Pricing_Proposal-24-1061(reference_only).pdf

PDF 321 KB Posted

Attached to
Annual Water and Reclaimed Water Repairs and Extensions for Fiscal Years 2024 - 2026
Solicitation number
24-1061-ITB-C
Issued by
Pinellas County, Clewiston City, Florida

About this file

This Pricing Proposal is for the Invitation to Bid - Construction (ITB-C) #24-1061-ITB-C, issued by a Florida county government for Annual Water and Reclaimed Water Repairs and Extensions for Fiscal Years 2024-2026. The contract covers comprehensive water infrastructure repair and installation services, including pipeline installations, point repairs, and restoration work across six distinct groups: Mobilization, Pipeline Installation, Pipeline Point Repairs & Offsets, Restoration, Maintenance of Traffic, and Unspecified Work. The project involves various tasks such as directional boring, pipe installations in multiple diameters (2" to 24"), excavation, disinfection, service connections, and roadway restoration, with specific quantities ranging from 2 to 4,300 linear feet or units for different line items.

The pricing proposal is structured as a unit price contract with detailed line items across multiple categories, allowing flexible work order-based project execution. The contract includes provisions for routine and emergency mobilization, different pipe material types (PVC, HDPE, Ductile Iron), various excavation depths, traffic management, and restoration services. A notable feature is the "Unspecified Work" group with a placeholder of 1,100,000 units at $1.00 per unit, which provides flexibility for unforeseen project requirements. The comprehensive nature of the pricing schedule suggests the county anticipates multiple small to medium-sized water infrastructure repair and extension projects over the fiscal years 2024-2026, with the intent to efficiently manage infrastructure maintenance through a flexible, pre-priced contract mechanism.

View the file

Other files

Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Invitation to Bid - Construction (ITB-C) #24-1061-ITB-C Title: Annual Water and Reclaimed Water Repairs and Extensions for Fiscal Years 2024 - 2026

9. Pricing Proposal

GROUP A - MOBILIZATION

Pay Item No. Description Quantity Unit Unit Price Amount

101-0100-

MOBILIZATION FOR ROUTINE

RESPONSE

20 EA

101-0100-

MOBILIZATION FOR EMERGENCY

RESPONSE

8 EA

TOTAL

GROUP B - PIPELINE INSTALLATION

Pay Item No. Description Quantity Unit Unit Price Amount

120-0020 EXCAVATION, UNSUITABLE MATERIAL 200 CY

121-1000 FLOWABLE CONCRETE FILL 200 CY

125-3001 SELECT BEDDING AND BACKFILL

MATERIAL - GRAVEL

100 CY

PW-330521-

202-

02P17RJF

DIRECTIONAL BORE 2" RESTRAINED

JOINT PVC SDR-17 INCLUDING

FITTINGS

100 LF

PW-330521-

202-02PE9

DIRECTIONAL BORE 2" HDPE DR-9 4,300 LF

PW-330521-

202-04FP18

DIRECTIONAL BORE 4" FUSIBLE OR

RESTR. JT. C900 PVC PIPE DR18

100 LF

PW-330521-

202-04PE11

DIRECTIONAL BORE 4" HDPE DR-11 200 LF

PW-330521-

202-06FP18

DIRECTIONAL BORE 6" FUSIBLE OR

RESTR. JT. C900 PVC PIPE DR 18

200 LF

PW-330521-

202-06PE11

DIRCTIONAL BORE 6" HDPE DR-11 200 LF

PW-330521-

202-08FP18

DIRECTIONAL BORE 8" FUSIBLE OR

RESTR. JT. C900 PVC PIPE DR18

500 LF

PW-330521-

202-08PE11

DIRECTIONAL BORE 8" HDPE DR-11 1,000 LF

PW-330521-

202-10PE11

DIRECTIONAL BORE 10" HDPE DR-11 100 LF

PW-330522-

202-12FP18

DIRECTIONAL BORE 12" FUSIBLE OR

RESTR. JT. C900 PVC PIPE DR18

500 LF

PW-330522-

202-12PE11

DIRECTIONAL BORE 12" HDPE DR-11 300 LF

PW-330522-

202-14PE11

DIRECTIONAL BORE 14" HDPE DR-11 100 LF

PW-331101-

105-9001

OUT OF SERVICE MAIN GROUTING 25 CY

PW-331101-

105-90204

DISCONNECT AND PLUG 2" OR 4"

W.M./RCW

4 EA

PW-331101-

105-90406

DISCONNECT AND PLUG 6" OR 8"

W.M./RCW

4 EA

PW-331101-

105-91012

DISCONNECT AND PLUG 10" OR 12"

W.M./RCW

3 EA

PW-331101-

304-

02P17RJF

2" PVC RESTRAINED PIPE SDR 17

INCLUDING FITTINGS

100 LF

PW-331101-

304-02P21

2" PVC PIPE SDR-21 INCLUDING

FITTINGS

100 LF

PW-331101-

304-04D

4" D.I. PIPE CLASS 350 20 LF

PW-331101-

304-04DRJF

4" D.I. RESTRAINED PIPE CLASS 350 20 LF

PW-331101-

304-04P18

4" PVC PIPE C900 DR 18 100 LF

PW-331101-

304-

04P18RJF

4" PVC RESTRAINED PIPE C900 DR 18 50 LF

PW-331101-

304-04PE11

4" HDPE DR 11, DIPS OD 50 LF

PW-331101-

304-06D

6" D.I. PIPE CLASS 350 200 LF

PW-331101-

304-06DRJF

6" D.I. RESTRAINED PIPE CLASS 350 300 LF

PW-331101-

304-06918

6" PVC PIPE C900 DR 18 2,000 LF

PW-331101-

304-

06P18RJF

6" PVC RESTRAINED PIPE C900 DR 18 1,000 LF

PW-331101-

304-06PE11

6" HDPE DR 11, DIPS OD 100 LF

PW-331101-

304-08D

8" D.I. PIPE CLASS 350 300 LF

PW-331101-

304-08DRJF

8" D.I. RESTRAINED PIPE CLASS 350 1,700 LF

PW-331101-

304-08P18

8" PVC PIPE C900 DR 18 1,000 LF

PW-331101-

304-

08P18RJF

8" PVC RESTRAINED PIPE C900 DR 18 300 LF

PW-331101-

304-08PE11

8" HDPE DR 11, DIPS OD 100 LF

PW-331101-

304-10D

10" D.I. PIPE CLASS 350 50 LF

PW-331101-

304-10DRJF

10" D.I. RESTRAINED PIPE CLASS 350 50 LF

304-10P18

10" PVC PIPE C900 DR 18 200 LF

PW-331101-

304-

10P18RJF

10" PVC RESTRAINED PIPE C900 DR 18 200 LF

PW-331101-

304-10PE11

10" HDPE DR 11, DIPS OD 50 LF

PW-331101-

304-12D

12" D.I. PIPE CLASS 350 200 LF

PW-331101-

304-12DRJF

12" D.I. RESTRAINED PIPE CLASS 350 100 LF

PW-331101-

304-12P18

12" PVC PIPE C900 DR 18 200 LF

PW-331101-

304-

12P18RJF

12" PVC RESTRAINED PIPE C900 DR 18 2,000 LF

PW-331101-

304-12PE11

12" HDPE DR 11, DIPS OD 100 LF

PW-331101-

304-14PE11

14" HDPE DR 11, DIPS OD 50 LF

PW-331101-

304-02RJ

2" RESTRAINED JOINT 20 EA

PW-331101-

304-04RJ

4" RESTRAINED JOINT 40 EA

PW-331101-

304-06RJ

6" RESTRAINED JOINT 316 EA

PW-331101-

304-08RJ

8" RESTRAINED JOINT 208 EA

PW-331101-

304-10RJ

10" RESTRAINED JOINT 10 EA

304-12RJ

12" RESTRAINED JOINT 80 EA

PW-331101-

304-90204

2" - 4" PIPE & APPURTENANCES OVER

DEPTH EXCAVATION

200 LF

PW-331101-

304-90608

6" - 8" PIPE & APPURTENANCES OVER

DEPTH EXCAVATION

500 LF

PW-331101-

304-91012

10" - 12" PIPE & APPURTENANCES

OVER DEPTH EXCAVATION

200 LF

PW-331101-

305-90204

REMOVE OUT OF SERVICE PIPE 2" OR

4"

400 LF

PW-331101-

305-90608

REMOVE OUT OF SERVICE PIPE 6" OR

8"

600 LF

PW-331101-

305-91012

REMOVE OUT OF SERVICE PIPE 10" OR

12"

600 LF

PW-331101-

308-02SC

2" SLEEVED CONNECTION 6 EA

PW-331101-

308-04SC

4" SLEEVED CONNECTION 15 EA

PW-331101-

308-06SC

6" SLEEVED CONNECTION 20 EA

PW-331101-

308-08SC

8" SLEEVED CONNECTION 30 EA

PW-331101-

308-10SC

10" SLEEVED CONNECTION 10 EA

PW-331101-

308-12SC

12" SLEEVED CONNECTION 10 EA

PW-331101-

308-

90204RD

REVERSE DEADMAN FOR 2" TO 4"

PIPE

12 EA

308-

90608RD

REVERSE DEADMAN FOR 6" TO 8"

PIPE

10 EA

PW-331101-

308-

91012RD

REVERSE DEADMAN FOR 10" TO 12"

PIPE

12 EA

PW-331101-

308-C153

DUCTILE IRON PIPE FITTINGS 12 TN

PW-331101-

309-02RW

2" RESIL. WEDGE GATE VALVE AND

BOX

18 EA

PW-331101-

309-

04RW515

4" RESIL. WEDGE GATE VALVE AND

BOX

6 EA

PW-331101-

309-

06RW515

6" RESIL. WEDGE GATE VALVE AND

BOX

13 EA

PW-331101-

309-

08RW515

8" RESIL. WEDGE GATE VALVE AND

BOX

13 EA

PW-331101-

309-

10RW515

10" RESIL. WEDGE GATE VALVE AND

BOX

5 EA

PW-331101-

309-

12RW515

12" RESIL. WEDGE GATE VALVE AND

BOX

6 EA

PW-331101-

310-0002

FIRE HYDRANT ASSEMBLY WITH

VALVE (5-1/4")

19 EA

PW-331101-

310-0003

FIRE HYDRANT ASSEMBLY WITHOUT

VALVE (5-1/4")

8 EA

PW-331101-

310-9001

RELOCATE FIRE HYDRANT 5 EA

PW-331101-

312-0402TV

4" X 2" TAPPING SADDLE, VALVE AND

BOX

2 EA

312-0404TV

4" X 4" TAPPING SLEEVE, VALVE AND

BOX

2 EA

PW-331101-

312-0602TV

6" X 2" TAPPING SADDLE, VALVE AND

BOX

8 EA

PW-331101-

312-0604TV

6" X 4" TAPPING SLEEVE, VALVE AND

BOX

2 EA

PW-331101-

312-0606TV

6" X 6" TAPPING SLEEVE, VALVE AND

BOX

4 EA

PW-331101-

312-0802TV

8" X 2" TAPPING SADDLE, VALVE AND

BOX

4 EA

PW-331101-

312-0804TV

8" X 4" TAPPING SLEEVE, VALVE AND

BOX

2 EA

PW-331101-

312-0806TV

8" X 6" TAPPING SLEEVE, VALVE AND

BOX

4 EA

PW-331101-

312-0808TV

8" X 8" TAPPING SLEEVE, VALVE AND

BOX

2 EA

PW-331101-

312-1006TV

10" X 6" TAPPING SLEEVE, VALVE AND

BOX

3 EA

PW-331101-

312-1008TV

10" X 8" TAPPING SLEEVE, VALVE AND

BOX

1 EA

PW-331101-

312-1010TV

10" X 10" TAPPING SLEEVE, VALVE

AND BOX

1 EA

PW-331101-

312-1206TV

12" X 6" TAPPING SLEEVE, VALVE AND

BOX

6 EA

PW-331101-

312-1208TV

12" X 8" TAPPING SLEEVE, VALVE AND

BOX

10 EA

PW-331101-

314-01LS

1" SERVICE CONNECTION 41 EA

PW-331101-

314-01SS

1" SERVICE CONNECTION (SHORT

SIDE)

40 EA

314-02LS

2" SERVICE CONNECTION 20 EA

PW-331101-

314-02SS

2" SERVICE CONNECTION (SHORT

SIDE)

20 EA

PW-331101-

314-15LS

1-1/2" SERVICE CONNECTION 20 EA

PW-331101-

314-15SS

1 1/2" SERVICE CONNECTION (SHORT

SIDE)

10 EA

PW-331101-

314-75LS

3/4" SERVICE CONNECTION 69 EA

PW-331101-

314-75SS

3/4" SERVICE CONNECTION (SHORT

SIDE)

32 EA

PW-331101-

314-01ST

1" HDPE DR 9, CTS OD (SERVICE LINE

TUBING)

500 LF

PW-331101-

314-02ST

2" HDPE DR 9, CTS OD (SERVICE LINE

TUBING)

500 LF

PW-331101-

314-15ST

1-1/2" HDPE DR 9, CTS OD (SERVICE

LINE TUBING)

1,000 LF

PW-331101-

314-75ST

3/4" HDPE DR 9, CTS OD (SERVICE

LINE TUBING)

500 LF

PW-331101-

314-901MBR

1" METER AND BACKFLOW (REMOVE,

RELOCATE & RECONNECT)

10 EA

PW-331101-

314-902MBR

2" METER AND BACKFLOW (REMOVE,

RELOCATE & RECONNECT)

10 EA

PW-331101-

314-915MBR

1-1/2" METER AND BACKFLOW

(REMOVE, RELOCATE & RECONNECT)

10 EA

PW-331101-

314-975MBR

3/4" METER AND BACKFLOW

(REMOVE, RELOCATE & RECONNECT)

21 EA

PW-331101-

316-0001

BOLLARD (FIRE HYDRANT GUARD) 8 EA

PW-331301-

000-0206

DISINFECTION OF 2" TO 6" WATER

MAIN

15,700 LF

PW-331301-

000-0812

DISINFECTION OF 8" TO 12" WATER

MAIN

17,600 LF

PW-331301-

000-1420

DISINFECTION OF 14" TO 20" WATER

MAIN

500 LF

PW-331101-

309-01AROS

1" AIR RELEASE ASSEMBLY (OFFSET) 4 EA

PW-331101-

309-02AROS

2" AIR RELEASE ASSEMBLY (OFFSET) 4 EA

PW-331301-

301-0002

2" BLOW-OFF ASSEMBLY PERMANENT 5 EA

PW-331301-

301-004A

4" BLOW-OFF ASSEMBLY,

PERMANENT

1 EA

005-0900 AS-BUILT SURVEY 10 EA

GROUP C - PIPELINE POINT REPAIRS & OFFSETS

PW-331101-

500-0002

2" DIAMETER POINT REPAIR 2 EA

PW-331101-

500-0004

4" DIAMETER POINT REPAIR 2 EA

PW-331101-

500-0006

6" DIAMETER POINT REPAIR 4 EA

PW-331101-

500-0008

8" DIAMETER POINT REPAIR 4 EA

PW-331101-

500-0010

10" DIAMETER POINT REPAIR 1 EA

500-0012

12" DIAMETER POINT REPAIR 1 EA

PW-331101-

500-0016

16" DIAMETER POINT REPAIR 1 EA

PW-331101-

500-0020

20" DIAMETER POINT REPAIR 1 EA

PW-331101-

500-0024

24" DIAMETER POINT REPAIR 1 EA

PW-331101-

501-0002

2" DIAMETER PIPELINE RELOCATION

OFFSET

3 EA

PW-331101-

501-0004

4" DIAMETER PIPELINE RELOCATION

OFFSET

2 EA

PW-331101-

501-0006

6" DIAMETER PIPELINE RELOCATION

OFFSET

3 EA

PW-331101-

501-0008

8" DIAMETER PIPELINE RELOCATION

OFFSET

2 EA

PW-331101-

501-0010

10" DIAMETER PIPELINE RELOCATION

OFFSET

1 EA

PW-331101-

501-0012

12" DIAMETER PIPELINE RELOCATION

OFFSET

1 EA

PW-331101-

501-0016

16" DIAMETER PIPELINE RELOCATION

OFFSET

1 EA

PW-331101-

601-0006

INITIAL EXCAVATION, 0' - 6' DEPTH 8 EA

PW-331101-

601-0608

INITIAL EXCAVATION, 6' - 8' DEPTH 6 EA

PW-331101-

601-0810

INITIAL EXCAVATION, 8' - 10' DEPTH 4 EA

PW-331101-

601-1012

INITIAL EXCAVATION, 10' - 12' DEPTH 4 EA

601-1214

INITIAL EXCAVATION, 12' - 14' DEPTH 2 EA

PW-331101-

601-1416

INITIAL EXCAVATION, 14' - 16' DEPTH 2 EA

PW-331101-

602-0006

ADDITIONAL EXCAVATION, 0' - 6'

DEPTH

100 LF

PW-331101-

602-0608

ADDITIONAL EXCAVATION, 6' - 8'

DEPTH

100 LF

PW-331101-

602-0810

ADDITIONAL EXCAVATION, 8' - 10'

DEPTH

50 LF

PW-331101-

602-1012

ADDITIONAL EXCAVATION, 10' - 12'

DEPTH

50 LF

PW-331101-

602-1214

ADDITIONAL EXCAVATION, 12' - 14'

DEPTH

30 LF

PW-331101-

602-1416

ADDITIONAL EXCAVATION, 14' - 16'

DEPTH

10 LF

PW-331101-

650-0608

WELL POINT DEWATERING, INITIAL, 6'

- 8' DEPTH

12 EA

PW-331101-

650-0810

WELL POINT DEWATERING, INITIAL, 8'

- 10' DEPTH

4 EA

PW-331101-

650-1012

WELL POINT DEWATERING, INITIAL,

10' - 12' DEPTH

2 EA

PW-331101-

650-1214

WELL POINT DEWATERING, INITIAL,

12' - 14' DEPTH

2 EA

PW-331101-

650-1416

WELL POINT DEWATERING, INITIAL,

14' - 16' DEPTH

2 EA

PW-331101-

650-1699

WELL POINT DEWATERING, INITIAL, >

16' DEPTH

2 EA

PW-331101-

651-0608

WELL POINT DEWATERING,

ADDITIONAL, 6' - 8' DEPTH

10 EA

651-0810

WELL POINT DEWATERING,

ADDITIONAL, 8' - 10' DEPTH

10 EA

PW-331101-

651-1012

WELL POINT DEWATERING,

ADDITIONAL, 10' - 12' DEPTH

10 EA

PW-331101-

651-1214

WELL POINT DEWATERING,

ADDITIONAL, 12' - 14' DEPTH

5 EA

PW-331101-

651-1416

WELL POINT DEWATERING,

ADDITIONAL, 14' - 16'

5 EA

PW-331101-

651-1699

WELL POINT DEWATERING,

ADDITIONAL, > 16' DEPTH

5 EA

GROUP D - RESTORATION

200-1000 ROADWAY BASE, LIME ROCK, PRIMED,

MIN. LBR 100, VARIABLE THICKNESS

15 CY

204-1000 ROADWAY BASE, CRUSHED

CONCRETE/GRADED AGGREGATE,

MIN. LBR 100, VARIABLE

15 CY

234-1250-

SUPERPAVE ASPHALT BASE, TYPE B

12.5, VARIABLE THICKNESS

10 TN

334-3095-

SUPERPAVE ASPHALT CONCRETE,

TYPE SP 9.5, FINE, TRAFFIC LEVEL C,

VARIABLE THICKNESS

2 TN

334-3125-

SUPERPAVE ASPHALT CONCRETE,

TYPE SP 12.5, FINE, TRAFFIC LEVEL C,

VARIABLE THICKNESS

10 TN

350-0206 PAVEMENT, CEMENT CONCRETE, 6"

MIN. THICKNESS (DRIVEWAYS)

50 SY

350-0208 PAVEMENT, CEMENT CONCRETE, 8"

THICK

50 SY

353-0100 DRIVEWAY RESTORATION, IN KIND 30 SY

353-0102 DRIVEWAY RESTORATION, IN KIND,

DECORATIVE BLOCK

10 SY

380-1050 MILLING EXISTING ASPHALT

PAVEMENT, 1/2" AVERAGE DEPTH

100 SY

380-1075 MILLING EXISTING ASPHALT

PAVEMENT, 3/4" AVERAGE DEPTH

100 SY

380-1100 MILLING EXISTING ASPHALT

PAVEMENT, 1" AVERAGE DEPTH

200 SY

520-2000-

CURB & GUTTER, CONCRETE, FDOT

TYPE A

60 LF

520-1000-

CURB & GUTTER, CONCRETE, FDOT

TYPE E

60 LF

520-1000-

CURB & GUTTER, CONCRETE, FDOT

TYPE F

60 LF

520-1315-

VALLEY GUTTER, CONCRETE, PCED

INDEX 1315

60 LF

522-1004 SIDEWALK, CONCRETE, 4" MIN.

THICKNESS, REMOVE AND REPLACE

100 SF

522-1006 SIDEWALK, CONCRETE, 6" MIN.

THICKNESS, REMOVE AND REPLACE

100 SF

575-0108 SODDING, IN-KIND 50,000 SF

GROUP E - MAINTENANCE OF TRAFFIC

102-1000-

FLAGMEN (PER FLAGMAN) 170 HR

102-104 TEMPORARY SIGNALIZATION AND

MAINTENANCE, INTERSECTION

90 EA/DY

102-107-1 TEMPORARY TRAFFIC DETECTION

AND MAINTENANCE, INTERSECTION

60 EA/DY

102-1000-

MULTI LANE (FDOT INDEX NO. 613) 4 EA/DAY

102-1000-

MULTI LANE (FDOT INDEX NO. 614) 4 EA/DAY

102-1000-

MULTI LANE (FDOT INDEX NO. 615) 4 EA/DAY

102-1000-

MULTI LANE (FDOT INDEX NO. 616) 4 EA/DAY

102-1000-

MULTI LANE (FDOT INDEX NO. 617) 4 EA/DAY

102-1076 ARROW BOARD - 5' MINIMUM

HORIZONTAL SIZE

30 EA/DAY

102-1099 VARIABLE MESSAGE BOARD 20 EA/DAY

102-1301 LOW PROFILE BARRIER (FDOT INDEX

NO. 412)

50 EA/DAY

102-1600 SIGN IN WORK ZONE 500 EA/DAY

711-11-121 6" SOLID LINE THERMO PLASTIC,

PERMANENT

50 LF

711-11-125 24" STOP BAR, SOLID, THERMO

PLASTIC, PERMANENT

50 LF

711-11-141 6" SKIP LINE (6' - 10' SKIP) THERMO

PLASTIC, PERMANENT

50 LF

800-9001 BARRICADE, TYPE III WITH WARNING

LIGHT

200 EA/DAY

800-9002 BARRICADE, TYPE I OR II WITH

WARNING LIGHT

500 EA/DAY

GROUP F - UNSPECIFIED WORK

9999-1000 GROUP F-UNSPECIFIED WORK 1,100,000 EA $1.00

File details come from the government source that posted it. Updated .