PN 568-20-102 JA - JCI (Redacted) (4 pages).pdf

PDF 344 KB Posted

Attached to
Z1DA--PN: 568-20-102 Upgrade Mental Health Lock Ward (FM)
Solicitation number
36C26323B0001
Issued by

About this file

This justification and approval document requests sole source procurement from Johnson Controls International for building automation system devices, fire alarm devices, and PIV card readers for a construction project at the Department of Veterans Affairs Fort Meade VA Medical Center. The project aims to upgrade the mental health lock ward and construct a new mechanical penthouse. Johnson Controls International is deemed the only responsible source because their systems are the standards already installed and integrated at the facility, utilizing proprietary technologies not compatible with other vendors. Maintaining compatibility is necessary for patient safety, climate control, fire protection, and security. The total estimated costs for the sole source requirements are provided. The overall construction project will be competitively solicited as a 100% service-disabled veteran-owned small business set-aside with a firm-fixed price contract.

View the file

Other files

Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Part 806.3 Other Than Full and Open Competition (OFOC) Attachment 7: Request for Sole Source Justification Format >SAT

DEPARTMENT OF VETERANS AFFAIRS

Justification and Approval (J&A) For Other Than Full and Open Competition (>SAT)

Acquisition Plan Action ID: 36C263-23-AP-0828

1. Contracting Activity: Department of Veterans Affairs, Network Contracting Office 23 (NCO23), VA

Black Hills Health Care System (VABHHCS), Fort Meade VA Medical Center, Facilities Management Engineering Department, 113 Comanche Road, Fort Meade, SD 57741. VA Purchase Request Form 2237 number is 568-23-1-9965-0006.

2. Nature and/or Description of the Action Being Processed: A new construction project that has a need for brand-named sole source items from Johnson Controls International (JCI) – Building Automation System (BAS) devices and programming, fire alarm devices and programming, and PIV card readers for door access controls and programming. These are partial requirements for Project 568-20-102 Upgrade Mental Health Lock Ward which the contractor shall renovate the mental health lock ward of Building 148. This project will raise the ceiling in the lock ward. This project will construct a penthouse for the new mechanical equipment displaced by the ceiling raise. The overall construction project will be solicited in a competitive environment as a 100% Service-Disabled Veteran-Owned Small Business set-aside and will be awarded as a Firm-Fixed Price contract.

3. Description of Supplies/Services Required to Meet the Agency’s Needs: As part of this partial requirement, the contractor shall provide BAS devices and services such as DDC 75 points and controls to the replacement HVAC equipment within the project, training to employees as needed on the system, integration with the existing system, and provide test controls systems at the completion of the contract. The estimated costs for the BAS requirements of the project is

As part of this partial requirement, the contractor shall provide fire alarm devices such as smoke detectors, heat detectors, alarm stations, visual and audio alarms, water flow switches, and smoke/fire door closures and programming to the existing system. The estimated costs for the Simplex Fire Alarm System devices and programming is

As part of this partial requirement, the contractor shall provide PIV card readers and programming to the existing system. The estimated costs for the PIV door access card readers and programming is

The total costs for this Justification and Approval for JCI to provide the requirements for the BAS, fire alarm system and door access controls is

4. Statutory Authority Permitting Other than Full and Open Competition:

( X ) (1) Only One Responsible Source and No Other Supplies or Services Will Satisfy Agency Requirements per 41 USC §3304(a)(1) as implemented by FAR 6.302-1

5. Demonstration that the Contractor’s Unique Qualifications or Nature of the Acquisition Requires the Use of the Authority Cited Above (applicability of authority): The specified building automation system is the only system meeting the requirements of the Fort Meade VA Medical Center. The intent is to install the same brand and type of building automation system throughout the medical center to provide a system that is compatible with the existing system. JCI is used throughout the facility for all temperature control needs which is managed via the BAS. The current Johnson Controls Building Automation System utilizes proprietary technology so other systems are not able to connect to it. As part of this requirement, the contractor shall provide DDC 75 points and controls to the HVAC equipment within the project, training to employees as needed on the system, integration with the existing system, and provide test controls systems at the completion of the contract. The medical center has standardized on this system to improve patient safety, building temperature comfort, temperature alarms/alerts, and reduce maintenance and training costs.

Patient comfort and safety would be at risk if a patch work of climate controls systems were installed in any facility that already has Johnson controls. Lack of a standardized system would impact the facilities ability to maintain proper climate control.

The specified fire alarm system is the only system that can meet the requirements of the Fort Meade VA Medical Center. The intent is to install the same brand and type of fire alarm system throughout the medical center to provide a system that is compatible with the existing system. The JCI Simplex System is used throughout the facility for all fire alarm functions. The current JCI Simplex fire system utilizes proprietary technology so other systems are not able to connect to it. The medical center has standardized on this system to improve patient and building safety and reduce maintenance and training costs. The requirement of this project would add fire alarm devices such as smoke detectors, heat detectors, alarm stations, visual and audio alarms, water flow switches, and smoke/fire door closures all of which must communicate and function with the existing system to prove full fire protection of the facility. Patient, employee, and building safety would be at risk if a different fire alarm system was installed as there would be a risk of non-communication between the devices. Lack of a standardized system would impact the facilities ability to maintain fire safety standards.

The specified JCI door access PIV card readers are the only door controls that can meet the requirements of the Fort Meade VA Medical Center. The intent is to install the same brand and type of PIV card readers throughout the medical center to provide a system that is compatible with the existing system. The JCI PIV card readers are used throughout the entire facility for all door access controls. The current JCI PIV door access control system utilizes proprietary technology so other systems are not able to connect to it. The medical center has standardized on this system to improve patient and building safety and reduce maintenance and training costs. The requirement of this project would add PIV card readers for specified doors all of which must be programmed to communicate and function with the existing system. Patient, employee, and building safety would be at risk if a different door access system was installed as there would be a risk of non-communication between the devices and could cause security breaches within the facility. Lack of a standardized system would impact the facilities ability to maintain the security space/building standards.

Accordingly, JCI is the only firm capable of providing the supplies and services described In Section III above without the Veteran’s Health Administration and Fort Meade VA Medical Center experiencing substantial duplication of cost that could not be expected to be recovered through competition. In addition, JCI is the only firm capable of providing the supplies and services described in Section III above without the Veteran’s Health Adminsition and Fort Meade VA Medical Center experiencing substantial risks to patient care, safety of patients and employees, and complete building security and safety.

6. Description of Efforts Made to ensure that offers are solicited from as many potential sources as deemed practicable: The overall construction project will be solicited in a competitive environment as a 100% Service-Disabled Veteran-Owned Small Business set-aside and will be awarded as a Firm- Fixed Price contract; however, the supplies and services needed under this Justification and Approval will be sourced from JCI. All of the JCI systems as mentioned was previously competed under separate requirements and are considered major systems for the Fort Meade VA Medical Center. The current JCI systems contains and utilizes proprietary technology and data so other systems are not able to connect to the existing systems.

7. Determination by the CO that the Anticipated Cost to the Government will be Fair and

Reasonable: It is anticipated that the overall project costs from the lowest priced offer will be considered fair and reasonable based upon competition, comparison with the Independent Government Cost Estimate (IGCE), and current market conditions for like or similar work.

In order to assist with a price fair and reasonableness determination other than that mentioned above, the Contracting Officer may require the contractors to provide a further price breakdown of these components and systems for additional price analysis.

8. Description of the Market Research Conducted and the Results, or a Statement of the Reasons

Market Research Was Not Conducted: Market research was conducted prior to selecting this manufacturer as the facilities standard base for these major systems. This justification is specific to the manufacturer, Johnson Controls International. Separate projects for facility-wide systems to include the building automation system, fire protection system, and door access controls system was competed with JCI being selected. These partial requirements of this project is a minor extension of the existing systems. At this time there are no competing vendors whose products are fully compatible with the existing systems; however, if devices or systems other than Johnson Controls is found to have the capability to communicate and maintain the integrity of each of the referenced systems then it will be considered acceptable. None to date is known or shown to be available.

9. Any Other Facts Supporting the Use of Other than Full and Open Competition: Alternate systems were considered during design of the project; however, the results indicated that these systems contain proprietary technology and data and no other vendors were able to provide the supplies and services to be compatible with the existing systems. Because of these results, the construction documents to include the specifications, drawings, and statement of work only allows for JCI because no other supplies or services from another vendor is available.

10. Listing of Sources that Expressed, in Writing, an Interest in the Acquisition: None

11. A Statement of the Actions, if any, the Agency May Take to Remove or Overcome any Barriers to

Competition before Making subsequent acquisitions for the supplies or services required: If in the future, another vendor other than Johnson Controls is found to have the capability to communicate and maintain the integrity of each of the referenced systems then it will be considered acceptable.

In addition, if in the future the facility has the need to develop and install new systems in their entirety, competition would be considered for the requirement.

12. Requirements Certification: I certify that the requirement outlined in this justification is a Bona Fide Need of the Department of Veterans Affairs and that the supporting data under my cognizance, which are included in the justification, are accurate and complete to the best of my knowledge and belief.

Justin Whitehead Date Engineering Program Manager VABHHCS, Fort Meade, SD

13. Approvals in accordance with the VHAPM Part 806.3 OFOC SOP:

a. Contracting Officer or Designee’s Certification (required): I certify that the foregoing justification is accurate and complete to the best of my knowledge and belief.

Angie Mabley Date Contracting Officer Network Contracting Office 23

b. One Level Above the Contracting Officer (Required over SAT but not exceeding $750K): I certify the justification meets requirements for other than full and open competition.

Gregg Sutcliffe Date NCO 23 Branch Chief

02/06/2023

VHADESMableA Typewritten Text 2/6/2023

2023-02-06T08:41:40-0700
JUSTIN WHITEHEAD
2023-02-06T11:44:15-0600
Angelique D. Mabley 306316