Proposed Lusaka Staff Parking temporal fencing details.pdf

PDF 168 KB Posted

Attached to
Parking Lot Expansion Project
Solicitation number
PR12253735
Issued by

About this file

The provided document appears to be a set of technical details for the construction of a temporary fence for a staff parking area at the U.S. Embassy in Lusaka, Zambia. The details include specifications for the fence materials, such as the diamond mesh, posts, horizontal tubes, and concrete foundation. Additionally, the document includes structural notes outlining requirements for the concrete, reinforcement, and other construction elements.

The document is related to a federal contract opportunity for the Parking Lot Expansion Project at the U.S. Embassy Lusaka. The solicitation (PR12253735) calls for the expansion of three existing parking lots, covering approximately 250, 240, and 240 square meters respectively. The work will involve the expansion of crushed stone, concrete, and grass areas in the current staff parking area and the lawn areas north of the Utility Building and west of the Chancery Building.

View the file

Other files

Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TYPICAL TEMPORAL FENCE

CONSTRUCTION

40X 40 X 2.5mm DIAMOND MESH

400mm Razor wire

100x 100 x2 Square Tube Post @ 2000

20Mpa Foundation Concrete

40x 80 x 2mm rectangular steel tube horizontals

50x 50mm tubes

40X40 SQ. Tube Post

30x30x1.6 SQ Tube frame

M10 Bolts and Nuts

150x 150mmx 3 base plate

40x 40mm Angle

TYPICAL TEMPORAL HOARDING

PANEL

40X 40 X 2.5mm DIAMOND MESH

SAFETY

SIGNAGE

STRUCTURAL

NOTES:

AutoCAD SHX Text No.

AutoCAD SHX Text

REVISIONS

AutoCAD SHX Text

AMENDMENTS

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

REFERENCE DRAWINGS

AutoCAD SHX Text DRAWING No.

AutoCAD SHX Text

TITLE

AutoCAD SHX Text

APPROVALS HE DOES SO ENTIRELY AT HIS OWN RISK.

AutoCAD SHX Text

SHOULD THE CONTRACTOR PROCEED WITHOUT THE ABOVE

AutoCAD SHX Text

INFORMATION SHOWN ON THE DRAWING AND DIMENSIONS

AutoCAD SHX Text

CONTRACTOR TO CHECK AND VERIFY SUFFICIENCY OF

AutoCAD SHX Text

IMMEDIATELY REPORTED TO THE PROJECT MANAGER.

AutoCAD SHX Text

ANY OMMISIONS, DISCREPANCIES OR ERRORS TO BE

AutoCAD SHX Text

FIGURED DIMENSIONS ON DRAWINGS TO BE GIVEN PRIORITY

AutoCAD SHX Text

GENERAL NOTES:

AutoCAD SHX Text

BEFORE COMMENCING WORK.

AutoCAD SHX Text

OVER SCALING.

AutoCAD SHX Text 3.

AutoCAD SHX Text 2.

AutoCAD SHX Text 1.

AutoCAD SHX Text JOB No.:

AutoCAD SHX Text

CHECKED:

AutoCAD SHX Text DRG.No.:

AutoCAD SHX Text

DESIGNED:

AutoCAD SHX Text

DRAWN:

AutoCAD SHX Text

REVISIONS

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text E

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text G

AutoCAD SHX Text F

AutoCAD SHX Text

PROJECT DESCRIPTION:

AutoCAD SHX Text

LUSAKA STAFF PARKING

AutoCAD SHX Text

TEMPORAL FENCING DETIALS

AutoCAD SHX Text October 2023

AutoCAD SHX Text

C/NEC/P/2023/03

AutoCAD SHX Text 1:30

AutoCAD SHX Text

CHUMA

AutoCAD SHX Text

CHUMA

AutoCAD SHX Text

CHUMA

AutoCAD SHX Text 4 REINFORCEMENT COVER TO BE 40mm FOR BEAMS AND .

AutoCAD SHX Text

5 ALL DOWELS TO 16MM 400MM LONG.

AutoCAD SHX Text 3 SOLID CONCRETE BLOCKS TO HAVE MINIMUM 15Mpa .

AutoCAD SHX Text

1. ALL CONCRETE 25Mpa UNLESS STATED

AutoCAD SHX Text

2. ALL REINFORCEMENT TO BE HIGH TENSILE STEEL WITH

AutoCAD SHX Text A MINIMUM YIELD STRENGTH OF 450Mpa EXCEPT LINKS

AutoCAD SHX Text TO BE MILD STEEL 250MpA YIELD STRENGTH

AutoCAD SHX Text

COMPRESSIVE STRENGTH

AutoCAD SHX Text

AND 75MM WHERE CAST AGAINST EARTH

Sheets and Views
new template nelson chuma-Layout2

File details come from the government source that posted it. Updated .