Power-Sonic_Lead-Acid_SDS-Report-70_405_23_0485_01.pdf

PDF 351 KB Posted

Attached to
Hazardous materials/waste pickup and disposal Federal contract opportunity
Solicitation number
1333MF25Q0044
Issued by
Department of Commerce National Oceanic and Atmospheric Administration

About this file

This Safety Data Sheet (SDS) provides detailed information about a Rechargeable Sealed Lead Acid Battery manufactured by Power-Sonic Corporation. The document is dated February 24, 2023, and covers battery models in the PS/PHR/PDC/PG/PSH/PG2V/PGFT/PSS/AGM-FA Series, intended for industrial and general purpose power supply applications. The battery contains key components including lead (33-35%), sulfuric acid (16-23%), and other materials like glass fiber separators and trace amounts of tin and calcium.

The SDS outlines critical safety, handling, and regulatory information, noting that while the battery is not classified as hazardous, it contains substances with potential health risks. Specifically, lead is listed as probably carcinogenic, and sulfuric acid is classified as carcinogenic to humans. The document provides comprehensive guidance on transportation (UN2800 classification), disposal methods, and protective measures, emphasizing the importance of avoiding short-circuiting, excessive heat, and direct sunlight. The battery is regulated under multiple international chemical inventories and subject to various U.S. federal and state regulations, including California Proposition 65.

View the file

Other files for this federal contract opportunity

Other files attached to Hazardous materials/waste pickup and disposal, newest first.
File Type Posted
Sol_1333MF25Q0044_Amd_0001.pdf PDF
Solicitation_1333MF25Q044_0001__Q_A_0001.docx DOCX document
La_Jolla_Building_Map_0001.pdf PDF
1000014895.jpg JPG image
Sol_1333MF25Q0044.pdf PDF
1000014897.jpg JPG image
1000014890.jpg JPG image
1000014893.jpg JPG image
Appendix_A_Option_CLIN__Estimate_Unit_Pricing.xlsx XLSX spreadsheet
WD_2015-5636_Rev_27_6_2_2025.pdf PDF
Safety_Data_Sheets.pdf PDF
1000014892.jpg JPG image
Hazmat_Removal_La_Jolla_SOW_July_2025.docx DOCX document
1000014891.jpg JPG image
1000014894.jpg JPG image
1000014896.jpg JPG image
Show all 16

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SAFETY DATA SHEET REPORT

SDS Number: 70.405.23.0485.01 Dated 2023-02-24

PRODUCT AND COMPANY IDENTIFICATION

Product Name: Rechargeable Sealed Lead Acid Battery/Valve Regulated Lead Acid

Battery/AGM

Company: Power-Sonic Corporation

Address: 365 Cabela Dr. Suite 300 Reno, NV 89503

Telephone: 775-824-6500

Email: puneet.kalia@power-sonic.com

Fax: N/A

Emergency Phone: 1-800-222-1222

Recommend use of the chemical and restrictions on use:

Industrial and General Purpose battery. Power supply

SDS Number: 70.405.23.0485.01

Effective Date: 2023-02-24

Service Requested: Safety Data Sheet for the Product

Summary: The contents and format of this SDS are in accordance with Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations (According to HCS-2012 APPENDIX D TO §1910.1200)

Note: This SDS is compiled based on the information such as ingredients provided by the applicant and our current knowledge. This SDS shall be used only as a guide. The users of this SDS must make independent judgments on the correctness and completeness and then decide its suitability according to the actual situation. The users should take the relevant legal responsibilities for the consequences of use.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shanghai Branch Testing Center Prepared by: Authorized by:

Andy Wang Softlines Department

Sherry Wang Softlines Department

Rechargeable Sealed Lead Acid Battery Safety Data Sheet according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations ( According to HCS-2012 APPENDIX D TO §1910.1200 ) Issue date: 2/24/2023 Revision date: 2/24/2023 Version: 1.0

2/24/2023 (Revision date) EN (English US) 1/14

SECTION 1: Identification

1.1. Identification

Product form : Article Trade name : Rechargeable Sealed Lead Acid Battery/Valve Regulated Lead Acid Battery/AGM Model No. : PS/PHR/PDC/PG/PSH/PG2V/PGFT/PSS/AGM-FA Series

1.2. Recommended use and restrictions on use

Recommended use : Industrial and General Purpose battery. Power supply Restrictions on use : No information available

1.3. Supplier

Power-Sonic Corporation 365 Cabela Dr. Suite 300 Reno, NV 89503 775-824-6500 puneet.kalia@power-sonic.com

1.4. Emergency telephone number

Emergency number : 1-800-222-1222

SECTION 2: Hazard(s) identification

2.1. Classification of the substance or mixture

GHS US classification Not classified

2.2. GHS Label elements, including precautionary statements

GHS US labeling No labeling applicable

2.3. Other hazards which do not result in classification

No additional information available

2.4. Unknown acute toxicity (GHS US)

No additional information available

SECTION 3: Composition/Information on ingredients

3.1. Substances

Not applicable

3.2. Mixtures

Name Product identifier % Lead CAS-No.: 7439-92-1 33 – 35 according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations ( According to HCS-2012 APPENDIX D TO §1910.1200 )

2/24/2023 (Revision date) EN (English US) 2/14

Name Product identifier % lead compound CAS-No.: / 33 – 35

Sulfuric acid CAS-No.: 7664-93-9 16-23

2-Propenenitrile, polymer with 1,3-butadiene and ethenylbenzene CAS-No.: 9003-56-9 3-7

Glass fiber separator CAS-No.: / 4-6

Tin CAS-No.: 7440-31-5 0.1 – 0.25

Calcium CAS-No.: 7440-70-2 0.04 – 0.11

Full text of hazard classes and H-statements : see section 16

SECTION 4: First-aid measures

4.1. Description of first aid measures

First-aid measures after inhalation : Not an expected route of exposure.

First-aid measures after skin contact : Wash skin with plenty of water.

First-aid measures after eye contact : Not an expected route of exposure.

First-aid measures after ingestion : Not an expected route of exposure. Call a poison center or a doctor if you feel unwell.

4.2. Most important symptoms and effects (acute and delayed)

No additional information available

4.3. Immediate medical attention and special treatment, if necessary

Treat symptomatically.

SECTION 5: Fire-fighting measures

5.1. Suitable (and unsuitable) extinguishing media

Suitable extinguishing media : Water spray. Dry powder. Foam.

Unsuitable extinguishing media : No information available.

5.2. Specific hazards arising from the chemical

Hazardous decomposition products in case of fire : Toxic fumes may be released.

5.3. Special protective equipment and precautions for fire-fighters

Firefighting instructions : Cool down the containers exposed to heat with a water spray. Do not allow run-off from fire fighting to enter drains or water courses. Eliminate every possible source of ignition. Approach from upwind. Ensure adequate ventilation, especially in confined areas. Evacuate personnel to a safe area. Avoid contact with skin and eyes.

Protection during firefighting : Do not attempt to take action without suitable protective equipment. Self-contained breathing apparatus. Complete protective clothing.

according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations ( According to HCS-2012 APPENDIX D TO §1910.1200 )

2/24/2023 (Revision date) EN (English US) 3/14

SECTION 6: Accidental release measures

6.1. Personal precautions, protective equipment and emergency procedures

6.1.1. For non-emergency personnel

Emergency procedures : Ventilate spillage area. Access forbidden to unauthorised personnel. Avoid contact with eyes, skin and clothing. Do not touch or walk on the spilled product. Eliminate all ignition sources if safe to do so. Ensure adequate ventilation, especially in confined areas. Evacuate personnel to a safe area. First aid personnel should wear appropriate protective equipment during any rescue.

Handle in accordance with good industrial hygiene and safety procedures. In case of fire: stop leak if safe to do so. Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Only qualified personnel equipped with suitable protective equipment may intervene. Prevent further leakage or spillage if safe to do so. Do not let product enter drains.

Discharge into the environment must be avoided. Remove all sources of ignition. Remove person to uncontaminated area. Stay upwind/keep distance from source. Take action to prevent static discharges. Use personal protective equipment as required.

6.1.2. For emergency responders

Protective equipment : Do not attempt to take action without suitable protective equipment. For further information refer to section 8: "Exposure controls/personal protection".

6.2. Environmental precautions

Avoid release to the environment.

6.3. Methods and material for containment and cleaning up

For containment : Collect spillage.

Methods for cleaning up : Mechanically recover the product. Absorb spillage to prevent material damage. Place in an appropriate container and dispose of the contaminated material at a licensed site. Absorb and/or contain spill with inert material (sand, vermiculite or other appropriate material), then place in suitable container. Collect all waste in suitable and labelled containers and dispose according to local legislation.

Other information : Dispose of materials or solid residues at an authorized site.

6.4. Reference to other sections

For further information refer to section 13.

SECTION 7: Handling and storage

7.1. Precautions for safe handling

Precautions for safe handling : Ensure good ventilation of the work station. Wear personal protective equipment. Do not open, destroy, or incinerate batteries because the battery may explode, break, or vent during these processes. Do not short-circuit the battery, overcharge, forced discharge or thrown into the fire.

Do not squeeze the battery or immerse the battery in the solution. Avoid contact with eyes, skin and clothing. Do not breathe gas/fumes/vapour/spray. Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Protect from heat and direct sunlight.

Hygiene measures : Do not eat, drink or smoke when using this product. Always wash hands after handling the product.

7.2. Conditions for safe storage, including any incompatibilities

Storage conditions : Avoid high temperatures. Keep away from heat and direct sunlight. Store in a dry, cool and well-ventilated place. Protect from moisture. Avoid shorting.

according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations ( According to HCS-2012 APPENDIX D TO §1910.1200 )

2/24/2023 (Revision date) EN (English US) 4/14

SECTION 8: Exposure controls/personal protection

8.1. Control parameters

Rechargeable Sealed Lead Acid Battery No additional information available

Lead (7439-92-1) USA - ACGIH - Occupational Exposure Limits

ACGIH OEL TWA 0.05 mg/m³

ACGIH chemical category Confirmed Animal Carcinogen with Unknown Relevance to Humans

USA - ACGIH - Biological Exposure Indices

BEI 200 μg/l Parameter: Lead - Medium: blood - Sampling time: not critical (Note: Persons applying this BEI are encouraged to counsel female workers of child-bearing age about the risk of delivering a child with a PbB (lead in blood level) over the current CDC reference value.)

USA - OSHA - Occupational Exposure Limits

OSHA PEL TWA [1] 50 µg/m³

USA - IDLH - Occupational Exposure Limits

IDLH 100 mg/m³

USA - NIOSH - Occupational Exposure Limits

NIOSH REL TWA 0.05 mg/m³

Sulfuric acid (7664-93-9) USA - ACGIH - Occupational Exposure Limits

ACGIH OEL TWA 0.2 mg/m³ (thoracic particulate matter)

ACGIH chemical category Suspected Human Carcinogen contained in strong inorganic acid mists

USA - OSHA - Occupational Exposure Limits

OSHA PEL TWA [1] 1 mg/m³

USA - IDLH - Occupational Exposure Limits

IDLH 15 mg/m³

USA - NIOSH - Occupational Exposure Limits

NIOSH REL TWA 1 mg/m³

2-Propenenitrile, polymer with 1,3-butadiene and ethenylbenzene (9003-56-9) No additional information available

Tin (7440-31-5) USA - ACGIH - Occupational Exposure Limits

ACGIH OEL TWA 2 mg/m³ (inhalable particulate matter)

USA - IDLH - Occupational Exposure Limits

IDLH 100 mg/m³

USA - NIOSH - Occupational Exposure Limits

NIOSH REL TWA 2 mg/m³ according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations ( According to HCS-2012 APPENDIX D TO §1910.1200 )

2/24/2023 (Revision date) EN (English US) 5/14

Calcium (7440-70-2) No additional information available

8.2. Appropriate engineering controls

Appropriate engineering controls : Ensure good ventilation of the work station.

Environmental exposure controls : Avoid release to the environment.

8.3. Individual protection measures/Personal protective equipment

Hand protection:

Protective gloves

Eye protection:

Not required

Skin and body protection:

Wear suitable protective clothing

Respiratory protection:

Not required

SECTION 9: Physical and chemical properties

9.1. Information on basic physical and chemical properties

Physical state : Solid Appearance : Grey/Blue/Black solid.

Colour : Grey/Blue/Black Odour : No data available Odour threshold : No data available pH : No data available Melting point : No data available Freezing point : No data available Boiling point : No data available Flash point : No data available Relative evaporation rate (butylacetate=1) : No data available Flammability (solid, gas) : Non flammable.

Vapour pressure : No data available Relative vapour density at 20 °C : No data available Relative density : No data available Solubility : No data available Partition coefficient n-octanol/water (Log Pow) : No data available Auto-ignition temperature : No data available Decomposition temperature : No data available Viscosity, kinematic : No data available Viscosity, dynamic : No data available Explosive limits : No data available Explosive properties : No data available

9.2. Other information

No additional information available according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations ( According to HCS-2012 APPENDIX D TO §1910.1200 )

2/24/2023 (Revision date) EN (English US) 6/14

SECTION 10: Stability and reactivity

10.1. Reactivity

The product is non-reactive under normal conditions of use, storage and transport.

10.2. Chemical stability

Stable under normal conditions.

10.3. Possibility of hazardous reactions

No dangerous reactions known under normal conditions of use.

10.4. Conditions to avoid

None under recommended storage and handling conditions (see section 7).

10.5. Incompatible materials

No additional information available

10.6. Hazardous decomposition products

Under normal conditions of storage and use, hazardous decomposition products should not be produced.

SECTION 11: Toxicological information

11.1. Information on toxicological effects

Acute toxicity (oral) : Not classified Acute toxicity (dermal) : Not classified Acute toxicity (inhalation) : Not classified

Sulfuric acid (7664-93-9) LD50 oral rat 2140 mg/kg

LC50 Inhalation - Rat 0.375 mg/l/4h

ATE US (oral) 2140 mg/kg body weight

ATE US (vapors) 0.375 mg/l/4h

ATE US (dust, mist) 0.375 mg/l/4h

Tin (7440-31-5) LD50 oral rat 700 mg/kg

LD50 dermal rat > 2000 mg/kg

LC50 Inhalation - Rat > 4.75 mg/l/4h

ATE US (oral) 700 mg/kg body weight

ATE US (dust, mist) 1.5 mg/l/4h

Skin corrosion/irritation : Not classified Serious eye damage/irritation : Not classified Respiratory or skin sensitization : Not classified Germ cell mutagenicity : Not classified Carcinogenicity : Not classified according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations ( According to HCS-2012 APPENDIX D TO §1910.1200 )

2/24/2023 (Revision date) EN (English US) 7/14

Lead (7439-92-1) IARC group 2A - Probably carcinogenic to humans

National Toxicity Program (NTP) Status Reasonably anticipated to be Human Carcinogen

In OSHA Hazard Communication Carcinogen list Yes

Sulfuric acid (7664-93-9) IARC group 1 - Carcinogenic to humans

National Toxicity Program (NTP) Status Known Human Carcinogens

In OSHA Hazard Communication Carcinogen list Yes

Reproductive toxicity : Not classified STOT-single exposure : Not classified STOT-repeated exposure : Not classified Aspiration hazard : Not classified Viscosity, kinematic : Not applicable

SECTION 12: Ecological information

12.1. Toxicity

Ecology - general : The product is not considered harmful to aquatic organisms or to cause long-term adverse effects in the environment.

Lead (7439-92-1) LC50 - Fish [1] 0.44 mg/l (Exposure time: 96 h - Species: Cyprinus carpio [semi-static])

EC50 - Crustacea [1] 600 μg/l (Exposure time: 48 h - Species: water flea)

LC50 - Fish [2] 1.17 mg/l (Exposure time: 96 h - Species: Oncorhynchus mykiss [flow-through])

Sulfuric acid (7664-93-9) LC50 - Fish [1] > 500 mg/l (Exposure time: 96 h - Species: Brachydanio rerio [static])

12.2. Persistence and degradability

No additional information available

12.3. Bioaccumulative potential

Sulfuric acid (7664-93-9) BCF - Fish [1] (no bioaccumulation)

12.4. Mobility in soil

No additional information available

12.5. Other adverse effects

No additional information available according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations ( According to HCS-2012 APPENDIX D TO §1910.1200 )

2/24/2023 (Revision date) EN (English US) 8/14

SECTION 13: Disposal considerations

13.1. Disposal methods

Waste treatment methods : Dispose of contents/container in accordance with licensed collector’s sorting instructions.

Destroy the product by incineration (in accordance with local and national regulations).

Contaminated packaging : Dispose of contents/container in accordance with licensed collector’s sorting instructions.

Destroy packaging by incineration at an approved waste disposal site. In accordance with local and national regulations.

SECTION 14: Transport information

In accordance with DOT / TDG / IMDG / IATA

14.1. UN number

DOT NA No : UN2800 UN-No. (TDG) : UN2800 UN-No. (IMDG) : 2800 UN-No. (IATA) : 2800

14.2. UN proper shipping name

Proper Shipping Name (DOT) : Batteries, wet, non-spillable Proper Shipping Name (TDG) : BATTERIES, WET, NON-SPILLABLE Proper Shipping Name (IMDG) : BATTERIES, WET, NON-SPILLABLE Proper Shipping Name (IATA) : Batteries, wet, non-spillable

14.3. Transport hazard class(es)

DOT

Transport hazard class(es) (DOT) : 8 Hazard labels (DOT) : 8

TDG

Transport hazard class(es) (TDG) : 8 Hazard labels (TDG) : 8

IMDG

Transport hazard class(es) (IMDG) : 8 Hazard labels (IMDG) : 8

IATA

Transport hazard class(es) (IATA) : 8 according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations ( According to HCS-2012 APPENDIX D TO §1910.1200 )

2/24/2023 (Revision date) EN (English US) 9/14

Hazard labels (IATA) : 8

14.4. Packing group

Packing group (DOT) : Not applicable Packing group (TDG) : Not applicable Packing group (IMDG) : Not applicable Packing group (IATA) : Not applicable

14.5. Environmental hazards

Other information : No supplementary information available.

14.6. Special precautions for user

DOT

UN-No.(DOT) : UN2800 DOT Packaging Exceptions (49 CFR 173.xxx) : 159a DOT Packaging Non Bulk (49 CFR 173.xxx) : 159 DOT Packaging Bulk (49 CFR 173.xxx) : 159 DOT Quantity Limitations Passenger aircraft/rail (49

CFR 173.27)

: No Limit

DOT Quantity Limitations Cargo aircraft only (49

CFR 175.75)

: No Limit

DOT Vessel Stowage Location : A - The material may be stowed ‘‘on deck’’ or ‘‘under deck’’ on a cargo vessel and on a passenger vessel.

TDG

UN-No. (TDG) : UN2800 TDG Special Provisions : 39 - (1) These dangerous goods may be handled, offered for transport or transported under this shipping name if the dangerous goods are

(a) protected from short circuits; and

(b) capable of withstanding, without leakage of battery fluid, the following tests:

(i) a vibration test, in which

(A) the battery is rigidly clamped to the platform of a vibration machine and a simple harmonic motion having an amplitude of 0.8 mm (1.6 mm maximum total excursion) is applied,

(B) the frequency is varied in steps of 1 Hz each minute between the limits of 10 Hz and 55 Hz,

(C) the entire range of frequencies and return is traversed in 95 ± 5 minutes with 2 minutes spent at each frequency for each mounting position (direction of vibration) of the battery, and

(D) the battery is tested in three mutually perpendicular positions (to include testing with fill openings and vents, if any, in an inverted position) for equal time periods, and

(ii) after the vibration test, a pressure differential test, in which

(A) the battery is stored for 6 hours at 24°C ± 4°C while subjected to a pressure differential greater than or equal to 88 kPa, and

(B) the battery is tested in three mutually perpendicular positions (to include testing with fill openings and vents, if any, in an inverted position) for at least 6 hours in each position.

(2) These Regulations, except for Part 1 (Coming into Force, Repeal, Interpretation, General Provisions and Special Cases) and Part 2 (Classification), do not apply to UN2800, BATTERIES, WET, NON-SPILLABLE, electric storage, that are not intended for disposal, if

(a) at a temperature of 55°C, electrolyte will not flow from a ruptured or cracked battery case and there is no free liquid to flow; and

(b) when the battery is prepared for transport, the battery’s terminals are protected from short circuits.

Explosive Limit and Limited Quantity Index : 1 L Excepted quantities (TDG) : E0 according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations ( According to HCS-2012 APPENDIX D TO §1910.1200 )

2/24/2023 (Revision date) EN (English US) 10/14

Emergency Response Guide (ERG) Number : 154

IMDG

Special provision (IMDG) : 238 Limited quantities (IMDG) : 1 L Excepted quantities (IMDG) : E0 Packing instructions (IMDG) : P003 Packing provisions (IMDG) : PP16 EmS-No. (Fire) : F-A - FIRE SCHEDULE Alfa - GENERAL FIRE SCHEDULE EmS-No. (Spillage) : S-B - SPILLAGE SCHEDULE Bravo - CORROSIVE SUBSTANCES Stowage category (IMDG) : A Properties and observations (IMDG) : Metal plates immersed in gelled alkaline or acid electrolyte in a glass, hard rubber or plastics receptacle of a non-spillable type. When electrically charged, may cause fire through short-circuiting of terminals. Cause burns to skin, eyes and mucous membranes.

IATA

PCA Excepted quantities (IATA) : E0 PCA Limited quantities (IATA) : Forbidden PCA limited quantity max net quantity (IATA) : Forbidden PCA packing instructions (IATA) : 872 PCA max net quantity (IATA) : No limit CAO packing instructions (IATA) : 872 CAO max net quantity (IATA) : No limit Special provision (IATA) : A48, A67, A164, A183 ERG code (IATA) : 8L

14.7. Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code

Not applicable

SECTION 15: Regulatory information

15.1. US Federal regulations

Commercial status of components according to the United States Environmental Protection Agency’s Toxic Substances Control Act (TSCA):

Name CAS-No. Listing Commercial status

Flags

Lead 7439-92-1 Present Active

Sulfuric acid 7664-93-9 Present Active

2-Propenenitrile, polymer with 1,3-butadiene and ethenylbenzene

9003-56-9 Present Active XU

Tin 7440-31-5 Present Active

Calcium 7440-70-2 Present Active

Lead (7439-92-1) Subject to reporting requirements of United States SARA Section 313

CERCLA RQ 10 lb no reporting of releases of this hazardous substance is required if the diameter of the pieces of the solid metal released is >100 µm

Sulfuric acid (7664-93-9) Subject to reporting requirements of United States SARA Section 313

CERCLA RQ 1000 lb according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations ( According to HCS-2012 APPENDIX D TO §1910.1200 )

2/24/2023 (Revision date) EN (English US) 11/14

Sulfuric acid (7664-93-9) RQ (Reportable quantity, section 304 of EPA's List of Lists)

1000 lb

Section 302 EPCRA Reportable Quantity (RQ) 1000 lb

SARA Section 302 Threshold Planning Quantity

(TPQ)

1000 lb

15.2. International regulations

CANADA

Lead (7439-92-1) Listed on the Canadian DSL (Domestic Substances List)

Toxic Substance (CEPA – Schedule I) Yes

Sulfuric acid (7664-93-9) Listed on the Canadian DSL (Domestic Substances List)

2-Propenenitrile, polymer with 1,3-butadiene and ethenylbenzene (9003-56-9) Listed on the Canadian DSL (Domestic Substances List)

Tin (7440-31-5) Listed on the Canadian DSL (Domestic Substances List)

Calcium (7440-70-2) Listed on the Canadian DSL (Domestic Substances List)

EU-Regulations

Lead (7439-92-1) Listed on the EEC inventory EINECS (European Inventory of Existing Commercial Chemical Substances)

Sulfuric acid (7664-93-9) Listed on the EEC inventory EINECS (European Inventory of Existing Commercial Chemical Substances)

Tin (7440-31-5) Listed on the EEC inventory EINECS (European Inventory of Existing Commercial Chemical Substances)

Calcium (7440-70-2) Listed on the EEC inventory EINECS (European Inventory of Existing Commercial Chemical Substances) according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations ( According to HCS-2012 APPENDIX D TO §1910.1200 )

2/24/2023 (Revision date) EN (English US) 12/14

National regulations

Lead (7439-92-1) Listed on IARC (International Agency for Research on Cancer) Listed introduction on Australian Industrial Chemicals Introduction Scheme (AICIS Inventory) Listed on PICCS (Philippines Inventory of Chemicals and Chemical Substances) Listed on the Japanese ENCS (Existing New Chemical Substances) inventory Listed on KECL/KECI (Korean Existing Chemicals Inventory) Listed on IECSC (Inventory of Existing Chemical Substances Produced or Imported in China) Japanese Pollutant Release and Transfer Register Law (PRTR Law) Listed on NZIoC (New Zealand Inventory of Chemicals) Listed on INSQ (Mexican National Inventory of Chemical Substances) Listed on the TCSI (Taiwan Chemical Substance Inventory) Listed on the NCI (Vietnam - National Chemical Inventory)

Sulfuric acid (7664-93-9) Listed on IARC (International Agency for Research on Cancer) Listed as carcinogen on NTP (National Toxicology Program) Listed introduction on Australian Industrial Chemicals Introduction Scheme (AICIS Inventory) Listed on PICCS (Philippines Inventory of Chemicals and Chemical Substances) Listed on the Japanese ENCS (Existing New Chemical Substances) inventory Listed on KECL/KECI (Korean Existing Chemicals Inventory) Listed on IECSC (Inventory of Existing Chemical Substances Produced or Imported in China) Japanese Poisonous and Deleterious Substances Control Law Listed on NZIoC (New Zealand Inventory of Chemicals) Listed on the Japanese ISHL (Industrial Safety and Health Law) Listed on INSQ (Mexican National Inventory of Chemical Substances) Listed on the TCSI (Taiwan Chemical Substance Inventory) Listed on the NCI (Vietnam - National Chemical Inventory)

2-Propenenitrile, polymer with 1,3-butadiene and ethenylbenzene (9003-56-9) Listed introduction on Australian Industrial Chemicals Introduction Scheme (AICIS Inventory) Listed on PICCS (Philippines Inventory of Chemicals and Chemical Substances) Listed on the Japanese ENCS (Existing New Chemical Substances) inventory Listed on KECL/KECI (Korean Existing Chemicals Inventory) Listed on IECSC (Inventory of Existing Chemical Substances Produced or Imported in China) Listed on NZIoC (New Zealand Inventory of Chemicals) Listed on the Japanese ISHL (Industrial Safety and Health Law) Listed on INSQ (Mexican National Inventory of Chemical Substances) Listed on the TCSI (Taiwan Chemical Substance Inventory) Listed on the NCI (Vietnam - National Chemical Inventory)

Tin (7440-31-5) Listed introduction on Australian Industrial Chemicals Introduction Scheme (AICIS Inventory) Listed on PICCS (Philippines Inventory of Chemicals and Chemical Substances) Listed on the Japanese ENCS (Existing New Chemical Substances) inventory Listed on KECL/KECI (Korean Existing Chemicals Inventory) Listed on IECSC (Inventory of Existing Chemical Substances Produced or Imported in China) Listed on NZIoC (New Zealand Inventory of Chemicals) Listed on INSQ (Mexican National Inventory of Chemical Substances) Listed on the TCSI (Taiwan Chemical Substance Inventory) Listed on the NCI (Vietnam - National Chemical Inventory) according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations ( According to HCS-2012 APPENDIX D TO §1910.1200 )

2/24/2023 (Revision date) EN (English US) 13/14

Calcium (7440-70-2) Listed introduction on Australian Industrial Chemicals Introduction Scheme (AICIS Inventory) Listed on PICCS (Philippines Inventory of Chemicals and Chemical Substances) Listed on the Japanese ENCS (Existing New Chemical Substances) inventory Listed on KECL/KECI (Korean Existing Chemicals Inventory) Listed on IECSC (Inventory of Existing Chemical Substances Produced or Imported in China) Listed on NZIoC (New Zealand Inventory of Chemicals) Listed on INSQ (Mexican National Inventory of Chemical Substances) Listed on the TCSI (Taiwan Chemical Substance Inventory) Listed on the NCI (Vietnam - National Chemical Inventory)

15.3. US State regulations

Lead (7439-92-1) U.S. - California - Proposition 65 - Carcinogens List

U.S. - California - Proposition 65 - Developmental Toxicity

U.S. - California - Proposition 65 - Reproductive Toxicity

- Female

U.S. - California - Proposition 65 - Reproductive Toxicity

- Male

No significant risk level (NSRL)

Maximum allowable dose level (MADL)

Yes Yes Yes Yes 15 µg/day (oral) 0.5 µg/day

SECTION 16: Other information according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations ( According to HCS-2012 APPENDIX D TO §1910.1200 ) Issue date : 2/24/2023 Revision date : 2/24/2023 Data sources : Loli. ECHA reference.

Training advice : Normal use of this product shall imply use in accordance with the instructions on the packaging.

Abbreviations and acronyms

ADN European Agreement concerning the International Carriage of Dangerous Goods by Inland Waterways

ADR Agreement concerning the International Carriage of Dangerous Goods by Road

ATE Acute Toxicity Estimate

BCF Bioconcentration factor

BLV Biological limit value

BOD Biochemical oxygen demand (BOD)

COD Chemical oxygen demand (COD)

DMEL Derived Minimal Effect level

DNEL Derived-No Effect Level

EC-No. European Community number

EC50 Median effective concentration

EN European Standard

IARC International Agency for Research on Cancer

IATA International Air Transport Association

IMDG International Maritime Dangerous Goods according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations ( According to HCS-2012 APPENDIX D TO §1910.1200 )

2/24/2023 (Revision date) EN (English US) 14/14

Abbreviations and acronyms

LC50 Median lethal concentration

LD50 Median lethal dose

LOAEL Lowest Observed Adverse Effect Level

NOAEC No-Observed Adverse Effect Concentration

NOAEL No-Observed Adverse Effect Level

NOEC No-Observed Effect Concentration

OECD Organisation for Economic Co-operation and Development

OEL Occupational Exposure Limit

PBT Persistent Bioaccumulative Toxic

PNEC Predicted No-Effect Concentration

RID Regulations concerning the International Carriage of Dangerous Goods by Rail

SDS Safety Data Sheet

STP Sewage treatment plant

ThOD Theoretical oxygen demand (ThOD)

TLM Median Tolerance Limit

VOC Volatile Organic Compounds

CAS-No. Chemical Abstract Service number

N.O.S. Not Otherwise Specified vPvB Very Persistent and Very Bioaccumulative

ED Endocrine disrupting properties

Indication of changes:

Not applicable.

Safety Data Sheet (SDS), USA

This information is based on our current knowledge and is intended to describe the product for the purposes of health, safety and environmental requirements only. It should not therefore be construed as guaranteeing any specific property of the product.

dark_signature_error:
signature_error:
2023-03-08T09:47:57+0800
中国
文档加密保护

File details come from the government source that posted it. Updated .