Project Drawings 1 of 3.pdf
PDF 12 MB Posted
- Attached to
- Y1DA--Project # 596-19-102 Construction to Renovate Building 39 for Transportation and Grounds.
- Solicitation number
- 36C24921R0056
About this file
This document provides details on a federal contract opportunity for construction services. Solicitation number 36C24921R0056 from the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 9 seeks proposals to renovate Building 39 for transportation and grounds purposes under project number 596-19-102. The opportunity type is listed as a solicitation. No further information is included on response dates, pricing terms, or other salient details regarding the required construction and renovation services.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 09 3013 TILING.pdf | ||
| A-401 Revised.pdf | ||
| CU 001 CU 002 CU 003.pdf | ||
| A-601 Revised.pdf | ||
| 07 7200 ROOF ACCESSORIES.pdf | ||
| 36C24921R0056 0002.docx | DOCX document | |
| Roof Pictures.pdf | ||
| Solicitation Questions and Answers.pdf | ||
| 36C24921R0056 0001.docx | DOCX document | |
| Site Visit Sign-In Sheet.pdf | ||
| Project Drawings 3 of 3.pdf | ||
| Project Specifications.pdf | ||
| Pricing Schedule.xlsx | XLSX spreadsheet | |
| Project Drawings 2 of 3.pdf | ||
| Past Performance Questionnaire.pdf | ||
| Statement of Work.pdf | ||
| 36C24921R0056_1.docx | DOCX document | |
| Wage Determination KY20210090 01-15-2021.pdf |
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Management
Office of Construction and Facilities
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
1101 VETERANS DRIVE, LEXINGTON, KY
RENOVATE B-39 FOR
TRANSPORTATION & GROUNDS
596-19-102 JRA Architects 3225 Summit Square Place Lexington KY 40509 859-252-6781
G-001
COVER SHEET
11/16/2020 FFE JRA
GENERAL
G-001 COVER SHEET
G-101 INFORMATION DRAWING
G-102 LOCATIONS AND LAYOUT RULES
G-103 LIFE SAFETY PLAN
CIVIL
CU-001 SITE & UTILITY PLAN
CU-002 PROFILE & DETAILS
CU-003 EROSION AND SEDIMENT CONTROL NOTES
STRUCTURAL
SB-101 SLAB PLAN
SB-501 STRUCTURAL DETAILS
SF-101 STRUCTURAL FRAMING PLAN
SF-501 STRUCTURAL FRAMING DETAILS
SF-502 STRUCTURAL FRAMING SECTIONS AND DETAILS
ARCHITECTURAL
A-001 DEMOLITION PLAN
A-002 HAZARDOUS MATERIAL DRAWING
A-101 FIRST FLOOR PLAN
A-102 MEZZANINE FLOOR PLAN
A-121 FIRST FLOOR REFLECTED CEILING PLAN
A-122 MEZZANINE REFLECTED CEILING PLAN
A-181 ROOF PLAN
A-201 BUILDING ELEVATIONS
A-301 BUILDING SECTIONS
A-302 BUILDING SECTIONS
A-351 WALL SECTIONS
A-401 INTERIOR DETAILS
A-501 PLAN DETAILS
A-531 ENLARGED SECTION DETAILS
A-601 DOOR AND WINDOW SCHEDULE AND DETAILS
A-602 WINDOW TYPES AND DETAILS
A-621 ROOM FINISH SCHEDULE
A-701 PARTITION TYPES AND DETAILS
FIRE PROTECTION
FX-100 FIRE SUPPRESSION PLAN - LOWER LEVEL
FX-101 FIRE SUPPRESSION PLAN - FIRST FLOOR
FX-102 FIRE SUPPRESSION PLAN - MEZZANINE
FX-103 FIRE SUPPRESSION PLAN - PENTHOUSE
FX-501 FIRE SUPPRESSION SECTIONS AND DETAILS
PLUMBING
P-100 PLUMBING LEGEND SHEET
PD-100 PLUMBING DEMOLITION PLAN - LOWER LEVEL
PD-101 PLUMBING DEMOLITION PLAN - FIRST FLOOR
PD-102 PLUMBING DEMOLITION PLAN - MEZZANINE
PL-100 PLUMBING NEW WORK PLAN - LOWER LEVEL
PL-101 PLUMBING NEW WORK PLAN - FIRST FLOOR
PL-102 PLUMBING NEW WORK PLAN - MEZZANINE
PL-501 PLUMBING DETAILS I
PL-502 PLUMBING DETAILS II
PL-601 PLUMBING SCHEDULES
PL-901 PLUMBING ISOMETRICS - SANITARY
PL-902 PLUMBING ISOMETRICS - DOMESTIC WATER
MECHANICAL
M-001 MECHANICAL LEGEND SHEET
MD-100 MECHANICAL DEMOLITION PLAN - LOWER LEVEL
MD-101 MECHANICAL DEMOLITION PLAN - FIRST FLOOR
MD-102 MECHANICAL DEMOLITION PLAN - MEZZANINE
MD-103 MECHANICAL DEMOLITION PLAN - ROOF
MH-100 MECHANICAL NEW WORK PLAN - LOWER LEVEL
MH-101 MECHANICAL NEW WORK PLAN - FIRST FLOOR
MH-102 MECHANICAL NEW WORK PLAN - MEZZANINE
MH-103 MECHANICAL NEW WORK PLAN - ROOF
MH-401 MECHANICAL SECTIONS
MH-501 MECHANICAL DETAILS
MH-502 MECHANICAL DETAILS
MH-601 MECHANICAL SCHEDULES
MH-602 MECHANICAL SCHEDULES
MH-603 MECHANICAL SCHEDULES
MH-604 MECHANICAL CONTROLS
MH-605 MECHANICAL CONTROLS
MH-606 MECHANICAL CONTROLS
ELECTRICAL
E-001 ELECTRICAL SYMBOLS & SCHEDULES
E-002 ELECTRICAL DETAILS
E-003 ELECTRICAL SCHEDULES & DETAILS
ED-100 LOWER LEVEL - DEMOLITION
ED-101 FIRST FLOOR PLAN - DEMOLITION
ED-102 MEZZANINE FLOOR PLAN - DEMOLITION
ED-103 ROOF PLAN - DEMOLITION
EL-100 LOWER LEVEL - LIGHTING
EL-101 FIRST FLOOR PLAN - LIGHTING
EL-102 MEZZANINE FLOOR PLAN - LIGHTING
EP-100 LOWER LEVEL - POWER & SYSTEMS
EP-101 FIRST FLOOR PLAN - POWER & SYSTEMS
EP-102 MEZZANINE FLOOR PLAN - POWER & SYSTEMS
EP-103 ROOF PLAN - POWER & SYSTEMS
ET-001 TECHNOLOGY DETAILS
ET-100 SITE PLAN - TECHNOLOGY
ET-101 FIRST FLOOR PLAN - TECHNOLOGY
ET-102 MEZZANINE FLOOR PLAN - TECHNOLOGY
ET-401 ENLARGED FLOOR PLAN - TECHNOLOGY
-��⇡✓◆⇠�⌧.��/⇡-⇠-◆�⌫+⇡-⇠◆⇠0⇡�1�-⇡⌅��⌫. /-◆�2�0�-#⌫⇡⌅⌫��3�◆,+⌅⌫ +-⇡4��⇠56�*.%�.%)&
N
CONTRACTOR STAGING AREA -
COORDINATE WITH C.O.R.
Revisions: Date:
E001
1t
BRICK
CMU
CONCRETE (SECTION)
CONCRETE OR PRECAST CONCRETE
(PLAN / ELEVATION)
CRUSHED STONE
SOLID WOOD
(TREATMENT AS NOTED)
WOOD (FINISH)
EARTH
ALUMINUM
STEEL
BATT INSULATION RIGID INSULATION
ACOUSTICAL CEILING PANEL
E.I.F.S. (ELEVATION) SOLID SURFACE
LIMESTONE
PLYWOOD
CERAMIC OR QUARRY TILE
PRECAST CONCRETE
(SECTION)
E.I.F.S. (SECTION)
ROOM NAME & ROOM NUMBER
NAME
NUMBER
ROOM NUMBER (RCP PLANS)
NUMBER
DOOR OPENING INDICATOR
NUMBER
EXTERIOR WINDOW OPENING INDICATOR
PARTITION TYPE INDICATOR
NUMBER
OR LETTER
EQUIPMENT INDICATOR
NUMBER
OR LETTER
NORTH ARROW
BUILDING NORTH
TRUE NORTH
COLUMN GRID (NEW)
* COLUMN GRID (EXIST)
BUILDING SECTION
WALL SECTION
SECTION
SHEET
NUMBER
SECTION
SHEET
NUMBER
DETAIL SECTION
SECTION
SHEET
NUMBER
BENCHMARK, LEVEL,
OR SPOT ELEVATION
KEYNOTE (SPEC REFERENCE)04 2000.A1 DETAIL CALLOUT
OR ENLARGED
PLAN
DRAWING
NUMBER
SHEET
NUMBER
NEW DOOR AND FRAME EXISTING DOOR AND FRAME
TO REMAIN
A
CEILING INDICATOR
TYPE
HEIGHT
ROOM
NAME
GYPSUM BOARD
(TYPE AS NOTED)
CENTER LINE
C.J.
CONTROL JOINT
DEMOLITION PLAN NOTE
PLAN NOTE
REMOVE DOOR AND FRAME
ITEM TO BE REMOVED
ITEM TO REMAIN
A-101
A-101
A-101
A-101
INTERIOR WINDOW OPENING INDICATORA01
ACT-1 / 18' - 0"
ACCENT WALL INDICATORP-1
MATERIAL INDICATORL-1
6" 6"
EXAMPLE 'A'
8"
8"
EXAMPLE 'B'
EXAMPLE 'C'
'B' 'D'
'C''A'
'E'
'F'
'H ''G'
EXAMPLE 'D'
'B' 'D'
'A'
'E'
'B'
'D'
'A'
'E'
EXAMPLE 'E'
'E' OR 'F'
EXAMPLE 'F'
ALIGN
SEE PART.
TYPES FOR
WALL
THICKNESS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Management
Office of Construction and Facilities
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
1101 VETERANS DRIVE, LEXINGTON, KY
RENOVATE B-39 FOR
TRANSPORTATION & GROUNDS
596-19-102 JRA Architects 3225 Summit Square Place Lexington KY 40509 859-252-6781
G-101
INFORMATION DRAWING
11/16/2020 FFE JRA
RCP REINFORCED CONCRETE PIPE
RD ROOF DRAIN
REF REFERENCE
REFRIG REFRIGERATOR
REINF REINFORCED
REQD REQUIRED
RESIL RESILIENT
REV REVISION
RGSTR REGISTER
RH RIGHT HAND
RL RAIN LEADER
RM ROOM
RND ROUND
RO ROUGH OPENING
ROW RIGHT OF WAY
S SOUTH
SAB SOUND ATTENUATION BLANKET
SAC SUSPENDED ACOUSTICAL
CEILING
SAT SUSPENDED ACOUSTICAL TILE
SC SOLID CORE
SCH SCHEDULE
SD STORM DRAIN
SECT SECTION
SF SQUARE FOOT
SHLF SHELF
SHT SHEET
SHWR SHOWER
SIM SIMILAR
SOG SLAB ON GRADE
SP SOUND PROOF
SPEC SPECIFICATION
SPKR SPEAKER
SS SANITARY SEWER
SST STAINLESS STEEL
STA STATION
STC SOUND TRANSMISSION
COEFFICIENT
STD STANDARD
STL STEEL
STOR STORAGE
STR STAIR
STRUCT STRUCTURAL
SUSP SUSPENDED
SY SQUARE YARD
SYM SYMMETRICAL
SYS SYSTEM
T TREAD
T&G TONGUE AND GROOVE
TB TACK BOARD
TC TOP OF CURB
TEL TELEPHONE
TEMP TEMPORARY
TER TERRAZZO
THK THICK
THR THRESHOLD
TOP TOP OF PAVEMENT
TOS TOP OF STEEL
TOW TOP OF WALL
TP TOILET PARTITION
TPH TOILET PAPER HOLDER
TSTAT THERMOSTAT
TYP TYPICAL
UL UNDERWRITERS
LABORATORIES
UNO UNLESS NOTED OTHERWISE
UR URINAL
VB VAPOR BARRIER
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VNB VINYL BASE
VT VINYL TILE
VTR VENT THROUGH ROOF
VWC VINYL WALL COVERING
W WEST
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WD WOOD
WH WATER HEATER
WP WATERPROOF
WR WATER RESISTANT
WSCT WAINSCOT
WT WEIGHT
WWF WOVEN WIRE FABRIC
LAM LAMINATE
LAV LAVATORY
LBL LABEL
LG LONG
LH LEFT HAND
LKR LOCKER
LL LIVE LOAD
LOC LOCATION
LP LOW POINT
LT LIGHT
LTL LINTEL
LWT LIGHT WEIGHT
MACH MACHINE
MAINT MAINTENANCE
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MB MARKER BOARD
MECH MECHANICAL
MEMB MEMBRANE
MET METAL
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MIR MIRROR
MISC MISCELLANEOUS
MO MASONRY OPENING
MOD MODULAR
MOV MOVING
MT MOUNT
MTD MOUNTED
MUL MULLION
N NORTH
N/A NOT APPLICABLE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
OA OVERALL
OBS OBSCURE
OC ON CENTER
OD OUTSIDE DIAMETER (DIM)
OF OWNER FURNISHED
OFCI OWNER FURNISHED /
CONTRACTOR INSTALLED
OFOI OWNER FURNISHED / OWNER
INSTALLED
OH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OZ OUNCE
PA PUBLIC ADDRESS
PAR PARALLEL
PC PRECAST
PCF POUNDS PER CUBIC FOOT
PED PEDESTAL
PERF PERFORATED
PFM PREFINISHED METAL
PL PLATE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLMG PLUMBING
PNL PANEL
PNTD PAINTED
POL POLISHED
PR PAIR
PREFAB PREFABRICATED
PREFIN PREFINISHED
PROP PROPERTY
PRPL PROPERTY LINE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT POINT
PTD PAPER TOWEL DISPENSER
PTN PARTITION
PVC POLYVINYL CHLORIDE
PVMT PAVEMENT
PWD PLYWOOD
QT QUARRY TILE
QTR QUARTER
R RISER
RA RETURN AIR
RAD RADIUS
RB RUBBER BASE
EHD ELECTRIC HAND DRYER
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
EMER EMERGENCY
ENCL ENCLOSURE
ENL ENLARGED
ENTR ENTRANCE
EP ELECTRICAL PANEL
EQ EQUAL
EQPT EQUIPMENT
EST ESTIMATE
EWC ELECTRIC WATER COOLER
EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR
FA FIRE ALARM
FB FLAT BAR
FCO FLOOR CLEAN OUT
FD FLOOR DRAIN
FDN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISHED FLOOR
FFE FINISHED FLOOR ELEVATION
FFL FINISHED FLOOR LINE
FHC FIRE HOSE CABINET
FIN FINISH
FL FLOOR
FLASH FLASHING
FLUOR FLUORESCENT
FND FEMININE NAPKIN DISPOSAL
FOC FACE OF CONCRETE
FOF FACE OF FINISH
FOM FACE OF MASONRY
FOS FACE OF STUD
FPRF FIREPROOF
FS FULL SIZE
FT FOOT OR FEET
FTG FOOTING
FV FIELD VERIFY
GA GAUGE
GALV GALVANIZED
GB GRAB BAR
GFI GROUND FAULT INTERRUPTER
GI GALVANIZED IRON
GL GLASS
GND GROUND
GR GRADE
GRTG GRATING
GWB GYPSUM WALL BOARD
GYP GYPSUM
HB HOSE BIBB
HBD HARDBOARD
HC HOLLOW CORE
HDWD HARDWOOD
HDWR HARDWARE
HGT HEIGHT
HM HOLLOW METAL
HNDRL HANDRAIL
HORIZ HORIZONTAL
HP HIGH POINT
HTG HEATING
HTR HEATER
HVAC HEATING/VENTILATION/AIR
CONDITIONING
HW HOT WATER
ID INSIDE DIAMETER (DIM)
IF INSIDE FACE
IN INCH
INCIN INCINERATOR
INCL INCLUDE
INSUL INSULATION
INT INTERIOR
INV INVERT
JAN JANITOR
JST JOIST
JT JOINT
KIT KITCHEN
KO KNOCK OUT
KP KEY PAD
L LENGTH
LAB LABORATORY
# POUND OR NUMBER
& AND
-- - -- CENTERLINE
@ AT
A/C AIR CONDITIONING
AB ANCHOR BOLT
AC ACRE
ACOUS ACOUSTICAL
AD AREA DRAIN
ADD ADDENDUM
ADJ ADJUSTABLE
ADJAC ADJACENT
AESS ARCHITECTURALLY EXPOSED
STRUCTURAL STEEL
AFF ABOVE FINISHED FLOOR
AGGR AGGREGATE
ALT ALTERNATIVE
ALUM ALUMINUM
ANOD ANODIZED
AP ACCESS PANEL
APPROX APPROXIMATE
ARCH ARCHITECTURAL
ASB ASBESTOS
ASPH ASPHALT
ATTEN ATTENUATION
BC BACK OF CURB
BD BOARD
BITUM BITUMINOUS
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BLKT BLANKET
BM BEAM
BOT BOTTOM
BPL BEARING PLATE
BRG BEARING
BRK BRICK
BSMT BASEMENT
BUR BUILT UP ROOFING
CAB CABINET
CB CATCH BASIN
CEM CEMENT
CER CERAMIC
CFM CUBIC FEET PER MINUTE
CG CORNER GUARD
CHB CHALK BOARD
CJ CONTROL JOINT
CLG CEILING
CLKG CAULKING
CLO CLOSET
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CMW CASEWORK / MILLWORK
CNTR COUNTER
CO CLEAN OUT
COL COLUMN
CONC CONCRETE
CONSTR CONSTRUCTION
CONT CONTINUOUS
CONV CONVENTIONAL
CORR CORRIDOR
CPT CARPET
CR CARD READER
CSMT CASEMENT
CT CERAMIC TILE
CTR CENTER
CTSK COUNTERSUNK
DBL DOUBLE
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DH DOUBLE HUNG
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DISP DISPENSER
DL DEAD LOAD
DN DOWN
DR DOOR
DS DOWNSPOUT
DSP DRY STANDPIPE
DWG DRAWING
DWR DRAWER
E EAST
EA EACH
EB EXPANSION BOLT
A WORK SHOWN ON THE DRAWINGS SHALL BE BASE BID UNLESS SPECIFICALLY NOTED TO BE BY ALTERNATE BID.
B FIELD VERIFY EXISTING FINISH FLOOR ELEVATIONS PRIOR TO STARTING CONSTRUCTION. MATCH NEW FLOOR ELEVATION
WITH EXISTING UNLESS NOTED OTHERWISE.
C DIMENSIONS TO EXISTING CONSTRUCTION ARE TO FINISHED SURFACE. DIMENSIONS TO NEW CONSTRUCTION ARE TO STRUCTURAL CENTERLINE, FACE OF CONCRETE OR MASONRY CONSTRUCTION, OR TO FINISH FACE OF FRAMED MEMBERS UNLESS NOTED OTHERWISE. FIELD VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR TO STARTING WORK AND NOTIFY ARCHITECT IMMEDIATELY IF DISCREPANCIES ARE FOUND BETWEEN CONTRACT DOCUMENTS AND ACTUAL FIELD
CONDITIONS.
D WHERE A FIXED DIMENSION IS SHOWN ON AN ACCESSIBLE FIXTURE OR ACCESSORY, THAT ITEM SHALL BE INSTALLED EXACTLY AS DIMENSIONED. REFER TO THE ACCESSORY MOUNTING LEGEND FOR MOUNTING HEIGHTS.
E DO NOT SCALE DRAWINGS. REFER DIMENSION QUESTIONS TO ARCHITECT FOR INTERPRETATION.
F DOOR AND FRAME NUMBERS CORRESPOND TO RESPECTIVE ROOM NUMBERS. IN ROOMS WITH MULTIPLE OPENINGS, A
SUFFIX HAS BEEN ADDED TO DOOR NUMBERS, I.E., A101-B.
G LOCATE INSIDE FACE OF DOOR FRAME JAMBS 6 INCHES FROM FINISH FACE OF ADJACENT WALLS UNLESS NOTED
OTHERWISE.
H COORDINATE EQUIPMENT WORK WITH MANUFACTURERS AND SUPPLIERS TO INSURE PROPER ROUGH-IN CLEARANCES FOR
INSTALLATION, USE AND MAINTENANCE.
I REFER TO LIFE SAFETY DRAWINGS FOR FIRE-RATED FLOOR, WALL, CEILING AND ROOF LOCATIONS. INSTALL FIRESTOPPING
AT PENETRATIONS IN RATED CONSTRUCTION AND AT TOPS OF RATED WALLS.
J PROTECT EXISTING SURFACES TO REMAIN THAT ARE NOT INCLUDED IN SCOPE OF WORK BUT THAT ARE WITHIN AREAS OF
CONSTRUCTION ACTIVITY.
K PATCH, REPAIR AND RESTORE EXISTING FINISHES AND SURFACES TO "AS NEW CONDITION" AS REQUIRED TO MATCH SURROUNDING MATERIALS OR TO PROVIDE APPROPRIATE SUBSTRATE PRIOR TO INSTALLING NEW FINISHES. AREAS NOTED TO BE PATCHED OR REPAIRED ON THE DRAWINGS ARE GIVEN FOR REFERENCE AND SHALL NOT BE INTERPRETED TO LIMIT
THE SCOPE OF WORK.
L PROVIDE SEALANT BETWEEN DISSIMILAR MATERIALS SUCH AS GYPSUM BOARD AND MASONRY, MASONRY AND CONCRETE, COUNTERTOPS AND WALLS, ETC.
M TOOTH NEW MASONRY INTO EVERY OTHER COURSE OF EXISTING MASONRY UNLESS OTHERWISE INDICATED. PROVIDE HORIZONTAL ANCHORS BETWEEN NEW AND EXISTING MASONRY AT CONDITIONS THAT PROHIBIT TOOTHED-TYPE CONSTRUCTION. HORIZONTAL JOINTS OF NEW MASONRY SHALL MATCH EXISTING UNLESS OTHERWISE INDICATED. NEW
MASONRY BOND SHALL MATCH EXISTING UNLESS OTHERWISE INDICATED.
N REPAIR AND PATCH SPRAYED FIRE-RESISTIVE AND FIRESTOP MATERIALS WHERE DAMAGED DUE TO INSTALLATION OF NEW
MATERIALS TO RESTORE SPECIFIED FIRE RATING.
O PROVIDE CONTROL JOINTS (C.J.) IN GYPSUM BOARD WALL CONSTRUCTION AS INDICATED. WHERE NOT SHOWN, PROVIDE MAXIMUM SPACING BETWEEN JOINTS OF 30'-0." VERIFY FINAL CONTROL JOINT LOCATIONS WHETHER OR NOT INDICATED ON
THE DRAWINGS WITH ARCHITECT PRIOR TO STARTING WORK.
P INTERIOR STUD SPACING SHALL BE MAXIMUM 16" ON CENTER UNLESS NOTED OTHERWISE.
Q PROVIDE MOLD AND MOISTURE RESISTANT GYPSUM BOARD ON ALL INTERIOR FACE OF EXTERIOR WALLS, WALLS WITH OPERABLE PLUMBING FIXTURES, AND WALLS WITHIN 4'-0" OF DRINKING FOUNTAINS OR WATER COOLERS.
R PROVIDE FINISHED END PANELS, FILLERS, SUPPORTS, ETC. REQUIRED FOR A COMPLETE CABINETRY INSTALLATION.
PROVIDE CUTOUTS, ACCESS PANELS AND REMOVABLE COMPONENTS AS REQUIRED BY NEW OR EXISTING CONDITIONS SUCH
AS ELECTRICAL OUTLETS, JUNCTION BOXES, CLEANOUTS, ETC.
S VERIFY MOUNTING HEIGHTS OF ACCESSORIES, EQUIPMENT, DOOR HARDWARE, CASEWORK, ETC., AND PROVIDE SOLID 2X SUPPORT WOOD BLOCKING FASTENED TO FRAMING MEMBERS AS REQUIRED TO SUPPORT WEIGHT AND USE OF ITEMS.
WHERE MOUNTING HEIGHTS ARE NOT INDICATED, MOUNT ITEMS IN ACCORDANCE WITH RECOGNIZED INDUSTRY STANDARDS, COORDINATE LOCATIONS WITH MANUFACTURER OR SUPPLIER AND REFER MOUNTING HEIGHT QUESTIONS TO ARCHITECT
FOR INTERPRETATION.
T AT ALL EXTERIOR ENVELOPE CONDITIONS, SOLID WOOD BLOCKING INDICATED SHALL BE CONTINUOUS, U.N.O.
U PROVIDE SEALANT BETWEEN HOLLOW METAL FRAME PERIMETERS AND SURROUNDING WALL CONSTRUCTION UNLESS
OTHERWISE INDICATED.
V PROVIDE SEALANT BETWEEN INTERIOR AND EXTERIOR WINDOW AND STOREFRONT FRAME PERIMETERS AND SURROUNDING
CONSTRUCTION UNLESS OTHERWISE INDICATED.
W DO NOT BEGIN WORK THAT MAY REQUIRE COORDINATION, SUCH AS CEILING INSTALLATION, PRIOR TO FINAL SUBMITTAL OF MECHANICAL AND ELECTRICAL COORDINATION DRAWINGS TO ARCHITECT NOR PRIOR TO RESOLUTION AND APPROVAL OF
COORDINATION ISSUES.
X REFER TO STRUCTURAL DRAWINGS FOR FOOTING, UNDERSLAB DRAINAGE AND BACKFILL REQUIREMENTS.
Y REFER TO LANDSCAPE AND CIVIL DRAWINGS FOR SITE ELEMENTS AND IMPROVEMENTS ADJACENT TO BUILDING EXTERIOR.
Z REFER TO CIVIL DRAWINGS FOR FOUNDATION DRAINS AND STORM DRAINAGE REQUIREMENTS.
2018 KENTUCKY BUILDING CODE - (BASED ON THE 2015 INTERNATIONAL BUILDING CODE)
2009 ICC/ANSI A117.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES
2015 INTERNATIONAL MECHANICAL CODE
2012 INTERNATIONAL ENERGY CONSERVATION CODE
2013 KENTUCKY PLUMBING LAW, REGULATIONS, & CODE (KRS Chapter 318 and 815 KAR Chapter 20)
2012 NFPA 1 - UNIFORM FIRE CODE (AS DIRECTED BY 2013 KENTUCKY STANDARDS OF SAFETY)
2013 NFPA 13 - STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS
2013 NFPA 14 - STANDPIPE, HOSE SYSTEMS
2012 NFPA 54 - NATIONAL FUEL GAS CODE
2017 NFPA 70 - NATIONAL ELECTRICAL CODE
2013 NFPA 72 - NATIONAL FIRE ALARM AND SIGNALING CODE
2018 NFPA 101 - LIFE SAFETY CODE (VA FACILITIES)
GB-03-01 SEAOK - SPECIAL INSPECTION GUIDELINES, THIRD EDITION, MARCH 2007
THE ABOVE IS ONLY REPRESENTATIVE OF THE MANY CODES AND STANDARDS CURRENTLY USED IN THE KENTUCKY; AND, IS FOR REFERENCE ONLY. FOR SPECIFIC APPLICATIONS NOT LISTED ABOVE, CONTACT THE OFFICE OF HOUSING, BUILDINGS AND CONSTRUCTION, DIVISION OF BUILDING CODES
ENFORCEMENT AT (502) 573-0373 OR REFER TO CHAPTER 35 OF THE KBC.
PG-18-13 VA BARRIER FREE DESIGN STANDARD
FOR VA PROJECTS, ENFORCE NFPA CODES ABOVE SUPERCEDE IBC FOR FIRE PROTECTION AND LIFE SAFETY, REFER TO IBC ONLY WHERE NFPA IS SILENT.
- CAUTION: DUE TO THE POSSIBLE APPLICATION OF APPLIED FINISHED – THICKNESS OF WHICH MAY VARY BETWEEN FLOOR AND CEILING AND IS NOT ACCOUNTED FOR (EXCEPT AS INDICATED BY “FOF” OR “CLEAR”) BY THE DIMENSION SHOWN ON THE FLOOR PLANS – THE CONTRACTOR MUST ADJUST, AS NECESSARY, THE FLOOR PLAN DIMENSIONS TO REFLECT THE ACTUAL DIMENSIONS FOUND AT PLANE OF THE CEILING.
4. WHERE DIMENSIONS ARE NOT PROVIDED ON FLOOR PLANS, TO LOCATE DOOR OPENINGS, APPLY THE FOLLOWING RULES, IN ORDER, TO DETERMINE
THE LOCATION OF DOOR OPENINGS:
A. DOOR OPENINGS MAY BE DIMENSIONED ON DRAWINGS OTHER THAN THE FLOOR PLANS. REFER TO THE SECTIONS, ELEVATIONS, DETAILS, AND
DOOR SCHEDULE NOTES FOR ADDITIONAL DIMENSIONAL INFORMATION.
B. WHERE THE HINGE-SIDE OF A DOOR IS SHOWN ADJACENT TO A WALL-OR WALLS-PERPENDICULAR TO THE WALL IN WHICH THE DOOR OPENING
OCCURS:
- EXAMPLE ‘A’: AT DOORS OCCURRING IN METAL FRAMED GYPSUM BOARD PARTITIONS, LOCATE THE HINGE-SIDE OF THE DOOR 6 INCHES FROM THE FACE (EXCLUSIVE OF APPLIED FINISHES) OF THE CLOSEST PERPENDICULAR WALL OR PARTITION ASSEMBLY.
- EXAMPLE ‘B’: AT DOORS OCCURRING IN WALLS OF CONCRETE MASONRY UNIT CONSTRUCTION, LOCATE THE HINGE-SIDE OF THE DOOR FINISHED OPENING 10 INCHES FROM THE FACE (EXCLUSIVE OF APPLIED FINISHES) OF THE CLOSEST PERPENDICULAR WALL OR PARTITION ASSEMBLY.
C. WHERE DOOR OCCURS NOT ADJACENT TO A PERPENDICULAR WALL AND EITHER “DIM E” OR “DIM F” IS 16’-0” OR LESS, LOCATE DOOR UTILIZING THE
FOLLOWING MINIMUM DIMENSIONS (EXAMPLE ‘C’):
- DIMENSION A = 18 INCHES MIN
- DIMENSION B = 12 INCHES MIN
- DIMENSION C = DOOR WIDTH + 2 INCHES MINIMUM
- DIMENSION D = 4 INCHES MIN AT METAL FRAMED GYP BD PARTITIONS OR-EVEN MULTIPLE OF L CMU MODULE PLUS 2 INCHES AT CONCRETE
MASONRY UNIT WALLS
- DIMENSIONS E AND F = AS SHOWN ON PLANS
- DIMENSION G = 36 INCHES MIN
- DIMENSION H = 60 INCHES MIN
- IF SPACE ALLOWS, CENTER DOOR IN WALL SHOWN ON THE DRAWINGS SO THAT EITHER “DIM A” EQUALS “DIM C” OR “DIM B” EQUALS “DIM D”
D. IF “DIM E” IN DIAGRAMS SHOWN IS LESS THAN THE SUM OF 2 TIMES THE DOOR WIDTH PLUS 20 INCHES, LOCATE DOOR SO THAT MINIMUMS STATED BY NOTE NO 4C ABOVE FOR “DIM A”, “DIM B”, AND “DIM D” ARE MET – MAXIMIZING “DIM A” AND MINIMIZING “DIM D” TO THE EXTENT POSSIBLE (EXAMPLE ‘D’).
E. WHERE DOOR IS SHOWN LOCATED IN A LARGE EXPANSE OF OPEN WALL (“DIM E” AND “DIM F” IN DIAGRAM BELOW BOTH EXCEED 16’-0”), PLACE DOOR AT APPROXIMATE LOCATION SHOWN ON THE PLANS. WHERE DOOR OCCURS IN CMU WALL, PLACE DOOR AT APPROXIMATE LOCATION SHOWN WHILE
MINIMIZING “CUT” OR PARTIAL CMU MODULES ADJACENT TO THE JAMBS (EXAMPLE ‘E’).
5. WHERE WALLS AND/OR PARTITIONS OF UNEQUAL THICKNESS ABUT, ALIGN EXPOSED FACES, UNLESS OTHERWISE NOTED (EXAMPLE ‘F’)
1. EXCEPT WHERE DIRECTED TO PLACE ITEMS OF THE WORK AT THE “APPROXIMATE LOCATION SHOWN,” DO NOT SCALE DRAWINGS FOR DIMENSIONAL
INFORMATION.
2. ALL ELEMENTS OF THE DRAWINGS MAY NOT BE DRAWN TO EXACT SCALE. ALL DIMENSIONS REQUIRED ARE SHOWN (OR MAY BE DERIVED FROM THOSE SHOWN OR NOTED) ON THE FLOOR PLANS, DETAIL PLANS, ELEVATIONS, SECTIONS, SCHEDULES, CONFIGURATION DETAILS, AND SPECIFICATIONS. SEE THE NOTES BELOW AND SYMBOLS ON SHEET G-101 FOR DIMENSIONING CONVENTIONS USED ON THIS PROJECT.
3. EXCEPT WHERE SPECIFICALLY NOTED TO THE CONTRARY, ALL DIMENSIONS SHOWN ON THE ARCHITECTURAL DRAWINGS CONFORM TO THE
FOLLOWING CONVENTIONS:
A. DIMENSIONS UTILIZING THE “CENTERLINE” SYMBOL ARE MEASURED TO:
- STRUCTURAL OR DIMENSIONAL GRID LINES.
- CENTERLINE OF CONCRETE OR CONCRETE MASONRY UNIT WALLS (EXCLUSIVE OF FURRING OR APPLIED FINISHES HAVING THICKNESS). REFER TO THE ARCH PLANS AND SECTIONS, THE STRUCTURAL DRAWINGS, OR PARTITION SCHEDULE TO DETERMINE THE THICKNESS OF CONCRETE OR
CONCRETE MASONRY UNIT WALLS.
- CENTERLINE OF PARTITION ASSEMBLY (EXCLUSIVE OF ANY APPLIED FINISHES HAVING THICKNESS WHICH MAY BE ADDED TO SUCH WALLS) AT PARTITIONS FRAMED WITH METAL STUDS. REFER TO “PARTITION SCHEDULE” TO DETERMINE THICKNESS OF EACH PARTITION TYPE.
- CENTERLINE OF DOOR, WINDOW, OR LOUVER OPENING.
- CENTERLINE OF EQUIPMENT OR FURNISHING.
- CENTERLINE OF OTHER FEATURES AS INDICATED.
B. REFER TO SHEET G-101 FOR SYMBOL USED TO INDICATE CENTERLINE DIMENSION.
C. DIMENSIONS UTILIZING THE “CLEAR” DESIGNATION ARE MEASURED TO:
- FACE OF CONCRETE OR CONCRETE MASONRY UNIT WALL (EXCLUSIVE OF APPLIED FINISHES HAVING THICKNESS OR FURRING WHICH MAY BE ADDED
TO THE FACE OF SUCH WALLS).
- FACE OF PARTITION ASSEMBLY (EXCLUSIVE OF ANY APPLIED FINISHES HAVING THICKNESS WHICH MAY BE ADDED TO SUCH WALL) AS DEFINED BY THE PARTITION SCHEDULE. UNLESS NOTED AS A “FACE OF FINISH” OR “CLEAR” DIMENSION (SEE NOTE ‘E’ BELOW), DIMENSIONS ARE NOT MEASURED TO THE FACE OF APPLIED FINISH. REFER TO THE “PARTITION SCHEDULE” TO DETERMINE THE THICKNESS OF EACH PARTITION TYPE.
- INSIDE EDGE OF FINISHED DOOR OPENING. REFER TO THE “DOOR SCHEDULE” FOR ADDITIONAL DIMENSIONAL INFORMATION.
- DIMENSION OR WORK POINT AS INDICATED ON RELATED ARCH. DETAIL PLAN, SECTION, ELEVATION, LAYOUT OR CONFIGURATION DETAIL, OR
CONSTRUCTION DETAIL.
D. WHERE “FACE OF FINISH" OR “CLEAR” DIMENSIONS ARE SPECIFICALLY NOTED, THE DIMENSION IS MEASURED TO:
- FINISH FACES AT THE MOST NARROW OR CONSTRICTED POINTS OF SECTION WHERE DIMENSION IS SHOWN, WHEN THE DIMENSION OCCURS ACROSS AN OPEN SPACE. IN THIS CASE, A “FACE OF FINISH” DIMENSION IS EQUIVALENT TO A “CLEAR” DIMENSION.
- FINISH FACES AT THE WIDEST OR MOST EXPANSIVE POINTS OF THE SECTION THE DIMENSION IS SHOWN WHEN THE DIMENSION OCCURS ACROSS AN
OBJECT OR GROUP OF OBJECTS.
E. WHERE “EQUAL” DIMENSIONS ARE USED ON REFLECTED CEILING PLANS TO LOCATE CEILING GRID WORK POINTS, MEASURE DIMENSIONS TO:
- EDGE OF THE INDICATED CEILING AT THE FACE OF THE ADJACENT APPLIED FINISH MEASURED AT THE PLANE OF THE CEILING.
A IN ADDITION TO ALL KEYNOTES SHOWN, CASEWORK MFR(S). SHALL PROVIDE FINISHED ENDS AT ALL EXPOSED SURFACES.
B PROVIDE IN-WALL BLOCKING FOR ALL WALL/TALL CABINETS. ALL WOOD BLOCKING TO BE FIRE TREATED.
C PROVIDE 4" HIGH SIDE SPLASHES AT ALL COUNTERTOPS ADJACENT TO WALLS OR OTHER VERTICAL SURFACE.
D PROVIDE ALL FILLERS, APRONS, CLOSURES, TRIM, ETC. AS REQ'D. FOR A COMPLETE INSTALLATION.
E PROVIDE 1" RADIUS ON ALL OUTSIDE, EXPOSED CORNERS OF COUNTERTOPS.
F U.N.O., ALL BASE CABINETS ARE 24" DEEP. U.N.O., ALL WALL CABINETS ARE 12" DEEP.
G VERIFY ALL OWNER-FURNISHED EQUIPMENT SIZES WITH OWNER PRIOR TO FABRICATION OF CASEWORK.
H CONTRACTOR TO COORDINATE WITH COR FOR GROMMET SPACING AT ALL CASEWORK PRIOR TO FABRICATION.
A COORDINATE DEMOLITION WORK WITH NEW WORK. REMOVE ADDITIONAL EXISTING ITEMS AS REQUIRED TO PERFORM
NEW WORK.
B REFER TO WORK RESTRICTIONS IN THE PROJECT MANUAL. CLOSELY FOLLOW THE PROJECT MANUAL REQUIREMENTS FOR THE LOCATIONS AND TYPES OF BARRICADES, WORKING HOURS, AND NOTIFICATIONS TO THE OWNER. COORDINATE
DEMOLITION TO MAINTAIN PROTECTION OF THE EXISTING BUILDING.
C REFER TO THE PROJECT MANUAL SECTIONS ENTITLED "EXECUTION" AND "SELECTIVE DEMOLITION."
D REFER TO THE MECHANICAL, ELECTRICAL, PLUMBING, AND STRUCTURAL DRAWINGS AND COORDINATE DEMOLITION WORK
WITH ALL DISCIPLINES.
E COORDINATION ALL DEMOLITION WORK WITH PROJECT MANUAL SECTIONS ENTITLED "INFECTION CONTROL PROCEDURES" AND "INTERIM LIFE SAFETY MEASURES." DO NOT REMOVE AND TRANSPORT MATERIALS IN A MANNER THAT WOULD BE
UNSAFE TO PATIENTS AND STAFF.
F SURFACES ADJACENT TO AREAS OF DEMOLITION WHICH ARE AFFECTED BY THE WORK SHALL BE PATCHED AND FINISHED
TO MATCH ADJACENT SURFACES.
G ALL DEMOLITION SHALL BE DISPOSED OF IN A MANNER ACCEPTABLE TO LOCAL AND STATE REGULATORY AGENCIES.
H CONTRACTOR SHALL PROVIDE TEMPORARY PARTITIONS TO AVOID MIGRATION OF DUST INTO ADJACENT OCCUPIED
AREAS.
I ALL EQUIPMENT AND UTILITIES IN THIS BUILDING ARE TO BE DEMOLISHED AND REMOVED OFF SITE UNLESS OTHERWISE SPECIFIE AND STIPULATED ON THE DRAWINGS. THE BUILDING WAS DECOMMISSIONED SEVERAL YEARS AGO AND WAS VACATED. NOT ALL EQUIPMENT, DUCTWORK, PIPING, CABLING, WIRING, IS NOTED OR CALLED OUT IN THE BID PACKAGE. IT IS HIGHLY RECOMMENDED THAT PROSPECTIVE BIDDERS VISIT THE SITE TO REVIEW EXISTING CONDITIONS AND DECOMMISSIONED EQUIPMENT AND UTILITIES TO BE REMOVED, AS WELL AS THE LARGE AMOUNT OF LEAD PAINT TO BE ABATED OR ENCAPSULATED. NO CHANGE ORDERS WILL BE RECEIVED OR APPROVED THAT PERTAIN TO DEMOLITION OF EXISTING EQUIPMENT INSIDE THIS BUILDING OR TO LEAD PAINT ABATEMENT OR ENCAPSULATION. UPON REQUEST, THE OWNER MAY PROVIDE COPIES OF THE LIMITED AS-BUILTS FOR THIS BUILDING, WHICH DESCRIBE SOME, BUT NOT ALL, OF
THE ABANDONED OR DECOMMISSIONED EQUIPMENT AND UTILITIES.
A REFER TO FINISH PLANS, REFLECTED CEILING PLANS, INTERIOR ELEVATIONS, ROOM FINISH SCHEDULE, & FINISH MATERIAL
SCHEDULE FOR FINISH MATERIAL LOCATIONS & INFORMATION.
B REFER TO CASEWORK DRAWINGS FOR LAMINATE AND SOLID SURFACE LOCATIONS.
C PAINT NEW & EXISTING HOLLOW METAL DOORS, DOOR FRAMES AND LINTELS EXPOSED TO VIEW IN FINISHED AREAS AND
AT EXTERIOR LOCATIONS UNLESS OTHERWISE INDICATED.
D PAINT NEW & EXISTING STEEL COLUMNS, BEAMS, STRUCTURE, ETC., EXPOSED TO VIEW IN FINISHED AREAS UNLESS
OTHERWISE INDICATED.
E PAINT NEW & EXISTING GRILLES TO MATCH COLOR OF THE WALLS IN WHICH THEY ARE LOCATED, UNLESS NOTED
OTHERWISE.
F FINISH SOFFITS, BULKHEADS, AND SIMILAR CONDITIONS TO MATCH SURROUNDING SURFACES UNLESS OTHERWISE INDICATED. ONLY VERTICAL FACES OF SOFFITS TO BE PAINTED WITH WALL COLOR - HORIZONTAL SURFACES TO BE
PAINTED CEILING WHITE, FLAT.
G IN STAIRWELLS, PAINT NEW & EXISTING STEEL STAIR AND LANDING PARTS EXPOSED TO VIEW INCLUDING RISERS AND TREADS, STRINGERS, UNDERSIDE OF STAIR STRUCTURE, HANDRAILS, WALL BRACKETS, COMPONENTS VISIBLE FROM
EXTERIOR, ETC., U.N.O.
H PROVIDE FINISHES BEHIND FIXED EQUIPMENT SUCH AS CABINETRY, CASEWORK, CHALK AND TACKBOARDS, LOCKERS, ETC.
J ALIGN FLOOR FINISH TRANSITIONS AT DOOR LOCATIONS WITH CENTERLINE OF DOOR SUCH THAT TRANSITION MATERIALS
ARE NOT VISIBLE FROM EITHER SIDE WHEN DOOR IS IN CLOSED POSITION.
K FLOORING NOT NOTED AS ACCENT AREAS SHALL RECEIVE FIELD FLOORING - SEE FINISH MATERIAL SCHEDULE AND ROOM
FINISH SCHEDULE FOR ADDITIONAL DETAILS.
L FOR FLOOR TRANSITIONS SHOWN, REFER TO DETAILS ON A-621
M ALL FLOORING SHALL EXTEND UNDER KNEE SPACES AND COUNTERS.
N WALLS NOT NOTED AS ACCENT PAINT SHALL RECEIVE FIELD PAINT, P-2.
P INSIDE CORNER OF TILE WALLS SHALL RECEIVE SEALANT JOINT IN LIEU OF GROUT, U.N.O.
A VERIFY SIZE, LOCATION AND NUMBER OF ROOF PENETRATIONS INCLUDING VENTS, PIPES, CURBS, ROOF DRAINS, CONDUITS, �ETC. PROVIDE NEW FLASHING AND SEAL PENETRATIONS WHETHER OR NOT INDICATED ON THE DRAWINGS.
B COMPLETE WORK ABOVE ROOF, SUCH AS MASONRY, WELDING, MASONRY RESTORATION, ETC., PRIOR TO STARTING
ROOFING WORK.
C VERIFY AND MAINTAIN ROOF SLOPES AND DRAINAGE PATTERNS. TEST FOR AND CORRECT ANY PONDING CONDITIONS.
D REPAIR AND REPLACE ROOFING SYSTEM OR STRUCTURE DAMAGED BY IMPROPER STORAGE, CONSTRUCTION ACTIVITIES, OR LACK OF ADEQUATE TEMPORARY PROTECTION. THIS ALSO INCLUDES INTERIOR DAMAGE TO FINISHES, EQUIPMENT, FURNISHINGS, ETC., RESULTING FROM LEAKS.
E NEW BLOCKING SHALL BE PRESERVATIVE-TREATED WOOD.
F PAINT EXTERIOR LADDERS, BRACKETS, ETC., U.N.O.
A REFER TO FLOOR PLANS FOR LOCATIONS OF ALL INTERIOR PARTITION CONTROL JOINTS.
B PROVIDE CONTROL JOINTS (C.J.) IN GYPSUM BOARD WALL CONSTRUCTION AS INDICATED. WHERE NOT SHOWN, PROVIDE MAXIMUM SPACING BETWEEN JOINTS OF 30'-0." VERIFY FINAL CONTROL JOINT LOCATIONS WHETHER OR NOT INDICATED
ON THE DRAWINGS WITH ARCHITECT PRIOR TO STARTING WORK.
C ALL CURVED SURFACES TO RECEIVE LEVEL 5 GYPSUM BOARD FINISH.
D ALL GYPSUM PARTITIONS GREATER THAN 15'-0" OF EXPOSED HEIGHT, INCLUDING STAIR WALLS, SHALL RECEIVE LEVEL 5
GYPSUM BOARD FINISH.
E REFER TO A-701 FOR THE DEFLECTION TRACK DETAIL TO BE USED AT ALL PARTITIONS CONNECTED TO STRUCTURE OR
BRACED TO STRUCTURE.
F PROVIDE 5/8" TYPE X GYPSUM BOARD UNLESS NOTED OTHERWISE.
G PROVIDE MOLD AND MOISTURE RESISTANT GYPSUM BOARD ON THE INTERIOR FACE OF ALL EXTERIOR WALLS AND WITHIN
4'-0" IN ALL DIRECTIONS OF ALL OPERABLE PLUMBING FIXTURES.
H PROVIDE TILE BACKING PANELS WHERE TILE IS INDICATED - REFERE TO THE FINISH SCHEDULE AND INTERIOR ELEVATIONS.
STOP BACKING PANELS 1" BELOW TOP OF TILE.
J INTERIOR STUD SPACING SHALL BE MAXIMUM 16" ON CENTER UNLESS NOTED OTHERWISE.
K GAUGE, SPACING, AND PERFORMANCE REQUIREMENTS OF METAL STUDS SHALL BE DETERMINED BY SPECIFICATION, UNO.
A CENTER CEILING GRIDS WITHIN ROOMS EACH DIRECTION UNLESS NOTED OTHERWISE.
B LOCATE CEILING GRIDS WITHIN ROOMS SUCH THAT BORDERS CONTAIN NOT LESS THAN 1/2 TILE WIDTH, UNLESS OTHERWISE
INDICATED.
C CENTER PENETRATIONS IN ACOUSTICAL CEILING SYSTEMS WITHIN INDIVIDUAL CEILING PANELS, SUCH AS SPRINKLER HEADS, DIFFUSERS, LIGHT FIXTURES, ETC., UNLESS OTHERWISE INDICATED.
D PAINT EXPOSED GYPSUM BOARD AND PLASTER CEILING SURFACES CEILING WHITE-FLAT, UNLESS OTHERWISE INDICATED.
E PROVIDE CONTROL JOINTS (C.J.) IN GYPSUM BOARD CEILING CONSTRUCTION AS INDICATED. WHERE NOT SHOWN, PROVIDE MAXIMUM SPACING BETWEEN JOINTS OF 30'-0." VERIFY FINAL CONTROL JOINT LOCATIONS WITH ARCHITECT PRIOR TO
STARTING WORK WHETHER OR NOT INDICATED ON THE DRAWINGS.
F CEILING ACCESS DOORS INDICATED ARE NOT INTENDED TO LIMIT NUMBER OF PANELS REQUIRED. PANEL QUANTITY SHALL BE SUFFICIENT TO PROVIDE REQUIRED ACCESS WHETHER OR NOT INDICATED ON THE DRAWINGS. VERIFY FINAL LOCATIONS
WITH ARCHITECT PRIOR TO STARTING WORK.
G REFER TO FINISH PLANS FOR ADDITIONAL CEILING FINISH INFORMATION.
H REFER TO ELECTRICAL LIGHTING DRAWINGS FOR CEILING-MOUNTED LIGHT FIXTURE TYPES AND QUANTITIES.
J REFER TO MECHANICAL DRAWINGS FOR CEILING-MOUNTED DIFFUSERS, GRILLE TYPES AND QUANTITIES.
K REFER TO FIRE PROTECTION DRAWINGS FOR SPRINKLER HEAD TYPES AND QUANTITIES. HEADS HAVE BEEN INTENTIONALLY
OMITTED FROM REFLECTED CEILING PLANS FOR CLARITY.
A REFER TO WALL SECTIONS AND INTERIOR PARTITION TYPES FOR ADDITIONAL NOTES REGARDING TYPICAL WALL
CONSTRUCTION.
B MOUNT ANY INTERIOR SIGNAGE ON LATCH SIDE OF DOOR.
C ALL FIRE RATED DOORS SHALL BE CATEGORY "A" POSITIVE PRESSURE RATED COMPLYING WITH THE REQUIREMENTS OF
UL 10C TESTING. ADDITIONAL INTUMESCENT SEALS SHALL NOT ACCEPTABLE.
D PROVIDE CYLINDERS AND CORES FOR ALL DOOR HARDWARE CAPABLE OF BEING CHANGED AND KEYED TO THE OWNER'S
MASTER KEYING SYSTEM.
E ALL INTERIOR H.M. DOOR FRAMES, SHALL BE PAINTED P-1, U.N.O.
F ALL INTERIOR WOOD DOORS SHALL BE STAINED TO MATCH L-1, U.N.O.
G PROVIDE SEALANT BETWEEN HOLLOW METAL FRAME PERIMETERS AND SURROUNDING WALL CONSTRUCTION UNLESS
OTHERWISE INDICATED.
H GROUT FULL NEW HOLLOW METAL DOOR FRAMES IN MASONRY WALL CONSTRUCTION.
J SPOT GROUT NEW HOLLOW METAL DOOR FRAMES IN GYPSUM BOARD WALL CONSTRUCTION.
K WHERE A FIRE RATING IS INDICATED ON THE DOOR SCHEDULE, HARDWARE AND DOOR ASSEMBLY COMPONENTS SHALL
MEET THE REQUIREMENTS OF THAT LABEL.
L DOOR AND FRAME NUMBERS CORRESPOND TO RESPECTIVE ROOM NUMBERS. IN ROOMS WITH MULTIPLE OPENINGS, A
SUFFIX HAS BEEN ADDED TO DOOR NUMBERS, I.E., A101-B.
M LOCATE INSIDE FACE OF DOOR FRAME JAMBS 6 INCHES FROM FINISH FACE OF ADJACENT WALLS UNLESS NOTED
OTHERWISE.
N INSTALL CONTROL JOINTS AT ONE JAMB ON BOTH SIDES OF DOOR FRAMES WHICH DO NOT TERMINATE AT THE CEILING
PLANE.
P AT DOORS SHOWN WITH GLASS LITES, BOTTOM OF GLASS MUST BE NO HIGHER THAN 43" WHEN INSTALLED.
E
D
IM
. O N
P
LA
N
DIM. ON PLAN
5�⌧⌅�⌥
WHEN ELEMENT IS COMPLETELY DIMENSIONED ON REFLECTED CEILING PLAN
LOCATE ITEM AS INDICATED WHEN SHOWN DIMENSIONED BY REFLECTED CEILING
PLAN, ENLARGED REFLECTED CEILING PLAN, OR DETAIL
SPECIFIC DIMENSIONS SHOWN BY REFLECTED CEILING PLANS, ELEVATIONS, OR
DETAILS TAKE PRECEDENCE OVER TYPICAL LOCATION RULES
E Q
E Q
EQ EQ
5�⌧⌅��
WHEN NOT DIMENSIONED, BUT SHOWN CENTERED
LOCATE ITEM CENTERED IN SPACE (OR CEILING PLANE) WHEN SHOWN (BUT NOT
DIMENSIONED) GRAPHICALLY AT APPROXIMATE CENTER OF SPACE
EQ EQ
5�⌧⌅�
WHEN OFF CENTER IN SPACE BUT CENTERED ON ADJACENT ELEMENT
LOCATE ITEMS CENTERED ON ADJACENT OPENING, ELEMENT, OR FEATURE WHEN
SHOWN (BUT NOT DIMENSIONED) OFF-CENTER IN OVERALL SPACE BUT CENTERED
AGAINST ADJACENT ELEMENT
E Q
E Q
5�⌧⌅�⌦
WHEN ALIGNED WITH OTHER FEATURES
LOCATE ITEMS (LIGHT FIXTURES, SPRINKLER HEADS, DEVICES, ETC.) ALIGNED
WITH ADJACENT ITEMS FOR WHICH DIMENSIONS OR RULES ARE PROVIDED.
VISUAL ALIGNMENT IS CRITICAL. THE CONTRACTOR SHALL SELECT ONE ITEM IN
EACH LINE (ON BASIS OF TOLERANCE, SEQUENCE OF CONSTRUCTION, TRADE, OR
OTHER CRITERIA) TO SERVE AS THE ALIGNMENT BENCHMARK.
E Q
E
Q LOCATION (IN THIS DIRECTION) OF ONE ITEM
IN LINE IS ESTABLISHED BY DIMENSION OR
OTHER RULE (RULE NO. 3 SHOWN)
ACTUAL LINE OF ALIGNMENT DETERMINED BY
SELECTING ONE ITEM AS BENCHMARK; OTHER
ITEMS ARE LOCATED TO ALIGN WITH
BENCHMARK ITEM, SPACED EQUALLY.
DIM. ON PLAN
5�⌧⌅�+
ALIGN WITH FEATURES SHOWN DIMENSIONED ELSEWHERE IN SPACE
LOCATE ITEMS ALIGNED WITH OTHER ITEMS SHOWN DIMENSIONED ELSEWHERE IN
SPACE (OR CEILING PLANE)
D
IM
O
N P
LA
N
ALIGNMENT BASE ON
DIMENSIONED BEYOND
DIM. ON PLAN
5�⌧⌅�0
LOCATE ELEMENTS SYMMETRICALLY
LOCATE ITEMS ALIGNED WITH OTHER ITEMS SHOWN DIMENSIONED ELSEWHERE IN
SPACE (OR CEILING PLANE)
CENTERLINES OF
SPACE OR PLANE
EQ EQ
D
IM
O
N P
LA
N
E Q
E Q
5�⌧⌅�4
WHEN NOT DIMENSIONED BUT OCCURS IN SQUARE PANEL
LOCATE ITEMS (LIGHT FIXTURES, SPRINKLER HEADS, DEVICES, ETC.) AT CENTER
OF PANEL ON SQUARE GRID CEILINGS
E Q
E Q
EQ EQ
5�⌧⌅�/
WHEN NOT DIMENSIONED BUT OCCURS IN RECTANGULAR PANEL
LOCATE ITEMS (LIGHT FIXTURES, SPRINKLER HEADS, DEVICES, ETC.) AT CENTER
OF SHORT PANEL DIRECTION AND 1/4, 1/2, OR 3/4 POINT OF LONG PANEL
DIRECTION
E Q
E Q
1x EQ. 3x EQ.
EQ EQ
" M
A X
. A T
C O
U N
TE
R
S
M A
X . 4
8"
" M
A X
. A T
C O
U N
TE
R
S
M A
X . 4
8"
M A
X . 4
0"
" M
IN
MIRROR SOAP
DISPENSER
PAPER TOWEL
DISPENSER
" M
IN
M A
X . 4
8"
/4
TOILET PAPER
DISPENSER
TOILET
PAPER
HOLDER
SANITARY
NAPKIN
DISPOSAL
24"
M A
X
MIN.
15"
" M
A X
. A T
C O
U N
TE
R
S
SANITARY
NAPKIN
DISPENSER
F.E.C.
TO
H
A N
D
LE
BRACKET
MOUNTED F.E.
ACCESSIBLE
COAT HOOK
MOP
SINK
MOP / BROOM
HOLDER
ELECTRIC
HAND
DRYER
SWITCHES / DEVICES
VISUAL FIRE ALARM
LIGHT SWITCH
THERMOSTAT
CONV.
OUTLET
M
IN
24"
LAVATORY
M A
X
STANDARD
HEIGHT URINAL
SIGN FOR DIRECTION TO &
INFORMATION ABOUT
SPACES
WALL SIGN FOR
IDENTIFICATION OF
PERMANENT
ROOMS & SPACES
W/ 18" x 18" CLEAR
FLR. SPACE
LATCH SIDE OF
DOOR
T.
O
. S P
O U
T
32"
MIN. @
RECESSED
AREAS
STANDARD
HEIGHT
ELECTRIC WATER
COOLER
T.
O
. S P
O U
T
32"
MIN. @
RECESSED
AREAS
ACCESSIBLE
HEIGHT
ELECTRIC WATER
COOLER
M
IN
T.
O
. S P
O U
T
60"
MIN. @
RECESSED
AREAS
ACCESSIBLE
HEIGHT ELECTRIC
HI/LO WATER
COOLER
T.
O
. S P
O U
T
" M
IN
Administration
Purchasing
SIGNAGE LOCATION &
MOUNTING HEIGHT
30" CLR.
EQ EQ
30" CLR.
EQ EQ
ACCESSIBLE
HEIGHT URINAL
T.P., URINAL
SCREEN OR
FINISHED
WALL
SURFACE
T.P., URINAL
SCREEN OR
FINISHED
WALL
SURFACE
,⌧�-�6!"�⌃6=��5⌅��⇧!⇤�⇧⇥⇥⌅���56⌅��-��!�6!"�8⌅6"8��
��6⌧⌅��⇧⇥⇥⌅���56⌅�C�⇤⌅⇢6⇥⌅C�⇧!⇤�⌅D�6,-⌅!��-��!�6!"�8⌅6"8��
,⌧�-�6!"�⌃6=��5⌅��⇧!⇤�⇧⇥⇥⌅���56⌅��-��!�6!"�8⌅6"8��
A!��⌅↵���-⌅�6�⌅-���8� !�-⇧?�!����⌅�⇧,,⌧6⇥⇧�⌧⌅�����8⌅�,5�@⌅⇥�B
A!��⌅↵���-⌅�6�⌅-���8� !�-⇧?�!����⌅�⇧,,⌧6⇥⇧�⌧⌅�����8⌅�,5�@⌅⇥�B
NOTE: NOT TO BE
USED BELOW GRAB
BARS
T O
B A
S E
LI
N
E O
F
H
IG
H E
S T
A C
T
IL
C H
A R
A C
T E
R
8" 10"
" M
A X
. F O
R C
O N
TR
O
LS
6" MAX.
9"
8" MIN.
BABY
CHANGING
STATION
3' -1
1/
2"
TP, WALL, OR
OBSTRUCTION
WHERE OCCURS
TPH
MOUNTING
AREA
6"
1/
2"
7" TO 9"
ACCESSIBLE
WATER CLOSET
60" CLR. MIN.
FND MOUNTING
AREA
(NOTE: VERIFY DOOR
SWING CLEARANCE
BEFORE
INSTALLATION)
60" CLR.
TPH
MOUNTING
AREA
FND MOUNTING AREA
(NOTE: VERIFY DOOR
SWING CLEARANCE
BEFORE
INSTALLATION)
6"
32" CLR.
EQ EQ
STANDARD
WATER CLOSET
TP, WALL, OR
OBSTRUCTION
WHERE OCCURS
60" CLR.
12" 24"
17" 43"
54" MIN.
40"
5"
12"
6"
TSCD
MOUNTING
AREA
7" TO 9"
TSCD
MOUNTING
AREA
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Management
Office of Construction and Facilities
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
1101 VETERANS DRIVE, LEXINGTON, KY
RENOVATE B-39 FOR
TRANSPORTATION & GROUNDS
596-19-102 JRA Architects 3225 Summit Square Place Lexington KY 40509 859-252-6781
G-102
LOCATIONS AND LAYOUT RULES
11/16/2020 FFE JRA
A THE G-SERIES OF DRAWINGS ESTABLISH AND COORDINATE THE FINISHED
APPEARANCE AND LOCATION OF ALL EXPOSED ELEMENTS. THE G-SERIES
DRAWINGS TAKE PRECEDENCE FOR THE FINISHED APPEARANCE AND LOCATION OF
ALL PARTS OF THE WORK.
EXCEPTION: DIMENSIONED LOCATIONS SHOWN ON DRAWINGS OF OTHER
DISCIPLINES SHALL GOVERN ONLY WHERE THE FOLLOWING CONDITIONS OCCUR:
A. SPECIFICALLY AND INDIVIDUALLY INDICATED BY SYMBOL, KEYED NOTE, OR
NOTATION ON THE ARCHITECTURAL DRAWINGS.
B. OCCURRING WITHIN A ROOM OR OTHER IDENTIFIABLE SPACE FOR WHICH
ARCHITECTURAL SHEET OF SCHEDULE NOTES INDICATE THAT DIMENSIONS
PROVIDED ELSEWHERE SHALL GOVERN.
B THE PURPOSE OF THIS SHEET IS TO ILLUSTRATE THE TYPICAL RULES WHICH
GOVERN THE LOCATION, CONFIGURATION IN RELATIONSHIP TO OTHER ELEMENTS
OF THE WORK, AND FINISHED ALIGNMENT OF ALL ITEMS OCCURRING ON PLANS AND
REFLECTED CEILING PLANS OF THE PROJECT.
C THE A-SERIES FLOOR PLANS, REFLECTED CEILING PLANS, SECTIONS, ELEVATIONS,
AND DETAILS ILLUSTRATE DIMENSIONED LOCATION OF MANY, BUT NOT ALL,
EXPOSED PARTS OF THE WORK. APPLY THE LAYOUT RULES SHOWN ON THIS SHEET
– IN ORDER – TO DETERMINE THE LOCATION OF THE EXPOSED PART OF THE WORK.
A. WHEN UNIQUELY AND SPECIFICALLY DIMENSIONED ON THE A-SERIES PLANS,
SECTIONS, OR ELEVATIONS (OR COMBINATION THEREOF), LOCATE AS DIMENSIONED.
B. IF NOT SHOWN, OR SHOWN BUT NOT DIMENSIONED, BY THE A-SERIES PLANS OR
ELEVATIONS, LOCATE AS INDICATED BY THE APPLICABLE RULE.
D REFER TO THE “GENERAL NOTES” FOR ADDITIONAL NOTES WHICH APPLY TO THE
ENTIRE PROJECT.
A IT IS THE INTENT OF THE DESIGN THAT ALL ITEMS SHOWN MOUNTED AT TYPICAL
HEIGHTS BE ACCESSIBLE TO PERSONS WITH DISABILITIES.
B THE PURPOSE OF THIS SHEET IS TO ILLUSTRATE TYPICAL MOUNTING HEIGHTS AND –
WHERE APPLICABLE – TYPICAL MINIMUM OR MAXIMUM CLEARANCES AND/OR TYPICAL
MOUNTING CONFIGURATIONS FOR A VARIETY OF ITEMS. CAUTION: THIS SHEET MAY
ILLUSTRATE ITEMS OR CONFIGURATIONS WHICH DO NOT OCCUR AS PART OF THE WORK
OF THIS PROJECT. REFER TO THE PLANS, ELEVATIONS, SECTIONS, DETAILS AND
SCHEDULES TO DETERMINE WHICH ITEMS AND CONFIGURATIONS APPLY TO THE WORK
OF THIS PROJECT.
C THE MOUNTING HEIGHTS, CLEARANCES, AND CONFIGURATIONS SHOWN ON THIS SHEET
ARE TYPICAL AND SHALL APPLY TO ALL INSTANCES OF THE ITEM (OR GROUP OF ITEMS)
SHOWN UNLESS SPECIFICALLY NOTED OR DIMENSIONED OTHERWISE.
D SPECIAL OR NON-TYPICAL MOUNTING HEIGHTS OCCUR ONLY WHERE INDICATED BY
ANNOTATED SYMBOLS; BY KEY NOTES; BY NOTES ON PLANS, ELEVATIONS, OR DETAILS;
OR BY UNIQUE DIMENSIONS ON ELEVATIONS OR DETAILS.
E MOUNTING HEIGHTS, DIMENSIONS, CLEARANCES, AND ACCESS REQUIREMENTS FOR
TOILET ACCESSORIES SHOWN ON THIS SHEET ARE BASED UPON SPECIFIC
MANUFACTURERS AND MODELS AS INDICATED BY THE “EQUIPMENT SCHEDULE”. WHEN
SIMILAR ACCESSORIES OF OTHER SPECIFIED ACCEPTABLE MANUFACTURES (IF ANY)
ARE UTILIZED, MOUNTING HEIGHTS, CLEARANCES, AND ACCESS REQUIREMENTS OF THE
SIMILAR ACCESSORIES MAY VARY FROM THOSE SHOWN. WHEN SIMILAR ACCESSORIES
ARE UTILIZED, THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COORDINATION
REQUIRED TO ACHIEVE THE SAME AESTHETIC AND FUNCTIONAL DESIGN INTENT
ILLUSTRATED BY THAT SHOWN ON THE DRAWINGS.
F TACTILE EXIT SIGNS. A TACTILE EXIT SIGN STATING “EXIT” AND COMPLYING WITH ANSI
A117.1 SHALL BE PROVIDED ADJACENT TO EACH DOOR TO AN EGRESS STAIRWAY, AN
EXIT PASSAGEWAY AND EXIT DISCHARGE.
UP
TOOL
ROOM
RECEIVING
MANAGER'S
OFFICE
ADMIN./COPY/MAIL
100A
VEST.
CORRIDOR
TOILET
TOILET
LOCKERS
BREAK
ROOM/TRAINING
CAR
VAN
BUS/WASH
BAY
MECHANIC
WORK
ROOM
LOWER
LEVEL
PUMP
ROOM
DRIVER
WORKSTATION
WORK
BENCH
STAIR
ST-A
CORRIDOR
GROUNDS
MANAGER
GROUNDS
MAINTENANCE
GARAGE
EMERGENCY
GENERATOR
36" EXIT
36" EXIT
72" EXIT
S-1
S-1
S-1
S-1
S-1
S-1
S-1
S-1
54'
F1
F1
F1
F1
F1
I.T.
ELEC.
OPEN
OPEN
CORRIDOR
STAIR
ST-A
STORAGE
72" EXIT
F2
ABANDONED SPACE -
DOOR TO REMAIN LOCKED
FROM THE OUTSIDE,
PLUMBING TO REMAIN
OUT OF ORDER
ABANDONED SPACE -
DOOR TO REMAIN LOCKED
FROM THE OUTSIDE.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Management
Office of Construction and Facilities
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
1101 VETERANS DRIVE, LEXINGTON, KY
RENOVATE B-39 FOR
TRANSPORTATION & GROUNDS
596-19-102 JRA Architects 3225 Summit Square Place Lexington KY 40509 859-252-6781
G-103
LIFE SAFETY PLAN
11/16/2020 SW MD
CHAPTER 3
Use Group (Section 302): (B) Business – Training Area & Offices
(S-1) Storage - Motor Vehicle Repair Garage
CHAPTER 5
Basement (Section 502): Yes
Construction (New, Renovation, Addition): Renovation
Number of Buildings: 1
Type of Construction (NFPA 220): II-B
Actual Building Height (B): Stories: 2, Height: 45 feet
Allowable Height (B) (Table 504.3 & 4): Stories: 4, Height: 55 feet
Allowable Area per Floor (B) (Table 506.2): 23,000 SF
Mezzanines (Section 505) None
Area Modification for Frontage (Section 506.3): Not Required
Mixed Occupancy (Section 508):
Separated occupancies (508.3.3): No Separation Requirement (B/S-1), Table 508.4
Construction (Table 508.4): 0 HR
Incidental Use Areas (Table 509.1):
Boiler Rooms over 15psi/10hp N/A
CHAPTER 6
Fire Resistive Rating Requirements (Table 601, Type
II-B):
Primary Structural Frame: 0 HR
Exterior Bearing Walls: 0 HR
Interior Bearing Walls: 0 HR
Exterior Non-Bearing Walls per 602: 0 HR > 30 Feet
Interior Non-Bearing Walls: 0 HR
Floor Construction: 0 HR
Roof Construction: 0 HR
Combustible Materials allowed in Type II (Section 603): Yes, per Exceptions Listed
Gross Square Feet per Floor:
First Floor 5,258 GSF
Second Floor 558 GSF
Basement 450 GSF
Penthouse 450 GSF
Total Gross Square Footage: 6,716 GSF
CHAPTER 7
Fire Barriers (Section 707):
Openings thru fire-barriers (707.6): 25% aggregate length
Shaft Enclosure (713): 2 hour
Fire Door Ratings (Table 716.5):
Fire Barriers, 2 hour shaft and exit enclosures: 1 L hour
CHAPTER 10
Occupant Load per Floor (Table 1004.1.2):
First Floor (100 gross) 53
Second Floor (100 gross) 6
Basement (300 gross) 5
Penthouse (300 gross) 5
Total Building Occupant Load: 79
Egress Width per Occupant with Sprinkler (1005):
Stairs: 0.2" x 79 = Minimum 44" per Section 1011.2
Other: 0.15" x 79 = Minimum 44" per Section 1020.2
Spaces with One Means of Egress (Table 1006.2.1): Maximum 49 Occupants
Minimum Number of Exits for Occupant Load (Table 1006.3.1):
2 per story (1-500 occupants)
Accesible Means of Egress (Section 1009): 2 per 1006.3.1
Elevators Required (Section 1009.2.1): No
Area of Refuge (Section 1009.3 and 1009.4):
Exit Access Travel Distance (Table 1017.2): 300 feet with sprinkler system
Corridor Rating (Table 1020.1) 0 HR (w/ Sprinkler, > 30 Occupants)
Dead End Corridors (Section 1020.4): 50 Feet, with suppression for B, 20 for A-3
Exit Enclosure (1022.1): 2 hour
Vertical Exit Enclosures (Section 1023.2): 2 hour Fire Barrier (Section 707)
Exit Discharge (Section 1029): 50% through level, Exception 1
50% through level, Exception 1 None
CHAPTER 15
Penthouse (1510.2): > 30% roof area, = building story
Elevator Lobby (Section 3006): Not required, Exception 4
M2 VINYL WASH BAY CURTAIN
10 2800 - TOILET ACCESSORY
T1 GRAB BAR SET: 36" BACK, 42" SIDE, 18" VERTICAL C.F.C.I.
T2 FRAMED MIRROR - 18" x 30" C.F.C.I.
T3 TOILET PAPER DISPENSER - SINGLE ROLL O.F.C.I.
T4 PAPER TOWEL DISPENSER - SURFACE MOUNTED O.F.C.I.
T5 SOAP DISPENSER - SURFACE MOUNTED, VERTICAL O.F.C.I.
T6 STAINLESS STEEL UTILITY SHELF C.F.C.I.
10 4413 - FIRE EQUIPMENT
F1 SEMI-RECESSED FIRE EXTINGUISHER CABINET
F2 RECESSED FIRE EXTINGUISHER CABINET
22 0000 - PLUMBING FIXTURES
P1 WALL MOUNTED EMERGENCY EYEWASH STATION SEE PLUMBING
EQUIPMENT - NIC
R1 REFRIGERATOR O.F.O.I.
R2 MICROWAVE O.F.O.I.
0+
1+00 1+41
W W
W
W
W
W W W W W
EX. 1-1/4" GAS
SERVICE RISER W/
GAS REGULATOR
EX. 4" GAS SERVICE
RISER W/ GAS
REGULATOR
W
SS
SS
SS
SS
912.42
912.62 912.36
912.12
912.91
912.72
912.20 911.95
911.84
911.96
912.75
913.05
912.95
912.91
912.10
912.38
911.98
911.07
911.08
911.22
911.49
911.83
911.21
911.37
910.75
903.12
911.32
912.56
912.58
911.80
911.62
911.68
912.10
912.48
912.64
912.13
911.92 912.16
911.98
912.56
912.20
912.10
911.89
911.94
911.82
912.15
911.99
904.66
909.76
907.22
909.68
910.30
909.32
907.81
908.24
910.84
910.93
910.78
909.87
909.73
909.62
909.68
909.14 910.02
910.05
910.03
909.25
909.82 909.50
909.74 909.76
911.08911.12
911.82
911.86
911.80
910.43
907.72
907.57
910.72
911.02
911.67
907.52
906.94
908.89
909.04
908.72
906.30
910.46 911.68
910.51
908.70
910.95
908.96
909.11 910.20
911.25 911.81
910.71
910.51
909.23
48"
910.31
911.34 911.33
911.86 911.95
911.99 912.02
911.95
30"
18"
20"
20"
912.51
912.69
913.08
913.25
913.30
912.99
912.70 912.28
912.10 912.43
912.58 912.51
912.43
911.99 911.98
911.93
911.67
911.56
911.19
911.56 911.56
911.36911.26
910.51
911.95
912.20
912.86
913.06
913.09
911.98
911.98
912.92
913.29 913.46
913.06
912.17 912.17
912.46
913.51
913.57
30163
911.82
MH/UTILITY
30164
911.84
MH/UTILITY
30228
910.56
MH/30INUTILITY
30328
911.99
MH/UTILITY
30329
911.95
MH/UTILITY
30644
909.69
MH/UTILITY
30652
909.62
MH/UTILITY
30684
909.73
MH/UTILITY
30685
909.67
MH/UTILITY
30714
911.82
MH/UTILITY
30715
911.85
MH/UTILITY
30716
910.08
MH/UTILITY
30552
904.601
DRAIN/FULLOFDEBRI
30566
907.166
DRAIN/FULLOFDEBRI
30133
957.26
N/BLDHEIGHT
30518
927.39
N/BLDHEIGHT
30519
956.89
N/BLDHEIGHT
2 STORY BRICK
BUILDING 39
WITH BASEMENT
6" C
O N
C C
U R
B
6" CONC CURB
8" C
O N
C C
U R
B
FFE-911.94
FFE-903.59
FFE-912.59
FFE-919.66
FFE-905.01
FFE-912.64
FFE-912.05
FFE-915.11
FFE-915.11
FFE-912.64
FFE-911.80
G
AT
E
D
IE
SE
L
TA
N
K
#11
BUILDING HEIGHT:45.9'
BUILDING HEIGHT:17'
3" PVC
AS
PH
AL
T
ASPHALT
CONCRETE
C O
N C
R
ET
E
CONCRETE
CONCRETE
CONCRETE
CONCRETE
CONCRETE
CONCRETE
GRASS
GRASS
GRASS
ST
O
N E
914.01
912.59
913.47
913.64 913.64
913.87
911.04
913.30
912.60
912.08 912.05
912.78
914.48
915.86
915.42
915.30 915.48
914.85
912.42
913.72
913.80
913.74
913.72
913.18
911.75
912.56
912.69
912.74
912.19911.48
913.78
913.82
912.53
912.31 911.64911.16
911.10
910.81 910.81
911.67
911.37
911.13
911.31 911.70
912.26
912.72
913.30
913.56
912.76
912.79
915.76
912.90 912.88
916.59
916.16 915.92
915.84 915.80
915.79
911.66
912.06
912.05
912.41
912.49
912.58
1 STORY BRICK
1 STORY BLOCK
FFE-914.94
FFE-913.95
FFE-914.03
FFE-914.06
FFE-913.99
FFE-914.06
ASPHALT
CONC
CONC
C O
N C
GRASS
GRASS
GRATE
CL 5' BAY
EOI
EOI
EOI
CO
M
CO
M
W-D
W-D
W-D
W-D
W-D W-D W-D W-D W-D W-D W-D W-D
CONC
PAD FOR
DISPENSER
8" vcp
6" ci
6" v cp
12" vcp
4" c i
6" vcp
6" v cp
" v cp
" v cp
6" ci
4" pvc8" vcp
8" vcpinv(ne):900.95 direction only direction only direction only direction only direction only st m st m st m
W-D
W -D
W -D
W -D
W -D
W -D
W -D
C O
M C
O M
C O
M
C O
M C
O M
C O
M C
O M
C O
M C
O M
C O
M C
O M
C O
M
C O
M C
O M
C O
M C
O M
C O
M C
O M
C O
M C
O M
C O
M C
O M
C O
M
UGT UGT
unk unk unk unk unk un k un k un k un k un k un k un k
GAS CUT
6' BAY
8' BAY
METAL
STAIRS
9' GARAGE BAY
METAL
STAIRS
8' CHAIN LINK FENCEWITH BARBED WIRE
un k un k
UGTUGT
UG
T
UGT
U G
T U
G T
U G
T U
G T
U G
T U
G T
U G
T U
G T
U G
T
(4) 3" DOUBLE
WALL FUEL LINES
(FIELD VERIFY
LOCATION)
NATURAL GAS
GENERATOR
(4) 3" DOUBLE
WALL FUEL LINES
(FIELD VERIFY
LOCATION)
D
IE
SE
L
TA
N
K
D
IE
SE
L
TA
N
K
D
IE
SE
L
TA
N
K exist drainage inlet tr:911.32 inv(nw):908.86 exist clean out tr:911.49 inv(se):908.79 exist sanitary mh tr:913.20inv(ne):903.55 inv(se):903.50 inv(w):904.10 direction only exist sanitary mh tr:912.73 inv(ne):903.58inv(sw):903.55 inv(se):911.23 inv(nw):904.49 direction only exist sanitary mh tr:910.96 inv(ne):904.09inv(sw):904.09 inv(se):904.36 inv(se):906.86 drop pipe exist drainage mh tr:909.90 inv(ne):900.28 inv(nw):899.15 inv(ne):905.54 inv(e):900.82 inv(sw):902.50 inv(sw):899.80
BUILDING HEIGHT:46.6'1 STORY BRICK
BUILDING 41
INCENERATOR BLDG.
A
A
B
C C
C
C
D
D
E
FOR E85
DEMOLITION
WORK 150'
SOUTH
SEE SHEET
CU-003
1A
1B
1C
1C
1D
1D
R15
9'
(ABANDONED TO BE
REMOVED SEE INFORMATION
ON PLUMBING DRAWINGS)
DIESEL FUEL LOADING STATION,
BOLLARDS & TERMINATION WELLSC
DIESEL FUEL
TERMINATION WELLS
C
DIESEL FUEL
TERMINATION WELLS
C
DIESEL FUEL
TERMINATION WELLS
C
DIESEL FUEL
TERMINATION
WELLSC
SLOPE PAVEMENT
DOWN TO
EXISTING DRIVE
11A
11B12
11B
11B
11B
11A
11A
11A
13A
13B
A. REMOVE EXISTING CONC. CURB FOR NEW DRIVE APPROACH.
B. REMOVE EXISTING CONCRETE PAVEMENT
C. PURGE EXISTING FUEL LINES AND REMOVE ALL BELOW GRADE DOUBLE WALL
PIPING AND LEAK PROTECTION WELLS ON EACH END OF UNDERGROUND
PIPING. FIELD VERIFY LOCATION. ABOVE GRADE PIPE CONNECTED TO
BELOW GRADE PIPING SHALL BE REMOVED AND CAPPED AT TO THE FIRST
ABOVE GROUND FITTING AT THE TANK END AND TO THE BUILDING WALL AT
BUILDING END. THIS FUEL LINE DEMOLITION WORK SHALL INCLUDE ALL
BACKFILLING, RESTORATION AND SEEDING OF DISTURBED AREAS AND SHALL
BE PART OF THE BASE BID. IF ALTERNATE #2 IS NOT ACCEPTED, CUT AND
CAP PIPES REMAINING AT FUEL STORAGE TANKS.
D. ADD ALTERNATE # 2 - REMOVE EXISTING DIESEL FUEL TANKS AND ABOVE
GROUND PIPING, PERIMETER FENCE , STONE GROUND COVERING AND
CONCRETE FOUNDATIONS AND SLABS. THIS ALTERNATE WORK SHALL ALSO
INCLUDE ALL RESTORATION, TOP SOIL, FINISH GRADING AND SEEDING OF
AREAS DISTURBED. VERIFY TANKS ARE EMPTY PRIOR TO REMOVAL. NOTIFY
COR IF TANKS ARE NOT EMPTY.
E. ADD ALTERNATE #1 - REMOVE EXISTING E85 TANK AND EQUIPMENT TO
INCLUDE THE FOLLOWING:
xx TANK, SENSORS, CONTROLLERS AND FOUNDATION SLAB xx TANK FILL STATION , PUMP, PIPING, PIPE SUPPORT FOUNDATIONS xx DISTRIBUTION PUMP CONTROLS AND ACCESSORIES xx SOLAR PANELS, BATTERY PANEL, WIRING AND ACCESSORIES xx CANOPY AND FOUNDATIONS.
xx SECURITY CAMERA, LIGHT, POLE AND FOUNDATIONS. PULL
CONDUCTORS BACK TO SOURCE PANEL.
THIS WORK SHALL ALSO INCLUDE ALL RESTORATION, TOP SOIL, FINISH
GRADING AND SEEDING OF AREAS DISTURBED. THIS WORK IS SHOWN ON
SHEET
1. NEW CONCRETE APPROACH SLAB - SEE DETAILS ON SHEET CU-002
A. EXPANSION JOINT PER KTC 807.04.03 AT BUILDING WALL.
B. SAW CUT CONTROL JOINT.
C. REINFORCE IRREGULAR SHAPED DRIVE AREAS W/#3 BARS AT 12" EACH
WAY.
D. SAWCUT EDGE OF ASPHALT AT EDGE OF CONCRETE. PROVIDE JOINT
SEALANT PER KTC 807.03.01 BETWEEN CONCRETE AND ASPHALT
PAVEMENT.
E. TOP OF CONCRETE SHALL MATCH NEW TOP OF BUILDING SLAB
ELEVATION WHICH WILL BE 2" ABOVE EXISTING SLAB. SEE ARCH &
STRUCTURAL PLANS.
2. NEW 6" FIRE MAIN (SEE PROFILE ON SHEET CU-002).
3. NEW 6" GATE VALVE AND POST INDICATOR.
4. CONNECT TO EXISTING 8" FIRE MAIN WITH TAPPING TEE AND VALVE.
5. 6" 45° ELBOW W/ BLOCKING OR JOINT RESTRAINTS.
6. 6" 90° ELBOW W/ BLOCKING OR JOINT RESTRAINTS.
7. NEW 6" FIRE MAIN BUILDING SERVICE ENTRY - CORE BUILDING WALL OR
REUSED ABANDONED STEAMLINE PENETRATION AND TERMINATE END OF
PIPE WITH BLIND FLANGE OR GROOVED JOINT CAP FOR PRESSURE
TESTING. COORDINATE LOCATION WITH BUILDING FIRE PROTECTION PIPING
WORK. RESTRAIN END CAP WITH (2) 3
4" STAINLESS STEEL THREADED RODS
ANCHORED TO BUILDING WALL WITH ADHESIVE (5" MIN EMBEDMENT).
8. NEW GARAGE DOOR (SEE ARCH PLANS).
9. NEW 6" INTEGRAL CONCRETE CURB WITH NEW CONCRETE DRIVE. TAPER
CURB FROM 0' AT BUILDING TO 6" AT STREET.
10. NEW 6" PIPE BOLLARD ADJACENT TO OVERHEAD DOORS. SEE BOLLARD
DETAIL ON SHEET CU-002.
11. PROVIDE EROSION CONTROL PRACTICES AROUND CONSTRUCTION SITE.
SEE SPECIFIC EROSION CONTROL AND OTHER ENVIRONMENTAL NOTES ON
SHEET C-003.
A. SILT WORM GEOTEXTILE TUBE ALONG EDGE OF PAVEMENT AND
NEAREST CATCH BASIN DRAINING THE SITE PER DETAIL ON SHEET CZ P
CU-002.
B. PROVIDE SLIT FENCE ALONG LOW SIDE OF DISTURBED AREAS PER
DETAIL ON SHEET CZ P CU-002.
12. PROVIDE TEMPORARY 8' HIGH CHAIN FENCE (NO BARBED WIRE)…