This document appears to be a proposed layout for a parking lot expansion project at the U.S. Embassy in Lusaka, Zambia. The project involves expanding the existing staff parking areas west of the Chancery, north of the Utility Building, and the existing staff parking lot, covering a total of approximately 730 square meters of area. The layout includes details such as the number and placement of new parking spaces, the removal of existing trees, and the relocation of a signal manhole and light pole. The document provides structural notes with concrete and reinforcement specifications. This project is the subject of Solicitation Number PR12253735, issued by the Department of State, for the Parking Lot Expansion Project. The solicitation calls for the expansion of the parking lots, with a focus on the areas identified in the layout document.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1100024750 22000
R750
EXISTING
PROPOSED
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
2 3 4 5 6
STRUCTURAL
NOTES:
AutoCAD SHX Text Existing trees (4) to be removed
AutoCAD SHX Text Move curb
AutoCAD SHX Text existing Signal manhole
AutoCAD SHX Text light pole
AutoCAD SHX Text City Fire Hydrant
AutoCAD SHX Text No.
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
AMENDMENTS
AutoCAD SHX Text
DATE
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
REFERENCE DRAWINGS
AutoCAD SHX Text DRAWING No.
AutoCAD SHX Text
TITLE
AutoCAD SHX Text
APPROVALS HE DOES SO ENTIRELY AT HIS OWN RISK.
AutoCAD SHX Text
SHOULD THE CONTRACTOR PROCEED WITHOUT THE ABOVE
AutoCAD SHX Text
INFORMATION SHOWN ON THE DRAWING AND DIMENSIONS
AutoCAD SHX Text
CONTRACTOR TO CHECK AND VERIFY SUFFICIENCY OF
AutoCAD SHX Text
IMMEDIATELY REPORTED TO THE PROJECT MANAGER.
AutoCAD SHX Text
ANY OMMISIONS, DISCREPANCIES OR ERRORS TO BE
AutoCAD SHX Text
FIGURED DIMENSIONS ON DRAWINGS TO BE GIVEN PRIORITY
AutoCAD SHX Text
GENERAL NOTES:
AutoCAD SHX Text
BEFORE COMMENCING WORK.
AutoCAD SHX Text
OVER SCALING.
AutoCAD SHX Text 3.
AutoCAD SHX Text 2.
AutoCAD SHX Text 1.
AutoCAD SHX Text JOB No.:
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text DRG.No.:
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text E
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text G
AutoCAD SHX Text F
AutoCAD SHX Text
PROJECT DESCRIPTION:
AutoCAD SHX Text
LUSAKA STAFF PARKING
AutoCAD SHX Text
PROPOSED PARKING LAYOUT
AutoCAD SHX Text
WEST OF CHANCERY
AutoCAD SHX Text October 2023
AutoCAD SHX Text
C/NEC/P/2023/06
AutoCAD SHX Text 1:100
AutoCAD SHX Text
CHUMA
AutoCAD SHX Text
CHUMA
AutoCAD SHX Text
CHUMA
AutoCAD SHX Text 4 REINFORCEMENT COVER TO BE 40mm FOR BEAMS AND .
AutoCAD SHX Text
5 ALL DOWELS TO 16MM 400MM LONG.
AutoCAD SHX Text 3 SOLID CONCRETE BLOCKS TO HAVE MINIMUM 15Mpa .
AutoCAD SHX Text
1. ALL CONCRETE 25Mpa UNLESS STATED
AutoCAD SHX Text
2. ALL REINFORCEMENT TO BE HIGH TENSILE STEEL WITH
AutoCAD SHX Text A MINIMUM YIELD STRENGTH OF 450Mpa EXCEPT LINKS
AutoCAD SHX Text TO BE MILD STEEL 250MpA YIELD STRENGTH
AutoCAD SHX Text
COMPRESSIVE STRENGTH
AutoCAD SHX Text
AND 75MM WHERE CAST AGAINST EARTH