOOR NEXT TO FIRE PUMP ROOM | 800 CFM | 1 | ||||
| 633 | * | *Penthouse Exhaust Fan | Pennbarry BLL24 | Penthouse | 1/2 HP / 2750 CFM | 1 | ||||
| 633 | * | *Exhaust Fan | Pennbarry DX11B | Admin Roof Adjacent to Penthosue | 1/4 HP / ~500-1800 CFM | 1 | ||||
| 633 | * | *Exhaust Fan | Pennbarry DX11B | Penthouse Roof | 1/4 HP / ~500-1800 CFM | 2 | ||||
| 633 | * | *WALL MOUNTED A/C | AIRPAK 150 | E- HOUSE | 12.5 TONS | 7 | ||||
| 633 | * | *AHU-1 PACKAGE UNIT | VPRX-350-50E-X-C-1DX | HIGHBAY EXTENSION | 7.5 HP / 17,000 CFM / 675 MBH Cooling | 1 | ||||
| 633 | * | *AHU-2 PACKAGE UNIT | VPR-210-10E-35I-C-1DX | HIGHBAY EXTENSION | 3 HP / 4600 CFM / 144 MBH Cooling / 290 MBH | 1 | ||||
| 633 | * | *EXHAUST FAN 20000 cfm (BELT) | GREENHECK GB-480 | HIGHBAY EXTENSION Roof | 5 HP / 20,000 CFM | 2 | ||||
| 633 | * | *EXHAUST FAN 1200 cfm (DIRECT) | GREENHECK SE1-12 | HIGHBAY EXTENSION South/North Wall | 1/4 HP 1200 CFM | 2 | ||||
| 633 | * | *HVU-1 YORK HVU 36K cfm MAKE UP WITH GAS FURNACE | XTO-102X120-HARA046A | P-104 | 40HP / 36,000 CFM / | 1 | ||||
| 633 | * | *EXHAUST FAN (approx. 36K cfm) | NA | P-104 | 25 HP / 36,000 CFM | 1 | ||||
| 633 | * | *TRANE SPLIT AHU | TWE120D300AB | UPS ENCLOSURE Roof | 10 Ton | 2 | ||||
| 633 | * | *TRANE SPLIT CONDENSER | TTA120---- | 666 Roof | 10 Ton | 2 | ||||
| 633 | * | *EXHAUST FAN | GREENCHECK GB-101-4-X | UPS ENCLOSURE Roof | 1/4 HP / ~500-1500 CFM | 1 | ||||
| 633 | *633-EF-1 THRU 6 | *EXHAUST Fans | JencoFan HREB-C 40,000 CFM | HIGHBAY | 40,000 CFM | 6 | ||||
| 633 | *633-EF- 7 | *EXHAUST Fan | GREENHECK 07-CSW-X-10-CW-UB-0-A3 | BATTERY STATION ENCLOSURE - HIGH BAY | 1 | |||||
| 633 | *633-EF-8 | *EXHAUST Fan | GREENHECK 12 SCW-X-10CW-UB-0-A5 | BATTERY STATION ENCKOSURE - HIGH BAY | 1 | |||||
| 633 | *633-14 | *MINI SPLIT CONDENSER | Daikin RX30NMVJU | BATTERY STATION ENCLOSURE Roof - HIGHBAY | 2.5 Ton | 1 | ||||
| 633 | *633-14-1 | *MINI SPLIT EVAPORATOR | Daikin FTX30NVJU | BATTERY STATION ENCLOSURE - HIGHBAY | 2.5 Ton | 1 | ||||
| 633 | *633-15 | *MINI SPLIT CONDENSER | Daikin RX30NMVJU | BATTERY STATION ENCLOSURE Roof - HIGHBAY | 2.5 Ton | 1 | ||||
| 633 | *633-15-1 | *MINI SPLIT EVAPORATOR | Daikin FTX30NVJU | BATTERY STATION ENCLOSURE - HIGHBAY | 2.5 Ton | 1 | ||||
| 633 | *633-PU-1 | *12.5 Ton York Package Unit with gas heat | York - ZF150N18R4A1BAA1A1 | Electric Shop | 12.5 ton | 1 | ||||
| 633 | *633-PU-2 | *4 Ton York Pachage Unit with gas heat | York - ZE048H12B4A1ABA1A1 | Tool Shed | 4 ton | 1 | ||||
| 633 | 633-IR-1 THRU IR- 11 | INFRARED UNIT HEATER | SCHWANK PRIMOSCHWANK-40 | HIGHBAY | 150,000 BTU Input, 101,600 BTU Output | 11 | ||||
| 633 | 633-IR-12 THRU IR-22 | INFRARED UNIT HEATER | SCHWANK PRIMOSCHWANK-15 | HIGHBAY | 56000 BTU Input, 35,400 BTU Output | 11 | ||||
| 633 | 633-GUH-1-12 | GAS UNIT HEATER | MODINE HDS-250 | HIGHBAY | 250,000 BTU input, 200, BTU Output | 12 | ||||
| 633 | * | *Stilt House Center Bay Bard | Bard - W23A1-B09EPAXXJ | HIGHBAY | 3 Tons | 1 | ||||
| 633 | * | *Stilt House Center Bay PTAC | Sanyo PTAC | HIGHBAY | ~1 ton | 3 | ||||
| 666 | 666-GUH-1 | GAS UNIT HEATER | MODINE PTS-200 | PUMP ROOM | 200,000 BTU Input, 160,000 BTU Output | 1 | ||||
| 666 | 666-GUH-2 | GAS UNIT HEATER | MODINE PTS-200 | PUMP ROOM | 200,000 BTU Input, 160,000 BTU Output | 1 | ||||
| 745 | 745-GUH-1 THRU GUH-5 | GAS UNIT HEATER | MODINE HDS-45 | BLDG. 745 | 45,000 Input, 36,900 BTU ouput | 5 | ||||
| 745 | 745-GUH-6 | GAS UNIT HEATER | MODINE HDS-100 | BLDG.745 | 100,000 Input, 80,000 BTU ouput | 1 | ||||
| 756 | *756-1 | *4 TON SPLIT SYS | COMMERCIAL COMFORT CAC048HCA | N.E. CORNER | 4 ton | 1 | ||||
| 756 | *756-1-1 | *AHU | TRANE TWE048C1140C0 | CAFETERIA ROOF | 4 ton | 1 | ||||
| 756 | 756 | Steam Heaters (1-6) | Durham Bush - 11-400-C | 756 | 1/8 HP | 6 | ||||
| 756 | 756 | Steam Heater (Round) | Roll Up Door | 1 | ||||||
| 776 | *776-1 | *7.5 TON PKG UNIT | YORK HEAT PUMP | ROOF EAST SIDE | AIR | 7.5 ton | 1 | |||
| 776 | *776-2 | *HEAT/VENT UNIT | YORK TEMPMASTER - CP45SW5IAF200460 | ROOF WEST SIDE | 1 | |||||
| 776 | *776-1-E | *EXHAUST FAN | GREENHECK - LUBE-100-3 | ROOF | AIR | 1 | ||||
| 776 | *776-2-E | *EXHAUST FAN | GREENHECK - CUBE-130-5 | ROOF | 1 | |||||
| 776 | *776-3-E | *EXHAUST FAN | AIRMASTER - ARDV-12 | ROOF | 1 | |||||
| 776 | *776-4-E | *EXHAUST FAN | Powerproof Vent - 737D | ROOF | 1 | |||||
| 824 | *824-1 | *Split System | AHU | 1ST FL W SIDE | 1 | |||||
| 824 | *824-1A | *Split System Condenser | Condenser | Roof | 1 | |||||
| 824 | 824-GUH-1 AND GUH-2 | GAS UNIT HEATER | MODINE HDS-100 | ATTIC | 2 | |||||
| 1000 | 1000-1 | 525 TON CHILLER | TRANE CVHF570 | 1ST FLOOR MECH ROOM | Water | centrifugal | 525 ton | 1 | ||
| 1000 | 1000-2 | 525 TON CHILLER | TRANE CVHF570 | 1ST FLOOR MECH ROOM | Water | centrifugal | 525 ton | 1 | ||
| 1000 | 1000-3 | 525 TON CHILLER | TRANE CVHF570 | 1ST FLOOR MECH ROOM | Water | centrifugal | 525 ton | 1 | ||
| 1000 | 1000-4 | 525 TON CHILLER | TRANE CVHE-050C-AC-2PB2602CA3A11CA1A000 | 1ST FLOOR MECH ROOM | Water | centrifugal | 525 ton | 1 | ||
| 1000 | *1000-1-1 | *AHU 7 | PENT FRAME D-8 | 125 HP / 87,000 CFM, 3,552 MBH Cooling | 1 | |||||
| 1000 | *1000-1-2 | *AHU 5 | PENT FRAME B-9 | 125 HP / 87,000 CFM, 2,574 MBH Cooling | 1 | |||||
| 1000 | *1000-1-3 | *AHU 9 | PENT FRAME D-9 | 125 HP / 73,000 CFM, 3,667 MBH Cooiling | 1 | |||||
| 1000 | *1000-1-4 | *AHU 10 | PENT FRAME B-9 | 125 HP / 73,000 CFM, 3,667 MBH Cooiling | 1 | |||||
| 1000 | *1000-1-5 | *AHU 6 | PENT FRAME C-9 | 125 HP / 87,000 CFM, 2,574 MBH Cooling | 1 | |||||
| 1000 | *1000-1-6 | *AHU 8 | PENT FRAME C-9 | 125 HP / 87,000 CFM, 3,552 MBH Cooling | 1 | |||||
| 1000 | *1000-1-7 | *AS-4 | TRANE - Trane Climate Changer Type 73 | 2ND FL NE EQ RM | 25 HP | 1 | ||||
| 1000 | *1000-1-8 | *AS-3 | TRANE - Trane Climate Changer Type 73 | 2ND FL SE EQ RM | 25 HP | 1 | ||||
| 1000 | *1000-1-9 | *AS-2 | TRANE - Trane Climate Changer Type 73 | 2ND FL SW EQ RM | 25 HP | 1 | ||||
| 1000 | *1000-1-10 | *AS-1 | TRANE - Trane Climate Changer Type 73 | 2ND FL NW EQ RM | 25 HP | 1 | ||||
| 1000 | *1000-1-11 | *AHU 15 HP | TRANE | 2ND FL COL C-7 CLNG | 1 | |||||
| 1000 | *1000-1-12 | *AHU 7.5 HP | TRANE | 2ND FL NE EQ RM | 1 | |||||
| 1000 | *1000-1-14 | *AHU #102 | NW CORNER | 3/4 HP / 1100 CFM, 22.5 MBH Cooling, 21.5 Heating | ||||||
| 1000 | *1000-1-15 | *AHU #104 | SUB ANTENNA COL C-5 | 3/4 HP / 1200 CFM, 27 MBH Cooling | 1 | |||||
| 1000 | *1000-1-17 | *AHU #107 | TOAC OFFICE | 3/4 HP / 1200 CFM, 25 MBH Cooling | 1 | |||||
| 1000 | *1000-1-18 | *AHU #103 | SUB LIFE SUPPORT | 3/4 HP / 1250 CFM, 31 MBH Cooling | 1 | |||||
| 1000 | *1000-1-19 | *AHU #101 | 1ST FL MER MEZZ | 15 HP / 12000 CFM, 167 MBH Heating | 1 | |||||
| 1000 | *1000-1-20 | *AHU # 100, 7.5 HP | TRANE MCCA021MAG0C0B | MECH ROOM MEZZ | 7.5 HP / 12000 FM | 1 | ||||
| 1000 | *1000-1-21 | *AHU #111 | S.E. COL D-15 | 5 HP / | 1 | |||||
| 1000 | * | *Room 114 Condenser | Trane TTA240E40RAA | AC Refrigeration Fence | 20 Tons | 1 | ||||
| 1000 | 1000-5-1 | COOLING TOWER | BALTMORE AIRCOIL COMPANY |
MOTOR EMERSON MODEL 6310-2RSJ/C3, HP=30, U084035202
| ROOF N | ~500 Tons | 1 | |
| 1000 | 1000-5-2 | COOLING TOWER | BALTMORE AIRCOIL COMPANY |
MOTOR EMERSON MODEL 6310-2RSJ/C3, HP=30, U084035202
| ROOF N | ~500 Tons | 1 | ||||||
| 1000 | 1000-6-1 | COOLING TOWER | BALTMORE AIRCOIL COMPANY | |||||
| MOTOR EMERSON MODEL 6310-2RSJ/C3, HP=30, U084035202 | ROOF S | ~500 Tons | 1 | |||||
| 1000 | 1000-6-2 | COOLING TOWER | BALTMORE AIRCOIL COMPANY | |||||
| MOTOR EMERSON MODEL 6310-2RSJ/C3, HP=30, U084035202 | ROOF S | ~500 Tons | 1 | |||||
| 1000 | *3RD FL SECURE SPACE-CONDENSER | DAIKIN RCSO20DYYYY | ROOF NW | ~20 Tons | 1 | |||
| 1000 | *3rd FL Secure SPACE AHU | DAIKIN AHU | 3rd Fl. West Mechanical Room | 7.5 HP / 7800 CFM, 20 Ton Total Cooling, 150 MBH Heating | 1 | |||
| 1000 | *1000-7 | *15 TON CHILLER | TRANE | SW CORNER | 15 ton | 1 | ||
| 1000 | *1000-8 | *15 TON CHILLER | TRANE | SW CORNER | 15 ton | 1 | ||
| 1000 | *1000-9 | *15 TON SPLIT SYS | LIEBERT | MER E SIDE | AIR | 15 ton | 1 | |
| 1000 | *1000-9-1 | *AHU | LIEBERT | 2ND FL COMP RM SE | AIR | 15 ton | 1 | |
| 1000 | *1000-11 | *3 TON SPLIT SYS | FREDRICH | TEST LAB 96-05A ROOF | AIR | 3 ton | 1 | |
| 1000 | *1000-11-1 | *AHU WALL HUNG | FREDRICH | TEST LAB 96-05A | 3 ton | 1 | ||
| 1000 | *1000-22 | *10 TON SPLIT SYS | TRANE | MAIN MECH ROOM ROOF | 10 ton | 1 | ||
| 1000 | *1000-22-1 | *AHU | TRANE | TEST SITE 62-26A ROOF | 10 ton | 1 | ||
| 1000 | *1000-1-1A | *AIR COMP | DEVIBLISS HUBO-5564 | MECH RM 1ST FLOOR | 1 | |||
| 1000 | *1000-1-2A | *AIR COMP | DEVIBLISS HUBO-5564 | PENTHOUSE | 1 | |||
| 1000 | 1000-1-1P | CONDENSER 1, 1500 GPM PUMP | WESTINGHOUSE, 40 HP | 1ST FLOOR MECH ROOM | 40 HP 1500 GPM | 1 | ||
| 1000 | 1000-1-2P | CONDENSER 3, 1500 GPM PUMP | WESTINGHOUSE, 40 HP | 1ST FLOOR MECH ROOM | 40 HP 1500 GPM | 1 | ||
| 1000 | 1000-1-3P | CONDENSER 4, 1500 GPM PUMP | GENERAL ELECTRIC, 40 HP | 1ST FLOOR MECH ROOM | 40 HP 1500 GPM | 1 | ||
| 1000 | 1000-1-4P | CONDENSER 2, 1500 GPM PUMP | BALDOR, 40 HP | 1ST FLOOR MECH ROOM | 40 HP 1500 GPM | 1 | ||
| 1000 | 1000-1-5P | CHILLED 4, 900 GPM PUMP | WESTINGHOUSE | 1ST FLOOR MECH ROOM | 900 GPM | 1 | ||
| 1000 | 1000-1-6P | CHILLED 1, 900 GPM PUMP | WESTINGHOUSE | 1ST FLOOR MECH ROOM | 900 GPM | 1 | ||
| 1000 | 1000-1-7P | CHILLED 2, 900 GPM PUMP | WESTINGHOUSE | 1ST FLOOR MECH ROOM | 900 GPM | 1 | ||
| 1000 | 1000-1-4P | CHILLED 3, 900 GPM PUMP | WESTINGHOUSE | 1ST FLOOR MECH ROOM | 900 GPM | 1 | ||
| 1000 | 1000-1-8P | 15 HP HW PUMP HPP-1 | CENTURY | 1ST FLOOR MECH ROOM MEZZ | 15 hp | 1 | ||
| 1000 | 1000-1-9P | 15 HP HW PUMP HPP-2 | US ELECTRIC | 1ST FLOOR MECH ROOM MEZZ | 15 hp | 1 | ||
| 1000 | *1000-7-1P | *CIRC. PMP | B/G | 1ST FL SW | ||||
| 1000 | *1000-7-2P | *CIRC. PMP | I/R | 1ST FL SW | ||||
| 1000 | *1000-7-3P | *CIRC. PMP | B/G | 1ST FL SW | ||||
| 1000 | *1000-1-E | *EXHAUST FAN E-106 | GREENBECK 44-BISW-41-1-II | |||||
| MOTOR TOSHIBA B0754113UM1101 | ROOF NE | 75 HP | ||||||
| 1000 | *1000-2-E | *EXHAUST FAN E-107 | MOTOR Greenheck 54-BISW-41-1-II | ROOF SE | 125 HP | |||
| 1000 | 1000-NGB-1 | NATURAL GAS BOILER | LOCHINVAR PBN2001 | PENTHOUSE | 2000 MBH (Input) | 1 | ||
| 1000 | 1000-NGB-2 | NATURAL GAS BOILER | LOCHINVAR PBN2001 | PENTHOUSE | 2000 MBH (Input) | 1 | ||
| 1000 | 1000-NGB-3 | NATURAL GAS BOILER | LOCHINVAR PBN2001 | PENTHOUSE | 2000 MBH (Input) | 1 | ||
| 1000 | 1000-NGB-4 | NATURAL GAS BOILER | LOCHINVAR PBN2001 | PENTHOUSE | 2000 MBH (Input) | 1 | ||
| 1000 | * | *Mini-Split Condenser | MITSUBISHI - PUY-A12NHA4 | PENTHOUSE-ELEVATOR MACH. ROOM | 1 Ton | 1 | ||
| 1000 | * | *Mini-SPLIT AHU | MITSUBISHI | PENTHOUSE-ELEVATOR MACH. ROOM | 1 Ton | 1 | ||
| 1000 | * | *15 Ton Split Condenser | TRANE - TTA180E400 | ROOF | 15 TONS | 2 | ||
| 1000 | * | *15 TON SPLIT AHU | TRANE - UCCAG14COAORU01200000CFC862AA0000000 | 4TH FLOOR CARRIER LAB | 15 TONS | 2 | ||
| 1000 | GARAGE DOOR HEATERS | 1ST FLOOR, NORTH ROLL-UP DOORS | 4 | |||||
| 1000 | GARAGE DOOR HEATERS | 1ST FLOOR, SOUTH ROLL-UP DOORS | 4 | |||||
| 1000 | * | *BATHROOM EXHAUST FANS | TRANE Utility Fan U12k4-BI | 4TH, NE ROOM 410, BATHROOM EXHAUST TO FLOORS 1 THRU 4 | 1 | |||
| 1000 | * | *BATHROOM EXHAUST FANS | TRANE Utility Fan U12k4-BI | 4TH SE, STORAGE ROOM, BATHROOM EXHAUST TO FLOORS 1 THRU 4 | 1 | |||
| 1000 | * | *BATHROOM EXHAUST FANS | TRANE Utility Fan U12k4-BI | 4TH NW, ROOM 425, BATHROOM EXHAUST TO FLOORS 1 THRU 4 | 1 | |||
| 1000 | * | *BATHROOM EXHAUST FANS | TRANE Utility Fan U12k4-BI | 4TH SW, ROOM 401, BATHROOM EXHAUST TO FLOORS 1 THRU 4 | 1 | |||
| *Penthouse Exhaust Fan | Centuri Master Ventsent QB200 | SW CORNER | 2 HP | 1 | ||||
| 1000 | NE ELEVATOR MR HW Heater | TRANE UHSA038S8AAAC | ROOF NE | 1 | ||||
| 1000 | * | *NE ELEVATOR MR Exhaust | EXHAUST FAN MOTOR CENTURY 4M864, FRAME L56CZ, 1/4 HP | ROOF NE | 1/4 HP | 1 | ||
| 1000 | NW ELEVATOR MR HW Heater | TRANE UHSA038S8AAAC | ROOF NW | 1 | ||||
| 1000 | * | *NW ELEVATOR MR Exhaust | EXHAUST FAN MOTOR CENTURY 4M864, FRAME L56CZ, 1/4 HP Penn Ventilator Company | ROOF NW | 1/4 HP | 1 | ||
| 1000 | 1000-NWF-1 | NW Freight Mini Split Evap | Daikin FTX18AXVJU | NW Freight Elevator MR | 1.5 Tons | 1 | ||
| 1000 | 1000-NWF-1-1 | NW Freight Mini Split Condenser | Daikin RX18AXVJU | North Roof | 1.5 Tons | 1 | ||
| 1000 | 1000-NWF-2 | NW Freight Mini Split Evap | Daikin FTX18AXVJU | NW Freight Elevator MR | 1.5 Tons | 1 | ||
| 1000 | 1000-NWF-2-1 | NW Freight Mini Split Condenser | Daikin RX18AXVJU | North Roof | 1.5 Tons | 1 | ||
| 1000 | SE ELEVATOR MR HW Heater | TRANE UHSA038S8AAAC | SE Roof | 1 | ||||
| 1000 | * | *SE ELEVATOR MR Exhaust | EXHAUST FAN MOTOR CENTURY 4M864, FRAME L56CZ, 1/4 HP, Greenheck SDF-20-24B | SE Roof | 1/4 HP | 1 | ||
| 1000 | SW Elevator SHAFT MR | TRANE UHSA038S8AAAC | SW Roof | 1 | ||||
| 1000 | SW Elevator SHAFT MR | Penn Ventilator Complany | SW Roof | 1/4 HP | ||||
| 1000 | * | *MITSUBISHI SPLIT CONDENSER | MXZ-5C42NAHZ | 1ST FLOOR C-SWIC | 3.5 Tons | 1 | ||
| 1000 | * | *MITSUBISHI SPLIT AHU/EVAPS | PCAA24KA7 | 1ST FLOOR C-SWIC | 2 Tons | 2 | ||
| 1000 | * | *Room 112B Air Handler with DX | TWE090D300AA | Room 112B | 7.5 Tons | 1 | ||
| 1000 | * | *Room 112B Condenser | TTA073D300AA | Room 112B Roof | 6 Tons | 1 | ||
| 1000 | * | *Room 112A Evaporator | Sanyo KMS1272 | Room 112A | 1 Ton | 1 | ||
| 1000 | * | *Room 112A Condenser | Mitsubishi MUY-GE12NA | Room 112A Roof | 1 Ton | 1 | ||
| 1000 | * | *Room 112 Evaporator | Friedrich-MW30C3F | Room 112 | 2.5 Tons | 1 | ||
| 1000 | * | *Room 112 Condenser 30,700 BTU's | Friedrich-MW30CF | Room 112 Roof | 2.5 Tons | 1 | ||
| 1000 | * | *Room 114 Condenser | Sanyo CM2472 | Room 114 | 2 Tons | 1 | ||
| 1000 | * | *Room 114 Evaporator | Sanyo KMS0972 | Room 114 Roof | 3/4 Ton | 2 | ||
| 1000 | *1000-23 | *MINI SPLIT SYSTEM CONDENSER | MITS. MXZ-3C3ONA2 | ROOF of Room 116 | 2.5 tons | 1 | ||
| 1000 | *1000-23-1 | *MINI SPLIT SYSTEM EVAPORATOR | MITS. MSZ-GL15NA | 1ST FL. ROOM 116 | 1.25 tons | 2 | ||
| 1000 | *1000-24 | *MINI SPLIT SYSTEM CONDENSER | MITS. MXZ-3C3ONA2 | ROOF of Room 116 | 2.5 tons | 1 | ||
| 1000 | *1000-24-1 | *MINI SPLIT SYSTEM EVAPORATOR | MITS. MSZ-GL15NA | 1ST FL. ROOM 116 | 1.25 tons | 2 | ||
| 1000 | *1000-25 | *MINI SPLIT SYSTEM | FREDRICH MW12Y3FM | 1ST FL. C/10211 SPACE | 1 Ton | 2 | ||
| 1000 | *1000-25-1 | *MINI SPLIT SYSTEM | FREDRICH MW09Y3FM | 1ST. FL. C/10211 SPACE | 3/4 Ton | 2 | ||
| 1000 | * | *MINI SPLIT CONDENSER | Daikin - RX36NMVJUA | SW Roof | 3 Tons | 2 | ||
| 1000 | * | *MINI SPLIT EVAPORATOR | DaikinFTX36NVJU | Room 429 | 3 Tons | 2 | ||
| 1000 | * | Liebert AHU | PX029UA1A8S068 | Room 471 | Air | 101 MBH | 2 | |
| 1000 | * | Liebert Condenser | MCL055E1ADT646 | South Roof | 101 MBH | 2 | ||
| 1000 | * | Liebert AHU | VS035ADA100793S | Room 473 | Air | 124.7 MBH | 2 | |
| 1000 | * | Liebert Condenser | MCS056E8ADR721 | South Roof | 124.7 MBH | 2 | ||
| 1000 | * | Liebert AHU | VS042ADA100010S | Rm. 475 | Air | 141.9 MBH | 2 | |
| 1000 | * | Liebert Condenser | MCM080E8ADR722 | South Roof | 141.9 MBH | 2 | ||
| 1000 | * | Liebert AHU | VS035ADA100794S | Rm. 477 | Air | 124.7 MBH | 2 | |
| 1000 | * | Liebert Condenser | MCM080E8ADR723 | South Roof | 124.7 MBH | 2 | ||
| 1000 | * | Liebert AHU | CR019RA | Rm. 477A | 8 Ton | 1 | ||
| 1000 | * | Liebert Condenser | MCS028 | South Roof | 8 Ton | 1 | ||
| 1000 | * | Liebert AHU | DS025 | Rm. 477A | 10 Ton | 1 | ||
| 1000 | * | Liebert Condenser | MCS056 | South Roof | 10 Ton | 1 | ||
| 1000 | * | Liebert AHU | PX029 | Rm. 473A | 5 Ton | 3 | ||
| 1000 | * | Liebert Condenser | MCM040 | South Roof | 5 Ton | 3 | ||
| 1000 | *1000-1-HCSC | Liebert AHU | PX029DA1A85016 | HCSC Lab - 3rd Floor | 105 MBH | 1 | ||
| 1000 | *1000-1-1-HCSC | Liebert Condenser | MCM040E1ADT474 | South Roof - Adjacent to SE Freight Elevator | 105 MBH | 1 | ||
| 1000 | *1000-2-HCSC | Liebert AHU | PX029DA1A85016 | HCSC Lab - 3rd Floor | 105 MBH | 1 | ||
| 1000 | *1000-2-1-HCSC | Liebert Condenser | MCM040E1ADT474 | South Roof - Adjacent to SE Freight Elevator | 105 MBH | 1 | ||
| 1000 | *1000-3-HCSC | Liebert AHU | PX029DA1A85016 | HCSC Lab - 3rd Floor | 105 MBH | 1 | ||
| 1000 | *1000-3-1-HCSC | Liebert Condenser | MCM040E1ADT474 | South Roof - Adjacent to SE Freight Elevator | 105 MBH | 1 | ||
| 1000 | *1000-4-HCSC | Liebert AHU | PX029DA1A85016 | HCSC Lab - 3rd Floor | 105 MBH | 1 | ||
| 1000 | *1000-4-1-HCSC | Liebert Condenser | MCM040E1ADT474 | South Roof - Adjacent to SE Freight Elevator | 105 MBH | 1 | ||
| 1032 | TTA180E300 | 7.5 TON CONDENSER | TRANE | BLDG.1032 EAST SIDE | 7.5 ton | 1 | ||
| 1032 | TTA180E300 | 7.5 TON CONDENSER | TRANE | BLDG. 1032 EAST SIDE | 7.5 ton | 1 | ||
| 1032 | *TWE180E300 | *15 TON AHU | TRANE | BLDG. 1032 MECHANICAL ROOM | 15 ton | 1 | ||
| 1032 | ALP210N-L02 | 210 BTU BOILER | ALPINE | BLDG.1032 MECHANICAL ROOM | 210,000 BTU | 1 |
* = YEAR ROUND OPERATION
TOTAL: 1124
* Indicates Year Round Operation Page &P of &N
WTR TRTMNT GLYC LIST
| SOW ATTACHMENT 2B OF HVAC MAINTENANCE AND REPAIR CONTRACT | 10/Dec/2021 | |||
| NSWCPD WATER TREATMENT LIST | ||||
| NOTE: This equipment list is subject to change due to system upgrades or equipment replacement. | ||||
| COOLING TOWER TREATMENT LIST | RECOMMENDED WATER TREATMENT | |||
| SITE | CLIENT | BUILDING | LOCATION | FREQUENCY |
| PNBC | NSWC | 4 | PENTHOUSE / UNIT 4-1-24 |
| PNBC | NSWC | 4 | PENTHOUSE / UNIT 4-1-25 |
| PNBC | NSWC | 77L | ROOF / UNIT 77L-1-8 |
| PNBC | NSWC | 1000 | ROOF UNIT / 1000-5-1&2 |
| PNBC | NSWC | 1000 | ROOF UNIT / 1000-6-1&2 |
| CHILLED WATER SYSTEMS TREATMENT LIST | RECOMMENDED WATER TREATMENT | |||
| SITE | CLIENT | BUILDING | LOCATION | FREQUENCY |
| PNBC | NSWC | 4 | PENTHOUSE | |
| PNBC | NSWC | 77L | CHILLER ROOM | |
| PNBC | NSWC | 87 | GROUND LEVEL | |
| PNBC | NSWC | 633 | TOACC AREA | |
| PNBC | NSWC | 633 | PENTHOUSE | |
| PNBC | NSWC | 1000 | MECH ROOM (NEW TOTAL = FOUR (4) CHILLERS) |
| HOT WATER SYSTEMS TREATMENT LIST | RECOMMENDED WATER TREATMENT | |||
| SITE | CLIENT | BUILDING | LOCATION | FREQUENCY |
| PNBC | NSWC | 633 | PENTHOUSE | |
| PNBC | NSWC | 1000 | MECH ROOM MEZZ | |
| PNBC | NSWC | 4 | PENTHOUSE | |
| PNBC | NSWC | 29 | MECHANICAL ROOM |
| BOILER WATER TREATMENT LIST | RECOMMENDED WATER TREATMENT | |||
| CLIENT | BUILDING | LOCATION | FREQUENCY | |
| PNBC | NSWC | 77H | BOILER ROOM EAST SIDE | |
| PNBC | NSWC | 77L | BOILER ROOM SOUTH WEST | |
| PNBC | NSWC | 77L | BOILER ROOM SOUTH WEST |
| GLYCOL SYSTEMS LIST | |||
| SITE | CLIENT | BUILDING | LOCATION |
| PNBC | NSWC | 4 | COMP ROOM 2nd FL / UNITS 4-3,4-4, & 4-5 |
| PNBC | NSWC | 4 | COMP OFFICE 1st FL / UNIT 4-7 |
| PNBC | NSWC | 4 | HOT WATER LOOP FOR ALL AHU's |
| PNBC | NSWC | 29 | ROOF / CHILLED WATER LOOP UNIT 29-1 |
| PNBC | NSWC | 77H | EAST SIDE / 77H-16 |
| PNBC | NSWC | 87 | GROUND LEVEL |
| PNBC | NSWC | 633 | TOACC AREA / 633-12 |
| PNBC | NSWC | 633 | PENTHOUSE CHILLED WATER LOOP |